HomeMy WebLinkAboutpitkin.eh.264333301005 (2004)Permit # 04086
Pitkin ^ounty Environmental Health Department,
Perm or an Individual Sewage Disposal Sy m
0405 Castle Creek Road, Suite 10, Aspen, Colorado 8ib11
Phone 970-920-5070 / FAX 970-920-5077
Parcel ID # 2643-333-01-005
Type of permit New( ) Repair( ) Addition/Remodel to House( x ) addition plus poolhouse
Name of Owner Nikos Hecht
Street Address 600 Owl Creek Road
Property legal description Lot 5, Owl Creek Ranch
Size of lot 60.78 acres Total square footage of the house Over 6000 sq ft
Water source Owl Creek wells
# of bedrooms in house 7
Caretaker unit
# of bedrooms in caretaker unit
# of offices, lofts & similar sized rooms in house
Total square footage of the caretaker unit
# of offices, lofts & similar sized rooms in caretaker unit
Designed for what # rooms (list) Adding one bedroom to 6 bedroom house + pool house for use by 10 people/ day
Y
OL 6e
Permit information
kD
Designed by Schmueser Gordon Meyer S2Q� ` Z 200der.
Mailing Address 118 W. 6th St., Ste 200
Perc rate 240mpi Profile hole depth 8.5 ft Depth to groundwater or bedrock
Minimum Septic tank capacity 788 gallons Minimum Absorption area
Comments
Greater than 8.5 ft
1670sq.ft/ eff. Area 1719
Septic permit approved per compliance with the engineer design and specifications dated September 24, 2004.
Any changes must be approved by this department and the design engineerrg for to them being made.
Minimum horizontal distances between components of the system and physical features shall conform to the Pitkin
County ISDS regulations.
This design is for an ETA bed design. Sizing was based on 32"/year. A 1000 gallon two compartment tank should
be installed with an effluent filter on the outlet. The field will be distributed via a level manifold and the effective size
should be 1719 sq ft. There should be 2 feet for sand meeting the gradation requirements in section 6.28.680 F of
the ISDS regulations.
This department does not endorse any brand of products. This permit must be kept on-site during installation.
The engineer must do a final inspection of the installation and submit an as -built letter to this department. This
department must also be called for an inspection with a minimum of 48 hours advanced notice.
'Revegetation over the area of the field is very important for the functioning of the system. Pitkin County has guidelines that must be
followed to assure the plants that are introduced are appropriate for the conditions of the area. The use of native plants is strongly
encouraged.
Permit approved by: l�C cLoc �c Date:
Plans and specifications of the proposed individual sewage disposal system have been reviewed and are considered
satisfactory. Permission is hereby granted to the owner or the agent to perform the work indicated in accordance with the Pitkin
County ISDS Regulation in effect at the time of issue. This permit becomes invalid 6 months from the date that the permit was
issued unless system construction has commenced or an extension has been approved in writing by the Department.
As -built drawings must be included with this permit before the final approval will be issued.
Installer: 4 t
Final approval: �c c Date: d�
PITKIN COUNTY ENVIRONMENTAL HEALTH DEPARTMENT
APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM
0405 Castle Creek Road, Suite 10, Aspen Colorado 81611
Phone (970) 920-5070 Fax (970) 920-5077
Name of OWNER /V ►R -t2> l7f-(;H /
Owner's Mailing Address �i��Q rA21- (2e,L4 �*
Busi
Home Phone: E-mail Address:
Primary C ntact Person (all communication regarding this permit will go through this person)
Name -
Company
Contact Mailing AddressJ�Z�X-
City, State, Zi Z Business Phone : 1j qm 1,5
Cell Phone : ,? 6 -ax: �-.� E-mail Address: v N
Parcel W # (available from assessor's office r
at 920-5160 or at www.pitkinassessor.org ) z -�- -AL - 3 3 - 0 L--0 -!�2 �2
Street address of property OWI- 11
Legal Description: Lot 16- ,Block Filing Subdivision
Size of lot: � acres. Type of proposed structure: �� cc � N( I L.1 M
Total square feet of house # of bedrooms (potential) in house
Caretaker Unit: Attached ( ) Detached ( )
Total areas . ft. of caretaker unit # of bedrooms(potential) in caretaker unit
Permit is for: New Home ( } Repair due to failure ( ) Remodel/Addition (X)"
) Emergency use ( )
Water: Private well ( ) Spring ( ) Stream ( ) Community/Public Water System( )
If community system: Name of system
The fee for a ISDS application is $600 for a permit that takes 6 hours or less for the department to approve. If approval takes
longer than 6 hours, a rate of $100 per hour will be charged. The maximum fee is $1000. The basic fee of $600 is due at the
time of application. The remainder, if any, will be due in two stages: first, at the time of issuance of the ISDS permit; second,
before final approval of the ISDS permit.
Application for an individual sewage disposal system is hereby submitted. I hereby certify that the above information is true and
accurate and that I have provided true and accurate information on locations of all existing and proposed wells, contour
intervals, buildings, property lines, ditches, slopes, waterlines, springs, suction or irrigation lines, drinking water cisterns, drain
tiles, irrigation ditches, lakes, water courses, streams, floodplains, dry gulches, and existing septic systems. I hereby certify
that any such features not shown on attached site map are not present. Issuance of the permit does not imply the approval of
any other permit required for construction pursuant to Pitkin County codes. No construction may be undertaken until all
approvals and permits have been obtained.
The Pitkin County Environmental Health DepartmentjIttkin Cou n employees of these agencies will be held harmless
should the individual sewage disposal system fail malfunct' T permit to con uct is issued on information submitted by
the applicant or his/her representatives. Th � er assum f� sponsibility in ase of failure of the system.
Date
Signature of applicant
Received by
G:lisdMisds appliclisdsapp Rev0501
Receipt #
-J,-CI LL09-0213(OL13) 4jieaH -AI-13 00 u1-,i4Td d00:E0 i3O fro 100
Pitkin County Environmental Health Department
Contact Log Sheet
t►CWL�i•�_
Parcel ID#: Address:
Person Spoken To Comments Action to be Taken
Few 01 M
I� ..,.,�:.�..:....
r 1
0"F
.�M
®AIOM1. M MIN.511 EM
P. 1
COMOICATION RESULT REPORT ( NOV-29-20 9:36AM ) * * *
FAX HEADER: ENVIRO HEALTH NAT RESOURCE
TRANSMITTED/STORED : NOV.29.2006 9:34AM
FILE MODE OPTION ADDRESS RESULT PAGE
-- -- - --- --- ---- ---- -----------
815 MEMORY TX SGM OK 2/2
9203038 OK 2/2
----------------------------------------------------------------------------------------------------
REASON FORERROR
E- 1) H AN (3 U P OR LINE FAIL E-2) BUSY
E-3) NO ANSWER E-4) NO FACSIMILE CONNECTION
PITKIN COUNTY ENVIRONMENTAL HEALTH & NATURAL RESOURCES
DATE: 11/29/2006
Send to: Kevin Bourke From: Alicia Gomez
Fax Number: 920-3038 Phone Number: 920-5057
CC: SGM Number of Pages, Including Cover: 2
CC Fax Number:
O URGENT b REPLY ASAP o PLEASE COMMENT n PLEASE REVIEW Ml FOR YOUR
TNFORMATION
COMMENTS:
Septic Permit #04086 for parcel 2643-333-01-005, owner Hecht,
has been finalized_ Please feel free to call 920-5070 if you have
any questions.
fax Cover
Pitkin County Environmental Health and Natural Resources
0405 Castle Creek Road Suite #10, Aspen, CO 81611
Phone (970) 920-5070 1 Fax (970) 920.5077
Web site www_aspenpitkin.com/ehnr
1 j
IcaMU FyRNIN EpS I GO.RDON i EYORS MEYER GLEN WOOD SPRINGS ASPEN
-t-+"� 1 1 8 W. 6TH SUITE 200 P.O. BOX 21 55
f�� S+URN
GLENACM SPRINGS, CO 81601 ASPEN, CO 81612
I
970-945-1004 970-925-6727
--- Fx: 970.945.5948 FX! 970-925-41 57
I � I
Carla Block-
-- --T- --- Pitkin County Env iromnental Health
0405 Castle Creek Road
Suite 10
- - Aspen CO 81611
-_ - RE: Hecht Residence ISDS-OAN-1 Creek Ranch
Dear Carla:
I The purpose of this letter is to provide documentation that the ISDS was installed per the permit
and Plans prepared by SGM dated September 24. 2004. I obsen-ed the s} stern prior to backfill.
Attached is a record drawing prepared by the contractor.
Sincerer .
SCHMUESER GORDON MEYER, INC.
J
Dan Coklev. P.E.
I:\2004\2004-301\Corresp\11-16-06 ISDS ltr.doc
r- .e.
143V"
0
�3
t
st
`TRT_ v,'.! 91C N �
A*"k
ts�
-
Mr • �.. t 1
a-
1. -
• rY
En
L�
Fift' NOY
NO SEPTIC PERMIT REQUIRED FORM
Date: (2a�u&
Owner's Name: �R
Project Name:
Address of Property'n
Building Permit number:
Parcel ID-#- %o � -,3 -;3 01—��
Scope of Project:
Rntumenw fleall
Remodel does not increase the bedroom/potential bedroom count
Existing septic system is sized for this project
New buildings do not need a septic system (i.e. garage, shed, barn, etc.)
Project is not located -in the area of the existing septic system
No septic permit is required for this project. No further review is required by
Environmental Health.
FOOD SERVI-CE FACILITY
This facility contains a retail food establishment. Environmental Health has
reviewed and approved the plans.
V-
t
PitkinEnvironmental Health
NO SEPTIC PERMIT REQUIRED FORM
Date:I! a I � �p
0
Owner's Name:
Project Name:
Address of Property: (p 00 owl cARR_.K- KGF _
Building Permit number:
Parcel ID #
I ► A P i
Scope of Project:
Remodel does not increase the bedroom/potential bedroom count
t
Existing septic system is sized for this project �qu 412-1 � 4,,t-&
New buildings do not need a septic system (i.e. garage, shed, barn, etc.)
