HomeMy WebLinkAboutpitkin.eh.264323300002 (2010)ONSITE WASTEWATER TREA .JIENT SYSTEM (OWTS) CONSTRUCTION PERMIT 0405 Castle Creek Road, Suite 10 - Aspen, CO - 81611 Phone: 970.920.5070 Fax: 970.920.5077 Permit #: 0044.2010.powt Parcel ID #: 2643-233-00-002 Permit Issued: ❑NEW QREPAIR ®REMODEL/ADDITION ❑TANK ONLY ❑FIELD ONLY []AMENDMENT Owner(s): GRE II, LLP Property Address: 1025 Star Mesa Drive Legal Description: Westcliffe Parcel, Lots 19 & 20, Star Mesa Size of Lot: 37 Acres Detached Accessory Unit: Size of Building: 14,214 Sq. Ft. Size of Accessory Unit: The system is designed for: 11 bedrooms (current plans indicate powder room) n Designed By: Phone #: _ Fax #: All Service Septic 97C-618-5033 303-216-2796 Perc Rate: 17 mpi Minimum Tank Capacity []YES ®NO Sq. Ft. ;bedrooms plus a future pool area with a t r CVanCc orgy Mans Co 2118 Project #: 1739 Dated: Mailing Address: PO Box 2844, Glenwood Springs, CO 81602 Email Address: Tpetz1(a)comcast.net Profile Hole Depth 4125 aallons 8 ft Depth to Groundwater or Bedrock: Greater than 8 ft Minimum Absorption Area: 1905 sq ft w/ 50% reduction Permit Conditions: This OWTS Construction Permit is approved on the condition of compliance with the engineer design as submitted with the application and the specifications cited above. Changes must be approved by this Department and the engineer prior to construction. The existing system will be abandoned and replaced. The new system will consist of one 2500 gallon single compartment tank followed by a 2000 gallon, two-compartment tank with an effluent filter on the outlet and a 500 gallon tank with a dosing siphon. A flow splitter basin will distribute effluent to 5 trenches. The first 4 trenches will consist of 21 Quick 4 chambers tied serially into another 17 chambers and the last trench will be a row of 23 chambers tied serially into another 23 chambers. Each trench set should be separated by 6 feet of undisturbed soil. The trenches should have approximately 1 '/2 to 2 '/2 feet of cover over the chambers. This Permit must be kept on-site during installation. The engineer must do a final inspection of the installation and submit an "as -built" letter to this Department within 30 days of the final inspection, unless a longer period of time has been agreed upon, in writing. This Department must also be called for the final inspection with a minimum of 48 hours notice. Minimum horizontal distances between components of the system and physical features shall conform to the requirements of the Pitkin County OWTS Regulation. This Permit is conditioned upon the property owner(s) providing for regular inspection, cleaning, and maintenance of the system by qualified personnel, in accordance with the manufacturer's recommendations and the requirements of the Pitkin County OWTS Regulation. Issuance of this OWTS Construction Permit does not constitute a guarantee, warranty, or representation by the Department that the system will operate properly or will not fail. THIS PERMIT IS EXPRESSLY CONDITIONED UPON COMPLIANCE WITH ALL REQUIREMENTS OF THE PITKIN COUNTY OWTS REGULATION, INCLUDING BUT NOT LIMITED TO THOSE CONDITIONS SPECIFIED ABOVE. Plans and specifications for the proposed OWTS have been reviewed and are considered satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated in accordance with the Pitkin County OWTS Regulation. This Permit will expire 1 year frorn the date of issuance unless construction on the system has commenced. An "as -built" drawing must be submitted and approved by EH/NR before final approval of the system will be issued. r, Issued By: (�g� t- �� Date: �/ L / l I Expires: / / & / /- Installer:icense #: ^� )fl � Reactivation Authorized by: n (11 Final Appr al Issued By: Dat 3 k�=, Id Li New Expiration D S�wl k:!-- 0 au -0 cn/Nl�/1 im ONSITE WASTEWATER TREATM� ..T SYSTEM (OWTS) CONSTRUCTION PERMIT APPLICATION 0405 Castle Creek Road, Suite 10 - Aspen, CO • 81611 IPhone: 970.920.5070 Fax: 970.920.5077 Parcel ID# (available from the Pitkin County Assessor's Office t � Z33 d� Z 970-920-5160 or at www.pitkinassessor.org): 6 4 Purpose of Permit: J NEW ❑ REPAIR DUE TO FAILURE REMODEL/ADDITION ❑ TANK ONLY ❑ FIELD ONLY Cost of System Repair or Remodel/Addition (approximate): Property Address: i Z.) Z 5_ srh1Z »ash n 121v� �lsn�,�, �L ►� v Lot: Block: Filing: Subdivision: LvF-:5T4 PItQCEL LOTS l�It2 _ SjffZT14VN 23 715Xelrw 'roperty Owner(s)': Email Address: vw1r) 6EA_SrEi-1H ►13aEz ( (p?c- IL CIP0 )wner's Mailing Address: City, State, Zip: s46 fir-TH AVF_ 17TH FLaOM N%/ NY 1,04)36 lome Phone: Business Phone: 21 Z- 7 s z •- !!:S-4-1 i 1 Z- IS* z, - S-5-49 Contact information must be orovided for the owner sionino this aoolication. Primary Contact Person/Applicant (if not owner): Company: Contact/Applicant Mailing Address: City, State, Zip: 11) 5. M011V24N Asper -1 L-- 0 41111 Cell Phone: Business Phone: Fax Number: 0T v - X44 - 14% 3 Email Address: L �.t• r r .. y+d �... c uilding Permit # (if applicable): ooS'S. 24!P110. Pa5k of Size (in acres): 37.410 Ac. + ize of Building (square feet): Number of Potential Bedrooms: 14, 214 10 ietached Accessory Unit? F] YES ANO Size of Accessory Unit (square feet): umber of Potential Bedrooms In or Fixture List for the Accessory Unit: Jater Source: 1,XPRIVATE WELL ❑ SURFACE WATER ❑ SPRING ❑ COMMUNITY/PUBLIC WATER SYSTEM ame of Community/Public Water System (if applicable): ngineering Firm: Job Number: Phone Number: Fax Number: ALL SEaV1LE ::sEPnz_ 17347 970.614'• So33 34)4•2.1Z -7 --MZ failing Address: City, State, Zip: P.o. f3vX 2844 G4&P41VV ,7 SPRAWk 5 4-OL-01LAD4 1160 Z .,-ASE READ BEFORE SIGNING' I certify that the above information is complete and accurate and that 1 have provided complete and accurate information in all of the documents included in my application package. I acknowledge that EH/NR may revoke any permit I am issued if my application is found to contain any inaccurate, false, or misleading information. I understand that no construction may be undertaken on an OWTS until an OWTS Construction Permit is issued. Owner Signature (Required): Date: zt12-� -gyp Applicant Signature: Date: q F OFFICE USE wY Received by EN/HR St Fee &Receipt #: Date: ��3 Updated 10/7/08 PITKIN (,AUNTY COMMUNITY DEVELU -'MENT Permit Receipt RECEIPT NUMBER 00030225 