Loading...
HomeMy WebLinkAboutpitkin.eh.264504200003 (1988)ASPEN*PITKIN ENVIRONMENTAL HEALTH DEPART MENT -L 6LI 5-- U ti a- - p () -- (563 5$'6I E Srr i& 6VA INDIVIDUAL SEWAGE DISPOSAL PERMIT N0, TYPE OF PERMIT: ( )Initial Construction ( )Emergency Use ' Repair Work,(Pceviou■ Permit 1 .) ( )Alteration of an existing syutem, or installation (Previous Permit 1 ) ( )Use Permit as a result of Sale ( )Othorr ISSUED TO: DATE OF ISSUEA -- �?18 1�s Owner (So,,,-,G0r—q CEW l S Home Phone q �17- X;3 Business Phone Mailing' Address 2.fCRS Sn 6 -t1h ttSS L L Agent_ Ma i l.in g Address Sewage Disposal System Work to be performed by Phone This permit valid only for premises location by the following legal descriptions J-!. '; W, F. �6 LOT SILE (�L(L(� LJ , WATER SUPPLY P, A,)A6C LL)( LL- AVERAcr PERCOLATION RAT ` N _ This Individual Sewayc Disposal Permit is granted with regard to the following use: SiAiG LC t'AMILQ ICM SI LCLzY'C Ntr!aber of: Dodreoms _ 7 Lofts Carbage Disposals Dishwashers Clothes Washors ' e_ CALCULATED AVERAGE DAILY WASTE LOAD / (_, GALLONS. THE IVATLrRE OF THE SYSTEM INCLUDED UNDER THIS PER111T: Type of Tank or Treatment Units iS"rr.l r Ts<u1� Tank Capacity �� _Callon Minimc:a Incthod of Final Di3po33lt e T�Q ��. j5T/Absorptiop. Area J, 2; S�q"uare Feet. Minimum Description (including brand' n✓ams, if any) of other equipment or appurtnaneest �irjS��LL A94'1' I A-1 (ip5(.�, 41J /I as VN dest�N t r cv Other Conditions or Spccificationsr Stl4l.� �S p�R- i�e'`/n) ✓+� SCffnUe5ap— Go.�phi Ne��• � �.J�� STAGES REQUIRING INSPECTION BY THE HEALTH DEPARTMENT: ' ( )Before Excavation ( )Upon completion of excavation and prior to placement of gravel ( )Before covering distribution system of absorption field h(]Prior to backfill of .any component ( )Other, Specifyr Plan/sand specifications of the proposed sewage disposal system have been reviewed and are considered satisfactory. Pernissi.on iK hereby granted to the owner or his agent to perform the work indicated above in accordance with the Pitkin County Indivi;ival Sewa;e Disposal Rc,;ulations in effect on the date of issue. In addition to general provisions set forth on the reverse her=or, this Permit is subject to the following additional terms and conditions: APPROVED FOR ISSUE BY r �(title) &01121,t1 Atn>fdt(c?Aof tt " The a)xive in:iividual seva,lo disposal system installed by has bren in:g,c cted for use by a representative of the Aspen Pit in Unvironrniita Health Dep•%rtnuiC. TFC ownor as:rumos a ll rec:ponsib).lity in case of failure or inadequacy of thisewago disposal system. Complete as -built drawing attached. fes- 6 -Z3 - $� Or_ - uee� �S. I�� DATE OF FINAL INSPECTION V TITLE _ 130 South Galeria Street ,/ Aspen, Colorado 81611 303/925-2020 ASPEN*PITKIN 250 ENVIRONMENTAL HEALTH DEPARTMENT APPLICATION FOR AN INDIVIDUAL SEWAGE DISPOSAL•PERMIT Name of OWNER PHONE Address of OWNER v f2QM__� C-' L- C A,`)MCI'`6 CED Name of APPLICANT C)_ -:!S cJbCLfzi PHONE PERMIT TO BE: ( )Picked Up ( )Mailed to: TYPE OF PERMIT: ( )New Installation ( iRepair ( )Owner ( )Applicant . ( )Emergency use (.)Alteration NOT due to failure LOCATION OF PROPOSED SYSTEMS L — Legal Description Lot Block_ riling Subdivision Sixe of Lot ,'�i (, (CIL(. acres TYPE OF STRUCTURE: Single Family Dwelling ( )Other: Do you plan any further` additions to the 5, residence? ( )YES (X1NO r No. of bedrooms_ No. of Lofts No. of