Loading...
HomeMy WebLinkAboutpitkin.eh.264328200002 (2002) (Main House)Permit # 02010 Type of permit Re Name of Owner Street Address Pitkin County Environmental Health Department Permit for an Individual Sewage Disposal System 0405 Castle Creek Road, Suite 10, Aspen, Colorado 81611 Phone 970-920-5070 / FAX 970-920-5077 Parcel ID # Addition Ted Koutsoubos 0060 Brush Creek Rd Property legal description Size of lot 35 Water source Private well # of potential bedrooms in 2643-282-00-002 I nt 1 Rrt ich i:rPAk Ranch acres Total square footage of the house Caretaker unit Attached Total square footage of the caretaker unit 4117 # of potential bedrooms in caretaker unit 1 Designed for what # rooms (list) House =6 BRs, Barn ='/Z bath, Storage Bldg = residential kitchen sink & two 1/2baths -Z CLJ- a qty (f s �c (v a arottrns , IV? hath , n bay n , 21f7- bLli hs Ire shy Permit information 10 K-��o Designed by High Country Engineers 923 Cooper Ave GWS 81601 Perc rate 30 Profile hole depth 15 ft Depth to groundwater or bedrock +15 ft Minimum Septic tank capacity 2770 gal minimum Minimum Absorption area 2428 sq ft r_nmmantc Septic permit approved per compliance with the engineer design and specifications dated and stamped 2/4/02. Any changes must be approved by this department and the design engineer prior to them being made. Minimum horizontal distances between components of the system and physical features shall conform to the Pitkin County ISDS regulations. Design is to add on to existing system. Add one 2000 -gallon one compartment tank in front of two existing 1500 gallon tanks for a total of 5,000 gallons. Add 32 more infiltrator units,2 rows by 16 units long, for a total of 128 units. This department does not endorse any brand of products. This permit must be kept on-site during installation. The engineer must do a final inspection of the installation and submit an as -built letter to this department. This department must also be called for an inspection with a minimum of 48 hours advanced notice. Permit approved by: Date: Plans and specifications of the proposed individual sewage disposal system have been reviewed and are considered satisfactory. Permission is hereby granted to the owner or the agent to perform the work indicated in accordance with the Pitkin County ISDS Regulation in effect at the time of issue. This permit becomes invalid 6 months from the date that the permit was issued unless system construction has commenced or an extension has been approved in writing by the Department. As -built drawings must be included with this permit before the final approval will be issued. Installer: Final inspection approval im ta �� Date: ( I oL PITKIN COM ;NVIRONMENTAL HEALTH DEPAR" =NT APPLICATION FINDIVIDUAL SEWAGE DISPOSAL >f 3TEM 0405 Castle Creek Road, Suite 10, Aspen Colorado 81611 Phone 970-920-5070/Fax 970-920-5077 Name of OWNER �� d J�vy Owner's Mailing Address�E7 /t' lG /►' f% Business Phone: t� �� Home Phone: E-mail Address: L PrimaryContact Person (all communication regarding this permit will go through this person) Name Company Contact Mailing Address .o, Business Phone: 9A 7,:�&� Cell Phone : E-mail Address: Parcel ID # (available from assessor's office at920-5160 or at www.aspen.com/assessor!) Street address of property 0 L,G, 6 's�if`'iry co c�Cti d Fax: YZA — Legal Description: Lot ,Block Filing Subdivision /J/�" j N G /GG Size of lot: acres.) Type of proposed structure: 41�// ize of bldg. envelope: ��A Total square feet of house V117 # of bedrooms in house # of offices, lofts &similar sized rooms in house &�1,14rIt Caretaker Unit: Attached (;-,) Detached ( ) Total area(sq. ft.) of caretaker unit _ # of bedrooms in caretaker unit # of offices lofts and similar size rooms of caretaker Permit is for: New Home ( ) Repair due to failure ( ) Remodel/Addition Emergency use ( ) Water: Private well ( ) Spring ( ) Stream ( ) Community/Public Water System ( ) If Name of The fee for a ISDS application is $330 for a permit that takes 6 hours or less for the department to approve. If approval takes longer than 6 hours, a rate of $65 per hour will be charged. The maximum fee is $1000. The basic fee of $330 is due at the time of application. The remainder, if any, will be due in two stages: first, at the time of issuance of the ISDS permit; second, before final approval of the ISDS permit. Application for an individual sewage disposal system is hereby submitted. I hereby certify that the above information is true and accurate and that I have provided true and accurate information on locations of all existing and proposed wells, contour intervals, buildings, property lines, ditches, slopes, waterlines, springs, suction or irrigation lines, drinking water