HomeMy WebLinkAboutpitkin.eh.264503301012 (2005)Pitk' ':ounty Environmental Health Departr nt
Per....c for an Individual Sewage Disposal S, - cem
0405 Castle Creek Road, Suite 10, Aspen, Colorado 81611
Phone 970-920-5070 / FAX 970-920-5077
Permit # 05045 Parcel ID # 2645-033-01-012
Type of permit New( ) Repair( ) Addition/Remodel to House( x )
Name of Owner Peter and Frieda Wallison
Street Address 1880 Lazy O Road
Property legal description Lot 1
Size of lot 3.7 acres
Water source Lazy O Water system
# of bedrooms in house
Caretaker unit attached
# of bedrooms in caretaker unit
Designed for what # rooms (list)
O Subdivision
Total square footage of the house Greater than 6000 sq ft
# of offices, lofts & similar sized rooms in house
Total square footage of the caretaker unit
# of offices, lofts & similar sized rooms in caretaker unit
2 new bedrooms (existing system sized for 6 bedrooms {4 + 1 bunkroom})
Permit information
Designed by Schmuesser Gordon Meyer, Dan Cokley
Mailing Address 118W 6th Street Glenwood Springs CO
Perc rate 54 Profile hole depth 9 ft Depth to groundwater or bedrock
Minimum Septic tank capacity 1137 gallons Minimum Absorption area
Comments
3 ft to bedrock
986 sq ft w/ 30% reduction
Septic permit approved per compliance with the engineer design and specifications dated August 5, 2005. Any
changes must be approved by this department and the design engineer prior to them being made.
Minimum horizontal distances between components of the system and physical features shall conform to the Pitkin
County ISDS regulations. The field must be at least 10 feet from the property line. The ditch must be lined within
50 feet of the field.
This system will consist of one 1250 gallon two compartment tank with an effluent filter on the outlet. A dosing
siphon per engineer specification will be used to distributed effluent to the field. A demonstration of equal
distribution by the dosing siphon should be demonstrated at the time of the inspection. The field will consist
of a minimum of 2 feet of sand. The sand must conform to the intent of Section 6.28.670 A. of the Pitkin
County ISDS regulations or conform to ISDS Policy 2005-001. An invoice to document the type of sand
material must be submitted. 108 Quick 4 gravelless chamber units will be used on top of the sand mound in a
bed configuration, 6 units by 18 units.
This department does riot endorse any brand of products. This permit must be kept on-site during installation.
The engineer must do a final inspection of the installation and submit an as -built letter to this department. This
department must also be called for an inspection with a minimum of 48 hours advanced notice.
*Revegetation over the area of the field is very important for the functioning of the system. Pitkin County has guidelines that must be
followed to assure the plants that are introduced are appropriate for the conditions of the area. The use of native plants is strongly
encou
Permit approved by: t„ad*kc L Date: g I S I Dt)
Plans and specifications of the proposed individual sewage disposal system have been reviewed and are considered
satisfactory. Permission is hereby granted to the owner or the agent to perform the work indicated in accordance with the Pitkin
County ISDS Regulation in effect at the time of issue. This permit becomes invalid 6 months from the date that the permit was
issued unless system construction has commenced or an extension has been approved in writing by the Department.
As -built drawings, must b,oncluded with this per it before the final approval will be issued.
Installer:—1('Q'Un lrl > O� � �Zwb 1 Lt -G
Final approval: ` d- A Date: ( l
A, 1. C I I :. o 14 r +r In nvi .,-. ii, CC)..
03 08508• f'iticin uo tnv. MealLr7 to iu, 'JC -U- .%j
t
'f PITKIN COUNTY ENVIRONMENTAL HEALTH DEPARTMENT
APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM
0405 Castle Creek Road, Suite 10, Aspen Colorado 81611
,�► Phone (970) 920-5070 Fax (970) 920-5077
1
Name of OWNER P�T�Q. f:<0 --PA W4L.L-.L5,,s>J _
Owners Mailing Address $ L-4221 a 1Z a 6-12
City, State, Zip Zf r7 J MA uS , g (6S Y Business Phone:
Home Phone: q2-7 ZY O I E-mail Address:
Primary Contact Person (all communication regarding this permit will go through this person)
Name D A ( P PQ� v -G E L -1 -
Co n M Q eiL w ki 0 &3 Cq(N LIQ.
Contact Mailing Address p. a, (3a 6 3 r
City, State, Zip c -A -R dSrl 0A, LA �'L 3 Business Phone : C( -7<36 7
Cell Phone: � ' -7'7 Y ri 6 7 Fax: '17c) ` (- 3 % 3 E-mail Address: fi/M 134(1411 q P l�, ltfLa
Parcel ID 0 (available from assessor's office //
at 920-5160 or at www.pitkinassessor,orq) b -
Street address of property i g g 6 A O MD
Legal Description: Lot 1-2- ,Block Fling ,Subdivision %no�rZ`r p
Size of lot: �� acres. Type of proposed stricture: AA 9 (ICS 6 i,
Total square Leet of hoose ft of bedrooms (potential) in house
Caretaker Unit Attached ( ) Detached ( )
Total area(ssq. ft.) of
Permit is for. New Horne ( ) Repair due to failure ( ) Remodel/Addition (►/t Emergency use( )
Water: Private well ( ) Spring ( ) Stream ( ) Community/Public Water System( W11
If community system: Name of system L,a-Z'f O
The fee for a ISDS application is $600 for a permit that takes 6 hours or less for the department to approve. If approval takes
longer than 6 hours, a rate of $100 per hour will be charged. The maximum fee is $1000. The basic fee of $600 is due at the
time of application. The remainder, if any, will be due in two stages: first at the time of issuance of the ISDS pemrit: second,
before final approval of rhe [SDS permit.
