pitkin.eh.246721400009 (2016)
COUNT ONSITE WASTEWATER TREATMENT SYSTEM (OWTS) CONSTRUCTION PERMIT 76 Service Center Rd- Aspen, CO - 81611 Phone: 970.920.5070 Fax: 970.920.5374 Permit #: 0019.2016.POWT Parcel ID #: 2467-214-00-009 Permit Issued: ❑NEW ®REPAIR ❑REMODEL/ADDITION ®TANK ONLY ❑FIELD ONLY ❑AMENDMENT Owner(s): Property Address: 26150 Highway 82 RPd Tail LLC Legal Description: Size of Lot: 132 Acres Detached Accessory Unit: ❑YES ONO Size of Building: ft2 Sq. Ft. Size of Accessory This system was originally designed to serve the barn (permit #78044) Designed By Phone #: Fax #: Perc Rate: All Service Septic, LLC 970-309-5259 Project #: Mailing Address: Email Address: Profile Hole Depth: Minimum Tank Capacity: 1000 gallons C1219 Dated 33 Four Wheel Drive Road Sq. Ft. 6/16/16 Carla. Ostberg(d�gmail.com Depth to Groundwater or Minimum Absorption 300 ft2 existing Permit Conditions: This OWTS Construction Permit is approved on the condition of compliance with the engineer design as submitted with the application and the specifications cited above. Changes must be approved by this Department and the engineer prior to construction. This permit is to replace the damaged existing 1000 gallon tank with a new 2 compartment, 1000 gallon concrete tank. Risers must be accessible from grade and an effluent filter must be installed in the outlet of the tank. The new tank location must be at least 5' from the barn. The new tank will gravity flow effluent to the existing field area. This Permit must be kept on-site during installation. The engineer must do a final inspection of the installation and submit an "as -built" letter to this Department within 30 days of the final inspection, unless a longer period of time has been agreed upon, in writing. This Department must also be called for the final inspection with a minimum of 48 hours notice. Minimum horizontal distances between components of the system and physical features shall conform to the requirements of the Pitkin County OWTS Regulation. This Permit is conditioned upon the property owner(s) providing for regular inspection, cleaning, and maintenance of the system by qualified personnel, in accordance with the manufacturer's recommendations and the requirements of the Pitkin County OWTS Regulation. Issuance of this OWTS Construction Permit does not constitute a guarantee, warranty, or representation by the Department that the system will operate properly or will not fail. Issuance of this permit does not imply compliance with Pitkin County building and/or land use regulations, nor guarantee issuance of building and/or land use permits. THIS PERMIT IS EXPRESSLY CONDITIONED UPON COMPLIANCE WITH ALL REQUIREMENTS OF THE PITKIN COUNTY OWTS REGULATION, INCLUDING BUT NOT LIMITED TO THOSE CONDITIONS SPECIFIED ABOVE. Plans and specifications for the proposed OWTS have been reviewed and are considered satisfactory. Permission Is hereby given to the property owner(s) to perform the work indicated in accordance with the Pitkin County OWTS Regulation. This Permit will expire 1 year from the date of issuance unless construction on the system has commenced. An "as -built" drawing must be submitted and approved by EH before final approval of the system will be issued. Issued By: Bryan Daugherty, REHS Date: 6/21/16 Expires: 10/21/16 Installer:, License #: Reactivation Authorized by: V Final Approval ssued By: Date: / �� n �� New Expiration Date: EJ Fee Ill ONSITE WASTEWATER TFMATMENT SYSTEM tom)CONSTRUCTION PERT'APPLICATIONE /NR 76 Service center Rd - Aspen, 00 - 81611 H Phone: 970.920.5070 Fax: 970.920.5374 Parcel 10# (available from the Pitkin County Assessor's Office00`1 L-A (-A 970-920-5160 or et www- tkinasse or.ora): H Purpose of Permit: NEW REPAIR DUE TO FAILURE ❑ REMODELIADDITION F]TANK ONLY ❑ FI" ONLY Cost of System Repair 6r F;;odellAddition (approximate): Cell Phone:,Business lc)�I-qs Property Address: L-r Fax Number Lot Block: Filing: Su6divisiGn: Property Owner(s)*. Email Address: U1 C— Owner's Mailing Address: City, State, Zip: 2 ocD ')o Home Phone: Business Phone: znmrmarmn mlr r 1>P nmvfr rut U - primary Contact person/Applicant (if not o r)- Company; H ContactlApplicant Mailing Address'. City.State. zip17h . Cell Phone:,Business lc)�I-qs Phone: L-r Fax Number Email Address-* Permit # Lot Size (in acres): - Number of Potential Bedrooms: of Building (square feet): ZI Size Of Accessory Unit (square feet): Detached Accessory Unit', YES F NO Number of Potential BeCIROMS In or Fixture List for the Accessory Unit, Water Source:COMMUNrTY/PuBuc WATER sysTEm U4rKVATE WELL El SURFACE WATER ❑ SPRING ❑ Name of Community/public Water System (if applicable): Engineering Firm: Job NUMDer. State, Zip: Phone Number. Fax Number ?LEASE READ BEFORE SIGNING' sucrate Irtfonrotion In all of the documents certify dug the above information is complete and accurate and that I have Provided complete and a Included in my application package. I acknowledge that EHMIR MY MVQk6 WIV Permit I — issued ff my aPPilicabon IS found to contain any inaccurate, false, or misleading information. I understand that no construction way be undertaken on