Loading...
HomeMy WebLinkAboutpitkin.eh.264323100002 (2004) (Ranch Mgr House - Historic Cabin)Pitkin County Environmental Health Department Permit for an Individual Sewage Disposal System 0405 Castle Creek Road, Suite 10, Aspen, Colorado 81611 Phone 970-920-5070 / FAX 970-920-5077 Permit # 04057 Parcel ID # 2643-231-00-001 Ranch Manager House & Historic Cabin Type of permit New( ) Repair( ) Addition/Remodel to House( X) — Upgrading Septic System Only Name of Owner George Stranahan — Flying Dog Ranch Street Address 3069 Woody Creek Rd Property legal description Size of lot 232 acres Total square footage of the house 2960 Ranch Manager Water source Existing Private Well # of bedrooms in house 5 # of offices, lofts & similar sized rooms in house tc; Caretaker unit 944 Total square footage of the caretaker unit �7— ' # of bedrooms in caretaker unit 2 # of offices, lofts &similar sized rooms in caretaker unit t ,& Designed for what # rooms (list) SEVEN (7) Bedrooms: 5 in Ranch Manager House + 2 in Historic Cabin Designed by Mailing Address Perc rate 9 Permit information Timberline Engineering PO Box 631. Carbondale, CO 81623 Profile hole depth Minimum Septic tank capacity 2187 & 750 9-1/2 ft Depth to groundwater or bedrock Minimum Absorption area Comments > 9-1/2 ft 1365 sq ft/ 30%reduc=956 Septic permit approved per compliance with the engineer design and specifications dated revised 7/19/04. Any changes must be approved by this department and the design engineer prior to them being made. Minimum horizontal distances between components of the system and physical features shall conform to the Pitkin County ISDS regulations. The design is to use the existing 1,000 gallon septic tank for the Historic Cabin and add an effluent filter to the outlet. The Ranch Manager House will use the existing 1,000 gallon septic tank and a second 1,500 gallon concrete tank will be added in series. An effluent filter is required on the outlet of the second tank. Effluent will be piped under the county road to a common gravelless chamber bed 7 chambers wide by 9 chambers long. This department does not endorse any brand of products. This permit must be kept on-site during installation. The engineer must do a final inspection of the installation and submit an as -built letter to this department. This department must also be called for an inspection with a minimum of 48 hours advanced notice. 'Revegetation over the area of the field is very important for the functioning of the system. Pitkin County has guidelines that must be followed to assure the plants that are introduced are appropriate for the conditions of the area. The use of native plants is strongly encouraged. Permit approved by: �� 1 / , ae Date:'Z// /c'7 Plans and specifications of the proposed individual sewage disposal system have been reviewed and are considered satisfactory. Permission is hereby granted to the owner or the agent to perform the work indicated in accordance with the Pitkin County ISDS Regulation in effect at the time of issue. This permit becomes invalid 6 months from the date that the permit was issued unless system construction has commenced or an extension has been approved