HomeMy WebLinkAboutpitkin.eh.264327400008 (2011) (CDU)rWFINUIE .,JNSITE WASTEWATER TREA .'ENT SYSTEM (OWTS) CONSTRUCTION PERMIT 0405 Castle Creek Road, Suite 10 - Aspen, CO - 81611 Phone: 970.920.5070 Fax: 970.920.5077 Permit #: 002.2011.powt Parcel ID #: 2643-274-00-008 Permit Issued: ®NEW CDU ❑REPAIR ❑REMODEL/ADDITION ❑TANK ONLY ❑FIELD ONLY ❑AMENDMENT Owner(s): Sweet Property Address: Legal Description: Size of Lot: 13 Si7P nf Buildina: ,pen Sunn 292 Sunn de Lane Lot 12, White Horse Springs Ranch Acres Detached Accessory Unit: Sq. Ft. Size of Accessory Unit: The system is designed for: CDU 1 bedrooms Designed By: Phone #: Fax #: Sopris Engineering Project #: 970-704-0311 Mailing Address: 970-704-0313 Email Address: Perc Rate: 20 Profile Hole Depth Minimum Tank Capacity: 281 gallons ®YES ❑NO 1100 detached Sq. Ft. 10218 Dated: January 10, 2011 502 Main Street, Carbondale, CO 81623 9 ft Depth to Groundwater or Bedrock: Greater than 9 ft Minimum Absorption Area: 174 sq ft (2ndary treatment) Pprmit Conditions: This OWTS Construction Permit is approved on the condition of compliance with the engineer design as submitted with the application and the specifications cited above. Changes must be approved by this Department and the engineer prior to construction. This design calls for one 1000 gallon two compartment tank with an effluent filter on the outlet tee. The fields will consist of one row of 8 Eljen in -drain units (sized using secondary treatment standards). Place 6" of concrete sand below the in -drain units and surrounding the units 18" on each side and ends. A 4" perforated PVC pipe will be placed on top of the units and filter fabric placed on top of the entire bed. 12" of clean backfill will be placed on top of the fabric. This Permit must be kept on-site during installation. The engineer must do a final inspection of the installation and submit an "as -built" letter to this Department within 30 days of the final inspection, unless a longer period of time has been agreed upon, in writing. This Department must also be called for the final inspection with a minimum of 48 hours notice. Minimum horizontal distances between components of the system and physical features shall conform to the requirements of the Pitkin County OWTS Regulation. This Permit is conditioned upon the property owner(s) providing for regular inspection, cleaning, and maintenance of the system by qualified personnel, in accordance with the manufacturer's recommendations and the requirements of the Pitkin County OWTS Regulation. Issuance of this OWTS Construction Permit does not constitute a guarantee, warranty, or representation by the Department that the system will operate properly or will not fail. THIS PERMIT IS EXPRESSLY CONDITIONED UPON COMPLIANCE WITH ALL REQUIREMENTS OF THE PITKIN COUNTY OWTS REGULATION, INCLUDING BUT NOT LIMITED TO THOSE CONDITIONS SPECIFIED ABOVE. Plans and specifications for the proposed OWTS have been reviewed and are considered satlstactory. t,ermisslon Is nereuy given to the property owner(s) to perform the work indicated in accordance with the Pitkin County OWTS Regulation. This Permit will expire 1 year from the date of issuance unless construction on the system has commenced. An "as -built" drawing must be submitted andel approved by EH before final approval of the system will be issued. Issued By: C .� C� ,, L) , , (-� Date: c3 C Expires: 2 Installer: License #: Reactiv tion Aut orized 1 c1'Z -UX k_ Final Approval Issued By: Dat New Expiration Date: E>W 6'1t�E:I1. Jan. 12. 