pitkin.eh.264303202002 (2016) (1994 System)
iTKIN LOA Oft U NT Pitkin County Environmental "ealth Department Onsite Wastewater Treatment System (OWTS) USE PERMIT Permit for Continued Use of an Existing OWTS 76 Service Center Road, Aspen, CO 81611 Phone: 970-920-5070 Fax: 970-920-5077 www.aspenpitkin.com/EHNR Parcel ID #: 2645-032-02-002 OWTS Use Permit #: 0009.2016.POWU Date Issued: 5/5/2016 Concrete 2 compartment tank* Issued By: Bryan Daugherty Expiration Date: 5/5/2017 Owner(s): Jack Wilkie Property Address: 7035 E Sopris Creek Rd (2) Legal Description: Lot 2, Capitol and Elk Creek Licensed Inspector: Carla Ostberg Inspection Date(s): 6/30/15 SYSTEM INFORMATION Components Type Capacity/Size Primary Treatment Unit Concrete 2 compartment tank* 1000 gallons Secondary Treatment Unit Absorption Area Gravelless chamber trenches 242 ft2 Other System Components Pump chamber 5' diam. X 8' ®In use at the time of the inspection. ❑Not in use at the time of the inspection.* *If the OWTS was not in use at the time of the inspection, it is recommended that the system be re-evaluated when it is in use for a more accurate evaluation of the system. System Records: Permit #: 94038 Date of Issuance: 2/3/94 Date of Final Approval: 10/14/94 # of Bedrooms or fixtures served by OWTS: The system is designed to serve 3 bedrooms, the system serves a 2 bedrooms in the main house. Operational Status: According to the inspector's observations, the system was functioning as designed at the time of inspection. Tank lids were replaced because they had deteriorated. Pump chamber had some infiltration at the inlet pipe. Pump and alarm v✓ere tested and worked properly during inspection. There were no signs of failure in the soil treatment area. Inspector Recommendations: Electrical outlet supplying power to the pump should be made water tight, install an effluent filter to the outlet of the tank, seal inlet pipe to the pump chamber to prevent infiltration of water. Department Recommendations: N/A Issuance of this OWTS Use Permit is based solely on the conditions observed and reported by the inspector to the Department on the date of the inspection(s) and on Department records at the time of permitting. The issuance of this permit does not constitute a guarantee, warranty, or representation by the Department that the system will operate properly or will not fail or that the system will not be subject to future enforcement action to correct non-compliant conditions. Estimated capacity of the system has been listed on the permit and we recommend that you monitor and/or meter water use to prevent overuse and possible failure. Pitkin County Environmental Health Department Onsite Wastewater Treatment System (OWTS) tit ' I't USE PERMIT APPUCATION 76 Service Center Rd - Aspen, CO 81611 Website: www.aspenpit1dn-axNettnr1 Annlic-afinn fns it . s -- _ o%am ..� Parcel IDS (avatiabb from fire Pwm Caarty Asseeaor"a OfRce 970-92" 160 Or at r-. . t1ri1t:a5S85SO O"oI:(^ e Q �i ` Cl j J U O C) Purpose of Use Permit- EHG EIM TRANSACTION ❑ RatODB./ADDn. Property Address: , M)dc F n Subdnrisiorr t Residences: Odw # of Bedrooms: 16dune4/tises �y i 1 ► t S IIWPM ty kimR" s) must be pvovioled for the owner signing &* PLEASE READ BEFORE SIGNING: 1 corwy that the above indanrr_Mn n Is 1 P-06 and acetra4e and that 1 have provided oorrrpteb gaud acpoab kdwontion in aft of the dorm �°W ob Pwu* I aw bound N My appYntlon Is iorwd bo conWn ary Please allow 3-5 busmss days for pA7CaS&M of Use Aermiis. FOR OFFICE USE ONLY Received by EH staff: Fee & Receipt #: Date: CBO Inc. r 33 Four Wheel Drive Road Carbondale, CO 81623 r cell) 970-309-5259 office) 970-704-0484 carla.ostberg((cDgmail.com July 6, 2015 Jack Wilke iw@iwbinc.com Onsite Wastewater Treatment System (OWTS) Use Permit Inspection 7035 E. Sopris Creek Road (1994 OWTS) Pitkin County, Colorado Mr. Wilke, As requested, CBO Inc. performed an Onsite Wastewater Treatment System (OWTS) Use Permit inspection at 7035 E. Sopris Creek Road, Snowmass, Colorado on June 30, 2015. The legal description of the property is Lot 2, Capitol and