HomeMy WebLinkAboutpitkin.eh.264328200002 (2003) (Barn)Permit # 03031 New(x ) Repair( ) Addition/Remodel to House( ) jJ -- r Pitkin County Environmental Health Department Permit for an Individual Sewage Disposal System 0405 Castle Creek Road, Suite 10, Aspen, Colorado 81611 Phone 970-920-5070 / FAX 970-920-5077 Parcel ID # 2643-282-06-001 Type of permit Name of Owner Street Address Tor! ten, +cn, ihnc ar,n Rn ich (rack, PH Property legal description Size of lot 35 acres Water source Private # of bedrooms in house Caretaker unit # of bedrooms in caretaker unit Designed for what # rooms (list) I nt 1 Ri ihriivisinn Brush Creek Ranch Total square footage of the house # of offices, lofts & similar sized rooms in house Total square footage of the caretaker unit # of offices, lofts & similar sized rooms in caretaker unit Barn — 6 horse stalls + sink/shower/toilet/washer @63.4 gpd/ 1 person Permit information Designed by High Country Engineering Mailing Address 1517 Blake Ave Suite 101 Glenwood Springs CO 81601 Perc rate 34 Profile hole depth 8 ft Depth to groundwater or bedrock Greater than 8 ft Minimum Septic tank capacity 795 gallons Minimum Absorption area 519 sq ft w/30% reduction Comments Septic permit approved per compliance with the engineer design and specifications dated June 9, 2003. Any changes must be approved by this department and the design engineer prior to them being made. Minimum horizontal distances between components of the system and physical features shall conform to the Pitkin County ISDS regulations. There must be at least a 100 foot setback between the field and the well. This system will have one 1000 -gallon two-compartment tank and 36 chamber units in a bed configuration. L� 5(0 &w c� '-[ op, I I ( 0� [K)q , This department does not endorse any brand of products. This permit must be kept on-site during installation. The engineer must do a final inspection of the installation and submit an as -built letter to this department. This department must also be called for an inspection with a minimum of 48 hours advanced notice. Permit approved by: O'U'LIOLL'n �4� Date: Plans and specifications of the proposed individual sewage disposal system have been reviewed and are considered satisfactory. Permission is hereby granted to the owner or the agent to perform the work indicated in accordance with the Pitkin County ISDS Regulation in effect at the time of issue. This permit becomes invalid 6 months from the date that the permit was issued unless system construction has commenced or an extension has been approved in writing by the Department. As -built drawings must belincluded with this permit before the final approval will be issued. Installer: (fy'JV` IA kA) Final approval: Date: �i Permit # 03008 Pitkin County Environmental Health Department Permit for an Individual Sewage Disposal System 0405 Castle Creek Road, Suite 10, Aspen, Colorado 81611 Phone 970-920-5070 / FAX 970-920-5077 Parcel ID # 2643-282-06-001 Type of permit New(x ) Repair( ) Addition/Remodel to House( ) Name of Owner Ted Koutsoubos Street Address 660 Brush Creek Rd. Property legal description _ Size of lot 35 acres Water source Private Well # of bedrooms in house # of offices, lofts & s;*1 Caretaker unit Total square footage of the caret, # of bedrooms in caretaker unit # of offices, lofts & Designed for what # rooms (list) Barn — 4 horse Malls, sink, sh Lot 1. Subdivision Brush Creek Ranch Total square footage of the house Per N nformatidn Designed by High Country Engineering Mailing Address 1517 Blake Ave., Suite 101, Glenwoodrings, CO Perc rate 34 Profile hole depth 8 ft Depth to groun( Minimum Septic tank capacity 577 gallons Minimum A 1 \ Comments/ Septic permit approved per complia with th engineer de gn and changes must be approved by this d\;artment d the des' n engin( in house rooms in Caretaker unit and wasfy6'r 1 or bedrock on area Greater than 8 ft 376 sq ft w/30% reduction ecifications dated March 4, 2003. Any prior to them being made. Minimum horizontal distanc s between co i ents of t e system and physical features shall conform to the Pitkin County ISDS regulations. Vere must be at least a 10 foot set ack between the field and the well. Confirm location of waterline. If it is kloser than 25 feet from a field, fmust be encased. This system will have ond' QONgallon two -co and 25 chamber units in a bed configuration. This department does not end' any brand produc . This permit must be kept on-site during installation. The engineer must do a final inspection of th installa ' n and submit an as -built letter to this department. This department must also be called for an insp tion wit a minimum of 48 hours advanced notice. Permit approved by: Date: 1 Plans and specifications of the proposid individu I sewage disposal system have been reviewed and are considered satisfactory. Permission