Project is not located in the area of the existing septic systPm
No septic permit is required for this project. No furt
Environmental Health.
FOOD SERVICE FACILITY
This facility contains a retail food establishment. Env
reviewed and approved the plans.
0405 Castle Creek Road, Suite 10 Aspen, Colorado 81611
(970) 920-5070 fax 920-5077 www.pitkingov.com
HMIUESER 160Rb N I MEYE
G I', N E E R S S U R V EY O R S
I
�arla Block
?itkin County Environmental Health
)405 Castle Creek Road
Suite 10
Aspen CO 81611
Hecht Residence ISDS-Owl Creek Ranch
Carla;
11VU ED
APR 2 4 2006
PITKIN COUNTY ENVIRONMENTAL
HEALTH & NATURAL RESOURCES
The purpose of this letter is to provide documentation supporting the addition of an outdoor
structure on the above property which would contain a lavatory sink and a toilet for the use of site
- -- -- workers following the completion and certificate of occupancy for the current residence under
construction. Through the existing construction, portable sanitary facilities will continue to be
available for site workers.
-- ----" The intention of the owner is to provide a sanitary facility outside of the main residence that
would mainly serve landscape contractors, although other site laborers may use the facility. This
structure and facility would be provided in lieu of using the facilities within the main residence,
as typically occurs in a vast majority of structures throughout Pitkin County. Therefore, the
addition of this structure will not in essence increase the flow to the ISDS.
Nevertheless, the recently design and installed system was analyzed to determine what additional
capacity exists within the system. It is conservatively estimated that a weekly average of 1
worker per day will be on-site. Employees typically generate 15 gpd per 8 -hour shift. The
calculation from the approved plan determines that the necessary size is 1670 sf for a design flow
of 630 gpd. This equates to a design loading rate of 0.38 gpd/sf. The actual system constructed is
1718.75 sf, an excess area of 48.75 sf or 18.4 gpd. Therefore the system has the capacity to serve
the proposed additional use.
Sincerely,
SCMUESER
INC.
Dan Cokley, P
CC: Jodi, Galambos Architects
I:\2004\2004-301\Corresp\04-21-06 ISDS Itr.doc
GLENWOOD SPRINGS
ASPEN
CRESTED BUTTE
....1.18 W. 6TH, SUITE 200
P.O. BOx 21 55
P.O. BOX 3088
GLENWOOD SPRINGS, CO 81601
ASPEN, CO 81512
CRESTED BUTTE, CO 81 224
970-945-1004
970-925-6727
970-349-5355
FX: 970-945-5948
FX: 970-925-4157
Fx: 970-349-5358
Hecht Residence ISDS-Owl Creek Ranch
Carla;
11VU ED
APR 2 4 2006
PITKIN COUNTY ENVIRONMENTAL
HEALTH & NATURAL RESOURCES
The purpose of this letter is to provide documentation supporting the addition of an outdoor
structure on the above property which would contain a lavatory sink and a toilet for the use of site
- -- -- workers following the completion and certificate of occupancy for the current residence under
construction. Through the existing construction, portable sanitary facilities will continue to be
available for site workers.
-- ----" The intention of the owner is to provide a sanitary facility outside of the main residence that
would mainly serve landscape contractors, although other site laborers may use the facility. This
structure and facility would be provided in lieu of using the facilities within the main residence,
as typically occurs in a vast majority of structures throughout Pitkin County. Therefore, the
addition of this structure will not in essence increase the flow to the ISDS.
Nevertheless, the recently design and installed system was analyzed to determine what additional
capacity exists within the system. It is conservatively estimated that a weekly average of 1
worker per day will be on-site. Employees typically generate 15 gpd per 8 -hour shift. The
calculation from the approved plan determines that the necessary size is 1670 sf for a design flow
of 630 gpd. This equates to a design loading rate of 0.38 gpd/sf. The actual system constructed is
1718.75 sf, an excess area of 48.75 sf or 18.4 gpd. Therefore the system has the capacity to serve
the proposed additional use.
Sincerely,
SCMUESER
INC.
Dan Cokley, P
CC: Jodi, Galambos Architects
I:\2004\2004-301\Corresp\04-21-06 ISDS Itr.doc
Noe
October 28, 2005
Kevin Bourke
P.O. Box 10493
Aspen, CO 81612
Re: Parcel ID #: 2643-333-01-005
Property Address: 600 Owl Creek Road
Legal Description: Lot 5, Owl Creek Ranch
Permit #: 04086
Dear Mr. Bourke:
As per our correspondence to you on April 6, 2005, the Environmental Health & Natural
Resources Department would like to remind you that we are still unable to complete the
processing of the Individual Sewage Disposal System (ISDS) permit for the above stated
residence/property.
It is mandatory that our office receives an "As Built" letter from the engineer who
designed the system. The letter will confirm that they observed the installation of the
system as designed. Any changes to the system must be noted in the letter or by a new
set of plans. Specifically, we need the "As Built" to also address sand specs. The
attached drawing should also show the location of the new pond. The Building
Department will not issue a Certificate of Occupancy for this property until they are
notified that the ISDS permit process is complete.
This office must receive the "As Built" letter from the engineer no later than November
17, 2005.
Please contact me with any questions. Thank you, in advance, for your help and
cooperation in this matter.
Sincerely,
Alicia Gomez.
Administrative Assistant
Environmental Health & Natural Resources
cc: Schmueser Gordon Meyer, Engineer
Nikos Hecht, Owner
phone 970-920-5438
fax 970-920-5077
0405 Castle Creek Rd, Aspen CO 81611
e-mail carlab@ci.aspen.co.us
To: Kevin Burke From: Carla Block
Fax: 920-3038 Pages: 2
Phone: Date: 10/21/04
Re: septic permit CC: Dan Cokely
❑ Urgent 0 For Review ❑ Please Comment ❑ Please Reply ❑ Please Recycle
am a little unclear about some of the components in this design. The general notes call for gravel and
perf pipe, but the drawing indicates gravelless chamber units. Dan, could you clarify this for me and the
installer?
Also, it is my understanding from several engineers that pressure distribution to any type of sand filter
system is appropriate for more consistent settling over time. A pump is not specified in this case. Just
wondering if that was considered or if there is a reason you have decided not to go with a pressure
distribution system?
A gradation report for the sand must be submitted to this department. For an ETA bed the gradation
requirements must be 100% passing sieve size 4, 50-55% passing sieve size 40, and less than 15%
passing sieve size 200.
If you have any questions regarding this permit, please give me a call.
Thank you,
Carla
Pitkin
Environmental Health
NO SEPTIC PERMIT REQUIRED FORM
Date: -- t�
Owner's Name:
Project Name:
Address of Property: 0 Caw 1
Building Permit number:
Parcel ID #
Scope of Project:
Remodel does not increase the bedroom/potential bedroom count
Existing septic system is sized for this project 1 2-�
New buildings do not need a septic system (i.e. garage, shed, barn, etc.)
Project is not located in the area of the existing septic system
No septic permit is required for this project. No furth
Environmental Health.
FOOD SERVICE FACILITY
This facility contains a retail food establishment. Envir
reviewed and approved the plans.
0405 Castle Creek Road, Suite 10 Aspen, Colorado 81611
(970) 920-5070 fax 920-5077 www.pitkingov.com
f 1 '
SOH �ERI VOkDO� I MEYEk GL.ENWOOD SPRINGS ASPEN CRESTED BUTTE
.1.1.8 W;. 6TH,. SUITE 200 P.O. BOX 21 55 P.O. BOX 3088
E N G 1 N E IR S :1 S I1 R V E Y O; R S GLENWOOD SPRINGS, CO 81601 ASPEN, CO 8161 2 CRESTED BUTTE, CO 81 224
-------- ------ -- ---=--{-. > ,-:,- 970-945-1004 970-925-6727 970-349-5355
FX: 970-945-5948 FX: 970-925-4157 Fx: 970-349-5358
!
i I '
Carla Block
- RECEIVED
Pitkin County Environmental Health
__ ._.___ f........}-.... 10405 CAstle'Creek Road
..... ,suite 10 APR 2 4 2006
AAspen CO 81611
_ .._....- �.._ _ _ ._. PITKIN COUNTY ENVIRONMENTAL
{ RE Hecht Residence ISDS-Owl Creek Ranch HEALTH & NATURAL RESOURCES
..._...
. __. ..
Dear Carla;
The:puxpose of this letter is to provide documentation supporting the addition of an outdoor
;structure on,the above property which would contain a lavatory sink and a toilet for the use of site
workers following the completion and certificate of occupancy for the current residence under
-- -. - construction. Through the existing construction, portable sanitary facilities will continue to be
available for site workers.
The intention of the owner is to provide a sanitary facility outside of the main residence that
would mainly serve landscape contractors, although other site laborers may use the facility. This
structure and facility would be provided in lieu of using the facilities within the main residence,
as typically occurs in a vast majority of structures throughout Pitkin County. Therefore, the
addition of this structure will not in essence increase the flow to the ISDS.
Nevertheless, the recently design and installed system was analyzed to determine what additional
capacity exists within the system. It is conservatively estimated that a weekly average of 1
worker per day will be on-site. Employees typically generate 15 gpd per 8 -hour shift. The
calculation from the approved plan determines that the necessary size is 1670 sf for a design flow
of 630 gpd. This equates to a design loading rate of 0.38 gpd/sf. The actual system constructed is
1718.75 sf, an excess area of 48.75 sf or 18.4 gpd. Therefore the system has the capacity to serve
the proposed additional use.