Application for an individual sewage disposal system is hereby submitted. I hereby certify that the above information is true and
accurate and that I have provided true and accurate information on locations of all existing and proposed wells, contour
intervals, buildings, property fines, ditches, slopes, waterlines, springs, suction or irrigation rines, drinking water cisterns, drain
tiles, irrigation ditches, lakes, water courses, streams, fleoodplains, dry gulches, and existing septic systems. I hereby certify
that any such features rot shown on attached site map are not present. Issuance of the permit does not imply the approval of
any other permit required for construction pursuant to Pipkin County codes. No construction may be undertaken until all
approvals and permits have been obtained.
r
The Pitkin County Environmental Health Department, Pitkin County and employees of these agencies will be held harmless
should the individual sewage disposal system fail or mal ction. The permit to construct is issued on information submitted by
the applicant or his/her representativ . T ner ass es full responsibility in case of failure of the system.
Signature of applicarnt Date
Received by & -Pz_ Receipt # 17 Date 3 OS
G:VsdsVsds appliclisdsapp Rev050103.doc
v.. �I
PITKIN ENVIRONMENTAL HEALTH DEPARTMENT
ISDS DESIGN CALCULATIONS
Owner's Name x' _ Parcel ID # .
House Size (sq. ft.) 's; ° (75 gpd, 100 gpd, or 130 gpd)
Number of Bedrooms in Main House
Number of Offices, Libraries, Studies, Similar -sized Rooms in Main House
Number of Bedrooms in Detached Caretaker unit
Number of Offices, Studies, Similar -sized Rooms in Caretaker Unit
(If the caretaker unit is ATTACHED, treat as if part of main house.)
Average Daily Waste Flow 520
State Review Required? no
Perc Rate # (T)
Design Flow (Q) = # potential bedrooms X 2 people/bedroom X gpd X 1.75
Q= 910
Minimum tank capacity 1137.5 gallons
Absorption Area (=Q/5 X SQRT perc rate)
MMI,
A= 1409.7659 sq. ft. of absorption area required
91 gravelless chamber units without reduction
# of Perc Holes Required: 3
1 in every soil type? Spaced uniformly over proposed area?
uQ ICK 4 9_8
A = 704.88297 sq.ft. with 50% reductionTRENCHES
72 gravelless chamber units with reduction
STANDARD
A= 704.88297 sq.ft. with 50% reductionTRENCHES
45 gravelless chamber units with reduction
EQ 36
44 EQ36 units in TRENCHES
SETBACK FROM WELL
# of feet = 100
SETBACK FROM POND, STREAM OR IRRIGATION DITCH
# of feet = 50
SETBACK FROM DRY GULCH
# of feet = 25
130
QUICK 4 9.2
sq ft 30% reduction BED
107 chamber units with re
986.83616 sq ft 30% reduction BED
64 chamber units with reduc.
79 EQ36 units in a BED
P. 1
CONICATION RESULT REPORT ( NOV. 10. 2r -:,v 4:49PM ) * * *
FAX HEADER: ENVIRO HEALTH NAT RESOURCE
TRANSMITTED/STORED : NOV.10.2006 4:47PM
FILE MODE OPTION ADDRESS RESULT PAGE
--------------------------------------------------- - -- -------------------
784 MEMORY TX 9639003 OK 2/2
SGM OK 2/2
----------------------------------------------------------------------------------------------------
REASON FOR ERROR
E— 1) H A N G Up
OR LINE FAIL E-2 ) BUSY
E-3) NO ANSWER E-4) NO FACSIMILE CONNECTION
..c' Nw.h
4D 40 l'1hI���II� !'
PITKIN COUNTY ENVIRONMENTAL HEALTH 81: NATURAL RESOURCES
DATE: 11/10/2006
Send to. David Powell From: Alicia Gomez
Fax Number: 963-9003 Phone Number: 9ZO-5087
CC: SGM Number of Pages, Including Cover: Z
CC Fax Number:
Cl URGENT Cl REPLY ASAP Cl PLEASE COMMENT O PLEASF REVIEW IM FOR YOUR
INFORMATION
COMMENTS:
A septic permit (# 05045) has been issued for parcel 2645-033-01-
012, 1880 Lazy O Road, owner Wallison. Please feel free to call 920-
5070 if you have any questions.
NOTE: Effective April 8, 2006 a licensed installer must install the
ISDS system and EH/NR must be notified prior to installation who
that person/company is to check for installer's compliance with our
new regulations.
fax cover
Pitkin County Environmental Health and Naturai Resources
0405 Castle Creek Road Suite #10, Aspen, CO 81611
Phone (970) 920.5070 1 Fax (970) 920.5077
Web site www_aspenpitkin.com/ehnr
M
SCHMUESER I GORDON 1 MEYER
ENGINEERS S. SURVEYORS
Carla Osberg
Pitkin County Environmental Health
0405 Castle Creek Road
Suite 10
Aspen CO 81611
October 31, 2006
RE: ISDS I.ot 12, Lazy O Ranch
Dear Carla;
E40
GLENWOOD SPRINGS ASPEN
I 1 B w. 6TH, SurrE 200 P.O. BOX 2 1 SS
GLENWOOD SPRINGS, CO B 160 1 ASPEN, CO 8 1 6 1 2
970-945-1004 970-925-6727
Fx: 970-945-5948 Fx: 970-925-4157
The purpose of this letter is to provide documentation that the above referenced ISDS was
installed per plans dated 8-5-05 and permit #05045 issued by Environmental Health. The
construction of the system was observed prior to backfill and was acceptable. The dosing siphon
operation was also observed and appeared to have adequate pressure and distribution throughout
the entire leachfield area. The installation of the ditch liner is complete.
In the attached as -built of the constructed system you will note that the location of the septic tank
and dosing siphon was adjusted slightly to minimize disturbance to the surrounding landscape.
