Loading...
HomeMy WebLinkAboutpitkin.eh.264326402011 (2013)Pitkin County Environmental k._alth Department Onsite Wastewater Treatment System (OWTS) USE PEF Permit for Continued Use of an Existing OWTS 76 Service Center Road, Aspen, CO 81611 Phone: 970-920-5070 Fax: 970-920-5374 www.aspenpitkin.com/EHNR ParcellD #: 2643-264-02-011 OWTS Use Permit #: I 0052.2013.powu Date Issued: 11/4/2013 Issued By: Bryan Daugherty Expiration Date: 11/4/14 Owner(s): I Judith Barnard and Michael Fain Property Address: 152 Buchanan Drive Legal Description: Lot R-2, Starwood Licensed Inspector: Carla Ostberg Inspection Date(s): 10/24/13 SYSTEM INFORMATION Components Type Capacity/Size Primary Treatment Unit Concrete 1 compartment tank Concrete 2 compartment tank 2000 gallons 1250 gallons Secondary Treatment Unit Absorption Area travelless Chamber Trenches 443 ftz Other System Components Pump OWTS Use Status: ® In use at the time of the inspection. ❑Not in use at the time of the inspection.* *If the OWTS was not in use at the time of the inspection, it is recommended that the system be re-evaluated when it is in use for a more accurate evaluation of the system. System Records: Permit #: 99100 Date of Issuance: 11/30/99 Date of Final Approval: 1/20/00 # of Bedrooms or fixtures served by OWTS: This system is designed for 4 bedrooms. Operational Status: The system was working properly at the time of inspection. Both tanks were in good working order with inlet and outlet tees in place. Sludge levels were checked and did not warrant pumping at this time. Pumps in the outlet of the 2nd tank were both functioning correctly and the high water alarm was functioning. The absorption area did not show any signs of failure or surfacing effluent, there were no observation ports to check for standing effluent in the chambers. Inspector Recommendations: Inspector recommends annually cleaning the effluent filter. Department Recommendations: N/A Issuance of this OWTS Use permit is based solely on the conditions observed and reported by the inspector to the Department on the date of the inspection(s) and on Department records at the time of permitting. The issuance of this permit does not constitute a guarantee, warranty, or representation by the Department that the system will operate properly or will not fail or that the system will not be subject to future enforcement action to correct non-compliant conditions. Estimated capacity of the system has been listed on the permit and we recommend that you monitor and/or meter water use to prevent overuse and possible failure. Page 1 1 Barner 'Fain 3126431W Pitkin County Environmental Health Department t g onsite Wastewater Treatment System (OWTS) USE PERMIT APPLICATION 76 Service Center Rd Aspen, CO Ml i Webette: www.a3penp1Udn.comlehnr/ Application for Continued Use of an Existing OWTS P.1 Pstool IDS (avaitabio front the Peskin County Assessors office •, r _ .4 _ •� - { f L- tP 870-920�t60 or at �s � oflLv�ktn?sa4ssor.oral: t j�QT Purpose of Use PetmkC Op>:tiTY7RAN5ACROtt ❑ Rr�tOitEl/ADDrilON Property Address' � City. State. LoL• 8lacit: FSutg: Subdlt+lslOtl: J� i Residences: Other frXluteSlUaes: Business Phone: _ �02�` ff of Wroomr. ( Email Addr Addra Ptopolty U5lret(s)': . oiI 1 Indicate Preferred Melhod of Permit Receipt Email b; ne WHWHIng Addfesa City. Slate. Zlp: a'- i -� fie tma Ph business Phone. .r4... M rnlw MsfMM Mrrtr ire OIW,Clgo Eul 11n) fTYlItl1 i1Y/N,/f/ -oMY"`�•^'/- Pamary Cottle Pe on/AppTtcsnt (K not own }: y. Pow t j�QT 'vt r ` ConlecVAppdcant tdatfng Address: City. State. Zjx eve Grp $ 3 5 EAis CeN t'hor- Business Phone: _ �02�` Fax Nom6er. Email Addr 1 Indicate Preferred Melhod of Permit Receipt Email C1 Pax El u5 Mail FaxfVumtter: rnnualy nvulnw. r �,,, - - �1}n Fern �rtt�,�ne i �iYl�tt CSC( —0 6 Y\ t g (QZ�i PLEMF ROAD BEFORE SIGNING: I oerofy that the above Infomtatlon Is complete and accurate and that t have provlded complete and accurate h formstion in all of the documents Included in my appRoallon package. I acknowledoe that thls dapattmsni may ravoko any permit 1 am Isausd ff my application In found to contutn any lnaccurate, (also, �x misleading infomnetlon. Onstersigna/8ro (fterlulrad): Dates Applka�YStgnsiultr, Date: V Please allow 3-5 business bays far processing of tis@ PermRs. IN Onsite Wastewater