Name: Roland and Broughton Date: 12/14/2010 Project Address: 1025 STAR MESA DR Type: check # 24655 Permit Number Fee Description Amount 0044.2010.POWT OWTS Fee 0044.2010.POWT OWTS Fee-StateShare Total: 1,003.00 20.00 1,023.00 Pitkin County Environmental Health Department Contact Log Sheet • D. •.. - s®- '. .. . _ �® a 0 L PO Box 2844 ' Glenwool1, inp,C081102 SEBV�C�Ph 970-618.5033 'IMF W303-216-27% June 20, 2012 Project No. 1739 Roland and Broughton 117 South Monarch Street Aspen, CO 81611 Installation Observations Westcliffe Project 1025 Star Mesa Drive Pitkin County, Colorado Richard, ALL SERVICE septic, LLC performed installation observations for the onsite wastewater treatment system (OWTS) on May 4th, July 19th, August 9th, and October 18th 2011 for the subject property. On May 4th a site visit was conducted to evaluate the existing drain fields and implications of the existing liners. A letter was provided. On July 191h we observed the septic tanks, and requested a filter handle. We requested the primary outlet tee be raised, and a change in the 90 deg fitting in the Flow Splitter Basin. On August 91h we observed prior requests completed. The installation included a 2500 gallon single compartment septic tank, followed by a 2000 gallon single compartment septic tank with an effluent filter, followed by a 500 gallon septic tank with a dosing siphon. The drain field consisted of 10 gravelless chamber trenches with a total of 198 Q-4 chambers, equaling an area of 1955 SF. A flow splitter basin serves effluent to the drain field. The OWTS was generally installed according to specifications. This observation is not a guarantee of workmanship and/or parts and materials. ALL SERVICE septic, LLC should be notified if changes are made to the OWTS. LIMITS: The observation was based on information submitted and our site visit. If conditions are different from conditions described in this letter, ALL SERVICE septic, LLC should be notified. All additional OWTS construction must be according to the county regulations. The installer should have documented and demonstrated knowledge of the requirements and regulations of the county in which they are working. ALL SERVICE septic, LLC Timothy R. Petz Copy sent to Pitkin County Health Dept. Reviewed Richard B X WESTCLIFF 1025 STAR MESP DRIVE SEPTIC RECORD 1" = 20'-0" Pb Box 2844 dlenwood Springs, CO 81602 311 CE Ph 970.618-5033 L Fax 303-216-2796 May 5, 2011 Richard, During our site visit on May 5th 2011 we observed the digging of one test hole on the outskirts of the existing drain field. The west `lined' drain field was full of water. I understand it is the owners preference to move the proposed drain field trenches to the west and not interact with the existing drain fields. If there is no interaction with the existing drain fields, and the proposed trenches are not within 20 feet of existing lined ETA beds, the ETA beds do not have to be altered. They can remain in place and be `abandoned' Tim Petz OWTS DESIGN CALCULATIONS - for Pitkin Owner's Name ,()`1.. Parcel ID # x.4 f, A" House Size (sq. ft.) , ° ' (75 gpd or 100 gpd) 100 Number of Bedrooms in Main House Number of Offices, Libraries, Studies, Similar -sized Rooms in Main House Number of Bedrooms in Detached Caretaker unit Number of Offices, Studies, Similar -sized Rooms in Caretaker Unit (If the caretaker unit is ATTACHED, treat as if part of main house.) Average Daily Waste Flow 2200 State Review Required? no Perc Raters r (I ) Design Flow (Q) _ # potential bedrooms X 2 people/bedroom X gpd X 1.5 Q= 3300 250o -j 2oaC) - q.6004,500:": Minimum tank capacity 4125 gallonsA Absorption Area (=Q/5 X SQRT perc rate)(1.4 loading factor) A = 3,810 sq. ft. of absorption area required 1 Absorption Area (=Q/5 X SQRT perc rate) WITH SECONDARY TREATMENT (no loading factor) A= 2,721 sq. ft. of absorption area required Abs. Area w/ loading factor (B25) Trench Pipe and Gravel (-10%) 3429 Dosing (-20%) 3048 Chambers (-30%) 2667 Max Allowable (50%) 1905 Secondary Treatment (-30%) 2667 Abs Area w/ out loading factor (B28) 270 Trench Pipe and Gravel (-10%) 2449 Dosing (-20%) 2177 Chambers (-30%) 1905 Max Allowable (-50%) 1361 284 SETBACK FROM WELL # of feet = 234 SETBACK FROM POND, STREAM OR IRRIGATION DITCH # of feet = 209 SETBACK FROM DRY GULCH # of feet = Bed Quick4 Trench Quick4 Bed no red. 3810 347 386 (-20%) 3048 309 309 (-10%) 3429 270 347 (-30%) 2667 193 ' 270 Bed 199 no red. 2721 248 276 (-20%) 2177 221 221 (-10%) 2449 193 248 (30%) 1905 138 193 Q$� 0 k -e lX25 LSA. S(.X_ ;'E Z I°J Carla Ostberg From: Tim Petz [tpetz1@comcast.net] Sent: - Wednesday, November 09, 2011 7:03 AM To: Greg Wesley Cc: Carla Ostberg Subject: Re: Septic tank inlet pipe Greg, Please Drill a 3/16 -inch hole on the bottom side of the elbow in the Flow Splitter Basin per my request, and our discussion. This will complete our septic construction and I will write letters to county for final approval. CARLA - The elbow in the flow splitter basin has no room to turn or twist... therefore I am requesting weep hole in elbow. This will allow for energy reducer device, and prevent freezing due to draining. Tim Petz All Service septic, LLC / ITS, Inc PO Box 2844, Glenwood Springs, CO 81602 970-618-5033 6147 Braun Court, Arvada; CO 80004 303-908-7823 FAX 303-216-2796 From: "Greg Wesley" <greg(@johnolsonbuilder.com> To: "Tim Petz" <t etz1 cD_comcast.net> Sent: Tuesday, November 8, 2011 1:30:38 PM Subject: Septic tank inlet pipe Tim, Just a reminder we agreed upon drilling a 3/16 hole in the elbow of the inlet pipe where it turns up, the distance from the bottom of the pipe tolthe floor of the tank is only 1", this will serve as a drain for the pipe. Thank you for your help on this and am looking forward to your e-mail blessing this procedure. Thanks Greg Wesley Superintendent/Project Manager John Olson Builder, Inc. 200 East Main Street Aspen, CO 81611 970.923.4233 office 970.923.2977 fax 970.319.5544 mobile www.iohnolsonbuilder.com �u�tocP �c 10, NOTICE The contents of this e-mail including any attachments may contain confidential or privileged information and are to be read solely by the intended recipient(s). If you are not the intended recipient, you are hereby notified that any dissemination, distribution or copying of this e-mail and