Loading...
HomeMy WebLinkAboutpitkin.eh.264326103002 (2000)Permit # 80008 11 F7 Aspen/Pitkin Environmental Health Department Permit for an Individual Sewage Disposal System 130 S. Galena St. Aspen, Colorado 81611 Phone 970-920-5070 / FAX 970-920-5074 Parcel ID # 2643-261-03-001 Type of permit New( ) Repair( ) Addition to House( X) REMODEL Name of Owner Carroll Drive Properties, LLC (William Ziff) Street Address 1020 Carroll Drive Property legal description Lot R86A, Blk 15, Starwood Size of lot 24 acres Total square footage of the house 10,340 Water source Starwood Water District # of bedrooms in house 4 # of offices, lofts & similar sized rooms in house Caretaker unit -- # of bedrooms in caretakE!r unit Designed for what # rooms (list) Designed by Mailing Address Perc rate 54 Septic tank capacity SGM Total square footage of the caretaker unit -- # of offices, lofts & similar sized rooms in caretaker unit -- FOUR (3 bedrooms, 1 bedroom/library) Permit information 118 W. 6th Street, Suite 200, Glenwood Springs, CO 81601 Profile hole depth +8 Depth to groundwater or bedrock +8 2500 min, 3500 per design Absorption area 2476 minimum, 4480 per design Comments Septic permit approved per compliance with the engineer design and specifications dated and stamped 02/28/00. Any changes must be approved by this department and the design engineer prior to them being made. Minimum horizontal distances between components of the system and physical features shall conform to the Pitkin County ISDS regulations. A septic tank capacity of 3500 gallons is required by the engineer. The 1 st tank should be 2,000 gallon and unbaffled. The 2nd tank should be 1500 gallon and also unbaffled. The design is for an ETA disposal area of 4480sf ft of effective area-- two 20 ft by 112 ft beds using a total of 144 infiltrator units. Surface mounding of each bed and drainage away, from the beds is required. The engineer must do a final inspection of the installation and submit an as -built letter to this department. This department must also be called for an inspection with a minimum of 48 hours advanced notice. Permit approved by: z Date: 3 — 9--DCD Plans and specifications of the pr osed individual sewage disposal system have been reviewed and are considered satisfactory. Permission is hereby granted to the owner or the agent to perform the work indicated in accordance with the Pitkin County ISDS Regulation in effect at the time of issue. This permit becomes invalid 6 months from the date that the permit was issued unless system construction has commenced or an extension has been approved in writing by the Department. As -built drawings must be included with this permit before the final approval will be issued. Installer: Final inspectionapproval: t r Date: ✓ Cr L0 ASPENR ITKIN ENVIRONMENTAL HEALTH DtPARTMENT APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM 130 S. Galena St., Aspen Colorado 81611 Phone 970-920-5070/Fax 970-920-5074 Name of OWNER C� (r -o `� f Owner's Mailing Address �J C� �'`�'� 0-:s eLn CU ( 1 Business Phone: Home Phone: Z-5 3 % Primary Contact Person (all communication regarding this permit will go through this person) Name �t�G� Company G Contact Mailing Address Business Phone ZO -t Z 7 Cell Phone : 3% "�/ �%G �� Fax: 2 Z y Parcel ID # (available from assessor's office at 920-5160 or at www.aspen.com/assessor/) Street address of property Legal Description: Lot p`'AA ,Block /15� -::�— �— �L ---2> - -)- �— L - -L a- - -a d -� C 0.ry-b v\ q �nz ,Filing Subdivision S ,rV-s`,Ja Size of lot: 22Lt 'r acres. Type of proposed structure: S,` S e of bldg. envelope: Total square feet of house ) 3 qO # of bedrooms in house # of offices, lofts & similar sized rooms in house Caretaker Unit: Attached ('Z% Detached (�� Total area(sq. ft.) of caretaker unit # of harirnnms in caretaker unit # of offices, lofts and similar size rooms of caretaker unit Permit is for: New Home ( ) Repair due to failure ( ) Remodel/Addition) Emergency use ( ) Water: Private well (x) Spring ( ) Stream(( ) Community/Publi Water System ( ) If community system: Name of system 5�, D�' I I The fee for a ISDS application is $330 for a permit that takes 6 hours or less for the department to approve. If approval takes longer than 6 hours, a rate of $55 per hour will be charged. The maximum fee is $1000. The basic fee of $330 is due at the time of application. The remainder, if any, will be due in two stages: first, at the time of issuance of the ISDS permit; second, before final approval of the ISDS permit. Application for an individual sewage disposal system is hereby submitted. I hereby certify that the above information is true and accurate and that I have provided true and accurate information on locations of all existing and proposed wells, contour intervals, buildings, property lines, ditches, slopes, waterlines, springs, suction or irrigation lines, drinking water cisterns, drain tiles, irrigation ditches, lakes, water courses, streams, floodplains, dry gulches, and existing septic systems. I hereby certify that any such features riot shown on attached site map are not present. Issuance of the permit does not imply the approval of any other permit required for construction pursuant to Pitkin County codes. No construction may be undertaken until all approvals and permits have been obtained. The Aspen/Pitkin Environmental Health Department, Pitkin County and employees of these agencies will be held harmless should the individual sewage disposal system fail or malfunction. The permit to construct is issued on information submitted by the applicant or his/her representatives. The owner assumes full responsibility in case of failure of the system. Signature of applicant Date