HomeMy WebLinkAboutpitkin.eh.264326402011 (1999)Permit # 99100
Aspen/Pitkin Environmental Health Department
Permit for an Individual Sewage Disposal System
130 S. Galena St. Aspen, Colorado 81611
Phone 970-920-5070 / FAX 970-920-5074
Parcel ID # 2643-264-02-011
Type of permit New( ) Repair( ) Addition to House( X )
Name of Owner
Judith Barnard & Michael Fain
Street Address 0152 Buchanan Dr
Property legal description Lot R-2 Starwood
Size of lot 2.5 acres
Total square footage of the house
6390
Water source Starwood Water
# of bedrooms in house 4 # of offices, lofts & similar sized rooms in house
Caretaker unit n/a
# of bedrooms in caretaker unit
Designed for what # rooms (list)
Designed by
Total square footage of the caretaker unit
# of offices, lofts & similar sized rooms in caretaker unit
FOUR (4) bedrooms
Church & Associates, Inc.
Permit information
Mailing Address 4501 Wadsworth Boulevard, Wheat Ridge, CO 80033
Perc rate 28 mpi Profile hole depth 8 ft Depth to groundwater or bedrock
Septic tank capacity 2275 gallons Absorption area .1926 sq ft
Comments
+8 ft
Septic permit approved per compliance with the engineer design and specifications dated November 19, 1999 and
revised Figure 3 showing detail of the three distribution boxes and distribution of 75 % of effluent to new
field and 25 % to old field. Existing "gray water" system is to be abandoned. Existing black water system is
to be enlarged by the addition of one 2000 -gallon single compartment tank and three gravelless chamber beds with
a total of 64 units. Any changes must be approved by this department and the design engineer prior to them being
made.
Minimum horizontal distances between components of the system and physical features shall conform to the Pitkin
County ISDS regulations.
This department does not endorse any brand of products.
The engineer must do a. final inspection of the installation and submit an as -built letter to this department. This
department must also be called for an inspection with a minimum of 48 hours advanced notice.
Permit approved by: ' 4 s< Date: ^/1 - — `/
Plans and specifications of the pro osed individual se age disposal system have been reviewed and are considered
satisfactory. Permission is hereby granted to the owner or the agent to perform the work indicated in accordance with the Pitkin
County ISDS Regulation in effect at the time of issue. This permit becomes invalid 6 months from the date that the permit was
issued unless system construction has commenced or an extension has been approved in writing by the Department.
As -built drawings must be included with this permit before the final approval will be issued.
Installer:
Final inspection approval: Date: v
ASPENIP1 i 1 � ENVIRONMENTAL HEALTH DEPA �1tiENT
APPLICATIO►I. )R INDIVIDUAL SEWAGE DISPOSi ,wjYSTEM
130 S. Galena St., Aspen Colorado 81611 JOB NAME
Phone 970-920-5070/Fax 970-920-5039 CC= CCD7
.�/ F. I W. t
Name of CWNER
Owner's Mailing Address �� 2 � �'►'+' N � � � ,� '
Business '-hone: /v - 2S- S c, Home Phcne: 710 2s
Primary Contact Person (ail communication regarding this permit will go through this person)
Name 77AI Al Ygef
Company 4W/07W47^,/ /4 G
Contact Mailing Address 280 e. C040V G ;?4,r4cf eb $/62/
Business Phcne : f:;k7-. //`/ Call Phone: 3? - 102 Fax 970-1-27-3374
Parcel ID r (available from assessor's office
at 920-5160 or at www.aspen.com/assessor�
Street address of property 0162- 81
.1v mil1/a Arra - e'o
Legal Description: Lot ,Block Fiiir,g Subdivision J isWrWAIu i
Size of'et: acres. Type of proposed structure: Size of bldg. envelope:
Total square feet of house SD of bedrooms in house 3
T of offices, lofts & similar sized rooms in house Z
Caretaker Unit: Attached ( ) Detached ( ) Total area(sq. ft.) of caretaker unit NG�lc I
of bedrooms in caretaker snit : of offices lofts and similar size rooms of caretaker unit
Permit is for: New Home ( ) Repair due b failure ( ) Remodel/Addittonx Emergency use ( )
Water: Private well ( ) Sprang ( ) Stream ( ) Community/Public Water System ( )
If community system: Name of system
The fee for a ISDS application is $330 for a permit that takes 6 hours or less for the department to approve. If approval takes
longer than o hours, a rate of S55 per hour will be charged. The maximum fee is S1000. The basic fee of 5330 is due at the time
of application. The remainder, if any, will be due in two stages: first, at the time of issuance of the !SDS permit: second, before
final approval of the ISOS permit.