Elk Creek Subdivision. There are two residences on the property. The subject OWTS serves two bedrooms in the main residence. The permit and record drawing was provided by Pitkin County Environmental Health Department (Parcel ID #2645-032-02-002). The subject OWTS consists of one 1000 -gallon, two-compartment concrete septic tank followed by a concrete pump chamber (5 -feet in diameter, 8 -feet deep) with a pump. Effluent is dosed through a 2 -inch diameter pipe to a manifold and then to two gravelless chamber trenches, each consisting of four'Standard' Infiltrator® chambers. The septic tanks are located on the southwestern corner of the main house. Both manhole lids of the 1000 -gallon septic tank were accessible from grade. Both lids of the 1000 -gallon septic tank were in disrepair and were replaced by D&D Septic Services. Both the inlet and outlet tees were present. The outlet tee is angled badly at a downward angle. This could be an indication of settling. We typically recommend the installation of an effluent filter. The outlet tee would need to be adjusted and extended for the installation of a filter. If a filter were to be installed, this filter would need to be cleaned annually, or as needed. A cast iron lid covers access to the pump chamber. Accumulation of sludge measured approximately 12 - inches in the purnp chamber at the time of the inspection. Both the 1000 -gallon tank and the pump chamber were pumped by B&R Septic during the inspection. The concrete surrounding the inlet pipe appears to be deteriorating. A trickle of water was observed around the pipe during the inspection. We recommend efforts to minimize infiltration into the pump chamber by sealing the area between the concrete and pipe. Electrical connections for the pumps are made through a traditional electrical outlet. This outlet is not water -tight and is not recommended. If this pump were to be replaced in the future, we recommend it be replaced with an Orenco® pumping system, which would include a water -tight electrical splice box and control box allowing manual control of the pump and a visible and audible alarm. During the inspection, the pump was tested and was found to be functional. The alarm in the garage sounded when the high water float was lifted. The approximate STA had a covering of tall, native grasses. We walked the area and no inspection ports were observed. The area appeared to be dry with no signs of surface saturation or failure at the time of the inspection. This evaluation is not a guarantee of future system performance. This inspection is good for one year. Recommendations: • Install effluent filter on outlet tee of 1000 -gallon septic tank (will require extension and re- alignment of pipe). If installed, this filter will need to be cleaned annually, or as needed. • Seal around inlet pipe of pump chamber to eliminate the chance of infiltration into the pump chamber. • If pump is replaced in the future, replace with Orenco® pumping system with water -tight splice box for electrical connections. This report should be submitted to the Pitkin County Environmental Health Department. The following links are the required application and application checklist. Application: http://www.pitkin,-ounty.com/DocumentCenter/HomeNiew/621 Application Checklist: http://www.pitkin,-ounty.com/DocumentCenter/HomeNiew/620 Disclaimer: This inspection is intended only as an evaluation of the present condition of the OWTS based upon what was observed and the Licensed Inspector's expertise in onsite wastewater technology. The inspector has not been retained to warrant or guarantee the property functioning of the system for any period of time in the future. Because of numerous factors which may affect the operation of an OWTS, as well as the inability of the Inspector to supervise or monitor the use or maintenance of this OWTS, this report shall not be construed as a warranty by the Inspector that the system will function properly for any particular prospective buyer, and the Inspector disclaims any warranty, either expressed or implied, arising