Loading...
HomeMy WebLinkAboutpitkin.eh.264504301013 (2000)Ashen/Pitkin Environmental Health Department Permit for an Individual Sewage Disposal System 130 S. Galena St. Aspen, Colorado 81611 Phone 970-920-5070 / FAX 970-920-5074 Permit # 00021 Parcel ID # 2645-043-01-013 Type of permit New( ) Repair( x ) Addition to House( x ) Name of Owner George and Jamie Mahaffey Street Address 271 Little Elk Creek Ave Property legal description Lot 10, Block 3, Filing 2, Little Elk Creek Subdivision Size of lot 2.17 acres Total square footage of the house 2716 Water source Little Eik Creek Water system # of bedrooms in house 3 # of offices, lofts & similar sized rooms in house 1 Caretaker unit No Total square footage of the caretaker unit # of bedrooms in caretakE!r unit # of offices, lofts & similar sized rooms in caretaker unit Designed for what # roorrs (list) 4 Permit information Designed by McLaughlin Engineers, Dean Derosier Mailing Address 111 P AABC, Aspen, CO 81611 Perc rate mound Profile hole depth n/a Depth to groundwater or bedrock 1 foot to groundwater Septic tank capacity 1750 Absorption area 1200 square feet (24x50) Comments Septic permit approved per compliance with the engineer design and specifications dated August 10, 1999. Any changes must be approved by this department and the design engineer prior to them being made. Minimum horizontal distances between components of the system and physical features shall conform to the Pitkin County ISDS regulations. The system will consist of the existing 750 gallon tank with an additional 1000 gallon tank and a 750 gallon dosing tank. Due to high ground water, the field will be a mound system with approx 2.75 ft of sand fill and 9 inches of gravel to bring the system a minimum of 4 feet above groundwater. Sand and gravel must meet engineer's specs. This department does not endorse any brand of products. The engineer must do a final inspection of the installation and submit an as -built letter to this department. This department must also be called for an inspection with a minimum of 48 hours advanced notice. Permit approved by: ((�( iG�' (f-5 L nL: Date: '511E, -loo Plans and specifications of the proposed individual sewage disposal system have been reviewed and are considered satisfactory. Permission is hereby granted to the owner or the agent to perform the work indicated in accordance with the Pitkin County ISDS Regulation in effect at the time of issue. This permit becomes invalid 6 months from the date that the permit was issued unless system construction has commenced or an extension has been approved in writing by the Department. As -built drawings must be included with this permit before the final approval will be issued. Installer: Final inspection approval: 1-1C) o vvt,6ukr 4 ) -11 by �e,.% ►� �� 1. . ASPEN/P"-,KIN ENVIRONMENTAL HEALTH DEPARTMENT APPLICA110 FOR INDIVIDUAL SEWAGE DISP( \L SYSTEM 130 S. Galena St., Aspen Colorado 816 1 Phone 970-920-5070/Fax 970-920-5039 Primary Contact Person (all communication regarding this permit will go through this person) Name Company Contact Mailing Address <� �N !+ S Business Phone : -Gell Phone '^ ^ � � Fax Parcel ID # (available from assessor's office at 920-5160 or at www.aspen.com/assessor/) Street address of property o?7/ Legal Description: Lot 1 D Block 3 Filing Subdivision i -f-1 �� J L Size of lot: c�• I -1 acres. Type of proposed structure: Total square feet of house Q- # of bedrooms in house # of offices, lofts & similar sized rooms in house Size of bldg. envelope: -77 Caretaker Unit: Attached ( ) Detached ( ) Total area(sq. ft.) of caretaker unit +1 of harirnnms in (nrP..takP_r unit # of offices, lofts and similar size rooms of caretaker unit Permit Is for: New Horne ( ) Repair due to failure (,}{) Remodel/Addition ( ) Emergency use ( ) Water: Private well ( ) Spring { ) Stream 0) Community/Public Water System;k) If community system: Name of system,(,rW IC EiL Lne. c �/,Ad /rte 5/rrrr The fee for a ISDS application is $330 for a permit that takes 6 hours or less for the department to approve. If approval takes longer than 6 hours, a rate of $55 per hour will be charged. The