Loading...
HomeMy WebLinkAboutpitkin.eh.264324301002 (2001) (OWTS 2)Permit # 01082 Pitkin County Environmental Health Department Permit for an Individual Sewage Disposal System 0405 Castle Ck Rd, Aspen, Colorado 81611 Phone 970-920-5070 / FAX 970-920-5077 , Parcel ID # 2643-243*-Qlll� Type of permit New( X ) Repair( ) Addition to Fiouse( ) Name of Owner Two Mile Ranch LLC -- 2 residences Elliot & Yearyd�- Street Address 3448 Woody Ck Road Property legal description Size of lot 245 acres Total square footage of the house Each < 6,000 sq ft Water source To be deterrn_ in—ad private well or infiltration gallery # of bedrooms in house 5+4 # of offices, lofts & similar sized rooms in house Caretaker unit # of bedrooms in caretaker unit Total square footage of the caretaker unit # of offices, lofts & similar sized roorns in caretaker unit Designed for what # rooms (list) 9 NINE (Yeary Residence 4 Bedrooms, Elliot Residpnce 5 bedrooms) Permit information Designed by Church & Associs'zs, Inc., Mailing Address 4501 Wadsworth Blvd., Wheat Ridge, CO 80033 Perc rate 17 Profile hole depth 8 ft Depth to groundwater or bedrock +8 ft Septic tank capacity 3150 gallons Absorption area See engineer design Comments This permit is issued for an experimental Drip Irrigation System designed by Church and Associates and dated October 1, 2001. Any changes must be approved by this department and the design engineer prior to them being made. Requirements in Section 4-20 of Pitkin County ISDS Regulations must be met and must be in accordance to Resolution # 99-34 for Experimental Drip Irrigation Systems. Minimum horizontal distances between components of the system and physical features shall conform to the Pitkin County ISDS regulations. Zone of Influence distances must be met since there will be 9 residences and 2 buildings on one property. This department does not endorse any brand of products. The engineer must do a final inspection of the installation and submit an as -built letter to this department. This department must also be called for an inspection with a minimum of 48 hours advanced notice. Permit approved by: e w - Date: I / ,4�J ryV-4— 4UAI, P,"44%_ , t P,. t l Plans and specifications of the proposed individual sewage disposal system have been reviewed a pare considered satisfactory. Permission is hereby granted to the owner or the agent to perform the work indicated in accordance with the Pitkin County ISDS Regulation in effect at the time of issue. This permit becomes invalid 6 months from the date that the permit was issued unless system construction has commenced or an extension has been approved in writing by the Department. As-built drawings must be included with this permit before the final approval will be issued. Installer: a Final Inspection Approval:��� J/ 24, &1 Pitkin County Environmental Health Department 0405 Castle Creek Rd, Suite 10, Aspen, CO 81611 FAFAX/MEMOIL ] TO: Phone: Fax Phone: CC: q7 Is IREMARKS: ❑ Urgent Y-1 For your review Date: 5" / /0/ G -I— Number Number of pages including cover sheet: FROM: Nancy MacKenzie Phone: 970-920-5076 Fax Phone: 970-920-5077 E-mail: nancym ci.aspen.co.us ❑ Reply ASAP ❑ Please Comment Pitkin County Environmental Health Department 0405 Castle Creek Rd. Suite 10. Aspen, CO 81611 FAX/MEMO TO: Phone: Fax Phone: CC: Holly Hamilton 920-4629 Ed Church Date: 10/22/01 Number of pages including cover sheet: 2 FROM: Nancy MacKenzie Phone: 970-920-5076 Fax Phone: 970-920-5077 E-mail: nancyra@ci.aspen.co.us I REMARKS: ❑ Urgent ❑ For your review ❑ Reply ASAP ❑ Please Comment On 10/15/01 1 discussed with Tim Petz the concerns I had with OWS 1 and OWS 2. 1 will fax you my notes on OWS 1, though I did discuss them on the phone directly. The concerns that I discussed regarding OWS2 are: 1) the zone of influence 2) No existing wells or water sources or water lines are indicated to confirm that the system components meet state & county setback requirements. This is the same concern I expressed with OWS 1. e DRTP IRRIGATION CHECK ITEMS NEEDED BEFORE ISSUING THE PERMIT V August 10, 1999 letter signed by owner stating that owner understands the condition of Resolution #99-34 Approved Soil Moisture Monitoring Plan from Engineer (i.e., Ed Church), if a "water balance" 'method of calculating waste load is applied. There must be room for a backup system in case this experimental system fails. A filter after the final septic tank is required. _ Site of system must