2011 9:57AM No, 0700 P. 2 C � ONSITE WASTEWATER TREATMENT SYSTEM (OWTS) CONSTRUCTION PERMIT APPLICATION 0405 Castle Creek Road, Suite 10 • Aspen, Co -alai i Phone-, 970.MO,5070 Fax: 970.920.6077 ODU A o. P0 w Parcel 109 (available from Ilia Pitkin County Aueatora Office / 970420-0100 or at �naoseeuor.aml: 2_ S2 /yOd _08 ` Rrrpoa. at Permft: R NEW D REAUR DUE TO FAILURE ❑ REMODEynootTlON ❑ TANK ONLY ❑ FIELD ONLY /fes Lot I2 t I zjq 9kmck: 2 Filing: ubdivlelon IvHIU hbRSE SPR'IJVGs MNC44 Pltipeity ��w� � �✓.j�NN iaZ;7� Addfeaa: ar. MalIr>0 Addraaa C Hama Phone: —� ossa 5"©— 1 '�.�D Ira sire of autldlng (aquaro Q: Number of Poianaal 6a *mrr e. �y Qdo /�lklN �DuS� oVtammheo Ao0wWV 3 VB ❑ NO sir 6FARwascry uNluere realj_ 000 V O Number or Poran eadMwM In or Fixture Ual W t1le ACOlizaary Unit: C D u Wetar 8raat:p; ❑ PRIVATE WELL Q SUfx*a WATER - o SPR w J9 00MMUNM/PUBLIC WATER SY571_'M Nome of Community/PvNio Hlgtter System oppt s : aFl hoRsE SPRU6s R DSS' zcr PLEASE RF-fAB BEFORE SIGNING: I cortily that the above Inforrnallon Is oomplata and acourele end that 1 have provided eemrdete and accurate Information in oil of the documents Inelpded In my application paakage- I acknowledge Hist d"R may rwoke any permit I am Issued it m application le found to eonlatn an I ta, fa1.., ormlaleading Information, I undoWilrid that no construction mq be undurtaken on an OWIA until on OWT9 Conalrucllon Permit Itleans . 44 l /I °°W, l Reoeived by ENNR OWP f _ 'T — - Fsp pi Racdpl # Datta L REQUEST FOR REACTIVATION OF EXPIRED i OWTS CONSTRUCTION PERMIT } 76 Service Center Rd • Aspen, CO.81611 Phone: 970.9205070 Fax: 970.9205374 This form should be used for requesting reactivation of an expired [SDS or OWTS Construction Permit. If there have been any significant charges or deviations from the information submitted and accepted by this Department with regard to the expired permit, a new application cnd fee will be required. Permits issued under prior regulations may only be reactivated under limited circumstances. When a new application is required, the system requirements must conform to the current OWTS Regulation which can to found at htto.f www.asraMitkin.com� acffslde %22oartsreg•gjd . 'ermit Number for Which Reactivation is Requested: �Z .Zoll _ �oG�Jt )arcel iD# (available from the Pitkin County Assessor's Office _ )70-920-5160 or at w ew.�i inassess ,r.or g) oe4 3 e'e::7'R 'roperty Address: 29Z SvAJNYSJD6- I -AJ ,at: Black: Filing: Subdivision: t 2_ WH IrE kc;i25E ; egl`AZ5 Building Permit #: .2-011 . RQSk 'roperty Owners : Email Address: soil -67 .te6p9 t sMAJNYS I DIE C -!o l3taj.5 bis Ca 5olsA15 . AJ67' )wner's Mailing Address: city, State, Zip: Glc $AZrimO P- fissoc . QD. 847. RSP'sN, Ca_ Affil i fome Phone: Business Phone: y'rG qz3 3egS 4W ?L3 3�5� Prima Contac[ son/Applicant (if not ownerj: ! o,u Y t ,4 P 15 f4 Company: 46sn- . Contact/Applicant Mailing Address: 0 15f?t Citv State, Zip: 1qf &: C0 9t62t Cell Phone: 476 • 3143-S `7S Business Phone: 97' - Z - Z 7 Z 7 Fax Number: AjzA Email Address: PC P r pi t LCi2_=AW _ -:-SE REAL I certify that the above information is complete and accurate. I acknowledge that EHINR may revoke any permit 1 am issued if my application is found to contain any inaccurate, false, or misleading information. I understand that no construction may be undertaken on the ISDSIOViTS until the ISOS/OWTS Construction Permit is reactivated or a new permit is issued. �a: .� • Z'7 • l Z owner/Applicant Signature Date FOR OFFICE USE ONLY Received o H/NR aff: Fee & eceipt#: Date: eacdvadcn Approved eacdvadon Denied Date of Decision: y' 2 Permit #: a U 0 2,2-01 { l , OD vJ LJ' Reason Denied: Annroved Bv: Al , i PL ()C14- /6 0 A Denied Bv: C 0 Cpu OWTS DESIGN CALCULATIONS - for Pitkin Owner's Name MI . r Pcel ID # ar House Size (sq. ft.) .