Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
pitkin.eh.246717401006 (2015)
oUNT� 4SITE WASTEWATER TREATI _NT SYSTEM (OWTS) CONSTRUCTION PERMIT 76 Service Center Rd. Aspen, CO - 81611 Phone: 970.920.5070 Fax: 970.920.5374 Permit #: 0014.2015.POWT Parcel ID #: 2467-174-01-006 Permit Issued: ]NEW ®REPAIR ❑REMODEL/ADDITION ❑TANK ONLY ®FIELD ONLY ❑AMENDMENT Owner(s): Dee and Kent Schuler Property Address: Legal Description: Size of Lot: .68 Size of Building: 417 Holland Hills Rd Lot 26 Holland Hills 1844 ft2 Acres Detached Accessory Unit: ❑YES ❑NO Sq. Ft. Size of Accessory This system is design for serve 3 bedrooms Designed By Phone #: Fax #: All Service Septic Project #: 970-704-0484 Mailing Address: Email Address: Perc Rate: .8 LATR Profile Hole Depth: 8' Minimum Tank Capacity: 1000 gallons C1142 Dated 33 Four Wheel Drive Road Sq. Ft. 4/28/15 Carla. OstbergCa)_gmail. com Depth to Groundwater or ➢ 8' Minimum Absorption 472 ft2 Permit Conditions: This OWTS Construction Permit is approved on the condition of compliance with the engineer design as submitted with the application and the specifications cited above. Changes must be approved by this Department and the engineer prior to construction. This system has failed and the field area needs to be replaced. The existing tank with RETROFAST unit will remain and flow to a new 18" external basin with effluent filter and then gravity flow to a level manifold to evenly distribute effluent to a gravelless chamber bed. The bed will be 5 "Quick -4" units wide by 8 long. Observation ports must be installed at each corner of the field. Field must be at least 10' from the property line. This Permit must be kept on-site during installation. The engineer must do a final inspection of the installation and submit an "as -built" letter to this Department within 30 days of the final inspection, unless a longer period of time has been agreed upon, in writing. This Department must also be called for the final inspection with a minimum of 48 hours notice. Minimum horizontal distances between components of the system and physical features shall conform to the requirements of the Pitkin County OWTS Regulation. This Permit is conditioned upon the property owner(s) providing for regular inspection, cleaning, and maintenance of the system by qualified personnel, in accordance with the manufacturer's recommendations and the requirements of the Pitkin County OWTS Regulation. Issuance of this OWTS Construction Permit does not constitute a guarantee, warranty, or representation by the Department that the system will operate properly or will not fail. Issuance of this permit does not imply compliance with Pitkin County building and/or land use regulations, nor guarantee issuance of building and/or land use permits. THIS PERMIT IS EXPRESSLY CONDITIONED UPON COMPLIANCE WITH ALL REQUIREMENTS OF THE PITKIN COUNTY OWTS REGULATION, INCLUDING BUT NOT LIMITED TO THOSE CONDITIONS SPECIFIED ABOVE. Plans and specifications for the proposed OWTS have been reviewed and are considered satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated in accordance with the Pitkin County OWTS Regulation. This Permit will expire 1 year from the date of issuance unless construction on the system has commenced. An "as -built" drawing must be submitted and approved by EH before final approval of the system will be issued. Issued By: Bryan Daugherty, REHS _ Date: 5/13/15_ Expires: 11/13/15 Installer:License #: Reactivation Authorized by: M Final Approval Issued By-,]jy/�t �f .