Sincerely,
SCMUESER GORAMISMWEP, INC.
qJt, loco
Dan Cokley, PE
CC: Jodi, Galambos Architects
I:\2004\2004-301\Corresp\04-21-06 ISDS ltr.doc
,rte +.rirr
10/07/2004 09:48 FAX 970 945 5948 SCHMUESER GORDON MEYER IM 002/005
OCT -06-2004 11:25 P—p GEOTECH P.02i05
f lepworrh-T'awlak cleotcclNnical, 1ric,
5020 County Road 154
Cilcnwncul Srringx, ColoraJo 81601
G99bedh Yhopc: 970-945-7988
HEPWORTH-PAWLAK GEOTECHNICAL Fax: 970-945-8454
email: ltpg&a4hpLeocech.c,m
September 30, 2004 z � ` `
Nikos Hecht OCT 0 7 2004
600 Owl Creek Road
Aspen, Colorado 81611 PITKIN uUuri P,,'
ENVIRONMENTAL. HEALTH Job No. 104 311
Subject: Percolation Testing, Proposed Addition to Septic Disposal System for
Bedroom and Pool House Additions, Lot 5, Owl Creep Ranch, 600 Owl
Creek Road, Pitkin County, Colorado,
Dear Mr. Hecht:
As requested by Jodie Fielding with Galambus Architects, Hepworth - Pawlak
Geotechnical, Inc. performed percolation testing at the subject site. The testing was
done in accordance with our agreement for professional services to you, dated
September 7, 2004. We previously conducted a subsoil study for the proposed pool and
pc?ol house and presented our futdings in a report dated May 28, 2004, Job No. 104
311.
One profile pit and three percolation holes were excavated on September 29, 2004 in
the area designated by Jodie Fielding at the locations shown on Figure 1. The test holes
(nominal 12 inch diameter by 12 inch deep) were hand dug in the bottom of shallow
backhoe pits and were soaked with water one day prior to testing. The subsoils exposed
in the Profile Pit consisted of about I foot of topsoil overlying stiff, sandy silty clay
with shale fragments to the bottom pit depth of 81A feet. No free water was observed in
the pit and the soils were slightly moist to moist.
Percolation testing was conducted on September 30, 2004, by a representative of
Hepworth - Pawlak Geotechnical, Inc. The percolation test results are summarized on
Table 1. The percolation test results indicated an infiltration rate of 60 minutes per inch
for tests P-1 and P-3- Test P-2 did not have an infiltration rate. Based on the
subsurface conditions encountered and the percolation test results, we recommend the
sel)tic disposal system be designed by a professional civil engineer.
Parker 303.841-7119 a Colorado Springs 719.633.5562 0 Silverthc nic 970-458-1989
.r■■111r
10/07/2004 09:49 FAX 970 945 5948 SCHMUESER GORDON MEYER/0003/005
OCT -06-2004 11:26 H—P GEOTECH P.03i05
Nikos Hecht
September 30, 2004
Page 2
If you have any questions or need further assistance, please call our office.
Sincerely,
HEPWORTH - PAWLAK OTE C.
•.N A0.4
Jordy Z. Adarnson, Jr., P. ° 9707 p`
Rev. by: DEH ''�,,����,,•�''��
ONp1,
JZ.A/dib
attachments Figure 1 - Location of Percolation Test Holes
Table 1 - Percolation Test Results
cc: GaWnbos Architects - Attn: Jodie Fielding
Scbmueser Gordon Meyer - Attn: Dan Cokley
lob -No. 104 311
400srmmailr
10/07/2004 09:49 FAX 970 945 5948 SCHMUESER GORDON MEYER
OCT -06-2004 11 26 H -P GEOTECH
APPROXIMATE SCALE
1" = 40'
M
0004/005
P. 04/05
60
55
/
O
50
/
EXISTING
CLEANOUT
/
P 3
/
e
�
PROFILE
PIT ■ P 1
55
/ /
Q P 2
i
/ O
/EXISTING
/
/
/
CLEANOUT
/
50
/
EXISTING
/
SEPTIC FIELD
45
104 311 HEPWORTH—PAWLAK LOCATION OF PERCOLATION TEST HOLES Figure 1
GEOTECHNICAL, INC,
10/07/2004 09:49 FAX 970 945 5948 SCHMUESER GORDON MEYER U005/005
-OCT-06-2004 11:26 N—P GEOTECH P.05i05
HEPWORTH-PAWLAK GEOTECHNICAL, INC.
TABLE 1
PERCOLATION TEST RESULTS
JOB NO. 104 311
HOLE NO.
HOLE --VCENr.TH
Y
ER
WATER
I DROP IN
AVERAGE
DEPTH
I INTERVALF
DEPT H AT
DEPTH AT
f WATER
PERCOLATIOr
(INCHES)
(MIN)
START OF
END OF
LEVEL
RATE
INTERVAL
INTERVAL
(INCHES)
(MINJINCH)
P-1
i 40
(INCHES)
(INCHES)
6%
'/2
15
7
I 6'/2
61/4
6
61/,
6
514
5'/2
......... .
P-2
! 43
i 8
7•/.
15
/a
7%
1
73/6
0
1A
........7%
71/2
--'
0 '
7'/1
7%
0
7'/,
43/.
_0 ...__�
2'/. i
15
7'/2
7
�'d not per c
P-3 I
4S
- _ 41/2
4%
... _
4'/.
4 I
'/a
4
3%
3%
ays
'
.__....---
1/1 <
60
Note: Percolation test holes were hand dug in the bottom of backhoe pits and soaked
on September 29, 2004. Percolation tests were conducted on September 30,
2004. The average percolation rates were based on the last two readings of
each test.
TOTAL P.05
d w
/07/2004 09:48 FAX 970 945 5948
. OCT -06-2004 1125 GEOTECH
Tn fvSWllT P%I FORIJ
SCHMUESER GORDON MEYER
Post -it' Fax Note
To
Co./Dept. uh1qRG
Phone #
Fax # % • .�
7671 1 Date
From
9001/005
OCT 0 7 2004
PITKiN COUNTY
ENVIRONMENTAL HEALTH
OAT= /D ,o -/— PROJECT NO.: 3/1
3/1
rROiU:
Nurnbar of Pages:
(including this page)
Mi=SSAGE:
The original of this transmittal will be sent by:
r/ Ordinary Mail 'fa
Fax Only 1-0
Overnight Iar
Other `2
The inforn ation contained in this facsimile message is confidantial and intended for the scia use of the
individt.fai named above. 11 you are not the intended recipient, received this communicatir')rt in rror, or if
problems occur with transmission, plaase notify us at 970-945-7988.
Sent 3y: �� 1�
/ z
33'$ 54'-8' 34'-4• I/'4
501-Z
I 1 I i 23'-8' 26'$
PROPOSED PLAN GENERAL NOTES: ; e REFER TO A25'� RQFER TO A2.4
--- ---__.�__�__------'--' ---------------------------------------f'---
w i
! 1. ALL DIMENSIONS ARE TO OUTS/Df FACE OF STUD AT ! ' ___48----�—
I I EXTERIOR WALLS OR FACE OF STUD , INTERIOR WALLS I
I
OR TO CENTERLINE OF POSTS. UN.O. !
2 GRID LINES ARE TO OUTS/DE FACE OF STUD AT EXTERIOR-
WALLS,CENTERUNE OF POSTS CENTERLINE OF DEMISING
WALLS OR EXTERIOR FACE 01` CONCRETE FOUNDATION UDN.
• I 3. NEW EXTER/OR WALLS SHALL BE 2x6 AND 2x4 STUD FRAM/NG j
AT Y-4.OL.W/ 3/4 AIR SPACE BETWEEN
ST S7 TO _ _ _ _ _ _ _ _ _ _ _
MATCH EX/STING CONSTRUCT/ON I I, ' ;
!��•/� ! ! 4. NEW INTERIOR WALLS SHALL BE 2x6 W000 FRAMING AT i i i' i' 03
r-4'OGIUANJ 2x4 WOOD FR TO BE - - - - - - - -
OW
U
z
OVERALL ENTRY LEVEL FLOOR PLAN
NORTH
G A L A M B O S
ARCHITECTS INC.
300 D AABC
ASPEN, CO 8 1 8 1 I
(9 70) 429-128 a
29-1288
W
U O
Q
WO za
U <o
WO wu
00 �z
U0-
Ld
oZ
O 0�
WQ 10
O 0
Z
NW
Ll..
2ivm ron o�rz
PPoOnq oe.(a.w
P2axr oe.oi.o4
PERMrM ,�_,p]:f
xeJo°w
PAON110E Qe.I ].04
Puwr oe.ze.w
�Joow
PKJiME 0].12.04
Pq1 Iw 07.23.04
REQUIRED TO MATCH EXISTINGCONSTRUCT/ON.
! 5. DIME
------------------'i–='
I
'ONS AT EXTERIOR DW RS ANO WINDOWS ARE TO CENTERUNf.
j SIZES ARE BASED ON CASE WINDOWS. CONTRACTOR /S RESPONSIBLE FOR j
ROUGH OPENINGSPER MANUFACTURER SPEC/F/CATIONS. WINDOW
i
7
e
!
j
i MANUFACTURER TO PRO✓lDE SHOP DRAW/NGS FOR APPROVAL PRIOR i
TO FABRICAT/ON AND INCLUDE TEMPERED GLASS WHERE REQU/RED BYCOPE.
+ -
m M
6. PROVIDE SOUND INSULATION /N WALLS, FLOORS AND CEILINGS OF ALL
ROOMS•ALSO SURROUNDING ALL MECHANICAL DUCTING.
rO
^�
i
,
BREAKFAST
ROOM MECH.
v
I ALL PI9ES TO BE WRAPPED W/R25 INSULATION.
_ _
1
--- - ------
i 7. SEE MO SERIES FOR INFORMATION ON WINDOWS AND DOORS. i
VQ
�:–DAT-UM--€LEYAFJON 1 MOUZ EQUALS EX IA'TI HOUSE TOP OF
PLYW00D !? WING ENGVE ELEVATION /0375 NJFJ
'3
-'
�, , ,
_1 ~ ~ "- -
1
, – –
-� -
9. CONTRACTOR 70 COORDINATE INTER/OR DRAW/NGS BY MICHAEL MfI S j
WITH ARCH?ECTURAL DRAWINGS16TO NEW FRAMING AND NOTIFY
�i
GARAGE
MASTER BATH
ARCHITECT OF DISCREPANCIES. 1
_
l0. CONTRACTOR TO COORDINATE FINISHES SPEC/PIED WITH INTER/OR F/N/SH! Ai
SCHEDULE PRIOR TO ORDERING AND INSTALLATION OF FINISHES. i
N
-
- -
' ! FAMILY
IR
'
.. _ _ ... AZA REfER io'A25
CLOSET
�
--------- --- --'----'-
-
-
------
i FAMILY PAIDR.