§, . (75 gpd or 100 gpd) 75 Number of Bedrooms in Main House Number of Offices, Libraries, Studies, Similar -sized Rooms in Main House Number of Bedrooms in Detached Caretaker unit Number of Offices, Studies, Similar -sized Rooms in Caretaker Unit (If the caretaker unit is ATTACHED, treat as if part of main house.) Average Daily Waste Flow 150 State Review Required? no Perc Rate Design Flow (Q) _ # potential bedrooms X 2 people/bedroom X gpd X 1.5 Q= 225 Minimum tank capacity 281 goons Absorption Area (=Q/5 X SQRT perc rate)(1.4 loading factor) A = 244 sq. ft. of absorption area required Absorption Area (=Q/5 X SQRT perc rate) WITH SECONDARY TREATMENT (no loading factor) A= 174 sq. ft. of absorption area required Abs. Area w/ loading factor (B25) Trench Bed Quick4 Trench Quick4 Bed Pipe and Gravel (-10%) 220 no red. 244 22 25 Dosing (-20%) 195 (-20%) 195 20 20 Chambers (-30%) 171 (-10%) 220 17 22 Max Allowable 00% 122 (-30%) 171 12 17 Secondary Treatment Abs Area w/ out loading factor (B28) Trench Bed Pipe and Gravel (-10%) 137 no red. 174 16 18 Dosing (-20%) 139 (-20%) 139 14 14 Chambers (-30%) 122(-10%) 157 12 16 Max Allowable (-50%) 87 (-30%) 122 9 12 100 SETBACK FROM WELL # of feet = 50 SETBACK FROM POND, STREAM OR IRRIGATION DITCH # of feet = 25 SETBACK FROM DRY GULCH # of feet = June 6, 2012 Scott Duryea Rudd Construction 132 Park Avenue Basalt, CO 81621 RE: New Barn Caretaker Employee Toilet Addition, Usage Feasibility Evaluation for Fixture Addition Routed to existing CDU Onsite Wastewater System (OWTS), High Mesa Ranch, Pitkin County, CO: Job No. 11140.04 Parcel No. 264511100003 Dear Scott: Sopris Engineering, LLC (SE) has reviewed the documentation associated with the existing Caretaker Dwelling unit onsite wastewater treatment system (OWTS) and the proposed employee'/2 bath to be constructed in the new barn facility on the High Mesa Ranch in Pitkin County, CO. We recommend that a new 4 -inch sewage waste pipe be installed from the new facility to the existing septic tank that currently serves the one bedroom Caretaker dwelling unit. We understand that the usage of this %2 bath will be for the care taker employee. We assume that the lavatory waste could be considered an additional bathroom to be used by the same persons using the CDU facilities. We consider this usage to be infrequent. No increased peak flows to the system are expected. The new fixture design flow of 50 gpd is based on the daily use of a single employee per the fixture flow in Table 6.28-2 of the Pitkin County OWTS regulations. However we assume that the average daily use will be approximately 15 gpd. Toilet 24.8 gpd + hand sink 8.4 gpd x peaking factor 1.5 = 50 gpd requiring 50 gpd x 125% = 62.5 gpd. The existing CDU system includes a 1000 gallon two compartment concrete septic tank that requires a design detention volume of 562 gallons for the CDU. The theoretical additional 62.5 gallons from the remote employee use toilet would require 78 gallons of tank detention capacity for a total system minimum volume of 640 gallons that is less than the 1000 gallon total tank capacity. The existing system was inspected on March 1, 2011 by All Service Septic and an inspection report along with an application for a OWTS Use Permit was sent to Pitkin County. A OWTS Use Permit (No. 0011.201 LPOWU1) was issued by the Environmental Health Department on March 10, 2011. The system was operating at