be similar to that required for an ET system - not in a shaded north -facing valley, but in an area open to sunshine and breezes enough days per year and hours per day. DETAILS NEEDED IN THE PERMIT Permit must be issued in the name(s) of the legal owners of the property involved and must contain an accurate description of the property Permit must display the requirements in Section 4- 20 of regs, "Experimental Systems". The permit issued for a Drip Irrigation system shall be recorded in real estate records for the property. For 5 years in January of each year, the applicant (owner) must provide a written report to EH Dept.documenting maintenance, soil moisture data if required.. August 10, 1999 ASPEN - PITKIN ENVIRONMENTAL HEALTH DEPARTMENT We have been notified that you are going to install a Drip Irrigation sewage'disposal system for your property and we want to be sure that you, the property owner, understand what this means. This is an alternative method of wastewater disposal not provided for in the Pitkin County Regulations. As such, it has been declared an experimental system and the installation of a total of eighteen such systems have been approved. Attached is a copy of Resolution #99-34 which was adopted by the Pitkin County. Board of Commissioners, acting as the Pitkin County Board of.Health. We request that you read the conditions of the resolution and sign the bottom of this letter stating that you understand these conditions. We have. taken these precautions because Drip Irrigation is an experimental system in this area. Several hundred of these systems have been installed on the Eastern . Slope. However, we do not have historical data to know how the system will perform at this altitude and in the extreme and varying weather conditions we experience. Some conditions that must be met before we can issue your septic permit are as follows: • If a "water balance " method of calculating waste load is applied, a monitoring plan must be submitted to determine saturation status of soils. After installation, you must provide a written report to this Department documenting maintenance on the 'system for a period of five years, and submit it to this Department in Janu. Bch year. I understand Resolution #99-34 .,M wa,d Coq (ACL 0 Address of Property 130 SOUTH GALENA STREET • ASPEN, COLORADO 81611-1975 • PHONE 970.920.5070 • FAx 970.920.5197 Printed on Recycled Paper Oct 22 01 09:57a P•1 0 4501 Wadsworth Blvd. Wheat Ridge, CO. 80033 Castfe Rock 303-660-4358 FAX 303-663-1249 Pine Junction 303-816-1456 FAX 303-816-1942 Loveland 97D-663-2124 FAX 97MG3-2181 To: CHURCH & ASSOCIATES, INC. Phone: 303463-9317 Fax: ' 303-4+63-9321 Frone Pn) C4'a� Company ! ✓ Date: %U - ZZ Fax No. 0 Urgent ❑ For Review 0 A Requested ❑ Please Reply CC: Fax: Marc: )11-71-, . . - ` L PAGES ( Z ) ONCLUDiNG VER SHEET) Oct 22 01 09:58a p•2 CHURCH & Associates, Inc. ENGINEERS & GEOLOGISTS October 16, 2001 BEACH Environmental LLC 715 West Main, Suite 304 Aspen, Colorado 81611 Subject- OWS 2 Zone of Influence TWO MILE RANCH, OWS 2 Pitkin County, Colorado Job No. 13288 Gentlemen, Per a telephone conversation with Nancy MacKenzie of APEHD, we have prepared an "Zone of Influence" plan with respect to OWS 2. The purpose of the plan is to indicate whether the setbacks from various OWS are within the influence of each other_ The setback for OWS 1 based on the 2712.5 GPD loading is 237 feet. The setback for OWS 2 based on a 3150 GPD loading is 272 feet. Setbacks from the fields are presented on Figure 1. As indicated on Figure 1, the setbacks and therefore zones of influence do not intersect. The systems are therefore considered independent. If there are questions or if we can be of further service, please call. The project manager is Tim Petz. Sincerely, CHURCH & O. Church, EOC/trp 3 copies sent Copy to Nancy MacKenzie, Aspen/Pitkin Environmental Health Department Copy to Fenton Construction, ATTN.