maximum fee is $1000. The basic fee of $330 is due at the time of application. The remainder, if any, will be due in two stages: first, at the time of issuance of the ISDS permit: second, before final approval of the ISDS permit. Application for an individual sewage disposal system is hereby submitted. I hereby certify that the above information is true and accurate and that I have provided true and accurate information on locations of all existing and proposed wells, contour intervals, buildings, property lines, ditches, slopes, waterlines, springs, suction or irrigation lines, drinking water cisterns, drain tiles, irrigation ditches, lakes, water courses, streams, floodpiains, dry gulches, and existing septic systems. I hereby certify that any such features not shown on attached site map are not present. Issuance of the permit does not imply the approval of any other permit required for construction pursuant to Pitkin County codes. No construction may be undertaken until all approvals and permits have been obtained. The Aspen/Pitkin Environmental Health Department, Pitkin County and employees of these agencies will be held harmless should the individual sewage disposal system fail or malfunction. The permit to construct is issued on information submitted by the applicant or his/her representatives. The owner assumes full responsibility in case of failure of the system. Signature of apl Received by Date Date `� �� C -pen / Pitkin Environmental Health Departo Contact Log Sheet �Address: I i Comments• to be Taken �. MW -12, - _11111' UP",�"_ _F�F / i /1.. _ 4 i Sent By: MCLAUGHLIN WATER ENGINEERS; 970 925 1974; Jan -15-01 11:03AM; Page 8/8 MNK1v1cLAUG11L1N WATER E;N'GFNTT:RS, ltd. 111 1' AA11C ASPEN, C 01,0RADu 81611 970-925-1920 970-925-1974 tax mweiupcnii[ rot nei MEMORANDUM Date. January 15, 2QQ1 To; Pitkin County Environmental Health, From: Dean Derosier; McLaughlin Water Engineers, Ltd. RR- Mahaffey Septic System Final • 99-419.01 - 271 Little Elk Creek Ave The septic system for the Mahaffey Home at 271 Little Elk Creek Ave has been installed by Dreager Excavation and placed into service. After Inspection of the system by MWE, it was found to be installed according to MWE's design and PCEH requirements. This letter is to serve as the acceptance letter for MWE and recommendation to Pitkin County for final acceptance of the system. The new system replaced the old ST Bed system that had failed. The system was full of holes, ineffective, and mostly seeping into the ground. A majority of the old sy®tam was removed as the new system was being installed. The new mound system was installed above the old system and 4' above the high ground water level. Plea a cal is you have any questions. G an sie C!ici\tnl\` 9 Oly, U1/eepLic Crll. Sent By: McLaughlin Water Engine-;, Ltd; 970 925 1974; Aug -2" 10 3:28PM; Page 2/2 AUG -21-00 MON 01:20 PM ASPEN/PITKIN ENV HEALTH PAX:970 920 5074 PACE 1 COMWX hnyiT0ntn2aW_HcaIth Deartmant 130 S. Galena Co 511, FAX TO: Phone: Fax Phone: CC: Dean Data; Number of Pages including cover sheet: PROM- Nancy MacKenzie Phone: 970-920-5076 Fax Phone; 970-920-5074 E'mail: nancym a ci.asAert.00.us IREMARKS. ❑ Urgent ❑ Foryourrewew ❑ Reply ASAP ❑ please Comment RE: George Mahaffey 271 Lithe Elk Ck Ave Dean, I am concemed that the Mahaffey mound was placed over the failed ET bed and the Et liner was not removed.. It could be that the liner was full of holes and completely Ineffective, however that is an unknown. Please be sure to state in your "as -built" letter again that this was done and why it should be OK. Thanks. gq IC}s h� T L McLAUGHLIN WATER ENGINEERS, ltd. 111 P AABC ASPEN, COLORADO 81611 970-925-1920 970-925-1974 fax mweaspen(a rof.net MEMORANDUM Date: August 10, 1999 To: Pitkin County Environmental Health; From: Dean Derosier; McLaughlin Water Engineers, Ltd. RE: MAHAFFEY Residence - Septic System Design Notes - LITTLE ELK CREEK - 99-019.01 The following are my design notes for the new Mahaffey Residence Septic System design. The site is a flat area next to the home at 271 Little Elk Creek. This system is replacing the existing system that has failed. Existing system is to remain in place, but abandoned. - 4 - Bedrooms (3 main + 1 future) - Approx. 