Treatment Systems (OWTS) Use Permit Inspection Form cou N Pitkin County Environmental Health Department 76 Service Center Rd, Aspen, CO 81611 Phone: 970-920-5070 Fax: 970-920-5374 Website: www.aspenpitkin.com/ehnr Inspection form for continued use of an existing OWTS Owner's Name: hii, y1co- Address: V\,Fj S Q r , (,-)o SZ I i,Q i t Parcel Number: �Ip U �� - �-bLj- p ;- -0! Inspection Date: k a I ZLA 1 121 Inspector's Name: Business Name: C pj �D In Phone Number _ on 0 - �jpq 5 DG q Email: ^ t r`(G ► 05 92�L ( C�Y��t�r 1, t_71`V%A Pitkin County Systems Inspector License Number: d 1 A copy of this inspection report will be remitted to Pitkin County Environmental Health Department by the Licensed Systems Inspector within 60 days of the inspection regardless of whether the system passes or fails. QUESTIONS FOR PROPERTY OWNER PRIOR TO INSPECTION: Is the home currently occupied? YES If NO, how long has the home been vacant?�U How many bedrooms are in the home? If secondary treatment is used, who is the maintenance provider? RECORDS: Were system records available from Pitkin County?ES NO If YES: Permit number: � �- Date of Final Approval: I l ad 0 # of bedrooms permitted:_ Was an as -built drawing available? YES NO Is the as -built drawing accurate? S NO NJ� 0 VVI -j rc If NO: Complete a drawing of the system on last page of this form as accurately as �1 possible. Any question marked FAIL will require correction before an OWTS Use permit is issued. SITE CONDITIONS: Proper grading, no evidence of erosion? P FAIL Improper vegetative cover? O YES Evidence of compaction such as heavy machinery or livestock? N YES Improper discharges such as straight pipes? P FAIL Evidence of high ground water? YES Snow cover present? 0 YES Page 1 TANK: Tank 1 Tank 2 Evidence of past surfacing? Tank 3 YES Tank capacity gallons 2-GjC7 gallons NO gallons Tank material (` Probing Liquid in observation port? NO YES # of compartments inches Distribution Box or ADV part of original design? ' YES NO Date of last pumping _, irl If YES, is it accessible from grade? YES ,NO Lids/risers in good condition P FAIL PASS FAIL PASS FAIL Risers to grade NO NO YES NO Riser height Riser condition/watertightness (' t — Inlet sanitary T/baffle PASS FAIL PAS FAIL PASS FAIL Outlet sanitary T/baffle PASS FAIL PASS 'A mVVAIL PASS FAIL Effluent filter (if part of design) PASS FAIL N/A,, PASS_ FAIL N/A PASS FAIL N/A Condition of tank material PASS ; FAIL PA35 FAIL PASS FAIL Tank was pumped for inspection YES NO YES NO YES NO If YES, list the pumping company If NO, when was the last pumping Scum level (1st compartment) `� inches Q" inches inches Sludge level (1st compartment) -loO inches 0' inches inches Scum level (2nd compartment) r/ inches r inches inches Sludge level (2nd compartment) 011 inches 1'' inches inches Backflow (if pumped) PASS—FAIL—P-ASS FAcc PASS FAIL Midtank baffle PASS FAIL/'—N7A PASS FAIL N/A PASS FAIL N/A Watertightness ' PASS. FAIL PASS FAIL PASS FAIL If PUMPS/DOSING SIPHONS: 2- Is a pump or dosing siphon present? YES NO j�ccn�. p5 if YES, is the pump/dosing siphon functioning properly? qPASS FAIL Does the pump/wiring/dosing siphon appear to be in good condition? FAIL f Is the high water alarm working, both visible and audible? FAIL — pao/ ' l l SECONDARY TREATMENT: Is a secondary treatment unit present? YES O UNKNOWN If YES, does the unit appear to be in good working condition? YES NO Does the owner have a current maintenance contract for the unit? YES NO UNKNOWN Maintenance Provider: Phone: If there is no maintenance contract, a contract must be in place prior to occupancy of the home. A copy of the contract must be submitted to Pitkin County Environmental Health Department. ABSORBTION AREA: Effluent surfacing? PASS FAIL Evidence of past surfacing? N YES Surface dampness? NO ` YES Excessive odors? NO YES Field location verified by observation ports or probing: Ports Probing Liquid in observation port? NO YES If YES, record depth: inches Distribution Box or ADV part of original design? ' YES NO If YES, is it accessible from grade? YES ,NO Is it level and in good condition? PASS FAIL Page 2 r t UNKNOWN C Any problems with the system that were not addressed in the inspection checklist? Please list any recommendations for the continued use of the system: Ir L u 0 D f