an OW173 until an OWTS Construction Permit is issued. Owner Signature (Requirt Date: Applicant Signature: Date: (0 I L(O FOR FOR OFFICE USE ONLY Received by EbYHR Stafr: Fee & Receipt* Date: 7 - r —%—trl C I —1wali.n-nk Updated: 10771U -1-AQ%V: >- -Aar" c- -w—r- CBO Inc. 33 Four Wheel Drive Road Carbondale, CO 81623 cell) 970-309-5259 office) 970-704-0484 L" carla.ostberg@gmail.com June 27, 2016 Travis Hughes Travishughes501 reagan.com Installation Observations 26150 Hwy 82 Pitkin County, Colorado OWTS Construction Permit 0019.2016.POWT Travis, Project No. C1219 CBO Inc. observed the installation of the septic tank on June 27, 2016 for the subject property. Hughes Excavation installed the tank. The installation included a new 1250 -gallon, two-compartment Valley Precast concrete septic tank with an Orenco® Biotube Effluent Filter on the outlet tee. A new clean out was installed between the barn and septic tank, and the outlet line from the septic tank was connected to the existing sewer line leading to the existing soil treatment area (STA). The septic tank was generally installed according to specifications. This observation is not a guarantee of workmanship and/or parts and materials. CBO Inc. should be notified if changes are made to the onsite wastewater treatment system (OWTS) in the future. Any additional OWTS construction must be according to the county regulations. LIMITS: Observations are limited to components that are visible at the time of the inspection. The installer must have documented and demonstrated knowledge of the requirements and regulations of the county in which they are working. The quality of the installation is dependent of the expertise of the installer, soil type, and weather conditions. Please call with questions. Sincerely, CBO Inc. ('G (a hJ ; Carla Ostberg, MPH, REHS Page 2 Clean out View of septic tank Inlet tee Outlet tee ONSITE WASTEWATER TREATMENT SYSTEM (OWTS) CONSTRUCTION PERMIT 76 Service Center Rd - Aspen, CO • 81611 Phone: 970.920.5070 Fax: 970.920.5374 Permit #: 0019.2016.POWT Parcel ID #: 2467-214-00-009 Permit Issued: ❑NEW ®REPAIR ❑REMODEL/ADDITION ®TANK ONLY ❑FIELD ONLY ❑AMENDMENT Owner(s): Red Tail. LLC Property Address: Legal Description: Size of Lot: 132 26150 Hiahwav 82 Acres Detached Accessory Unit: ❑YES ®NO Size of Building: ft2 Sq. Ft. Size of Accessory This system was originally designed to serve the barn (permit #78044) Designed By: All Service Septic, LLC Phone #: 970-309-5259 Fax #: Perc Rate: Minimum Tank Capacity: 1000 Project #: Mailing Address: Email Address: Profile Hole Depth: 3Ilons Sq. Ft. C1219 Dated: 6/16/16 33 Four Wheel Drive Road Carla. Ostberg(a-)gmail. com Depth to Groundwater or Minimum Absorption 300 ft2 existing Permit Conditions: This OWTS Construction Permit is approved on the condition of compliance with the engineer design as submitted with the application and the specifications cited above. Changes must be approved by this Department and the engineer prior to construction. This permit is to replace the damaged existing 1000 gallon tank with a new 2 compartment, 1000 gallon concrete tank. Risers must be accessible from grade and an effluent filter must be installed in the outlet of the tank. The new tank location must be at least 5' from the barn. The new tank will gravity flow effluent to the existing field area. This Permit must be kept on-site during installation. The engineer must do a final inspection of the installation and submit an "as -built" letter to this Department within 30 days of the final inspection, unless a longer period of time has been agreed upon, in writing. This Department must also be called for the final inspection with a minimum of 48 hours notice. Minimum horizontal distances between components of the system and physical features shall conform to the requirements of the Pitkin County OWTS Regulation. This Permit is conditioned upon the property owner(s) providing for regular inspection, cleaning, and maintenance of the system by qualified personnel, in accordance with the manufacturer's recommendations and the requirements of the Pitkin County OWTS Regulation. Issuance of this OWTS Construction Permit does not constitute a guarantee, warranty, or representation by the Department that the system will operate properly or will not fail. Issuance of this permit does not imply compliance with Pitkin County building and/or land use regulations, nor guarantee issuance of building and/or land use permits. THIS PERMIT IS EXPRESSLY CONDITIONED UPON COMPLIANCE WITH ALL REQUIREMENTS OF THE PITKIN COUNTY OWTS REGULATION, INCLUDING BUT NOT LIMITED TO THOSE CONDITIONS SPECIFIED ABOVE. Plans and specifications for the proposed OWTS have been reviewed and are considered satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated in accordance with the Pitkin County OWTS Regulation. This Permit will expire 1 year from the date of issuance unless construction on the system has commenced. An "as -built" drawing must be submitted and approved by EH before final approval of the system will be issued. Issued By: Bryan Daugherty, REHS Date: 6/21/16 Expires: 10/21/16 Installer: License #: Reactivation Authorized by: Final Approval Issued By: Date: New Expiration Date: ❑ Fine Paw r /\\ � t /,! ,� �� '� �j I'ITKIN COUNTY HEALTH DEPARTMENIT 16 , PERMIT NUMBER � �_b CC� `�--- RECEIPT NUMBI Phone NO. Harry H. Baumann Phone - 2300 Owner -_ __ �__ _•_ -- - ___. Owner's Mailing Address ContractorAddress, - -� P.O. Box 5036, Snowmas System's Contractor's Name -. Address (See Reverse) Legal Description ^.