3,000 Square Feet of living area - 100 gallons per day per person - A percolation test was not performed as ground water is 1' below existing grade. - Ground water 1'+\- feet from surface Flow = Q = 4 bed rooms x 2 peo/br x 100 gal/day/per x 1.75 = 1,400 gallons per day. This requires the new system to be 132 -feet from the well. Tank sizing - 4 - Bed Rooms requires 1,750 gallons of septic tanks; Q X 1.25 Reuse the existing 750 gallon tank and install one additional 1,000 gallon tanks in series for total 1,750 gallons of septic tanks. The new system will require a dosing tank to pump the effluent up to the proposed Mound system. An additional 750 gallon pumping tank is required in series with the two septic tanks. Dosing/pumping is to utilize a separate 750 gallon single chambered dosing tank. Dosing volume - 300 gallons per dose 2-3 times per day. Area of Septic field required = A A = Q\ Loading Rate of the soils to be brought in as fill. The Loading Rate, LR = 1.2 gallons pr Sq ft. per day. A = Q/LR = 1,400/ 1.2 = 1,167 square feet The mound system is shown on the attached drawing and discussed in further detail on the attached memorandum. System total size is - 80' X 571, with a disposal area 50' X 24' laid out to fit site conditions and meet all setbacks as shown on the attached drawing. Approximately 2.75' of sand fill and 9" of gravel will be required to be brought in to bring the system a minimum of 4' above the ground water. Approximately 1.5' of fill will be placed on top of the system. Tanks will be installed in the general area below the home. Tees will be installed on both the inffluent and effluent lines of the tank, set on the inside of the tank. Set top of line from tee within 1" of the roof of the tank and extend line downward 12" below center line of tee. Fill tank with water prior to backfill to check for leaks and leave water in tank for placing the system in service. Septic tanks will be a two -chambered tanks. Piping from the home to the tanks will be 4" SDR 35 PVC laid at a minimum of 1%. Insulate lines with less than 5 -foot of cover or in uninsulated crawl spaces. Distribution will be through a 2-1/2" Sch 40 PVC from the tank to the distribution manifold where 1" sch 40 perforated PVC will be run into each of the 12 rows (22' long each, 6 on each side of the manifold) of the Mound System. All piping to be bedded in a minimum of 2" under and 6" over of 3/4" screened rock. Adjustments to fit site contours and conditions may be made per approval of the engineer. Elevations of the tank and trenches shall be finalized in the field by the engineer. Installation and operation shall be approved by the engineers prior to final acceptance. System must meet all PCEH and MWE standards. Dosing pu7p,H,dr.0matic Sk 75 unit,( 90gpm Q --23' head) . G. lean Derosie gdd\mahaffey\99-019.01 McLAUGHLIN WATER ENGINEERS, ltd. 111 P AABC ASPEN, COLORADO 81611 970-925-1920 970-925-1974 fax mweaspen@rofnet MEMORANDUM DATE: August 10, 1999 TO: Pitkin County and George and Jamie Mahaffey FROM: McLaughlin Water Engineers, Ltd.; G. Dean Derosier,P.E. RE: Mahafeey SEPTIC SYSTEM DESIGN - Replacement This memorandum is written to give you additional details on the design, materials, and installation of a replacement Septic System which was designed to serve the Mahaffey home at 271 Little Elk Creek in Old Snowmass. The memorandum is separated into three sections; 1 - Septic tank and Mound System design, 2 - Effluent tank design, 3 - Installation and Materials for the system. The design drawing is also attached for additional reference. 