cisterns, drain tiles, irrigation ditches, lakes, water courses, streams, floodplains, dry gulches, and existing septic systems. I hereby certify that any such features not shown on attached site map are not present. Issuance of the permit does not imply the approval of any other permit required for construction pursuant to Pitkin County codes. No construction may be undertaken until all approvals and permits have been obtained. The Aspen/Pitkin Environmental Health Department, Pitkin County and employees of these agencies will be held harmless should the individual sewage disposal system fail or malfu ction. The permit to construct is issued on information submitted by the applicant or his/her representat' es. The owner assn es full sponsibility in case of failure of the system. Signature of applicant Date 2, Received by �h Receipt # Date G:\eh\isds\isdsapp\isdsapp.doc M 12/26/01 Memo To File From: Nancy MacKenzie RE: Ted Koutsoubos, 0660 Brush Creek Rd EW Permit 00053, issued 8/2/00 and finalled on 1/09/01, was for a 5 bedroom house and a storage building with 2.5 toilets and a kitchen. The toilets and kitchen were never installed in the storage building. A half bath was installed in the Tack Building which serves two employees. An application was received on 12/26/01 for an enlarged septic system to serve a remodel on the house which adds a 6`h bedroom. High Country Engineers has re -designed the system to accommodate the 6th bedroom by adding one row of sixteen infiltrator units to the existing bed. The system dated 12/19/01 is no longer designed to accommodate the storage building. If toilets and a kitchen are installed in the storage building a new system will need to be designed for this building. rte+ ( June 7, 2002 Carla Block Pitkin County Environmental Health 0405 Castle Creek Rd., Ste. 10 Aspen, CO 81611 Re: Koutsobous ISDS — Lot 1: Brush Creek Ranch Subdivision HCE File Number 2000004.31 A Dear Carla: RECEIVED JUN I U 2002 P/TENVIRp KIN COUNTY NM,ENTAL HEALTH On May 30, 2002, High Country Engineering personnel observed the reconstruction of the ISDS for the Koutsobous property on Lot 1 of the Brush Creek Ranch Subdivision. One 2000 -gallon septic tank in series one 1500 -gallon septic tank with baffle and 128 standard Infiltrator units had been installed in a bed configuration. No backfilling had taken place. No buildings had been connected to the system and the contractor agreed to maintain a maximum cover of 36 -inches. Other than that, the installation of the system was in conformance with the intent of the design. An As -built drawing has been enclosed with this letter. If you have any questions, or need additional information, please contact us. Sincerely, HIGH COUNTRY ENG f C Roger D. Neal, P.E. Project Manager G INC. IEGfSI D. F:e'••.FO 2997 �9p�•. SSIONAL 1517 Blake Avenue, Suite 101 14 Inverness Drive East Suite D-136 Glenwood Springs, CO 81601 Englewood, CO 80112 Telephone (970) 945-8676 - Fax (970) 945-2555 Telephone (303) 925-0544 - Fax (303) 925-0547 .ice ASPEN/PITKIN ENVIRONMENTAL HEALTH DEPARTMENT ISDS DESIGN CALCULATIONS Owner's Name Parcel ID # House Size (sq. ft.) (75 gpd, 100 gpd, or 130 gpd) 100 Number of Bedrooms in Main House 6 Number of Offices, Libraries, Studies, Similar -sized Rooms in Main House / Number of Bedrooms in Detached Caretaker unit ��� Number of Offices, Studies, Similar -sized Rooms in Caretaker Unit (If the caretaker unit is ATTACHED, treat as if part of main house.) Average Daily Waste Flow 1266.4 State Review Required? no Perc Rate 30 (T) Design Flow (Q) = # potential bedrooms X 2 people/ bedroom X gpd X 1.75 Q= 2216.2 Absorption Area (=Q,/ 5 X SQRT perc rate) A = 2427.7255 sq. ft. of absorption area required 157 gravelless chamber units without reduction # of Perc Holes Required: 3 1 in every soil type? Spaced uniformly over proposed area? A maximum 30% reduction is allowed for use of deep gravel or gravelless chambered system, only if the lot size and soil conditions are optimal. If a reduction is being proposed, describe why lot size and soil conditions are optimal: A = 1699.4078 sq.ft. w/30% bed reduction 1213.86273 sq.ft. w/ 50% trench reduction 110 gravelless chamber units 78 gravelless chamber units Type of system: []Absorption trenches []Absorption bed [] Gravelless chambers []Dry well []Seepage Pit []Other (type) Minimum tank capacity 2770.25 gallons SE Ci�,FROM WELL # offeet = 197.29 SETBACK FROM PONI2,._S_TREAM OR IRRIGATION DITCH # of feet = 147.296 SETBACK FROM DRY GULCH # of feet = 122.296 Printed on Recycled Paper mr-I $2�4r,?AY 1�2 ISI -rs 3?/CINi a HiIV3H 1b1N3WN081AN3 A1NnOD Wild LOR L 7, 030 ®3ni333H rd //9 vIlk, HiIV3H 1b1N3WN081AN3 A1NnOD Wild LOR L 7, 030 ®3ni333H rd //9 vIlk,