is hereby granted tot owner or the agent to perform the work indicated in accordance with the Pitkin County ISDS Regulation in effect at the time of issue. This permit becomes invalid 6 months from the date that the permit was issued unless system construction has commenced or an extension has been approved in writing by the Department. As -built drawings must be included with this permit before the final approval will be issued. Installer: Final approval: Date: PITKIN COUNTY ENVIRONMENTAL HEALTH DEPARTMENT APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM 0405 Castle Creek Road, Suite 10, Aspen Colorado 81611 Phone 970-920-5070/Fax 970-920-5077 Name of OWNER U 4 V $a Owner's Mailing Address Citv, State, Zip fl Business Phone: 2� X70 Z Home Phone: Q — 0 E-mail Address: Primary Contact Person (all communication regarding this permit will go through this person) Name V Company Contact Mailing Address M City, State, Zip Business Phone Cell Phone: Fax : —% Z E-mail Address: -- Parcel ID #( available from assessor's office at 920-5160or at www.aspen.com/assessors Street address of property 0W 00 Y-Sr0 N P_� Legal Description: Lot _ ,Block Filing Subdivision Size of lot: :; 5 - acres. Type of proposed structure: Total square feet of house !a5�x� # of bedrooms (potential) in house Caretaker Unit: Attached( ) Detached ( Total area(sq. ft.) of caretaker unit # of bedrooms (potential) in caretaker unit Permit is for: New Home (/) Repair due to failure ( ) Remodel/Addition ( ) Emergency use ( ) Water: Private well (/ ) Spring ( ) Stream ( ) Community/Public Water System ( ) If community system: Name of system The fee for a ISDS application is $330 for a permit that takes 6 hours or less for the department to approve. If approval takes longer than 6 hours, a rate of $65 per hour will be charged. The maximum fee is $1000. The basic fee of $330 is due at the time of application. The remainder, if any, will be due in two stages: first, at the time of issuance of the ISDS permit; second, before final approval of the ISDS permit. Application for an individual sewage disposal system is hereby submitted. I hereby certify that the above information is true and accurate and that I have provided true and accurate information on locations of all existing and proposed wells, contour intervals, buildings, property lines, ditches, slopes, waterlines, springs, suction or irrigation lines, drinking water cisterns, drain tiles, irrigation ditches, lakes, water courses, streams, floodplains, dry gulches, and existing septic systems. I hereby certify that any such features not shown on attached site map are not present. Issuance of the permit does not imply the approval of any other permit required for construction pursuant to Pitkin County codes. No construction may be undertaken until all approvals and permits have been obtained. The Aspen/Pitkin Environmental Health Department, Pitkin County and employees of these agencies will be held harmless should the individual sewage disposal system fail or malfunction. The permit to construct is issued on information submitted by the applicant or his/her representatives The.o ner assumes full responsibility in case of failure of the system. Signature of applicant Date -� Received by Receipt # �} 3 Date a- 03 G:lisdsusdsappMsdsapp.doc ���v3 m >✓ CIVIL ENGINEERING December 21, 2004 Carla Block Pitkin County Environmental Health 0405 Castle Creek Road, Ste 10 Aspen, CO 81611 Re: Koutsoubos ISDS — Lotl, Brush Creek Ranch Subdivision HCE Project Number 200004.31A Dear Carla: LAND SURVEYING The following letter is to confirm the engineer's inspection of the revised septic system of the Koutsoubos residence at Lot 1, Brush Creek Ranch Subdivision. The design included a 1,000 gallon septic tank and 36 infiltrator units. A 1,500 gallon septic tank has been installed, and the 36 infiltrator units have been changed to 54 Quick 4 standard chamber infiltrator units. The 54 units have been installed with 6 rows with 9 units each, which is sufficient with the original design's effective area. The inspection wells and manifolds have been installed per plan. The effluent filter is on site and is ready to be installed by the contractor. With the above noted changes, the system has been completed with the intent of the original design. If you have any questions, or need additional information, please contact us. Sincerely, HIGH .E. RECD A1. INC. RECEIVED DEC 2 3 2004 TYEt 'IN ENVWf, r; 1517 Blake Avenue, Suite 101 14 Inverness Drive East, Suite F-120 Glenwood Springs, CO 81601 Englewood, CO 80112 970.945.8676 phone 303.925.0544 phone 970.945.2555 fax www.hceng.com 303.925.0547 fax PITKIN ENVIRO"MENTAL HEALTH DEPARTMEN T4 ISDS DESIGN CALCULATIONS Owner's Name 7 Parcel ID # House Size (sq. ft.) (75 gpd, 100 gpd, or 130 gpd) Number of BedroomsMam House Number of