any attachment(s) is strictly prohibited. If you have received this e-mail in error, please immediately notify the sender by replying to this e-mail and delete the message and any attachment(s) from your system. Thank you. Email secured by Check Point e-mail in error, please immediately nOL,ry the sender by replying to this e-mail and aelete the message and any attachment(s) from your system. Thank you. Email secured by Check Point Carla Ostberg From: Carla Ostberg Sent: Monday, August 22, 2011 12:26 PM To: 'Greg Wesley' Cc: 'Tim Petz' Subject: RE: Westcliffe Project G reg, Yes, I am happy. I have a couple of notes from the inspection that I did with Tim. One was that the pipe coming into the flow splitter basin angles up. Tim and I thought that could cause a freezing issue and it would be better to angle it down. Tim was going to Check on the final grading. Also, we'll need confirmation that the dosing siphon is hooked up and primed prior to CO. It might be too early to think about doing that yet, but once you are getting ready to put the system on line you can finish the installation and I will finalize the paperwork. Thanks, Carla Ostberg, MPH, REHS Environmental Health Manager Pitkin County Environmental Health 970-920-5438 .-4— From: Greg Wesley mailto:greg(ajohnolsonbuilder.coml Sent: Monday, August 22, 20118:34 AM To: Carla Ostberg Subject: Westcliffe Project Hi Carla, I was just going through things on the site and we are all caught up but thought that I would drop you a line and see if there was anything that you might want to, or need to come and take a look at. The project is going well Tim is happy and the rest of the engineers seem to be happy so just wanted to make sure that you are happy too. Please feel free to call or e-mail at any time. Thank You Greg Wesley Superintendent/Project Manager John Olson Builder, Inc. 200 East Main Street Aspen, CO 81611 970.923.4233 office 970.923.2977 fax 970.319.5544 mobile www.iohnolsonbuilder.com JOHN OMINIZENV'sON NOTICE The contents of this e-mail including any attachments may contain confidential or privileged information and are to be read solely by the intended recipient(s). If you are not the intended recipient, you are hereby notified that any dissemination, distribution or copying of this e-mail and any attachment(s) is strictly prohibited. If you have received this Carla Ostber From: Tim Petz [tpetz1@comcast.net] Sent: Thursday, February 24, 2011 1:35 PM To: Carla Ostberg Cc: Richard Kihnley; Larry Subject: Re: 1025 Star Mesa or Legal Description West cliffe Parcel Star Mesa Land in lots 19 & 22 of SEC 23-9-85 DESC by BK 630 PG 921 BK 635 PG 771 Oh Carla, now I get your question ....... sorry ..... Please have the excavator 'rip' the existing liner 20 feet on all sides of the new drain field. Just dig down and tear liner in multiple spots (every 12 feet or so) to prevent a bathtub effect.. good points, thanks. Larry call me if you need additional info. Tim Petz All Service septic, LLC / ITS, Inc PO Box 2844, Glenwood Springs, CO 81602 970-618-5033 6147 Braun Court, Arvada, CO 80004 303-908-7823 FAX 303-216-2796 ----- Original Message ----- From: "Tim Petz" <tpetz 1 @com cast. net> To: "Carla Ostberg" <Carla.Ostberg@co.pitkin.co.us> Cc: "Richard Kihnley"<rkihnley@johnolsonbuilder.com>, "Larry" <viIlageexc@comcast. net> Sent: Thursday, February 24, 2011 1:29:22 PM Subject: Re: 1025 Star Mesa or Legal Description Westcliffe Parcel Star Mesa Land in lots 19 & 22 of SEC 23-9-85 DESC by BK 630 PG 921 BK 635 PG 771 The existing drain field is an ETA bed with a liner. Therefore we really need to remove the liner under the areas of the new drain field only. I have seen the liners pulled up before and they come out relatively easily. I am less concerned with the gravel and or sand that is in the field being removed, that would not hinder the proposed new system. Just the liner and fabric should be pulled out, under the new field area only Tim Petz All Service septic, LLC / ITS, Inc PO Box 2844, Glenwood Springs, CO 81602 970-618-5033 6147 Braun Court, Arvada, CO 80004 303-908-7823 FAX 303-216-2796 W 0 ----- Original Message ----- From: "Carla Ostberg" <Carla.Ostberg@co.pitkin.co.us> To: "Larry" <viIlageexc@comcast. net>, "Tim Petz" <tpetz 1 @com cast. net> Cc: "Richard Kihnley" <rkihnley@johnolsonbuilder.com> Sent: Thursday, February 24, 2011 12:57:19 PM Subject: RE: 1025 Star Mesa or Legal Description Westcliffe Parcel Star Mesa Land in lots 19 & 22 of SEC 23-9-85 DESC by BK 630 PG 921 BK 635 PG 771 Larry, Yes, if the soils appear to be saturated, I would say the Tim will need to come in and make a determination if soil replacement needs to occur. I know that puts a variable in your bidding process, which is never ideal. Hard to say what we'll see until you get in there. Tim, can you comment on the remaining field area liner? Should we try to perforate that as part of the abandonment process? I hate to see that liner intact still creating the bathtub effect and relying solely on evaporation. Carla Ostberg, MPH, REHS Environmental Health Manager Pitkin County Environmental Health 970-920-5438 From: Larry [mailto:villageexc@comcast.net] Sent: Thursday, February 24, 2011 9:01 AM To: 'Tim Petz' Cc: 'Richard Kihnley'; Carla Ostberg Subject: RE: 1025 Star Mesa or Legal Description Westcliffe Parcel Star Mesa Land in lots 19 & 22 of SEC 23-9-85 DESC by BK 630 PG 921 BK 635 PG 771 Ok Tim.. I'll just make a note in my proposal to John Olson Builders regarding the removal and import of clean granular soils if required. Just to be clear on that judgment call, who will determine if there is a need to remove and replace? You I presume? Thanks, Larry Custodio Village Excavating, Inc. 970-948-5079 Cell 970-704-0505 Office 970-704-0609 Fax villageexc(o),comcast. net From: Tim Petz [mailto:tpetzl@comcast.net] Sent: Thursday, February 24, 20118:37 AM To: Larry Cc: Richard Kihnley; Carla Ostberg Subject: Re: 1025 Star Mesa or Legal Description Westcliffe Parcel Star Mesa Land in lots 19 & 22 of SEC 23-9-85 DESC by BK 630 PG 921 BK 635 PG 771 If I could comment i would say, no need to bring in any soil UNLESS the soil is totally saturated and full of Biomat. then yes, bring in granular material, and place in 1 foot lifts, then bucket pack for compaction. t