Received by Receipt # ) 1 o ;� Date z z 0 0 ty G:\eh\isds\isdsapp.doc Aspen / Pitkin Environmental Health Dep hent Contact Log Sheet Address: Date , Person Spoken To Comments Action to be Taken I Initials ITime MENWOM w A=Oil 011 �15ll�R SCHMUESER GORDON I MEYER ENGINEERS & SURVEYORS January 31, 2003 Nancy MacKenzie Pitkin County Environmental Health Dept. 130 South Galena Aspen CO 81611 RE: Ziff Residence ISDS Dear Nancy: GLENWOOD SPRINGS LAiCRESTED BUTTE 1 18 W. 6TH, SUITE 200 P.O. BOX 2 1 55 P.O. BOX 3088 GLENWOOD SPRINGS, CO 81601 ASPEN, CO 61612 CRESTED BUTTE, CO 81 224 970-945-1004 970-925-6727 970-349-5355 FX: 970-945-5948 FX: 970-925-4157 FX: 970-349-5358 RR,EIVE® FEB 3 2003 PITKIN COUNTY ENVIRONN$ENTAL HEALTH The purpose of this letter is to provide you with documentation of the construction observation performed for the Ziff ISDS in Starwood (Parcel #2643-261-03-001). During the months of October and November 2001, 1 observed the construction of the septic system at the critical points. First of all, the removal of the existing system and preparation of the subgrade for the new system was observed and deemed to be acceptable. Secondly, the import of sand material and installation of infiltrator units and distribution piping was observed. You and I actually met on site to discuss and revise the configuration of the distribution header. This revision was completed and the lower bed distribution manifold was constructed in the same acceptable manner. Finally, the installation of the septic tanks and gravity feed line from the house to the bed was observed. Based upon these observations, the installation of the septic system was completed as per the approved construction documents prepared by SGM. I am also including a record drawing of the system. The installer, Earthworks Construction, provided the distances shown on the drawing. Please do not hesitate to call, should you have any questions regarding this matter. SCHMUESER GOC - - Dan Cokley, P.E. DC:lc/9008D-05 cc: Rocky Tschappat, 1020 Carroll Drive, Aspen, CO 81611 Don Herman, Hansen Construction Sean Mello, Earth Works Construction 40111111111111111111111 AUG.19.1997 9:39AM STARWOODHOME OWNERS 4 STARWOOD WATER DISTRICT 0121 Stewart Drive Aspen, Colorado 81611 T0: Environmental Health Department FROM: Julia Johnston, Secretary Starwood Water District DATE: August 19, 1997 'E' Water Service This is to confirm that the Starwood Water District will supply water to the residence on Tract R -86A, Starwood Subdivision, owned by William Ziff. If you have any questions. please call me at 925-8939. "''I THU 12:14 P ZIFF ASPIEN'OFFI(JE 0 FAX NO, 9709201228 P, I ate: Be,— CC: ocky Tschappat 0 Urgent 0 For Review � Please Comment crnrnents: rim S-�e 0--) pry W i'.I.TG-21:97 THU 12:14 PIS Z I FF ASPEN OFFICE FAX NO. 9709201228 P. 2 ® 0 9 7 THU 12:15 PM Z IFF ASPEN OFFICE . FAX N0, 9770094201228 P. 3 AU" -21, 0 v AUG-.21�- 97 THU 12 : 15 ZIFF ASPEN OFFICE FAX NO, 9709201228 P. 5 ,AUG;21-97 THU 12 15 P ZIFF ASPEN OFFICE FAX N0, 9709201228 P. 4 • 0 11/28/95 08:51 10303 945 5948 0 S G X INC U004 r� 11128,95 08:50 $303 945 5948 S G M INC g&on Em*w:menka & KasftwaUr &2b&O% .Ltd �. w �A •/, Zi 1iry������� paddim Lot 1t-$1 and 52, Stm-"OdSubO&icm - CM011 Drive 5 34 20 noLe LeWb Depth $t beef at Dmp in Average Hole Depth oflnerval Start of I11twad Etxi of Interval Rater Uvel Peroda Ion NO. {in) i �} �iu�-tze�) �L�chcs} (7u�i�es� iratt�Mtn.tlnoh) 1 31 20 1I 105/16 11116 15 105116 9718 7/16 15 9718 97116 7/16 10 97/16 91/4 3/16 10 9 114 91116 3116 53 2 34 20 8112 7319 1 118 15 7 3M 611/I6 11116 15 611116 6118 9/16 10 6 118 5.718 1.14 10 5719 5 518 I/4 40 3 31 20 311116 1718 113116 is 17/9 1 718 (00) 10 6 51122 1/2 Its 51/2 51116 7116 IO 51/16 4 314 $/16 32 4 33 20 71/2 63/4 3/4 20 6 314 57/8 718 10 57/8 5518 114 10 55/8 $7116 3116 10 57116 55116 118 (80) 5 34 20 6 518 4112 21/8 20 4112 3 11/2 20 3 2 1 (I -CM 10 6 114 57/9 318 10 $ 7/8 59/16 5116 I 32 P.O.18ox6961 SnOVOnaw Vf31age, CO 81615 Office (309) M -32M Homt (30) 92Z• 2766 IR 002 rr�llrrr 11!28/95 08:51 X303 945 5948 S G N INC j005 TABLE i MM IKSX Maw. MOM 719 R =. ]Goat 11-51 and %% Starwood Subdivisic a - Carroll Dive Hole L,e agtli Depth it Depth at Drop in ,Average Hole Depth o£IntervaS Stat of lntemv End of serval tater Level Percolation No. {n,.) r(Mmites) (inres) (icci+e) (Ii) Rate(Min./tnch) 6 30 20 135/9 13 114 318 20 13 114 127/9 3/8 10 12719 1211/16 3/16 10 1211/16 129/16 1/8 to 129116 127116 318 So. 7 31 20 g 67/8 1 118 20 6 718 415/16 15/16 10 415116 49116 7/16 10 49116 4 114 5116 10 4 114 4 114 40 $ 31 20 7 314 6 7/8 718 20 6 718 6115 314 10 61/5 511.116 7/16 10 5 11116 5 319 5/16 _ 10 53/8 5 118 114 40 2 �� r111■rw _11%28%95 08:48 _ ' 30� 945 5948 S G M INC Nebew EnvirqnnwnW & Was iter S'obat>r+tom F Property Address_ Cart 11--.f)fiYQ W W. Legal Descriptton. A Tract vO i in the Starwood Sutdyision - R-61 artd.R-52. Property Owner Nanta W-2 am Zif f Contractor_ Excavating Coniractar Dame ,stocky Tschaeo$t dame Barth Works QorrgMLgtion AdOress P_ 0. L'AM 7947 AddresMerrill_ Ave. rtsrt.g`s CariaondNe. GO 81623 PhOr* 32 654 Phone Ub"U a and Svc a Smemed sainMremmmed x Yrs o Gawe1 Added Yes To a 3' Depth o and Time prM9k water sskiz# 0 AMD= ttpreeoak w= added ApMM&MdCW 20 Pos !hate ( lit pUm tier dU bdbre ft Wd Md 10 Mfioas Me +dMy afthe MR) o Waw =u&ftg ita Mm after PMSU40 I:e 1 x 'KGs 2I H�i+e a x 'Yes No Hote --X-Yes No time 4 X Yes N BgB 5 Yes _XNo H&C 6 X Ys* Na HDle 7 . , X Yes NQ Hae 7 —XI -Its No P'ctCalslioa ELM Mem Role I. SS rcizt Hdc Z- - 40 minal=FU h Ode 3: 32, min ht S* 4: so tnimstz M* Hole 5: 32 UambWinch Hole 6: so aninutwiroch Hok 7; 40 raiaWee MOM Hold 8: 40 mimuteSrUXh ME AGE 50 Proffle trot yet dom. lit vq=fed to be similar to ono done prrviousty is the ate., 50 ftaway GranndW*tV V - o Ea m ied d*h to bigh seaw W -saw o Is a= bdkved to be stAi= w resort � asoma£ water table? . _ Yes x No Slow is a#ynptptioa arft 15% to fire West SedM& o E cid depth if riot ester 3n ft. o Type ofbedro&- Sas&ww :� ckw=rlo Silts OM CXher X =Wrcd Weathemd o Fs bWrock belicycd to be pcxsrse N4P, Yes No I car* that the above infomtatian is COMd and complete to the best of my knowledge and that all tests were pedorrnetd in ac=rdance %ith the provisions of the pWn County Code Tide X. Mole 5.1 through 5.7.