pitkin.eh.264334301711 (2013)
� � 1TKIN CoUNT� Permit #: 006.2013.powt 4 .SITE WASTEWATER TREATN. .4T SYSTEM (OWTS) CONSTRUCTION PERMIT 76 Service Center Rd- Aspen, CO • 81611 Phone: 970.920.5070 Fax: 970.920.5374 Parcel ID #: 2643-343-01-711 Permit Issued: ®NEW CDU ❑REPAIR ❑REMODEL/ADDITION ❑TANK ONLY [-]FIELD ONLY ❑AMENDMENT Owner(s): GIM Colorado Holdings, LLC Property Address: 1365 Owl Creek Rd Legal Description: Size of Lot: 5.04 Size of Buildinq: Lot 11 Owl Creek Ranch 1296 Acres Detached Accessory Unit: ❑YES ®NO Sq. Ft. Size of Accessory Unit: The systems are designed for: 2 -bedrooms in the historic Victorian homestead. Designed By Phone #: Fax #: Roaring Fork Civil Consultants 970 - Project #: Mailing Address: Email Address: Perc Rate: 0.30 LTAR Profile Hole Depth Minimum Tank Capacity: 563 gallons C1022 Dated: PO Box 4201 Basalt, CO 81621 6 ft Depth to Groundwater or Bedrock: Minimum Absorption Area: 1,500 sq ft. Permit Conditions: Sq. Ft. 1/30/2013 ➢ 6 ft This OWTS Construction Permit is approved on the condition of compliance with the engineer design as submitted with the application and the specifications cited above. Changes must be approved by this Department and the engineer prior to construction. The OWT system is designed for the 2 -bedroom historical Victorian residence. The OWT system consists of sewage flowing via gravity through 4" SDR -35 pipe to a 1000 gallon concrete 3 -compartment septic tank with a 0.5 MicroFAST advanced treatment unit installed in the second compartment. A P-30 pump will be installed into the third compartment and will pump effluent via 2" SDR -35 pipe to a distribution box. The distribution box will distribute the effluent to 8 zones. Each zone will contain (5) 40' laterals with a minimum of 2 feet between each lateral. The system shall meet the following minimum setbacks: 10' to the property line, 25 feet to the water line, 100' to any well, and 50' to any pond or stream. This Permit must be kept on-site during installation. The engineer must do a final inspection of the installation and submit an "as -built" letter to this Department within 30 days of the final inspection, unless a longer period of time has been agreed upon, in writing. This Department must also be called for the final inspection with a minimum of 48 hours notice. Minimum horizontal distances beiween components of the system and physical features shall conform to the requirements of the Pitkin County OWTS Regulation. This Permit is conditioned upon the property owner(s) providing for regular inspection, cleaning, and maintenance of the system by qualified personnel, in accordance with the manufacturer's recommendations and the requirements of the Pitkin County OWTS Regulation. Issuance of this OWTS Construction Permit does not constitute a guarantee, warranty, or representation by the Department that the system will operate properly or will not fail. Issuance of this permit does not imply compliance with Pitkin County building and/or land use regulations, nor guarantee issuance of building and/or land use permits. THIS PERMIT IS EXPRESSLY CONDITIONED UPON COMPLIANCE WITH ALL REQUIREMENTS OF THE PITKIN COUNTY OWTS REGULATION, INCLUDING BUT NOT LIMITED TO THOSE CONDITIONS SPECIFIED ABOVE. Plans and specifications for the proposed OWTS have been reviewed and are considered satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated in accordance with the Pitkin County OWTS Regulation. This Permit will expire 1 year from the date of issuance unless construction on the system has commenced. An "as -built" drawing must be submitted and approved by EH before final approval of the system will be issued. Issued By: � 7: C?