- Holly Hamilton 117 Louth Monarch Moen, CO 81611 UtNVLH 4501 Wadsworth Boulevard Wheat Ridge, CO 80033 CASTLE ROCK 303.660.4358 303.463.9317 Fax: 303.463.9321 EVERGREEN 003.883.24 LOVELANDO924 WESTERN SLOPE 970.948 SS03 CHURCH & Associates, Inc. ENGINEERS & GEOLOGISTS August 27, 2002 BEACH Environmental LLC Attn: Gary Beach 715 West Main Street Aspen, Colorado, 81611 Subject: Installation Observation, OWS #2 Two We Ranch Pitkin County, Colorado Job No. 13288W Mr. Beach, As requested, we observed the installation of the onsite wastewater system (OWS) for the subject site on August 13, 14, and 26, 2002. The OWS was designed under our Job No. 13288W, dated October 1, 2001. The installation included two 2000 -gallon single -compartment precast concrete septic tanks with dual pumps, a four outlet automatic distributing valve, and four AX20 Advantex"m pods followed by one 1000 - gallon lift station with dual pumps. The drain field consisted of six 12 x 90 feet drip irrigation field sections for a total area of 6480 square feet. ABS pipe was used in the OWS installation. Distribution valves were installed to distribute effluent. The pump, alarm, and filters were in place at the time of our third site visit. The construction manager, Jeff Spalding, with Fenton Construction, may activate pumping system at his discretion. The components of the OWS were installed in conformance with our plans and specifications. If there are questions or if we may be of further service, please ca CHURCH and Associates, Inc. Timothy R. Petz Project Manager EOC/trp/erb 4 copies sent Copy to PCEHD, Attn: Nancy MacKenzie, via FED EX Revi Edw j ")'7'f .;Zao/ DENVER 4501 Wadswor^,h Boulevard Wheat Ridge, CO 80033 CASTLE ROCK 303.660.4358 303.463.9317 Fax: 303.463.9321 EVERGREEN 303.6 LOVELAND 970.66363.1455 .2124 WESTERN SLOPE 970.948.5803 TWO MILE RANCH, OW #2 S23, T9S, R85W PITKIN COUNTY, COLORADO'; Npp �m oY 1 IX--. 1 JOB NO. 13288W 6 RICULTI BARN k IST 0 T O 2000-G LON, SING E-COMPARTf�EN v00 r _ P ECAST C CRETE SE TIC TANKS1 . 0.5 A RE BUILD[ C NNECTE MID -TANK ITH DUAL o ENV )PE 1 gyp,, I A TERN, I G PUMPS, ONE FOUR OL4LET'[ - �' A TOMATI DISTRIBUT NG VALVE, XISTING �tCiVANTEX;" TREATMENT SYS AND OLE BARN l '�� BY 0 Iq-GAEL0N-L�IONI PVU W DU L ALTERNATING PULPS TO DRIP FIEL ` ODY z z z � j CREEK "'�°09 ,%* -.�_. - ~ WOODY f CREEK f.� � tet" � �. � �' / '.'.+.,, d`" ' f�''�• e yd t ffff f 4 F f,P P IL P- 2" HDPE Pu INE `_.-� -.. _--�'-_..__.. .6 ACRE BUILDING\`,,, 211 b 12' X 94' SE IONS IRAIGATfON ELD F67 `480SF 1NILTRAT. m AS -BUILT DRAWING_ ..nwrnr ��' E April 28, 2005 Circle R Ranch P.O. Box 275 Woody Creek, CO 801656 Attn: Jay Yeary Subject: Water Softener Backwash Circle R. Ranch, OWS 4 Pitkin County, Colorado Job No. 13288W Mr. Yeary, 2(o q 3 - Z35 4-0 1 —OC4,, This letter is to confirm that there is risk of discharge water treatment backwash to the onsite wastewater system (OWS). Our experience is that the discharge of the backwash brine from a water treatment system can cause an early failure of the field and can affect the treatment process within the AdvanTex system. Based on a telephone conversation with Angela Helliwell of SCG Enterprises, Inc., she indicated one system at Circle R Ranch already has backwash discharge to the AdvanTex system and the treatment process is not functioning properly. Other systems without backwash are functioning properly. Based on telephone conversations with Paul Jacobs and Dean Derosier of McLaughlin Rincon, they are concerned about shallow ground water. It is our understanding there is a "drywell" for the backwash at this time but water ponds. It is suggested the drywell be enlarged. We have also had conversations with Carla Block of the Pitkin County Environmental Health Department (PCEHD) with regard to discharge of water softener backwash. PCEHD does not require a permit for a drywell. PCEHD is aware of problems where water treatment backwash is discharge to OWS. In summary, we strongly advise against discharging backwash from the water treatment system to the OWS. If there needs to be a meeting with respect to this, please call. If there are questions, please call. Sincerely, CHURCH & Associates, a division of InTEC of Denver Metro, LLC. Reviewed by: Edward O. Church, P.E. 3 copies sent Copy to: SCG Enterprises, Attn: Angela Howell McLaughlin Rincon, I I IP AABC, Aspen, C) 81611 Robert Johnson via email Pitkin County Environment Health, ATTN: Carla Block Page 2 OWS 4, Job NO. 13288W CHURCH & Associates, Inc. ENGINEERS & GEOLOGISTS October 26, 2001 BEACH Environmental LLC 715 West Main, Suite 304 Aspen, Colorado 81611 Subject: Water Source Clarifications and Setback Requirements TWO MILE RANCH, OWS 1 acrid OWS 2 Pitkin County, Colorado Job No. 13288W Gentlemen, As requested, we have provided figures for OWS 1 and OWS 2 regarding water lines and water sources. These figures must replace figures in OWS 1 design and OWS 2 design dated October 15, 2001 and October 1, 2001 respectively. Based