in writing by the Department. As -built drawings must be included with this permit before the final approval will be issued. Installer: r/ t Final approval: a &'c A..tc Date: PITKIN COUNTY ENVIRONMENTAL HEALTH DEPARTMENT APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM 0405 Caste e hone (9 ) 920_5070 Fax 9 10, 0 Colorado 8j611 920-5077 Name of OWNER Owner's Mailing Address 115-7c b Home Phone: �O Primary Contact Person (all communication regarding this permit tl M go through this person) t � �o^a+l cox: �� (s bU t�rrlauHWrGw• C e I I Phone : ?� Parcel ID a (available from assessor's office 2 j-- �---� ZL at 920-5160 or at www DitklnaSSeSs r.Orrt) Street address of property _� bc� ,Block .Fine ,Subdivision Legal Description: — Sze of rot: Z acrpes• Type of proposed stricture: l ✓'C1 Total square feet of house 1 26"T ft of bedrooms (potential) in house Caretaker Unit: Attached ( ) Detached ( Permit is for New Home ( ) Repair due to failure ( ) Remt' odellAddition (X EST � se ( } t Priv>Q Weil( ) Spring ( Stream ( ) CommunityiPublic Water System ( ) if community system: Name of system department to rove. if approval takes The fee for a SSDS apPlication is $600 for r will a that takes 6 hours m less for the00.ThbaeP longer than 6 Fours, a rate of $100 per hour will be charged. The firstum fee is at the time o suanceao basic ISD Permit second, time of application. The reminder, If any, will be due in two stages before final approval of the ISDS permit. Application for an individual sewage disposal system is hereby submitted. I hereby certify that the above informalion is true and accurate and that i have provided tete and accurate irdorrnalan on locations of all existing and Proposed wells, contour suction or irrigation lines, drinking water cisterns, drain Intervals, buildings, Property lines. ditches. slopes, waterlines, springs, systems. 1 hereby certify hies, irrigation ditches, takes, water courses, streams, floodplain, dry gulches, and exlseng septic Y the appal of that any such features not shown on attached site Pursuant Pin Conot punry codes. Nom otonstrudion may be u f the permit does ot>dertaken �'l as any other permit required for construction approvals and permits have been obtained. Pitkin County and employees of these agencies will be held harmless The Pitkin County Environmental Health Department,permit to construct is issued on inforrnation submitted by should the individual sewage disposal system fail or m2ffundion• In Case pt is iss of the system. the applignt or his/her representatives. The owner assumes full r�jpobiffitY Signature of ap Received by �^ Date Receipt #� Date S ,NGT G:iisdslisds applimisdsapp RevW0iO3.d0c G I WA_ PJFM_ __ __ Carla Block, 12:53 PM 9/23/2004. etranahan X -Sender: carlab@commons X -Mailer: QUALCOMM Windows Eudora Pro Version 4.2.0.58 Date: Thu, 23 Sep 2004 12:53:52 -0600 To: Nancy MacKenzie <nancym@ci.aspen.co.us> From: Carla Block <carlab@ci.aspen.co.us> Subject: stranahan X-MailScanner-Information: Please contact the ISP for more information X-MailScanner: Found to be clean Page 1 of 1 Jeff Gerbaz called about the straw bail house. He said he didn't see that the engineer