I dont believe the soils will be 'yucky' ...we will see. Tim Petz All Service septic, LLC / ITS, Inc PO Box 2844, Glenwood Springs, CO 81602 970-618-5033 6147 Braun Court, Arvada, CO 80004 303-908-7823 FAX 303-216-2796 at all, and should be fine for construction of drain field. BUT ----- Original MessagE) ----- From: "Larry" <villageexc@comcast.net> To: "Carla Ostberg"<Carla.Ostberg@co.pitkin.co.us>, "Tim Cc: "Richard Kihnley" <rkihnley@johnolsonbuilder.com> Sent: Wednesday, February 23, 2011 5:07:21 PM Subject: RE: 1025 Star Mesa or Legal Description Westcliffe SEC 23-9-85 DESC by BK 630 PG 921 BK 635 PG 771 Petz" <tpetz1 @comcast.net> Parcel Star Mesa Land in lots 19 & 22 of Carla, In the areas of overlap what would be the preferred method off soils removal / replacement. Do you what us to remove X' - X" amount of soil and replace with non -contaminated native soil excavator bucket compacted than scarified? Let me know your thoughts. Thanks, Larry Custodio Village Excavating, Inc. 970-948-5079 Cell 970-704-0505 Office 970-704-0609 Fax villageexc(d-)comcast. net From: Carla Ostberg[maiIto:Carla.Ostberg@co.pitkin.co.us] Sent: Wednesday, February 23, 20114:39 PM To: Larry; Tim Petz Cc: Richard Kihnley Subject: RE: 1025 Star Mesa or Legal Description Westcliffe Parcel Star Mesa Land in lots 19 & 22 of SEC 23-9-85 DESC by BK 630 PG 921 BK 635) PG 771 Larry, That's a really good question that I don't think was adequately addressed either in the design or the permit. But I did think about it! The existing field is a lined (10 mil PVC) ET bed with pipe and gravel covered with a mirifi fabric (or 4" straw over the distribution piping). It might be feasible to perforate the liner rather than digging it up. It looks like the system is 2-6" of topsoil, 7" of sand, fabric, 13" of rock, and the liner under that, so about 2' deep. Of course any portion of the new field that overlaps the old will need to be entirely removed, but I don't know if there would be any harm in leaving the rest of the system in place and providing a mechanism for water to get through it. We don't want additional water to be diverted toward the new system. Tim, what do you think??? Carla Ostberg, MPH, REHS Environmental Health Manager Pitkin County Environmental Health 970-920-5438 to 0 From: Larry [mailto:villageexc@comcast.net] Sent: Wednesday, February 23, 20113:52 PM To: Carla Ostberg; Tim Petz Cc: 'Richard Kihnley' Subject: 1025 Star Mesa or Legal Description Westcliffe Parcel Star Mesa Land in lots 19 & 22 of SEC 23-9-85 DESC by BK 630 PG 921 BK 635 PG 771 Carla & Tim, 1025 Star Mesa septic plans call for "Existing Drain Field to be removed" liner under proposed trenches must be removed. Please clarify the extent of removal of "Existing Drain Field" Are we talking removal all chambers, piping and liner as well as the soils underneath the existing trenches or do you have something else in mind? I've attached Tim's plans for your review. Let me know your thoughts. Thanks, Larry Custodio Village Excavating, Inc. 970-948-5079 Cell 970-704-0505 Office 970-704-0609 Fax vil lageexc(o)comcast. net No virus found in this message. Checked by AVG - www.avg_com Version: 10.0.1204 / Virus Database: 1435/3463 - Release Date: 02/23/11 No virus found in this message. Checked by AVG - www.aviz.com Version: 10.0. 1204 / Virus Database: 1435/3464 - Release Date: 02/23/11 Email secured by Check Point Email secured by Check Point Carla Ostberg From: Michael Kraemer Sent: Monday, November 15, 2010 12:00 PM To: 'Ryan Hoffner' Cc: John Rowland; Sarah M. Broughton, Nick Ketpura; Carla Ostberg Subject: RE: WESTCLIFFE - (1025 Star Mesa remodel) That is correct. I've cc'ed Carla on this email. Thanks, Mike From: Ryan Hoffner[mailto:ryan@rowlandbroughton.com] Sent: Friday, November 12, 2010 4:06 PM To: Michael Kraemer Cc: John Rowland; Sarah M. Broughton; Nick Ketpura Subject: WESTCLIFFE - (1025 Star Mesa remodel) Mike, Thank you for taking the time to meet with us on site to review the scope and extent of the septic field. As discussed we will be allowed to pull our building permit for the work proposed inside the approved building envelope with the condition that the owners will have their amended Land Use Approvals in place before the C of O is issued. We will submit a OWTS waiver at the time of our permit submittal and I will talk to Carla at Environmental Health to see how to proceed with her review. Thanks again and have a great weekend! Ryan P. Hoff ner, AIA rowland+broughton architecture and urban design 117 s. monarch street aspen, co 81611 970.544.9006 v 970.544.3473 f www.rowlandbroughton.com 2010 AIA Colorado West Award of Citation Winner Economy of Means Otto's House Woody Creek, Colorado Email secured by Check Point flflneEiiptic PO Box 2844 Glenwood Springs, CO 81602 Ph 970-618-5033 Fax 303-216-2796 December 291h 2010 Roland and Brou.0ton Attn: Ryan 117 South Monar�h Street Aspen, CO 81611 Project No. 1739 Subsurface Investigation and Revised Upgrade Wastewater Treatment System Design Westcliffe Project 1325 Star Mesa Drive Pitkin County, Colorado Ryan, ALL SERVICE septic, LLC performed a subsurface investigation and an onsite wastewater treatment system (OWTS) design for the subject residence. The property is located outside of Aspen, in an area where OWTS and wells are necessary. The revision is based on a tank and drain field sizing clarification. SITE CONDITIONS A single-family residence presently exists and is utilizing an OWTS, The current drain field will have to be abandoned, and the liners partially removed due to existing trees. An 11 -bedroom residence having over 6000 SF is planned. Remodeling will take place. The proposed drain field area slopes 8% to the west, and vegetation consists of a moderate cover of grasses with sparse trees. The property is served by a well located 300+ feet to the southwest of the residence. SUBSURFACE The subsurface was investigated by drilling one profile hole and 3 percolation holes, as indicated. The materials encountered in the profile hole consisted of 1.5 feet of sandy clay topsoil, underlain by sandy clay with scattered rocks to the maximum depth explored of 8 feet. Groundwater or bedrock was not encountered. Three percolation holes were dug, in the area of the proposed drain field, as