on topographic positioning of the irrigation ditches, the mounded drain field and use of Advantex TM secondary treatment with nitrogen reduction, we believe the setback distance can be reduced from 187 feet to 125 feet to down -gradient ditches and to 75 feet to up -gradient ditches. We believe contamination of the ditches by the OWS will be prevented. The temporary water treatment facility meets all required setbacks. The temporary water treatment facility is to be moved further up Woody Creek in 2002. Water lines, when closer than 10 feet to sewer lines, must be sleeved with Schedule 40 HDPE pipe. If there are questions or if we can be of further service, please call. The project manager is Tim Petz. Sincerely, CHURCH & Associates,0, cys��� G9t c, 172 Edward O. Church P.E. EOC/trp/erb 2 copies sent, via Priority Mail Copy sent to APEHD, Attn: Nancy MacKenzie, via Fed Ex DENVER 4501 Wadsworth Boulevard Wheat Ridge, CO 80033 303.463.9317 Fax: 303.463.9321 CASTLE ROCK 303.660.4358 EVERGREEN 303.816.1455 LOVELAND 970.663.2124 WESTERN SLOPE 970.948.5803 0c z m M X - M n 4- O NEW ou 0 M m -4 m m -4 1pi En 9 g' I 0 0'4 4;uO mp a MI E rm K �D t>z rn (n I 0 0'4 4;uO mp a MI E rm K �D ID Z vo f r ,! m rT HA g OZOZ *OZr UMO O ) Z Cl)�z0 m v 9 Onm4- —0 0 r0Wi -n �rn >�Eg ;u mm m 3 Pn m m v �m a� my N wF x m /i CA MA ( D J '-,TWO MILE RANCH, OWS #2 S231 TOS, R85W PITKIN COUNTY, COLORADO' RICULTI BARN iw JO 13288 212'` ETBA;K FROM CREED 00 EXISTING ED - VW4TEX'w� REATM T YSTEM -DE-rAIL r FIGURE.. UNDER ROA IY� HDPE HDPE SE ER LINE o (S 0 UNDER 01 Vi 2" Wf4 HDPE PU�INE ��,--10.6 ACREJ BUILDING 9��ffE PLAN, LOCATION OF PERCOLATION HOLES, AND LOCATION - OF PROPOSED OWS m --s I SM24 MAR AM w Ls Psma Mm -1 10/01/01 FIGURE I (o I' UTILITY CORRI UNDER R 00 T 0 2000 -GALLON, SINGLE -COMPARTMENT, 0 CAST CONCRETE SEPTIC TANKS 0 0.5 NNECTE�l MID -TANK WITH DUAL EN TERNATI,NG PUMPS, ONE FOUR 0 LET 4, TOMATIC DISTRIBUTING VALVE, iD VANTEX�w TREATMENT SYS LOWE BY - i STATION PVU W DU L ALTERNATING PUf PS TO DRIP FIEL 70, 9 HDPE PU�INE ��,--10.6 ACREJ BUILDING 9��ffE PLAN, LOCATION OF PERCOLATION HOLES, AND LOCATION - OF PROPOSED OWS m --s I SM24 MAR AM w Ls Psma Mm -1 10/01/01 FIGURE I -- FeCLic® tISAAirbill ak9 8 Express Member 256 3504 3488 1 From .-,.. ,oncanbereme� , _ ..,".r._-tfsrewr_ Date . FedEx Tracking Number 8251335043488 W 2 J W W a C— Z W a_ V W Cr Sender's J 9(93-93 q�" Name 14 �� Phone wJ CHURCH 3; ASSOCIATES INC 4509 WADSWORTH f3lMVO WHEAT RIDOF 2 Your Internal Billing Reference co 80033 TO Na Recipient's s ty A %L r",Irr Phone 170 9V`t'�i. -. CompanyCOmpany AV F_ HD Address C✓ 9C)s T'Siti `.-17vLE. r- ''^C..Ab To"HOLD"at FedEx cation, prim FedEx address. We canned: deliver to P.O. boxes or P.O. ZIP codes. SU1,1 c) City � t.� State `C) ZIP C �NWIININIIIIiIIIIInNIIinIIIIIIIwIIII��� elm 0215 I.O. No. 4a Express Package Service Packages up to 15O/bs. Delivery commitment maybe later m some areas. ❑ FedEx Priority Overnight TSAdExStanftm,,n Overnight ❑ FedEx FirstOvernight Next business morning ext business afternoon Earliest to select locations morning delivery to select locations ❑ FedEx May* ❑ FedEx [ xpress Saver* Second business day Third business day ' FedEx EnvelopelLetter Hate not available Minimum charge: One -pound rate 4b Express Freight Service Packaghesoverr5Olbs. Delivery commitment may elaterinsomeareas. ❑ FedEx IDay Freight" ❑ FedEx 2O ay Freight E]FedEx3DayFreight Next business y Secondbusiness day Third business y Packaging Declared value lirril ❑ QEx Envelope/Letter* F-1 FedEx Pak* ❑ Other Pkg. j Includes FedEx Box, FedEx Incl-dand cust rnerBox, pkg.Fed ` 6 Special Handling SATURDAYDelivery El Ave lableonlyft, rod ExPrmrrty ❑ SUNDAYOeliveryHOLD Available FedlExP,omy❑ Weekday at FedExLoeation HOLD FadSat El HOLD Ex Location Overnight and Fed Ex 20ay plytor Ova,Wato select ZIP codes Notavailablevdlh Available only for FedEx Pi to select ZIP co des FedEx Film Overnight Ovemight and FedExMay toselectlocations Does this shipment contain dangerous goods? No ❑Yes ❑ Yes ❑ DrYlce x As per attached Shipper's Declaration Dry ce, 9, UN 1845 kg Shippefs Deck'niian not required Dangerous Goods cannot be shipped in FedEx packaging. ❑ Cargo Aircraft Only % ymetrt Blllb>:Obtain Recip. t Card No. below. ----� Acct No. Sender _ ❑ Recipient ElThird Parry E] Credit Card E]CaslVCheck 011737791 16 By signing yodrmdhodze usto deliver this slrpmemwithom obtaining a signatet and agree to indemndy and hold us harmless from any resulting claims. Questions? Visit our Web site at www.fedieat.com or call 1.800•Go"Fed 1800)483-3339. SRP 0101 •Rei. Data 7/00•Partt1559125•0199E 2000 Fed& -PRINTED IN u S A. 402 omY^�.