Application for an individual sewage disposal system is hereby submitted. I hereby certify that the above information, is true and
accurate and that I have provided true and accurate information on locations of all existing and proposed Neils, contour
intervals, buildings, property lines, ditches, slopes, waterlines, springs, suction or irrigation lines, drinking water cistems, drain
tiles, irrigation ditches, lakes, water courses, streams, floodplains, dry gulches, and existing septic systems. I hereby certify
that any such features not shown on attached site map are not present. Issuance of the permit does not imply the approval of
any other permit required for construction pursuant to Pitkin County codes. No construction may be undertaken until all
approvals and permits have been obtained.
The Aspen/Pitkin Environmental Health Department, Pitkin County and employees of these agencies will be held harmless
should the individual sewage disposal system fail or malfunction. The permit to construct is issued on information submitted by
the applicant or his/her representatives. The owner assumes full responsibility in case of failure of the system.
Signature of applicant
Received by
Date �4-25=99
Receipt # �ZF�' Date ;
December 20, 1999
Bill Poss & Associates
Attn: Richard DeCampo
605 East Main Street
Aspen, Colorado 81611
Associates. Inc.
ENGINEERS & GEOLOGISTS
Subject: Installation Observations, Barnard/Fain Residence
0152 Buchanan Drive
R-2, Starwood Village
Pitkin County, Colorado
Job No. 11839
Dear Mr. DeCampo,
As requested, we observed the installation of the onsite wastewater system (OWS) for the subject site on
December 7, 1999. The system was designed under our Job No. 11839, dated October 18, 1999.
The system includes the installation of a 2000 -gallon, single -compartment, pre -cast concrete septic tank,
a pump in a Biotube vault in the existing 1250 -gallon tank, a distribution box, and four chamber -beds. The
total infiltrative area, including the existing field, is 1558 SF. An as -built drawing is included as Figure
1.
The pump, alarm, and Biotube vault are in place and wired. Harriman Construction activated the pumping
system on December 15, 1999. The components of the OWS were installed in conformance with the plans
and specifications.
If there are any questions or if we can be of further service, please call.
Sincerely,
CHURCH and
t�L
Edward O.
EOC/trp
fir:•"'••'•v%A
7Y31Z(
.g
��4NAt E�
2 copies sent
copy to Harriman Construction, Inc., Attn: Tim Meyer, 409 Aspen ABC, Aspen, CO 81611
QENVER 4501 Wadsworth Boulevard Wheat Ridge, CO 80033
303.463.9317 Fax: 303.463.9321
CASTLE ROCK 303.660.4358
EVERGREEN 303.816.1455
r--1
alle� kl7
3
16 1 �
w,.A rll_
-- --------
41
4;4Z/
7 8-
-�-.2-
1-7 1 7 . /,U '2-
AN
ASPEN/PITKIN ENVIRONMENTAL HEALTH DEPARTMEovT
ISDS DESIGN REQUIREMENTS -DEPARTMENT USE ONLY
Name
House Size (75 gpd, 100 gpd, or 130 gpd)
#of Bedrooms, Similar Rooms accessible to baths in Main Residence
# of Bedrooms, similar rooms w/ access to bath in ATTACHED caretaker
# of Bedrooms & Similar Rooms w/ access to baths in DETTACHED caretaker
Average Daily Waste Flow 600 # bedrooms X 2 people/br X 75
State Review Required? no
Perc Rate 28 (T) 3 equals # of Perc Holes Required
Design Flo w (Q) = # bedrooms X 2 people/bedroom X gpd X 1.75
Q= 1820
Minimum tank capacity 2275 gallons
Absorption Area (A=: Q/5 X SQRT)
A = 1926 sq. ft. of absorption area required
124 infiltrator units without reduction
A maximum 30% reduction is allowed for use of deep gravel or gravelless chambered system.