(Pitkin CouA Regulation Individul Di i 11� RcAwd. F_ Nelson Prtnt Reviewed by: Dari C;okiey, PS Schmueser, Gordon Meyer, p.o. BOX6M Svowm 8 VMW, CO. 81615 Of ftce (303) 923.3289 Home (30 3) 923 A 2766 It 1 HEPwORTH-PAIVLAK GEOTECHNICAL, INC. August 14, 1997 C 5020 load 15-' Gienwood Springs, CO 51601 Fax 970 945-8454 Phone 970 945-7988 Ziff Ranch Attn: Randy Tschappett 1020 Carroll Drive Aspen, Colorado 81611 Job No. 197 228 Subject: Supplemental Subsurface Study for Foundation Support, Proposed Ziff Residence, Ziff Ranch, Pitkin County, Colorado Dear Mr. Tschappett: As requested, Hepworth-Pawlak Geotechnical, Inc. performed a supplemental subsurface study for design of foundations at the subject site. The project site is shown on Fig. 1. The study was conducted in accordance with our agreement for geotechnical engineering services to Ziff Ranch, dated July 8, 1997. A previous subsurface study was performed by Chen -Northern Inc., under their Job No. 4-177-93, dated January 4, 1993 for originally proposed additions to the existing residence. Scope of Work: A field exploration program consisting of exploratory borings was conducted to obtain information on subsurface conditions. Samples of the subsoils and bedrock obtained during the field exploration were tested in the laboratory to determine their classification, compressibility or swell and other engineering characteristics. The results of the field exploration and laboratory testing were analyzed to develop recommendations for foundation types, depths and allowable pressures for the proposed building foundation. This report summarizes the data obtained during this study and presents our conclusions, recommendations and other geotechnical engineering considerations based on'the proposed construction and the subsurface conditions encountered. Proposed Construction: The proposed residence will be a 2 to 3 story structure with steel frame mostly over crawlspace. The floors will be concrete slab supported by a structural metal deck. Crawlspace grade is proposed to be 8,717 feet. There will be a lower level for mechanical equipment with slab -on -grade floor. The building Ziff Ranch August 14, 1997 Page 2 excavation will be up to about 28 feet below the existing ground surface. For the purpose of our analysis, foundation loadings for the structure were assumed to be light to moderate and typical of the proposed type of construction. If building loadings, location or grading plans are significantly different from those described above, we should be notified to reevaluate the recommendations contained in this report. The existing residence is supported by drilled piers which are reportedly about 2 feet in diameter and 16 feet apart. The existing residence will be mostly razed for the new construction. Previous Subsurface Study: The previous study performed by Chen -Northern, Inc. included 4 borings which encountered 4 to 5 feet of clay overlying weathered to hard claystone bedrock down to 38 feet. Only 2 of the borings were close to the proposed building footprint. The Chen -Northern report recommended drilled piers for support of the residence. Field Exploration: The field exploration for the current project was conducted on July 21, 1997. Two exploratory borings were drilled at the locations shown on Fig. 1 to evaluate the subsurface conditions. The borings were advanced with 4 inch diameter continuous flight auger powered by a truck -mounted Longyear BK-51HD drill rig. The borings were logged by -a representative of Hepworth-Pawlak Geotechnical, Inc. Samples of the subsoils were taken with a 2 inch I.D. spoon sampler. The sampler was driven into the subsoils and bedrock at various depth with blows from a 140 pound hammer falling 30 inches. This test is similar to the standard penetration test described by ASTM Method D-1586. The penetration resistance values are an indication of the H -P GEOTECH Y Ziff Ranch August 14, 1997 Page 3 relative density or consistency of the subsoils and hardness of the bedrock. Depths at which the samples were taken and the penetration resistance values are shown on the Logs of Exploratory Borings, Fig. 2. The samples were returned to our laboratory for review by the project engineer and testing. Subsurface Conditions: Graphic logs of the subsurface profiles encountered at the site are shown on Fig. 2. Below about 1 to 5 feet of organic topsoil or clay fill, the subsoils consist of 3 to 10 feet of stiff to very stiff sandy clay with shale fragments. At depths of about 4 to 15 feet of hard to very hard claystone bedrock was encountered to the maximum depth explored of 41 feet. The soils and bedrock encountered in the borings are similar to the those described in the Chen -Northern study. The clay and claystone bedrock generally possess an expansion potential when wetted. Groundwater was not encountered at the time of drilling but had developed in Boring 1 at a depth of 30.5 feet when measured 2 days later. The subsoils and bedrock were generally slightly moist to moist. Laboratory testing performed on samples obtained during the field exploration included natural moisture