-.----- Lot Size _ 140 acres _ Ty; Number of Bedrooms Offich & 1 bathroom i. it Harry H. Baumann (by C.A.) Owner's Signature - ---------- Village, CO 81615 Phone No. of Buildino I ;i Use - Barn well ni V/:::I!rr Supply 7 June 1978 Date — __...- PLOT PLAN: ATTACHED AS REQUIRED I t i:k'iF##-}iL4A;,i '.F •ii?}.Y +':r •.; }g'3 :::: :: +-2 .; :: R'k X' -F.-._._... ifa Riitii#iiiki 5271 i}3ki'k-)t%#-'�%i�-h�!F '=4--33:-:E .. .. .. Type of Individual Sewage Di linsal System -�- Y � Type of Soil or Soil Classifical; " Proximal Location of Bedrock 0 Proximal Location of Ground'Naier Table' a! ;k K i . » kk k ;} # * # # i 2 : e i # ;E i dE 3 2 % X- Y. S iF .: :: £ i i i i i # # i # i Y i i i i i } # f XYi!-) !k -� it Y '.E 4 i lk 2 #s -k :k 4- ik i5 '4 s ". c ..: S i i'.:k '. t 'k : i i; :k GR C�k R -.• Percolation Test Date .-. -- �-- Minimum Recomnionded Abscrution System Size Minimum Recommended Tank Size Special Conditions of Issue: AZ_ U Minutes Per Inch NOTICE When pro �orly siunod for issuance, thia aPPlieation becomes your permit. Application valid one year from data. If or individual sowage disposal parmit 1s issued for propel ty an which no building permit has been issued, Eh) individual sawoga disposal parmit s11811 oxplro 120 days after its issuance it construction ha, not boon ontmonced. Any chonpo in plans or speci- fications after the parmit has hoof' issued Invalidates the permit, unless approval is secured from tho Haalth Officer for �uuch Ghon as/�/Z . / /wz -__-Date Approved for Issuance ny /21 Zf �' ate FINAL INSPECTION APPROVAL -- (Drawing of System on Back) �f•>fir.-ik�k�rir�i>r:-ki#;:-;.•-z��;rtf�c•:s:t�.-s,-;:x� Inspection Date: Inspector's Name: Business Name: Phone Number Email: Pitkin County Systems QUESTIONS FOR PROPERV OWNER PRIOR TO INSPECTION: Is the home currently occupied? YES If NO, how long has the hor',ne been vacant? How many bedrooms are in the home? If secondary treatment is u�ed, who is the maintenance provider? Were system records availE If YES: Permit number: Date of Final AE # of bedrooms 1 e from Pitkin County? " .f c� V\xk WeJ I b Q Was an as-built�tlrawing available? YES NO Is the as -built d awing accurate? YFS NO .If NO: Complete a drawing of the system on last page of this form as accurctely as possible. Any question marked -,FAIL will require correction before an OWTS Use permit is issued. SITE CONDITIONS: ti -A4 c st Inlet tee repair — picture taken by R. Kanan 2/13/13 Outlet tee repair — picture taken by R. Kanan 2/13/13 Looking northwest, toward approximate area of absorption field. Tank located in area of shovel. Tank damage Condition of tank at 11:30am 2/13/13. Repairs not yet complete. Tank lid and corner repair — picture taken by R. Kanan 2/13/13 View of inlet side of tank — no tee 2/7/13 View of outlet side of tank — no tee 2/7/13 Looking southwest, approximately in the area of the absorption field area and toward the tank. Please call with questions. Sincerely, Nvt (�-' Osf&Ats Carla Ostberg, MPH, REHS NAWT Certified Inspector Certification # ITC 11042010 Exp. 2014 Tank lids uncovered, looking southwest toward barn. Note top of tank lid and side of tank damaged during excavation. 2/7/13 CBO Inc. y'4 33 Four Wheel Drive Road Carbondale, CO 81623 cell) 970-309-5259 office) 970-704-0484 p4�,n ufn cbo2610@yahoo.com February 13, 2013 Ron Kanan rkanan(c aol.com Onsite Wastewater Treatment System (OWTS) Use Permit Inspection 26150 Hwy 82 (barn) Pitkin County, Colorado Mr. Kanan, As requested, CBO Inc. performed an Onsite Wastewater Treatment System (OWTS) Use Permit inspection at 26150 Hwy 82, Snowmass, CO on February 7 and 13, 2013. The subject OWTS consists of one 1000 -gallon two-compartment septic tank. The absorption area consists of 300 square feet of pipe and gravel, according to Pitkin County records. There was a significant amount of snow cover present at the time of the inspection. The permit and as -built drawing were provided by Pitkin County Environmental Health Department. (Parcel ID # 2467-214-00-009) The septic tank appeared to be in good condition; however, in uncovering the tank with the backhoe, the tank lid and corner were damaged. The damage was above the water line and should not impact the functioning of the septic tank. Neither the inlet or outlet tee was in place at the time of the first inspection. A second visit to the site was performed around 11:30am on February 13, 2013 and the repairs had not yet been completed. Pictures verifying repairs were emailed to CBO Inc. around 1:30pm on February 13, 2013. It appears the tank was repaired and tees were installed, as necessary to pass the inspection. The absorption area showed no signs of saturation, and had no