1. Septic Tank and Mound System Design: The location of the home and the site conditions determined the required type of system which was to be designed. The site is located just above the water table in the Little Elk Creek Subdivision The difficulties encountered deal with the 1lIOIIIlI am to work with and included the existing system already in place, existing trees, and high ground water. These items lead to the design of a system which would use a standard septic tank and Mound System, and will require a pump to lift the effluent up to a flat area next to the home site for disposal. Please see my Memorandum dated August 10, 1999 for additional information on the new system and removal of the old system The system design was based on the ultimate construction of a 4 bedroom residence, which required at a minimum, the installation of a 1,750 gallon septic tank for the separation of solids and a dosing tank. The existing 750 gallon septic tank can be pumped and reused and add and additional 1,000 gallon tank as the main septic tanks (TOTAL 1,750 GALLONS), and a 750 gallon tank as the effluent pump/dosing tank. The main septic tanks are to be a double chambered tanks and the effluent pumping/dosing tank is a single chambered unit. The three tanks are to be installed in a series with the septic tanks first, followed by the effluent pump tank. The tank invert piping elevations are to be as shown on the attached design drawing and field verified. The water level, the dosing system, and the flow anticipated to utilized by the system determine the size of the Mound System required. Using 1.2 gallons per square foot, a flow of 1,400 gallons per day requires 1,167 square feet of septic disposal in the Mound System. The details of the Mound System; installation, elevations, and location are shown on the attached design drawing and sheets. The evanHfl system size will be 57 -feet X 80 -feet, the ISO field size is 244eet X 50 -feet. The transmission piping and manifold are to be 2 -1/2 -inch and distribution laterals to be I -inch. both Sch 40, PVC piping. The laterals are to be perforated piping, (1/4 -inch holes on 36 -inch centers), with`Nnches of gravel under and 2 -inches of gravel over the pipe. The sand depth is — 2.75 feet and is to be a medium sized sand with the following characteristics: 25%+ between 2.0 and 0.25mm; 30-35%- between 0.25 and 0.05mm; and 5-10% between 0.05 and 0.002mm. This sand is similar to the masonry sand available at Roaring Fork Sand and Gravel. Installation details and instructions are attached to this memorandum. Total height of the system is — 2.75' sand, 12" gravel, and 1.5' fill, for 5.25'. Effluent Pumping Tank: The effluent pumping tank is required to pump the effluent from the septic tank to the septic field in the terrace above the home site. The tank capacity is approximately 750 gallons. The tank was sized in order to get the required additional septic tank capacity and to cycle the pump operation of the system. The pumping system is required to pump the effluent up approximately 8 -feet of elevation difference and 15 -feet of piping and head losses, for a total of 23 -feet of head at 90 gpm. The pump we have chosen for the system is a submersible, by Hydromatic Pump, Model number SK -75, a bronze pump system, with a piggyback float system. The pump is a.75 horse power, single phase, 115Volt unit, with a 2 -inch discharge and a built in diaphragm level control system or optional float system to regulate the operation of the pump based on water levels in the tank. The existing pumps are not sized correctly to be allow them to be reused. The pump operation and installation is simple, as the water level in the tank rises it switches on the pump, which operates until it reaches the bottom of the pump and shuts the pump off. We recommend the operational float level system for the tank. A double float system will need to be used, also by Hydromatic, Model 3900. The pump is to set on the floor of the tank approximately 6 -inch above the floor. (Design details for operational water levels in the tank are to be field determined by the design engineer. The type of pump control depends on the dimensions of the tank). Please check to see if the existing tanks controls meet these recommendations, if they do, they can be reused with the new tanks, again check with the contractor installing the system. The pump operates at a approximately flow rate of 90 gallons per minute at the required 23 -feet head, and pumps the effluent up to the manifold just prior to the distribution laterals. The manifold distributes the