Loading...
HomeMy WebLinkAboutpitkin.eh.264326402012 (1973)atp43 - aU4 - o►� PITKIN COUNTY HEALTH DEPARTMENT PERMIT NUMBER 72 0 1 di I RECEIPT NUMBERy Owner - AA Phone # 7z . Address X '5Z /`i -slJP jQ Contractor Ini;!zkF' E/x cz), Phone # Address Location Legal de Number of bedrooms l Date Signature of owne , 17 Percolation test data 12— a minutes per inch Minimum recommended absorption Minimum recommended tank size Permit application valid one year from date. Application To oecome permiL, anu 1111x1 only after lower portion is completed and signed. Retain this form at the construction site. DRAWING OF SYSTEM N i` i ,1� Qyy �o G GD -s Date C Sanitarian J Section COLORADO DEPARTMENT OF HEALTH DIVISION OF ENGINEERING AND SANITATION ACT I V I T Y RE PORT Code FILE REFERENCE: Private Sewage Disposal INDIVIDUAL OR Cattell Troxel escavtor ESTABLISHMENT: ADDRESS: NARRATIVE: 12 County 57 On August 27, 1973 I made a final inspection at the Cattell property. I was not satisfied with the leaching field or the septic tank. The outlet "T" was broken on the top and should be replaced. The field was approximately 20' X 50'. This would make it 1000 sq. ft. and not 1200 sq. ft. that Troxel indicated that he would put in, due to the slow perc. rate . COL� LETTER TO FOLLOW: ( ) OTHER RECOMMENDATIONS: DATE: August 27 19z3—. REPRESENTATIVE: ES: 7 (Rev. 6-70-100) Section r COLORADO DEPARTMENT OF HEALTH DIVISION OF ENGINEERING AND SANITATION A C T I V I T Y R E P O R T FILE REFERENCE: Private Sewage Disposal INDIVIDUAL OR ESTABLISHMENT: Mary Helen Cantell and Pope ADDRESS: NARRATIVE: Starwood Code 12 County 57 I waprt with Frank Pecjack to two more building sites in Starwood. One is owned by Mary Helen Cantell. It has a sewage disposal system installed by Ron Troxel in 1973• They are building a guest house on this site, one bedroom, one bath, but no kitchen. It may be feasable to tie into the present system, given the size of the leach field and septic tank as indicated to me. The leach field is probably somewhere in the neighborhood of 1500 to 1600 square fee an the septic is lOQO gallon .6� cont ete. �'«'f?�&Z>1 at 044 We then went next door to take a look at a lot owned Mr. adn Mrs. Pope. This particular lot is located right next door to the one I looked at before, a fairly level piece of ground, a reasonably clear area in front of the building site. Preliminary investigation reveals that unless we have problems with the pert rate, a conventional septic tank, seepage bed would present no problems in functioning adequately. LETTER TO FOLLOW: ( ) OTHER RECOMMENDATIONS: DATE: 19 ES: 7 (Rev. 6-70-100) REPRESENTATIVE: DEPARTMENT OF ENVIRONMENTAL HEALTH COUNTY OF PITKIN P. 0. BOX 1025 ASPEN, COLORADO 81611 MEMO r To: Patsy Newbury, Building Inspector From: Bob Nelson, Sanitarian Date: 8/18/75 Subject: Sewage Disposal System on lot R4, Starwood, owned by Mary Cattel / ^� I -A This department has investigated the sewage disposal system in use at the above residence and find it in compliance with current Pitkin County sewage disposal regulations. Inasmuch as there is a 1000 gallon tank and 1200 square feet of absorption area, as recorded on the permit issued in 1973, this department feels that no increases in the sewage -disposal system will be required for the addition of one more bedroom, a bathroom, and a sitting room, as indicated would be added by the contractor, Frank Pecjak. The original system was designed for a two bedroom house as required by minimum standards set in standard regulations and the residence on the property right now is only one bedroom. A building permit can be issued. � r ... ��^.ae�: lCS;�t'°'r':-a= q� a`�r:.Y;t.&s':� u,::�a',>;�an^ ..: ,.�1i► /, j?C1 TEST HOLE I TEST HOLE II Y Reading Drop Time Reading Drop Time R R Vw /7 Z P7 -C PERCOLATION TEST RESULTS: HOLE I Minutes per inch (HOLE II 120 Minutes per inch Average percolation rate: Z z ( Minutes per inch Comments on soil and/or site: Address: Signature: TEST FEE $25.00, payable in Advance r 0� 141�a 1• n s4 AFFIDAVIT (Percolation Test) c3-�i, being first duly sworn upon his oatb tnder penalty of perjury, states, avers and certifies as follows: 1. That he is the person who performed the percolation tests as required on the reverse hereof. 2. That the tests were performed in accordance with the time schedules and specifications as set forth on the reverse hereof. 3. That the test results of the said percolation tests were as set forth on the reverse hereof. 4. (In paragraph 4, affiant shall insert additional statement(s) which may be properly and reasonably required by the Pitkin County Control Officer or the affiant may wish to insert.) DATED: 19� gna u e o P son Running Test STATE OF ) SS: COUNTY OF ) S BSCRIBED AND SWORN to before me this , /qday of 19-/? / My Commission Expires: o a b is 110TE: This affidavit must be returned to the Pitkin County Pollution Control Department within 24 hours of the time the percolation tests are completed (Saturdays and Sundays excepted). X PERCOLATION TEST FIELD SHEET COMPLETE IN DUPLICATE (Check person responsible for or performing tests) ( ) NAME OF OWNER /X �rT ) t ✓� L��� T� ADDRESS _. !PHONE ( ) NAME OF CONTRACTOR OR EXCAVATOR �pvt / /0 X f ADDRESS a -Qt` PHONE �D Zoeo LEGAL DESCRIPTION OF PROPERTY +'0' c �ti" A General Information & Instructions I I In addition to compliance with all other rules and regula- tions for sewage systems as promulgated by the County of Pitkin and State of Colorado, it shall be the responsibility of every property owner/installer/contractor/excavator (the person running the tests) installing a sewage system to conduct percolation tests in accordance with the specifications hereinafter set forth. Subsequent to the performance of the required test, it will be necessary for the person responsible for/or person perform- ing the tests to file, complete and under oath and penalty of perjury, the affidavit form contained on the reverse hereof. Warning is hereby given that spot checks and inspections will be performed by the Pitkin County Pollution Control Officer and his authorized agents with or without the knowledge of person perform- ing or responsible for the tests to insure compliance with the requiements hereof. Soaking is to be kerformed in the 24-hour period between .M, and �_'�lj he on. thee_ � and days of 1 - he actual pero ation tests are to be per rmed at ���-. M. and M. on , 19 At least two (2) test holes per system must be run. They should be in the area (within _=< feet) of the proposed leach- ing system and dug to the depth of the proposed system, generally 2.5 to 3 feet deep and 12 to 16 inches in diameter. The holes are to be soaked for a 24-hour period prior to running the test.