indication of failure. Observation ports were not observed. This evaluation is not a guarantee of future system performance. This inspection is good for one year. I would be happy to return to the site to verify the repairs in person, if requested. It is important to note that this system was permitted and approved to serve a bathroom and office in the barn. m ±A Copy s qy i� Approximate area of OWTS components 26150 Hwy 82, Snowmass, CO Nomenclatures 4 -in. Biotube Filter (standard) FT0400-0] [] Options: Blank =no options M = flow modulation plate installed A = float bracket attached Cartridge height: 28" and 36" are standard Housing height: 36" and 44" are standard Filter diameter (inches) W = fits Type 3034 outlet pipe S = fits Schedule 40 outlet pipe Blank = 1/8" filtration P = 1/16" filtration Biotube effluent filter series 8 -In. Blotube Filter (base inlet model) FT [1 08 22 -14 BF—] Options: A = float bracket FS = 2" outlet orifice FSO = 2" outlet orifice and overflow plate` Base inlet model Cartridge height: 14" standard Housing height: 22" standard Finer diameter (inches) 08 = 8" Blank = 1/8" filtration P = 1/16" filtration Biotube effluent fitter series . Also available with coupling and sleeve as a "kit': FT-OVERFLOWKfr 4 -in. Biotube Jr. (includes cartridge and housing) FT J 0 0 04 18]x]_ 1 Options: Blank = no options M = flow modulation plate installed A = float bracket attached Cartridge height (inches) Filter diameter (inches) W = fits Type 3034 outlet tee S = fits Schedule 40 outlet tee Blank = 1/8" filtration P = 1/16" filtration I Junior series Biotube effluent filter series 4 -in. Biotube Filter Insert (cartridge only) FT i 0 04 18 - P - ]_] For customized options (e.g., NC indicates North Carolina regions) tw = fits Type 3034 outlet tee S = fits Schedule 40 outlet tee Cartridge height (inches) Filter diameter (inches) Blank = 1/8" filtration P = 1 /16" filtration I Insert Biotube effluent fitter series 4-1n. Biotube 4-1n. Biotube Jr. Effluent Filter Bible ss Ste op se Air v 3e° fi Solid Filter I Distributed By: Residential Biotube' Effluent Filters Applications Our patented* 4 -in. (100 -mm) Biotube Effluent Filters, Biotube Jr., Biotube Insert Filters, and Biotube Base Inlet Filters are ideal for residential septic tanks and have a lifetime warranty. They prevent large solids from leaving the tank, dramatically improving wastewater quality and extending the life of residential drainfields. 4 -in. (100 -mm) Biotube Effluent Filter Orenco's superior effluent filters resist clogging better than all other brands. Our stan- dard, full-sized 4 -in. (100 -mm) Biotube Effluent Filter provides maximum long-term protection in a complete package, with housing. Our 4 -in. (100 -mm) Biotube Jr., at half the size of our standard model, has more filtering capacity than the full-sized filters sold by other manufacturers. For tanks with existing outlet tees, the Biotube Insert Filter is ideal. And for low profile tanks, there's the Base Inlet Filter. Covered by patent numbers 5,492,635 and 4,439,323 To Order Call your nearest Orenco Systems" Inc. distributor. For nearest distribu- tor, call Orenco at 800-348-9843 or go to www.orenco.com and click on "Distributor Locator." APS -FT -1 Rev. 3.4 ©11/10 Orenco Systems®, Inc. Standard Features & Benefits • Has 5-10 times • Easy to clean by more flow area simply hosing off than other brands, whenever the tank so lasts many needs pumping times longer • Removes about between clean- two-thirds of sus- ings, increasing pended solids, on homeowner average, extending satisfaction drainfield life • Installs in min- o Corrosion -proof utes inside new construction, to or existing tanks; ensure long life extendible tee retention time handle for easy • Lifetime warranty removal • Custom and Optional Biotube Features & Filtering Benefits Process • Alarm available, to Effluent from the signal the need for relatively clear zone cleaning of the septic tank, • Flow modulating between the scum discharge orifices and sludge layers, available to limit horizontally enters flow rate leaving the Biotube Effluent tank, mitigat- Filter. Effluent then ing surges and enters the annular increasing space between the retention time housing and the Biotubes, utilizing • Custom and the Biotubes' entire commercial sizes surface for filtering. available Particles larger than the Biotube's mesh are prevented from leaving the tank. Orenco Systems Incorporated Changing the Way the World Does Wastewater" www.orenoo.com Item 0 1000T -241'06P Top View Section View 1000 Gallon Top Seam Two Compartment 20" Clear A •d .• I (Big Hole Lid & miser) �......... 