Otherwise the system was installed as originally designed and approved.
Please do not hesitate to contact me should you have any questions.
Sincerely,
:UESER GO N MEYER, INC.
l
Dan Cokley, P.E.
CC: Wallison
Paul Gruner, Valley Excavating
p�T�`aly npj, r � 12406
R iXy� TURA) ' NMENT,
R'FS0URCfs
I:\2004\2004-307\10-17-06 ISDS ltr.doc
im
OWESTERN SLOPE AGGREGOES
INVOICE
ACTID ORDER DATE TICKET VEHID
MTL
gETWT
CHCS
TAX
DLV
TOTAL
VALLE2 12& COLOR 8/24/06 148450 HB2
34SR
15.15
106.05
4.14
0.00
110.19
1 LOADS FOR
12& COLORAD
15.15
106.05
4.14
0.00
110.19
VALLE2 12TH STREF 8/23/06 148257 HB2
34RB
14.18
101.39
3.95
0.00
105.34
I LOADS FOR 12TH STREET
14.18
101.39
3.95
0.00
105.34
VALLE2 ASPEN VILI 9/14/06 147093 VALI 34SR
14.95
104.65
4.08
OM
108.73
1 LOAM FOR ASN VILLA_
14.45
14rigis
4.
0.00
10&73
VALLE2 _ GLEN ELEC 8/24/06 148477 HB2 34SR
14.75
103.25
4.03
0.00
107.28
I LOADS FOR GLEN ELECTR 14.75 103.25 4.03 0.00 107.28
VALLE2
WALLASON 8/28/06
148802
HB2
WS
15.91
270.47
10.55
0.00
281.02
VALLE2
WALLASON 8/28/06
148789
VALI
WS
15.06
256.02
9.98
0.00
266.00
VALLE2
WALLASON 8/28/06
148808
VAL1
WS
14.52
246.84
9.63
0.00
256.47
VALLE2
WALLASON 8/29/06
149057
HB2
WS
14.76
250.92
9.79
0.00
260.71
VALLE2
WALLASOI` 8/29/06
149030
HB2
WS
14.33
243.61
9.50
0.00
253.11
VALLE2
WALLASON 8/28/06
148819
H132
WS
15.37
261.29
10.19
0.00
271.48
VALLE2
WALLASON 8/25/06
148610
HB2
WS
14.69
249.73
9.74
0.00
259.47
VALLE2
WALLASON 8/29/06
149001
1-1132
WS
14.56
247.52
9.65
0.00
257.17
VALLE2
WALLASOIN 8/28/06
148835
H132
WS
15.12
257.04
10.02
0.00
267.06
VALLE2
WALLASON 8/29/06
148961
H132
WS
14.44
245.48
9.57
0.00
255.05
VALLE2
WALLASON 8/25/06
148588
VALI
WS
14.18
241.06
9.40
0.00
250.46
VALLE2
WALLASON 8/28/06
148847
VAL1
WS
14.06
239.02
9.32
0.00
248.34
VALLE2
WALLASON 8/28/06
148852
HB2
WS
15.51
263.67
10.28
0.00
273.95
VALLE2
WALLASON 8/29/06
148938
HB2
WS
15.53
264.01
10.30
0.00
274.31
VALLE2
WALLASON 8/29/06
148915
1-1132
WS
15.74
267.58
10.44
0.00
278.02
VALLE2
WALLASOS 8/28/06
148824
VALI
WS
14.68
249.56
9.73
0.00
259.29
*0"16
LOADS FOR
WALLASON
238.46
4,053.82
158.09
0.00 4,211.91
%/ I
qyq Z
20
LOADS FOR
VALLE2
297.49
4,469.16
174.29
0.00
4,643.45
Grand Total: 297.49 4,469.16 174.29 0.00 4,643.45
�---
Ar
w
195
oe
-All
41-
J4
40" 6
A6
00
T"�
fl L l10lox 1844
E se t
Glenwood Springs, CO 81602
SEBY�C1 W.W Ph 970-618-5033
[ Fax 303-216-2796
July 18, 2005 Project No. 1074
Frieda Wallison
1880 Lazy -O -Road
Snowmass, Colorado 81654
Percolation Test, Existing Residence
1880 Lazy -O -Road
Pitkin County, Colorado
Frieda,
RECEIVED
JI -11 � 5 2005
PITKIN COUNTY
ENVIRONMENTAL HEALTH
(.nc 14(2 v � o9
As requested, ALL SERVICE septic, LLC, performed a second percolation test for 1880 Lazy -0 -
Road, Pitkin County, Colorado.
EXISTING CONDITIONS AND STRUCTURES
The subject property is located in a rural area where Onsite Wastewater Systems (OWS) are
necessary. There is an existing residence that is served by an OWS located to the north of the
residence. The percolation holes were placed north of the residence, as requested by Schmueser
Gordon Meyer, Inc. The slope at the area of the percolation holes is 4-5% to the north, and vegetation
consists of a thick: cover of grasses. There is a water ditch running north of the percolation area.
SUBSURFACE
The subsurface was investigated by digging one profile hole and 3 percolation holes, at the locations
indicated on Figure 1. The materials in the profile hole consisted of a 6 -inch root zone, underlain by
sandy clay, with Mancos Shale Bedrock Fragments to 3.5 feet, underlain by Mancos Shale Bedrock to
the maximum depth explored of 9 feet. Ground water was not encountered. Percolation rates ranged
from 80 minutes per inch (MPI) to 40 MPI, with an average rate of 54 MPI.
LIMITS:
Results are based on field investigations and data provided by the client. If soil conditions
encountered are different from conditions described, ALL SERVICE septic, LLC should be notified
Please call with questions.
ALL SERVICE septic, LLC Reviewed By: o�Oq►1,00
rn
Timothy R. Petz ?Richard H. P.