- Date: 2/25/13 Expires: A rC>- - 02/25/2014 Installer. ,0 License #: Reactivation Authorized by: 4Ckl WIC ✓i i Final Approval Issyed By: Date: New Expiration Date: ❑FrtPad bib Vti� �,.� r �� ONSITE WASTEWATER TREATMENT :SYSTEM (OWTS) CE11NR CONSTRUCTION PERMIT APPLICATION 76 Service Center Rd • Aspen, CO. 81611 Phone: 970.920.5070 Fax: 970.920.5374 Parcel IDO (available from the Pitkin County Assessors Office 2643 - 343 - 01 - 711 970-920-5100 or at www.odkinassessor.org Purpose of Permit: ❑NEW ❑ REPAIR DUE TO FAILURE [XREMODELJADDITION ❑ TANK ONLY ❑ FIELD ONLY Cost of System Repair or Remodel/Addition (approximate): $20,000 Property Address: 1365 Owl Creek Road, Aspen, CO 81611 Lot: Lot 11 Block: Filing: Subdivision: Owl Creek Ranch Property Owner(s)': Email Address' GIM Colorado Holdings, LLC owners Mailing Address: 111 East Wacker Dr. #2800 city, state, zip: Chicago, IL 60601 Home Phone: Business Phone: 'Contact information must to provided for the owner signing this application. Primary Contact Person/Applicant (if not owner): Monty Thompson Company: Thunder Construction. Contact/Applicant Mailing Address: PO BOX 4841 city, State, zip: Aspen, CO 81612 Cell Phone: 970-379-5823 Business Phone: Fax Number. Email Address: thunder@sopris.net Building Permit # (if applicaole): Lot Size (in acres): 5.010 acres Size of Building (square feet): 1296 sf Number of Potential Bedrooms: 2 Detached Accessory Unit? L] YES ®NO Size of Accessory Unit (square feet): Number of Potential Bedrocros In or Fixture List forthe Accessory Unit: Water Source: ❑ PRIVATE WELL ❑ SURFACE WATER ❑ SPRING L'J COMMUNrrY/PUBILC WATER SYSTEM Name of Community/Public Water System (if applicable): Buttermilk Metro District Engineering Firm: RFCC, Inc .fob Number: 20131001 Phone Number. 970-379-9847 Fax Number: Mailing Address: PO Box 4201 Cay, State, zip: Basalt, CO 81621 PLEASE READ BEFORE SIGNING: I certify that the above Information is complete and accurate and that I have provided complete and accurate information in all of the documents included in my application package. I acknowledge that EH/NR may revoke any permit I am Issued if my application is found to contain any Inaccurate, false, or misleading Information. I understand that no construction may be undertaken on an OWTS until an OWTS Construction Permit Is Issued. Owner Signature (Required): Date 7,11'1(13 Applicant Signature: Date: A _ it 1-31-13 led by EN/HR Staff: V Fee & Receipt # Date. - 01 Z 107-4.00o 336 3 (az�t3 I� in i! . .1� %ll,.. :Irl.i.in .. ��.+t R ••h' f . ie' Com' s tl jl � �..�. I.. �I I.... � I tCI�I/.), Pitkin County Environmental Health Department Contact Log Sfheet Naine: -M CA�o�''do Edd► 11 Parcel ID#: 2 6q. - 3` 13 - o l - q -W - Address: -16:55 l3 6 5' ©U -A G Q Date:,.....: _�ersort 9ke T_o Comments /Action to be- Taken _: ___._: --. _Initials Tme VO ,`�•S. �� o . n c. )S -9- r o Ici4 Loof_ 14 601,11,0 Ji'Dr-N fy-oxw,, L K +6 cLe W I.l n.50 c o unC'� o 0 0 CMIL ENGINEERINGA 'a LANs) SURVEYING NNEW An Employee -Owned Company November 11th, 2014 Project No. 2131035.00 Jim Gordon, Client Onsite Wastewater Treatment System (OWTS) Installation Observations 1365 Owl Creek Road Pitkin County, Colorado OWTS Construction Permit Number 0006.2013.POWT Jim, A High Country Engineering representative observed the installation of the onsite wastewater treatment system (OWTS) on June 23, 2014, July 9, 2014, and October 15, 2014 for the subject property. Excavation Services installed the system. The installation included a three -compartment Valley Precast concrete