MUD
m
_
---------
m
!
ON
!
BED 08 SUNROOM OFFICE I
F
a
r
o
PANTRY
--
- !
i
M
i
i
GUEST BEDROOM
DINING
--{-r-==-==-
'PNDR.
GUEST BATH !
N
,
1 T
' - MASTER BEDROOM
,
PASSAGE j ON —T1
--
------- ---- ---
ti
– - -- I
I
BED 01 BED 02 I
GA
j _
IERY
- - --
- - - --
`
ENrRYi
`--- LIBRARY- - - -"
I
I i
-- ;-----------------
'
j
- -- - ---------------------------
-------- - - --- -- - - - -- - - - -- -
�f--DN
! ----
--'----------------------
,
I �W
----'–`------------------------'-------------------
= '
6
1rnNG
,
! i -- -
_.___–.___________________–___._–_.____.___ W
__________...____.__._________-______________-_____ -. _..________
- -
--
,
r --
I
ti!
,
,!• - - •
• 1
!
!
i
i f------- T-- ---I,
REFER TO REFER T0742.3__ -�
34'-4'
301 !7'-P
24'-F
16-10'
1 1
A42 Af 7
1
M.1
p
ASi
2
M.I
A
OVERALL ENTRY LEVEL FLOOR PLAN
NORTH
G A L A M B O S
ARCHITECTS INC.
300 D AABC
ASPEN, CO 8 1 8 1 I
(9 70) 429-128 a
29-1288
W
U O
Q
WO za
U <o
WO wu
00 �z
U0-
Ld
oZ
O 0�
WQ 10
O 0
Z
NW
Ll..
2ivm ron o�rz
PPoOnq oe.(a.w
P2axr oe.oi.o4
PERMrM ,�_,p]:f
xeJo°w
PAON110E Qe.I ].04
Puwr oe.ze.w
�Joow
PKJiME 0].12.04
Pq1 Iw 07.23.04
2Y-2 3/8
VJF.
I
;11
-5 //2 1' -5 //2 ''
VJF. VJF.
UPPER LEVEL FLOOR PLAN
CONSTRUCTION KEY:
NEW EXTERIOR WALL
TO MATCH EX/STING
CONSTRUCT/ON
NEW 2X INTER/OR WALL
EXIS77NG CONSTRUCTION
TO REMAIN
PROPOSED PLAN GENERAL NOTES:
I ALL D/MENS/ONS ARE TO OUTS/DE FACE OF STUD AT
EXTERIOR WALLS OR FACE OF STUD AT INTER/OR WALLS
OR TO CENTERLINE OF POSTS. UND.
2 GRID LINES ARE TO OUTSIDE FACE OF STUD AT EXTERIOR
WALLS 0 EXTERIOR F TO,CCONCRE7 FOUNDATION UDN.
J. NEW EXTERIOR WALLS SHALL BE 2x6 AND 2x4 STUD FRAM/NG
AT P-4'OD.W/ 3/4'AIR SPACE BETWEEN STUOS.(UDNJ TO
MATCH EXISTING CONSTRUCTION.
4. NEW INTERIOR WALLS SHALL BE 2x6 WOOD FRAM/NG AT
P-4'ODfUDNJ 2x4 WOOD FRAMING TO BE USED WHERE
REQUIRED TO MATCH EXISTING CONSTRUCTION.
S. DIMENSIONS AT EXTERIOR DOORS AND WINDOWS ARE TO CENTERLINE.
SIZES ARE BASED ON CASE WINDOWS. CONTRACTOR IS RESPONS/BLE FOR
MANUFACTURER TO PRO✓IDEFSHOPRDRAWINGSIFFORIAPPROV PRIOR
TO FABRICATION AND INCLUDE TEMPERED GLASS WHERE REQUIRED BY CODE.
6. PROVIDE SOUND INSULATION IN WALLS.FLOORS AND CEILINGS OF ALL
OIONS To BE WRAPPED W%R� INSUULLATONT/NG.
7. SEE AO SERIES FOR INFORMATION ON WINDOWS AND DOORS.
8. DATUM ELEVATION I00'- EQUALS EX /STING HOUSE TOP OF
PLYWOOD M LIVING EQUALING SITE ELEVATION /03.75 NJFJ
9. CONTRACTOR TO COORDINATE INTERIOR DRAWINGS BY MICHAEL MEINERS
W?H ARCHITECTURAL DRAWINGS PRIOR TO NEW FRAMING AND NOTIFY
ARCHITECT OF DISCREPANCIES.
l0. CONTRACTOR TO COORDINATE FINISHES SPECIFIED WITH INTER/OR FINISH
SCHEDULE PRIOR TO ORDERING AND INSTALLATION OF FINISHES
VJF.
u
I
RECREAnO1N
STORAGE 0 T-6'
004 CO ETE CARPET ------7
VENT PER MRL.
1p
CARPET
§C
j
WINE ROOM Z
om
RECREAnON
ANw,
MECH.
005
006
re
N'
m�N�
R
'
R.O.
O
TICARP
x
O
E PER /RD.
BATH B
OC
OD2
EQ. EQ.
UP
CODE APPROVED
HANDRAIL
ANGLE WALL FROM
EXISTING CORNER
DDEE
TpARRS
�toLEGRESS
I
VZI
EXISTING SITE WALL
LOCATION OFA LIGHT WELL
TO BE DETERMINED BY
CENTERLINE OF WINDOW.
/5' - 4
w
x
NORTH
3
LIGHT WELL METAL GRATE
ABOVE &AFFIF/XED LADDER
PER /RG.
LOWER LEVEL FLOOR PLAN
VERIFY WITH MECH.
G A L A M B O S
ARCHITECTS INC.
300 D AABC
ASPEN, CO B 1 61 1
(970) 429-1266
W
W
0
W
0e
J <o
WO ED c)
Q O LL' -7
C) a-
cr-� Oa
Z
�O 0�
UUO
W- Lo
Z
O oY
Z a_
W
mum ran wre
Pn1cINo 06.1aos
POTIR Oe.01.04
11u ae.m.o.�
PmNlr ae.o�.w
waow
PAO41eC Oe. l ).O�
P[nMf oe.ze.o+
07.12.o
PPopND os.za.w
ena�wq
ae.ss.0
PROPOSED PLAN GENERAL NOTES:
1. ALL D/MENS/ONS ARE TO OUTSIDE FACE OF STUD A7
EXTERIOR WALLS OR FACE OSS STUD E INTERIOR WALLS
OR TO CENTERLINE OF POSTS. U.N.O.
2, GR/D ONES ARE TO OUTS/DE FACE OF STUD ATESTER/OR
WA15, CENTERLINE OF POSTS CENTERLINE OF DEMISING
WOR EXTERIOR FACE 0 CONCRETE FOUNDATION UD'.
J. NEW EXTERIOR WALLS SHA1 BE 2xl AND 2x4 STUD FRAMING
AT I'-40L.W/ 3/a AR SPACE BETWEEN STUDS.(UDNJ TO
MATCH EX/STING CONSTRUCT/ON.
4. NEW INTERIOR WALLS SHALL BE 2x6 WOOD FRAMING AT
I' -a OLJUDNJ 2x4 WOOD FRAMING TO WOOD
WHERE
REQUIRED TO MATCH EXIST/NG CONSTRUCTION.
5. DIMENSIONS AT EXTERIOR DOORS AND WINDOWS APE TO CENTERLINE.
SIZES ARE BASED ON CASE W!N(XJWS.CONTRACTOR IS RESPONS/BLE FOR
M UFA0TURER TO PR_DEFSHOPRORAW/NGS/PFOB I FROV RIOR
TO FABRICATION AND INCLUDE TEMPERED GLASS WHERE REQUIRED BY CODE.
6. PROVIDE SOUND INSULATION /N WALLS, FLOORS AND CEILINGS OF ALL
Pll'EEO BE WRA PED W MRS INSUL4T/ON /NG.
7. SEE AO SERIES FOR INFORMATION ON WINDOWS AND DOORS.
8. DATUM ELEVATION KXY-0'EOUALS EXIST/NG HOUSE TOP OF
PLYWOOD C UV/NG EOUAUNG S?E ELEVATION /0375 TDP
9. W/THR H?ECTU ROR INGS PR/OR TO NEW F ANG AND NOTNF S
ARCHITECT OF D/SCREPANC/ES.
0. CONTRACTOR TO COORDINATE FINISHES SPECIFIED WITH INTERIOR FINISH
SCHEDULE PR/OR TO ORDERING AND INSTALLATION OF FINISHES.
CONSTRUCTION KEY:
NEW EXTERIOR WALL
TO MATCH EXIST/NG
CONSTRUCTION
NEW 2X INTERIOR WALL
TO REI NG CONSTRUCTION
`D b
17'-0•
Zy VJF. =o I VERIFY TO BE EQUAL
0
�w3� ao31 _______________________
oWol Wal �---------- --------- ---- -------
-
----
oW�l
mW� m Wi LF
Utica! Uti WI 2 ROSIM.
__________________�__ TATE siD DEGREES PROVIDE EXHAUST FAN
I i Ap• a.00KMSE LOCATION TBD zII
-----------1'- I • i
: „ / 2 • � ,
WOOD STORAGE -L- 1, �✓BBA. E WrAlE90 DW -7
„RE: INTERI�R SPEC.
_ STEEL WOOD
1 .. 1,. _ _ _ _ _ _ - -_ __-__- __ STORAGE BINS /N
w 1 W000 FIRE LACE _ - � -'- -'- � � � J -
r
1 ' ' G A L A M B 0 S
1 ARCHITECTS INC.
F7 i ' OUTDOOR DINING
CENT OF COLUMN , , _ - - _ _f_ - - - -'- - - - -'- - - - -'- - - - -'- - �'- - - - nt2 _ 300 D AABC
TO BE CENTERED j o App ASPEN, CO B 161 I
ON 2x6 EXTERIOR i ' IO ' I' w e J/ (970) 429-1288
1 1 . • ,
FINISH FL00R l�
2 ' EL/Od-11/2'V1F.