indicated. Percolation rates ranged from 10 to 20 minutes per inch (MPI). A 17 MPI rate will be used to design the OWTS. ® Onsite Wastewater Systems Page 2 DESIGN SPECIFICATIONS The OWTS design is based on 11 -bedrooms and an average sewage load of 2200 GPD. The installation must include a 2500 -gallon, single -compartment, precast concrete septic tank, to be followed by a 2000 -gallon, single compartment concrete septic tank with an effluent filter, followed by a 500 gallon septic tank with a dosing siphon. (Front Range Precast out of Boulder 303-442-3207 can supply large tank). Tank alternatives may be considered. Ten gravelless chamber trenches, using " `Quick -4' InfiltratorTM chambers, must be installed as indicated. There must be a total of 198 chambers and 1955 SF of infiltrative area. A flow splitter basin must be installed to distribute effluent. Construction must be according to the Pitkin County Environmental Health and Natural Resources Department OWTS regulations, the OWTS Construction Permit provided by Pitkin County Environmental Health and Natural Resources Department, and this design. OPERATION INFORMATION AND MAINTENANCE The surface of the drain field should be seeded upon completion. Vegetation is an important factor in drain field performance. Erosion control should be practiced prior to and during re -vegetation. Geo - fabrics or plastics should not be used over the drain field. No heavy equipment, machinery, or materials should be placed on backfilled drain field. Livestock should not graze on the drain field. Plumbing fixtures should be checked to ensure that no additional water is being discharged to OWTS. For Example, a running toilet or leaky faucet can discharge hundreds of gallons of water a day and harm a drain field. The homeowner should pump the septic tank every two years and clean the effluent filter as needed. Garbage disposal use should be minimized, and non -biodegradable materials should not be placed into the OWTS. Grease should not be placed in household drains. Loading from a water softener should not be discharged into the OWTS. No hazardous wastes should be directed into the OWTS. Mechanical room drains should not discharge into the OWS. The OWTS is engineered for domestic waste only. ADDITIONAL CONSTRUCTION NOTES If design includes a pump, air release valves and weep holes should be installed to allow pump lines to drain to minimize risk of freezing. Excavation equipment must not drive in excavation of drain field due to the potential to compact soil. Extensions should be placed on all septic tank components to allow access to them from existing grade. Precast concrete tanks and distribution boxes should be used, unless plastic or fiberglass is required. Access to all tank compartments and distribution devices is optimal. INSTALLATION OBSERVATIONS ALL SERVICE septic, LLC, and the county must view the OWTS during construction. The OWTS observation should be performed before backfill, after placement of chambers and distribution pipes. Septic tanks, distribution devices, pumps, dosing siphons, and other plumbing, as applicable, must also be observed. ALL SERVICE septic, LLC should be notified 48 hours in advance to observe the installation. L LIMITS: 1 Onsite Wastewater Systems Page 3 The design is based on information submitted. If soil conditions encountered are different from conditions described in report, ALL SERVICE septic, LLC should be notified. All OWS construction must be according to the county regulations. Requirements not specified in this report must follow county regulations. The installer should have documented and demonstrated knowledge of the requirements and regulations of the county in which they are working. Please call with questions. Sincerely, ALL SERVICE septic, LLC Timothy R. Petz 3 copies sent Reviewed a Richard H WJ PITKIN COUNTY ENVIRONMENTAL HEALTH DEPARTMENT Percolation Test and Soils Data Form - TABLE 1 - PROJECT 1739 Performed by All Service Septic, LLC PROFILE PIT uaie vi i u5i. i ci 1 cicuuu 0 - 1.5' Root Zone, Sandy Clay, Brown to Red 1.5'-8.0' Clay, Sandy, Silty, Stiff, Scattered Rocks (up to 1 ft diam) Moist Brown to Red nln rrni inHXA1ntar nr RPrlrnnk waS Encountered Hole No. Hole Depth (in.) Interval (min.) Measurement at Start of Interval (in.) Measurement at End of Interval (in.) Change (in.) Percolation Rate (min./in.) MPI 1 40 20 11.75 13.25 1.50 13.50 14.50 1.00 20 13.25 15.75 2.50 20 15.50 16.50 20 15.75 18.00 2.25 fill 20 12.00 15.25 3.25 20 15.25 18.00 2.75 20 18.00 20.00 1.00 10 2 38 20 12.25 14.00 1.75 20 14.00 14.75 0.75 20 14.75 15.75 1.00 20 15.75 16.75 1.00 fill 20 13.00 14.25 1.25 20 14.25 15.25 1.00 20 3 40 20 12.00 14.00 2.00 20 14.00 16.00 2.00 20 16.00 dry fill 20 13.50 14.50 1.00 20 14.50 15.50 1.00 20 15.50 16.50 1.00 20 AVG = 17 MPI V rowland + broughton architecture and urban design 117 s. maarch It. 3377 bloke st, 106 aspen.W 8 161 1 denver. co 80205 970.54.goo " 303..1173v 970.SM.3 131 303.308.1375 f Consulianls SEBYICE P.O. Box 2844 Glenwood Springs, CO 81602 Phone 970.618.5033 Fax 303.216.2796 ........ ........... I ........ .... I.. : 11.11.2010 DEMOLITION PERMIT WESTCLIFFE 1025 STAR MESA DRIVE ASPEN, CO 81611 ....................................................... PROJECT NO: 21020 DWG FILE: PROPOSEDOWS 12.2.2010 REV. 12.29.10 ENLARGED PROPOSED OWS L 1" = 20'-0' t0' 20' 30' 40• Scale: 1' = 20'- 0' rowland + broughton architecture and urban design 117 a. nnlm . 33771ake at, 106 .-P-1 m 8 aeV1611 damer, m W205 970. '9006 v 303.306.1373 v 970.544.34731 303.306.13751 Consultants septi SERVICE P.O. Box 2844 Glenwood Springs, CO 81602 Phone 970.618.5033 Fax 303.216.2796 .............. . .................. _..... 1—' 11.11.2010 DEMOLITION PERMIT WESTCLIFFE 1025 STAR MESA DRIVE ASPEN, CO 81611 PROJECT NO: 21020 DWG FILE: ENLARGED PROPOSED OWS 12.2.2010 REV. 12.29.10 SCALE: 1' = 20' - 0" ........................................................._._.........._....... DESIGN 11 -BEDROOM RESIDENCE - LOADING • q • 2200 GALLONS PER DAY PERCOLATION RATE • t • 17 MINUTES PER INCH (MPI) CALCULATED AREA • ((1.5 X q X sgrt I) 15 x 1.4) - 3810 SF PROPOSED AREA • 3810 SF TRENCH AND DOSING REDUCTION • 3810 SF X 50% REDUCTION = 1905 SF TRENCH SPECIFICATIONS WIDTH OF TRENCHES = 3 FEET =1 CHAMBERS LENGTH OF'OUICK-4' TRENCHES - VARIES. SEE DIAGRAM TOTAL NUMBER OF'DUICK4 CHAMBERS'' 198 TOTAL INFILTRATIVE AREA= 1954 SF TEN TOTAL TRENCHES SWEEP / 2 WAY CLEANOUT DETAILS (N.T.3) TYPICAL DRAIN FIELD CROSS SECTION -TYP. SUP -ON PVC CAP FINISHED GRADE 4" PVC OBERVATION PIPE W/ CAST IRON LIMIT OF COVER AT GRADE EXCAVATION Ir I EFFLUENT Concrete Riser and Ud to Surface 814 NRWAY AVENUE 3.5' MAX L sU1HERUN, N 6 MIN 2.5 MIN J 4" GRAVELLESS LINE -4' L CHAMBER SCARIFY SURFACE SCHEDULE 4' (41'. 