1348 sq.ft. with reduction
87 infiltrator units with reduction
AREA NEEDED FOR STANDARD ABSORPTION TRENCHES
642 1926 Total sq ft /3 =lineal ft of trench needed
130
4
11 642 lineal ft/assumed trench length of 60ft = # of 60ft trenches needed
10 # trenches minus 1 = rows of 6ft wide undisturbed soil between trenches
33 11 times 3 = total width of of 60" long field needed for just the trenches
60 10 times 6' = total width of 60' long field needed just for undisturbed soil
93 width of trench +width of undisturbed soil = total width needed
93 by 60 ft is the area needed for a standard absorption field in a trench configuration with no
reductions taken and ASSUMING AN AVERAGE PERCOLATION RATE OF 28
SLOWER PERCOLATING SOILS WOULD REQUIRE MORE AREA.
SETBACK FROM WELL SETBACK FROM POND, STREAM OR IRRIGATION DITCH
# of feet = 165.6 # of feet = 115.6
SETBACK FROM DRY GULCH
# of feet = 90.6
Remember: 8 feet of additional distance for each 100 gallons/day of design flow over 1,000 gallons/day
should be added unless an RPE can verify that it is not necessary to prevent contamination.
1/20/99
Printed on Recycled Paper
ASPEN/PITKIN ENVIRONMENTAL HEALTH DEPARTMEiv F
ISDS DESIGN REQUIREMENTS -DEPARTMENT USE ONLY
Name —
House Size (75 gpd, 100 gpd, or 130 gpd) 130
#of Bedrooms, Similar Rooms accessible to baths in Main Residence 4
# of Bedrooms, similar rooms w/ access to bath in ATTACHED caretaker
# of Bedrooms & Similar Rooms w/ access to baths in DETTACHED caretaker
Average Daily Waste Flow 600 # bedrooms X 2 people/br X 75
State Review Required? no
Perc Rate 28 (T) 3 equals # of Perc Holes Required
Design Flo w (Q) = # bedrooms X 2 people/bedroom X gpd X 1.75
Q= 1820
Minimum tank capacity 2275 gallons
Absorption Area (A= Q/5 X SQRT)
A = 1386 sq. ft. of absorption area required
89 infiltrator units without reduction
A maximum 30% reduction is allowed for use of deep gravel or gravelless chambered system.
970 sq.ft. with reduction
63 infiltrator units with reduction
AREA NEEDED FOR STANDARD ABSORPTION TRENCHES
462 1386 Total sq ft /3 =lineal ft of trench needed
8 462 lineal ft/assumed trench length of 60ft = # of 60ft trenches needed
7 # trenches minus 1 = rows of Eft wide undisturbed soil between trenches
24 8 times 3 = total width of of 60" long field needed for just the trenches
42 7 times 6' = total width of 60' long field needed just for undisturbed soil
66 width of trench +width of undisturbed soil = total width needed
66 by 60 ft is the area needed for a standard absorption field in a trench configuration with no
reductions taken and ASSUMING AN AVERAGE PERCOLATION RATE OF 28
SLOWER PERCOLATING SOILS WOULD REQUIRE MORE AREA.