Garbage Disposals 1 No: of Automatic Dishwashers I No, of Automatic Clothes washers i )PATER SUPPLY: 0 Private Wall, Depth 2G1 or ( )Public, Name of System ( )Spring ( )Stream or Creek TYPES OF INDIVIDUAL SEWAGE DISPOSAL SYSTEM PROPOSED: (.)Septic Tank/Absorption Field ( )Aeration Plant/Absorption Field ( )Composting Toilet ( )Incineration T ilei (.)Mound (')Recycling, potable use ( )Recycling, other use ( )Vault Privy Other:L The initial site inspection must be arranged with the Aspen/Pitkin Environmental Health Department (925-2020. 8:30-9:30 a.m.) before a permit can be issued. The individual sewage disposal permit must be issued before a building permit can be obtained. FINAL INSPECTION APPROVAL MUST BE GIVEN BY THE ASPEN/PITKIN ENVIRONMENTAL HEALTH DEPARTMENT PRIOR TO BACKFILLING ANY PORTION OF THE SYSTEM. Application for an individual sewage disposal permit is hereby submitted. The undersigned acknowledges that the above information is true and that false info mation will Zi,date the application and any subsequent permit. Signature of Applicant s �`s� :2 DATE (This application becomes. invalid 11 months from the above date.) NOTE: PLOT 'PLAN must be filed with this application. Please locate the following items by measured distances: 1. Property lines and dimensions. 2. Proposed and existing water wells on subject property and adjacent property. 3. Domestic water service lines. <. Proposed and existing buildings, driveways, and other Structures. S. Streams, lakes, ponds, irrigation ditches, and other water courses. 6. Proposed and existing individual sewage systems on subject property. SUBMIT A REVISED PLOT PLAN PRIOR TO CONSTRUCTION IF INSTALLATION IS TO BE CHANGED FROM ORIGINAL PLAN. The undersigned hereby acknowledges receipt of this individual sewage disposal permit application and a permit /fee in the amount of S ,(fi.Receipt Number , Date Fee Received .by A% \ Administrativo officer 130 South Galena Street Aspen, Colorado 81611 303/925-2020 rad PITKIN COUNTY ENVIRONMENTAL HEALTH Field Test Data Sheet on Percolation Test PROPERTY OWNER PHONE MAILING ADDRESS LEGAL DESCRIPTION OF PROPERTY LOCATION OF TEST HOLES_ 4 "�-- Three (3) test holes required per system Test Hole Depths (24" minimum) Diameter of Test Holes Water remaining after 8 hour soak dk,+ _K ;6� Wim.e. TEST HOLE No.1 TEST HOLE No. 2 TEST HOLE No. 3 Drop Time Drop Time Drop Time 3 0 36 t — - Percolation Rate Each �Hole L4, L4 U 1 Np , !'[, II +`y� Average Rate aC n Comments on soil or site: Date 27 Signature �" J�� H P x MI FIN/SHED GRADE PROVIDE SWALE TO DIVERT RUN-OFF AROUND ET/A BED EXISTING 1250 GALLON \ \ SEPTIC TANK \ _. INSTALL ADDITIONAL 250 GALLON SEPTIC TANK WHEN 5rN BEDROOM /S ADDED SEE NOTE A; ADD/T/ONAL DOS/NG EXIST/NG TANK, SEE DETAIL DOSING TANK o \ EXIST/NG BED — TO BE ABANDONED EXISTING DRYW£LL TO 8£ ABANDONED � C-�1C(-,co EXISTING 2" PVC PIPE WATER TANK 4 ET/A BED SEE DETAIL \ \ \ PROVIDE SWALE TO J DIVERT RUN-OFF AROUND \ ETIA BED NOTE - A) REMOVE LINE TO DOS/NG TANK AND RE-ROUTE INTO 250 GAL. SEPTIC TANK WHEN 5n' BEDROOM IS ADDED, TIE 250 GAL. TANK INTO 5-0 DOSING CHAMBER. B) GENERAL PLAN /S ONLY A SCHEMATIC, VERIFY DIMENSIONS IN FIELD. �APPROX/MATE LOCATION OF TOP OF EXIST. FILL GENERAL PLAN E'VAR- 0- TRA NSP/RATION 1 ABSORPTION BED N T.S. BOTTOM OF BED TO BE — CONSTRUCTED IN NATURAL GROUND, BELOW TOPSOIL r� I T_ II �� EX/ST. 4 ¢x5DEEP DOSING CHAMBER