-J' ,STEELY TRELLIS, ABOVE
RE:STRU TUBAL FOR SIZES
Ir�i RE:7/A0 FOR TAPPER 7 TD. PLYWOOD MECH. LOWERED
EL 99'-l0 //2'V1F. FRESH AR VENT - Ld
/b Lda - ...,_ _ _ • _ _ , _ _. . _ _ BREAKFAST OLBREAKSfS SEA ABOVE DOOR O ----
w 8'J 3/8 • -' ' ROOM RE: 12/AOJ7 THOU RUCTION
118 VENT PER !RC1
w ' GAS APPLIANCE FIREPLACE - 1 O
' INSTAL PER MAN'F SPECS - g_/(T-
�' • I VENT PER IRE. 1112
MECH.
0 115 Q
'----------'--i /y O
1 1 .•v ^., IF Q Z� LL J
0
3 w O w°
O DESK -- .� OEXISTING HATCH /o �---_I O bLLI Z
GARAGE n LUL W
CODE APPROVED 114 v l'� 1 ITS i LL LL
- - _ HANDRAL o i La (n
RAS REF. '�- - - ^ r--- W \ 'i
F/N/SH FLOOR it 12 _ sO Q
EL /OD'-11/2'VJF. _ _ _ _ _ _ _ _ _ STAIR /,y Ap.� J / `
113 U Z
I—I ; TA. PLYWOOD CLOSET O O
--- --- •L -J- - E-1111- 'VJF. m O O
`^ RE:
FLOOR ASSEMBLY RD. O
D REF. FAMILY FINISH FLOOR U
i -- _ _ ----- ;OHWS 1t0 1 U
RE�:yINTER/0 TA.PLYWOOD \ L / Z
U N/fL LLJ
FOR HTf�G 111 Bf fL/0Y-2' T /
w WEN nz ll3 FLOOR SEM NR.Y 1 -
---------- KITCHEN zIr O OY
117 ALfiGN DN MUD ^C
lH VENT PER /R6 112 r---- LL
FAMILY PWR. rd
i•�
STEE ,WOOD W O N - 109 /ro 1
r----
zs
a-� 3/4 ' Ap.l 13—
- - HANG �I�.o rota u�iE
OJ.
->
PANTRY � 2x4 WALL VENT PER I.R.C. 7
rnNA+o
/N/v AS APP FIREPLA:E - 2 rowrt oe.ol.w
S�q� PER MAN'F SPECS - m _
VENT PER I.R.C.I.R.C.EXISTI G F. VENT PER /RL. se W
J
MECH. a 6'- 5/8 ' A63ooW
VJF. 4
to BUILT-IN
Q I HOUR GUEST BATH FINISH FLOOR rE""nr O°•zp °'
CONSTRUCT/ON VESTIBULE VEMAR ARP EL 100'-II/2'VIF. Pn"ow�aE 0714O
THROUGHOUT - - � OENT t08EE
VENT PER /RC i PRR HEATIOTUBING w lw o1.-
RE:7/A017� O TD.PLYWOOD
PROpUCIIOM OG.Y3.W
E L 57 L i EL /00'-0' '
WOOD EEOOER i�� - - _ _ - _ _ - - --Fjl+pR' EE WOODR 6 TUB BUILT-IN
N_ RE. ORAASSEMBLY
N
O C ,
w 5'-2 3/4 ' S' -B I/2
'- O ARP NORTH
- - - - - - - `- - - - - - GUEST BEDROOM
105
1111 PARTIAL ENTRY
-.1ti J -- - - - - - - - - - - - - - - - - - - - - - - - -
/A LEVEL FLOOR PLAN
EQ. E0.
PROPOSED PLAN GENERAL NOTES:
I. ALL OIMENS/ONS ARE TO OUFSlOE FACE DF STUD AT
EXTERIOR
W. OR FACE OF STUD AT INTER/OR WALLS
OR TO CENFERLINE OF POSTS. UAD.
2. GRID LINES ARE TO OUFSIDE FACE OF STUD AT EXTERIOR
WALLS OR EXTERIOR FE�O�CCONCREfE FOUNDATION UDN.
3. NEW EXTER/OR WALLS SHALL BE 2x6 ANO 2x4 STUD FRAMING
AT Y-40L.W/ 3/4 A/R SPACE BETWEEN STUDS, (UDNJ TO
MATCH EXISTING CONSTRUCTION.
4. NEW INTERIOR WALLS SHN1 BE 2x6 WOOD FRAMING AT
YZo-C' D T 2x4 WOOD FRAMING TO BE USED WHERE
REQUIRE TO MATCH EXISTING CONSTRUCTION.
5. DIMENSIONS
AT EXTERIOR DOORS AN WINDOWS ARE TO CENTERLINE.
SIZES ARE BASED ON CASE WINDOWS.CONTRAS A /S RESPONS/BLE FOR
MANU-A URER TO PROVDEFSHOPRORAWINRSFFOR IAPS# PRIOR
TO FABRICATION AND INCLUDE TEMPERED GLASS WHERE REQUIRED BY CODE.
6. PROV/DE SOUND /NSUCAT/ON /N WALLS. FLOORS AND CEILINGS OF ALL
�P/I'��0 Bt -WRAPPED W/R25 NSU�[.AT ONT/NG.
7. SEE A/0 SERIES FOR INFORMATION ON WINDOWS AND DOORS.
8. DATUM ELEVATION IOY-O EQUALS EX/STING HOUSE TOP OF
PLYWOOD O LN/NG EOUALJNG SITE ELEVATION /0375 NJFJ
9. CONTRACTOR TO COORDINATE /A?ER/OR DRAW/NGS BY MICHAEL ME/NERS
WITH ARCH?ECTURAL DRAWINGS PR/OR 70 NEW FRAM/NG AND
NOTIFY
ARCHITECT OF DISCREPANCIES.
/O. CONTRACTOR To
COORD/NATE FINISHES SPECIFIED WITH INTER/OR FINISH
SCHEDULE PRIOR TO ORDER/NG AND /NSTALLAT/ON OF FINISHES.
CONSTRUCT/ON KEY:
NEW EXTERIOR WALL
TO MATCH E,,,_, G
CONSTRUCTION
NEW ZX INTERIOR WALL
M� EXISTING
OI R /MAI CONSTRUCTION
C00€ MPRO✓ED
HANuuRAIL
RE Ell SP!
STM 01
VA
w
/4'-7 3/4 '
!q -B 1/4
j.q
W
- - - - VJF.
U
al
7'-4 5//6 '
EQUAL
EQUAL
- -
WOOD WOOD
QW
GALAMBOS
ARCHITECTS INC.
300 D AABC
ASPEN, CO 81 61 1
W
'o 70) 429-1286
j?
U
2h
W
U)
WOOD -,0
.
/4'-7 3/4 '
!q -B 1/4
- - - - - - - - - - - - - - -
- - - - VJF.
7'-4 5//6 '
EQUAL
EQUAL
- -
WOOD WOOD
V
Z�
I
___________
I
I
,
w0
Q O
I
/J
Zo
H
RE. /1/40J7 FOR BARSTEE
Z
Ld
D
FLOOR ASSEMBLY 121
U LL
.W
' , , ' ;
MASONRY. GAS LOG F/REPLACti -
MECH.SUB-CONTRACTOR DW
i
W
Q
'
VENT, PER I.R.C.
TO PROVIDE VENT/NG
W
Z
12�
AND FRESH A/R MAKE-UP ,ICE
•
FRESH'A1RI
fT
j
1��-�,—�II"
GAS APPLIANCE FIREPLACE -
INSTALL PER MAN'SPECS -
" - - - - - - - - - - - - - - - - -LIBRARY-"
104
STUD RE: II/AO.17 FOR
VENT PER I.R.C.
(�
-2x4 WALL
FLOOR ASSEMBLY
,
la
_-----_-
v —__
__—__-_______---
---------------------
O
Z
15'-0'
r
r-
I'
ALCOVE r0Ld
-I BE 2X6 FRAMING
Q SEE A24NE
VIF.
l
(7)STEELTEES ABOVE ,
EQUALLY SPACED I pf
RE:I/A10J4 FOR 1`jAPPER,
3'£ 6'-0' 3'£
ove
R_F_r STRUCTURAL � _ _
E0. E().
-
REN
w.I3.w
ae.ol.w
13'-7'114 '
Now
RE: 1I/AI0J7 FOR
EQUAL EQUAL
PFAMIf
PKIU(iE
PFAMf
veeoow
PACJ(ME
PHIOINO
s}m :nor oev
PPOOIICIION
oe o7 w
oe.l7.w
Oe.ze.w
REF."
DRWS'
FLOOR ASSEMBLY
W000
,SI -EEL-________ - - -
_ _
DINING
EE FLOOR Cp C tp FUER
E L
-------
t20
rRE11101
- - - - - _ -
J
FOR D
ALIGN
N
GALLERY
FLOOR ASSEMBLY
103 ,
PASSAGE
b b
ON
LMNG
rREFER TO
FORORADlA'Y7-
t f— EXISTING
102
HEAT FLOOR
ASSEMBLY
WALL ABOVE
/,� 15'0':
„
VJF.,
f„ BUILT -!N
K CASEW
WOOD
EE Fl_00R
'TEFL
RE !INTERIOR ELEVATIONS
, "
j;i
f--
f' UNEN CLOSET
122
CUSTOM STEEL AND �
,"
FINISH FLOOR -- - - - --
'
GLASS DOORS
' ,
EL/OY-5'VJF.
TD. PLYWOOD
EL/0Y-r VJF.
,
2
--------------------------NEW
UNDERFRMIED
!'£ /4'-/0 1/2 '
ERT/FIED MASONRY WWDBURN/NG
CEILING ABOVE
VJF. N
6pEpNOl7gqppT����. \
FIREPLACE -
VENT & SEAL PER ALL APPLICABLE
HEATRFL()bR ENTRY
AS101 O
CODES
RE: INFERIOR ELEVATIONS
DN
= W000
STONE
BUILT -!N WOOD
STORAGEF!N/SH
FLOOR
"
vfi EQ. EQ.