106" - Rubber elant Digging Spew Invert Dimension 11' Long x T Wide Inlet Outlet Length Width *Meets ASTM C-1227 spec 560 below inlet invert 56- 53- 111• 60' including C-1644-06 for resilient connectors • 6000 psi concrete • Delivered complete with internal piping • PVC, poly or concrete risers available • Option of pump or siphon installed Net Ca Inlet Slds Outlet Side Total 687 gallons 323 gallons 1,010 gallons Net Weight Lid Tank Total 2,620 The 9,380 be 12.000 In Page 3 Mechanical room drains should not discharge into the OWTS. The OWTS is engineered for domestic waste only. INSTALLATION OBSERVATIONS CBO Inc. must view the OWTS during construction. The OWTS observation should be performed before backfill, after placement of OWTS components. Septic tanks, distribution devices, pumps, dosing siphons, and other plumbing, as applicable, must also be observed. CBO Inc. should be notified 48 hours in advance to observe the installation. LIMITS: The design is based on information submitted. If soil conditions encountered are different from conditions described in report, CBO Inc. should be notified. All OWTS construction must be according to the county regulations. Requirements not specified in this report must follow applicable county regulations. The contractor should have documented and demonstrated knowledge of the requirements and regulations of the county in which they are working. Licensing of Systems Contractors may be required by county regulation. Please call with questions. Sincerely, CBO Inc. &V . 68 S Carla Ostberg, MPH, REHS Page 2 Calculations: 1 bedroom x 75 GPD x 2 people = 150 GPD Septic Tank = 1000 gallons 150 GPD / 0.5 gal/SF (Soil Type 2A) = 300 SF Gravity, pipe and gravel bed = 300 SF x 1.0 x 1.2 = 360 SF STA = 360 SF In summary, the system appears to be sized to accommodate a 1 -bedroom residence under current OWTS Regulations. This letter does not address soil analysis beyond the information documented on Pitkin County's Permit Number 78044 and is the basis of our assumption. DESIGN SPECIFICATIONS We recommend installing a double -sweep clean out on the existing sewer pipe within 5 -feet of the barn. The sewer pipe from the barn to the septic tank should be checked to assure there are no bellies or low spots that could hold standing water and cause freezing. The sewer line must have a minimum 2% grade from the barn to the septic tank. If this line is found to have improper grade or found to be in poor condition, it must be replaced. The existing septic tank must be properly abandoned by pumping it and either removing it or collapsing the top and sides and filling the void with gravel, sand, or compacted soil. The filled excavation must be graded to surroundings, allowing for settling. A new, minimurn 1000 -gallon, two-compartment concrete septic tank must be installed. An effluent screen (Orenco(D Biotube Effluent Filter) must also be installed on the outlet tee of the septic tank. This screen must be cleaned annually, or as needed. Specifications for the above mentioned components are enclosed. The new septic tank will be installed on in the location depicted on the enclosed plan. The sewer pipe exiting the septic tank must be checked to assure it is in good condition and clear to transport effluent from the septic tank to the STA. If the existing sewer line if found to be in disrepair or clogged, it should be replaced or jetted. The existing STA should be tested by running approximately 100 gallons of water from a garden hose through the sewer pipe. If the STA does not accept the water, this office and Pitkin County Environmental Health Department must be contacted. The component manufacturers are typical of applications used by contractors and engineers in this area. Alternatives may be considered or recommended by contacting our office. Construction must be according to Pitkin County Onsite Wastewater Treatment System Regulations, the OWTS Construction Permit provided by Pitkin County Environmental Health Department, and this design. OPERATION INFORMATION AND MAINTENANCE The property owner shall be responsible for the operation and maintenance of each OWTS servicing the property. If an effluent filter or screen has been installed in the OWTS, we recommend this filter or screen be cleaned annually, or as needed. If the OWTS consists of a pressurized pump system, we recommend the laterals be flushed annually, or as needed. The homeowner should pump the septic tank every two years, or as needed gauged by measurement of solids in the tank. Garbage disposal use should be minimized, and non -biodegradable materials should not be placed into the OWTS. Grease should not be placed in household drains. Loading from a water softener should not be discharged into the OWTS. No hazardous wastes should be directed into the OWTS. CBO Inc. 33 Four Wheel Drive Road Carbondale, CO 81623 X} cell) 970-309-5259 office) 970-704-0484 carla.ostberg(Dgmail.com June 16, 2016 Travis Hughes Travishuahes501 areaaan.com Septic Tank Replacement Design (Barn) 26150 Hwy 82 Pitkin County, Colorado Travis, Project No. C1219 CBO Inc. has completed a design for the replacement of the septic tank for the subject detached barn. During recent excavation on the property, the existing 1000 -gallon septic tank was damaged and must be replaced. The 132.24 -acre property is located outside of Basalt, in an area where onsite wastewater treatment systems (OWTSs) are necessary. Legal Description: Section: 21 Township 8: Range: 86 in Tracts 65 66 67 & 68, Said Tracts being Parts of Secs 21 22 27 & 28-8-86 known as Parcel No 2 & Cont 141.087 AC M/L BK 347 PG 213 LESS 