PUMP GROUT WATERTIGHT � � MATCH — — _ EX/STING �— — — — DEPTH MANHOLE LID B COVER PRECAST CONC. LID h PROPOSED DOSING CHAMBER PRECAST CONC. MANHOLE SECTION 4 " CIP BETWEEN DOSING CHAMBERS CAST /N PLACE CONC. BASE DOSING TANKS DETAIL SCALE - NOTA ASSURE THAT NO HEAVY TRAFFIC (I. e., VEH/CLE OR LIVESTOCK) IS ALLOWED ON TOP OF BED. 42' -^+- --6-- --- 6 - -r- - 6' -6'- - BE LEVEL O./' ; SCAR/FY BEFORE PLACING ROCK SEC TION A -A SCALE: /'; 4' Z " PERFORATED I'VC SLOPE O"/FT (T YP.) /J-OFJff">o2s" CLEAN ROCK EXISTING EAR, rH FILL / TO BE REMOVf_D AF/ FABRIC OR OF STRAW PROVIDE SWALE TO DI VERT RUN-OFF AROUND ET/A BED / GROUND SURFACE PR/OR TO / APPL ICA TION OF EARTH FILL s2' 2' A/R VENT (2 REO D) f SEE DETAIL 2" SOLID WALL PVC - SLOPE O "IF T- b 2" PERFORATED PVC SLOPE O"/FT. (TYP.)� to 2" PVC FROM DOS/NG TANK . co i b M N.; f ET/A BED DETA/L SCALE: /'= /O' lIYI►Ipal i • 1. System is based upon a combination Absorption (A) and Evapo- transpiration (ET) Svstem. 2. All materials, installation practices, setback requirements, etc., shall comply with the Pitkin County Individual Sewage Disposal System Regulations. 3. The E. T. bed shall be constructed so that the bottom ds level + 0.1 inches. Place bed in natural ground; no portion of the bed shall be placed in fill. 4. Provide adequate surface water diversion to assure that runoff does not enter the evapo-transpiration bed. 5. Stone shall be 1/2" to 2-1/2" screened rock. 6. Sand shall be 0.5 to 1.0 mean effective size with a uniformity coefficient of 4 or less. 7. The recommended bed seeding is blue grass at 4 to 6 lbs/1000 sq.ft. All other areas disturbed by cons tructruction shall be reseeded with native grasses to prevent erosion. 8. The location of the bed may be adjusted in the field to better fit the site, provided all setbacks are met. 9. If the last hole, based on 30 -inch spacing, is equal to or greater than 15 inches from the end of the lateral, put another hole in the end cap of the pipe or close to it. 10. Use risers as needed to bring septic tank access hate•.-.rithin 6" of finished grade. 11. Cast iron pipe or pipe of equal strength or other pipe properly supported to prevent failure by settling shall extend from tank for- a distance of at least five feet (5') from the inlet and outlet ends. 12. The Contractor and Owner shall take whatever measures are necessary to assure that (a) septic tank and sewer lines are conpletely water tight, and (b) the system is to be installed to preveit freezing of all pressure and gravity sewer lines. 13. The location of existing utilities must be verified by Contractor prior to commencing work. 14. The Pitkin County Environmental Health Department ane the Engineer shall be notified when construction commences and kept abreast of the construction progress so that sufficient inspection can be performed to assure conformance with these plans. SANDY TOPSOIL VARIES FROM 6" AT CENTER TO 2" AT EDGES i 4 - TEE DO NOT GLUE 4 "AIR VENT AIR VENT DETAIL Design Criteriar"� C.`✓v 1. Number of bedrooms = 5 2. Assume 2 persons/bedroom and 75 gpcd 3. Flow = 750 gpd 4. Perc = 60 min/inch 5. Loading for absorption area: 60 min/inch = 0.30 gal/sf/day 0.30 = 0.154 loading 1.95 6. Loading for ET area: A = Q (237) 1 = O (237) 32 32 Q = 0.135 loading 7. Total loading for ETA System = 0.154 +0.135 = 0.289 gpd/ft2 8. Area = Flow - Loading = 750-t 0.289 = 2,595 S.F. bed size.