38662
3 copies
Fax copy to 970-925-5948, Attn: Dan Cokiey �FJ,s/0* $ X
«..•
NAL E�
SITE PLAN AND LOCATION OF
PERCOLATION HOLES
PROPERTY LINE—
/ BLUE PROPERTY STAKE
/
-
Q�---------------------
. O
O O ,PROFILE PIT
O P-1
cl) P-3 P-2
O
EXISTING WALLISON
LOT 12 RESIDENCE
i
APPROXIMATE
SCALE
1"=50'
NORTH
1880 LAZY -O -ROAD ALL PRO NO. 1074
PITKIN COUNTY, COLORADO SERVICE SEPTIC, LLC
970-618-5033 FIGURE 1
PIITKIN COUNTY ENVIRONMENTAL HEALTH DEPARTMENT
Percolation Test and Soils Data Form - TABLE 1 - PROJECT 1074
1880 Lazy -O -Road - Pitkin County, Colorado
PROFILE PIT Date of Test: 7-11-05
0 - 6" Topsoil, Root Zone
6" - 3.5' Clay, Sandy, Very Stiff, Moist, Grey/Brown (Bedrock Fragments)
3.5' - 9' Weathered Mancos Shale Bedrock, Medium Hard, Moist, Grey
No Groundwater Encountered
Hole Hole Interval
Measurement at
Measurement at
Change (in.) Percolation Rate
No. Depth (in.) (min.)
Start of Interval
End of Interval
(min./in.) MPI
20
(in.)
(in.)
0.75
20
6.25
6.50
0.25
1 33 20
3.50
4.75
1.25
20
4.75
6.00
1.25
20
6.00
7.00
1.00
20
7.00
7.50
0.50
20
7.50
8.00
0.50
20
8.00
8.50
0.50 40
2 31 20
2.50
4.25
1.75
20
4.25
5.50
1.25
20
5.50
6.25
0.75
20
6.25
6.50
0.25
20
6.50
7.00
0.50
20
7.00
7.25
0.25 80
3 35 20
3.50
4.25
0.75
20
4.25
5.00
0.75
20
5.00
5.50
0.50
20
5.50
6.25
0.75
20
6.25
6.75
0.50
20
6.75
7.25
0.50 40
AVERAGE = 54 MPI
1.
2
3.
4.
5.
6.
7.
8.
t.
2
3.
4.
5.
6.
7.
8.
9.
THIS DRAWING SHOWS ALL EXISTING WELLS WI M SETBACK
DISTANCES (WCLUDWG ON SURROUNDING PROMRM CONTOUR W TERVALS,
ALL PROPOSED AND BMW BUHDRM.S PROPERTYLNE$ DI7LHE.% SLOPES
OF GREAMIR THAN 1= 1WITER UIE'S, SPRINKLER SYSTEMS, 5F'RINGS SUCTION
(IRRIGATION) LINES DRINKING WATER CISTERNS, DRAIN TILES IRRIGATION DITCHES,
LAKES, POND$ WATER COURSES STREAMS FLOODPLANS, FLOODWAYS, DRY
GULCHES, OR EXISTING SEPTIC SMEMS, AND ALL SUCH FEATURES ON
NEIGHBORING PROPERTIES WITHIN SETBACKS
JGV IIVI� O Ir�tL lnnl
lar m scvc am wr vartrF
A. CALCULATIONS Quick4 BED ...��
PERCOLATION RATE = 133 NPI AVC. (ALL SERVICE' SEPTIC PRO.ECT NO. 1074) /
DESIGN FLOW = 2 EEOROUts X 2 X TM x1.75 = 910 GALLONS PER DAY (> 6.000 SF RESIDENCE)
REQUIRED SEPTIC TANK CAPACITY r 910 X 1.25 = 1138 GALLOWS
USE ONE - 1,250 GALLON, TWO COMPARTMENT CONCRETE SEPTIC TANK
ABSORPTION BED AREA REQUIRED =\
LIAR - 0.2 (gal/si/day)
A=Q/LTAR=910/0.2-4550 SF
Oukk4 BED INSTALLATION:
4550 SO. FT. / 9.2 SQ.FT. PER UNIT = 495 EQUIV. UNITS MIN = 5605 EQUIV AREA
WSTALL 3 BEDS (7 UNITS WOE x 23 UNITS + 2 ENDCAPS LONG) => 3 x 7(2.83) x [23(4) + 2(t.33)j = 5633 SF
f000�
NEU SETBACK DISTANCE - 100 FEET
DITCH, STREAM AND POND SETBACK DISTANCE = 50 FEET
WATERLINE SETBACK DISTANCE
10 FEET TO TANK, 25 FEET TO FIELD
0�S I
L
cil
A9r'cU�tUr 1146
�i
Ttff Ov(dc4 BEDS SHALL BE LEVEL(+/ a I FEET). — — —
ON NATURAL GROIIJD LNOT M FlLL) AND BAC( FILL
MUST PROVIDE Posln DRAINAGE AWAY FROM THE BED SYS717A. I �\
THE SEPTIC TANK SHALL BE LOCATED AT LEAST FIVE FEET AWAY FROM THE RESIDENCE
k 4' DEEP MAX TO TOP OF TANK. \
THE PIPE FROM THE RESIDENCE TO THE TANK MUST BE INSTALLED AS FOLLOWS:
THE PIPE MUST BE INSTALLED STRAIGHT IN ALIGNMENT AND GRADE.
IF A CHANCE IN ALIGNMENT OR GRADE IS NECESSARY, A CLEANOUT 4WLL BE REQuIRm AT THE CHANCE Q �"' \ \ �\ \ \ 1T J -
THE MINIMUM GRADE OF THE PIPE MUST BE 1/4' PER FOOL % :
THE PIPE MUST BE A MINIMUM OF ASTM 3034 PVC PIPE \�� \\ ,� ` \\ \
A MINIMUM OF 1 CLEANOUT SHALL BE INSTALLED AT THE LOCATION NIERS THE PIPE LEAVES THE RESMCE �% % °)fp \' ^ \�\ \\ % • �,� \ / /
THE PIPE SHALL BE A MINIMUM OF 4" IN DIAMETER.