SETBACK FROM WELL SETBACK FROM POND, STREAM OR IRRIGATION DITCH
# of feet = 165.6 # of feet = 115.6
SETBACK FROM DRY GULCH
# of feet = 90.6
Remember: 8 feet of additional distance for each 100 gallons/day of design flow over 1,000 gallons/day
should be added unless an RPE can verify that it is not necessary to prevent contamination.
1/20/99
Printed on Recycled Paper
8
0 cQrv-i,gbnQ
November 19, 1999 ENGINEERS & GEOLOGISTS
Bill Poss and Associates
ATTN: Les Rosenstein
605 East Main Street
Aspen, Colorado 81611
Subject: Revised OWS Upgrade Design, Barnard/Fain Residence
Lot R-2, Starwood Subdivision
0152 Buchanan Drive
Pitkin County, Colorado
Job No. 11839
Dear Mr. DeCampo,
As requested, we are providing this revised Onsite Wastewater System (OWS) upgrade design for the
subject site. The revision is for a relocation of the OWS based on additional percolation tests from our
October 18, 1999 design report. This letter should be used as an addendum to our original design. This
letter includes three revised figures - Figures 2 through 4; a percolation table - Table 1; and a pump curve.
The original Figures 2 through 4 should be removed to avoid confusion.
SITE CONDITIONS
The property is located in a rural residential area in Pitkin County, where OWS are required. The proposed
drain field area has a 20% slope to the southwest, and a cover of native grass with clusters of scrub oak.
The main residence has an existing gray water and black water OWS as indicated on Figure 1. The existing
"black water" system consists of a 1250 -gallon septic tank, a dosing siphon in a 500 -gallon tank, and an
equivalent 597 square foot (SF) "deep gravel' trench OWS. The three -feet of "deep gravel' allows a 30%
increase of the 459 SF of the field. The existing OWS was permitted in 1993. There is also a "gray water"
OWS for washing machine facilities, which will need to be abandoned, as the entire sewage treatment will
be directed through one system. The residence is served water by the local water district.
PROPOSED CONSTRUCTION
The existing residence has greater than 6000 square feet (SF) and will be remodeled to have a total of 4
bedrooms. We have sized the OWS based on 4 bedrooms and 1040 Gallons Per Day (GPD) using Aspen/
Pitkin Environmental Health Department (APEHD) loading of 130 gallons per day per person. The sewage
loading with a peaking factor of 1.75 is 1820 GPD. This loading includes a dishwasher and garbage grinder.
We are proposing to abandon the existing gray water OWS, and upgrade the existing "black water" OWS
to accommodate the entire residence.
SUBSURFACE CONDITIONS
We performed supplementary percolation tests at the locations indicated on Figure 2. Percolation tests
indicate percolation rates of 15 to 40 minutes per inch (MPI), in holes P-7 through P-9. The average
percolation rate is 28 MPI. A profile test pit was excavated at the location indicated on Figure 1.
Subsurface conditions exposed consist of 1 foot of sandy clay topsoil root zone underlain to 8 feet by
very stiff sandy clay, which was reddish brown to brown. No free water or evidence of a seasonal high
water table was observed in the test pit.
DENVER 4501 Wadsworth Boulevard Wheat Ridge, CO 80033 CASTLE ROCK 303.660.4358
303.463.9317 Fax: 303.463.9321 EVERGREEN 303.816.1455
n
RECOMMENDATIONS
Revised OWS Upgrade Design
Job No. 11839
Page 2
We recommend the installation of a septic tank and three chamber -type drain field beds installed at the
locations presented on Figure 2 to expand the existing OWS. The OWS design is based on an average
sewage load of 1820 GPD and a percolation rate of 28 MPI. The existing OWS has effective area totaling
540 fC. This drain field will be used in conjunction with the proposed fields. We recommend the installation
of one 2000 -gallon single -compartment, concrete septic tank to be placed in front (up -gradient) of the exist-
ing 1250 -gallon septic tank and dosing tank. A duel effluent pumping system should be installed in the
dosing tank to replace the dosing siphon. Two `new' distribution boxes are to be placed as indicated on
Figure 2 to distribute effluent to the existing distribution box and the proposed drain fields. Three gravelless
beds should be installed, the two beds of `A' having 2 rows of 11 chambers and the `B' bed having 2 rows
of 10 chambers.