flow into the laterals. The flow is evenly divided into the 6 lateral piping systems, with 1/4 -inch holes at 36 -inch centers. Additional information on the selected pump is enclosed for your review and use. At your option a second pump could be purchased as a backup or stand by pump. This would shorten the system down time and inconveniences which will occur if the pump breaks down or has other problems. The cost of the second pump is approximately $900.00. It is not required, but is recommended. The effluent tank is also required by the County to be equipped with a high water level alarm system to alert you when a pump has failed to operate or another problem has risen. The high water level alarm system is operated by a float, mounted on the tank wall, which is activated when the water level rises to a chosen point above the normal operating pump level. The float signals a red light and a buzzer, which should be located in your adjacent mechanical room or garage. The buzzer can be turned off manually signaling acknowledgment of the problem, but the red light stays on until after the water level drops back down. This is a required safety feature which assists the owner in the satisfactory operation of system by letting you know you have a problem before it becomes an emergency situation. The system we have chosen is a Tank Alert 1. by S.J. Electro. (See design drawing for additional level control details. Please check to see if the existing alarm can be reused. 2 - 2 -inch PVC conduits are required to be run from the adjacent home to the new effluent pumping tank. One is for power to the pump and the other one for the high water level control system. Please inform the electrical designer of the home of these additions. Installation and Materials: The septic tanks can be obtained from Copeland concrete products in Rifle, or from the locally in Emma from Dreager. The tanks should be located as shown on the drawings and installed level. The access ports are to be sealed water tight and brought up to within 6 -inches of final grade. If in the event the tanks are too high, minor landscaping may be required to bury them. The invert elevations for both tanks are critical to the operation of the Pump and should be followed closely. The blockouts for the inlets and outlets are also required to sealed water tight to prevent infiltration. All piping, pump, and alarm system materials can be obtained form Dodson Engineering products in Glenwood or Grand Junction Pipe in Basalt. The 4 -inch piping from the house to the septic tank and to the pumping tank is SDR 35. All manifold, distribution, and lateral piping is to be Schedule 40 PVC. All Piping should be installed at a minimum depth of 3.5 -feet. The pumping line is to be laid with the shown slope to permit the line to drain back into the tank after each pumping cycle to prevent freezing. The laterals are to be installed as shown on the drawing and are need to be installed to within + or - .01 -feet. (See attached design drawing for bedding details and additional installation notes.) The septic system installation can be done by any excavation contractor who is familiar with this type of project. If you have any questions on the design or other items, please feel free to call me at any time. See installation and construction notes attached to this memorandum. CC: CCA - MWE - Denver PCEH - Nancy M. Thanks, Dean Derosier ! 24 10 TypicalApplication* Sewo e, Dewatering Capacities to 150 GPM (9.5 Vs) Heads to 34 ft (10.4 m) Electrical 20OV, le, 10.4F(A, 60Hz; 230V, le, 9.OFLA, 60Hz 20OV, 3a, 4.OFLA, 60 Hz, 230V, 3e, 3.5FLA, 60Hz; 460V, 3e,1.8FLA, 60Hz, 575V, 3e,1.44FIA, 60Hz Motor (single phase) - 3/4HP Capacitor start w/thermal overload protection, 3450 RPM; (three phase) - 3/4HP polyphase, Minimum Recommended 3450 RPM Minimum Recommended Simplex = 24" (609.6mm); Sump Diameter Duplex = 36" (914.4mm) Operation Manual standard; Optional - wide anile float switch 1 ! Materials of construction (lass 30 cast iron Impeller (lass 30 cast iron two vane non -dog Discharge Size 2" (50.8mm); 3" (76.2mm) optional Solids handling 2" (50.8mm) Power cord 1 