_ _ _ _ _ _ _ _
RE:INFERIOR ELEVATIONS
EL/Od-I !/r VJF.
TD.PLYW00'
/
'
ELLI
RE. 11140.17 FOR
I Ef
e
FLOOR ASSEMBLY
j
'
O
I
(4) STEEL TEESABOVE
DIRECTION NORTH/SQUTH
,
'
" 'S - - - - - - - - - - - - -
- - ------------5
EQUALLY SPACED.
RE:6/AIOJ5 FOR. TAPPER j
RE: STRUCTURAL' j
O ALCOVE TO
O
BE 2X6 FRAMING
,
M ' FACE
Ap j
----
- --- - - - --,
OF
j (0 STEEZ TEE ABOVE
OIRECTI4N EAST WEST
-1----
.
- - --.--------
(W,STEEL TEES ABOVE
- -- EO(IALLY SeACED
,----- ---,
I
--L
' - -
I, 2 3/4 '
- - - - - - - - - - - - - - - - - - - -
I
- -
RE- 3/A1014 FOR TAPPER
1
_ -
5'-4 114' -9 //4 -9 1/4 ' F -T
GALAMBOS
ARCHITECTS INC.
300 D AABC
ASPEN, CO 81 61 1
W
'o 70) 429-1286
j?
U
2h
W
U)
WOOD -,0
.
W0
zQ
Q O
ALIGN
WOOD WOOD
V
Z�
fY J
LL
4 p
w0
Q O
Lu C)
W
r-7 //2
3
Z
Ld
,
I
I
U LL
RPET
' , , ' ;
MASONRY. GAS LOG F/REPLACti -
i
W
Q
'
VENT, PER I.R.C.
�
Z
O
•
FRESH'A1RI
fT
j
" - - - - - - - - - - - - - - - - -LIBRARY-"
104
STUD RE: II/AO.17 FOR
W
O
Lo Z
-2x4 WALL
FLOOR ASSEMBLY
,
O
_�
Z
r
r-
I'
ALCOVE r0Ld
-I BE 2X6 FRAMING
l
(7)STEELTEES ABOVE ,
EQUALLY SPACED I pf
RE:I/A10J4 FOR 1`jAPPER,
ersuEo FOR
ove
R_F_r STRUCTURAL � _ _
E0. E().
-
Pwueo
PF11N1!
w.I3.w
ae.ol.w
13'-7'114 '
Now
oe o3.w
EQUAL EQUAL
PFAMIf
PKIU(iE
PFAMf
veeoow
PACJ(ME
PHIOINO
s}m :nor oev
PPOOIICIION
oe o7 w
oe.l7.w
Oe.ze.w
7. l i.w
07.12—
-23—
0 23.w
aa.23.w
} RE( SFRUC�URAL _ _ _ _ 1_ , _ _ _ , _ _ _ ,L
I
2 3/4 'o , q -q 3/4 • 9-4 3/4 ' _ _ .r2 3/4
UW�i iW�
QW1
W o I EQUAL EQUAL ' o
NORTH
PARTIAL ENTRY LEVEL FLOOR PLAN
�� va•
Lu v ,. ,........ I
-----------------
' K_(7) STTJEJE,L, TTEECE�•ABOVE•
4'-8 3116 ' I R(': STR U�4 R/K FOR SAZP.�
I FACEOF
1 --- ---- --
_ STUD
/P I STUD W AME
N/D ZY4R .
INTERIOR W/TH 3/4'AIR SPACE
-EWAL 9 3/4'OVERALL
M '
PROVIDE RA IANT HEAT
N TUB/NG UNDER PLYWOOD
RE: S/Ipn FOR FLOOR
ASSEMBLY
fJ�
,32
--------------------
131
RE. 8// FOR FLOOR
ASSEMBLY ----------------------------
PROPOSED PLAN GENERAL NOTES:
2 3/4
1. ALL
0/MENS/ONS ARE TO OUTSI
3116 ' EXTER/OR WALLS OR FACE OF
-1' OR TO CENTERLINE OF POSTS
' Z. GR/D ONES ARE TO O'UTS/DE
-� WALLS. CENTERLINE OF PoSTS
WALLS OR EXTERIOR? FACE OF'
_ s
AIQ _I_ _ _ _ _ _ _ _ _ _, J. NEW EXTERIOR WALLS SHALL
AT Y-4'OC.W/ 3/4 AIR SPACE
N��PS TER I MATCH EXISTING CONSTRUCTION
- ' BATH lM 4. NEW INTERIOR WALLS SHAM B
I'40GIUDNJ 2x4 WOOD FRAMIN
REWIRED TO MATCH EXISTING
5. D/MENS/ONS AT EXTERIOR 000
SIZES ARE BASED ON CASE W
MANUFACTURER TPER
ROMV/DE F
TO FABR/CAT/ON AND INCLUDE
6. PROVIDE SOUND INSULATION /N
ROOMS•ALSO SURROUNDING ALL
MASTER BATH ALL PIPES TO BE WRAPPED W
SWIM �
7'-3 3/4 '
DE FACE OF STUD AT
STUD AT INTERIOR WALLS
UN.O.
FACE OF STUD AT EXTERIOR
CENTERLINE OF DEMISING
CONCRETE FOUNDATION UD.N.
BE 2x6 AND 2x4 STUD FRAMING
BETWEEN STUDS.(UDNJ TO
.
G TO BESU FRAMING
D WHERET
CONSTRUCT/ON.
IS
AND WINDOWS ARE TO CENTERUNE.
INDOWS.CONTRACTOR /S RESPONS/BLE FOR
ACTURER SPEC/F/CAT/ONS. WINDOW
HOP DRAWINGS FOR MPROVAL PR /OR
TEMPERED GLASS WHERE REOU/RED BY CODE.
WALLS, FLOORS AND CEILINGS OF ALL
MECHANICAL DUCTING.
/R25 INSULATION.
7. SEE .NO SER/ES FOR INFORMATION ON WINDOWS AND DOORS.
8. DATUM ELEVAT/ON /Q7-0'EWNS EXIST/NG HOUSE TOP OF
PLYWOOD m WING EOUVJJNG SITE ELEVATION /0375 NJFJ
9. CONTRACTOR TO COORD/NATE INTERIOR DRAWINGS BY MICHAEL MEINERS
WITH ARCHITECTURAL DRAWINGS PRIOR TO NEW FRAMING AND NOTIFY
ARCHITECT OF DISCREPANC/ES.
l0. CONTRACTOR TO C00RDINATE FINISHES SPECIFIED WITH INTER/OR FINISH
SCHEDULE PRIOR TO ORDERING AND INSTALLATION OF FINISHES.
CONSTRUCT/ON KEY:
NEW EXTERIOR WALL
TO MATCH EX/ST/NG
CONSTRUCT/ON
NEW 2X INTERIOR WALL
EX/ST/NG CONSTRUCTION
TO REMAIN
16'-7 //4 22'-4 //4
7'-0' 7'd r-3 5/
ALIGN I _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Li DIL
I I I I { ,--F-� /
Ep
T rJe N — EnIX NE SPACED ABOVE
R •7/A/OJ FOR TAPP R
a PRL
STER N4C
133
9 3/4 ' &oR RE: RUCTURULRFOR SZE o� BED 01
BUILT-IN
�p MEDICINE CAB/NET
VJF. EQUAL 13'-2' EQUAL EE
ASSEMBLY FOR FLOOR
130 1
CARPET TILE 7
I I I
'---- ---- -- -- - - - - I -- - -- -- ---- ---- -- ----
I-
° ° RF: STRUCTURAL FOR �IZE
NN
'
p•
I
!
BEDROOM 03
_ . _ ... -.
®
3'$
134
� w
' T,D.PLYWOODy:L-
'VE A(4GNW1 °
P
W h
RE: S//017
RE. 4110J7 FOR
° PF.OF PASSAGE Y
FOR FLOOR
ASSEMBLY
BUILT-IN
WITH GLASS SHELVES
FLOOR ASSEMBLY
N
FOR TOWEL STORAGE
gA 01
ry�
a.
11A
° SUN ROOM
OFFICE
N n
PER IRC
R�g FOR FLOOR
137
C£IUNG AABBROVEAMEO
BATH o3 i
.
_ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _
1
I SM FOR FL00�
E
FL�R� ASSRik
T7
fie
ASSEMBLY
l/2 '
LA
FESPECS
C
-
I N Sq�LANCE
PER RRL
2
---, ---; -- ;---- ; --- ;
�UOSET 03'
--
' w
MASTER BEDROOM
131
s1 3'
'
FOR FLOOR
R
'
PASSAGE
ASSEMBLY
ASSEMBLY
3'-5 318 '
y
123
ALCOVE/NG
2X6
FACE
STUD Al
1 m
-1t -I
ATO.
Jr
/
2 3/4 °_
11
1 2 3/4
,
MASTER
t__
1 _ _ _ _
_ _ _ _ j
BU/LT-IN
H
BEDROOM
1 Ol STEEL TEES ABOVE
w a
i
11 T� L SSTHO
9 3/4 ' &oR RE: RUCTURULRFOR SZE o� BED 01
BUILT-IN
�p MEDICINE CAB/NET
VJF. EQUAL 13'-2' EQUAL EE
ASSEMBLY FOR FLOOR
130 1
CARPET TILE 7
I I I
'---- ---- -- -- - - - - I -- - -- -- ---- ---- -- ----
I-
15'-8 I/2 '
° ° RF: STRUCTURAL FOR �IZE
NN
'
p•
I
!
S_UN•ROON
_ . _ ... -.
®
I
I
� w
' T,D.PLYWOODy:L-
'VE A(4GNW1 °
P
W h
RE: S//017
,
° PF.OF PASSAGE Y
FOR FLOOR
ASSEMBLY
BUILT-IN
WITH GLASS SHELVES
'
N
FOR TOWEL STORAGE
gA 01
ry�
a.
11A
° SUN ROOM
OFFICE
N n
PER IRC
R�g FOR FLOOR
137
�\
ASSEN/R�
E 6
.