content and density, percent finer than sand size gradation analyses and liquid and plastic limits. Swell -consolidation testing was performed on relatively undisturbed drive samples of the clay subsoils and claystone bedrock. In general, the swell -consolidation test results, presented on Figs. 4, 5 and 6, indicate low compressibility under relatively light surcharge loading and a low expansion potential when wetted under a constant light surcharge. The test results of a claystone sample from Boring 2 indicate a relatively high expansion potential with 3.5 % expansion upon wetting and a swell pressure of about 15,000 psf. The clay and claystone materials are generally medium plastic. The laboratory testing is summarized in Table I. H -P GEOTECH t Ziff Ranch August 14, 1997 Page 4 Foundation Bearing Conditions: The clay soils and claystone bedrock encountered at the site generally have low expansion potential but the bedrock contains layers of moderatly to highly expansive claystone. Due to the variable bedding, the depths and extent of the more expansive claystone can not be predicted. Therefore, we recommend that the residence be supported with a drilled pier foundation. The recommendations contained in the Chen -Northern report can be used for design of the drilled pier foundation (items 1-12, attached). In addition, we recommend the following: 13) Piers located closer than 3 diameters center to center may have reduced capacity and should be analyzed on an individual basis. 14) The existing piers should not be used to support the new foundation due to their unknown depth. 15) New piers should not be installed closer than 2 feet to existing piers. The existing piers should be cut off at least 4 inches below bottom of the grade beam to allow for the void form. Disturbance of the ground due to the demolition of the existing structure should be evaluated during the pier construction and the need for additional pier depth. 16) Bedrock encountered within 3 pier diameters of the cut grade should be neglected in the skin friction capacity. Limitations: This study has been conducted in accordance with generally accepted geotechnical engineering principles and practices in this area at this time. We make no warranty either expressed or implied. The conclusions and recommendations submitted in this report are based upon the data obtained from the exploratory borings drilled at the locations indicated on Fig. 1, the previous Chen -Northern report, the proposed type of construction and our experience in the area. Our findings include interpolation and extrapolation of the subsurface conditions identified at the exploratory borings and H -P GEOTECH Ziff Ranch August 14, 1997 Page 5 variations in the subsurface conditions may not become evident until excavation is performed. If conditions encountered during construction appear to be different from those described in this report, we should be notified at once so reevaluation of the recommendations may be made. This report has been prepared for the exclusive use by our client for design purposes. We are not responsible for technical interpretations by others of our information. As the project evolves, we should provide continued consultation and field services during construction to review and monitor the implementation of our recommendations, and to verify that the recommendations have been appropriately interpreted. Significant design changes may require additional analysis or modifications of the recommendations presented herein. We recommend on-site observation of excavations and pier drilling, and testing of structural fill by a representative of the geotechnical engineer. Sincerely, HEPWORTH - PAWLAK GEOTECHNICAL INC. Daniel E. Hardin, P.E. Reviewed By: Steven L. Pawlak, P. DEH/kw/ro �_'� ¢yam • F'; •a 15222 s• cc: Ike & Kligerman - Attn: Marcial Chao Robert Silman Associates - Attn: Nat Oppenheiner H -P GEOTECH Ht'KQ' 95 12:03 No . 003 P.12 -g_ 1) The piers should be designed for a maximum (allowable) end bearing pressure of 25,000 psf and an allowable skin friction of 2,500 psf for that portion of the pier in claystone. 2) Piers should also be. designed for a ntinimurn dead load pressure of 10,000 psf based on pier end area only. 3) Uplift on the piers from structural loading can be resisted by utilizing '15% of the allowable skin friction value plus an allowance for the weight of the pier; 4) Piers should penetrate at least three pier diameters into the bedrock. A minimum C penetration of 10 feet into the bedrock and a minimum pier length of 20 fcct are recommended. 5) Piers should be designed to resist lateral loads assuming a modulus of horizontal suhgrade reaction in the clay soils of 10 tef and a modulus of horizontal subgrade reaction in the weathered bedrock of 50 tef. The modulus values given are for a long, 1 -foot wide pier and trust be corrected for pier size. 6) Piers should be reinforced their full length with one #5 reinforcing rod for each 16 inches of pier perimeter to resist tension eroated by the swelling materials. 7) A 4 -inch void forth should be provided beneath grade beams to 1)revcnt the swelling soil and rock from exerting uplift forces on the grade beams and to concentrate pier loadings. A void form should also be provided beneath pier caps. 8) Cbncrete utilized in the Piers should be a fluid mix with sufficient slump so that concrete will fill the void between the roinforcing steel and the pier hole. Chen Northern, nc. Z mid f:�r�y.vo�p fnp��rr.�sawll:rx:ro6ts T8EbLb6ZTZ 8b:9T 9661/GZ/90 . •; • .••, L,.rvv� ' �uJ—yLV^JQ�u Ht' or, • 95 12:04 No .003 R.13 .9- 9) Pier holes should be properly cleaned prior to the placement of concrete. The drilling contractor should mobilize equipment of sufficient size to effectively drill through possible coarse soils and cemented bedrock zones. 