from the inspection of the OWTS or this report. The evaluation does not ascertain the impact the system is having on groundwater. Please call with questions. Sincerely, Owt �-t 6&-� &As Carla Ostberg, MPH, REHS NAWT Certified 'Inspector Certification # 110441TC Exp. 2016 June 30, 2015 Clean out located in raised bed box, just under bark low 77%" 1,� F k Looking northeast Inlet tee replaced Outlet tee (angled) Pump chamber covered with cast iron lid Pump chamber Inlet pipe into pump chamber Note staining over and under inlet pipe. Concrete around knock out is deteriorated. Trickle of water during inspection was evident, even though no water was entering chamber through the pipe. Area around knock out may not be completely water tight. • ,.�.. l *-, A ,.S-�' 9�': •fr'r�--4-�. s'��i2x�'�iLz i;+C��r �.--:"s-;�-'1,1 iTKIi\i COUNT IV No g Onsite Wastewater Treatment Systems ( Permit Inspection Form Pitkin County Environmental Health Department 76 Service Center Rd, Aspen, CO 81611 Phone: 970-920-5070 Fax: 970-920-5374 Website: www_ .aspenpitkin.c form for continued use of an existing OWTS Use Owner's Name: ( 50Y. �� 2 Address: Parcel Number: D49 q ED1 _ D ?) 2- ,5 Inspection Date: {� _� I5 4 i tt Inspector's Name: �' 1T E� j -, Business Name:C Phone Number 01 Email: " i T _ _2511-6t v` Pitkin County Systems Inspector License Numbers.....' "� e A copy of this inspection report will be remitted to Pitkin County Environmental Health Department by the licensed Systems lnspector within 60 days of the inspection reaardless of whether the system Posses or fails. QUESTIONS FOR PROPERTY OWNER PRIOR TO INSPECTION: Is the home currently occupied? (YES° NO If NO, how long has the home been vacant? , / — bJ A V\A- How many bedrooms are in the home? 33 t¢ - If secondary treatment is used, who is the f r maintenance provider? NJ A ( H} ic( RECORDS: u I� Were system records available from Pitkin County?YE5 NO If YES: Permit number: i Date of Final Approval: __Ll I _q1 1 # of bedrooms permitted: Was an as -built drawing available? AYES NO Is the as -built drawing accurate? YES NO If NO: Complete a drawing of the system on last page of this form as accurately as possible. Any question marked FAIL will require correction before an OWTS Use permit is issued. SITE CONDITIONS: Proper grading, no evidence of erosion? Improper vegetative cover? Evidence of compaction such as heavy machinery or livestock? Improper discharges such as straight pipes? Evidence of high ground water? Snow cover present? Page 1 PASS FAIL YES YES P FAIL YES NO YES Page 2 y TANK: Tank 1 Tank 2 Tank 3 Tank capacity gallons `7r r, - gallons Tank material gallons # of compartments Date of last pumping Lids/risers in good condition PASS FAIL PAS FAILPASS Risers to grade _YES> NO YES NO YES FAIL Oil Av Riser height NO `� Riser condition/watertightness Inlet sanitary T/baffle P FAIL PASS ----.�,,.•• L _ - SASS Outlet FAIL sanitary T/baffle P'�� FAIL Ppm _._L PASS Effluent filter (if part of design) PASS FAIL' 3 FAIL PASS Condition of tank material PASS F LA PASS, FAIL FAIL A FAILA Tank was pumped for inspection YES NO FAIL YES NO YES If YES, list the pumping company t - NO 1` If NO, when was the last pumping Scum level (1st c)mpartment) inches inc esr a Sludge level (1st compartment) inches inches inches Scum level (2nd compartment) inches inches inches Sludge level (2nd compartment) inches inches inches Backflow (if pumped) PASS FAIL PASS FAIL PASS inches Midtank baffle PASS FAIL N/A PASS FAIL N/A PASS FAIL FAIL N/A Watertightness PASS' FAIL PASS FAIL PASS FAtL } PUMPS/DOSING 51PHON5: Is a pump or dosing siphon present? YES If YES, is NO the pump/dosing siphon functioning__YE_S--� properly? ? p Y 3 Does thePump/wiring/dosingsi hon a P� p appear to be in good condition? Is the high water alarm ` FAIL FAIL Q I# G, working, both visible and audible?