�--- - UQ256 3504 3488 V,11110-FORM AM TRK# f'" j Peel and Sticl 't . 1. Complete front pag 1611 -CO-US �r 2. Retain "Sender's C ! AGEAV 3. Remove label backi 4. Adhere Airbill to fro I Please DO NOT rem PEEL FROM THIS CORNER. ,. J CHURCH & Associates, Inc. ENGINEERS & GEOLOGISTS October 1, 2001 BEACH Environmental LLC 715 West Main, Suite 304 Aspen, Colorado 81611 Subject: Subsurface Investigation and OWS Design TWO MILE RANCH, OWS 2 Pitkin County, Colorado Job No. 13288 Gentlemen, As requested, we have investigated subsurface conditions and prepared an Onsite Wastewater System (OWS) design for the site. Our firm investigated subsurface conditions on September 26, 2001. SITE CONDITIONS The investigated site includes two building envelopes at the Two Mile Ranch as indicated on Figure 1. The subject site is located in a rural area where OWS are required. The slope at the proposed drain field is 5 percent to the northwest. There is a good cover of native grasses at the proposed field location. PROPOSED CONSTRUCTION The sites to be served include two building envelopes, which are 0.6 -acre and 0.7 -acre in size as presented on Figure 1. The average daily sewage load is 1800 gallons per day (GPD) as presented in TABLE I below per Aspen/Pitkin Environmental Health Department (APEHD) regulations. The peak loading is 3150 GPD. There are specific plans for the home at the 0.7 -acre parcel, but no specific plans for the 0.6 - acre parcel. The drain field is proposed to the southeast of the 0.7 -acre building envelope, which will be 212+ feet from Woody Creek The property will be served water by several onsite wells located 272+ feet 7 from the drain field. Water is collected and treated before distribution to individual structures. TABLE I, SUMMARY OF WASTEWATER LOADING STRUCTURE AREA, SF BEDROOMS AVERAGE q., GPD PEAK Q, GPD 0.7 Acre Lot <6000 5 1000 1750 0.6 Acre Lot <6000 4 800 1400 TOTAL n. a. n. a. 1800 GPD 3150 GPD OWS 2 is proposed to include advanced treatment. A distance of 272 feet is required between the field and well per APEHD regulations and 212 feet to creeks for the 3150 GPD wastewater flow. All setback distances can be met. DENVER 4501 Wadsworth Boulevard Wheat Ridge, CO 80033 CASTLE ROCK 303.660.4358 303.463.9317 Fax: 303.463.9321 EVERGREEN 303.816.1455 LOVELAND 970.663.2124 W A0 OWS 2 Design Job No. 13288 Page 2 The owners have requested that PVC pipe not be used in construction at the property. HDPE pipe has been substituted for PVC in specifications. In several details we have not changed the PVC description, but we have requested PVC components to be substituted with HDPE. SUBSURFACE CONDITIONS Subsurface conditions were investigated by excavating a test pit and four percolation holes, 26 to 38 inches deep, at the locations indicated on Figure 1. Subsurface materials consisted of 1 foot of silty sand topsoil underlain to 9 feet by reddish brown silty sand with random cobbles. No ground water or bedrock was encountered during the excavation. The percolation test indicates rates from 10 to 27 minutes per inch (MPI). The average percolation rate is 17 NIDI. Percolation data is included as Figure 5. EXPERIMENTAL DRIP IRRIGATION SYSTEM The proposed drip irrigation (wallow trench) OWS has been authorized as an experimental OWS in Pitkin County. As a part of the authorization, there are conditions, which are not typical of other permits in Pitkin County. The conditions include: a. the applicant must commit to follow recommendations of the Department and the design engineer, b. a backup system design is required, c. monitoring of soil saturation and an annual report is required and must be reported for 5 years, d. the site must be reviewed for solar and wind exposure. You will have to agree to the following conditions: 1. you must agree to the terms of the permit; 2. a backup design is an ETA bed design in the same area and 3. monitoring as described later in this letter will be required which will include an annual report as described in Item C. The site has been reviewed as described under Site Conditions and found suitable for installation of a drip -irrigation OWS. Twelve shallow trench drip irrigation systems have been installed and are performing properly