10) Although no water was encountered in the borings drilled at the site, some Qeepago in the pier holes may be encountered during drilling. Dewatering equipment may bo required to reduce water infiltration in the pier holes. If water cannot be removed prior to placement of concrete, the tremic method should be used after the hole has been adequately cleaned. In no case should adncrete be placed in more than 3 inches of water cxcept by the tremie method. 11) Care should be taken to prevent the forming of mushroom-shapW tops of the piers which can increase uplift force on the piers from swelling sails. 12) A mepresentadve of the soil engineer should observe pier drilling operations on a full-time basis. FOUNDATION AND RFI'AINING WALLS Foundation walls and retaining structures which arc latemily supported and can be expected to undergo only a slight amount of deflection should be designed for a lateral earth pressure computed on the basis of an equivalent fluid unit weight of 60 pef for backfill consisting of the on-site fano grained soils. Cantilevered retaining structures which are separate from the residence and can bd expected to deflect sufficiently to mobilize the full active earth pressure condition should be designed for a lateral earth pressure computed on the basis of an equivalent fluid unit weight of SO pef for backfill consisting of the on-site fine-grained soils. C.'hen @Northern, I m Conkia og EMS+ Z owj'.1wom.QL 61 3DVd 18E17L176ZTZ 817:91 9661/8Z/90 APPROXIMATE SCALE 1" = 30' n LEGEND: • EXPLORATORY BORING DRILLED FOR THIS STUDY. p EXPLORATORY BORING DRILLED BY CHEN-NORTHERN, INC., JOB NO. 4 177 93, DATED 1/4/93. 197228 1 HEPW RTH — PAWLAK INCI LOCATION OF EXPLORATORY BORINGS Fig. 1 8740 O BORING 3 \ �Q 4b / S L p BORING 4 BORING 2 \ \ \ BORING 1 _ EXISTING / I I I _ RESIDENCE (DASHED LINE) / PROPOSED RESIDENCE I , � \ \\ BORING 1 0 Cb BORING 2 r Lo 0 Ln 0 N n VO ^ ^� 00 m no CK) 197228 1 HEPW RTH — PAWLAK INCI LOCATION OF EXPLORATORY BORINGS Fig. 1 LEGEND: FILL; clay, sandy with scattered gravel, stiff, slightly moist, dark brown. TOPSOIL; clay and silt, sandy, organic,slightly moist, dark brown to black. CLAY (CL); sandy with shale fragments, stiff to very stiff, medium brown to yellow brown, medium plastic. 0 CLAYSTONE BEDROCK; interbedded and fractured, thinly bedded, steeply dipping, medium hard to very hard, slightly moist to moist, yellow brown to gray brown. Relatively undisturbed drive sample; 2—inch I.D. California liner sample. Drive sample blow count; indicates that 63 blows of a 140—pound hammer falling 30 inches were 63/12 required to drive the California sampler 12 inches. 2 = Depth to free water and number of days following drilling measurement was made. Depth at which boring had caved when checked on July 23, 1997. NOTES: 1. Exploratory borings were drilled on July 21, 1997 with a 4—inch diameter continuous flight power auger. 2. Locations of exploratory borings were measured approximately by pacing from features shown on the site plan provided. 3. Elevations of exploratory borings were based on topo lines on the site plan provided and were checked by instrument level. 4. The exploratory boring locations and elevations should be considered accurate only to the degree implied by the method used. 5. The lines between materials shown on the exploratory boring logs represent the approximate boundaries between material types and transitions may be gradual. 6. No free water was encountered in the borings at the time of drilling. Fluctuation in water level may occur with time. 7. Laboratory Testing Results: WC = Water Content ( % ) DD = Dry Density ( pcf ) —200 = Percent passing No. 200 sieve. LL = Liquid Limit ( % ) PI = Plasticity Index ( % ) 197 228 1 HEP E WORTH - AWLAK I LEGEND AND NOTES Fig. 3 a 2 C 0 in 1 v CL X W I 0 c 0 W N o_ E 0 U i Expansion upon wetting Moisture Content = 10.2 percent Dry Density = 124 pcf Sample of: Claystone Bedrock From: Baring 1 at 5 Feet 0.1 1.0 10 100 APPLIED PRESSURE — ksf 0.1 197 228 Moisture Content = 9.5 percent Dry Density = 132 pcf Sample of: Claystone Bedrock From: Boring 1 at 10 Feet Expansion upon wetting 1.0 10 100 APPLIED PRESSURE — ksf HEPWORTH — PAWLAK SWELL—CONSOLIDATION TEST RESULTS Fig. 4 GEOTECHNICAL, INC. X C .N° 0 C O CL X w 1 I C O_ N 2 N m 0_ E 0 U K r- 0 N 1 C O d X W 0 C O m aNi 1 CL E O U 2 LJ Expansion upon wettinq Moisture Content = 13.3 percent Dry Density = 110 pcf Sample of: Sandy Clay From: Baring 2 at 5 Feet 0.1 1.0 10 100 APPLIED PRESSURE — ksf Expansion upon wetting Moisture Content = 17.8 percent Dry Density = 106 pcf Sample of: Sandy Clay From: Boring 2 at 10 Feet 0.1 1.0 10 APPLIED PRESSURE — ksf 197 228 HEPWORTH — PAWLAK SWELL—CONSOLIDATION TEST RESULTS GEOTECHNICAL. INC. 100 Fig. 5 C 0 U) C D CL X w I c 0 co a� a E 0 U 4 3 2 J 1 2 i 0.1 1.0 10 APPLIED PRESSURE — ksf 100 197 228 1 HEPWORT — PAWLA I SWELL—CONSOLIDATION TEST RESULTS � Fig. 6 Moisture Dry Sample From: Content = 14.5 percent Density Weight = 118 pcf of: Claystone Bedrock Boring 2 at 15 Feet Expansion upon wetting 0.1 1.0 10 APPLIED PRESSURE — ksf 100 197 228 1 HEPWORT — PAWLA I SWELL—CONSOLIDATION TEST RESULTS � Fig. 6 U z J a U_ Z 2 U W F- 0 0 a J a a F- O CL W 2 U) H J D N W U) r� Vl LLQ U U U U a > O O O O J a) a) a) a) H °g m m m m Cl) a) a) a) c c c U U c O o O O U) n n m a n az m m U U U (n (nLU U °> x W w 2 Z o 5 O. U �- 2 O V) � U U w g o N � g a J 0 W m cc W z za> aCC n Lo 00 C) CC a 2 o_ Z a a 2 V) O a O 0 J W o Q _ It N I O CD 00 y H N M O F O W a a a Z � N LO M 0o Lli W _ w z O a7 O M d a o o 2 U O LO O Lf) o i " LO LO U O UN DEVELOPMENT AGREEMENT LOT R -86A, STARWOOD SUBDIVISION III. TDRs 3.1 TDRs. Section 3.210.10 of the Code allows for the use of TDRs to increase square footage of residential houses. The Code allows for the construction of houses with a maximum of 15,000 square feet of Floor Area as defined by the Code. The Code allows for the construction of larger houses by the use of one TDR for each additional 5,000 square feet of floor area for the residential dwelling. 