septic tank with a .5 MicroFAST® treatment system in the second compartment and Orenco® Biotube pump vault and Orenco PF3005 pump in the thin) compartment (specification enclosed). Effluent is dosed to four zones of a subsurface drip system, each with two 10' x 40' sections per zone and five laterals per 10' section, for a total of 3200 square feet. Valves are accessible from grade. Laterals were buried between 12 and 24 -inches below grade. An annual service contract for the MicroFAST® is required per manufacturer specifications and Pitkin County OWTS Regulation. A copy of this contract must be provided to Pitkin County prior to final approval of the OWTS Permit. Resting of one zone annually is recommended. Three zones (75%) of the subsurface drip system may be utilized, allowing one zone (25%) to rest. The resting zone must be rotated annually. The service provider must be responsible for executing, tracking, and documenting the rotation as part of the service contract for this system. The control panel for the system is located within the crawlspace of the home for maintenance purposes. The system was installed in conformance with the proposed design and functions per the design guidelines, HCE approves of the installation. Thank you, Matthew Langhorst, PE High Country Engineering, Inc. Installation Observation Photos Clean outs Inlet tee Biotube pump vault View of lids MicroFAST blower Trench for pump line • Valve box (one zone off for resting) Piping to zones Shallow installation of subsurface drip laterals Distance between laterals Coverage over subsurface drip field Re -vegetated surface Ft .5 MicroFAST Treatment System Item# with Discharge Pump in 3rd Compartment FAST.5-P (Up to s sedroonw) Top View ,24- PVC Riser Helgihit m Butyl Ftubber17w Sealant \ Pmbeble i I�i1�J��51�J� I 1■ p Section �® l View 6 I [Eiji Tank: *Meets ASTM C-1227 spec including C-1644-06 for resilient connectors 6000 psi concrete • Complete installation available in some areas Digging SPep Invert Dkrmm w 15' Long —x8' Wide '56" below inlet invert Inlet 56 Outlet 73 Length 162" Width 78" Height 92 - Net Cepedty NatVIOWt Inlet Side Middle Outlet Side Total Lid Tads TOW lot . a.... F. 604 gallons 917 gallons 505 gallons 2026 gallons 4,880 be 16,240 los 1211=11bs r4001Aaeoraru8 Water & (719) 395.6764 28005 Co. Rd 317 Wastewater P.O. Banc 925 • VALLEY; P Systems F= (719) 395-3727 Aft CO81211 roducts PIMAff iac. •service Website: www.valleypnec ast oom Email- tontdesk@val!ey�st-oom 70 LLI 0 \ \ �IL \ \ L I N \ \ O mw 4 ow oo — W w \ m W N w N\ z O W U� \J zx F- F L wam } CL g \ W p miz LU z C 0 0 � w' ~ H �za Mm 00 O M o tn~\UN K w H o\ ro LL a1�o \ W (n a o d LL J O N N N d Q p \ Q N \ V O E a U M n z' -Op O� v p a d W= a Q O Q o O W \ o N o O Q fn Z O 0 O ui U m 3 M-0 O Roaring Fork Civil Consultants, LLC PO Box 4201 Basalt, CO 81621 January 30, 2013 Project No. C 1022 Onsite Wastewater Treatment System Design Historic Homestead Victorian 2 -bedroom residence 1365 Owl Creek Road Pitkin County, Colorado Dear Client, Roaring Fork Civil Consultants, Inc. has designed an onsite wastewater treatment system (OWTS) that will serve the subject residence. The property is located outside of Aspen, in an area where OWTSs are necessary. SITE CONDITIONS A historic homestead Victorian currently exists and will be remodeled, requiring an upgrade to the existing OWTS. A future main house will be developed on the property and will be served by a separate OWTS. Water to the property is provided by a public water system. A minimum 25 -foot setback will be maintained from the absorption area to the water