has speced the EQ - 36 until he had already ordered the standard. I told him they were both so close, he should call the engineer to see of there was any other REASON he called for the EQ 36, but he is out of town. He will use between 14-16 standard units. I also think he said they may have room for one row. I also noticed in playing with the numbers that on the calcs, #4, he using 9 1/2? instead of 12 for the perc rate. Maybe I'm not seeing something. He also used 15.5 instead of 15.965, which in the big picture I don't think will matter at all. But I think it's strange that he called for EQ- 36 but did sizing for standard and it seems he figured square footage wrong. cb Carla Block Pitkin County Environmental Health 970-920-5438 Printed for Nancy MacKenzie <nancym@co.pitkin.co.us> 9/24/2004 L7i jima@co.pitkin.co.us, vicldm@co.pitkin.co.us, tonyf@co.pitkin.c, 04:54 PM 12/6/2004, CO okay: Flying Dol To: jima@co.pitkin.co.us, vickim@co.pitkin.co.us, tonyf@co.pitkin.co.us, debbiew@co.pitkin.co.us, stephd@co.pitkin.co.us From: Nancy MacKenzie <nancym@co.pitkin.co.us> Subject: CO okay: Flying Dog Ranch 3069 Woody Creek Rd Cc: Bcc: Attached: The septics have been given final approval for both the STRAWBALE HOUSE, MAIN RESIDENCE, & RANCH MANAGER HOUSE/HISTORIC CABIN. So it is okay to give them CO's on all the buildings. The old 'bunkhouse' had all plumbing and sewer connection removed, so we have no concerns with that structure. Printed for Nancy MacKenzie <nancym@co.pitkin.co.us> 11 :www I E=J E SII ,FF.' i S'll'RUQ;7CURAIL/cCP1 qL IENGIK]E]ERWG ♦ cC®1`lTRA C'I('WG ♦ (CIER'll')1)F) D ENERGY Y DESIGN PRO FIESSEGNAIL December 1, 2004 Pitkin County Environmental Health 0405 Castle Creek Road, Suite 10 Aspen, Colorado 81611 Re: ISDS Installation Flying Dog Ranch Main Residence Dear Environmental Health: The ISDS for the above residence has been inspected and is in proper operating condition. The bunkhouse that was attached to this system has been eliminated from the system by removing the plumbing inside the bunkhouse and plugging the sewer line with concrete. An effluent filter was not installed due to the difficulty in accessing the existing tanks and not being able to retrofit the effluent pump with a filter. If you have any questions, please call me at 963-9869. Sincerely, David A. Powe] Reg. No. 25851 P.O. BOX 63t cCA BONDAILIE, CO. 81623 PHONE E 970 963 9869 / FAX 970 963 9003 FROM FAX NO. De 02 2003 08:23AM PI 12-2-2004 Dave Timberline Engineering, 1 filled the drain at the Stranahan Bunk House with cooCrete, as requested by Nancy at Community Health Services. Doug Carpenter Lenado Construction S'll RUC II URAL/cCIVU- FNGUJEERWG ♦ CGNTPACT (3 ♦ CIER7I'IDF'IDED IENIERcGY DIESEG14 PRO FIESSE014AIL November 18, 2004 Pitkin County Environmental Health 0405 Castle Creek Road, Suite 10 Aspen, Colorado 81611 Re: ISDS Installation Flying Dog Ranch Strawbale Residence Dear Environmental Health: NOS, 2 3 2004 P1iKlN i NEA1-TM EM1tiRONMEt� The installation of the ISDS for the above residence has been completed and has been installed in accordance with applicable county specifications and the approved plan with the exception of the type