3.2 CURRENT BUILDING TO BE MAINTAINED. In addition to the residential dwelling currently existing on the Property, which will be demolished to make way for the new single-family residential dwelling to be constructed on the Property, there is a four bedroom detached structure (the "Detached Bedroom Structure)" that will not be demolished and will remain in place as a legally constructed preexisting nonconforming use. The square footage of the Detached Bedroom Structure will be included in the total amount of square footage allowed to be constructed on the Property. 3.3 TOTAL SQUARE FOOTAGE. The Resolution approved Ziff's application for authorization to construct and maintain 36,170 square feet of residential floor area on the property. This figure includes 32,870 square feet for the main residential structure to be constructed by Ziff pursuant to this Development Agreement (the "Main Residence") (14,560 square feet for the first floor, 9,370 square feet for the second floor, 3,650 square feet for the mezzanine, and 5,290 square feet below grade, which excludes 4,000 square feet of basement space and 750 square feet of garage space, both of which are exempt under the Code from the calculation of allowable floor area.), 2,300 square feet for the Detached Bedroom Structure, and an additional 1,000 square feet to accommodate potential revisions to the design of the Main Residence. 3.4 USE OF 5 TDRs. The resolution authorizes Ziff to construct a residential structure 21,170 square feet above the normal 15,000 square foot maximum. This necessitates that Ziff use 5 TDRs at 5000 square feet per TDR. Because the fifth TDR would only be used to construct up to an additional 1,170 square feet, and because there is no procedure for dealing with fractional TDRs, Ziff may apply in the future to develop floor area equal to the unused portion of the fifth TDR. In such an event, Ziff will have to submit a new Development Application to the Board of County Commissioners, but he will not have to use a new TDR to the extent that he has additional floor area left over from the fifth TDR. 3.5 USE OF 4 OR LESS TDRs. In the event that Ziff's construction pursuant to this Development Agreement results in a total residential floor area (excluding basements and garages) of 35,000 or less square feet, Ziff will use less than 5 TDRs. By way of example, but not limitation, if Ziff shall construct say 32,000 square feet of floor area, he will use only 4 TDRs. Because the fourth TDR then would be used to construct less than 5,000 additional square feet, and because there is no procedure for dealing with fractional TDRs, Ziff may apply in the future to develop square footage equal to the unused portion of the Page 2 4 DEVELOPMENT AGREEMENT LOT R -86A, STARWOOD SUBDIVISION W less than entirely used TDR, if any. In such an event, Ziff will have to submit a new Development Application to the Board of County Commissioners, but he will not have to use a new TDR to the extent that he has additional floor area left over from the fourth TDR. 3.6 TDR PROCEDURE. Prior to the issuance of a building permit for construction pursuant to this Development Agreement, Ziff shall obtain the number of Certificates of TDR Rights from the Community Development Department necessary to accommodate the size of the Main Residence, the Detached Bedroom Structure, and any other construction pursuant to this Development Agreement. Ziff will execute whatever documents are necessary in order to comply with any regulations or procedures of the Community Development Department established relating to the issuance and/or redemption of Certificates of TDR Rights. IV. BUILDING ENVELOPE 4.1 BUILDING ENVELOPE. Attached hereto as Exhibit A is a diagram of a building envelope for any building construction pursuant to this Development Agreement. All residential building construction pursuant to this Development Agreement shall occur within the building envelope. As long as all construction pursuant to this Agreement is within the building envelope, Ziff may make revisions to the actual footprint of the residential structure without any further review by the County. This envelope is for the residential building only, and is not meant to confine the utilities, I.S.D.S., sidewalks, or grading. The County agrees that subject to applicable provisions of the Code, Ziff may landscape the Property outside of the approved building envelope without further review of approval. V. BUILDING AND DEVELOPMENT CONDITIONS AND REQUIREMENTS 5.1 APPLICATION OF ENERGY AND BUILDING CODES. Ziff shall comply with the applicable requirements, of the Aspen/Pitkin County Energy Conservation Code (APECC) in effect at the time of BOCC approval and up to 18 months after the BOCC approval given on May 9, 1997. Should the building permit submittal be received by the Building Department more than 18 months after the date of the BOCC approval, Ziff must comply with the APECC in effect at that time. 5.2 UNIFORM BUILDING CODE. All construction pursuant to this Development Agreement shall conform to the requirements of the Uniform Building Code in effect at the time Ziff shall apply for a building permit for such construction. Page 3 4 DEVELOPMENT AGREEMENT LOT R -86A, STARWOOD SUBDIVISION 5.3 LIGHTING. Ziff shall comply with the lighting standards of Section 3-110.110 of the Land Use Code for any construction pursuant to this Development Agreement to assure that any lighting impacts associated with any development pursuant to this Development Agreement will be minimized. 