The required area for a drain field for the proposed residence would be 1926 SF. The equivalent area
of the existing black water drain field is 540 SF, which was subtracted from the 1926, resulting in a
required area of 1386 SF. A 30% reduction of the 1386 SF area was taken for use of chambers, result-
ing in a required area of 970 SF. It is proposed to add 970 SF of drain field in three chamber beds.
DRAIN FIELD PREPARATION
Vehicular movement over the drain field area during construction should be kept at a minimum to
avoid compaction of the receiving soils. Dump trucks and rubber -tire backhoes are to be kept out of
the field excavation. We recommend the bottom of the bed be scarified with a pick, shovel, or backhoe
bucket teeth prior to the addition of dispersal gravel.
LIMITATIONS
An OWS design should be installed by a contractor who is experienced in its installation. Our layout, design
and recommendations are based on data submitted. If subsurface conditions different from those described
in this report are encountered, we should be notified to evaluate the effect on the proposed OWS. If the
health department makes modifications to this design, we should be contacted to evaluate the impact on the
performance of the OWS. The county and our firm must be contacted upon completion of the OWS. All
construction is to be in accordance with the ISDS regulations. Pipe type and size, burial requirements, septic
tank construction, and other specifications, which are not depicted in our report, are to conform to the
requirements of the ISDS regulations. The installer of the system is to have demonstrated knowledge of the
APEHD ISDS regulations and requirements.
CHURCH & Associate O0 REG' 1.
o . • 9� o
Roger J. Shafer, P.E.
RJS/trp AtE�
3 copies sent
Fax copy to: 970.920.5070, Attn: Nancy
Fed Ex copy to: Tim Meyer
280 East Cody Lane
Basalt, CO 81621
Duplex Effluent Pumping System
Slope Ground
Away from Riser
Inlet Tee
Patents # 4,439,323 & 5,492,635
Foreign Patents Pending
/--PVC Riser with Grommets
(bond to tank adopter with
recommended adhesive)
Fiberglass Gosketed Lid with
Stainless Steel Bolts Discharge Assembly
PVC Splice Box
with Cord Grips Flexible Hoses (2)
Conduit to Effluent Discharge
Control Panel —
Conduit Seal
Tank Adapter (cost or bolted)---\\
Level Control
Liquid Level v I 4.VT-- Float Assembly
Check Valve (optional)
Vault Inlet Ports
Flow Inducer (2)
CSI Effluent Pump
Drain Port
Filter Cartridge
Bictube® Pump Vault
v�
•
0-0
Orenco Systems®
Incorporated
814 AIRWAY AVENUE
SUiHERUN, OREGON
97479-9012
TELEPHONE:
(541) 459-4449
FACSIMILE-
(541)
ACSIMILE(541) 459-2884
EDW -TD -6
JOB NO. 11839 FIGURE 4
•
CHURCH & Associates, Inc.