Offices, Libraries, Studies, Similar -sized Rooms in Main House Number of Bedrooms in Detached Caretaker unit Number of Offices, Studies, Similar -sized Rooms in Caretaker Unit (If the caretaker unit is ATTACHED, treat as if part of main house.) Average Daily Waste Flow 0 State Review Required? no Perc Rate (T) Design Flow (Q) = # potential bedrooms X 2 people/bedroom X gpd X 1.75 Q= 0 Minimum tank capacity 0 gallons Absorption Area (=Q/ 5 X SQRT perc rate) A = 742 sq. ft. of absorption area required 48 gravelless chamber units without reduction # of Perc Holes Required: 3 1 in every soil type? Spaced uniformly over proposed area? A maximum: 50% only if the lot size and soil conditions are optimal. If a reduction is being proposed, describe why lot size and soil conditions are optimal: QUICK 4 9_8UQ ICK 4 9.2 A = 371 sq.ft. with 50% reductionTRENCHES 519.4 sq ft 30% reduction BED 38 gravelless chamber units with reduction 56 chamber units with reduc. Type of system: []Absorption trenches []Absorption bed [] Gravelless chambers []Dry well []Seepage Pit []Other (type) SETBACK FROM WELL # of feet = 100 SETBACK FROM POND, STREAM OR IRRIGATION DITCH # of feet = 50 SETBACK FROM DRY GULCH # of feet = 25 To: Robert Omoth / Ted Koutsobos From: Erena Miller Fax: 923-5311 Pages: 2 (Including cover sheet) Phone: Date: 6/7/04 Re: Septic Permit cc: High Country Engineering Hi Robert, Nancy MacKenzie has extended your Septic Permit for a year expiring 6/17/05 — please see following. Kind Regards, Phone 970-920-5070 Fax 970-920-5077 0405 Castle Creek Road, Aspen CO 81611 UO June 2, 2004 Mr Ted Koutsoubos 415 E. Hyman Ave #206 Aspen, Co 81611 Re: Parcel ID #2643-282-06-001 Property Address: 660 Brush Creek Rd - Barn Dear Mr Koutsoubos: In reviewing our files, we found that a final inspection of your Barn for an Individual Sewage Disposal System (ISDS) permit was never requested for the above property. If this project was completed, it is important that you contact our office to schedule an inspection. If the project was not completed or was put on hold, please let us know that as well. Please respond within 30 days of receiving this letter. Please contact me at (970) 920-5070 with any questions. Thank you in advance for advising us of the status of the project. Sincerely, Erena Miller Pitkin County Environmental Health cc: High Country Engineering , FEB -13-2003 15:40 H—P GEOTECH G w4w V � MNeMoCh HEPWORTH-PAWLAK GEOTECHNICAL October 3 , 2002 Ted Koutsoubos 415 East Lyman, #206 Aspen, Colorado 81611 Hepworth•1'�;,,- Geotechnical, Inc. 50'0 Cuunty 'il 154 Gleawood Springs, Colurado 81661. Plhonc: 970.945.7988 Far, 970-945-$454 ern;'il: hp;eaG3'lipgeotech.com Job No. 100 350 Subject: Percolation Testing, Proposed Septic Disposal System, Horse Barn, Lot 1, Brush Creek Ranch, 0660 Brush Creek Road, Pitkin County, Colorado. Dear Mr. I(outsoubos: As requested, Hepworth - Pawlak Geotechnical, Inc., performed percolation testing at the subject site. We previously conducted a subsoil study and percolation test for the residence and tack barn and presented our findings in a report dated July 31, 2000, Job No. 100 550. A profile pit and three shallow backhoe pits were excavated on October 23, 2002 at the locations shown on Fia. 1. The test holes (nominal 1.2 inch diameter by 12 inch deep) were hand dug at the bottom of shallow backhoe pits and were soaked with water one day prior to testing. The subsoils exposed in the percolation holes are similar to those exposed in the Profile Pit and consist of about 1/2 foot of topsoil overlying sandy clay with shale fragments to the pit depth of 8 feet. No free water was observed in the pit and the �... soils were slightly moist to moist. Percolation testing was conducted on October 24, 2002, by a representative of Hepworth - Pawlak Geotechnical, Inc. The percolation test results are summarized on Table I. The percolation test results indicate an infilta•ation rate between 26 and 45 minutes per inch with an average of 34 minutes per inch. Based on the subsurface conditions encountered and the percolation test results, the tested area should be suitable for a conventional infiltration septic disposal system. Pitkin County requires that the system be designed by a registered professional engineer. If you have any questions or need further assistance, please call our office. Sincerely, HEPWOR'l; H - PAWLAK GEOTECHNICAL, INC. Jordy Z. Adamson, Jr., P.E. Rev. By: DEH JZA/ksw attachments cc: High Country Engineering - Attn: Deric Walter Parker 303-841.7119 • Colorado Springs 719-633-5562 9 Silverrhome 970-468-1989 FEB -19-2003 15:40 H -P GEOTECH J� r� 50 40 / L 30 / \ l 20 P.03/04 40 30 / 20 PROPOSED SEPTIC SYSTEM `( IOCAl10I\! "4 / P 2 PROFILE PIT I P� TACK ea�ry WELL O I APPROXIMATE SCALE 1" = 30' 100 550 HEPWJORTH—PAWL-AK ILOCATION OF PERCOLATION TEST HOLES Fig. 