U -S Were any repairs done as a result of this inspection? NO YES If YES, please describe the repairs. To the best of my knowledge and training, the information collected in this inspection is accurate as of nJ Z! 20 . Licensed Systems Inspector Signature: Additional Notes: Clearly label any pictures and attach them to this form. Page 3 rol 0Cn 0 0 CBO Inc. 33 Four Wheel Drive Road 0 _� V ti Carbondale, CO 81623 cell) 970-309-5259 office) 970-704-0484 `- carla.ostberg(mgmail.com October 26, 2013 Pat McAllister pdm(a)kdmlaw.net Onsite Wastewater Treatment System (OWTS) Use Permit Inspection 152 Buchanan Drive Pitkin County, Colorado Mr. McAllister, As requested, CBO Inc. performed an Onsite Wastewater Treatment System (OWTS) Use Permit inspection at 152 Buchanan Drive, Aspen, Colorado on October 24, 2013. The permit and record drawing was provided by Pitkin County Environmental Health Department (Parcel ID # 2643-26402-011). The subject OWTS consists of one 2000 -gallon, single - compartment concrete septic tank followed by one 1250 -gallon, two-compartment concrete septic tank with a duplex pump system and an Orenco® Biotube filter in the second compartment. The absorption area consists of two separate areas; one area consists of four gravelless chamber beds installed in 1999, and the other area consists of three trenches installed in 1993. The septic tanks appeared to be in good condition. There was no accumulation of scum and 8 to10- inches of sludge present in the 2000 -gallon tank. There was no accumulation of scum of sludge in the 1250 -gallon tank. Pumping at this time is not necessary. The inlet and outlet tees on the 2000 -gallon tank were not visible from the manhole lids. A camera was lowered into the septic tank and a video confirms the presence of the inlet tee. The inlet tee of the 1250 -gallon septic tank was visible from the manhole lid. Two pumps and two outlets were present in the second compartment of the 1250 -gallon septic tank. The floats were tested and the pumps appeared to be working properly. The alarm sounded when the high water float was raised. The control panel for the pumps is located in the house near access to the crawl space. The absorption areas showed no signs of saturation, and had no indication of failure. Distribution boxes noted on the drawings were not accessible from grade. Observation ports were not present. Recommendations: Clean filter annually, or as needed. This report should be submitted to the Pitkin County Environmental Health Department. The following links are the required application and application checklist. Application: http://www.aspenpitkin com/Portals/0/docs/county/Com%20Dev/EHNR/OWTS%20Use%20Permit% 20Application.pdf Application Checklist: hfp://www aspenpitkin.com/Portals/0/docs/county/Com%20Dev/EHNR/OWTS%20Use%20Perimt% 20Application%20Checklist. pdf Please call with questions. Sincerely, Carla Ostberg, MPH, REHS NAWT Certified Inspector Certification # ITC11042010 Exp. 2014 View of septic tank lids Inlet side of 2000 -gallon tank Outlet side of 2000 -gallon tank Inlet side of 12:50 -gallon tank Pump chamber with removable filter — two pump lines exit tank to two separate absorption areas. Weep holes present in both pump lines. Effluent filter prior to cleaning. This filter should be cleaned annually, or as needed. Absorption areas — no observation ports — no access to distribution boxes M �4ww ° November 3, 2013 Kathy DeWolfe Onsite Wastewater Treatment System (OWTS) File Review 152 Buchanan Pitkin County, Colorado Ms. DeWolfe, As requested, CBO Inc. performed a file review associated with the Onsite Wastewater Treatment System (OWTS) at 152 Buchanan Drive, Aspen, Colorado. The system was recently inspected and found to be in good working condition. The file was provided by Pitkin County Environmental Health Department (Parcel ID # 2643-264-02- 011). The subject OWTS consists of one 2000 -gallon, single -compartment concrete septic tank followed by one 1250 -gallon, two-compartment concrete septic tank with a duplex pump system and an Orenco® Biotube filter in the second compartment. The absorption area consists of two separate areas; one area consists of four gravelless chamber beds installed in 1999, and the other area consists of three trenches installed in 1993. It appears 