Loading...
HomeMy WebLinkAboutpitkin.eh.2164326201001 (2003)ltkl�l C 011llt� Environmental geaith NO SEPTIC PERMIT REQUIRED FORM �,P'F'� 017 T) Date: s Owner's Name: 0 /-11. `T /7A Project Name: M A r tj UD 1L S E i lV e 2l o n,- 'A -em o e - Address of Property: Building Permit number: Parcel ID # 2 —O —U4` Scope of Project: lV 7"P 2i ok C' A 0 D e � vrease the bedroom/potential bedroom count Remodel does not me p Existing septic system is sized for this project New buildings do not need a septic system (i.e. garage, shed, barn, etc.) Project is, not located in the area of the existing septic system No septic permit is required for this project. No further review is required by Environmental Health. FOOD SERVICE FACILITY This facility contains a retail food establishment. Environmental Health has reviewed and approved the plans. 0405 Castle Creek Road, Suite 10 Aspen, Colorado 8161 1 (970) 920-5070 fax 920-5077 www.pitl<ingov.com � 4 y: +p'4, hbdalNrdd yq� r�,' - vickim@co.pitkin.co.us, 03:19 PM 01/28/2004, 565 N. Starwood - Bricol Corp, John Silich To: vickim@co.pitkin.co.us From: Nancy MacKenzie <nancym@co.pitkin.co.us> Subject: 565 N. Starwood - Bricol Corp, John Silich Cc: Bcc: Attached: EH is okay to issue a building permit for the remodel for the addition of the elevator. The remodel has no impact on the existing septic system. Printed for Nancy MacKenzie <nancym@co.pitkin.co.us> 01/28/2004 10:39 9709253929 SILICH CONSTRUCTION PAGE 01/05 www, ani m nconuruc iron. cum To: Nancy Mackenzie From: John Silich Fax: 970.920.5070 Pages: 5 Phone: 970.920.5077 Date: 1/28/04 Re: Permit_ application for 565 N. Starwood Dr CC: Fax 0 Urgent 0 For Review ❑ Please Comment 0 Please Reply ❑ Please Recycle Nancy, Attached are the interior changes for 565 N. Starwood Drive. We are also doing an exterior remodel of the building veneers and replacing the existing roof. Please call with any questions. jM y Thanks, o n Silich. Slllch Construction' 304 South Galena Street, Suite 5 * Aspen CO, 81611 Phone: (970) 920-2299' Fax: (970) 925-3929' E-mail: jsilich®rof.net 01/28/2004 10:39 9709253929 SILICH CONSTRUCTION --PAGE 02/05 . i + � � }� Jam.. � ol 01/28/2004 10:39 9709253929 SILICH CONSTRUCTION PAGE 03/05 &�L,09_�ER LEVE PLAN (ne f I ' wa 7r m 01/28/2004 10:39 9709253929 ,SILICH CONSTRUCTION _ --------'--__- UNo� 01/28/2004 10:39 oil Apo_^2 add € yA �p y0 _ ■� Ya �Ze'� •uq � b 2 f� � r �tt ! R ! Eia3ae! 9qs; p i �s. r Permit # 02052 Type of permit Name of Owner Pitkin County Environmental Health Department Permit for an Individual Sewage Disposal System 0405 Castle Creek Road, Suite 10, Aspen, Colorado 81611 Phone 970-920-5070 / FAX 970-920-5077 Parcel ID # 2643-262-01-001 Remodel/Addition Bricol Corp N.V. Street Addressb` N. Starwood Property legal description Lot R17 Block A„ Original Starwood Size of lot 2.8 acres Total square footage of the house 5408 Water source Community/Public Water System # of potential bedrooms in 5 Caretaker unit detached Total square footage of the caretaker unit # of potential bedrooms in caretaker unit SIX: Guest house w/ 4 bedrooms & 1 office with % bath; 1 bedroom CDU Designed for what # rooms (list) 700 Permit information Designed by Church & Associates 4501 Wadsworth Blvd Wheat Ridge 80033 Perc rate 39 Profile hole depth 8 ft Depth to groundwater or bedrock +8 ft Minimum Septic