1 GEOTECHNICAL, INC. FEB -19-2003 15.40 H -P GEOTECH P.04/04 HI`s ..,ORTH-PAWLAK GEOTECHNICAL, 1k-..;. TABLE I PERCOLATION TEST RESULTS JOB NO. 100 550 HOLE NO, HOLE DEPTH (INCHES) LENGTH OF INTERVAL (MIN) WATER DEPTH AT START OF INTERVAL (INCHES) WATER DEPTH AT END OF INTERVAL (INCHES) DROP IN WATER LEVEL (INCHES) AVERAGE PERCOLATION RATE (MIN./INCH) P-1 42 15 7 6 1 45 g 5 1 5 41/2 1/2 4 112 4 114 1/4 41/4 31/2 3/4 31/2 3 114 1/4 3 114 3 114 3 21/2 112 P-2 43 15 71/4 61/4 1 26 61/4 5 112 3/4 5 112 43/4 314 43/4 4 3/4 4 3 1 3 21/2 1/2 21/2 1 314 314 13/4 11/4 112 P.3 41 15 9 8 1 30 8 7 1 7 61/4 3/4 61/4 51/2 3/4 5 112 4 314 3/4 43/4 41/4 1/2 4 114 3 314 1/2 33 1A 3 1/4 1/2 Note: Percolation test holes were hand dug in the bottom of backhoe pits and soaked on October 23, 2002. Percolation tests were conducted on October 24, 2002. The average percolation rates were based on the last three readings of each test. TOTAL P.04 FEB -21-03 FRI 10:39 AM HIGH COUNTRY ENGINEERING �L�C7U/vriPJ i-�►71 NEED/NG February 21, 2 03 Carla Block via fax: 920-5077 Pitkin County Environmental Health 0405 Castle Creek Rd., Ste. 10 Aspen, CO 81611 FAX NO. 970 9 2555 P. 01 Re: Koutsoubos ISDS — Lot 1: Brush Creek Ranch Subdivision HCE File Number 2000004.31A Carla: This tetter is regarding the Individual Sewage Disposal System for the proposed Koutsoubos barn. These recommendations are based on additional percolation testing information indicating an average percolation rate of 34 minutes per inch verses the original estimated rate of 30 minutes per inch. I understand that this ISDS will serve a horse barn with 4 horse stalls and sink/shower/toilet/washer facilities for one person. Based on this information, the estimated average wastewater flow would be 263.4 gallons per day. The design flow, per regulation, is 1.75 times the average, or 460.3 gallons per day. The required standard absorption area (based on 34 minutes per inch) is 536.7 square feet, less 30% for using `Biodiffuser" or "Infiltrator" units in a bed configuration would give 375.8 square feet. At 15.5 square feet per unit, 25 units would be required. The minimum size of septic tank required is 576 gallons, however, a 1000 -gallon tank is the smallest usually available. Cleanouts should be installed at all bends leading from the barn into the septic tank. Separation between the absorption field and the existing well must be maintained at 100 -feet or more. If you have any question or comments, please feel free to contact me at (970) 945-8676 x 140. Sincerely, HIGH COUNTRY ENGINEERING, INC. Deric J. Walter, P.E. ' �- Project Engineer 1517 Blake Avenue, Suite 101 14 Inverness Drive East Suite D-136 Glenwood Springs, CO 81601 Englewood, CO 80112 Telephone (970) 945.8676 - Fax (470) 945-2555 Telephone (303) 925.0544 . Fax (303) 925-0547 �d„r}SOI� IU us CJ �CtV' � ft /ir it !i •� j' / f` � !` /i / ;/' I ! � r%• r, //`' r/'•r �� r'/ ! r ?/•, , , ! .' !` !! r J J• ,` r I - r it i' I I r / f/ '' ! i` i/ / ii j lig - r : / !; •I _'! V .i N t', r WWW -4 i N f i j !/ /f i' • i' //!/ r j \ ` \'• r r 4Z" f•% / ' ; - ! n % : ! i/ it '\\•\ •`., `\\ , ( e i / �/ ! r! ! rl !' fir !! ,!! fi!J! .'/J/r'r r rr - -`,` ` ', r a \\\♦J r• r'_ // f'/ + '.,� level 14' ? i JI J�'• r r l fr - j•' f ,' , / r _ . r: t, `• i .,\ S / \\\•' r�\\ �e VjdL 19" CP tJ 1 /• 1 /i ! � �r ri' r i' ` � •.' .'�,' A_ \`C''' � , ', !i f � / it / / ,� �j rl 1O' `' ..'` •. /r' r \ r ,!� ,\ / Jt 1' ,! /// t , / ,,�� i � m Y7 I wyz m 1 r f , i � - • r• i /, / \ �'� , `\ � \ •/ � , � , !' W Ica E. It ,:. ! ,y S .1 1 ! \'` •. -'. ' ` rr' '� .' 1 1 18' 1 `• Ad ! !/ f I i F 9 t ( '1 .••1 � t t ! .t �Vp \\ � \, %' 'Y•- �,• it "'/ , r : i r; r 1 /•. , s ! ! 1 •9 1 i •'. i i .t\\l,./ \\ ' l r c� ``�� \ --- ,;• �,' WATER LINECK r�' ,r ;i ? , ' ; `'` `� •/ i:i" / TELEPHONE LINE 0 \ \`•\ \ \ `\ / l �`.;< ` '`\ `' \\ '� • POWER LINE ` `°;.ASSN EL=7619`-8' \\ v GAS LINE \ / level 16' OAD EDGE BMW ATB -1.0 .!j it �! /1 ; J• %!_�/� '�'tc------�-- \ / � ! - GROUND LEVEL LOFT LEVEL m InI am m i ami U O v0 w z { �o P4 W o�N I O O 1 Fo s �m a � at mm IwM�w■ foam f I ..M nnr :i, teoo saasr. ATB -2.1 10 i •-��— i `�_ •���� --��_' -__• -tom IT t i -�} r I :,I pensm L, jr i= ROOF PLAN UPPER LOFT LEVEL >2 6 it WF N BARN DDDRS - TR]DD /A,\ PANTED - ON QMC , DOOR 7RACK R/ LOCK PEEL CAD FOCED MASS RRmOMS - MMM TO MATCK EXm7m HISTOMC METS HOUSE. TYP. I I L-----------------------_--_� EAST ELEVATION Her LOPr L_ PEEL CAD AMM M WIS - OHM TO MAWH EXISTNC J MSTORIC MDS HOUSE, TM PET1 MAD DOUBF HUNG NO= - OHM TO MATCH EX1SiN0 HISTQMC RQS HOUSE, TV. BOM SHUTTERS - PANTED WPE TO MATCH EASIM HMMC VES HOIAE. M. TS. - lootiv N%MW um 1ESTEIW RED CEW 9MNQES TO NAM COSTM HISTORIC Nm HOUSE, TV. MFSTEIW RED UMM - SMOOTH TX TMI - PADR *HTE TO MATCH MGM MSTOMC Mos HOUSE, TP. IESTERN RED CEDAR DE1f M SDNC r PEVEM - PMR RED TO MATCH EM"N6 HISTORIC MELS HOUSE. TYP. II I I �L—-----------------------�-------� SOUTH ELEVATION 6p4w Leve ✓vir si, sw ssssr. ATB -3.1 ATB-4.1 ANN 1 , 3 svzzr AW -20 I '' j , I a ! r � � ! ! � E E ! I r // / � ✓ l ,E { 1 E E ! -- f /� ✓ ✓ r / % - / //�/ f♦ / r / f / J / j t 1 l f IXIlly } if 69� r E f f ✓ jJf/f'�/ r / r • f (�Q jj// I J//// j'� , E E J s / r ✓ f j' 1 ;' �; � ,,r J / f jj'fi ✓t f , J �/ t S / � t i t � I / � / � � J �!