0.55 AC Strip along Hwy 82 to Colo Dept of Trans now considered part of Hwy 82 R -O -W Parcel ID: 2467-214-00-009 SITE CONDITIONS The property is developed with a main house and a detached barn. The main house is served by a separate OWTS, documented by Pitkin County Health Department Permit Number 78045. The barn OWTS is documented by Pitkin County Health Department Permit Number 78044. Both systems were inspected by CBO Inc. in February 2013 prior to sale of the property. Both inspection reports are enclosed. It does not appear that an OWTS Use Permit was obtained prior to transfer of the property. A private well serves the property. This well is located greater than 100 -feet from the OWTS components. EXISTING OWTS (Barn) According to records provided by Pitkin County Environmental Health Department, the subject OWTS consists of one 1000 -gallon, two-compartment Copeland concrete septic tank followed by a 30' x 30' pipe and gravel soil treatment area (STA), or 900 square feet (SF). The permit notes that the system was designed to accommodate an office and bathroom in the barn. However, a 1 -bedroom apartment with a 3/4 bath exists in the upper level of the barn. This living area existed when the current owner purchased the property. With a documented percolation rate of 40 minutes per inch (MPI) we can assume a soil type 2A (Sandy Loam, Loam, or Silt Loam) under current OWTS Regulations. A tract of land situated .n Tracts 65, 66,,67, 68, said tr'a,-ts being parts of Section 21, 22, 27, 2:3, TBS, W of the 6th P.M., Pitkin Caunty, Colorado, i containing 141.087 ore or less. TANK: YES i Tank 1 1 Tank 2 ) PASS b Tank 3 Tank capacity 000 gallons ng, both visible and audible?' gallons FAIL gallons Tank material C # of compartments Date of last pumping a ) Lids/risers in good conditi<an P FAIL PASS FAIL PASS FAIL Risers to grade YES NO ;' YES NO YES NO Riser height ?D Riser condition/watertighf-iess a.r Inlet sanitary T/baffle PASS FAIL PASS FAIL PASS FAIL Outlet sanitaryl/baffie PASS FAIL PASS FAIL PASS FAIL Effluent filter (if part of d ign) PASS FAIL " N/ PASS FAIL N/A PASS FAIL N/A Condition of tank material PASFAIL PASS FAIL PASS FAIL Tank was pumped for inspE%ction YES NO YES NO YES NO If YES, list the pumping company6-C) � If NO, when was the last pumping J✓>�r s,r Zr,-) 1, Scum level (1st compartmE'nt) } j/ inches inches inches Sludge level (1st compartrrent) t inches inches [ inches Scum level (2nd compartment) off inches inches inches Sludge level (2nd compartment) Q to inches inches inches Backflow (if pumped) PASS FAIL PASS FAIL PASS FAIL Midtank baffle AS FAIL N/A PASS FAIL N/A PASS FAIL N/A Watertightness t _„ � FAIL PASS FAIL PASS FAIL PUMPS/DOSING SIPHONS:' Is a pump or dosing siphon If YES, is the pump/dosing Does the pump/wiring/dos Is the high water alarm wo SECONDARY TREATMENT: Is a secondary treatment ur If YES, does the unit appea Does the owner have a cur Maintenance Provider: If there is no maintenanti copy of the contract r' 'esent? YES NO Ghon functioning properly? ) PASS b FAIL siphon appear to be in goo condition? PASS FAIL ng, both visible and audible?' PASS FAIL it present? YES NO UNKNOWN to be in good working condition? YES NO ent maintenance contract for the unit? YES NO UNKNOWN I Phone: e contract, a contract must be,in place prior to occupancy of the hoose. A must be submitted to Pitkin Co�untY Environmental Heolth Department. ABSORBTION AREA: Effluent surfacing? Evidence of past surfacing?' Surface dampness? Excessive odors? i Field location verified by ob° ervation ports or probing: Liquid in observation port? If YES, record dE pth: Distribution Box or ADV part of original design? If YES, is it acces-3ible from grade? Is it level and in ;ood condition? A S FAIL YES YES X10 YES orts Probing . ;. f W17I [ avd 'I/ i e W -r NO YES � ,P -Lk ea,., YES , E$ P 'k Page 2 inches PiN NO JJNKNOWN NO CLV$ 1 FAIL I 4 zi —7 1C, Any problems with the sys9tem that were not addressed in(he —`1AA i inspection checklis ? Ple se list any recommencations for the continued use of �tA�, i -c tip the system: l` KKK Were any repairs done as a result of this inspection? If YES, please describe the -epairs. n, nu- - +-3 . tri Y + -3 NO YES _ - Tte F I _T the best of my knowledge and training, the informatio - e 20_' . Licensed Sy ems InspectorSignature: Additional Notes: collected in this inspection is accurate as of r �P, '' ai u . r(My�.R�. } R mh,.,.( .ate R4�*ciy W. fl S .M•F £ �` ,"A @ Egli pyEvi gyp` "? '� ii 4r y �s� {grN �'iy j i t -01 i bl:V £ .`1,F 4 O f IS, 3+� PERMIT NUMBER Owner Harry H. Baumann Owner's Mailing Address i Contractor Address System's Contractor's Name Address Legal Description ( See Revs Lot Size 140 acres Number of Bedrooms - Off ic+ , Owner's Signature ...,r.Harry H�--....n..-... 7 i .0. Box 5036, Snowma RECEIPT NUMBER t }^ � '' J ' 1 X923-3613 2300 Picone No. I e fi Village, CO 81615 Phone No. Typ° of Buildinq by Use Barn & 1 bathroomwell Vyl)0f!1 itillt1,N- Supply — Baumann (by C A.) 7 June 1978 Date PLOT PLAN: ATTACHED A� REQUIRED 4 ###-%##•Y. ?Fk#3F###?3##-.. ai#ri- #:;-n #. ',•r d: :: ... Y, .. :S :'� k4: c. ti' X'#3E#:#�haPr#•S##'k�Y'�f#;#-Ki'.