of infiltrator unit. The units were changed to the H-10 style and the quantity was changed per a conversation the contractor, Stutsman-Gerbaz, had with your department and your recommendations for the new quantity. Revised calculations are shown on the as -built plan. Enclosed is the as -built drawing for the system. If you have any questions, please call me at 963-9869. Sincer , i David A. Powell, PE Reg. No. 25851 o�d�g�04 P.O. BOX 631 CARB®NDAIL.IE, CO. K623 PHONE 970 963 9869 / FAX 970 963 9003 PITKIN ENVIRONMENTAL HEALTH DEPARTMENT �) ISDS DESIGN CALCULATIONS Owner's Name Parcel ID # House Size (sq. ft.) (75 gpd, 100 gpd, or 130 gpd) Number of Bedrooms in Main House Number of Offices, Libraries, Studies, Similar -sized Rooms in Main House Number of Bedrooms in Detached Caretaker unit Number of Offices, Studies, Similar -sized Rooms in Caretaker Unit (If the caretaker unit is ATTACHED, treat as if part of main house.) Average Daily Waste Flow 0 State Review Required? no Perc Rate 12 (T) Design Flow (Q) = # potential bedrooms X 2 people/ bedroom X gpd X 1.75 Q= 703 - Minimum tank capacity gallons Absorption Area (=Q/5 X SQRT perc rate) A = 487.05269 sq. ft. of absorption area required 6 31 gravelless chamber units without reduction # of Perc Holes Required: 3 1 in every soil type? Spaced uniformly over proposed area? A maximum: 50% only if the lot size and soil conditions are optimal. If a reduction is being proposed, describe why lot size and soil conditions are optimal: A = 243.52634 sq.ft. with 50% reductionTRENCHES 340.93688 sq ft 30% reduction BED 16 gravelless chamber units with reduction chamber units with reduc. Type of system: []Absorption trenches []Absorption bed [] Gravelless chambers []Dry well []Seepage Pit []Other (type) SETBACK FROM WELL # of feet = 100 SETBACK FROM POND, STREAM OR IRRIGATION DITCH # of feet = 50 SETBACK FROM DRY GULCH # of feet = 25 G Hepworth-Pawlak Geotechnical, Inc. 5020 County Road 154 ���/��/�.h Glenwood Springs, Colorado 81601 G4�Phone: 970-945-7988 HEPWORTH-PAWLAK GEOTECHNICAL Fax: 970-945-8454 email: hpgeo@hpgeotech.com April 23, 2004 Timberline Engineering Attn: Dave Powell P.O. Box 631 Carbondale, Colorado 81623 Job No. 104 308 Subject: Percolation Testing, Proposed Septic Disposal Systems, Flying Dog Ranch, 3045 Woody Creek Road, Pitkin County, Colorado. Dear Mr. Powell: As requested, Hepworth - Pawlak Geotechnical, Inc., performed percolation testing at the subject site. The testing was done in accordance with our agreement for professional services to Timberline Engineering, dated April 15, 2004. 10 Two profile pits and seven percolation test holes were excavated prior to our arrival on- site at the locations shown on Figure 1. The subsoils exposed in the profile pits consisted of about '/2 foot of topsoil and 1 to 1'h feet of slightly sandy to sandy clay and silt overlying silty sandy gravel with cobbles and boulders to the pit depths of 9% and 10 feet. No free water was observed in the pits and the soils were slightly moist to moist. Percolation test holes were hand dug in the bottom of the shallow backhoe pits and soaked with water on April 19, 2004. Percolation testing