` `e, ,.%' ,/ � f `' / ` w f i J�✓Yr � l � � t , f/ ! ,j I , .Jj ' ✓' / � r .' � r i ( y � �,1 t, � '' 4j� rf Lj'� Ljl� r'" { r r j✓% J J / ji. rr �' /r ! i' F I �_ / ,00 ✓'rr / ,✓f 1 1 j � e /" r j� er"" I /� "'� ✓' �''r ,%' �r1� �. `d 3/ �.i f 'Jr / l / / �� ✓ / r / / / / r 00, f / GJ 1 / 1 _ ,�✓ ✓✓ /`,"' • FLOODPLAIN DELINEATED ✓ , r ' / J'✓ i \ _ �J' , j, � � %,, � , ,., �``� • ,,. f � � � BY OTHER 4"0 PVC 10 j r r j,f I' f Q `� '� � �� SEWER (TYP .) G,�. � 1 f _ j�� iNST L 1500—GAL, J j I/ / SEP TANK (MIN .) �.I �� ' , i � � �1 f j � ��� � � t � � � � � r�I' ,rte"�,r A, ^^V V,` �Y' � 'd� � j `^V t �r' �''�r.-- __ _ _ _..—......•—•—.. ,�� 1 1 / IN TALL CLEANOUT E j tiS 1�V ( ,,_, �N � . f j v. ,, �,,,, a,,� , /', � ��\�, .�, '` t, \`•. '�''� ,`�``�,` /' � til � \i; �, ,V ,,,,�j, k� ..- �V �' ~ t EXISTING WATERLINE_ I ..� ~� ,:. ,�, _ _ _ �; l 1 t r "'• .+'".. e' if j ?rte / %r r,.•'.r _ . .. + t Zx ! , / ,/ � ___- % ,, /moi' � j •�� ,r �,%�/ ,% .--- �''J //' ,•- /,'d'r � �\✓ / ',I' ' ✓! ' J( ',�, l r' ',r ' J j j��/✓'r �-,r' /j r— NATURAL BACKFILL j� NATURAL GROUND / BED BOTTOM LEVEL AND ROUGHENED BED CROSS SECTIO( N.T.S, 0 INFILTRATOR UNIT (TYP.) 12" MIN, COVER 48" MAX. COVER GRAPHIC SCALE 30 0 15 30 60 ( IN FEET ) 1 inch = 30 ft. 4" 0 SOLID PIPE —SIDES / ROt�GHENE) IPI C REMOVABLE CAP CAP SLOTTED FOR VENT 120 - CUT HOLE IN TOP OF INFILTRATOR UNIT FOR INSTALLATION OF INSPECTION WELL PIPE . 17-7 12" 0 0 -•-- 36" INSPECTION WELL DETAIL N.T.S. PVC CAP FINISH GRADE ------ —\ 4" COUPLIN 4" SEWER I 4" PVC WYE F CLEAN OUT ASSEMBLY RISER 45' SWEEP BEND FEWER CLEAN OUT DETAIL N. T. S. FROM SEPTIC Z TANK GRAPHIC SCALE 30 0 15 30 60 ( IN FEET ) 1 inch = 30 ft. 4" 0 SOLID PIPE —SIDES / ROt�GHENE) IPI C REMOVABLE CAP CAP SLOTTED FOR VENT 120 - CUT HOLE IN TOP OF INFILTRATOR UNIT FOR INSTALLATION OF INSPECTION WELL PIPE . 17-7 12" 0 0 -•-- 36" INSPECTION WELL DETAIL N.T.S. PVC CAP FINISH GRADE ------ —\ 4" COUPLIN 4" SEWER I 4" PVC WYE F CLEAN OUT ASSEMBLY RISER 45' SWEEP BEND FEWER CLEAN OUT DETAIL N. T. S. BED PLAN VIEW N.T.S. DISTRIBUTION LATERAL (BOTH ENDS) INSPECTION WELL ( TYP. ) r'„ �X � "� � � i,� }' �',� a ' � � �'��,x'' � m�„g�" yJ ! i �� s Y ^ � �.�"•� '}'r* b �dA � h 3. r . r w '^„..a 'r `� Q � a +� a•4 s r +`^. �` � a � : � `tk ���"" C � �i �^�. '� ' a { 42 k- ' k, { ik•r�.:z y ,I.re y 4 * ¢ 4 ,L ' =3-�`a yi} �S *s^ o cr._y-^ PS�.. � >d, YC *"p^ {' a .�d d Itd" y� s r h ? x, '#t'� d, A gt4IF ,"gid r� i «Zt� Z."e1a-"r F W t riG� t -i vf 17 ^fM wR. tR �. 4 4 C' fr•"4 a �,.K �. �� b r�.' VICINITY MAP SCALE: 1"=2000' (�$ 1. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE PITKIN COUNTY REGULATIONS OF INDIVIDUAL SEWAGE DISPOSAL SYSTEMS, EVEN THOUGH ALL SUCH REQUIREMENTS ARE NOT SPECIFICALLY NOTED ON THE DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SUCH SPECIFIC DETAILS AS ARE REFERRED TO IN THE ABOVE MENTIONED REGULATIONS. 2. FLOW FOR BED: 6 HORSE STALLS * 50 GALLONS/HORSE/DAY PLUS SINK/SHOWER/TOILET/WASHER @ 63.4 GPD FOR ONE PERSON IS 363.4 GPD = AVERAGE DAILY FLOW. DESIGN = 1.75* AVERAGE = 636 GPD (Q) SEPTIC TANK: MINIMUM TOTAL TANK SIZE: 636 GPD* 1 DAY/24 HRS * 30 HRS = 795 GPD INSTALL ONE 1000—GALLON SEPTIC TANK WITH BAFFLE AND INSTALL AN EFFLUENT FILTER IN THE SEPTIC TANK OUTLET. STANDARD ABSORPTION AREA: A = Q J_t Q=MAXIMUM FLOW 5 t=PERCOLATION RATE = 34 min./in. = 636 J3_4 = 742 SF 5 USE OF QUICK 4 STANDARD CHAMBER INFILTRATOR UNITS IN BED CONFIGURATION: 309 REDUCTION— (742 S.F,*0,70) @ 9.87 S.F./UNIT, 53 UNITS ARE REQUIRED. INSTALL 54 UNITS IN A 6x9 BED CONFIGURATION. * QUICK 4 CHAMBERS: EFFECTIVE AREA = 9.87 S.F. * QUICK 4 CHAMBERS: EFFECTIVE LENGTH = 48", WIDTH = 34" 3. CLEAN OUTS ARE REQUIRED AT ALL BENDS AND AT LEAST EVERY 100 FEET ALONG THE SEWER, 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING ALL WATER TIGHT COMPONENTS, PRIOR TO THE ABSORPTION AREA, TO PREVENT INFILTRATION. 5. TOPSOIL COVER MAY BE VARIED (WITH 1 FOOT MINIMUM) TO ALLOW LANDSCAPING, 6. INSTALL RISERS AS NECESSARY TO BRING ALL ACCESS POINTS TO WITHIN ONE—HALF FOOT OF FINAL GRADE. 7. LOCATIONS OF ALL COMPONENTS MAY BE VARIED AS NECESSARY AS LONG AS ALL MINIMUM DISTANCES AND SLOPES MEET THOSE REQUIRED. 8. PROVIDE POSITIVE DRAINAGE OF SURFACE WATER AWAY FROM ABSORPTION FIELD AREA USING DRAINAGE SWALES AS NECESSARY. 9. SOILS AND PERCOLATION INFORMATION FROM INFORMATION PROVIDED BY H,P GEOTECH, INC., JOB NO. 100 550. 