--' SECONDARY TREATMENT: FAIL Is v . r a secondary treatment unit present? � YESf UNKNOWN." If YES, does the unit appear to be in good working condition? YES NO Does the owner have a current maintenance contract for the unit? YES NO UNKNOWN iii 0_ Maintenance Provider: Phone: If there is no maintenance contract, a contract must be in place prior to occupancy of the home. A copy of the contract must be submitted to Pitkin County Environmental Health Department. ABSORBTION AREA: Effluent surfacing? r'PAit' FAIL Evidence of past surfacing? - YES Surface dampness? NO YES Excessive odors? TNO_:. YES Field location verified by observation ports or probing: Ports Probing trim"— Liquid in observation port? NO YES ,A 1j , 1 If YES, record depth: inc Distribution Box or ADV part of original design? YES LNC UNKNOWN If YES, ptilp�+n� is it accessible from grade? YES NO Is it level and in good condition? PASS FAIL Page 2 Any problems with the system that were not addressed in the inspection checklist? Please list any recommendations for the continued use of the system: Were any repairs done as a result of this inspection? NO ; YE ti If YES, please describe the repairs. To the best of my knowledge and training, the information collected in this inspection is accurate as of 20 licensed Systems Inspector Signature: a'Lei} Additional Notes: U. VJ wiz -7 r-6/ Pr. .D #.2(o1QS 0•3Z 02 -'00Z ASPEN/PITi IN ENVIRONMENTAL HEALTH DEPARTMENT APPLICATION FOR A,Np INDMDUAL SEWAGE DISPOSAL SYSTEM OSDS) PERMIT Name of OWNER _jACAG � vyK-vr_- Bus. Phone # 17_? -42�1� Mailing Address_ "fid 5 0 _ea-�s eA ,G� �i!c[ Home Phone # `j77-4220 Name of AGENT Bus. Phone # Mailing Address ( ) Copy of Permit to be Sent to: Home Phone # PERMIT IS FOR: () NEW INSTALLATION, () REPAIR,XALTERATION NOT DUE TO FAILURE, or () EMERGENCY USE, for permit # STREET ADDRESS of Property: 9035 #4gq his C'eg_P.A 52 =Dc�ss Gots LEGAL DESCRIPTION of Property: lot ,, block _, filing _, and subdiv. Size of Lot L_ acres Type of Structure Proposed SINC,LE Fy4M% _`t' ��st1G�Df Ttort, •- U1V_A_k+€:va- # BEDROOMS 3, # LOFTS O , # GARBAGE DISPOSALS I , # DISHWASHERS J_, # CLOTHES WASHERS I. "Q Water Supply:/KPrivate Well, () Spring, () Stream, or () System (Public or Private Name: ) IS PROOF OF ADEQUATE WATER ATTACHED? () YES orXNO HAS THIS PROJECT BEEN APPROVED BY PITKIN COUNTY? RYES or () NO :ppiication for an Individual sewage disposal system permit Is hereby submitted. The undersigned acknowledges that the above information Is true and that false Information will invalidate the application enc any subsequent permit issuance of the permit coos not explicitly or Implicitly Imply the approval of any other permit required for construction pursuant to Pitkin County codes. No construction may be undertaker, :ntil all approvals and permits have been obtained, The owner assumes all responsibilities In case of failure or Inadequacy of this system. SIGNATURE OF APPLICANT _ ,1�Gf�---" Date Z 9L The application becomes invalid 12D days from the date signed. This Permit is valid only for the design as specified below. wrrrwwrewwrwrwwwwrrw"wr""'wBELOW FOR OFFICE USE ONLY"'wwaewwwrw:ww*rwwwwa*rwrwwww INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT # q�IO E5 5150 fee paid ( ) Yes. Date received :z f 21 ,� Receipt # % 7 4 Received By K 5� h'` DESIGN CRITERIA OF SYSTEM TO BE INSTALLED: Any changes must be submitted and approved in writing. f-B�/ft;olation Rate: mpl, Average Daily Waste Flow: gallons. Is an Engineer Designed system needed? () Yes or 1 No (AII plans and specifications of the engineer shall be followed. Any changes must be approved in writing and the engineer ;hall certify the final installation to the Environmental Health Department In writing.) Minimum Septic Tank Capacity _IL: Lh 0 gallons Absorption Area 4 square feet minimum O Absorption Bed, �k Absorption Field in Trenches, O Gravel -loss system, O Pumping/Dosing Chamber, ( ) Absorption Pit . v `%, .��.��Lt��il�...e_� f>r'Z1 �✓ � f .-�ir.c �j a� �- d.�e��' r,� >�t�-,-e1 _/. L ;f r GFf "� d►ti rt4%3M r= ssti. �A t�w-t �/ Ccw4 eL �3 r,ii►.,tom. Stages requiring inspection: O Befere excavation, O Upon completion_ aqd prior to placement of gravel, O Befor6'covering dis4hlon system of absorption 'ieid, ( ) Prior to backfill of any com,00nent and any situation deemed necessary by Environmental Health Department Staff. 