_ _ _ - _ F(ED04R AISEMBLY 7 • - • ' °
_
E
E
FL�R� ASSRik
T7
2x6 WALL
l/2 '
ICRO,
.
ra
---, ---; -- ;---- ; --- ;
�UOSET 03'
--
3/8
PASSAGE
3'-5 318 '
y
123
15'-8 I/2 '
6 '
s
7'-8'
p•
I
!
S_UN•ROON
®
I
I
,
� w
w 1z7
P
W h
RE: S//017
RE: 51/OJ7
o'
FOR FLOOR
ASSEMBLY
BUILT-IN
WITH GLASS SHELVES
p2�x�4 WWALL
RE: ST 0CTURAL
N
FOR TOWEL STORAGE
gA 01
ry�
a.
11A
OFFICE
N n
PER IRC
R�g FOR FLOOR
�\
ASSEN/R�
E 6
/4'-/ 314 '
E
FL�R� ASSRik
T7
2x6 WALL
EQUAL
u4•= r -D^
WALL
W
DN RISERS
V
OOR DN
/z
I
I
I
I
VJF.
.Y LEVEL FLOOR PLAN
NORTH
GALAMBOS
ARCHITECTS INC.
300D AABC
ASPEN, CO B 1 61 I
(o 70) 429-1266
W
0
W O Zjr
U J tyo
W O w ov
O �z
U(L
oZ
O O
_W Q '' ^1 C)
Y/
O oY
Z �' a -
W
6aum Foa wre
PitlCmO 06.13.0'1
rmNrt oe.ol.o+
IIo� ae.o3.o'1
v[w�r ae o� a
oe.ls.o+
�� oe.ze.oa
wwoow
PK1tME 0712.W
PPoOIIq 07.23.0.1
OSET 01 o
d CLOSET 02
� w
w 1z7
RE: S//017
RE: 51/OJ7
FOR FLOOR
ASSEMBLY
FOR FLOOR
ASSEMBLY
BUILT-IN
WITH GLASS SHELVES
FOR TOWEL STORAGE
gA 01
ry�
BUILT-IN BED 02
MEDIC/Nf CABINET
11A
1�
VENT PER
PER IRC
R�g FOR FLOOR
�\
ASSEN/R�
E 6
EQUAL
u4•= r -D^
WALL
W
DN RISERS
V
OOR DN
/z
I
I
I
I
VJF.
.Y LEVEL FLOOR PLAN
NORTH
GALAMBOS
ARCHITECTS INC.
300D AABC
ASPEN, CO B 1 61 I
(o 70) 429-1266
W
0
W O Zjr
U J tyo
W O w ov
O �z
U(L
oZ
O O
_W Q '' ^1 C)
Y/
O oY
Z �' a -
W
6aum Foa wre
PitlCmO 06.13.0'1
rmNrt oe.ol.o+
IIo� ae.o3.o'1
v[w�r ae o� a
oe.ls.o+
�� oe.ze.oa
wwoow
PK1tME 0712.W
PPoOIIq 07.23.0.1
POOL HOUSE
ROOF PLAN
Ile. P-0'
AAe
lr-7 //2 0-4 112 15-1 114
l6' -P
i
i I 6'-3 //2 ' 9-9112 '
I I I I
I I II
1 _ -
P1
Lsr,rE WALL I Oo ! SITE WALL
Z I EXTERIOR j:iE1W
�j
SSL/ PI03SHOWER TONE COLOREDpgOVE
_ ��
- b - - - - - - - --- - - -
' 1 � •Dw' REF. ,' �'
/ BUILT-IN CABINET
AND COUNTER TOP
lO'-0• 11'-7 1/2
+ 1 �1r, RD. N
EXERCISE
M 1 1
1 + ,
F/NISH FLOOR ! MIX
Asw i EL•l04'-2 3/4 i 4e2 m
+------ 1 -1---------+--'-------- O tP
Pn , 1 I fL•l03'-Il3/4 ! 3
2 a 1 ABOVE
b M I !
IAIO.12 / �
Ile
1 ;
----------- ---------
r_ _ - - - - - - aU
PB ABOVE PA ZD p41
A+D.re a� l� !SURFACE MOUNTED L?
I + 1 nom• I UGHT iG
I 1 i ROTATE80 + i ROTATE 917 I
, { DEGREES i
couNmr- - 'COUN+ER 6'-1/4'
n +
P3 1--------�----- ° '"�-=--L----RISE
a4----- -_-________----__-__-__-__-__ ---------------------
-�- - - - - - - - - - - - - - - - - - - - - - -+ - -
4112 ' 0-4 I/2 ' _ _ - - - - - - 15'-1I/4 '
p _
A+D.12 I 27'-10 //4
39'-11/4
PD PC A+•+ PB A4w PA
.ve
PROPOSED PLAN GENERAL NOTES:
I ALL DIMENSIONS ARE TO OUTSIDE FACE OF STUD AT
EXTER/OR WALLS OR FACE OF STUD AT INTER/OR WALLS
OR TO CENTERLINE OF POSTS. UNA.
2 GR/D LINES ARE TO OUTSIDE FACE OF STUD AT EXTERIOR
W OR EATER/OR F�E�O�CC NCRETE FOUND TION UAN.
3. NEW EXTERIOR WALLS SHALL BE 2x6 AND Zx4 STUD FRAY/NG
AT 0iW/ 3/4•A/R SPACE BETWEEN STUDS.(UANJ TO NORTH
MATCH EX/STING CONSTRUCTION.
4. NEW INTERIOR WALLS SHALL BE 2x6 WOOD FRAMING AT
l'40CIUANJ 2x4 WOOD FRAMING TO BE USED WHERE
REQUIRED TO MATCH EXISTING CONSTRUCT/ON. POOL HOLIOE
5. DIMENSIONS AT EXTERIOR DOORS AND WINDOWS ARE TO CENTERLINE. �� FLOOR PLAN
SIZES ARE
BASED ON CASE W/NDOWS.CONTRACTOR /S RESPONS/BLE FOR + /
ROUGH OPENINGS PER MANUFACTURER SPECIFICATIONS. W/NOOW
MANUFACTURER TO PROVIDE SHOP DRAW/NGS FOR N'PROVAL PR/OR
70 FABRICATION AND INCLUDE TEMPERED GLASS WHERE REW/RED BY CODE.
6, PROVIDE SOUND /NSULAT/ON /N WALCS,FLOORS AND CEILINGS OF ALL
ROOMS•ALSO SURROl1NDING ALL MECHAN/CAL DUCTING.
ALL P/I'ES T, BE WRAPPED W/R25 INSULAT/ON.
7. SEE NO SERIES FOR INFORMATION ON WINDOWS AND DOORS.
B. PLYWGOD B LIVING EW�N�S EEE AT/OHOUSE
10375 NJFJ
9. WITNH CHRTEt URACRD NG PR/OR DRAWINGS
0 NEW FRYING AND N NFEYRS
ARCHITECT OF D/SCR P,aNC/ES.
I0. CONTRACTOR TO COORDINATE FINISHES SPECIFIED WITH INTERIOR FINISH
SCHEDULE PR/OR TO ORDERING AND INSTALLATION OF FINISHES.
W
GALAM BOS
U)
ARCHITECTS INC.
Z)
�)
300 D AABC
U
ASPEN, CO B 1 6 1 I
J
WO
(Q 70) 429-1266
O
Ld NZ
W
W
U)
Z)
�)
=o
Q
U
�o
J
WO
w°
Q0
Ld NZ
W
2
U
" WKS
Q
eIL.Ir�
O
o
o�
o
W Q
OoY
z
W
O Lij
J
�svuum iGR
PRICING
PERMR
NOG
PERMIT
PAGNAGE
PERMR
w2naw
PACNAOE
PRICING
ew1E
03.13.04
-01.04
oe.03.04
M.07-
oe.17.04
m.2e.w
07.12.04
07.23.04
TELEPHONE & \
ELECTRICAL LINES
\ I \
e /
e �
e
0
�5
-- — — DRYWEL 00
NEW CHIM Y
AND FIREP ACE
N 00*39'00'W \ \ \ \
x.._._....._..._ .�..�.- � \ EXIS :SNC BUILDING ENVELOPE
408.75. .-----..
NEW ROOF
EXISTING
FRENCH DRAIN \ \ \ \ \ \ \
i + ` EW SPA NEW SPA
NEW ROOF
XISTING �OOF
T.O. FINISHED
'OR IRE: YC L LIMITS)
`� - \ WALL = SITE FIR \ \ \\ \\ NEW FREId(- DRAIN l
OR HEIGHT\L!MITSJ � �--""- �j
I \ ELEVATION: \ \ \ \ CONNECT T' _XISTING DRY WELLS '
I10'-4 3/4 IT \ \ \ \ \ /
I `� '� \ ` \\ ENT R\ OE suoo 1- - c T.O. FINISHED \ \\ \ \\ I
NEW WALL = SITE \
\1 ELEVATION: NEW AIA l \ `I INDUSTRI S
� � 1121-10 3/4" UNDERGROUND
' -r""
'+ CUSTOM - NEW AIA 1 \ POOL \
' SKYLIGHT IINDUSTRIES J { I VAULT
1
! i 1 GLASS ROOF 1�
i t 1 85'-0'
NEW R00 SOLAR
5,- 114' PANELS
, EXISTING ROOF , G\,0 NEW POOL
RIDGE (RE: ZLEVATIONS
ICE : `� I
FOR HEIGHT LIMITS)
I
1 �+ NEW SKY LIGHT -
IN NEW GABLED
ROOF NEW SKY LIGHT
IN NEW ROOF
NEW AIA INDUSTRIES ) { l
GLASS COVERED
TRELLIS
+ ;
101 T.O. FINISHED
' + l WALL = SITE
ELEVATION:
112!03/4 i/,, / �/ ��•
DRYWELL
EW
j RODF ; EXISTING ROOF ' \ SLOpE
t O.