5.4 SLOPES. For development on any slopes for any construction pursuant to this Development Agreement, Ziff shall adhere to the following standards: A. Adequate mechanical support shall be provided for all slopes. B. Adding water which may decrease slope stability shall be avoided. C. Adding weight to the top of the slope shall be avoided. D. Disturbed slopes shall be contoured so that they can be revegetated. E. Steepening of existing slopes shall be avoided to the extent reasonable. F. Cuts, fills, grading, and excavation shall be confined to the minimum area needed for construction. G. It is acknowledged that the provision of the Code relating to 1041 review does not apply because the Property is situated in a subdivision approved by the County. 5.5 LANDSCAPING AND REVEGETATION PLAN. Ziff shall provide a detailed landscaping and revegetation plan which generally includes, but is not limited to, the quantity, species and locations for all plant materials in the immediate vicinity of the residence. The landscape plan shall also include information on the seed mixtures to be utilized for revegetation. The plan shall be reviewed and approved by the Community Development Department and the County Land Management Department, prior to the issuance of a building permit. 5.6 REVEGETATION OF AREAS DISTURBED BY CONSTRUCTION. All areas disturbed by any construction pursuant to this Development Agreement shall be revegetated within one growing season after the completion of construction. 5.7 SEPTIC PERMIT. Ziff shall obtain all required septic permits from the State of Colorado, and/or Pitkin County prior to the installation of any septic or sewage disposal system pursuant to this, Development Agreement. Prior to the issuance of a septic permit for any construction pursuant to this Development Agreement, Ziff shall provide documentation of an adequate domestic water supply for the proposed residence and the Detached. Bedroom Structure. 5.8 WILDFIRE MITIGATION. Ziff shall use the following Wildfire Mitigation for any construction pursuant to this Development Agreement: Page 4 I ' % Z p COLORADO RENOVATION T, > , 0 Nn 5� 6Q a m 4z c ASPEN, CO f vo 0 CP 'x --- ------- ------- N HN 7-o )j' k7 '14 Z, 0, Al N, 5 i ie k-4 � _ Ir - q r� (r � �;1��� ,'i 4 rf� �/ � /' �`- / �''�-' _..._. � - _ ` I ` r '' `' 1� �(1 , r V Cb 1yo cp Pl 1po -- — — ---------- J.r, rill N, f ------ J:p cp LS w 12 Nj Aon � � __—_—_ �� a =m _ I ' Z p COLORADO RENOVATION pn I > < , 0 Nn 5� 6Q a m 4z c ASPEN, CO CM I � I (� � a T 2 r - a D �Z N 6, (> �,NNn9aNN COLORADO RENOVATION p� A g�AF=m y pZ O g ZKRoZ Z ASPEN, CO �Nh :A n c z b ` D71 Z O m N >�� COLORADO RENOVATION NNF O II m m o Wzo pZ O ASPEN, COQ °A r W = 0 a D T .Z 4 � m N Ar�� p� COLORADO RENOVATIONp� =A 0 II D Z rT- o >Z 00 0 o z ASPEN, CO gNNo m 264-3261 02 001 *26104002 26432 6401002 264-326103002 1020 ®I ■ . o 9RA LAP EAST i1A CC*KNFK .1&, t>., R85v. (A REPLA T F on FiFTF-F I f—i i 0 LOT R-86 S IARW.0 6-01 0 sit I %""c--Nw/ N Q i Db 200 300 400 500 F�T, E�Ac->15 OF t5FA(ZVNc-;ue). C. 4 G.S. A;59,Etlt —10 4SP N , t tvtt Ti 4 5a� Z , EIE PA.T e ' F :E?5 7, i�}77 RECORDING fF�T IQATE WITN555 ` ,\( "SND AND Crff CAL 5) 11 , STATE. OF COLaDO COUNTY OF PfTNN 71 -IE nREC—O NC 1, 5T[-rUMD4T-Wi��5ACKNOWLEDGLD .SES . 'WfTNE55 MY f AND !WD OFFICIAL &--AL , JRUE` OK5 CERTIFICAT.. i, J/�ME.5 F 5 ; FtGl5Tl�RF-D �,AN.D .5URVEYOR, DU ,�IEREBY C- MKT] ` Y 'R -AT TH15 EMPTION PLAT Off LOT T� 5G -f1, 5TAR\1OM'1t=TEEN I WA5 EPARED UNDEF� MY SUPEFVi,5 N AND THAT 7HE C U75DE »i -CAR I E, ROAD5 /WD OTNEK F=-1L'RE5 ARE ACCIL1t?ATIELY,A,N`D C099ECTLY,5-0WN HEREOti i vAT THE MME RKE f5A5ED ON 1=1ELD 50RVEY51 A,\�D THAT THIS- PLAT7FD LOT C0NI`0RM5 70 TH/ ET 5TAI<D ON Th E. G UNF). IN W1,7NE55 WHERM II 1 %-AVE �T MY ti'D &qD S�°L Us 64 7i la 60 L TnGTIVOCVC-MANT5 f0I� THE 5TP� D SU5tDfVI5[0N5 FEM;O D RAS L,s 1N K 211 A`AGF- 23! OF THE PITKIN COUNTY ' RLCC7RQ51. : 5.47 MODIFIED �Y N TC�UI�ENT KE G GED IN ��OK 2C.1 AT F','G�4� �'�` T - 48:47 L= � x.50 9-10:00 webT OF SUCI-I RECOFU1 AND�� "LL� C0N4&CtRED A5 ONE. iNQV Q 50/OF ��DL��VTY C Mi�''i55laN�I�51��'KQ�/�L Uv�L t FE, I:M l AL TRACT r0K ALLPUKFQ5E5 C f k5, I0 PffoTEMVE. ! 47 U3 L3t�'gin/ 5�> o = 2a34`oo" COVr-NANT5/ AN:p.T 'i E lute T iO I v LC1t ,R -n TEEN, D DO �IEREW C VI•✓Y CK KMEF E-tAf 57 QF- CA MAY 5F- NA5 5EFN Kr-VILWED AN[( ) /\�OUE7 �3Y THE PITKI1t COUNTY TO Tf11 iVOC �i LANA RATDN OF COQ ORAL AL iT OI TI tERDC 1 C % 111 1C NI= zS TN I5 D1 \(0f --= S�MENTS PESCRIf!t-D INART[CLE. TX C f-,5AI: "7 P TECTIVE-I -78 TN1:5 APPROVAL L i S EX CI N`D TO uTILITfES 11r`� TE R` &4.00 C0VE:Nf\NT5 UFON C7R RO ALL CF' T�iE L AND5 tN LOT ' A CA51FCML 5Y5Tr-Mt C9 ANY SE, tf( L ''�ACILITIE STfflMOM, FII" TEIwN, PI T NiN CCaUNTY, COL MDD. L-= too. = 5.5 EXECUTED T�-�{I�. ��1Ya� - I��B � CI--I<�if��/I}�hi -Fy �ITKI N GC�I.