10. THIS DRAWING DOES NOT CONSTITUTE AN ISDS PERMIT. PERMIT MUST BE OBTAINED FROM APPROPRIATE CITY OR COUNTY OFFICIALS. ENGINEER MUST OBSERVE CONSTRUCTED SYSTEM BEFORE BACKFILL AND PROVIDE REPORT TO COUNTY, 11. THIS SYSTEM IS SIZED FOR TYPICAL DOMESTIC WASTES ONLY. BACKWASH OR FLUSHING FLOWS FOR REVERSE OSMOSIS UNITS OR WATER SOFTENERS OR FILTERS SHOULD NOT BE INTRODUCED INTO THIS SYSTEM. 12. SITE PLAN INFORMATION FROM JEFF TUTTLE, SEPTEMBER, 2002, 13. INSTALL BLUEBOARD INSULATION OVER SEWER PIPE WHEREVER DEPTH IS LESS THAN 5.0 FEET. 14. THE ENGINEER SHALL BE CONTACTED FOR SITE INSPECTION PRIOR TO BACKFILLING OF SYSTEM COMPONENTS. 15. DESIGN OF ABSORPTION BED BASED ON SOIL PROFILE INDICATING 1' OF TOPSOIL OVERLYING SILTY CLAY WITH SHALE FRAGMENTS TO A PROFILE DEPTH OF 14 FEET (EXISTING FIELD). GENERAL ABSORPTION BED NOTES 1. ABSORPTION LATERALS SHALL NOT EXCEED 100 FEET IN LENGTH. 2. THE BOTTOM OF THE ABSORPTION BED SHALL BE LEVEL. 3. DRAINAGE DITCHES ARE TO BE PROVIDED ABOVE AND AROUND BED, AS NECESSARY, TO PREVENT SURFACE RUNOFF FROM ENTERING ABSORPTION AREA. 4, BED LATERALS SHALL FOLLOW CONTOURS. 5. INSTALL INFILTRATOR IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. 6, BED BOTTOM AND SIDEWALLS MUST BE RAKED TO REMOVE SOIL SMEARS INCURRED DURING EXCAVATION. 7, NO EXCAVATION OF ABSORPTION FIELD IS TO BE DONE DURING WET WEATHER AND USE OF RUBBER TIRE VEHICLES OVER ABSORPTION AREA IS PROHIBITED. RECORD DRAWING DECEMBER 1 b, 2004 s Z �3 _ 0 in • N �o J z • Z WVcqON, 0)o O Z W m co O SO \ Z (/'� • Z W 0 Wz W • VO � = Of z �Cl) I W Co F- 5 r • Z © J Q w BED PLAN VIEW N.T.S. DISTRIBUTION LATERAL (BOTH ENDS) INSPECTION WELL ( TYP. ) r'„ �X � "� � � i,� }' �',� a ' � � �'��,x'' � m�„g�" yJ ! i �� s Y ^ � �.�"•� '}'r* b �dA � h 3. r . r w '^„..a 'r `� Q � a +� a•4 s r +`^. �` � a � : � `tk ���"" C � �i �^�. '� ' a { 42 k- ' k, { ik•r�.:z y ,I.re y 4 * ¢ 4 ,L ' =3-�`a yi} �S *s^ o cr._y-^ PS�.. � >d, YC *"p^ {' a .�d d Itd" y� s r h ? x, '#t'� d, A gt4IF ,"gid r� i «Zt� Z."e1a-"r F W t riG� t -i vf 17 ^fM wR. tR �. 4 4 C' fr•"4 a �,.K �. �� b r�.' VICINITY MAP SCALE: 1"=2000' (�$ 1. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE PITKIN COUNTY REGULATIONS OF INDIVIDUAL SEWAGE DISPOSAL SYSTEMS, EVEN THOUGH ALL SUCH REQUIREMENTS ARE NOT SPECIFICALLY NOTED ON THE DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SUCH SPECIFIC DETAILS AS ARE REFERRED TO IN THE ABOVE MENTIONED REGULATIONS. 2. FLOW FOR BED: 6 HORSE STALLS * 50 GALLONS/HORSE/DAY PLUS SINK/SHOWER/TOILET/WASHER @ 63.4 GPD FOR ONE PERSON IS 363.4 GPD = AVERAGE DAILY FLOW. DESIGN = 1.75* AVERAGE = 636 GPD (Q) SEPTIC TANK: MINIMUM TOTAL TANK SIZE: 636 GPD* 1 DAY/24 HRS * 30 HRS = 795 GPD INSTALL ONE 1000—GALLON SEPTIC TANK WITH BAFFLE AND INSTALL AN EFFLUENT FILTER IN THE SEPTIC TANK OUTLET. STANDARD ABSORPTION AREA: A = Q J_t Q=MAXIMUM FLOW 5 t=PERCOLATION RATE = 34 min./in. = 636 J3_4 = 742 SF 5 USE OF QUICK 4 STANDARD CHAMBER INFILTRATOR UNITS IN BED CONFIGURATION: 309 REDUCTION— (742 S.F,*0,70) @ 9.87 S.F./UNIT, 53 UNITS ARE REQUIRED. INSTALL 54 UNITS IN A 6x9 BED CONFIGURATION. * QUICK 4 CHAMBERS: EFFECTIVE AREA = 9.87 S.F. * QUICK 4 CHAMBERS: EFFECTIVE LENGTH = 48", WIDTH = 34" 3. CLEAN OUTS ARE REQUIRED AT ALL BENDS AND AT LEAST EVERY 100 FEET ALONG THE SEWER, 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING ALL WATER TIGHT COMPONENTS, PRIOR TO THE ABSORPTION AREA, TO PREVENT INFILTRATION. 5. TOPSOIL COVER MAY BE VARIED (WITH 1 FOOT MINIMUM) TO ALLOW LANDSCAPING, 6. INSTALL RISERS AS NECESSARY TO BRING ALL ACCESS POINTS TO WITHIN ONE—HALF FOOT OF FINAL GRADE. 7. LOCATIONS OF ALL COMPONENTS MAY BE VARIED AS NECESSARY AS LONG AS ALL MINIMUM DISTANCES AND SLOPES MEET THOSE REQUIRED. 8. PROVIDE POSITIVE DRAINAGE OF SURFACE WATER AWAY FROM ABSORPTION FIELD AREA USING DRAINAGE SWALES AS NECESSARY. 9. SOILS AND PERCOLATION INFORMATION FROM INFORMATION PROVIDED BY H,P GEOTECH, INC., JOB NO. 100 550. 10. THIS DRAWING DOES NOT CONSTITUTE AN ISDS PERMIT. PERMIT MUST BE OBTAINED FROM APPROPRIATE CITY OR COUNTY OFFICIALS. ENGINEER MUST OBSERVE CONSTRUCTED SYSTEM BEFORE BACKFILL AND PROVIDE REPORT TO COUNTY, 11. THIS SYSTEM IS SIZED FOR TYPICAL DOMESTIC WASTES ONLY. BACKWASH OR FLUSHING FLOWS FOR REVERSE OSMOSIS UNITS OR WATER SOFTENERS OR FILTERS SHOULD NOT BE INTRODUCED INTO THIS SYSTEM. 12. SITE PLAN INFORMATION FROM JEFF TUTTLE, SEPTEMBER, 2002, 13. INSTALL BLUEBOARD INSULATION OVER SEWER PIPE WHEREVER DEPTH IS LESS THAN 5.0 FEET. 14. THE ENGINEER SHALL BE CONTACTED FOR SITE INSPECTION PRIOR TO BACKFILLING OF SYSTEM COMPONENTS. 15. DESIGN OF ABSORPTION BED BASED ON SOIL PROFILE INDICATING 1' OF TOPSOIL OVERLYING SILTY CLAY WITH SHALE FRAGMENTS TO A PROFILE DEPTH OF 14 FEET (EXISTING FIELD). GENERAL ABSORPTION BED NOTES 1. ABSORPTION LATERALS SHALL NOT EXCEED 100 FEET IN LENGTH. 2. THE BOTTOM OF THE ABSORPTION BED SHALL BE LEVEL. 