was conducted on April 20, 2004, by a representative of Hepworth - Pawlak Geotechnical, Inc. The percolation test results are summarized on Table 1. Area A showed infiltration rates between 8 and 17 minutes per inch with an average of 12 minutes per inch. Area B showed infiltration rates between 8 and 10 minutes per inch with an average of 9 minutes per inch. Based on the subsurface conditions encountered and the percolation test results, the tested areas should be suitable for a Oconventional infiltration septic disposal system. Pitkin County requires that a professional engineer design the septic disposal system. Parker 303-841-7119 9 Colorado Springs 719-633-5562 • Silverthorn.e 970-468-1989 U C Timberline Engineering April 23, 2004 Page 2 If you have any questions or need further assistance, please call our office. Sincerely, HEPWORTH - PAWLAK GEO Jordy Z. Adamson, Jr. Rev. by: SLP JZA/djb , INC. attachments Figure 1 - Location of Percolation Test Hole Table 1 - Percolation Test Results Job No. 104 308 GG' tech r m P1 NQ Q 2 0 ■ PROFILE PIT 6' AREA B co X 7750 P 1Q U\%Jf T A' AREA AREA A P Q Q>>40 P 4 ;?o 77 7800 0 —� 7- X770 7680 1104 308 HEPWORTH—P111AK LOCATION OF PERCOLATION TEST HOLES I Figure 1 GEOTECHNICAL, INC. Co X HEPWORTH-PAWLAK GEOTECHNICAL, INC. TABLE 1 PERCOLATION TEST RESULTS JOB NO. 104 308 Page 1 of 3 HOLE NO. HOLE DEPTH (INCHES) LENGTH OF INTERVAL (MIN) WATER DEPTH AT START OF INTERVAL (INCHES) WATER DEPTH AT END OF INTERVAL (INCHES) DROP IN WATER LEVEL (INCHES) AVERAGE PERCOLATION RATE (MINJINCH) P-1 (Area A) !I 48 10 131/4 11 21/4 17 11 91/2 11/2 91/2 81/2 1 81/2 71/2 1 71/2 61/2 1 61/2 6 1/2 6 51/4 3/4 51/4 4 3/4 1/2 P-2 (Area A) 53 10 Water added 9 61/2 21/2 i j 13 61/2 51/2 1 91/2 73/4 13/4 73/4 61/4 11/2 61/4 51/2 3/4 51/2 43/4 3/4 43/4 4 3/4 4 31/4 3/4 P-3 (Area A) 46 10 Water added Water added 123/4 63/4 6 9 141/2 73/8 71/8 141/4 73/4 61/2 73/4 51/4 21/2 51/4 33/4 11/2 33/4 3 3/4 3 1 3/4 1 1/4 Note: Percolation test holes were hand dug in the bottom of backhoe pits and soaked on April 19, 2004. Percolation tests were conducted on April 20, 2004. The average percolation rates were based on the last three readings of each test. Et L JICAL, INC. LTS )OB NO. 104 308 Page 2 of 3 HOLE NO. HOLE DEPTH (INCHES) LENGTH OF INTERVAL (MIN) WATER DEPTH AT START OF INTERVAL (INCHES) WATER DEPTH AT END OF INTERVAL (INCHES) DROP IN WATER LEVEL (INCHES) AVERAGE PERCOLATION RATE (MIN./INCH) P-4 (Area A) 57 10 Water added 11 1/4 8 3 1/4 8 8 53/4 2 1/4 12 9 1/2 2 1/2 9 1/2 71/2 2 7 1/2 5 1/2 2 5 1/2 4 1 1/2 4 23/4 1 1/4 23/4 13/4 1 Note: Percolation test holes were hand dug in the bottom of backhoe pits and soaked on April 19, 2004. Percolation tests were conducted on April 20, 2004. The average percolation rates were based on the last three readings of each test. Q HEPWORTH-PAWLAK GEOTECHNICAL, INC. TABLE 1 PERCOLATION TEST RESULTS JOB NO. 104 308 Page 3of3 HOLE N0. HOLE DEPTH (INCHES) LENGTH OF INTERVAL (MIN) WATER DEPTH AT START OF INTERVAL (INCHES) WATER DEPTH AT END OF INTERVAL (INCHES) DROP IN WATER LEVEL (INCHES) AVERAGE PERCOLATION RATE (MIN./INCH) P-1 (Area B) 44 10 Water added 133/4 93/4 4 8 93/4 7 1/2 21/4 