the time of the inspection and no problems with the function of the system was observed and no action was recommended by the Inspector, however the County recommended that an effluent filter be installed on the outlet sanitary tee. The report and use permit indicated that the system was adequate for continued use. I inspected the system on June 6, 2012 and find that the system is adequate for continued use with the addition of the employee lavatory. The field appeared to be functioning without stress and the tank had a normal liquid level and does not need to be pumped. The CDU is only used seasonally in the summer for the ranch employee(s). I recommend that the secondary access opening be recovered and fitted with concrete risers with a traffic rated iron ring and cover. A 4" Orenco effluent filter sanitary tee assembly needs to be placed on the tank outlet. I further recommend that the inlet access opening risers be fitted with an additional 12 inch riser and an iron ring to properly seat the iron cover. The tank should be inspected annually in the spring or late fall. If the sludge level is greater than 12 inches then the tank should be pumped. The effluent filter should be inspected annually and cleaned as needed and .at.time of pumping. The -existing- field should -be checked annually and the vegetative cove needs to be maintained as in its current condition. The installation of the new service, line -from .the.lavatory shall be installed with a.minimum 3 foot depth of cover. A two way 1 502 Main Street • Suite A3 • Carbondale, CO 81623 • (970) 704-0311 • Fax (970) 704-0313 1 SopRis ENGINEERING 9 LLC civil consultants 0 0 Scott Duryea SE JobNo. 11140.04-OWTS June 6, 2012 Page 2 of 3 cleanout needs to be installed adjacent to the new barns exterior wall. An intermediate cleanout should be installed if the pipe length exceeds 100 feet. The new service pipe shall be installed in the tank through the sidewall cutout with a separate inlet sanitary tee installed in the first compartment of the septic tank. Please contact me for a pre construction coordination meeting and for a final inspection of the tank retrofit and service line installation. We recommend that an as -built survey be performed on the addition. We will provide a final inspection report and a As -Built record drawing of the improvements. If you have any questions please contact me. Sincerely, SOPRIS ENGINEERING, LLC Paul Rutledge Design Engineer 11140\OWTS\stable -Lay.doc 502 Main Street - Suite A3 - Carbondale, CO 81623 - (970) 704-0311 - Fax (970) 704-0313 SOPRIS ENGINEERING • LLC civil consultants MAIN LMNG SPACE = 991 5F. NET LIVABLE EXEMPT SPACE - 0 5F. TOTAL COUNTABLE - 992 S.F. NET LIVABLE LECsEND MAIN LIVING SPACE eFLOOR AREA CALCULATIONS A2.1 NONE L LEGEND 2 X B WOOD STUD WALL ® 2 X 6 WOOD STUD WALL 19B6A6996f99 � v � wMil CTlin urnr r S NOT FOR CONSTRUCTION Date D.- By Checked By Project No. Date Issue Ot-14-2011 PERMIT SET CARETAKER DWELLING UNIT FLOOR PLAN H^ SCAB : 1/4" = V-0" (`A MCTAIl CIJ I"1\A/CI I Inl/- I In IIT CI /l!>n ni ANI A2.1 e %M %M 10. 2010 8:34AM Ci0of Aspen Water Department WHITE HORSE SPRINGS WATER AND SANITATION DISTRICT POST OFFICE BOX 808 ASPEN COLORADO 81612 TO PITKIN COUNT' ENVIRONMENTAL HEALTH DEPT. No. 257 This letter is to verify that the water district has sufficient water supply to provide water to Block 2 LOT 12 and 12A SUNNYSIDE LANE. If any question please contact Ron Ferguson Water District Superintendent and operator in charge, at 963-3180 h c,10. 2010 8:34AM Cis oT Aspen Water Department W 1wtElle,�s� "�, No. 2579 P, 2