3. DRAINAGE DITCHES ARE TO BE PROVIDED ABOVE AND AROUND BED, AS NECESSARY, TO PREVENT SURFACE RUNOFF FROM ENTERING ABSORPTION AREA. 4, BED LATERALS SHALL FOLLOW CONTOURS. 5. INSTALL INFILTRATOR IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. 6, BED BOTTOM AND SIDEWALLS MUST BE RAKED TO REMOVE SOIL SMEARS INCURRED DURING EXCAVATION. 7, NO EXCAVATION OF ABSORPTION FIELD IS TO BE DONE DURING WET WEATHER AND USE OF RUBBER TIRE VEHICLES OVER ABSORPTION AREA IS PROHIBITED. RECORD DRAWING DECEMBER 1 b, 2004 0 s Z �3 _ 0 in Z N �o J z as 89 2QdQ�� Z WVcqON, 0)o O Z W m co O SO \ Z (/'� OZ Z W 0 Wz W Nwq Z 0 0) 10,0 VO � = Of z �Cl) I W Co F- 5 r Z © J Q w O Y J z 0 s Z �3 _ 0 Z N �o J w as 89 2QdQ�� Z WVcqON, 0)o W�] O Z W m co O SO \ Z (/'� OZ Z W 0 Wz Q Nwq Z 0 0) 10,0 VO � = rNotL�L z �Cl) I a� Co Dt= 5 r Z © J Q w w Y J 0 0 s Z �3 _ 0 Z N �o 00 w as 89 2QdQ�� Z WVcqON, 0)o W�] O Z W ,ztk co O SO W Z (/'� OZ Z W 0 Wz Q Nwq Z 0 0) 10,0 VO M = rNotL�L PROJECT NO. SHEET1 W M J 0)o Cl)_- m0 ZW (C o� W w �[ Ir vo Q Wz Q w VO z U) = W J �Cl) a a� Co 5 r Z a J PROJECT NO. SHEET1 12" MIN, COVER 48" MAX. COVER / X\X\�//\�//\�/\//\//\//\//\/%//\//\//\//\//\//\\\///\�\� BED BOTTOM LEVEL AND ROUGHENED NATURAL GROUND B E D CROSS SECTION TYP . INFILTRATOR UNIT (TYP.) N.T.S. GRAPHIC SCALE 30 0 15 30 60 ( IN FEET ) 1 inch = 30 ft. REMOVABLE CAP 120 4" 0__\- CUT HOLE IN TOP OF SOLID PIPE INFILTRATOR UNIT FOR INSTALLATION OF INSPECTION SIDES / WELL PIPE ROyGHENEb �z OUP O 12° ell 0 O 36" INSPECTION WELL DETAIL. N.T.S. FINISH GRADE 4" COUPLIN 4" SEWER PVC CAP --\ RISER 45' SWEEP BEND 4" x 4" x 40'----/ PVC WYE Z LEAN OUT ASSEMBLY SEWER CLEAN OUT DETAIL, N. T. S. BED PLAN VIEW N.T.S. DISTRIBUTION LATERAL (BOTH ENDS) WELL ( TYP. )~ .. �x N O \ N � ~ O O Y W Lu M Ck' 3 IT �` k w J .. N { .b w Q C) = OOO_ ZW m0 � Q® W o0 R CW W 5 Q W •� YP .I. (n cc UO �z co Q J 00 'S J � T 0 � F Z 0 w U) �a y L W ansa { O Un O= W O 0 S r-) Su' Q f : a Y N . . ..... 4.0y 'asI p7 k. o_ � k , OK U VICINITY MAP SCALE: 1"=2000' GENERAL NOTES 1. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE PITKIN COUNTY REGULATIONS OF INDIVIDUAL SEWAGE DISPOSAL SYSTEMS, EVEN THOUGH ALL SUCH REQUIREMENTS ARE NOT SPECIFICALLY NOTED ON THE DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SUCH SPECIFIC DETAILS AS ARE REFERRED TO IN THE ABOVE MENTIONED REGULATIONS. 2. FLOW FOR BED: 6 HORSE STALLS * 50 GALLONS/HORSE/DAY PLUS SINK/SHOWER/TOILET/WASHER @ 63.4 GPD FOR ONE PERSON IS 363.4 GPD = AVERAGE DAILY FLOW. DESIGN = 1.75* AVERAGE = 636 GPD (Q) SEPTIC TANK: MINIMUM TOTAL TANK SIZE: 636 GPD * 1 DAY/24 HRS * 30 HRS = 795 GPD INSTALL ONE 1000—GALLON SEPTIC TANK WITH BAFFLE AND INSTALL AN EFFLUENT FILTER IN THE SEPTIC TANK OUTLET, STANDARD ABSORPTION AREA: A = Q Ft— Q=MAXIMUM FLOW 5 t=PERCOLATION RATE = 34 min./in. = 636 J34 = 742 SF USE OF STANDARD INFILTRATOR UNITS IN BED CONFIGURATION: 30% REDUCTION— (742 S.F.*0.70) @ 15.5 S.F./UNIT, 34 UNITS ARE REQUIRED. INSTALL 36 UNITS IN A 6x6 BED CONFIGURATION. 3. CLEAN OUTS ARE REQUIRED AT ALL BENDS AND AT LEAST EVERY 100 FEET ALONG THE SEWER. 4, THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING ALL WATER TIGHT COMPONENTS, PRIOR TO THE ABSORPTION AREA, TO PREVENT INFILTRATION. 5. TOPSOIL COVER MAY BE VARIED (WITH 1 FOOT MINIMUM) TO ALLOW LANDSCAPING. 6. INSTALL RISERS AS NECESSARY TO BRING ALL ACCESS POINTS TO WITHIN ONE—HALF FOOT OF FINAL GRADE 7. LOCATIONS OF ALL COMPONENTS MAY BE VARIED AS NECESSARY AS LONG AS ALL MINIMUM DISTANCES AND SLOPES MEET THOSE REQUIRED. 8. PROVIDE POSITIVE DRAINAGE OF SURFACE WATER AWAY FROM ABSORPTION FIELD AREA USING DRAINAGE SWALES AS NECESSARY. 9. SOILS AND PERCOLATION INFORMATION FROM INFORMATION PROVIDED BY H.P GEOTECH, INC., JOB NO. 100 550, 10. THIS DRAWING DOES NOT CONSTITUTE ANISDS PERMIT. PERMIT MUST BE OBTAINED FROM APPROPRIATE CITY OR COUNTY OFFICIALS. ENGINEER MUST OBSERVE CONSTRUCTED SYSTEM BEFORE BACKFILL AND PROVIDE REPORT TO COUNTY. 11, THIS SYSTEM IS SIZED FOR TYPICAL DOMESTIC WASTES ONLY, BACKWASH OR FLUSHING FLOWS FOR REVERSE OSMOSIS UNITS OR WATER SOFTENERS OR FILTERS SHOULD NOT BE INTRODUCED INTO THIS SYSTEM. 12. SITE PLAN INFORMATION FROM JEFF TUTTLE, SEPTEMBER, 2002. 13. INSTALL BLUEBOARD INSULATION OVER SEWER PIPE WHEREVER DEPTH IS LESS THAN 5.0 FEET. 14, THE ENGINEER SHALL BE CONTACTED FOR SITE INSPECTION PRIOR TO BACKFILLING OF SYSTEM COMPONENTS. 15. DESIGN OF ABSORPTION BED BASED ON SOIL PROFILE INDICATING 1' OF TOPSOIL OVERLYING SILTY CLAY WITH SHALE FRAGMENTS TO A PROFILE DEPTH OF 14 FEET (EXISTING FIELD). GENERAL ABSORPTION BED NOTES 1, ABSORPTION LATERALS SHALL NOT EXCEED 100 FEET IN LENGTH, 2. THE BOTTOM OF THE ABSORPTION BED SHALL BE LEVEL. 3. DRAINAGE DITCHES ARE TO BE PROVIDED ABOVE AND AROUND BED, AS NECESSARY, TO PREVENT SURFACE RUNOFF FROM ENTERING ABSORPTION AREA, 4, BED LATERALS SHALL FOLLOW CONTOURS, 5, INSTALL INFILTRATOR IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. 