3') PRIOR TO PLACEMENT OF SAND SWEEP / 2 WAY CLEANOUT DETAILS (N.T.3) TYPICAL - SUP -ON PVC CAP FINISHED GRADE 00 NOT GLUE OrenCo Systems® EFFLUENT Concrete Riser and Ud to Surface 814 NRWAY AVENUE LINE- INE-SEWER sU1HERUN, N SEWER 974]9-9012qa=('A 4" FAae� (%I) 159-2884 LINE -4' L SCHEDULE INSULATED SCHEDULE 4' (800) 348-9843 40 OR COPPER 40 P.V.C. TELEPHONE 4'SDR TRACERWIRE (541) 459-4H9 35 MAYBE 1 1 (55459-2884 P.V.C. INSTALLED TO LOCATE LINE IN FUTURE OBSERVATION INFILTRATOR(R) OUICK4(TMI CUT SHEET PIPE 52" 48" E T L N 12' 34" ZJA 16 2', PVC PIPE TO ENTER IN TOP PORT OF END PLATE i' PLAN VIEW - 1 TY. GRAVELLESS CHAMBER DUICK-4' 92 FEET PIPE TO ENTER 23 CHAMBERS PER TRENCH CHAMBER IN TOP PORT OF END PLATE SERIAL OVERFLOW PIPES 68 FEET 17 CHAMBERS PER TRENCH END PLATE OBSERVATION PIPE 6' MIN 17 CHAMBERS PER TRENCH I I 21 CHAMBERS PER TRENCH 88 FEET 84 FEET NOTE: ANGLE TRENCHES TO FOLLOW SITE CONTOURS n TRENCH DETAILS � NOT TO SCALE Typical Septic Tank - 2000 to 2500 -gallon, single compartment - Effluent filter on second Concrete Risers with Lids Orenao Systems® Incorporated 814 AIRWAY AVENUE SIOpe Ground MHER011, OREGON Away From Risers 97479-9012 WrT RIEPHONE: (541) 459-4449 FAr.SINILE: Inlet Tee (541) 459-28& Flow Splitter Balm t Oisoharge )ND TANK ADD EFFLUENT :R ON OUTLET Scale: 3/4- • 1' O Rehr to Be. SyRbr Beeln DWegn, Q, fl Doa R NDA -0G791, for Eleven GUld9Bne, OrenCo Systems® Inoorpomted Concrete Riser and Ud to Surface 814 NRWAY AVENUE Cleated V sU1HERUN, N Vent ASSY 974]9-9012qa=('A Riser to grade FAae� (%I) 159-2884 (typ.) TatL mm 1' Vent Piping (800) 348-9843 Tank Adapter (cast or balled) F', TELEPHONE cam b m: caamer (541) 459-4H9 1 1 (55459-2884 Screened IoW Splitter Basin I Joint Outlet (slope at 1/8" per rte Base (Extend 6" Beyond Basin) Top VNW OBSERVATION PIPE SEPTIC TANKS. 1 1 BEDROOMS • 2200 X 1.5 X (30 HOURS RETENTION TIME) 4125 TOTAL MIN GALLONS. 'hon Necharge 4- dis. transport line required) !bunting B a kel 4" PVC PIPES SDR 35 (MIN 1% FALL TO TRENCH) FLOW SPLITTER rowland + broughton architecture and urban design 117s. r rlerah s1. 3377 Neke st IN aspen. m 81611 denier, m 80205 970.514.9008 V 303.308.1373 V 970.544.3473} 303.308.1375/ P.O. Box 2844 Glenwood Springs, CO 81602 Phone 970.618.5033 Fax 303.216.2796 11.11.2010 DEMOLITION PERMIT WESTCLIFFE 1025 STAR MESA DRIVE ASPEN, CO 81611 PROJECT NO 21020 DWG FILE: OWS DETAILS 12.2.2010 REV. 12.29.10 SCALE: NOT TO SCALE 500 -Gallon Concrete Septic Tank with Dosing Siphon Q, fl ' Orenmon—temem e11 AWWA1 AVAe Sal- OlS_ 914A-5012 Concrete Riser and Ud to Surface IEtEPIpxE (%I) 159-4H9 Riser to grade FAae� (%I) 159-2884 1' Vent Piping Tank Adapter (cast or balled) cam b m: caamer SEPTIC TANKS. 1 1 BEDROOMS • 2200 X 1.5 X (30 HOURS RETENTION TIME) 4125 TOTAL MIN GALLONS. 'hon Necharge 4- dis. transport line required) !bunting B a kel 4" PVC PIPES SDR 35 (MIN 1% FALL TO TRENCH) FLOW SPLITTER rowland + broughton architecture and urban design 117s. r rlerah s1. 3377 Neke st IN aspen. m 81611 denier, m 80205 970.514.9008 V 303.308.1373 V 970.544.3473} 303.308.1375/ P.O. Box 2844 Glenwood Springs, CO 81602 Phone 970.618.5033 Fax 303.216.2796 11.11.2010 DEMOLITION PERMIT WESTCLIFFE 1025 STAR MESA DRIVE ASPEN, CO 81611 PROJECT NO 21020 DWG FILE: OWS DETAILS 12.2.2010 REV. 12.29.10 SCALE: NOT TO SCALE 0 N W to r `i I� < z I ul 41 N y N w Z. y y A o vM W _ J cl - F- ro ro r� a ' W >- ti O�Ur�_1 T n UI Qi) J v z 0 N W to r `i R 1 uj p ; I vi � � Q �.l A l g I I ya�y� 3y�wm `! ` Q ~ f WE`'`—'a`—' cn CD LU LU uj } W z `.. JN Q Q S LJ ew ��C) W Qi +! SM ff 2S 3 �-�u3 3oC�uoU Lul > p �- .J Z c a O �=al— �.•� ; i zzoN al ac Uui CD Lw W1�Z = =W Q cmLU �,zl�-W� Zp; M VW)cr.0- W�Oy2 F-' 7 W v � �I =LaJQ'�' Sgwp.�—� < z it N CD lj-aicc C'AI.- ' �cn��j Ql a O W C}i LnI N r -i a I a)I w O O G Q 0 ^J F N 0 r ; N � J 7 0 O 0 a+ E � y to R lTi Z J O Q Q r a j U 0 cr p z CC a } J z O W O :D J O ! Y < rJUUU zoo¢ W NW lJJ LU C 00?C 7- 0 9 1 I� < z I ul 41 N y N Z. y y A o vM O _ J z z - F- ro ro CV W U U j cr z Z , C O�Ur�_1 T n UI Qi) J v z CL H� �r o a r 2 ..- Q CELLJ ": W 2 < )- W W cr J O a w J w LAJ C 1 M f -- w C >� O «< m0 CL d V O s J R 1 uj p ; I vi � � Q �.l A l g I I ya�y� 3y�wm `! ` Q ~ f WE`'`—'a`—' cn CD LU LU uj } W z `.. JN Q Q S LJ ew ��C) W Qi +! SM ff 2S 3 �-�u3 3oC�uoU Lul > p �- .J Z c a O �=al— �.•� ; i zzoN al ac Uui CD Lw W1�Z = =W Q cmLU �,zl�-W� Zp; M VW)cr.0- W�Oy2 F-' 7 W v � �I =LaJQ'�' Sgwp.�—� < z it N CD lj-aicc C'AI.- ' �cn��j Ql a O W C}i LnI N r -i a I a)I w O O G Q 0 ^J F N 0 r ; N � J 7 0 O 0 a+ E � y to R lTi Z J O Q Q r a j U 0 cr p z CC a } J z O W O :D J O ! Y < rJUUU zoo¢ W NW lJJ LU C 00?C 7- 0 9 1 I o I ul 41 N N ZSI N y y A o vM OJ QII - F- ro ro CV W U 81 i N O N1 v � � C U O�Ur�_1 T n UI Qi) I o- w nq 2 H� �r o a t F-- N -j CL CL < W 2 < )- W W cr cu O a w J w W >� O is v a '` '� p a ImZ W r+Om C1 > X d V O z i a• O t ro G > _j C.) U3wW ` ~ p Z LLI a 01 O} I �z, = - y JN =o� } 0 " O r O Ln v > __ M a -.= F- aN Z I�0 =ca�T�Ya• • OV J AQ LU�� cI —1im �Uj N .�` r+ rn _ i 3 C; c_ ck v U- 0.--a -j 81;;; i OZEI z I cc O ¢ m R 1 uj p ; I vi � � Q �.l A l g I I ya�y� 3y�wm `! ` Q ~ f WE`'`—'a`—' cn CD LU LU uj } W z `.. JN Q Q S LJ ew ��C) W Qi +! SM ff 2S 3 �-�u3 3oC�uoU Lul > p �- .J Z c a O �=al— �.•� ; i zzoN al ac Uui CD Lw W1�Z = =W Q cmLU �,zl�-W� Zp; M VW)cr.0- W�Oy2 F-' 7 W v � �I =LaJQ'�' Sgwp.�—� < z it N CD lj-aicc C'AI.- ' �cn��j Ql a O W C}i LnI N r -i a I a)I w O O G Q 0 ^J F N 0 r ; N � J 7 0 O 0 a+ E � y to R lTi Z J O Q Q r a j U 0 cr p z CC a } J z O W O :D J O ! Y < rJUUU zoo¢ W NW lJJ LU C 00?C 7- 0 9 1 I � I ul 41 N N ZSI N N QII l czbl @ 81 i N O N1 a J I M, •-i �"rl 4J UI Qi) N oW I tIl CN z L H� �r o a o Z z -j CL CL < W 2 < )- W W cr } O a w J w R 1 uj p ; I vi � � Q �.l A l g I I ya�y� 3y�wm `! ` Q ~ f WE`'`—'a`—' cn CD LU LU uj } W z `.. JN Q Q S LJ ew ��C) W Qi +! SM ff 2S 3 �-�u3 3oC�uoU Lul > p �- .J Z c a O �=al— �.