'tans and specifications of the proposed Individual sewage disposal system have been reviewed and are considered satisfactory. Permission Is hereby granted to the owner or his agent to perform the work idicated above in accordance with the Pitkin County Individual Sewage Disposal Regulations In effect on the date of Issue. In addition to general provisions set forth in any attachments, this Permit Is subject the following additional terms and conditions if any: 4PPROVED FOR ISSUE BY: ,. , DATE OF ISSUE: 2 -GAG _ y y '�e above individual sewage disposal system hes been inspected 1 r se by the Aspe itkin Envifq ental Health Department The owner assumes all responsibilities In case failure or inadequacy of lh-s vstem. Complete as -built drawing and all specifications of as -butt a included with this permit h FINAL INSPECTION BY: �1 {� DATE OF FINAL INSPECTION: /U aOTH:UDO:JTCPC:WP:PERMiT 130 SOUTH GALENA STREET • ASPEN, COLORADO 61011 • PHONE 301.920.5070 FAX 3133.920.5197 a/PEHO 1/84 PRINTED ON RECYCLED PAPER ASPEN,, EARTHMOVING WTI. eliF Isos /a •/y gv �rs ,g T a K �oc•�o C�!`�_ t��yilT Box 325 Old Snowmass, Colorado 81654 303 927 4744 Fax 927 8012 D&D Septic Services PO Box 3681 Eagle, CO 81631 (970)328-0174 DDSepticServicestgmail. com INVOICE Date: July 4, 2015 To: Jack Wilke 7035 E Sopris Creek Snowmass, CO Job Address Job Description Payment 7035 E. Sopris Creek Repair Due upon receipt Qty Description Unit Price Line Total 3 Lids i Delivery, Installation, and Disposal of old lids Make all checks payable to D&D Septic Services or call the office at (970)328-0174 to pay by credit card. Thank you! tE. Residential Biotube' Effluent Filters Applications Our patented* 4 -in. (I00 -mm) Biotube Effluent Filters, Biotube Jr., Biotube Insert Filters, and Biotube Base Inlet Filters are ideal for residential septic tanks and have a lifetime warranty. They prevent large solids from leaving the tank, dramatically improving wastewater quality and extending the life of residential drainfields. 4 -in. (100 -mm) Biotube Effluent Filter 4 -in. (100 -mm) Biotube Jr. (4 -in. Biotube cartridge avail- able separately as Insert Filter) 8 -in. (200 -mm) Base Inlet Filter 4 -in. (100 -mm) Insert Filter Orenco' superior effluent filters resist clogging better than all other brands. Our stan- dard, full-sized 4 -in. (100 -mm) Biotube Effluent Filter provides maximum long-term protection in a complete package, with housing. Our 4 -in. (100 -mm) Biotubejr, at half the size of our standard model, has more filtering capacity than the full-sized filters sold by other manufacturers. For tanks with existing outlet tees, the Biotube Insert Filter is ideal. And for low profile tanks, there's the Base Inlet Filter. * Covered by parent numbers 5,492,635 and 4,439,323 To Order Call your nearest Orenco Systems®, Inc. distributor. For nearest distribu- tor, call Orenco at 800-348-9843 or go to www.orenco.com and click on "Distributor Locator." APSTN Rev. 3.4 ©11/10 Orenco Systems®, Inc. Standard Features & Benefits • Has 5-10 times more flow area than other brands, so lasts many times longer between clean- ings, increasing homeowner satisfaction • Installs in min- utes inside new or existing tanks; extendible tee handle for easy removal Optional Features & Benefits • Alarm available, to signal the need for cleaning • Flow modulating discharge orifices available to limit flow rate leaving tank, mitigat- ing surges and increasing retention time • Custom and commercial sizes available • Easy to clean by simply hosing off whenever the tank needs pumping • Removes about two-thirds of sus- pended solids, on average, extending drainfield life • Corrosion -proof construction, to ensure long life • Lifetime warranty Biotube Filtering Process Effluent from the relatively clear zone of the septic tank, between the scum and sludge layers, horizontally enters the Biotube Effluent Filter. Effluent then enters the annular space between the housing and the Biotubes, utilizing the Biotubes' entire surface for