6. BED BOTTOM AND SIDEWALLS MUST BE RAKED TO REMOVE SOIL SMEARS INCURRED DURING EXCAVATION. 7. NO EXCAVATION OF ABSORPTION FIELD IS TO BE DONE DURING WET WEATHER AND USE OF RUBBER TIRE VEHICLES OVER ABSORPTION AREA IS PROHIBITED. RECEIVED, JUN 2003 p6TKIN COUNTY ENV IRCNNNT'aL HEALTH 'S z Cl N O \ N � ~ O O Y W Lu M Ck' i- Q w J o o w Q C) = OOO_ ZW m0 � Q® W o0 0 CW W a[fr OO Q W W Q (n V) cc UO �z co Q J 00 'S J � T 0 � F Z 0 w U) — W O Un O= W O 0 S r-) Q Y N o_ z OK U Un O W Q Lam�L^^ V V) N /l� L, W1 O o 0 z W U U) V) LLj Ld n (i 0 w WN LL Ld O O Q It 0) C) \ \ �0 Co N O z �- 'S z Cl N O \ N � ~ O O Y W Lu w Ck' i- Q w J o Q 'j)z Q C) (O U � z V � Z w; O U w�� z w8Nsq, �Jco�8 LL w w 0- _ c�0 QZQV z OzE^ U(f) °" ao 2Z 100- PROJECT N0. z �O W Cf) CD Cl) m o Q 'j)z Q C) = OOO_ ZW m0 � Q® o0 0 CW W a[fr OO Q W W Q ou w cc UO �z co =W 00 < 0 C m � T 0 � Z 0 J PROJECT N0. � / 20 1-1Z 1 00 /CAL. SEPTIC TANK /A SE�TIC TANK ' oll If [�T��Tzl�T� ���T� GRAPHIC ^�`'��^�^� o m oo ^o ( IN FEET ) 80 VICINffY MAP SCALE: 1"=2000' GBUt& NOTES 1. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE P|TK|m COUNTY REGULATIONS OF INDIVIDUAL SEWAGE DISPOSAL SYSTEWS, EVEN THOUGH ALL SUCH REQUIREMENTS ARE NOT SPECIFICALLY NOTED ON THE DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SUCH SPECIFIC DETAILS AS ARE REFERRED TO IN THE ABOVE MENTIONED REGULATIONS. 2. FLOW FOR BED: 5 BEDROOMS * 2 PERSONS/BEDROOM ° 100 GALLONS/PERSON/DAY PLUS 1 RESIDENTIAL KITCHEN * 4.4 CPD PLUS 2.5 TOILETS * 24.8 CPD IS: 7288.40 CPD = AVERAGE DAILY FLOW. O[3|CN = 1.75* AVERAGE = 2216.2 GPD (0) OWNER WOULD LIKE SYSTEM OVERSIZED BASED ON THE SETBACK CONSTRAINTS. THER[F0RE, THE SETBACK FROM BRUSH CREEK DICTATES AND ALLOWS FOR A MAXIMUM DESIGN FLOW (0) OF 2500 CPD WHICH RESULTS IN AN AVERAGE DAILY FLOW OF 1428 GPD. THIS RESULTS IN AN ADDITIONAL CAPACITY OF 161 GPD OR APPROX|MATELY 1 A.D.U. BEDROOM. SEPTIC TANK: MINIMUM TOTAL TANK SIZE: 2500 CPD * 1 DAY/24 HR3 * JO HRS ~ 3125 GPD EXISTING 3YTEM CONTAINS 2-1500 GALLON SEPTIC TANKS IN SERIES. THEREFORE. INSTALL 1-2000 GALLON TANK WITHOUT BAFFLE IN FRONT OF THE EXISTING TANKS, STANDARD ABSORPTION AREA: A = O j�' O=MAX|MUM FLOW ---5-- t=p[RcnL,.T|ON Rx7F ~ Jn m'r./in. ~ 2500 = 2739 3F USE OF STANDARD INFILTRATOR UNITS IN BED CONFIGURATION: 30% REDUCTION– (2739 S.F.*0.70) @ 15.5 S.F./UNIT, 124 UNITS REQUIRED. 90 UNITS IN EXISTING BED. RECOMMEND INSTALLATION OF 2 ADD'T ROWS OF UNITS FOR A TOTAL OF 120 UNITS. 3. CLEAN OUTS ARE REQUIRED AT ALL BENDS AND AT LEAST EVERY 180 FEET ALONG THE HOUSE SEWER. 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING ALL WATER TIGHT COMPONENT3, PRIOR TO THE ABSORPTION AREA, TO PREVENT INFILTRATION. 5. TOPSOIL COYER WAY BE VARIED (WITH 1 FOOT MINIMUM) TO ALLOW LANDSCAPING. 5. INSTALL RISERS AS NECESSARY TO BRING ALL ACCESS POINTS TO WITHIN ONE–HALF FOOT OF FINAL GRADE. 7. LOCATIONS OF ALL COMPONENTS MAY BE VARIED AS NECESSARY AS LONG JI AS ALL MINIMUM DISTANCES AND SLOPES MEET THOSE REQUIRED. GAS GAS 8. PROVIDE POSITIVE DRAINAGE OF SURFACE WATER AWAY FROM ABSORPTION FIELD AREA USING DRAINAGE 3WALES AS NECES3ARY, 0. SOILS AND PERCOLATION INFORMATION FROM INFORMATION PROVIDED BY H.p GE0TECH. INC., JOB NO. 100 550, JULY 31.2000. 10. THIS DRAWING DOES NOT CONSTITUTE AN |SDS PERMIT. PERMIT MUST BE OBTAINED FROM APPROPRIATE CITY OR COUNTY OFFICIALS. ENGINEER MUST OBSERVE CONSTRUCTED SYSTEM BEFORE BACKFILL 01 AND PROVIDE REPORT TO COUNTY. 11. THIS SYSTEM IS SIZED FOR TYPICAL DOMESTIC WASTES ONLY. BACKWASH OR FLUSHING FLOWS FOR REVERSE OSMOSIS UNITS OR WATER SOFTENERS OR FILTERS SHOULD NOT BE INTRODUCED INTO THIS SYSTEM. 12. SITE PLAN INFORMATION FROM WEDUW & ASSOC. JULY 2000. 13. INSTALL 8LUEBOARD INSULATION OVER SEWER PIPE WHEREVER DEPTH IS LESS THAN 5.0 FEET. 14. THE ENGINEER SHALL BE CONTACTED FOR SITE INSPECTION PRIOR TO BACKFILLING OF SYSTEM COMPONENTS. 15. DESIGN OF ABSORPTION BED BASED ON SOIL PROFILE INDICATING 1' OF TOPSOIL OVERLYING SILTY CLAY WITH SHALE FRAGMENTS TO A PROFILE DEPTH OF 14 FEET. GENERAL ABSORPTION BED NOTES 1. ABSORPTION LATERALS SHALL NOT EXCEED 100 FEET IN LENGTH. 2. THE BOTTOM OF THE ABSORPTION BED SHALL BE LEVEL. APPROX. WELL C 7620 3. DRAINAGE DITCHES ARE TO BE PROVIDED ABOVE AND AROUND 8[D, AS LOCATION NECESSARY, TO PREVENT SURFACE RUNOFF FROM ENTERING ABSORPTION AREA. 4. BED LATERALS SHALL FOLLOW CONTOURS. 5. INSTALL INFILTRATOR IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. O. BED BOTTOM AND S|DEWALL3 MUST BE RAKED TO REMOVE SOIL SMEARS INCURRED DURING EXCAVATION. if 7. NO EXCAVATION OF ABSORPTION FIELD IS TO BE DONE DURING WET WEATHER AND USE OF RUBBER TIRE VEHICLES OVER ABSORPTION AREA IS PROHIBITED PROJECT NO. i SHEET 1 z w U5 C0 rn of 0 Co cf) L3 Ld PROJECT NO. i SHEET 1 z w U5 C0 rn of 0 cf) L3 PROJECT NO. i SHEET 1