tank capacity 2516 gallons Minimum Absorption area 2514 sq ft Comments Septic permit approved per compliance with the engineer design and specifications dated May 6, 2002. Any changes must be approved by this department and the design engineer prior to them being made. Design is for one 2000 gallon single compartment concrete tank followed by one 1000 gallon two-compartment tank with an effluent filter and six trenches 1 chamber wide by 14 chambers long (84 chambers total). Minimum horizontal distances between components of the system and physical features shall conform to the Pitkin County ISDS regulations. The engineer states the irrigation ditch must be lined for only 50 feet beyond the trenches because the field is below the irrigation ditch. The trenches must be a minimum of 10 feet away from the lined ditch. Ground water could be a concern. Trench depth is to be kept shallow. The engineer and this department must be called to inspect during the initial excavation for the system. This department does not endorse any brand of products. This permit must be kept on-site during installation. The engineer must do a final inspection of the installation and submit an as -built letter to this department. This department must also be called for an inspection with a minimum of 48 hours advanced notice. Permit approved by: ' '- 2a� Date: o =>- Plans and specifications of the p posed individual sewage disposal system have been reviewed and are considered satisfactory. Permission is hereby granted to the owner or the agent to perform the work indicated in accordance with the Pitkin County ISDS Regulation in effect at the time of issue. This permit becomes invalid 6 months from the date that the permit was issued unless system construction has commenced or an extension has been approved in writing by the Department. As -built drawings Tust be I cluded with this permit before the final approval will be issued. Installer:li"11r1ti�i�;�'`� -I Final inspection approval: C�k Date: t ,SCALE } f, r \1 30, LCT R1 7A, STARWOOD EXISTING DRAIN PITKIN COUNTY, COLORADO FIELD TO BE ABANDONED . 10' PROPERTY f + LINE SETBACK r ;t ,% _ r' r} I ; /CLEANOUT Yfly yy ( r1 1302 SF OF INFILTRATIVE AREA IN b t � 24" DIAK'1� . FLOW j GRAVELLESS CHAMBER -TRENCHES, EACH SPI.7f ITER BASIN TRENCH MUST HAVE I ROW OF 14 CHAMBERS 50 FT -Y FOR A TOTAL OF 84 CHAMBERS. TRENCHES y �• i ARE ANGLED TO CONFORM TO THE /' a TOPOGRAPHY USING 150 INFILTRATOR® CONTOUR- WEDGES. ''� , r r PROPOSED ! ' IRRIGATION DITCH MUST BE LINED WITHIN 50 FEET OF DRAT FIELD - !nR mn 1 A77nw . � / • `. , i � 5 -BEDROOM / REMODELall f 4"PVC 1 SEWER } LIVE SERVA N/VENT 83� 4" PVQ- SEWER LINE ' I ;' r*, •'` a _ j ' PIPES {MUST HAVE SCH 40 / SLEEVE WITHIN 10 OF ONE 2000—G ON, r / 0' -BACK O2RiGATION DITCH} SING LE—CO ARTMEN 50 FT OM LINED i� PRECAST 0NCRETE EPTIC �,` GRAVEL - ..-:' .. CH / FOLILOWED B ONE ; .�'' ,%' DRIVEWAY / RRlGATiON D TANK ;10100—G LON, - `,.�' ,{ D Y ,' 1 % /TWO ENT, '` LINER - ,' f: �} 0 ESP CLEAN UT P —AST C EF E IC ... TANK WIT AN EF FILTER 0 THE�OU ET.