� � Date: New Expiration Date: �p� =FMJ1 SITE WASTEWATER TREATM�; SYSTEM (OWTS) CONSTRUCTION PERMIT APPLICATION 76 Service Center Rd - Aspen, CO - 81611 Phone: 970.920.5070 Fax: 970.920.5374 Parcel ID# (available from the Pitkin County Assessor's Office_ 970-920-5160 or at www.aitkinassessor.org): l �/ _ O _ `7 Purpose of Permit: ❑ NEW REPAIR DUE TO FAILURE ❑ REMODEL/ADDITION F1 TANK ONLY El FIELD ONLY Cost of System Repair or Remodel/Addition (approximate): Address:/ Property Address:' , S I 14 �- i c, �� A •� 14. r r Block: Filing: I Subdivision: ,o 1 \ 1 Property Owner(s}�•�� Email Address: yv Owner's Mailing Addre�s:1 � c1 � ` A � » ; \ City, State, ZiL ' r Home Phone: �� / ) — Business Phone: G y -S 0 C11 U 5 - 'Contact information must be provided for 1he owner signing this application. Primary Contact Person/Applican (i of owner : Company: Contact/Applicant Mailing Addres : City, State, Zip: Cell Phone: Business Phone: Fax Number: Email Address: Building Permit # (if applicable): Lot Size (in acres): 7E7>1 _ 1 Size of Building (square feet): ` Number of Potential Bedrooms: Detached Accessory Unit? El YES NO Size of Accessory Unit (square feet): V Number of Potential Bedrooms In or Fixture List for the Accessory Unit: J` Water Source: ❑ PRIVATE WELL ❑ SURFACE WATER ❑ SPRING�yf,_OMMUNITY/PUBLIC WATER SYSTEM Name of Community/Public Water System (if applicable): Engineering Firm: Job Number: Phone Number- Fax Number: \5.��.Jk �2 L- 97U' - Mailing Address: State, C: PLEASE READ BEFORE SIGNING: I certify that the above information is complete and accurate and that I have provided complete and accurate information in all of the documents included in my application package. I acknowledge that EH/NR may revoke any permit i am issued if my application is found to contain any inaccurate, false, or misleading information. 1 understand that no construction may be undertaken on an OWTS until an OWTS Construction Permit is issued. OTer S*natur 7Requi�d Date: Applicant Signature: l Date: FOR OFFICE USE ONLY Received by EN/HR Staff: Fee & Receipt #: Date: ,. ,_'•,v1S March 8, 2008 NLv ., GS 0,.. _ Adr„..;, arms\OV- _.... _ _._.._.. _. _ 1 _,,;iion.As )P—Led: 10/7/08 001 LI . 2.0l -T. f O t.-) f 33 Four Wheel Drive Rd Carbondale, CO 81623 970-309-5259 June 6, 2015 Kent Schuler kent aspenfirst.com Onsite Wastewater Treatment System (OWTS) Installation Observations 417 Holland Hills Rd Pitkin County, Colorado OWTS Construction Permit Number 0014.2015.powt Kent, Project No. C1142 ALL SERVICE septic, LLC observed the installation of the onsite wastewater treatment system (OWTS) on May 28, 2015 for the subject property. Mountain Works installed the system. The existing 1000 -gallon, two-compartment septic tank with the BioMicrobics0 RetroFAST remained in use. An Orenco0 external filter basin was installed outside of the outlet side of the septic tank. This filter must be cleaned annually, or as needed. Effluent gravity flows to a gravelless chamber bed, connected with a level manifold, with five rows of 8 `Quick 4' InfiltratorO chambers for a total of 40 chambers and 480 square feet of infiltrative area. Inspection ports were installed on each corner of the bed. We recommend an annual maintenance contract for service of the BioMicrobics0 RetroFAST unit; however, no reductions in infiltrative area square footage or setback distances were provided with the use of this unit, making use of this technology not a requirement or condition of the OWTS Construction Permit. The OWTS was generally installed according to specifications. This observation is not a guarantee of workmanship and/or parts and materials. ALL SERVICE septic, LLC should be notified if changes are made to the OWTS in the future. Any additional OWTS construction must be according to the county regulations. LIMITS: Observations are limited to components that are visible at the time of the inspection. The installer must have documented and demonstrated knowledge of the requirements and regulations of the county in which they are working. The quality of the installation is dependent of the expertise of the installer, soil type, and weather conditions. Please call with questions. Sincerely, ALL SERVICE septic, LLC Carla Ostberg, MPH, REHS Reviewed s Richard H. �A New pipe from house to tank with clean out New inlet tee New sewer pipe coming into existing tank pipe entering external filter basin System was not functioning due