line(s). A ditch runs along the east side of the property and will be greater than 50 -feet from the absorption area. SUBSURFACE The subsurface was investigated by digging one 6 -foot profile pit. The profile hole consisted of sandy clay. No groundwater or bedrock was encountered. The profile hole was dug in a centralized location on the property. Prior to installation, an additional profile hole will be excavated adjacent to and down gradient from the proposed absorption for the historic homestead Victorian. CTL Thompson obtained a sample of the soil from the 6 -foot profile hole bnd ran a gradation analysis, as described in the report dated January 10, 2013, Project GS05720.001-300. The sample consisted of 0% gravel, 5% sand, 95% silt and clay- sized materials. A long term acceptance rate (LTAR) of9,30' gal/sq. ft will be used to design the OWTS. 0,70 Oe -,\r C -,r jo. pS.Ewz'q' DESIGN SPECIFICATIONS KWD The OWTS design for the historic homestead Victorian is based on 2 -bedrooms. An average daily wastewater flow of 300 GPD and design flow of 450 GPD will be used. The installation must include a 1000 -gallon, three -compartment Valley Precast top seam septic tank with a .5 MicroFAST® treatment system in the second compartment and a P-30 Orenco® pump in the third compartment. The field consists of four zones, with two 10' x 40' sections per zone, with 5 laterals per 10' section, for a total of 3200 SF. Laterals should be buried at a depth of no less than 12" and no more than 24". Distribution valves must be used to distribute effluent to the sections in the absorption area. Page 2 An annual service contract for the MicroFAST® is required per manufacturer specifications and Pitkin County OWTS Regulation. The subsurface drip system consists of eight sections. 75% of the subsurface drip system (six sections) may be utilized, allowing 25% of the system (two sections) to rest. The two sections that are turned off must be rotated annually. The service provider must be responsible for executing, tracking, and documenting the rotation as part of the service contract for this system. Construction must be according to Pitkin County Onsite Wastewater Treatment System Regulations, the OWTS Construction Permit provided by Pitkin County Environmental Health Department, and this design. OPERATION INFORMATION AND MAINTENANCE The property owner shall be responsible for the operation and maintenance of each OWTS servicing the property. The property owner is responsible for maintaining service contracts for manufactured units, alternating absorption systems, and any other components needing maintenance. The surface of the drain field should be seeded upon completion. Vegetation is an important factor in drain field performance. Erosion control should be practiced prior to and during re -vegetation. Geo - fabrics or plastics should not be used over the drain field. No heavy equipment, machinery, or materials should be placed on backfilled drain field. Livestock should not graze on the drain field. Plumbing fixtures should be checked to ensure that no additional water is being discharged to OWTS. For example, a running toilet or leaky faucet can discharge hundreds of gallons of water a day and harm a drain field. The homeowner should pump the septic tank every two years, or as needed gauged by measurement of solids in the tank. Garbage disposal use should be minimized, and non -biodegradable materials should not be placed into the OWTS. Grease should not be placed in household drains. Loading from a water softener should not be discharged into the OWTS. No hazardous wastes should be