11/19/99
Pump System Design Criteria
EM
Design Flow Rate
30.0
Distributing Valve Model (# of Zones)
none
T_MMMWMM�MMMMMMMMMMM
02—an MMMMMWUMMMK=MMMMMMMM
mmm mm b��-Rmm mml\Nmm
= M�MKN�OMMMMMMMM�
1� MMS INMM\
mmmmm mmmmm
�►v0►V�IM
Lift to Distribution Point
MMMKM MMM W M
0MMM1 MMMME
mL -MLU- MMMME
NM-Mk1 MMMMM
20.0
feet
Discharge Assembly Size
.-...-m�
1.25
Transport Line Size
2.00
inches
Pipe Class?Schedule
40
Transport Length
30
feet
Flow Meter
none
'Add-on' Head Loss
0
Friction Head Losses:
Head Loss in Transport Pipe 0.5 feet
Head Loss through Discharge Assembly 4.5 feet
Head Loss through Distributing Valve 0.0 feet
Head Loss through Flow Meter 0.0 feet
Size Pump for:
DESIGN FLOW RATE 30.0
TOTAL DYNAMIC HEAD 25.0
.. No. 11839
200
w 150
0 100
r
50
P30 15 - 6 stage
�Mmmikqlwmmmmm
MMMMM�vMMM�M
GO Hertz 115/230 Volt A
IM
MMMMM®MMONM��
EM
MOMMM MMW
'Available in 11 5V or 230V
�MMMM MMMMI
WMmmm�i
T_MMMWMM�MMMMMMMMMMM
02—an MMMMMWUMMMK=MMMMMMMM
mmm mm b��-Rmm mml\Nmm
= M�MKN�OMMMMMMMM�
1� MMS INMM\
mmmmm mmmmm
�►v0►V�IM
NOWNi. = MWMNMEWWWLW�MM
MMMMM M001qqM MMMM'
MMMMM MMMMM ft`'MMM
MMMMM MMMmm mok,�mm
MMMMMMMMMMMM1b\.MM1kMELWMMMM0
MMMMM MMMMM MM0ft
MMMMM MMMMMMMMMM.UMkN=MMMMN'
MMMKM MMM W M
0MMM1 MMMME
mL -MLU- MMMME
NM-Mk1 MMMMM
M�MMMMMMMMM�MMMMWUMMMMMI
IN MMMM--..-M�
..-.--..■.
mm�MMM..
N�MMMM-.-..-.
.-...-m�
0.
0
10 20 30 40 50
Net Discharge, GPM
0
00
E
PROFILE:
TABLE 1 - PERCOLATION TEST RESULTS
R-2, STARWOOD VILLAGE DATE OF TEST: 11-18-99
Pitkin County, Colorado
IF -4 Aoc-; finn
0 -1' Topsoil, Root Zone
1'- 8' Clay, Sandy, Very Stiff, Moist, Red/Brown
NO GROUND WATER WAS ENCOUNTERED WITHIN THE EXCAVATION
7
AVG.
INTERVAL
DEPTH TIME DEPTH DEPTH CHANGE, PERC.
HOLE
HOLE
NUMBER OF HOLE, INTERVAL, START, END, (INCHES) RATE
PERC.
(INCHES) (MINUTES) (INCHES) (INCHES) MPI
(MPI)
RATE,
17
IMPI1
7
21
30
12.00
16.50
4.50
7
1.75
17
12.75
30
16.50
19.00
2.50
12
30
30 16.00 17.00
1 1.00
30
11.50
13.50
2.00
15
14.50
15.25
0.75
30
13.50
15.50
2.00
15
15
8 24
30 11.25 13.00
1.75
17
2.50
12
30 13.00 14.75
1.75
17
12.75
13.75
30 14.75 16.00
1.25
24
30
30 16.00 17.00
1 1.00
30
30
9 26
30
10.2.5
12.75
2.50
12
30
12.75
13.75
1.00
30
30
13.75
14.50
0.75
40
30
14.50
15.25
0.75
40
40
NUMBER OF HOLES: 3
AVG PERCOLATION RATE (MPI): 28
Remarks: Holes presoaked 8 hours prior to data collection
Job No. 11839
3.08 ACRES
152 BUCHANAH DRIVE
STARWOOD SUBDIVISION
PITKIN COUNTY, COLORADO
BED A: 2 CHAMBERS X 10
CHAMBERS IN LENGTH
BED B: 2 CHAMBERS X 6
CHAMBERS IN LENGTH
BED C: 2 CHAMBERS X 5
CHAMBERS IN LENGTH
JOB NO. 11839
t
DISTRIBU-
BOX-
BUCHANAN DRIVE
-
-
r
EXISTING GRAY
WATER SYSTEM
EXISTING TANK WITH DOSING SIPHON
EXISTING 1250 -GALLON SEPTIC TANK
WITH EFFLUENT PUMPING SYSTEM
ADD ONE 2000 -GALLON SINGLE COMPARTMENT
PRE -CAST CONCRETE SEPTIC TANK
EXISTING<,f
RESIDENCE n §
NEW GRAY WATE
JC_" PVC OUTLET PIPE
AUTO COURT
`N%"% RETAINING WALL-.. _
E
RETAINING WALL
100
SCALE
1 " = 40'
I
P-4 TO BE ABANDO D {jJ
- 1 C
_ _... J
F -U _ __ �- g ...- ...... _... _..... — —
L_ — — 90��- — — 961 SF OF INFILTRATIVE AREA IN 4 GRAVELLESS BEDS
OWS AS -BUILT DRAWING WITH INFILTRATORS/CHAMBERS.