filtering. Particles larger than the Biotube's mesh are prevented from leaving the tank. Orenco Systems Incorporated Changing the Way the World Does Wastewater' www.orenco.com Nomenclatures 4 -in. Biotube Filter (standard) FT011040❑-11FIC-1 I—Option,: Blank = no options M = flow modulation plate installed A = float bracket attached Cartridge height: 28" and 36" are standard Housing height: 36" and 44" are standard Filter diameter (inches) W =fits Type 3034 outlet pipe S = fits Schedule 40 outlet pipe Blank = 1/8" filtration P = 1/16" filtration Biotube effluent fitter series 8-1n. Blotube Filter (base inlet model) FT F1 08 22 -14 BC] I Options: A = float bracket FS = 2" outlet orifice FSO = 2" outlet orifice and overflow plate' Base inlet model Cartridge height: 14" standard Housing height: 22" standard Filter diameter (inches) 08 = 8" Blank = 1 /8" filtration P = 1/16" filtration Biotube effluent filter series Also available with coupling and sleeve as a "kit': FT-OVERFLOWKIT 4-1n. Blotube Jr. (includes cartridge and housing) FT J F1 F1 04 18 =1 I Options: Blank = no options M = flow modulation plate installed A = float bracket attached Cartridge height (inches) Filter diameter (inches) W = fits Type 3034 outlet tee S = fits Schedule 40 outlet tee Blank = 1 /8" filtration P = 1/16" filtration Junior series Biotube effluent filter series 4-1n. Biotube Filter Insert (cartridge only) FT W o4 18 -FI-71 —TFor customized options (e.g., NC indicates North Carolina regions) W = fits Type 3034 outlet tee S = fits Schedule 40 outlet tee Cartridge height (inches) Filter diameter (inches) Blank = 1 /8" filtration P = 1/16" filtration I Insert Biotube effluent filter series 4 -in. Biotube Effluent Filter 0 Extendible Stainless Ste g Top se Air v 3e° fil Solid Filter t Distributed By: 4 -in. Biotube Jr. 0 , c , _, ",ago 0 7035 E Sopris Creek Rd )Sic earth Do Your Part Be SepticSmart: The W4 and DoKts of Your Septic System Learn these simple steps to protect your home, health, environment and property value: sepbamart U.S. Er--eMA Rotation Agency M Do: • Have your system inspected (in general) every three years by a licensed contractor and have the tank pumped, when necessary, generally every three to five years. Don't: • Pour cooking grease or oil down the sink or toilet. • Rinse coffee grounds into the sink. • Pour household chemicals down the sink or flush them. Don't: • Flush non -degradable products or chemicals, such as feminine hygiene products, condoms, dental floss, diapers, cigarette butts, cat litter, paper towels, pharmaceuticals. Don't: • Park or drive on your dra infield. The weight can damage the drain lines. • Plant trees or shrubs too close to your drainfield, roots can grow into your system and clog it. Don't • Concentrate your water use by using your dishwasher, shower, washing machine, and toilet at the same time. All that extra water can really strain your septic system. Do: • Eliminate or limit the use of a garbage disposal. • Properly dispose of coffee grounds & food. • Put grease in a container to harden before discarding in the trash. Do: • Dispose of these items in the trash can! Do: • Consult a septic service professional to advise you of the proper distance for planting trees and shrubs, depending on your septic tank location. Do: • Stagger the use of water -generating appliances. This can be helpful especially if your system has not been pumped in a long time. • Become more water efficien by fixing plumbing leaks and consider installing bathroom and kitchen faucet aerators and water -efficient products. x�# LIGEND AND NOT{• `\` '\ �� O auNa IFIaJ•el N aaaCJlMe RAs �r• ` • • ateaeY oL.NK \ T SO Pit.ua .JJI.Irwu RO AD e1NcUvi &.R`:iiPi », wla 8 i 772 ` 0 4. MJ. JJ, AMENDED LOT 1 0 • 1W4 ra�i.all7J 6 V AMENDED LOT 2 bfsia CERTIFICATION. a nY. rJalm efwl yIu`'^_�� a Ma na le a� ' Mlae•� i. �ti T ISIl ROVEYENT SURYET ate; WON=. asy =. MEIMEO eY ASPEN SURVET ENGINEERS, INC. 210 —O O ,:," I AaMll, cotawo lel. NIpIIE/fM ro2ol na-aels eeF.earexelwvErD•. wlfM.tan SIS 12�tIK J E Iofell `rte �Z�N 5&Prtc,' maw-p,e,1w* -�1