to clogged and deteriorated cast iron piping �A New pipe from house to tank with clean out New inlet tee New sewer pipe coming into existing tank pipe entering external filter basin THE LOCATION OF EXISTING AND PROPOSED IMPROVEMENTS SHOWN ARE NOT THE RESULT OF A PROPERTY SURVEY. THE LOCATIONS ARE APPROXIMATE. IT IS THE HOMEOWNERS DUTY TO ENSURE ALL CONSTRUCTION AND IMPROVEMENTS LOCATIONS ARE ACCURATE. ALL SETBACK DISTANCES SHOULD BE CONFIRMED PRIOR TO EXCAVATION. I GARAGE DRIVEWAY INSPECTIOt EACH CORI` GPS COORDINATES: 2 N39-21.116'/ W107°00.824' © N39021.116'/ W107000.823' © N39-21.113'/ W107°00.819' D❑ N39-21.114'/ W107°00.817' E❑ N39021.116'/ W107000.820' E❑ N39021.116'/ W107000.820' DESIGN 2 -BEDROOM RESIDENCE + 1 FUTURE BEDROOM (75 GAL/PERSON/DAY x 2 PERSONS/BEDROOM x 3 BEDROOMS) WASTEWATER FLOW = 450 GALLONS TANK: 450 x 48 HOUR RETENTION TIME = MIN. 1000 GALLONS USE EXISTING 1000 -GALLON, TWO-COMPARTMENT TANK SOIL TREATMENT AREA (STA): LONG TERM ACCEPTANCE RATE (LTAR) = 0.8 GAL/ SQ FT CALCULATED STA = Q/LTAR = 450 / 0.8 = 562.5 SF GRAVITY, BED = 562.5 SF X 1.2 = 675 SF CHAMBERS = 675 SF X 0.7 = 472.5 SF / 12 SF / CHAMBER = 39 CHAMBERS FIVE ROWS OF 8 GRAVELLESS CHAMBERS TOTAL 40 'QUICK 4' CHAMBERS n RECORD DRAWING 1" = 20'-0" DOUBLE SWEEP CLEAN OUT EXISTING 1000 -GALLON, TWO-COMPARTMENT SEPTIC TANK WITH 'RetroFAST' 18" DIA EXTERNAL BASIN AND EFFLUENT FILTER RetroFAST BLOWER 'QUICK -4' CHAMBER BED. 5 ROWS OF 8 CHAMBERS = 40 CHAMBERS = 480 SF N 0' 10' 20' Scale: 1" = 20'-0" DRAWINGS MUST BE USED IN CONJUNCTION WITH DESIGN LETTER DATED 6/06/15 ALL 33 Four Wheel Drive Road Schuler Residence Date: 06/06/15 Carbondale, Colorado 81623 417 Holland Hills Road Phone 970.309.5259 Pitkin County, Colorado Designed By: CBO record gilpcarla@allserviceseptic.com Reviewed By: RHP Project Number: C1142 Drawn By: ANG Sheet 1 of 1 ALI 11111 April 28, 2014 33 Four Wheel Drive Rd Carbondale, CO 81623 910-309-5259 Kent Schuler 417 Holland Hills Road Basalt, CO 81621 kent@aspenfirst.com Subsurface Investigation and Onsite Wastewater Treatment System Design 2 -Bedroom Residence / 3 -Bedroom OWTS 417 Holland Hills Road Pitkin County, Colorado Kent, Project No. C1142 ALL SERVICE septic, LLC completed an onsite wastewater treatment system (OWTS) design for the subject residence. The property is located outside of Basalt, in an area where OWTSs are necessary. The legal description of the 0.68 -acre property is Lot 26, Holland Hills at Basalt, Tract: 55 Section: 17 Township: 8 Range: 86 Parcel of Land in Tract 55 Sec 17-8-86 BK 245 PG 198. SITE CONDITIONS A single-family residence presently exists. The existing OWTS, documented by Pitkin County Health Department Permit Number 76053 is experiencing problems. The pipe exiting the septic tank is clay and was extremely soft and almost entirely clogged. The status of the existing soil treatment area (STA) is not known; however, it is the desire of the homeowner to upgrade the STA at this time. Pitkin County OWTS Construction Permit 003.2012.pow2 documents the installation of a RetroFAST® added to the second compartment of the septic tank. The residence is served by a community water system. A ditch runs to the northeast of the property. This ditch is greater than 50 -feet from the proposed STA and has been lined. A gas line runs south of the area of the proposed STA. This line will need to be located and the STA placed in an area that will not interfere with this gas line. Source Gas must be contacted prior to work commencing on the STA. The area of the proposed STA slopes slightly to the southwest toward the Roaring Fork River and is located in an irrigated area of the yard. aMSV�,�y' aA}� } 7: Clay inlet pipe Page 2 Pipe exiting side of septic tank / clay / very soft and clogged SUBSURFACE Soils in Holland Hills have consistently been classified as Loamy Sand with percolation rates ranging from 10 to 30 minutes per inch (MPI). Permit 76053 documents the percolation rate (performed 8/16/76) at 15 MPI