�7E#_.##3f�#�#'�'�-###9F#####-SFF##-#iF{F## Type of Individual Sewage Di-j)osal System Type of Soil or Soil Classificat .:13 _ i r Proximal Location of Bedrock Proximal Location of Ground Percolation Test Date,/.! Minimum Recommended Abs d dT L� Tahle G' Minutes Per Inch -prion System Size G114Z 4 c�rt/S Minimum Recommen a ofIT1 Size NOTICE Special Conditions of Issue: When praaarly signed for issuance, this application becomes your permit. Application valid one year from daw Ifo of individual which h sewage disposal arnlit Is issued for propalty on which no building permit has been issued, thr Individual sewage disposal permit shall expire 12V days after Its issuance If construction has not boon �;ornmencod. Any change in plans or epeci- fieations after the permit has boon issued invalidates the parmh, unless approval Is secured from the Health Officer for�guch chan s. Approved for Issuance ByDate :F9F#R'§i#iFd!'•k'#+ki'F###{i'+k#dF-!F#iF###-&5..k#.1'7F#�\Ai-1,4 fi4###-ib####i[-#JX #ii'#'%'"X'#+k#?4##!"R"X'#:f''Q"1y##iF�`&•%•'k'k -%'z##ii ?.''ii -:•'3i FINAL - INSPECTION APPROVA (Drawing of System on Stack) A tract of land situa Section 21, 22, 27, 2 containing 141.087 ad ori Tracts 65, 66, 67, 68, said traits being parts of T8S, W of the 6 h P.M., Pitkin C)unty, Colorado, ore or less. 1j �n6 t - -4, 9 February 11, 2013 Ron Kanan rkanan(a),aol.com CBO Inc. 33 Four Wheel Drive Road Carbondale, CO 81623 cell) 970-309-5259 office) 970-704-0484 cbo2610@yahoo.com Onsite Wastewater Treatment System (OWTS) Use Permit Inspection 26150 Hwy 82 Pitkin County, Colorado Mr. Kanan, As requested, CBO Inc. performed an Onsite Wastewater Treatment System (OWTS) Use Permit inspection at 26150 Hwy 82, Snowmass, CO on January 29, 2013. The subject OWTS consists of one 1500 -gallon two-compartment septic tank. Only the inlet compartment was viewed as part of the inspection, as the other manhole lid was frozen and unable to be lifted (see pictures). The absorption area consists of 1400 square feet of pipe and gravel, according to Pitkin County records. There was a significant amount of snow cover present at the time of the inspection. The permit and as -built drawing were provided by Pitkin County Environmental Health Department. (Parcel ID # 2467-214-00-009) The septic tank appeared to be in good condition, with built-in concrete baffles in place of tees. The baffle on the inlet side of the tank was observed and there was no sign of deterioration. The outlet baffle was not observed, but assumed to be present. I would be happy to return to the site in the spring and remove the lid to complete the inspection. The absorption arE:a showed no signs of saturation, and had no indication of failure. Observation ports were not observed. This evaluation is not a guarantee of future system performance. This inspection is good for one year. This report should be submitted to the Pitkin County Environmental Health Department. The following links are the required application and application checklist. Application: http://www.aspE)npitkin.com/Portals/0/docs/county/Com%20Dev/EHNR/OWTS°/o20Use%20 Permit%20Application.pdf Application Checklist: http://www.aspE)npitkin com/Portals/0/docs/county/Com%20Dev/EHNR/OWTS%20Use%20 Perimt%20Application%20Checklist.pdf Please call with questions. Sincerely, Carla Ostberg, MPH, REHS NAWT Certified Inspector Certification # ITC11042010 Exp. 2014 View of tank lids looking toward field area and barn. let side of tank Inlet side of tank Outlet side of tank View of tank lids looking toward main house. Outlet compartment lid set into the riser. Lid was frozen in place and unable to be removed without risk of breaking lid. Lids were approx 6" thick and extremely heavy. Inlet compartment of tank w/ concrete baffle k View of tank lids looking toward field area. FAL' EXAMPLE of lid thickness, making them very hard to lift. tAu'l cI h 5 wz> L �K IN Onsite Wastewater Treatment Systems (OWTS) Use Permit Inspection Forin COUNT4 Pitkin County Environmental Health Department 76 Service Center Rd, Aspen, CO 81611 Phone: 970-920-5070 Fax: 970-910-5374 Website: www. aspen 12itkin. cory eh n r Instlection form for continued use of an existing OMITS Owner's Name: Address: Parcel Number: 2-1 L-) — DD_ inspection Date: 20 1 1,,r Inspector's Name: r cx, IGJ,o,,� Business Name: jtj AC Phone Number 2,A `1- -2-1 4—bO—W!