�I`t f��f� D 0� -T ; _.4�.kkc�o/�yy EI ST�1�N vii . f S-1AKWC0D LAND MMRAMON OF CoLop"41DO RECORD DRAWING NOTE: FIELD DIMENSIONS PROVIDED HK EARTHWORKS CONSTRUCTION (CONTRACTOR) RECEIVED 09-2J 7RCED I MESH FLOW TO BEDS SCALE: 1 "= 30' RECORD DRAWING ISDS FOR ZIFF RESIDENCE 4 " PVC TO EACH DISTRIBUTION LINE 56' 4 " HEADER PIPE (TO BE LEVEL) 4 " PVC FROM HOUSE 56' BED PLA N INFILTRATOR LINES (9 UNITS EACH LINE) SLOPE AT 2: 1 TO EXISTING GRADE OR TO BED (TYP.) CLEAN-OUT DETAIL SANDY TOPSOIL VARIES FROM 12" AT CENTER TO 2" AT EDGES SAND 0 N '4 " PERFORATED PVC DISTRIBUTION PIPING 2" OF SAND OR SUITABLE ON—SITE —/ MATERIAL APPROVED BY THE ENGINEER ''-- 3" TEE )NCRETE /PPORT )LLAR FLOW FROM HOUSE 3 " SWEET AIR CHARCOAL FILTER (OR APPROVED EQUAL) 4 "AIR VENT r—SE ED TOPSOIL AIR VENT DETAIL NOT TO SCALE nnI BOTTOM OF BED SHALL BE LEVEL WASHED SAND 0.1 f, SCARIFY BEFORE PLACING SAND m L. 4 " PERFORATED PVC 2' SAND SLOPE O'%FT. (TYP.) BED SECTION SCALE: 1"- 3' EXISTING GRADE SLOPE AT 2:1 MAX. TO EXISTING GRADE OR TO BED (TYP.) PROVIDE SWALE TO DIVERT RUN-OFF AROUND E. T.A. BED SLOPE AT 19' MIN. TO DAYLIGHT 2.5' 5' 5' 5' 2.5' SANDY TCPSOIL FROM 12 TO 2" AT VARIES ' AT MIDDLE S1DES -r---- AIR VENT (4 R SEE DETAIL ---y- Q'D) p p r 'fi BOTTOM OF BED SHALL BE LEVEL WASHED SAND 0.1 f, SCARIFY BEFORE PLACING SAND m L. 4 " PERFORATED PVC 2' SAND SLOPE O'%FT. (TYP.) BED SECTION SCALE: 1"- 3' EXISTING GRADE SLOPE AT 2:1 MAX. TO EXISTING GRADE OR TO BED (TYP.) PROVIDE SWALE TO DIVERT RUN-OFF AROUND E. T.A. BED SLOPE AT 19' MIN. TO DAYLIGHT Q M R Q CO .a 3 C7 N 3 M3 OR Planter Io?7ter o000° Steps000 / Doan �' o° j� °o °t3 Steps 00 000 ° o° Flagstone 00 v� Ste s Steps \ ` oncrete N Steps 3500 GAL IV EP77G ANk la �� ► Vial � R eta i i gVa Ix 4 " PVC `(AS))�l( ; 4)0 2 MIl1�, SLOP L£ANO r ( \ E'ect?ic 0 Tra»sf-'rm & Meter ` \ y', o � Z J s z� tzi q� \ \V X, SLA N Ci N T ORB �0 � OOR S7ASIZIZA77ON. EOUIR -")B N Pf'ER- LOWER SCALE: 1 "= 30' 1 INLET 7 OUTLETS CONCRETE REINFORCED WITH 6--6 10-10 MESH DISTRIBUTION Box 2.0" 2.0" FLOW TO BEDS 4" PVC TO EACH DISTRIBUTION LINE 56' 4 " HEADER PIPE (TO BE LEVEL) '�2 LZ GENERAL NOTES:• 1. ALL MATERIALS, INSTALLA77ON PRAC77CES, SETBACK REQUIREMENTS, ETC., I SHALL COMPLY WITH THE PITKIN COUNTY 11"10/VIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS. 4" PVC FROM HOUSE { Z THE E. T.A. BED SHALL BE CONSTRUCTED SO THAT THE BOTTOM IS LEVEL 56' +/-0.1 : PLACE BED IN NATURAL GROUND, NO PORT70N OF THE BED SHALL SE PLACED IN F7LL. 3. PROVIDE ADEOUATE SURFACE & SUBSURFACE WATER DIVERSION TO ASSURE THAT RUN-OFF DOES NOT ENTFR THE EV4PO-TRANSPIRATION-ABSO.RATIO�J BED IF SUBSURFACE WATER IS ENCOUNTERED, NO77FY ENGINEER. 4. STONE SHALL BE 1/2" TD 2 1/2' SCREENED ROCK. 5. SAND SHALL BE 0.04 TO 0.28 MM EFFECTIVE SIZE WITH A UNIFORMITY COEFFICIENT OF 4 OR LESS. PROVIDE SIEVE ANALYSIS TO ENGINEER FOR REVIEW. 6. THE RECOMMENDED BED SEEDING IS S4LT RESISTANT FESCUE AT 4 TO 6 LBS. PER INFILTRATOR LINES (9 UNITS EACH LINE) 1000 SQ.FT. ALL OTHER AREAS DISTURBED BY CONSTRUCTION SHALL BE RESEEDED WITH NA77VE GRASSES TO PREVENT EROSION. 7. THE LOC477ON OF THE BED MAY BE ADJUSTED IN THE FIELD TO BETTER FIT THE SITE, PROVIDED ALL SETBACKS ARE MET. CONTRACTOR SHALL VERIFY LAYOUT ACCOMMODATES SITE SLOPE. 8. DRAIN HOLES IN 4" PERFORATED PIPE TO BE AT 60" SPACING (2 HOLES PER SPACING, 1/4" DIA. LOCATED DOWNWARD) OR ASTM 2729 PERFORATED PIPE: 9. 4" PVC TEES SHOULD NOT BE GLUED TO ENABLE OBSERVATIONS OF WATER LEVEL IN SY57EY AND TO REMOVE EXCESS SALTS ACCUMULA7701V OR SURPLUS ""T' 7F ir'cri^.ES` TRY. 10. USE RISERS AS NEEDED TO BRING SEPTIC TANK ACCESS HATCH WITHIN 6" OF F7NISHED GRADE. 11. SDR J5 PVC PIPE OR PIPE OF EOUAL STRENGTH OR OTHER PIPE PROPERLY SUPPORTED TO PREVENT FAILURE BY SETTLING SHALL EXTEND FPO" ALL TANKS FOR A DISTANCE OF AT LEAST F7VE FEET (5) FROM THE INLET AND OUTLET ENDS. 72. THE CONTRACTOR AND OWNER SHALL TAKE WHATEVER MEASURES ARE NECESSARY TO ASSURE THAT (a) SEP77C TANK AND SEWER LINES ARE COMPLETELY WATER 77GHT, AND (b) THE SYSTEM IS TO BE INSTALLED TO PREVENT FREEZING OF ALL PRESSURE AND GRAVITY SEWER LINES. 13. TRE PITKIN COUNTY ENVIRONMENTAL HEALTH DEPARTMENT AND THE ENGINEER SHALL BE NO77F7ED WHEN CONSTRUCTION COMMENCES AND KEPT ABREAST OF THE CONSTRUCTION PROGRESS SO THAT SU'77CIENT INSPECTION CAN BE PERFORMED TO ASSURE CONFORMANCE WITH THESE PLANS. PROVIDE A MINIMUM OF 48 HOURS NOTICE TO EACH, 14. PVC SEWER PIPE SHALL BE SDR 35 IN ALL TRAFFIC AREAS, ASTM 2729 PVC ELSEWHERE- 15. THE SURFACE OF EACH BED SHALL BE PROPERLY MOUNDED PER THE DRAWINGS P TO ENSURE THAT PRECIPITA7701V OR SNOWMELT WILL RUN OFF THE REDS. 16, SURFACE GRADING SHALL ROUTE RUNOFF AROUND AND AWAY FROM THE BEDS. DESIGN CALCULATIONS 1. 4 BEDROOM HOME (4000 SF), USE 2 PERSONS/BEDROOM AND 730 Gill 2. DETERMINE FLOW O (DAILY) = (1.75)(2)(4)(130) = 1820 GPD J. SEPTIC TANK SIZE FOR 4 BEDROOMS = 2500 GALLOIVS; 4. ALLOWABLE LOADING RATES: DESIGN FOR COMBINATION ABSORPTION/EVAPO-TRANSPIRATION mac° METHOD OF EFFLUENT DISPOSAL. P FERC TEST RESUL TS.• 54 MINUTES/1/VCH EVAPO- TRANSPIRA TION: USE ET RATE OF ,32 %YEAR 5. DETERMINE BED SIZE: FOR ABSORPTION: O = 5 * (AREA)/SOR7-(54) 5N6 6 FOR EVAPO-TRANSPIRATION: y. c� 0 = 32 7/YR * (AREA)/586 6. COMBINE EQUATIONS AND SUBSTITUTE.- O(ABSORPRON) f 0(ET) = 1820 GPD 0.6804(A) 4- 0.0545(A) = 182C GPD osq)A c'-1 A A = 2476 SF. INSTALL (2) 20' X 172' BEDS, EFFECTIVE AREA = 4480 S.F. )NCRETE IPPORT X LAR FLOW FROM HOUSE MATERIAL APPROVED BY THE ENGINEER SLOPE AT 2:1 TO EXISTING GRADE OR TO BED (TYP.) Alm VENT DETAIL NOT TO SCALE Lv 2.5' S' 5' 5 2.5' SANDY TC PSOIL VARIES \,'J AIR VENT (4 R 01D) FROM 12 AT MIDDLE SEE DETAIL TO 2" AT SIDES---�- t7: BOTTOM OF BED SHALL BE LEVEL WASHED SAND 0. 1 f, SCARIFY BEFORE PLACING SAND ENGINEERS SCHMUESER GowoN MEYER INC. LOTS R86 STARWOOD SURVEYORS GM 118 w. 6th srREEr, sUirE 200 ZIFF RESrDENCE GLENWOOD SPRINGS. COLORADO 81601 OU ESER(303) 945-1004 (FAX.) 945-5948 MEy�-R ASPEN, COLORADO (303) 925-6727 PITKIN COUNTY COLORADO REVISION L 4 " PERFORATED PVC 2' SAND SLOPE 07FT. (TVP.) BED SECTION SCALE: 1 '= 3' DATE I BY EXISTING GRADE SLOPE AT 2:1 MAX. TO EXIS77NG GRADE OR TO BED (TYP.) PROVIDE SWAtr TO DIVERT RUN-OFF AROUND ETA. BED'- SLOPE AT 1, Y//V. TO DAYLIGHT ' 3 INDIVID UAL ,SEWA GE DISPOSAL SYSTEM Job No. 9008 Drown by: a/C Date: 02/28/00 APPn by. DJC OF -I- Fl-le: ZIMSDS