with a soil classification of "Red Sandy Loam and some Clay". At that time, no groundwater or bedrock was encountered within 8 -feet of grade. An 8 -foot deep profile pit must be excavated prior to installation of the STA to verify soil type. This office and Pitkin County Environmental Health Department must be contacted upon digging the test pit. A long term acceptance rate (LTAR) of 0.8 gallons per square foot will be used to design the OWTS, in accordance with Pitkin County OWTS Regulation, Table 6.28-7. DESIGN SPECIFICATIONS The OWTS design is based on 3 -bedrooms. A design flow of 450 GPD will be used. Design Calculations: 3 bedrooms x 75 gallons/person/day x 2 people/bedroom = 450 gallons/day Septic Tank Capacity = 450 gallons/day x 48 hour retention time = 900 gallons minimum STA Calculations = 450 gallons/day / 0.80 SF/gallon (Loamy Sand Type 1) = 565.5 SF 565.5 SF x 1.2 (gravity bed) x 0.7 (chambers) = 472.5 SF 472.5 SF / 12 SF/chamber = minimum 39 'Quick 4' Infiltrator® chambers We recommend exploring the sewer pipe from the house to the septic tank to assure that line is in good condition. If found to be in disrepair, this line should be replaced and a double sweep clean out installed within 5 -feet of the house, if one does not already exist. The clay inlet pipe should be replaced with PVC pipe. The existing septic tank will continue to be utilized. The BioMicrobics® RetroFAST may remain in the septic tank, if desired by the owner. An Orenco® external filter basin should be installed outside of the outlet side of the septic tank. Effluent will gravity flow to a gravelless chamber bed, connected with a level manifold, with five rows of 8 'Quick 4' Infiltrator® chambers for a total of 40 chambers and 480 square feet of infiltrative area. Inspection ports must be installed on each corner of the bed, and ports may be cut to grade and placed in a sprinkler box. Over -excavation of the existing STA will be necessary due to the location of the gas line. If materials encountered in the existing STA are saturated, they must be staged and dried before disposal at the landfill. If the existing STA material is found to be dry, it can remain and excavation of the new bed can Page 3 continue. Soil replacement may be necessary if the extent of the excavation is greater than 4 -feet. Onsite (sandy loam) soils or ASTM C33 concrete sand may be used as soil replacement. If other soils are imported, this office must be contacted for review and approval of the soil. The component manufacturers are typical of applications used by contractors and engineers in this area. Alternatives may be considered or recommended by contacting our office. Construction must be according to Pitkin County Onsite Wastewater Treatment System Regulations, the OWTS Construction Permit provided by Pitkin County Environmental Health Department, and this design. REVEGETATION REQUIREMENTS An adequate layer of good quality topsoil capable of supporting revegetation shall be placed over the entire disturbed area of the OWTS installation. A mixture of native grass seed that has good soil stabilizing characteristics (but without taproots), provides a maximum transpiration rate, and competes well with successional species. No trees or shrubs, or any vegetation requiring regular irritation shall be placed over the STA. Until vegetation is reestablished, erosion and sediment control measures shall be implemented and maintained on site. The owner of the OWTS shall be responsible for maintaining proper vegetation cover. OPERATION INFORMATION AND MAINTENANCE The property owner shall be responsible for the operation and maintenance of each OWTS servicing the property. The property owner is responsible for maintaining service contracts for manufactured units, alternating STAs, and any other components needing maintenance. Geo -fabrics or plastics should not be used over the STA. No heavy equipment, machinery, or materials should be placed on backfilled STA. Livestock