directed into the OWTS. Mechanical room drains should not discharge into the OWTS. The OWTS is engineered for domestic waste only. ADDITIONAL CONSTRUCTION NOTES If design includes a pump, air release valves and weep holes should be installed to allow pump lines to drain to minimize risk of freezing. Excavation equipment must not drive in excavation of drain field due to the potential to compact soil. Extensions should be placed on all septic tank components to allow access to them from existing grade. Precast concrete tanks and distribution boxes should be used, unless plastic or fiberglass is required. Access to all tank compartments and distribution devices is optimal. INSTALLATION OBSERVATIONS Roaring Fork Civil Consultants, Inc. must view the OWTS during construction. The OWTS observation should be performed before backfill, after placement of OWTS components. Septic tanks, distribution devices, pumps, dosing siphons, and other plumbing, as applicable, must also be Cr Page 3 observed. Roaring Fork Civil Consultants, Inc. should be notified 48 hours in advance to observe the installation. LIMITS: The design is based on information submitted. If soil conditions encountered are different from conditions described in report, Roaring Fork Civil Consultants, Inc. should be notified. All OWTS construction must be according to the county regulations. Requirements not specified in this report must follow applicable county regulations. The installer should have documented and demonstrated knowledge of the requirements and regulations of the county in which they are working. Please call with questions. Sincerely, Carla Ostberg, MPH, REHS P\pRADp G�......� lac R lq• �s o ;j C V OWTS DESIGN CALCULATIONS - for Pitkin USING LTAR Owner's Name HIMMEMEMEMEMEMParcel ID # RUNNEEM House Size (sq. ft.) II��������������y�� �l�i�N��ii�� (75 gpd or 100 gpd) 75 Number of Bedrooms in Main House Number of Offices, Libraries, Studies, Similar-sized Rooms in Main House Number of Bedrooms in Detached Caretaker unit Number of Offices, Studies, Similar-sized Rooms in Caretaker Unit (If the caretaker unit is ATTACHED, treat as if part of main house.) Average Daily Waste Flow 300 State Review Required? no LTAR (1) Design Flow (Q) = # potential bedrooms X 2 people/bedroom X gpd X 1.5 Q= 450 Minimum tank capacity 562.5 gallons Absorption Area (=B20 X 1.0/1317) A = Q x 1.0 loading/LTAR A = 1,500 sq. ft. of absorption area required Abserp ion Area (—Q/5 X SQRT- pere rate) ;N4TI4 SECONDARY TRE ATMENT (no leading A= 1,500 sq. ft. of absorption area required faeterl Abs. Area w/ loading factor (1325) Trench Bed Quick4 Trench Quick4 Bed Pipe and Gravel 1350 1500 137 152 Dosing 1200 1200 122 122 Chambers 1050 1350 106 137 Max Allowable 750 1050 76 106 Secondary Treatment Abs Area w/ out loading factor (B28) Trench Bed Pipe and Gravel 1350 1500 137 152 Dosing 1200 1200 122 122 Chambers 1050 1350 106 137 Max Allowable 750 1050 76 106 100 SETBACK FROM WELL # of feet = 50 SETBACK FROM POND, STREAM OR IRRIGATION DITCH # of feet = 25 SETBACK FROM DRY GULCH # of feet = J N 0' 50' 100' Scale: 1" = 100'-0" ON Roaring Fork Civil Consultants, LLC PO Box 4201 Basalt, CO 81621 SITE PLAN _ ,�_o Gordon Residence 1365 Owl Creek Road Aspen, Colorado 81611 Project Number: C1022 05qp?D '/ R Cgyc �`SF O :Q yoi 39793l"� -ONAL ENG\ Date: 01/30/13 Designed By: CO Drawn By: ANG W1.0 Sheet 1 of 4 N 0' 10' 20' Scale: 1" = 20'-0" WI7 CLEANOUT` " SDR -35 PUMP LINE TO DISTRIBUTION BOX 3d PROFILE H(:*E / / / r / plff I /JEW3200 SF DRIP IR RIG ION SYSTEM 2 M N. 3 NDO L/C / J R r 1PROPMOS ED _OW Z—r. Roaring Fork Civil Consultants, LLC