in Pitkin County, so we do not anticipate problems with installation or performance ofthe OWS. There are 3500+ successful drip irrigation OWS operating in Colorado. It is our understanding the experimental status of drip irrigation OWS is being reviewed by APEHD staff. We have discussed the status with them and hopefully experimental requirements will not apply to this application. Typically drip irrigation systems are installed where there is poor percolation. Because good percolation rates were found at this site a backup drain field design was not prepared. A backup field could be chamber trenches. RECOMMENDATIONS The results of our investigation indicate an OWS can be installed at` he location presented on Figure 1. The OWS design is based on an average daily sewage load of 1800 GPD with an advanced treatment system and a drip -irrigation drain field. The advanced treatment installation includes two 2000 -gallon (total 4000 gallons), one -compartment concrete septic tanks, with an AdvanTexTm AX20 Treatment System, as presented on Figure 2. Discharge is via a 500 -gallon tank with a pump vault unit (PVU) with dual pumps, as presented on Figures 2 and 4. Pump specifications are included as Figure 3. Similar to a recirculating sand filter, the AdvanTexTM system provides treatment of organics, (total suspended solids and BODS) and nitrate reduction using effluent recirculation through a textile media -filled pods. The AdvanTexTm units treat the effluent before being discharged to the drain field by a dosing -pump. A service contract is recommended for operation and maintenance of the advanced treatment system. W460 OWS 2 Design Job No. 13288 Page 3 Our design includes the installation of 6480 square feet of drip -irrigation field. The drain field installation should include 6480 SF of drip -irrigation field in 6 sections as presented on Figures 1 and 6. The drip irrigation field configuration can be modified to fit the topography with approval of our office. The trenches should be backfilled to re-establish the original slope. The installation is presented with a trencher. The surface of the drip irrigation or ETA field should be seeded after installation of the system. A native seed mix available at seed stores should be used. These mixes do not require irrigation and develop a growth 10 to 15 inches high. No automatic sprinkler system should be installed over the field. INSTALLATION OBSERVATIONS The installation of the OWS is to be observed by the design engineer. We will verify field depth, separation distances and subsurface conditions. The septic tank and AdvanTex1m units are to be installed with risers on the tank, and inlet and outlet connections properly bedded. Other components such as effluent filters or pumping systems, as applicable, will be observed at that time. OPERATION AND MAINTENANCE The AdvanTexTM treatment system is sold as a package that includes component installation and two years of operation and maintenance. We recommend an operation and maintenance contract exist at all times with a certified AdvanTexTM maintenance company. During the first month of operation, the system is to be observed to ensure proper control settings and system "start up". Subsequent to system "start up" a semi-annual observation is to be performed. During the semi-annual observations, septic tank sludge and scum accumulation is to be measured and septage pumping arranged as necessary. The treatment system components are to be cleaned in accordance with the manufacturer's recommendations. Effluent quality is to be observed to confirm a clear, odorless effluent is discharged to the drain field. The dosing system is to be observed to verify its operation. The surface area over the drain field is to be observed for indications of effluent surfacing. Liquid levels in the field are to be measured and recorded. The owner must realize an OWS is different from public sewer service. The owner must be aware of, and assume responsibility for, ongoing maintenance of the system. In the absence of a monitoring program, the septic tank should be pumped every two years. Effluent filter and screened vaults, as applicable, are to be cleaned during pumping. There are daily considerations such as not putting plastic or other nonbiodegradable materials into the septic system. Garbage disposal use should be minimized to reduce the frequency of pumping. Water use must be monitored so toilets are not allowed