e, 20', S(W-A; 3e - 20', SPH -A Superior Features • (arbon/Ceromic type 21 mechanical seal • Oil filled motor w/automatic reset thermal overload for maximum protection • Upper and lower single row ball bearing construction • Capacitor start motor for improved starting!r..tue and pump performance 12 4 9 30 LwLw 6 20 a 0 3 ~10 0L 0L Capacity -U.S. G.P.M. Liters/Second 0 Typical Application* 11 Sewage, Dewaterin (opacities to 156 GPM (9.8 Vs) Heads to 38 ft (11.6 m) Fledrical 20OV,lo, 11.5FIA, 60Hz; 230V, le, lO.OFLA, 60Hz 200V, 3e, 5.OFLA, 60 Hz; 230V, 3e, 4AFLA, 60Hz; 460V, 3e, 2.2F(A, 60Hz; 575V, 3e, 1.7FLA, 60Hz_ Motor (single phase) -1 HP Capacitor start w/thermal overload protection, 3450 RPM; (three phase) -1HP polyphase, 3450 RPM Minimum Recommended Simplex = 24" (609.6mm); Sump Diameter Duplex = 36" (914.4mm) Operation Manual standard; Optional - wide angle float switch Materials of construction Class 30 cast iron Impeller Class 30 cast iron two vane non -dog Disc are Size 2" (50.8mm); 3" (76.2mm) optional Solids handling 2" (50.8mm) Power cord le, 20', S1W-A; 3e - 20', STW-A Superior Features • Carbon/Ceromic type 21 mechanical seal • Oil filled motor w/automatic reset thermal overload for maximum protection • Upper and lower single row ball bearing construction • Capacitor start motor for improved starting torque and pump performance SKI 20 40 60 80 100 120 140 160 4 +- 2 4 6 8 10 I i'-" IV" AREA :.CALCULATION S SUMMARY LIVING AREA CALCULATIONS A Area.; ....' Name of Area Slze Totals TABLE ADDENDUM Breakdown Y SKETCH/AREA He NO: 4229 Borrower/Client Mahaf£'Geo1,cue J. Arid ,7amta P. u VI Al Ylrnt. Vla r 2427.62 2427.62 8 Property Address X 43.60 1495.48 271 Little E 1.1, Creek ,?iVE'rme j City(`nunty State 7Jp Code G Snowmass Pi Lki._n C.,o1c,7_adc� 81654 22.20 X 32.20 714.84 .f. Lender FirstWestern Lending of As en _ AREA :.CALCULATION S SUMMARY LIVING AREA CALCULATIONS A Area.; ....' Name of Area Slze Totals Breakdown Subtotals VI Al Ylrnt. Vla r 2427.62 2427.62 34.30 X 43.60 1495.48 GLA2 Loft 289.00 288.00 22.20 X 32.20 714.84 GAR Garage 457.20 491.20 4.00 X 32.20 128.80 c 12.30 X 5.00 61.50 AS. 0.30 - X 11.00. .1 J '. 1.90 x 3.00 5.70 C 6.00 X 3.00 18.00 u 6.00 X 16.00 96.00 6.OU X 12.00 72.00 A ' 10.00 X 12.00 120.00 T I O N S TQTAL LIVABLE (rounded) 27'16 27`16 MO EN REAL ESTATE APPMSENS, LTD. APEX SOF WAAE, INC. 1 (512) 699 66813 Form nex2000 w �n ORIGINAL SURVEY ALPINE &URvE` ,^- F 0 BOX 1730 ASPEN CO, 81612 970-925-2688 DANIEL MCKENZ IE 6/3/88 T,4Ni<, f=Jt- f= 4ND REUSE DISCONNECT OLD 5STE1„1 4ND RECONNECT TO NEW L INE TO NEW T,4Nf< f T,4N<, r-14TCI-1 IE OUTV�,T,4LL OF EX IST ING T,4Nf< NEW 4'' SDR3 PVC FROr-1 EX IST INCA T,4 << TO NEW T,4N< ,4NIDF NEU 11,000 G,4L T.,4N< TO D S C� T4N< 20 0 20 40 inch = 20 feet i"10UND S"'STEI-i OYER,4LL DE1" TENS IONS 4RE 80' X 57' 6,4ND 5T'STEr'1 50' x 24', SEE DUJG T�4 IS SHEET FOR DET,41LS OF i"IOUND S`►'STE�* 1 1" 1OUND 15'T'&TE1�1 15 12 1'' SCS .40 FVC, L,4TER4,LS 22' IN LENGTH, 3' 4P,4RT 4ND 4,5' FROI" 1 SIDES, 1/4" MOLES aro OO r4T SOTTO - 1 OF RIFE, EXISTING SYSTEM TO REt' 1,41N IN PL4CE, DISCONNECT LINES FROl"l T4N<, LOC,4T ION IS UN<NOUJN ALL 3'' 1"T,4N IFOLD ,4ND TR,4NS1„1 ISS 1ON FRO -1 DOS INCA T,4Nf< TO FIELD ,4ND 4CN L,4TER,4L LINE IN 1" FOUND S''&TE1 l :�E L INE TO DRA IN 5,4Cf< TO TANf< �,5 FOOT COVER, T" G4N IFOLD IN CENTER OF T IOUND . NEW 750 GAL DOS INCA T,4Nf< SEE 4TT,4Cl4ED DLJG FOR DET,4ILS IE TO 5E FIELD DETERI''T INED 5,4SED ON EXISTING T,4Ni<, D = 2.75' 6 ROWS EACH SIDE (22' LONG ) OF I" PERF PIPE 1/4" HOLE ® 60" OC, 3' APART E = 2.75' PERFORATED PIPE F = 0.75' CLAY FILL OR G = 1.0'-��-_I I !_� I OTHER FILL H = 1.5' SUBSOIL --I0.5% SLOPE A = 24' B = 50' W = 57' L = 80' 1 = 19.5' J = 13.5' K = 15' 3/4" ROCK ROCK PLOWED SURFACE MOUND DETAILS CROSS SECTION — NTS W SOIL 2-1/2" MANIFOLD FROM TANK 3/4" SCREENED ROCK MEDIUM SAND FILL CLAY OR OTHER FILL MOUND DETAILS PLAN VIEW DOSING TANK ING TANK LEVELS 0 SBE FIELD DETERMINED NTS BY THE ENGINEER K t A J J ETAN DISTRIBUTION LATERAL BED 3/4" SLOPE i - m OF ROCK SLOPE MOUND DETAILS PLAN VIEW DOSING TANK ING TANK LEVELS 0 SBE FIELD DETERMINED NTS BY THE ENGINEER