FIGURE 1
3.08 ACRES
152 BUCHANAN DRIVE
STARWOOD SUBDIVISION
PITKIN COUNTY, COLORADO
BED A: 2 CHAMBERS X II
CHAMBERS IN LENGTH
BED B: 2 CHAMBERS X 10
CHAMBERS IN LENGTH
DISTRIBUTI
BOX
BUCHANAN DRIVE r
'NEW'
DISTRIBUTION
BOX _
t
Mm
EXISTING GRAY
WATER SYSTEM
TO BE ABANDO D
..... .. ... "I','"', .... ... .. .
UTILIZE EXISTING TANK WITH ADDED
J
1
i�.
I�
EFFLUENT PUMPIMG SYSTEM
EXISTING 1250 -GALLON SEPTIC TANK
ADD ONE 2000 -GALLON SINGLE COMPARTMENT
PRE -CAST CONCRETE SEPTIC TANK
I
RETAINING WALL I
^ AUTO COURT
i
EXISTING.
kk' RESIDENCE r�-
I
NEW GRAY WATE
",4" PVC OUTLET PIPE
FIELDS TO FOLLOW
GARAGE
TOPOGRAPHIC CONTOUR
4" PVC LINE;_' r
110 I
k `+c 3 w r 'y
TO NEW'
SEPTIC TANK
L-`
NOTE:
RETAINING WALL
CLEANOUT TO BE
100 PLACED OUTSIDE
_ ROFILE PIT I --
......................_..... ..
RESIDENCE IF NOT
_ PRESENTLY EXISTING
P"
P -o D DIS BUTTON BOX - -
J
- - 90��. - -
10 MIN ADD 992 SF OF INFILTRATIVE AREA IN 3 GRAVELLESS
!-
LOCATION OF PROPOSED OWS BEDS WITH INFILTRATORS/CHAMBERS.
1 " = 40'
REVISED FIGURE 2
JOB NO. 11839
TYPICAL PLAN VIEW - N.T.S.
GRAVELLESS CHAMBER
3' BY 6.25'
BED A
6'
3'
4" SCHEDULE 35 PERFORATED
4" SCHEDULE 35 PVC I PVC PIPE SUSPENDED ACCORDING TO
OBSERVATION/VENT PIPE MANUFACTURER SPECIFICATIONS
(PIPE INSTALLED LEVEL)
TYPICAL CROSS-SECTION - N.T.S.