•� ; i zzoN al ac Uui CD Lw W1�Z = =W Q cmLU �,zl�-W� Zp; M VW)cr.0- W�Oy2 F-' 7 W v � �I =LaJQ'�' Sgwp.�—� < z it N CD lj-aicc C'AI.- ' �cn��j Ql a O W C}i LnI N r -i a I a)I w O O G Q 0 ^J F N 0 r ; N � J 7 0 O 0 a+ E � y to R lTi Z J O Q Q r a j U 0 cr p z CC a } J z O W O :D J O ! Y < rJUUU zoo¢ W NW lJJ LU C 00?C 7- 0 9 1 I � I ul 41 N N ZSI N 4-) Lo I J CO L, 4J r oW ' W j R 1 uj p ; I vi � � Q �.l A l g I I ya�y� 3y�wm `! ` Q ~ f WE`'`—'a`—' cn CD LU LU uj } W z `.. JN Q Q S LJ ew ��C) W Qi +! SM ff 2S 3 �-�u3 3oC�uoU Lul > p �- .J Z c a O �=al— �.•� ; i zzoN al ac Uui CD Lw W1�Z = =W Q cmLU �,zl�-W� Zp; M VW)cr.0- W�Oy2 F-' 7 W v � �I =LaJQ'�' Sgwp.�—� < z it N CD lj-aicc C'AI.- ' �cn��j Ql a O W C}i LnI N r -i a I a)I w O O G Q 0 ^J F N 0 r ; N � J 7 0 O 0 a+ E � y to R lTi Z J O Q Q r a j U 0 cr p z CC a } J z O W O :D J O ! Y < rJUUU zoo¢ W NW lJJ LU C 00?C 7- 0 9 1 I CO M uni i Mj X01 x! z i I 00 CN cI —1im rn LU -, coI -j 81;;; i OZEI z I r ` 7 Z Ln cJ r I� .2 / YC'ALE: 1}12P-0' N %E i EM.T711j, G �RIV WAY TO MWEDIP.ND -VEGD 1 I \ Ex STI sc ue I ! I Ai 1 1 : 2 /D LP T V.FrF. 1 �S��� . REP D j ! I SIlljjj N 1 j i 11 :\ AuTp CogtLr- / REF. CIL , 0BURIED FIRE ( \ Tt SIONTANK - InVL / II 1NING WALL- d STRUCT. j 49l i SPA LUCAIION SITE ROOF ELEVATION ELEVATION HEIGHT-� HEIGHT AS OVE GRADE A 1070.75 1087.00• 1098.75'(28.9) 1087.00' (18.25') B 1061.75' 1087.08' 1089.75•(28.0•) 7087.08(25.33') C 1059.40' 1087.08• 1087.40' (28.0') 108208 (27.68') 0 1088.50 1986.47 1096.50•(28.01) 1086.42.117.92') E 1070.00' 1087.6r 1""2 (zB.o') 1087.67 (17.6r) F 1072.00' 108825• 1100.00' (28.0•) 1 D8825 BUILDING HEIGHT CALCULATIONS ({7,2 SCALE:. N.T.S. !I �' I-I�i broughton Y• I-1' I I I Q if if f /� I ! i 970.504.9006 v 970.544.34731 1 i I ! t 1 AREA OF (ABANDONED) EXISTING SNOWMELT \ I /i NG LEACH F To r !i 1 I ' I i !• / • PROX. -OCA NEµ' LEAQFI FIE�D - -' 1 ; i 1 4 REF: SEPTIC, %f it Iu - II I Al i+ 1 I•,! i 1 \ f , 'I / \fr STING LEACH I !\ TO BE ABANDONED f Ir / �1 i \\ Vi .2 / YC'ALE: 1}12P-0' N %E i EM.T711j, G �RIV WAY TO MWEDIP.ND -VEGD 1 I \ Ex STI sc ue I ! I Ai 1 1 : 2 /D LP T V.FrF. 1 �S��� . REP D j ! I SIlljjj N 1 j i 11 :\ AuTp CogtLr- / REF. CIL , 0BURIED FIRE ( \ Tt SIONTANK - InVL / II 1NING WALL- d STRUCT. j 49l i SPA LUCAIION SITE ROOF ELEVATION ELEVATION HEIGHT-� HEIGHT AS OVE GRADE A 1070.75 1087.00• 1098.75'(28.9) 1087.00' (18.25') B 1061.75' 1087.08' 1089.75•(28.0•) 7087.08(25.33') C 1059.40' 1087.08• 1087.40' (28.0') 108208 (27.68') 0 1088.50 1986.47 1096.50•(28.01) 1086.42.117.92') E 1070.00' 1087.6r 1""2 (zB.o') 1087.67 (17.6r) F 1072.00' 108825• 1100.00' (28.0•) 1 D8825 BUILDING HEIGHT CALCULATIONS ({7,2 SCALE:. N.T.S. LEGEND broughton EXISTING TREES TO REMAIN 117 a. monarch sl. TREES TO BE REMOVED aper, m 81611 REF. TREE REMOVAL SHEET L700 970.504.9006 v 970.544.34731 303.308.1373 v 303.308.1375( AREA OF PROPOSED SNOWMELT AREA OF (ABANDONED) EXISTING SNOWMELT \ I C—.R.ia iaa�a. DEMOLITION PERMIT 11.15.2010 HOA SUBMISSION 11.19.2010 PERMIT/ CONSTRUCTION DOCUMENTS 02.14.2011 CHANGE ORDER WESTCLIFFE 1025 STAR MESA DRIVE ASPEN, CO 81611 ................................. PROJECT NO: 21020 DWG FILE: 21020_A7-1.Ewg SHEET TITLE PROPOSED SITE PLAN RESIDENCE SCALE: 1" = 20'-0" rowland + broughton architecture and urban design 117 a. monarch sl. 3377 Blake ai. 106 aper, m 81611 d—r. m 80205 970.504.9006 v 970.544.34731 303.308.1373 v 303.308.1375( C—.R.ia iaa�a. DEMOLITION PERMIT 11.15.2010 HOA SUBMISSION 11.19.2010 PERMIT/ CONSTRUCTION DOCUMENTS 02.14.2011 CHANGE ORDER WESTCLIFFE 1025 STAR MESA DRIVE ASPEN, CO 81611 ................................. PROJECT NO: 21020 DWG FILE: 21020_A7-1.Ewg SHEET TITLE PROPOSED SITE PLAN RESIDENCE SCALE: 1" = 20'-0" 1 2 3 4 6 g 179'-10" 33'-81/4' 13'-41/4* 38.5 1/2' 42'•11" W ED Z 2 U D : E:A ______________�___ MASTERBA I .. — — — — — — — _ 7 r------- 1 r-- --1 -- --1 ! 104 i Iz-- ---M-- ----- — -- --- ---- -- �4 IrI - BEMDGQARD1S2EOT0SETR r/.n�7".!.fti119 � Z�. LJ MAS t� A�/4l/,.`c�:`_%•%�_��' =� � - —I --s:=� _-_ I {II�TJER CLOSET ------ — .. __.. — C u los"S — - —._,--- ----- --,BAOM3gry0p HALL MASTER .... �,iBED ;_ I J; ' ! _ _ •._ _ _ �2i'�; BREAKFAST 109 I _....— 707 103 Ic�—I I BEDROOM 4 BEDROOM 5 a1 DR. BEDROOM,6 II OUO� BA ______ D Z jX17 M: .. i PA 229 V I f-'." 102uv...:a `$�I'Al L------ N � 130 13 I m --------------� D.6 �4 I SITTING HALL I SEATING NOOK R 128 112 I T.o I 2 STAT OPEN TO SITTING _ r---1 r---1 r---1 E — u, k4—H STAIR I I °M 1z5 BATH g I ^K y' T : I I tf e Tt rowland + broughton architecture and urban design 117 s. monarch sL 3377 bike sl, 106 aspen, m 81611 4emer. m 80205 970.544.9006 v 303.308.1373 v 970.544.34731 303 308.1375 t _........... _....... ... __................................................... C.—dwo W- 11.11.2010 DEMOLITION PERMIT 11.15.2010 HOA SUBMISSION 11.19.2010 PERMIT/ CONSTRUCTION DOCUMENTS 02.14.2011 CHANGE ORDER WESTCLIFFE 1025 STAR MESA DRIVE ASPEN, CO 81611 ................................. PROJECT NO: 21020 DWG FILE: 21020_A2.7.d. g SHEETTITLE PROPOSED MAIN LEVEL REFERENCE PLAN SCALE: 118"= V-0" A2.1 --- ------ 0 I I I I I - I I `f r: I I I I I 02DF MA GE CRAWL SPACE D,5 D17 I i I T — TIM` e R L D.6 o,B 06 — __. 1. ooz i �_.-._. --— � — BEDROOM 2 — H — F.2 - I I I E b I I I I I I I I I I L°__ I I I I I I I I I I I I I I I x �I I I I 13'-0 1l4" 38'-51/2' — — LOWER LEVEL REFERENCE PLAN I I URbEgGAIk{{ I r— PLAN TRUE I I I I I Ili I/ll I I I w SPACE 018 G I I AV r: I I I I I 02DF MA GE 021 D17 I i I I I ENTRY 'E — TIM` e R L D14 ' o,B 06 BED __. 1. ooz i �_.-._. --— � — BEDROOM 2 — _ — F.2 - I I I — b I I I I I I I I I I L°__ I I I I I I I I I I I I I I I x �I I I I w SPACE 018 G I I AV —0 WINE 1 BILLARDS 02DF MA GE 021 D17 — r -- e R L D14 ' SPACE D79 BATH BED __. 1. ooz i �_.-._. --— � — BEDROOM 2 — _ — --- ---------- ---------J - I I I b I I I I I I I I I I L°__ I I I I I I I I I I I I I I I x �I I I I 13'-0 1l4" 38'-51/2' — — I I CRAWL 000COLoo o= SPACE e013 e CRAWL SPACE D17 CRAWL CRAWL SPACE R L D14 ' SPACE D79 I I MECHJ CRAWL I 010 " I 0 0 I I I NEW WALL TO RETAIN FOAM BLOCK I m, owland + broughton rchitecture and urban design 17 a.monarch aL 3377 Nake el, 1D6 Ps s , m 81811 ""'m 80205 10.504.9006 v 303.308.1373 v 10.504.34731 303.308.13751 1.11.2010 MOLITION PERMIT 1.15.2010 DA SUBMISSION 1.19.2010 :RMIT / CONSTRUCTION DOCUMENTS 2.14.2011 iANGE ORDER JESTCLIFFE )25 STAR MESA DRIVE SPEN, CO 81611 :OJECT NO'. 