� PROPOSED' ;+ I -BEDROOM - SITE PLAN, LOCATION OF �-} S A CATION - ` +{ j PERCOLATION HOLE AND LO '' `; ' r. ` ,'' ,f 5/06/02 OF PROPOSED OWS FIGURE 2 it 71 PICAL PLAN VIEW - N.T.S. GRAVELLESS CHAMBER 3' BY 6.25' 4" SDR 35 PVC OBSERVATION/VENT PIPE 6' MIN. 3'--1 43.75 (TYPICAL CROSS-SECTION - N.T,S. 4" SDR 35 PVC OBSERVATION/VENT PIPE WITH CAP CK FI LL 15` INFILTRATORo CONTOUR- WEDGE 75' TOTAL - SIX TRENCHES 4" FVC SEWER PIPE (1 /8" PER FOOT DROP) FLOW SPLITTER BASIN FOR GRAVITY FLOW EFFLUENT T'OP' INLET LINE LINES TO ADDITIONAL TRENCHES FINAL FLOW SPLITTER BASIN SME VIEW 1 FIBERGLASS uQ W[TH STAINLESS STEEL BOLTS & URETHANE GASKET, 4' MAX I I I _ 1 `_�-- -� 1 w l . G j �FkB9ED PIC BASIN sto ' V e� • pVO DfSCHSROE PIPE LF^a LET avlNEzuoNr>aoti CqfYG� �NMIN. 1.5MIN ' 3HAMBER M=FLLaITDISC"GE ,ocGRAVELLES 3' BY 6.25' � � arunnnFr EXTENT OF EXCAVATION CALCULATIONS AND SPECIFICATIONS DESIGN CRITERIA RESIDENCE -- 5 BEDROOMS, <600C SF (1000 GALS) CDU — 1 BEDROOM, <700 SF (150 GALS) LOADING — 100/75 GAL/DAY/PERSON TOTAL LOADING — 1150 GPD PERCOLATION RATE = 39 MPI AREA = ((1.75 X 1150) X sqrt 39)/5 =2514 SF 50% REDUCTION FOR TRENCHES = 1257 SF JOB NO. 14720W TRENCH SPECIFICATIONS NUMBER OF TRENCHES — 5 LENGTH OF EACH TRENCH — 87.5 FEET, 14 CHAMBERS WIDTH OF EACH TRENCH — 3 FEET, 1 CHAMBER TOTAL NUMBER OF CHAMFERS — 84 CHAMBERS TOTAL AREA — 1302 SF DRAIN FIELD DETAILS 'SPEED LEVELER• TREATMENT UNIT SPECIFICATIONS TOTAL MINIMUM CAPACITY — 1.75 X q X (30 HOURS/24 HOURS) = 2516 GALLONS L"' RECOMMENDATION — ONE 2000—GALLON, SINGLE—COMPARTMENT, PRECAST CONCRETE SEPTIC TANK, FOLLOWED BY ONE 1000—GALLON TWO—COMPARTMENT SEP11C TANK WITH AN EFFLUENT FILTER ON THE OUTLET. 5/6/02 FIGURE 3 P -17A irvey Flat Loi RI /A,. Storwood — – ----- trnproverriont 565 N S�Orwc)c,d Survey A n. Co 8 1611 4 — plat 7-7-;-'_' t'117�, Lol R-1 /A. torWood C,vq t i"o 6111'.NA- 85 - R_o S c OLOrOOO �4-A 91 • lV "OkffA a .,w ;L tri �4 ik* "myfi 11V 0.1411" rA Loi RI /A,. Storwood — – ----- trnproverriont 565 N S�Orwc)c,d Survey A n. Co 8 1611 4 — plat 7-7-;-'_' t'117�, �4-A 91 • lV "OkffA a .,w ;L tri �4 ik* "myfi 11V 0.1411" rA 'k, k TS44, *I Ao' 2x cl T*j it k4# 0.0 X" Wd xW'*A tc yx*­A� Lx_ M 41 0,40% "Y'w 4.338' ,L $­ k r7 4: 1 Lj~42 &-*O*w 1. XV Z k."A t Z_ 'r f_'ktC'w' MA", W'M V'w wft"..f Vv*m l Ls wztjx#�� jmq1t*4 0 t A UZ!t"t N*AA6 rtf 'A IrKV'W V AJ A- A' L' CAP 'W -X4 6*" —C V4 44 m4f ir_ *W—" 0, ff —.VMS WJ U, 10. W" JWr -AAO0 P*14AV, "�e' 1od tl* 44 'wCq 1=0 *-rv-,T" rwV Loi RI /A,. Storwood — – ----- trnproverriont 565 N S�Orwc)c,d Survey A n. Co 8 1611 4 — plat 7-7-;-'_' t'117�, A F 895 EAF AM WRW ASPE" COLORADO 81611 TEL (1110) 225-4755 I"W: 03 Di -03 PERMIT fl4-O"I-O3 PROGRE55 04-14-03 G.D. SET C] BRICOL LOT - MA MAIN HOUSE 565 N. STAR 4000 DRIVE PITKIN COUNTY, CO. PROJECT EIRICOL LOT 11A MAIN HOUSE INT. REMODEL 2124DO 5021-A.9 DESCRIPTION�— EXISTING LOWER LEVEL FLOOR PLAN p AL9, 1!1° • P -O' SHHEEEV Qe NPl w.t l9f11 � �NOOR1tl ♦.t. \��\2` � � � \ m\� \� � /yƒ� � : � ?; :2 �\�� d � \\ \ \� � \ 1 MAIN LEVEL PLAN PROPOSED A2.1 SCALE: 1/4" - V-0" aiuQmu a 4 z PlA*rol;� 605 EAST MAIN STREET ASPEN, COLORADO 81611 TEL: (970) 925-4755 Issue: 02-20-2002 Final Starwood Approval 04-11-2002 Bid / Permit Set 05-08-2002 Bid / Constr. Set Q ASI 001 8.20.02 0 ASI 002 9.23.02 0 ASI 003 9.23.02 ,a ASI 005 10.25.02 0 ASI 008 10.28.02 CJ BRICOL — LOT 17A C.D.U. 565 N. STARWOOD DRIVE PITKIN COUNTY, CO. E SWIN 57e:i17 PROJECT BIR COL - LOT 17A CARETAKER DWELLING UNIT 2124.01 5.21-p.drg DESCRIPTION LOWER AND MAIN LEVEL FLOOR PLANS SCALE: 1/4" SHEET A2.1 o T S, M 16 Z. -I). WRITTEN "R.— .U A55p�y,RfS. V.C. BILL YALt RETAIN Ill CC