THE PIPE FROM THE SEPTI: TANK TO THE Oukk4 BED SYSTEM MUST BE INSTALLED AS FC10W5: \•1 /
THE FIRST IO' MUST BE SCFED.40 PVC. 0
THE MINIMUM SLOPE OF THE LINE MUST BE 1/4" PER F007.
THE PIPE SHALL BE A MINIMUM OF ASTM 30.34 PVC PIPETHE PIPE SHALL BE A MINIMUM OF 4" IN DIAMETER.
USE RISERS TO BRING THE SEPTIC TANK ACCESS WITHIN 6" OF FINAL GRADE
ALL MAMMALS, INSTALLATION PRACTICES AND SETBACK REQUIREMENTS SHALL
COMPLY WITH PITKIN COUNTY WDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS.
Quick* COMPONENTS TO BE INSTALLED IN ACCORDANCE NTH MANUFACTURERS RECOMMENDATIONS
PROVIDE INSPECTION PORTS AT THE CORNERS OF EACH 8E0. I i \\
PROVIDE REMOVABLE 4" ORENCO EFFLUENT FILTER IN SEPTIC TANK & EXTEND HANDLE TO VV/IN t" OF RISER LID.
1 I rsLOCA OV4V4Ws \vvi
I i \ /E7�Snl G
LEACH1iIELD ` \ /
AE7YT�- o 1 I ATE
I CAV 2O'OfYpyp A t Ar
1 \ ("'7. 'YIN' f� V 11
t7ESEp'AC �•\ � t \\\ \ \ � / \ � � .111, \.,
_.__.. l loo► - PAO R I WDIIJe i
ams
mocuo
• Wryl L
\ ♦ NEW LEACH
ole
TING TIC
SEPTIC'
� � I
IL
J
\\ LOT
MjTTcuiturd Lands
i
1/
`T_
11111 11 1 I 1 I
\ 1111 1%
---- — `\ 1 1 1 \ 1
A.
FLED / �' / � \\\\\\\\\\\ \ � /•�
-_—' _• = /,�� Agricultural Land
0C.
SEPTIC TANK DETAIL
N07 TO -ALE
2„
=481,
FFEr_TIVE IFNGT )
NOL
WATERLINE CROSSINGS REQUIRE THAT THE DRINKING WATER OR
WASTEWATER PIPE BE ENCASED FOR AT LEAST TEN (10) FEET
OF EACH SIDE OF THE CROSSING OR PLACE WHERE COMPONENTS
ARE CLOSER THAN TEN (10') FEET. PIPE OF SCHEDULE 40 RATING
OR BETTER MUST BE USED, OF SIffHXNT DIAMETER TO EASILY
SLIDE OVER AND COMPLETELY ENCASE THE LINE RIGID END CAPS
OF AT LEAST SCHEDULE 40 RATING MUST BE GLUED OR SECURED
IN A WATERTIGHT FASHION TO THE ENDS OF THE ENCASEMENT
PIPE THF$ MUST BE A HOLE OF SUFFICIENT SIZE TO ACCOMMODATE
THE PIPE IN THE LOWERMOST SECTION OF THE RIGID CAP SO THAT
THE CONVEYANCE PPE RESTS ON THE BOTTOM OF THE ENCASEMENT
PIPE. THE AREA IN WHICH THE PIPE PASSES THROUGH THE EMDCAPS
MUST BE SEALED WITH AN APPROVED UNDERGROUND SEALANT
COMPATIBLE WITH THE PIPING USED.
COPYRIGI-IT
=DA
v +.
�
-a
.�• .. A,.
�-0
oo
D
`�
.
a
N
°
m
° 0 �A . y
o
s
n
= .,�.
„
. ,
gUILI)lt NJf 0-
f - 4" SC�H.MANIFOLD (LEVELS
/ "� COORDINATE RELOCATION
1131fl. OF IRRIGATION. -SYSTEM
WITH HOMEOWNER & RANCH
MANAGER. IS6S AREA SHOULD f
NOT BE PART OF FUTURE
IRRI GA TED AREA.
4" SCH. 40 PVC 0 MIN. 29 GRADE,
PROVIDE MIN. 5' COVER
� [3
OF FIED
I FLOV2INE
TY CA?-- _
10' M1tI.
18'
FL OF -30= -EMP
ELEV. = 7296.18' _
\
-L OF CM
= 72
LEV. 9 ,. 1
1\7
Q - UICK4 IN �' TO,R UNIT
W/2"0 PVC_ DIS TION PIPING _-_-
" PERF. -@.4' C=C A 1 -0-,.,R 2 o'clock (AL TERN
PROVIDE WEEP HOLE --AT EA END OF RUN. ,1
DOSING SIPHON MANHOLE (4'0)
RIM = 7331.0, INVERT = 7324.3
INSTALL FLUID DYNAMICS MODEL 417
HIGH WATER LEVEL == 7328.0
LOW WATER LEVEL = 7326.6
DOSING VOLUME = 130 GALLONS
VERIFY ALL ELEVATIONS AT
TIME OF CONSTRUCTION.
3
)-0
10-
T,
RESIDENCE
EXISTING
SITE PLAN
F[ OF 1 CMP
ELEV.= 730,3W-'
"\F 18 " CMP
ELE . -- 7304��185'
\
EXI TING
LEAC FIELD
AREA
ti
3
40--PVC-0 40--PVC-0
PROVIDE
EXISTING
EL
f.
RAV tVEWAY
SEWER CLEANOUT
!y �00t.