4" SCHEDULE 35 PVC
BSERVATION/VENT PIPE
WITH CAP
r -BACKFILL
4' MAX
0
•
•
EXTENT OF EXCAVATIO
CALCULATIONS AND SPECIFICATIONS
DESIGN CRITERIA
STRUCTURE - 4 BEDROOMS, >6000 SF
LOADING - 130 GAL/DAY/PERSON
TOTAL LOADING - 1040 GPD
PERCOLATION TEST - 28 MPI
AREA - (1.75 X Q XRT)/5 = 1926 SF
ADJUSTED EXISTING AREA = 540 SF
ADDITIONAL AREA NEEDED = 1386 SF
REDUCTION FOR USE OF CHAMBERS - 30%
TOTAL AREA - 970 SF
. 11839
1.5 -MIN.
sm
THREE TOTAL BEDS
4" SCHEDULE 35 PERFORATED
PVC PIPE HUNG ACCORDING TO
MANUFACTURER SPECIFICATIONS
GRO�NO
W
GRAVELLESS CHAMBER
3' BY 6.25'
BED SPECIFICATIONS
NUMBER OF BEDS - 3
BED A-2 CHAMBERS WIDE X 11 CHAMBERS IN LENGTH
BED B-2 CHAMBERS WIDE X 10 CHAMBERS IN LENGTH
TOTAL NUMBER OF CHAMBERS - 64 CHAMBERS
TOTAL AREA - 992 SF
DRAIN FIELD DETAILS
EFFLUENT INLET _
(1/8" PER FOOT DROP) r—
ISTRIBUTION BOX
6' IN /
EFFLUENT LINE
TO ADDITIONAL 'A'
BED
LEVEL MANIFOLD
TYPICAL DISTRIBUTION BOX - N.T.S.
3'
APPROX.-
PLAN
PPROXIPLAN
VIEW Z
I_4
OUTLET
ROX.
CONCRETE DISTRIBUTION
BOX
4" SCHEDULE 35
PVC PIPE
F -INLET
-OUTLET
INLET OUTLET
VIEW VIEW
* MINIMUM OF SEVEN OUTLETS NEEDED
TREATMENT UNIT SPECIFICATIONS
TOTAL CAPACITY - 1.75 X Q X (30 HOURS/24 HOURS) = 2275 GALLONS
RECOMMENDATION - ADD 2000 GALLON SINGLE COMPARTMENT PRE -CAST CONCRETE
SEPTIC TANK. TO BE FOLLOWED BY EXISTING 1250 GALLON SEPTIC TANK AND DOSING
TANK. ADD EFFLUENT FILTER TO OUTLET OF EXISTING 1250 GALLON SEPTIC TANK
AND ADD PUMP TO REPLACE DOSING SIPHON.
REVISED FIGURE 31
TO 8"
APPROX.
1' APPROX.
-OUTLET
INLET OUTLET
VIEW VIEW
* MINIMUM OF SEVEN OUTLETS NEEDED
TREATMENT UNIT SPECIFICATIONS
TOTAL CAPACITY - 1.75 X Q X (30 HOURS/24 HOURS) = 2275 GALLONS
RECOMMENDATION - ADD 2000 GALLON SINGLE COMPARTMENT PRE -CAST CONCRETE
SEPTIC TANK. TO BE FOLLOWED BY EXISTING 1250 GALLON SEPTIC TANK AND DOSING
TANK. ADD EFFLUENT FILTER TO OUTLET OF EXISTING 1250 GALLON SEPTIC TANK
AND ADD PUMP TO REPLACE DOSING SIPHON.
REVISED FIGURE 31
i
rw-
;r„1 associates
WS EAS' VA. S*AEET
ASPEN COIOAADOB'r, r
rE 1391 925- M
ME
1 *f M: DO16N vevm oPf'
PRWN6 PAGKABE
f -01s :P9iF71T:8ET : : :
FQ!T9:PRO6Rfrb : :
%?ZEf'4�i: PAvbpihfS :
:-:.}zan: CoN4tWWioa
A7f ei4
:Ahlbl$ :
e- v •J»,
9•:9 •:'fR Dom'
J
sARNARvMAIi
152»
STA WDDO SAIDIVI610N
M7KW cow f, cO ORAM
KEYPLAN