Gordon Residence Date: 01/30/13 PO Box 4201 1365 Owl Creek Road Basalt, CO 81621 Aspen, Colorado 81611 �/ Y `n' 2 • Designed By: CO Project Number: C1022 Drawn By: ANG Sheet 2 of 4 TYPICAL PLAN VIEW INLET LINE DISTRIBUTION VALVES FROM PUMP PLACED IN PLASTIC OR CONCRETE CHAMBER BOX FOR ACCESS. INSTALLED II /LEVEL FOR EVEN DISTRIBUTION. PERFORATED LATERALS MINIMUM 2' BETWEEN SECTIONS PERFORATED LATERALS HEADER LINES TO ADDITIONAL SECTIONS. GRAVITY AT 1/8 -INCH PER FOOT DROP MINIMUM DISTRIBUTION VALVES 2" PUS LEVEL SOLID TO ADDITIONAL SECTIONS IF APPLICABLE 2" BALL VALVES c -11— 1 v — i ivivr TYPICAL CROSS SECTION 2" PVC VENT PIPE 24" OAX 'BETWEEN LATERALS 2" PVC LATERALS WITH 1/4 -INCH HOLES ON 8 -INCH LEVEL CENTERS, WITH HOLES FACING MANIFOLD. SOLID PIPE. DOWNWARD. LATERALS MUST BE LEVEL. Roaring Fork Civil Consultants, LLC PO Box 4201 Basalt, CO 81621 TO — ADDITIONAL SECTIONS IF APPLICABLE 3 SECTION DETAILS NOT TO SCALE Gordon Residence 1365 Owl Creek Road Aspen, Colorado 81611 Project Number: C1022 2" PVC OBSERVATION PIPE WITH CAP ON EACH SECTION 6" - 8" TRENCH WIDTH 0' SECTI O ��Ai�G•i/C 39793 IONZ ENG Date: 01/30/13 Designed By: CO Drawn Bv: ANG 12" MIN W3.0 Sheet 3 of 4 HISTORIC HOMESTEAD VICTORIAN - DESIGN 2 -BEDROOM RESIDENCE (75 GAL/PERSON/DAY x 2 PERSONS/BEDROOM x 2 BEDROOMS) AVERAGE DAILY FLOW = 300 GALLONS DESIGN FLOW = Q = 1.5 x 300 = 450 GALLONS TANK: 450 x 1.25 = 560 GALLONS CAPACITY REQUIRED USE 1000 -GALLON 'FAST', THREE -COMPARTMENT TANK WITH PUMP USE 0.5 'MicroFAST' ABSORPTION AREA: LTAR =.02 GAL/SF Q/LTAR = 1800 SF WITH 20% REDUCTION FOR DOSING USING SURFACE DRIP AREA FOR 2 -BEDROOMS WITH LTAR 0.20 = 3158 SF 4 ZONES = 800 SF PER SECTION 4 SECTIONS OF 10' x 40' PER ZONE _ (5 LATERALS EACH 10' SECTION) .5 MicroF 4 CLEANOUT DETAIL NOT TO SCALE reatment System item# with Discharge Pump in 3rd Compartment FASTS -P Tank: *Meets ASTM C-1227 spec including C-1644-06 for resilient connectors • 4000 psi concrete • Complete installation available in some areas (Up to 3 Bedrooms) IVL �0" Clear Access Top View .5 MicroFAST 7 Unit " Coupling for Pumping Access Butyl Section View a ............ M'IaoFAST 0.50 FAST URT Minimum -leight Digging Specs SLIP-ON PVC CAP Dimensions 15' Long x 8' Wide 56" below inlet invert DO NOT GLUE Outlet 1 73" 1 FINISHED Width 1 78" Height 1 92" GRADE EFFLUENT LINE - 4" SCHEDULE 40 OR 4" SDR SEWER LINE - 35 P.V.C. 4" SCHEDULE 40 P.V.C. INSULATED COPPER TRACER f WIREMAY BE INSTALLEDTO OELINE IN FUTURE 4 CLEANOUT DETAIL NOT TO SCALE reatment System item# with Discharge Pump in 3rd Compartment FASTS -P Tank: *Meets ASTM C-1227 spec including C-1644-06 for resilient connectors • 4000 psi concrete • Complete installation available in some areas (Up to 3 Bedrooms) IVL �0" Clear Access Top View .5 MicroFAST 7 Unit " Coupling for Pumping Access Butyl Section View a ............ M'IaoFAST 0.50 FAST URT Minimum -leight Digging Specs Invert Dimensions 15' Long x 8' Wide 56" below inlet invert Inlet 56" Outlet 1 73" 1 Length 162" Width 1 78" Height 1 92" Net Capacity Net Weight Inlet Side 604 gallons MiddleOutlet 917 gallons Side 505 gallons Total 2,026 gallons Lid 4,880 lbs Tank 16,240 lbs Total 21,320 Ibs Water & (719) 395-6764 28005 Co. Rd. 317 Wastewater P.O. Box 925 •Systems Buena Vista, CO 81211 1�� VALLEY • ProductsFax: (719) 395-3727 PRECAST, Inc. •service Website: www.valleyprecast.com Email: frontdesk@valleyprecast.com 5 TANK DETAIL 3 -COMPARTMENT NOT TO SCALE Roaring Fork Civil Consultants, LLC Gordon Residence PO Box 4201 Date: 01/30/13 Basalt, CO 81621 1365 Owl Creek Road \ /� / /I .0 Aspen, Colorado 81611 �/ V Designed Bv: CO 4