1 00000
LOCATE SEWER CLEANOUT AT ALL
HORIZONTAL AND/OR VERT/CAL
CHANGES IN DIRECTION
45 PVC
4 " PVC WYE OR
ELBOW
FLOW
2" PVC PERFORATED PIPE
CLASS 160, a " PERF. AT 48"
C -C. SLOPE 0 1/8" PER
FOOT TO END OF PIPE.
\ 2
1
12"1 .
PLUG
CLEAN-OUT DETAIL-
FINISHED
GRADE
PROVIDE POSITIVE
DRAINAGE OFF MOUND
INFIL TRA TOR Q4 UNIT (6 WIDE
INSTALL PER MFG REC.
TOPSOIL FILL
O J
-= y8'
�. p•.•--24 " SAND AS
SPEC.
45 PVC
ELBOW
FL OW
GENERAL NOTES:
1. ALL MATERIALS, INSTALLATION PRACTICES, SETBACK REQUIREMENTS, ETC., SHALL COMPLY
WITH THE PITKIN COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS.
2. THE MOUND SHALL BE CONSTRUCTED SO THAT THE BOTTOM IS LEVEL +/-0.1'. PLACE
BED IN NATURAL GROUND; NO PORTION OF THE BED SHALL BE PLACED IN FILL.
3. PROVIDE ADEQUATE SURFACE & SUBSURFACE WATER DIVERSION TO ASSURE THAT
RUN-OFF DOES NOT ENTER THE BED IF SUBSURFACE WATER IS ENCOUNTERED, NOTIFY
ENGINEER.
4. PIPING IN SYSTEM SHALL BE STANDARD 2" PVC CLASS 160 PRESSURE PIPE, A SINGLE
ROW OF 1/8"0 HOLES, SPACED AT 48" SHOULD BE DRILLED IN PIPE. (LOCATE HOLES TO
SPRAY TO CROWN OF UNIT) PROVIDE CAP AT END OF EACH LINE AND WEEP HOLES FACING
DOWNWARD.
5. SAND SHALL BE 0.04 TO 0.28 MM EFFECTIVE SIZE WITH A UNIFORMITY COEFFICIENT OF 4
OR LESS. PROVIDE SIEVE ANALYSIS TO ENGINEER FOR REVIEW.
6. THE RECOMMENDED BED SEEDING IS SALT RESISTANT FESCUE AT 4 TO 6 LBS. PER
1000 SQ.FT. ALL OTHER AREAS DISTURBED BY CONSTRUCTION SHALL BE RESEEDED
WITH NATIVE GRASSES TO PREVENT EROSION.
7. THE LOCATION OF THE BED MAY BE ADJUSTED IN THE FIELD TO BETTER FIT THE SITE,
PROVIDED ALL SETBACKS ARE MET. CONTRACTOR SHALL VERIFY LAYOUT ACCOMMODATES
SITE SLOPE.
8. 4" PVC TEES SHOULD NOT BE GLUED TO ENABLE OBSERVATIONS OF WATER LEVEL IN
SYSTEM AND TO REMOVE EXCESS SALTS ACCUMULATION OR SURPLUS WATER, IF NECESSARY.
PROVIDE INSPECTION PORTS AT EACH CORNER OF BED.
9. USE RISERS AS NEEDED TO BRING SEPTIC TANK ACCESS HATCH WITHIN 6" OF FINISHED
GRADE. INSTALL ORENCO 4" EFFLUENT FILTER & EXTEND HANDLE TO WITHIN 1" OF RISER
LID.
10. SDR 35 PVC PIPE OR PIPE OF EQUAL STRENGTH OR OTHER PIPE PROPERLY
SUPPORTED TO PREVENT FAILURE BY SETTLING SHALL EXTEND FROM ALL TANKS FOR A
DISTANCE OF AT LEAST FIVE FEET (5) FROM THE INLET AND OUTLET ENDS.
11. THE CONTRACTOR AND OWNER SHALL TAKE WHATEVER MEASURES ARE NECESSARY TO
ASSURE THAT (a) SEPTIC TANK AND SEWER LINES ARE COMPLETELY WATER TIGHT, AND (b)
THE SYSTEM /S TO BE INSTALLED TO PREVENT FREEZING OF ALL PRESSURE AND GRAVITY
SEWER LINES.
12. THE P17KIN COUNTY ENVIRONMENTAL HEALTH DEPARTMENT AND THE ENGINEER SHALL BE
NOTIFIED WHEN CONSTRUCTION COMMENCES AND KEPT ABREAST OF THE CONSTRUCTION
PROGRESS SO THAT SUFFICIENT INSPECTION CAN BE PERFORMED TO ASSURE CONFORMANCE
WITH THESE PLANS. PROVIDE:" A MINIMUM OF 48 HOURS NOTICE TO EACH.
13. THE SURFACE OF EACH BED SHALL BE PROPERLY MOUNDED PER THE DRAWINGS TO
ENSURE THAT PRECIPITATION OR SNOWMELT WILL RUN OFF THE BED.
14. SURFACE GRADING SHALL ROUTE RUNOFF AROUND AND AWAY FROM THE BEDS.
15. CONTRACTOR RESPONSIBLE FOR THE REVEGETATION OF ALL DISTURBED AREAS
DESIGN CALCULATIONS.•
1. 2 BEDROOM ADDITION TO EXISTING HOME (>6000 SF),
USE 2 PERSONS/BEDROOM AND 130 GPCD.
2. DETERMINE FLOW.-
Q = (2)(2)(130) = 520 GPD
DESIGN Q = 1.75 * 520 = 910 GPD
J SEPTIC TANK.