320 VG FILE )20_A2-0.tla9 EET T TLE ROPOSED OWER LEVEL ,EFERENCE PLAN :ALE: 1/8"- V-0" 000COLoo o= I — CRAWL SPACE D79 I I — --- ---------- ---------J I I I PROPOSED LOWER LEVEL REFERENCE PLAN A2.0 SCALE 1/6"-1•-0" PLAN TRUE NORTH NORTH 42'-11' 27'-6" 23'-11" 7 V 5 6 m, owland + broughton rchitecture and urban design 17 a.monarch aL 3377 Nake el, 1D6 Ps s , m 81811 ""'m 80205 10.504.9006 v 303.308.1373 v 10.504.34731 303.308.13751 1.11.2010 MOLITION PERMIT 1.15.2010 DA SUBMISSION 1.19.2010 :RMIT / CONSTRUCTION DOCUMENTS 2.14.2011 iANGE ORDER JESTCLIFFE )25 STAR MESA DRIVE SPEN, CO 81611 :OJECT NO'. 320 VG FILE )20_A2-0.tla9 EET T TLE ROPOSED OWER LEVEL ,EFERENCE PLAN :ALE: 1/8"- V-0" W2 I m - wx. yr R16 row--_ rill" - Pro 446;1 �- W2 I m - wx. yr R16 raw, r _ i. N y+ if j * '�~? ys'1�• dam` .c � 'fes � t� y� � ` • • -� 171 � `, � h `� . tl:.`!,�► ✓ .'�`` ' �, �'' '� m F \ * "N' Jo 19 , mm� '17 PAP w . war �. 71 }...: r � . .. I w s s z f M 4 if ry x - . so..,, { moi" x. 8 `` � '.L..'�� • "4 A .. .AI. .K r r� .K r �: :' ;� � ,�� -� ^�. 3 � mow' t,� . ,.:A_ ,�, � a, f c �_ ...��.� . i �� � � + � ` '4�� - :�- . � �... ^Fh !l��.. ... ... -,. ,� t Y v � e r a � � � �� ...m ,.. ' c1 �e'As���it ���� -.. T I!':d 1 �'p � • � x _. _ � � /r tib. w �* �, ;� � � �,. 4 1 _.C. m Rolf Ne 36,30 W S 79 - I- 286.81 PROPERTY LINE (TYP) EXISTING CONTOUR (TYP.) \ PROPOSED NTOU \ .J EXISTING DITCH \ �K \ IIIII ► �, RAINAGd SWALE I ( p) 0 BUILDING ENVELOPE (TYP.) \ � � V VC SEWER�P/P \ W r IIIII ASTM 2729, SL DPE 1 . bo 1/4i PER F001 I I \ I \ PROVIDE �N UT I 01FEL LITINE DETAIL E. r I I I P` 1500 GAL SE TI J gyp\ i ISTR, UTION 901 t ROVI E CL N T I \ A� I 00 DIRECTION OF DPA/N4C FL I �! �,�,,,R /% �cp I 1 \ 11 I I F.F�8154.50' o \ 1 —B 00 CONSTRUCTION NOTES,• S DR I RE /DENC / 1. BED AND SEPTIC TANK MAY BE FIELD ADJUSTED PROVIDED TO BEST FIT THE SITE PROVIDED MINIMUM SETBACK REQUIREMENTS ARE MET AND ENGINEER AND PITKIN COUNTY HEALTH OMCEER ARE NOTIFIED. 2. ONLY STRAIGHT RUNS OF SEWER LINE ARE ALLOWED. LOCATE CLEANOUT AT EACH HORIZONTAL AND/OR VERTICAL CHANGE IN DIRECTION. Cb 00 SITE PLA__N_ SCALE- I" = 50' GENERAL NOTES: 1. All materials, installation practices, setback requirements, etc., shall comply with the Pitkin County Individual Sewage Disposal System Regulations. 2. The E. T. bed shall be constructed so that the bottom is level f/-0.1 inches. Place bed in natural ground; no portion of the bed shall be placed in fill. J. Provide adequate surface water diversion to assure that runoff does not enter the evapo—transpiration bed. 4. Stone shall be 1/2" to 2-1/2" screened rock. 5. Sand shall be 0.5 to 7.0 mm effective size with a uniformity coefficient of 4 or less. 6. The recommended bed seeding is blue grass at 4 to 6 lbs/100 sq. ft. All other areas disturbed by construction shall be reseeded with native grasses to prevent erosion. 7. The location of the bed may be adjusted in the field to better fit the site, provided all setbacks are met. S. Piping in system shall be stanard perforated sewer pipe. ASTM 2729—Sewer and Drain Leachfie/d Pipe. 9. 4" PVC tees should not be glued to enable observations of water level in system and to remove excess salts accumulation or surplus water, if necessary. 10. Use risers as needed to bring septic tank access hatch within 6" of finished grade. FLOw TO TAIN/FIEL D 11. Cast iron pipe of equal strength or other pipe properly supported to prevent failure by settling shall extend from tank for a distance of at /east five feet (5) from the inlet and outlet ends. 12. The Contractor and Owner shall take whatever measures are necessary to assure that (a) septic tank and sewer lines are completely water tight, and (b) the system is to be installed to prevent freezing of all pressure and gravity sewer lines. 13. The Pitkin County Environmental Health Department and the Engineer shall be notified when construction commences and kept abreast of the construction progress so that sufficient inspection can be performed to assure conformance with these plans. Provide a minimum of 48 hours notice to each. 14. Mapping provided by client, supe/ented by engineer. O N W 0 0 M COVCRETE REINFORCED WITy 6-6 70-10 MESH 1 INLET 7 OUTLETS Z 2.0" in DISTRIBUTION BOX EXISTING GRADE 2:1 SLOPE FINISHED GRADE PROVIDE SWALE TODIVERT7 RUN-OFF AROUND E. T. BED LAP LINER I' CLEAN-OUT DETAIL DESIGN CAL CULA TIONS 1. DETERMINE DESIGN FL OW 5 BEDROOM HOME, 2 PFRSONSi'BEDROOM, 75 GALLONS/PERSON/DAY Q = 5 * 2 * 75 = 750 GPD 2. SEPTIC TANK SIZE FOR 2 - BEDROOV HOME = 1500 GALLONS J. ALLOWABLE LOADING RATES: FOR EVAPO—TRANSPIRATION USE STANDARD ET RATE FROM 32 PAN OF 0. 135 GAL L ONS/S. F./DA Y 4. DETERMINE BED SIZE - AREA = %.135 = 5556 S. F. USE 2-30' X 93' BEDS,= EFFECTIVE AREA = 5580 S.F. 259' REDUCTION IN FIELD AREA FOR USE OF WATER SAVINGS DEVICES, WOULD RESULT IN A REQUIRED FIELD AREA OF 4167 S. F. suRVEroR SCyMUESER GORDON MEYER INC. WESCLIFFE PARCEL STAR MESA a R sVMNEMS C100f GRAND AVENUE; .SUMF 2-,E oo,��' RESIDENCE GLENWOOD SPRINGS. COLORADO 81601 SCHAIM SER (j0.3) .945-1004 (FAX.) P45--5948 OR.DON W)ER ,ASPEN, COLDWO (kJ) 92.5-6727 PITKIN COUNTY COLORADO 3' a BOTTOM OF BED CONSTRUCTED IN NATURAL GROUND, BELOW TOPSOIL PROVIDE 10 MIL. PVC Ll 4" SOLID WALL PVC SLOPE 0"/FT. 4" PVC FROM SEPTIC TANK FLOW FROM HOUSE/TANK REVISION 30' E' 9 7" WASHLO SAND -` 30779M OF BED SHALL BE LEVEL 0. 1 f, SCARIFY BEFCRE PLACING ROCK SECTION A A SCALE: 1"= 3' 62' 9 SANDY TOPSOIL VARIES FROM 6" AT CENTER TO 2" AT EDGES 4" PERFORATED PVC SLOPE 0"/FT. (T3P.) 13" OF 1/2" TO 2 -112 - CLEAN ROCK IVA M/RAF/ FABRIC OR 4" OF STRAW 2:1 SL OPE LAP LINER 7' 71 �o 4" PERFORATED PVC SLOPE 0"/FT. (TYP.) �o AIR VENT (2 RE -OD) w SEL DETAIL a �: EVAPO- TRANSPIRA TION BED DETAIL SCALE: 1"= 10' ti SANDY TOPSOIL WiR/ES , PnA./ S" AT r'FA1, .='R SCALE.• 7"= 4" TEE, DO NOT GLUE 4" AIR VENT DATE 1 BY INDI VID UAL ,SIFWA GL DI,SPD,SAL S'Y,S'TEM 1 Job No. 90214 Drawn by: DJC Date. 9120/91 APPr by JSS 2OF] File: MOSS/SDS :e 0,4�✓ Job No. 90214 Drawn by: DJC Date. 9120/91 APPr by JSS 2OF] File: MOSS/SDS