should not graze on the STA. Plumbing fixtures should be checked to ensure that no additional water is being discharged to OWTS. For example, a running toilet or leaky faucet can discharge hundreds of gallons of water a day and harm a STA. The homeowner should pump the septic tank every two years, or as needed gauged by measurement of solids in the tank. Garbage disposal use should be minimized, and non -biodegradable materials should not be placed into the OWTS. Grease should not be placed in household drains. Loading from a water softener should not be discharged into the OWTS. No hazardous wastes should be directed into the OWTS. Mechanical room drains should not discharge into the OWTS. The OWTS is engineered for domestic waste only. ADDITIONAL CONSTRUCTION NOTES If design includes a pump, air release valves and weep holes must be installed to allow pump lines to drain to minimize risk of freezing. The pump shall have an audible and visual alarm notification in the event of excessively high water conditions and shall be connected to a control breaker separate from the high water alarm breaker and from any other control system circuits. The pump system shall have a switch so the pump can be manually operated. Excavation equipment must not drive in excavation of the STA due to the potential to compact soil. Extensions should be placed on all septic tank components to allow access to them from existing grade. Backfill over the STA must be uniform and granular with no material greater than minus 3 -inch. Page 4 INSTALLATION OBSERVATIONS ALL SERVICE septic, LLC must view the OWTS during construction. The OWTS observation should be performed before backfill, after placement of OWTS components. Septic tanks, distribution devices, pumps, dosing siphons, and other plumbing, as applicable, must also be observed. ALL SERVICE septic, LLC should be notified 48 hours in advance to observe the installation. LIMITS: The design is based on information submitted. If soil conditions encountered are different from conditions described in report, ALL SERVICE septic, LLC should be notified. All OWTS construction must be according to the county regulations. Requirements not specified in this report must follow applicable county regulations. The installer should have documented and demonstrated knowledge of the requirements and regulations of the county in which they are working. Please call with questions. Sincerely, ALL SERVICE septic, LLC Carla Ostberg, MPH, REHS Reviewed By: Richard H. Petz, Liability Clause: Under no circumstances whatsoever shall the liability of ALL SERVICE septic, LLC, in connection with any contract, directly or indirectly, exceed the total amount paid by the client to ALL SERVICE septic, LLC for the services and/or goods which are the subject of the contract in connection with which the liability arises. I o z a� z ¢ J M LL 00 J �- J ZW wZ) ZWW I 3�.a WO J M c -i CL,O C) Z LL cn z owe Z d J 0 ¢ cn �LL O0 CL W OW- C)° W= CLU Cl) ¢ Z W I Re& 0 w V) 0 0- 0 W H I U (D -°O v p Co N o '0 to o = U E o U Z �ti Y L) Ova CL M N O 0 c U O l -U N N 0 0 LO U N U O ? M N a O to i-0 0 N O p N LL -0 p (_L6 M -C (B M U a. U U pZ=�ZzdU) U LLJ 3com((nIt W U)N �Q x W w Of W u 0 a uzUW HLL W O- CL u p of p �<mw Q U) v Mw WO Cti z J p I Z p J J p Q O U) Q W w Q w p W Z Q p W �(n-2 d J m Of w m Q U 0 LO J_ Q H O 0- z O d U) z U @ -0 �o CU N o (j -0 w O = U L E Z oU .� Y U L Cl) N E 0 o o, N Lo N N 0 O LO N O a; 0 N U p i-- 00 ou�oi m 00 M M= N MUO.. 0 ❑ W w CL ¢ _ pW -0- w z o W -i w LL U �O �z oow o > 00( V-O w w w >p p 0w o a9¢ gJ � U)w O � > Ly m U? d J w> g~>O J -'0W i >¢¢ Uz U > zQ w p O J u_Q p (f)co w av a e cn F- O W �ZLL W cn� cai�m Z I •- I I I_ U m Q a_ w ~ p O W �a U Uw U p >J Lo c? Z ZQ <O- � �O 0 w (L 0? U) www Z 00 U Qw QW UOO=< dZ p(n p J aw =~a (n � ? "vu BMX wE-❑ O¢O 0 M M 0 D Z D 0 W LO J_ Q H O 0- z O d U) z U @ -0 �o CU N o (j -0 w O = U L E Z oU .