V = 910 GPD * 1.25 = 1138 GALLONS; INSTALL 12500 GALLON TANK
4. ALLOWABLE LOADING RATES.•
PERC TEST RESULTS. 60 MINUTES/INCH (AVERAGE,)
5. DETERMINE BED SIZE -
FOR ABSORPTION.- Areo = 0/5 * SORT(60) = 1410 SF
309 REDUCTION.- 1410 SF * .7 = 987 SF
USE QUICK4 UNITS.- 987 SF / 9.2 SF/UNIT = 108 UNITS
INSTALL IN 6 UNIT x 18 UNIT BED (18'x72)
6. SHALE BEDROCK AT 3 FEET, USE 24" OF SAND TD PROVIDE
48" OF SUITABLE SOIL IN MOUND CONFIGURATION.
TOP EDGE OF BED (MIN.) ±7811
IP�OF SAND/INFILTRATORS ±7810
ASSORPT/ EI�EL ±7809
12 \
BOTTOM OF SAND ±780
N
IST. GRADE VARIES
APPROX. LEVEL OF SHALE
TOPSOIL BELOW PROPOSED BEDROCK (±3' DEPTH)
SHALL BE REMOVED PRIOR TO
SYSTEM CONSTRUCTION
MOUND SECTION
NOT TO SCA L E
i
Vii. ,,`c0!N
S C H M U ES E R GORDON M EYE R
NUM-
BER REVISION DATE BY J
ob. 2004-307.001 z
1 1 8 W. 6TH STREET, SUITE 200
by• DJC y
GLENWOOD SPRINGS, COLORADO 8 1 601 INDIVIDUAL SEWAGE
WALLISON RESIDENCE1 1
(970) 945-1004 FAX (970) 945-5948 08 05 05 "
ASPEN, COLORADO (970) 925-6727 DIPSOSAL SYSTEM
SCHMUESER I GORDON � MEYER CRESTED BUTTE, CO (970) 349-5355
MH FRAME AND COVER
HS20 LOADING RATED OR EQUAL
NON -SHRINK
RING & COVER -SET TO
GROUT \
PARALLEL FINISHED SURFACE
\\\
LEV. 7331.0
ADJUST TO REQUIRED GRADE WITH A
MAXIMUM OF SIX -2" THICK REINFORCED
xQ
CONC. GRADE RINGS SET IN NON -
00
SHRINK GROUT
d -
ECCENTRIC CONE
"
V-9"
PRECAST ECCENTRIC CONE
2' HIGH WITH WALL
^ MAX
THICKNESS OF 6" ;
iv
AT TOP TO 5' AT
"' I
INSTALL 1" DIAMETER DOUBLE RAM-NEK
BOTTOM
16TMP.
9
°° (OR EQUAL) JOINT GASKET AND GROUT
6„
JOINTS INSIDE AND OUTSIDE, GROUT LIFT
HOLES ON INTERIOR, INSTALL 1 1/2"
DIAMETER RAM-NEK ON MANHOLES
MANHOLES LARGER THAN 48"
w
4 " PVC FROM
SEPTIC TANK
4'-0" DIA
a
°7
ELEV. 7328.0
°
PRECAST REINFORCED CONCRETE
0I
5" MIN
MANHOLE BARREL PER ASTM -C478
WITH STEPS
w
d
FLUID DYNAMICS //417 AUTO SIPHON
ALL MANHOLE STEPS
PLASTIC COATED
MA INDUSTRIES
INSIDE LIP TO BE HIGHER
OR EQUAL
THAN OUTSIDE LIP
LEV. 7326.68" PVC PIPE TO
d
��-� DISTRIBUTION MANHOLE
ELEV 7325.0
o
PIPE PENETRATION GASKET
°d
PLACED IN CORE TO ACCEPT
N
PIPE: KOR-N-SEAL, A-LOK,
OR EQUAL
d
EL324.3
° PRE -CAST MANHOLE BASE AND
y
IN
FIRST BARREL SECTION CAST
MONOLITHIC ASTM -C478
MIN 12" COMPACTED 3/4
SCREENED ROCK
GENERAL NOTE
1. ALL CONCRETE WORK SHALL COMPLY WITH LATEST
ACI -318 SPECIFICATIONS
DOSING
SIPHON MANHOLE
LOCATE SEWER CLEANOUT AT ALL
HORIZONTAL AND/OR VERT/CAL
CHANGES IN DIRECTION
45 PVC
4 " PVC WYE OR
ELBOW
FLOW
2" PVC PERFORATED PIPE
CLASS 160, a " PERF. AT 48"
C -C. SLOPE 0 1/8" PER
FOOT TO END OF PIPE.
\ 2
1
12"1 .
PLUG
CLEAN-OUT DETAIL-
FINISHED
GRADE
PROVIDE POSITIVE
DRAINAGE OFF MOUND
INFIL TRA TOR Q4 UNIT (6 WIDE
INSTALL PER MFG REC.
TOPSOIL FILL
O J
-= y8'
�. p•.•--24 " SAND AS
SPEC.
45 PVC
ELBOW
FL OW
GENERAL NOTES:
1. ALL MATERIALS, INSTALLATION PRACTICES, SETBACK REQUIREMENTS, ETC., SHALL COMPLY
WITH THE PITKIN COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS.
2. THE MOUND SHALL BE CONSTRUCTED SO THAT THE BOTTOM IS LEVEL +/-0.1'. PLACE
BED IN NATURAL GROUND; NO PORTION OF THE BED SHALL BE PLACED IN FILL.
3. PROVIDE ADEQUATE SURFACE & SUBSURFACE WATER DIVERSION TO ASSURE THAT
RUN-OFF DOES NOT ENTER THE BED IF SUBSURFACE WATER IS ENCOUNTERED, NOTIFY
ENGINEER.