to run when seals malfunction. To illustrate the point, a flowing toilet can use in excess of 1000 GPD. An additional 1000 GPD loading may flood and irreparably harm the system. We caution against the installation of a water softener. The hydraulic loading from the backwash of a water softener is detrimental to an OWS and a separate drywell should be constructed for the backwash waste, if a softener is installed. No landscaping or plastic can be used over the field, which will reduce performance of the field. Chemically treated water from a swimming pool or spas should not be introduced to the OWS. The design of the OWS is based on the treatment of domestic sewage only. No industrial or hazardous wastes should be introduced into the OWS. Floor drains should not discharge into the OWS. OWS 2 Design Job No. 13288 Page 4 As a part of the experimental permit, there are conditions imposed by the APEHD. The differences from other installations are the requirements for monitoring of the installation of the drip -irrigation system. These may be required because of a prior experience in Pitkin County with experimental systems. Drip -irrigation systems have been installed in Pitkin County and there have been no problems. We anticipate the annual reporting will be a requirement for five years and the cost is estimated to be $200.00 per year if the experimental status is required. LIMITATIONS Our investigation, layout, design, and recommendations are based on data submitted. If conditions dif- ferent from those described in this report are encountered, we should be called to observe the conditions. If proposed constriction is changed, we should be notified to evaluate the effect of the changes on the wastewater system. All construction is to be in accordance with the ISDS regulations. Pipe type and size, burial requirements, septic tank construction, and other specifications, which are not depicted in our report, are to conform to the requirements of the ISDS regulations. The installer of the system is to be by an experience installed and is to have demonstrated knowledge of the ISDS regulations and requirements. If there are questions or if we can be of further service, please call. The project manager is Tim Petz. Sincerely, CHU Edw, EOC/trp 5 copies sent by FED EX Copy to Pitkin County Community Development, ATTN: Suzanne Wolf 130 South Galena Aspen, CO 81611 Copy to Fenton Construction, ATTN: Holly Hamilton 117 South Monarch Aspen, CO 81611 TWO MILE RANCH, OWS #2 S23, T9S, R85W PITKIN COUNTY, COLORADO i a 1 goo `► J"' NO. 13288 .1 RICULTI BARN msnf4c Swo .— I '� i 212' ETB �K FROM XISTING $ CREE OLE BARN ;� BODY `CREEK . UTI�C.ORRIDOR' UNDER ROAD`----�_�' HDPE SEWER LINE -� (S fii-40 UNDER MUM Q 6 )12' X r ' SE ICN�1S� IF�RIGA El�� Fk7R 480,% 0 I ILd RAT WE ITE PLAN, LOCATION OF `\ PERCOLATION HOLES, AND LOCATION OF PROPOSE[] OWS No' �' lliiLiil' CORRID ONDER ROA j T 0 20b0 -GALLON, SING, PART NT, P ECAST CONCRETE SEPTIC TANKS 0,5 C NNECTE' MID -TANK WITH DUAL EN A TERNATI PUMPS, ONE FOUR OUTLET', A TOMATIDG ISTRIBUT(NG VALVE,ND r VANTEX, TREATMENT SYS LO BY 0 - STATION PVU W DU L ALTERNATING PU PS TO DRIB' FIEL ry i -,\ N WOODY GEEK :6 ACREI BUILDING .w F lit Still} t{i ill SCALE "= 100' N-3 2A4 cm -mm T.E.^-..M A 5!.^..24 Bt .Fi AND r -V 10/01/01 FIGURE 1 AdvanTexTM- AX20 System for Qp, = 4,000 gpd General Notes Residential Strength Wastewater HOD: 200 mg/L Grease & Oil: 20 mg/L • Qpa= 4,000 gpd • Q. = 2,0}0 gpd TWO 2000 -GALLON, SINGLE -COMPARTMENT, PRECAST CONCRETE RECIRCULATION TANKS AND ONE 500 -GALLON LIFT STATION JOB N0. 13288 ,m Line 10/01/01 FIGURE 2 Ri I .•'`� m Tt|aDynamic Head 7DH,feet J ■� @ 0 Cr 2 k 0 CO N E � c 2 � � (D 6 n 0 � 4 � z 0 � "0 2 CO) @ c N CD CL CO) � @ � 6-1 30 0C) .- .. \ / a o 7� \ ) / ■ ■ n I A CLCDk = r o a I § w E C 7 E \ \ \ \ _ ; 7 3 § o n 6 k ® # a Q -n» § \ /\o§k z (D 2 I M \ & § \ § M ƒ %% o k \ / \ \ \ 2 Tt|aDynamic Head 7DH,feet J ■� @ 0 Cr 2 k 0 CO N E � c 2 � � (D 6 n 0 � 4 � z 0 � "0 2 CO) @ c N CD CL CO) � @ � 6-1 30 0C) .- .. \ / a o 7� \ ) / ■ ■ C_ o o 0 O1 co ^^Z y l J Q " co -P CA3 rt -p.- C,3 p.-to CA _CO CO W N 9: W to F' coco N O) w T C O � O mo --, CD C CD CD 00) CD cr CD �ir+i=C: 4rA CA a O n CDCD CD :q coCDl f - C1 o n a c Own 3 a m m o rn CA En rt O rn o f Oy CD C3.�rr — � S O C-0 S a C1.i O_ CD O co O o CD m � o C x ff' cu v o :3 CD t0 O = CD In fAm S NCA O co CO vrn y�y to �' Z m cc cr O O M CD �Q CD 0 3 CD �F CA .