14 11 3 11 8 1/2 21/2 8 1/2 6 1/2 2 6 1/2 5 1 1/2 5 3 3/4 1 1/4 33/4 21/2 1 1/4 P-2 (Area B) 44 10 Water added 13 1/4 10 1/2 23/4 8 10 1/2 8 1/4 2 1/4 13 1/4 11 1/2 1 3/4 11 1/2 9 1/4 2 1/4 9 1/4 7 21/4 7 5 1/4 13/4 5 1/4 33/4 1 1/2 3 3/4 3 3/4 P-3 (Area B) 64 10 Water added 10 83/4 1 1/4 10 83/4 73/4 1 73/4 7 3/4 10 1/2 9 1/2 1 9 1/2 8 1/2 1 8 1/2 7 1/2 1 7 1/2 6 1/2 1 6 1/2 5 1/2 1 Note: Percolation test holes were hand dug in the bottom of backhoe pits and soaked on April 19, 2004. Percolation tests were conducted on April 20, 2004. The average percolation rates were based on the last three readings of each test. a Q /•� 0 _ Historic Cabin / Bunk House 1, ' gCt V1�I,- Y"'1/'1/" fm AAI/"L.j ♦t\//'1/1P1�/ /�rJ 'L�G'V /x/91 /%in A PNI" gg 3i °� e CRAIG RANCH EXISTING WELL �� 8030 �o�o /o��j�/i \PR PER Y LINE — ,. ' 795 ,-- c, 104 IN�L �RIEA- 'EXISTING iEAdH FIEL ��� V ° J o 1 / l / I . fl ILII 11111 UI LD�NG EN�LOPE � � %/� r 1 � \ �II O �% � � I „ A V A 1 /�% � S , /, <: / '� \ �% ✓� �� \ \ ' il/�,� i r �r� "k, //�� �� rW7/` ti C l �, �i/� � �o � �� "V0 z, I �111 l l I I / i��/"//f / /i 0111 (fll�l��� / I �� I l 1 1 \ 7900/�j/� /,,,,`: ro9 I 1 /� ��//�'�/� i' EXfS IN ILIO E/ � / 11 111111 I I I v 7 /i, / �� o� 8,90/O� / / 01-19<1 v — — !/��rrrr�// // BED \ �9 A �i I 111 1 --- —=, o�� o� 111 \ 11 A 1 V 1 \ �_�� �,/j/ o� `11vI ,�%����'If�i16, doa F� i/� v= 099�� �rrir � OLgL \�\V A r 1/ i��// \, ,�. A'N �oe L \ �' o� G R H \ � - � � 111 \\1 \V � � \ v -�. � iii/ // � o vy ( 1II illi (�� A �I C Ili I _ — '// /Ao NEVI LEACH FIELD FO v _ A ( L�! � STRA WB -ALE HOUSE oz %�,� // �l1 / �i� II \�I , vvv ��� 11I �1 \ _ v / /i/i r �- � ��iiiiri EXISTING SPRING" \\ =06LL _ °ogL �� I� �' \\ �\ �� ��V III IIIA �"' v \1� \ v v / A ° / I ��� / y it p_ vI ��%ii �// sir � // o �% %i /1// o n o I a.❑ \ \ / / or I 'ir' / / S ALE 140 SE � % \ \ \ o v % I �� / �� �/ / I TIN v �/ //i/ l�1 �� o° i„����/i BED ESS G ° ,o/%! vti 50 I I X11 ���/ //IlI i� i/i BED PROPOSED l \ \ o 1 � 7g�0 r— \ yo off, \ C 'v / /// 1 /ii �I I I / v A vvv �. / / / .f /� /, y// o / /% �111 avi A \\�� 1 \ \ �(+Q V�f x��(��I VA\� \V A S� moo O �� \ \\�V A\ '����III VAS ��/%�� A\1 Q �A111 11 ��� I 2 �f / 9 INF UENC AREA \ ° \ \ �,,,� 100 I \ \ \ o °es / 00 0008 X \\\ \� o o I I If�llllflo og\` � �� \ \ �� � � � I �—� --' ° °� V' \ \. \\ \ �� ` ^ \ 202INFLUENCE AREA �\\°�� ������ � \� � ��A\� �AA\r�A � \ \ � % � �,i � � w ?�> 680 \ A w o \ \ \ \\ �1 • �\\\ � � = `� V \ I � IIII�II��IIII �1 0ON R,� 9,� oma\ \ \v\\�����\ w� 6 2 '39 \\\ A\\�\ V�V oggz 7T, \`°� �\ \ ��Ajll�l� IIS V� ��\ <9<'❑ 0,6 00 TWO MIL w�vvvv � � ,°��AMSA yr<`' � k � Co \\A� t 7111F, \ N 07�7�° \�Q \\\ \ \ \ \ ru `-- Lit 0 CL r >o \ \ I� )OD Y CREEK ROAD w o �u -11 M, S 90000'00"W 1270,79' GRAPHIC SCALE 200 0 100 200 400 ( IN FEET ) 1 inch = 200 ft. 'Y 201 RECEIVED JUL 0 7 2004 PITKIN COUNTY EWIRONMENTAL HEALTH . a •.d f k .. i.9 x COPYRIGHT DRAWN BY DA 0 Z00 M N 00o O W � � OM U O z W Z, Orn pa'a O� M U `o C*� l O M � Z. W � O H DRAWN BY DA DATE 07/01/04 REVISIONS xx SCALE AS SHOWN DRAWING AREA of SEPTIC INFLUENCE SHEET U � Z Z. DATE 07/01/04 REVISIONS xx SCALE AS SHOWN DRAWING AREA of SEPTIC INFLUENCE SHEET