�) Email: c.f.ViVI Pitkin County Systems Insp'ctor License Niu—r6iier: posses or fails. QUESTIONS FOR PROPER OWNER PRIOR TO INSPECTION: is the home currently occupied? YES NO;, If No, how long has the home been vacant? V,-Ar>,v-r G1 C�G,7 How many bedrooms are it the home? n f rj If secondary treatment is used, who is the maintenance provider? RECORDS: Were system records availzible from Pitkin County? (YES:) NO If YES: Permit number 7? w] 5 Date of Final A proval: 11 1 D 1-7 C) # of bedrooms ermitted: Was an as-built�ldrawing available? YES NO Y is the as -built drawing accurate? YES NO If NO: Complete a drawing of the system on last page of this form as occur hely as possible. Any question markei I FAIL will require correction before an OWTS Usig permit is issued. SITE CONDITIONS: Proper grading, no eviden e of erosion? ASIS FAIL Improper vegetative cover p NO YES Evidence of compaction such as heavy machinery or livestock? NO' YES Improper discharges such is straight pipes? PASS FAIL 0 Evidence of high ground water? NO YES Snow cover present? NO YES Page 1 TANK: Tank 1 Tank 2 Is a pump or dosing siphon resent? Tank 3 YES NO � Tank capacity If YES, is the pump/dosing s phon functioning properly? gallons PASS FAIL gallons Does the pump/wiring/dosi g siphon appear to be in good condition? gallons Tank material - PASS FAIL SECONDARY TREATMENT: Is a secondary treatment unit present? # of compartments ___ N�_.1 UNKNOWN If YES, does the unit appear -to be in good working condition? YES NO Date of last pumping YES NO UNKNOWN Maintenance Provider:_; Phone: Lids/risers in good condition PAS FAIL PASS FAIL PASS FAIL Risers to grade YES NO YES NO YES NO Riser height c Surface dampness? Na_,)ES Riser condition/watertightnr?ss= YES _( M f Field location verified by o ervation ports or probing: Ports Probing YES Inlet sanitary TJ ;a Outlet sanitary T/baffle PA55 " PASS FAIL FAIL PASS PASS FAIL FAIL PASS PASS FAIL FAIL Effluent filter (if part of design) PASS FAIL NJA PASS FAIL N/A PASS FAIL N/A Condition of tank material ` PASS-, FAIL PASS FAIL PASS FAIL Tank was pumped for inspe tion YES NO YES NO YES NO If YES, list the pumping comany to If NO, when was the last pumping-2-1fi�E '2?] Scum level (1st compartment) Q" inches inches inches Sludge level (ist compartment),`" " inches inches inches Scum level (2nd compartment) inches inches inches Sludge level (2nd compartment) inches inches inches Backflow (if pumped) —PASS --1— PASS FAIL PASS FAIL Midtank baffle S - FAIL NJA PASS FAIL N/A PASS FAIL N/A Watertightness ;PASS' FAIL PASS FAIL PASS FAIL PUMPS/DOSING SIPHONS. Is a pump or dosing siphon resent? YES NO � If YES, is the pump/dosing s phon functioning properly? PASS FAIL Does the pump/wiring/dosi g siphon appear to be in good condition? "' PASS FAIL Is the high water alarm wor ing, both visible and audible? PASS FAIL SECONDARY TREATMENT: Is a secondary treatment unit present? YES._ ___ N�_.1 UNKNOWN If YES, does the unit appear -to be in good working condition? YES NO Does the owner have a current maintenance contract for the unit? YES NO UNKNOWN Maintenance Provider:_; Phone: If there is no maintenance contract, a contract must be in place prior to occupy ncy of the home. A copy of the contract rust be submitted to Pitkin County Environmental Hef th Department.. i ABSORBTION AREA: ��:--�` PASS FAIL Effluent surfacing? _ Evidence of past surfacing?; (LN 0 YES — Surface dampness? Na_,)ES Excessive odors? t� NO? YES _( M f Field location verified by o ervation ports or probing: Ports Probing YES { 'Ad - a Ipfvx � CCx W Liquid in observation port?NO _ If YES, record d pth: inches _ A51 d Distribution Box or ADV part of original design? YES CNKNOWN per rt arrd If YES, is it acce sible from grade? YES NO n Is it level and in good condition? PASS FAIL Page 2 Any problems with the systE mthat were not addressed in the inspection checklist? r a Please list any recommendations for the continued use of the system: Were any repairs done as a result of this inspection? NO If YES, please describe the rpairs. YES Teo—the best of my knowled€fie and training, the information collected in this inspection is accurate as of 20 ( 3, . Licensed Systerxinspector;Signature: t� Additional Notes: Clearly label any pictures and attach them to this form. Page 3 dM " PERMIT NUMBER –P—,�— Owner T 7 LE , 9 Owner's Mailing Address Contractor Address --L System's Contractor's Name Address Legal Description - Lot Size _T Z:6 iy E Number of Bedrooms Owner's Signature PLOT PLAN, ATTR{,HE A RE PITKIN COUNTY HEALTH DEPARTMENT RECEIPT NUMBER Phone No. �� 5"�/� Phone No. Type of Building by Use Type of Water Supply Date --� 4, Type of Individual Sewage DisFosal System Type of Soil or Soil Classification <���- 40 Proximal Location of Bedrock V Proximal Location of Ground II( ater Table Percolation Test Date Minutes Per Inch Minimum Recommended Absorption System Size ` � � j3s1[ jQo d Reap,���t/� Minimum Recommended Tan 1 Size %sof> CAI- Special Conditions of Issue: j4gs,q,ePr14PA1 Aly NOTICE When pro3orly signed for issuance, this application ate. If your permit. Application valid one year from dta. daIf an individual sewage disposal permit is issued / for property on which no building permit has been /Os / //f 0--A } issued, t U individual sewage disposer permit shall as j7rf� (j,,fr1/ E/(f expire 72(� days �'ar its issuance if construction has not been :ommanced. Any change in plans or spaci- r fications Efter the permit has been issued Invalidates the permlt, unless approval is secured from the Health Approved for Issuance By J FINAL INSPECTION APPROVALLIZ (Drawing of System on Elack) Officer for such changes. r / Date Date 0 4 4- O0 M rL 0 41 u 4-3C .r- iCS -r 00 �o cu 41 Ln iG 4- 0 (1) Cd ltd S- m CG co o S - CV) 0 R-� r V) 4-3 00 5 - to CIO -41 4- r cn 0 01 c 4J C C: S- +3 4-� 4-3 Q r- 0) 0 V) u AS's I :mac PIT NJ Ll V, I