4. PIPING IN SYSTEM SHALL BE STANDARD 2" PVC CLASS 160 PRESSURE PIPE, A SINGLE
ROW OF 1/8"0 HOLES, SPACED AT 48" SHOULD BE DRILLED IN PIPE. (LOCATE HOLES TO
SPRAY TO CROWN OF UNIT) PROVIDE CAP AT END OF EACH LINE AND WEEP HOLES FACING
DOWNWARD.
5. SAND SHALL BE 0.04 TO 0.28 MM EFFECTIVE SIZE WITH A UNIFORMITY COEFFICIENT OF 4
OR LESS. PROVIDE SIEVE ANALYSIS TO ENGINEER FOR REVIEW.
6. THE RECOMMENDED BED SEEDING IS SALT RESISTANT FESCUE AT 4 TO 6 LBS. PER
1000 SQ.FT. ALL OTHER AREAS DISTURBED BY CONSTRUCTION SHALL BE RESEEDED
WITH NATIVE GRASSES TO PREVENT EROSION.
7. THE LOCATION OF THE BED MAY BE ADJUSTED IN THE FIELD TO BETTER FIT THE SITE,
PROVIDED ALL SETBACKS ARE MET. CONTRACTOR SHALL VERIFY LAYOUT ACCOMMODATES
SITE SLOPE.
8. 4" PVC TEES SHOULD NOT BE GLUED TO ENABLE OBSERVATIONS OF WATER LEVEL IN
SYSTEM AND TO REMOVE EXCESS SALTS ACCUMULATION OR SURPLUS WATER, IF NECESSARY.
PROVIDE INSPECTION PORTS AT EACH CORNER OF BED.
9. USE RISERS AS NEEDED TO BRING SEPTIC TANK ACCESS HATCH WITHIN 6" OF FINISHED
GRADE. INSTALL ORENCO 4" EFFLUENT FILTER & EXTEND HANDLE TO WITHIN 1" OF RISER
LID.
10. SDR 35 PVC PIPE OR PIPE OF EQUAL STRENGTH OR OTHER PIPE PROPERLY
SUPPORTED TO PREVENT FAILURE BY SETTLING SHALL EXTEND FROM ALL TANKS FOR A
DISTANCE OF AT LEAST FIVE FEET (5) FROM THE INLET AND OUTLET ENDS.
11. THE CONTRACTOR AND OWNER SHALL TAKE WHATEVER MEASURES ARE NECESSARY TO
ASSURE THAT (a) SEPTIC TANK AND SEWER LINES ARE COMPLETELY WATER TIGHT, AND (b)
THE SYSTEM /S TO BE INSTALLED TO PREVENT FREEZING OF ALL PRESSURE AND GRAVITY
SEWER LINES.
12. THE P17KIN COUNTY ENVIRONMENTAL HEALTH DEPARTMENT AND THE ENGINEER SHALL BE
NOTIFIED WHEN CONSTRUCTION COMMENCES AND KEPT ABREAST OF THE CONSTRUCTION
PROGRESS SO THAT SUFFICIENT INSPECTION CAN BE PERFORMED TO ASSURE CONFORMANCE
WITH THESE PLANS. PROVIDE:" A MINIMUM OF 48 HOURS NOTICE TO EACH.
13. THE SURFACE OF EACH BED SHALL BE PROPERLY MOUNDED PER THE DRAWINGS TO
ENSURE THAT PRECIPITATION OR SNOWMELT WILL RUN OFF THE BED.
14. SURFACE GRADING SHALL ROUTE RUNOFF AROUND AND AWAY FROM THE BEDS.
15. CONTRACTOR RESPONSIBLE FOR THE REVEGETATION OF ALL DISTURBED AREAS
DESIGN CALCULATIONS.•
1. 2 BEDROOM ADDITION TO EXISTING HOME (>6000 SF),
USE 2 PERSONS/BEDROOM AND 130 GPCD.
2. DETERMINE FLOW.-
Q = (2)(2)(130) = 520 GPD
DESIGN Q = 1.75 * 520 = 910 GPD
J SEPTIC TANK.
V = 910 GPD * 1.25 = 1138 GALLONS; INSTALL 12500 GALLON TANK
4. ALLOWABLE LOADING RATES.•
PERC TEST RESULTS. 60 MINUTES/INCH (AVERAGE,)
5. DETERMINE BED SIZE -
FOR ABSORPTION.- Areo = 0/5 * SORT(60) = 1410 SF
309 REDUCTION.- 1410 SF * .7 = 987 SF
USE QUICK4 UNITS.- 987 SF / 9.2 SF/UNIT = 108 UNITS
INSTALL IN 6 UNIT x 18 UNIT BED (18'x72)
6. SHALE BEDROCK AT 3 FEET, USE 24" OF SAND TD PROVIDE
48" OF SUITABLE SOIL IN MOUND CONFIGURATION.
TOP EDGE OF BED (MIN.) ±7811
IP�OF SAND/INFILTRATORS ±7810
ASSORPT/ EI�EL ±7809
12 \
BOTTOM OF SAND ±780
N
IST. GRADE VARIES
APPROX. LEVEL OF SHALE
TOPSOIL BELOW PROPOSED BEDROCK (±3' DEPTH)
SHALL BE REMOVED PRIOR TO
SYSTEM CONSTRUCTION
MOUND SECTION
NOT TO SCA L E
i
Vii. ,,`c0!N
S C H M U ES E R GORDON M EYE R
NUM-
BER REVISION DATE BY J
ob. 2004-307.001 z
1 1 8 W. 6TH STREET, SUITE 200
by• DJC y
GLENWOOD SPRINGS, COLORADO 8 1 601 INDIVIDUAL SEWAGE
WALLISON RESIDENCE1 1
(970) 945-1004 FAX (970) 945-5948 08 05 05 "
ASPEN, COLORADO (970) 925-6727 DIPSOSAL SYSTEM
SCHMUESER I GORDON � MEYER CRESTED BUTTE, CO (970) 349-5355