� Y U L Cl) N E 0 o o, N Lo N N 0 O LO N O a; 0 N U p i-- 00 ou�oi m 00 M M= N MUO.. 0 18 -in. External Effluent Filter Basin Applications Orenco's 18 -in. (457 -mm) External Effluent Filter Basin, featuring patented' Biotube® filter technology, is an ideal way to improve performance of existing residential septic systems by reducing solids discharge to the drainfield. External Filter Basins eliminate the need to make costly, and sometimes hazardous, modifications to existing septic tanks with restrictive access openings or to unusable outlet baffles or tees. Orenco's External Effluent Filter Basins are the best solution for retrofitting existing residential septic systems. The 8 -in. (203 -mm) diameter Biotube Filter has almost 5 ft' (0.5 trF) of filter area, to resist clogging while providing maximum long-term protection. Covered by U.S. patent numbers 5,492,635 and 4,439,323 To Order Call your nearest Orenco Systems®, Inc. Distributor. For nearest Distributor, call Orenco at 800-348-9843, or visit www.orenco.com and click on "Where to Buy." Standard Features & Benefits Complete packaged kit ready to install; reduces cost and simplifies installation Removes approximately two-thirds of suspended solids, on average Flow control discharge orifices limit the flow rate leaving the basin Extendible cartridge handle simplifies filter inspection Basin can be extended to match depth of exist- ing tank outlet Large filter area resists clogging and increases cleaning intervals Easy to clean by simply hosing off filter car- tridges Corrosion -proof con- struction ensures long life 1/8th-inch diameter holes reduce suspended solids by an average of 67% Biotube Filtering, Process Effluent from the rela- Effluent then enters the tively clear zone of the annular space between septic tank, between the housing and the the scum and sludge Biotubes, utilizing the layers, exits the tank entire surface for filter - via the tank's outlet ing. Particles larger assembly and enters than the mesh of the Biotube Effluent the Biotube are Filter through inlet holes prevented from in the filter housing. leaving the tank. Orenco® Orenco Systems®, Incorporated APS -1`1`13-1 Orenco Systems® Inc., 814 Airway Ave., Sutherlin, OR 97479 USA Rev. 1.6 ®11/13 800-348-9843 • 541-459-4449 • www.orenco.com Page 1 Model Codes for Ordering 18 -in. External Effluent Filter Basin FTB 18 24 08 12 Tilter cartridge height: 12" (305 mm) standard Filter diameter: 8" (203 mm) standard Basin height: 24" (610 mm) standard Basin diameter: 18" (457 mm) standard Biotube effluent filter basin Distributed By: Effluent Filter Basin with Extension to Grade Grade ring Insert (included with 24-inc basin; Vault Lid (ordered separately) Riser (ordered separately) Handle assembly (extensions not included) Influent holes Biotube" filter cartridge APS-FTB-1 Orenco Systems® Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA Rev. 1.6 ® 11/13 800-348-9843 • 541-459-4449 • www.orenco.com Page 2 PITION COUNTY HEALTH DEPARTMENT 76053 _ PERMIT NUMBER ___ RECEIPTNUMBER Phone No. Owner a Owner's Mailing Address Contractor < < 1-- Phone No Address System's Contractor's Name Address 4 J_// -117 l ` l Legal Description < Lot Size _ • � •� is \� :f_ �. Type 9 Y _.._ T e of Building b Use- Number of Bedrooms L- _�� n__ Type of Water Supply Owner's Signature - r - `� - --- Date PLOT PLAN: ATTACHED AS REQUIRED -0F#########•�#####d4################X•######ih################-%#######-###iE####•X•####K#'F#W#•+'F####iF Type of Individual Sewage Disposal System s_ fie, y Type of Soil or Soil Classification Proximal Location of Bedrock efz-6 CV Proximal Location of Ground Water Table -Ale) r Dc--- 'M IUCD -`S� / # # # # # # iF # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # if # # # # # # # # # # # # -Y. # # # # # # # # # # # # # # # # # # # # # �(# it # �# ' # # # •K 'k # % # Percolation Test Date ._ ��_ �� Minutes Per Inch 7d' Minimum Recommended Absorption System Size t �j Minimum Recommended Tank Size 7U 1�L L Special Conditions of Issue: NOTICE When properly signed