1993 system (set up to handle gray water and black water separately) has three deep gravel trenches of varying lengths; the first trench 51 -feet, another 48 -feet, and the last trench 54- feet- The 1993 permit (ISDS Permit 93012) does not note the exact square footage installed. Calculations done by Church and Associates in 1999 note an "adjusted existing area" as 540 square feet. The 1999 system (ISDS Permit 99100) and as -built documentation shows the 1993 gray water system was completely abandoned and four new gravelless chamber beds installed in addition to the existing trenches for the 1999 black water system. The new chamber trenches totaled 961 square feet. The following table describes the existing system compared with requirements under Pitkin County's current Onsite Wastewater Treatment System Regulations for a 5 -bedroom residence with greater than 6000 square feet of living area. Please keep in mind new regulations will be adopted, in accordance with state law, before July 2014. Existing OWTS CBO Inc. Septic Tank Capacity 2000 -gallon, single 33 Four Wheel Drive Road e <. compartment Carbondale, CO 81623 1250 -gallon, two-compartment cell) 970-309-5259 office) 970-704-0484 with pump carla.ostberg(a)gmail.com November 3, 2013 Kathy DeWolfe Onsite Wastewater Treatment System (OWTS) File Review 152 Buchanan Pitkin County, Colorado Ms. DeWolfe, As requested, CBO Inc. performed a file review associated with the Onsite Wastewater Treatment System (OWTS) at 152 Buchanan Drive, Aspen, Colorado. The system was recently inspected and found to be in good working condition. The file was provided by Pitkin County Environmental Health Department (Parcel ID # 2643-264-02- 011). The subject OWTS consists of one 2000 -gallon, single -compartment concrete septic tank followed by one 1250 -gallon, two-compartment concrete septic tank with a duplex pump system and an Orenco® Biotube filter in the second compartment. The absorption area consists of two separate areas; one area consists of four gravelless chamber beds installed in 1999, and the other area consists of three trenches installed in 1993. It appears 1993 system (set up to handle gray water and black water separately) has three deep gravel trenches of varying lengths; the first trench 51 -feet, another 48 -feet, and the last trench 54- feet- The 1993 permit (ISDS Permit 93012) does not note the exact square footage installed. Calculations done by Church and Associates in 1999 note an "adjusted existing area" as 540 square feet. The 1999 system (ISDS Permit 99100) and as -built documentation shows the 1993 gray water system was completely abandoned and four new gravelless chamber beds installed in addition to the existing trenches for the 1999 black water system. The new chamber trenches totaled 961 square feet. The following table describes the existing system compared with requirements under Pitkin County's current Onsite Wastewater Treatment System Regulations for a 5 -bedroom residence with greater than 6000 square feet of living area. Please keep in mind new regulations will be adopted, in accordance with state law, before July 2014. Existing OWTS Minimum sizing for 5 -bedrooms Greater than 6000 sq ft living area Septic Tank Capacity 2000 -gallon, single 1875 gallons compartment 1250 -gallon, two-compartment with pump Absorption Area 540 square feet deep gravel 1556 square feet trenches (1993) • 20% reduction for dosing 961 square feet gravelless . 10% reduction for gravel chamber beds (1999) trenches and gravelless TOTAL = 1501 square feet chamber beds The existing tank sizing is sufficient to serve a 5 -bedroom residence with greater than 6000 square feet of living area under current Pitkin County Code. The absorption area is shy of current sizing requirements by less than 5%. This discrepancy may be considered negligible and would need to be approved by Pitkin County Environmental Health Department. Other treatment alternatives, such as approved secondary treatment systems, may be considered to further reduce the required square footage. Please call with questions. Sincerely, Carla Ostberg, MPH, REHS NAWT Certified Inspector Certification # ITC11042010 Exp. 2016 PHI ie0,� y 0 m m r �€ O m m 0 PHI ie0,� y 0 m i�8 a;i�ae O o A D m :i CO "Y a ^' y HIM, -104, r� m iai�i� 9 =E %'`