--F O Cl) a CD C/3 Q] n 40 fn Cp � • I ren a o z N f!i m m Z m 3 N a CD c O m rt F 0 O d = < ® C tD M C d rt -moi _0 CD D CO O C _ O a A. ^ p "O O C r+ =3 0 co O o CD m � o C x ff' cu v o :3 CD t0 O = CD In fAm S NCA O co CO vrn y�y to �' Z m cc cr O O M CD �Q CD 0 3 CD �F CA .--F O Cl) a CD C/3 Q] n 40 fn Cp � • I ren a o z N f!i m m Z m 3 N a PRO -1: 0� m FIGURE 5 - PERCOLATION TEST RESULTS Two Mile Ranch DATE OF TEST: 9/26/01 S23,T9S,R85W Pitkin County, Colorado •r- 0 - 1 ITopsoil, root zone, dark brown 1 - 9 Silty clayey sand, dense, moist, brown/red, angular rock fragments NO GROUNDWATER WAS ENCOUNTERED WITHIN EXCAVATION 1 38 20 3.50 AVG. DEPTH INTERVAL TIME DEPTH DEPTH HOLE HOLE OF CHANGE, PERC. INTERVAL, START, END, pERC. NUMBER HOLE, (INCHES) RATE (MINUTES) (INCHES) (INCHES) RATE, (INCHES) (MPI) IMPI► 1 38 20 3.50 6.50 3.00 7 20 2.25 4.50 2.25 9 20 4.50 6.50 2.00 10 20 2.50 5.25 2.75 7 20 5.25 6.25 1.00 20 20 6.25 7.25 1.00 20 20 2 26 20 3.25 7.50 4.25 5 20 2.00 5.50 3.50 6 20 2.75 4.75 2.00 10 20 2.75 4.75 2.00 10 20 1.75 4.00 2.25 9 20 4.00 6.00 2.00 10 10 3 35 20 3.00 8.50 5.50 4 20 2.50 5.50 3.00 7 20 5.50 7.75 2.25 9 20 1.75 4.25 2.50 8 20 4.25 6.25 2.00 10 20 6.25 8.00 1.75 1 11 1 11 JOB NO. 13288 PRO - 1: FIGURE 5 (CONT) PERCOLATION TEST RESULTS Two Mile Ranch DATE OF TEST: 9/26/01 S23,T9S,R85W Pitkin County, Colorado 0 - 1 Topsoil, root zone, dark brown 1 - 9 Silty clayey sand, dense, moist, brown/red, angular rock fragments NO GROUNDWATER WAS ENCOUNTERED WITHIN EXCAVATION 4 27 20 1.50 AVG. DEPTH INTERVAL TIME DEPTH DEPTH CHANGE, PERC. HOLE HOLE 'OF NUMBER HOLE, INTERVAL, START, END, (INCHES) RATE PERC. RATE, (INCHES) (MINUTES) (INCHES) (INCHES) (MPI) (MPtl 4 27 20 1.50 3.25 1.75 11 20 1.00 2.50 1.50 13 20 2.50 3.50 1.00 20 20 1.50 2.25 0.75 27 20 2.25 3.00 0.75 27 20 3.00 3.75 0.75 27 27 JOB NO. 13288 TYPICAL PLAN VIEW EFFLUENT PUMP LINE WITH PRESSURE RELEASE VAI 1/C AT LJI/YU O/VAIT DISTRIBUTIC VALVE 2" BALL VALVE HEADER LEVE MANIFOL NO. LENGTH WIDTH LINES 6 90 12 6 TYPICAL FIELD CROSS-SECTION 90' ' PVC .NT PIPE IG 2" HDPE 10'; IRRIGATION VENT PIPE SPECIFICATIONS AND DESIGN CALCULATIONS TREATMENT NIT 1. TWO 2000 -GALLON, SINGLE -COMPARTMENT, PRECAST CONCRETE SEPTIC TANKS WITH ADVANTEX - TREATMENT SYSTEM FOLLOWED BY ONE 500 -GALLON LIFT STATION PVU WITH DUAL ALTERNATING PUMPS J' 2. PUMP: SEE DETAIL 3. ALARM/CONTROL PANEL LOCATION AT OWNER'S REQUEST 4. PRESSURE RELEASE: VALVE AT HIGH POINT 5. DRAINBACK TO LIFT STATION AND FIELD DISTRIBUTION FIELD JRFACE 'PERSAL JE 1. OWS: SEE TABLE 1 OF REPORT,/ 2. SEWAGE LOADING = Q = 3150 GPD 3. PERCOLATION RATE = 17 MPI '/ 4. APPLICATION RATE = R = 0.50 GAL/SF/DAY 5. AREA = (Q/R) = 6300 SF 6. PROPOSED FIELD AREA = 6480 SF 7. LINEAL FEET = 3240 8. TRENCH WIDTH = 8 INCHES 9. LANDSCAPING IS THE RESPONSIBILITY OF THE OWNER 10/01/01 JOB NO. 13288W TRENCH DETAILS FIGURE 6 is tiNDEM ON C'ONGEB orchitecture 8e planning P. 0. Box 178 3448 Woody Creek RD. Woody Crede, CO 81656 tel 970.922.0151 fax 970.922.0151 YEARY RESIDENCE 2 MILE RANCH WOODY CREEK, COLORADO FILE:A3.1 DATE: 08/29/2001 DRAWN BY: BK CHECKED BY: EA ISSUE: PERMIT SET DOCUMENTS REVISIONS: 07-31-01 09-12-01 MAIN LEVEL FLOOR PLAN SCALE: 1/4'•1'4Y A3.1 o 2001 APCMRECf$ J ANDERSON CONG EM architecture Sc planning P. 0. Box 178 3448 Woody Creek RD. Woody peek, CO 81656 tel 970.922.0151 fax 970.922.0151 YEARY RESIDENCE 2 MILE RANCH WOODY CREEK, COLORADO FILE:A3.2 DRAWN BY: BK CHECKED BY: EA ISSUE: PERMIT SET DOCUMENTS REVISIONS: 07-31-01 09-12-01 UPPER LEVEL FLOOR PLAN SCALE: 1/4'•1'0' A3.2 ® O pot hoof m CIRCLE R RANCH Onsite Wastewater Systems: OWS # 1 OWS # 2 OWS # 3 OWS # 4 OWS # 5 OWS # 6 2643-234-01-001 Historic House 0185 Circle R Road Historic Garage 0169 Circle R Road Agricultural Barn 0195 Circle R Road 0 Granary 0155 Circle R Road 0 Pump House 0181 Circle R Road Old Toll House 2643-243-01-002 Natal Cabin 0061 Circle R Road Electrical Station for Subdivision 0245 Circle R Road Yeary Residence 0264 Circle R Road Elliot Residence 0265 Circle R Road Water Tank 0260 Circle R Road Building Envelope # 5 Old Log Structure by Bridge 2643-244-01-003 Water Treatment # 2 4301 Woody Creek Road Acton Residense 4305 Woody Creek Road Building Envelope # 7 4415 Woody Creek Road Building Envelope # 8 2643-244-01-004 Water Tank 4801 Woody Creek Road Graham/Wyly Residence 4811 Woody Creek Road Water Treatment # 3 4815 Woody Creek Road Matthew Residence 4819 Woody Creek Road Underground Water Storage Tank