�
RIDGE
E: ELEVATONS
HE S
\
\ ' I T.O. FINISHEQ
WALL = S/TE11 ,
ELEVATION: I
110'-¢ 3/4"oo
CL
6j�/
1 NEW CHIMNE\ \ '
NEW FRENCH DRAIN /
AN FIREPLACE, _ ,'� � \ � \ CONNECT TO EXISTING DRYFLLS
1 r.
/\ 1 NEW CONCRETE APRON -
/
EXISTING
FIRE HYDRANT
1
1
1
1
1
i
1
EXISTING
ELECTRIC METER
EXISTING
TRANSFORMER
EIV Efi AL SE-- PLAN NOTES:
SITE PLAN INFORMATIUS BASED ON THE SURVEY PREPARED BY
ASPEN SURVEY ENGINNS, NC. DATED 04.27.04. ARCHITECT ASSUMES INFORMATION
PROVIDED BY SURVEYCIS ACCURATE AND ARCHITECT IS NOT
RESPONSIBLE FOR INAURACIES, ERRORS OR OMISSIONS BY SURVEYOR.
'. CONTRACTOR TO TAKERE�T CARE TO NOT DISTURB VEGETATION OUTSIDE OF
OF ACCESS AND BUILIG EVVELOPE. ANY DISTURBED VEGETATION SHALL BE
RESEEDED OR PLANTI WrH NATIVE VEGETATION.
T. CONTRACTOR TO VER/fWITN LANDSCAPE ARCHITECT TREES TO BE REMOVED AND
TREES TO BE TRANSANTED, AS REO'D.
51TE MN
1" = 20'
RE. T2.7 FOR;NOW L -LT
AREA CALCULI IONS
G A L A M B O S
ARCHITECTS INC.
300 D AABC
ASPEN, CO 8 161 1
(970) 429-12a45
o
C' a
WujI' TP
U a
0
W. w
O
0 U
Ld 7zQ
0 Qo
Z
� J
--�
�eo
Ld 0 wU
Q 0 WZ
CL U CLLJ
z o
�..o
C� o Z
C° o
0
Lli Lo
0 of
Z CL
LLJ
ry
ISSUED FOR
PRICING
DATE
05.1 3 04
PERMIT
06-01.04
HOA
06 03 04
PERMff
06 07 04
WINDOW
PACKAGE
06 1 7 04
PERMIT
06 28 04
WINDOW
PACKAGE
07 1 2 04
PRICING
07.23.04
A" r) i //, T/l r A /"V / / A / r/ / 7-l7 A 7-/nr-) / /A// T
INFIL TRA TO/
BED PLAN
" SDR 35 P VC NrW SEP TIC TANK
LEVEL HEADER PIPE
CLEAN-OUT DETAIL-
'--- 3" TEE
)NCRETE
IPPOR T
XLAR
FLOW
FROM
HOUSE
J" SWEET AIR CHARCOAL FILTER
o (OR APPROVED EQUAL)
N
SANDY TOPSOIL VARIES
FROM 12" AT CENTER 4" AIR VENT
TO 2" AT EDGES
SEED TOPSOIL
ILI
itl
N - -di -
SA/VD STRA TA
4" SOLID PVC
STUBBED INTO UNIT
2" OF SAND OR SUITABLE ON-SITE --/
MATERIAL APPROVED BY THE ENGINEER
AIR VENT DETAIL
NOT TO SCALE
25'
2.5' 1 5' 1 5'
5'
NOTES:
1. ALL MA TERIALS, INS TALLA TION PRACTICES, SETBACK REQUIREMENTS, ETC,
SHALL COMPLY WITH THE PITKIN COUNTY INDIVIDUAL SEWAGE DISPOSAL
SYSTEM REGULA TIONS.
2. THE E. TA. BED SHALL BE CONSTRUCTED SO THAT THE BOTTOM IS LEVEL
4-/--0. 1' PLACE BED IN NATURAL GROUND; NO PORTION OF THE BED SHALL
BE PLACED IN FILL.
3. PROVIDE ADEQUA TE SURFACE & SUBSURFACE WA TER DIVERSION TO ASSURE
THA T RUN-OFF DOES NOT ENTER THE EVAPO- TRANSPIRA TION -ABSORPTION BED
IF SUBSURFACE WA TER IS ENCOUN TERED, NO TIFY ENGINEER.
4. STONE SHALL BE 1/2" TO 2 1/2" SCREENED ROCK.
5. SAND SHALL BE 0.04 TO 0.28 MM EFFEC TI VE SIZE WITH A UNIFORMITY
COEFFICIENT OF 4 OR LESS PROVIDE SIEVE ANAL PSIS TO ENGINEER FOR
REVIEW.
6. THE RECOMMENDED BED SEEDING IS SAL T RESISTANT FESCUE A T 4 TO 6 LBS. PER
1000 SQ.FT ALL OTHER AREAS DISTURBED BY CONSTRUCTION SHALL BE RESEEDED
WI TN NA TI VE GRA SSSS TO PRE VEN T EROSION.
7. THE LOCA TION OF THE BED MA Y BE ADJUSTED IN THE FIELD TO BETTER FIT
THE SITE, PROVIDED ALL SETBACKS ARE MET. CONTRACTOR SHALL VERIFY
L A YOU T ACCOMMODA TES Sl TE SL OPE.
8. DRAIN HOLES IN 4 " PERFORA TED PIPE TO BE A T 60" SPACING (2 HOLES
PER SPACING, 1/4" DIA. LOCATED DOWNWARD) OR ASTM 2729 PERFORATED PIPE.
9. 4 " P VC TEES SHOUL D NO T BE GL UED TO ENA BL E OBSER VA TIONS OF WA TER
LEVEL IN SYSTEM AND TO REMOVE EXCESS SALTS ACCUMULATION OR SURPLUS
WA TER, IF NECESSAR Y
10. USE RISERS AS NEEDED TO BRING SEPTIC TANK ACCESS HATCH WITHIN 6"
OF FINISHED GRADE.
11. SDR 35 PVC PIPE OR PIPE OF EQUAL STRENGTH OR OTHER PIPE PROPERL Y
SUPPORTED TO PREVENT FAILURE BY SETTLING SHALL EXTEND FROM ALL
TANKS FOR A DISTANCE OF AT LEAST FIVE FEET (5) FROM THE INLET AND
OUTLET ENDS.
12. THE CON TRA C TOR AND 0 WNER SHALL TAKE WHA TE VER MEA SURES ARE
NECESSAR Y TO A SSURE THA T (a) SEP TlC TANK AND SEWER L INES ARE
COMPLETEL Y WA TER TIGHT, AND (b) THE SYSTEM IS TO BE INSTALLED TO
PREVENT FREEZING OF ALL PRESSURE AND GRAVITY SEWER LINES.
13 THE PITKIN COUNTY ENVIRONMENTAL HEAL TH DEPARTMENT AND THE ENGINEER
SHALL BE NOTIFIED WHEN CONSTRUCTION COMMENCES AND KEPT ABREAST OF
THE CONSTRUCTION PROGRESS SO THA T SUFFICIENT INSPECTION CAN BE
PERFORMED TO ASSURE CONFORMANCE WITH THESE PLANS. PROVIDE A
MINIMUM OF 48 HOURS NOTICE TO EACH.
14. PVC SEWER PIPE SHALL BE SDR 35 /N ALL TRAFFIC AREAS, ASTM 2729 PVC ELSEWHERE.
15. THE SURFACE OF EACH BED SHALL BE PROPERL Y MOUNDED PER THE DRAWINGS
TO ENSURE THA T PRECIPI TA TION OR SNOWMEL T WILL RUN OFF THE BE
16. SURFACE GRADING SHALL ROUTE RUNOFF AROUND AND AWAY FROM THE BEDS.
DESIGN CAL CULA TIONS:
1. EXISTING HOME (>6000 SF), USE 2 PERSONS/BEDROOM AND 130 GPCD.
2. DETERMINE FLOW.
Q (BEDROOM) = (2)(1)(130) = 260 GPD
Q (POOLHOUSE) = 10 PERSONS * 10 GPCD = 100 GPD
Q (DESIGN) = 1.75 * 360 GPD = 630 GPD
J. SEPTIC TANK:
V = 630 GPD * 1.25 = 788 GALLONS, INSTALL 1000 GALLON TANK
4. ALLOWABLE LOADING RATES:
DESIGN FOR COMBINATION ABSORPTION/EVAPO-TRANSPIRATION METHOD OF
EFFLUENT DISPOSAL.
PERC TEST RESULTS: 240 MINUTES/INCH (ASSUMED)
EVAPO- TRANSPIRA TION.- USE ET RATE OF 32 %YEAR
5. DETERMINE BED SIZE.
FOR ABSORPTION. Q = 5 * (AREA)/SQRT()
FOR EVAPO-TRANSPIRATION: Q = 32%YR * (AREA/586
6. COMBINE EQUATIONS AND SUBSTITUTE:
Q (ABSORPTION) f Q(ET) = 630 GPD
0.3227(A) f 0.0546(A) = 630 GPD
AREA = 1670 S. F.
INSTALL 25' X 68.75' BED (EFFECTIVE AREA = 1718.75 S.F.)
5' 1 2.5'
GENERAL
•
SLOP A T 2. 1
GRADE OR TO
T lS Tl
BED (TYP.)
SA
FR
D Y TOPSOIL VARIES
M !
MD
12" A T DLE
7\
11
AIR VENT (4 R
SEE DETAIL
Q'D)
T02
" A T SIDES
----
--
SITE PLAN
x
C
BOTTOM OF BED SHALL BE LEVEL _/ WASHED SAND
0.1 +, SCARIFY BEFORE PLACING SAND
\_2"SAND
4 " PERFORA TED P VC
SLOPE O'IFT. (TYP.)
BED SEC TION
SCALE: 1"= 3'
Si }'J,noC �
IMA
.W.y
EXISTING GRADE
SLOPE A T 2.• 1 MAX. TO EXISTING
GRADE OR TO BED (TYP.)
PROVIDE SWALE TO DIVERT
RUN-OFF AROUND E. T.A. BED
SLOPE A T 19' MIN. TO DA YLIGH T }
Pq PPPfP asas" �
L J. G °.
# PAS