for issuance, this application B�t/f'•��1-11-4 fJ ) IAI 11 AJ becomes your permit. Application valid One year from date. If an individual sowafle disposal permit is issued (-/ / / �� �LZ7�� X 11 �� for property di which no building permit has been IOWA /�C/ /�� � 1� / , ) issued, the individual sewage disposal pormit shall /i- •/ G /, expire 120 days after its issuance it construction has _ not been commenced. Any change in plans or speci- �� d fications after the permit has been issued invalidates the permit, unless approval is secured from the Hoalth Officer for such than os. 7Z Y6 -�Date rG'C 'L� �la_ .. Approved for Issuance By _ ####x####+�##•F##K##a�##+r#####�:•*##//##x###### x### �##;;,'�-zx-tea:#-z#x##x# -.�a:-#�##a: �--##.v.xxF;�######### FINAL INSPECTION APPROVAL/- r:F"'� Date CTI O (Drawing of System on Back) r.)gl Vr sr GA c.tripJ o j..- f EH,'NR Permit #: 003.2012.pow2 ONSITE WASTEWATER TREATMENT SYSTEM (OWTS) CONSTRUCTION PERMIT 76 Service Center Rd Aspen. CO - 81611 Phone: 970-920.5070 Fax: 970.920.5374 Parcel ID #: 2467-174-01-006 Permit Issued; []NEW ❑REPAIR ❑REMODEL%ADDITION []TANK ONLY []FIELD ONLY EIAMENDMENT Owner(s): Kent Schuler ^ — Property Address: 417 Holland Hills Road Legal Description: Lot 26. Holland Hills Size of Lot: Acres Detached Accessory Unit: Size of Building: Sq. Ft. Size of Accessory Unit: The system is designed for: 2 bedrooms (Amendment to Permit 76053; Designed By: All Service Septic. LLC Phone #: Fax #: Project #: _ Mailing Address: Email Address: ❑YES ❑NO Dated: Perc Rate: 15 mpi (existing) Profile Hole Depth: Depth to Groundwater or Bedrock: Minimum Tank Capacity: existing _ _ _ Minimum Absorption Area: existing Sq. Ft. Permit Conditions: This 04VTS Construction Permit is approved on the condition of compliance :vith the engineer design as submitted ,441111 the application and the specifications cited above. Changes must be approved by this Department and the engineer prior to construction. This permit is issued as an amendment to an existing permit 76053- The existing system consists of a 1000 gallon, two- compartment concrete Copeland septic tank and a 12'x39' pipe and gravel absorption area. A RetroFAST will be added to the second compartment of the existing tank. This Permit must be kept on-site during installation. The engineer must do a final inspection of the installation and submit an "as -built" letter to this Department :within 30 days of the final inspection. unless a longer period of time has been agreed upon. in writing. This Department must also be called for the final inspection %ti,qth a minimum of 48 hours notice. Minimum horizontal distances between components of the system and physical features shall conform to the requirements of the Pitkin County OWiS Regulation. This Permit is conditioned upon the property owner(s) providing for regular inspection. cleaning. and maintenance of the system by qualified personnel- in accordance with the manufacturer's recommendations and the requirements of the Pitkin County 01111T Regulation_ Issuance of this ObVTS Construction Permit does not constitute a guarantee, warranty. or representation by the Department that the system will operate properly or will not fail. THIS PERMIT IS EXPRESSLY CONDITIONED UPON COMPLIANCE WITH ALL REQUIREMENTS OF THE PITKIN COUNTY OWTS REGULATION, INCLUDING BUT NOT LIMITED TO THOSE CONDITIONS SPECIFIED ABOVE. Plans and specifications for the proposed OWTS have been reviewed and are considered satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated in accordance with the Pitkin County OWTS Regulation. This Permit will expire 1 year from the date of issuance unless construction on the system has commenced. An "as -built" drawing must be submitted and approved by EH before final approval of the system will be issued. Issued By: �„t I �� ! > �2 t ` Date: Expires: . _' / Installer: License: Reactivation Authorized by: Final Approval Issued By. Date: New Expiration Date: p& earthtees' 200 80