Loading...
HomeMy WebLinkAboutpitkin.eh.264504303014 (1992)ASPEN40PITKIN ,9)49g5- oq3 03-d/ y ENVIRG..dMENTAL HEALTH DEPART..AENT INDIVIDUAL SEWAGE DISPOSAL PERMIT NO.�i/_�/ TYPE OF PERMIT: (Initial Construction ( )Emergency Use ( )Repair Work,(Pievious Permit 1 .) ( )Alteration of an existing system, r installation (Previous Permit 1 j ( )Use Permit as a result of sale ( )Others ISSUED TO: DATE OF ISSUE. Z1_6 117Z-" Owner Mailing Address Home Phone Business Phone ME L . e -57 Agent! Phone S�'.� �}r Mailing Address Sewage Disposal System Work to be performed byEj/1!iFE/S This permit valid only for premises location by the following legal descriptions _'zr &) LOT SIZE ..} /-i MC ls� . WATER SUPPLY2V6D1V1'31 nI U) f_1_ . "ERACE PERCOLATION RATE ,/ This Individual Sewage Disposal Permit is granted with regard to the following uses /1% C 14ONC�r✓'r&f I FSJ d Nutaber oft Dodreoms . Lofts Garbage Disposals Dishwashers^ Clothes Washors r'7 CALCULATED AVERAGE DAILY WASTE LOAD � � GALLONS. THE NATUIRE OF THE SYSTEM INCLUDED UNDER THIS PERMIT: ape of Tank or Treatment Units "�ANK / Tank.Capacit t06 Callon Minimum Ahod of Final Disposalt F,�1,4JCej"[-0(i1//5�Q/1/S//1%Ll�(i/)0�eorptiotl Area �7Y A square Fent/Minimum r� _.crl ion (including brand name, if any) of other equipment or appurtnancest '� �' ` WN C� 64v CrfAl� 6�IJ n g /g0L)A),O W I %f b' 6A S19 OF 230L/ P F7-.. :they Condition! or Spccificationes �ry A>v� ``'C6`/G10/QT/v�t1S lAI /� j --a /�,y �ar�iJ�/2 . �-N�/NSP-lnlG, ATEA � Y1� �8t'"�3z cr¢u�Et�. �� Osl_ o 4 c /1 STAGES REQUIRING INSPECTION BY THE HEALTH DEPARTMENT: �/ ( )Before Excavation ( )Upon completion of excavation and prior to placement of gravel X�tHysten offore vering istiutio absorptionrfield n (Prior to backfill of any component ( iother, Specifys Plans and specifications of the proposed sewage disposal system have been reviewed and are considered satisfactory. Permission ix hereby granted to the owner or his anent to performthe work indicated above in accordance with the Pitkin County Indivi3ual Sews -p! Uispcsai Rc,iulations in effect on the date of issue. In addition to general provisions Oct forth or, the reverse her•�oi, this Permit is subject to the following additional terms and conditions: APPROVED FOR ISSUE BY (title) �f1�1 Tho bo ave individual sevago disposal system installed by VVr �/V�r-I �' "e( I r'"' has b' -en in:,pected for use by a representative of the Aspen iPit�Lnvlr-n—,n }iea C.. Dcp.�rtmtnt, Tho,,,rout as�,u—'tea arl rc:;Ponslbiltty in c,:se of failure or inadequacy of ttlis :sewage disposal system. Complete as -built drawing ettached. DATE O1 NAL IISPECTI N 2 _ BY: TITLE 130 South Galena Street Aspen, Colorado 81611 303/S20-5070 ASPEN*PITKIN '' ENVIRMMENTAL HEALTH OEPARTtd1ENT APPLICATION FOR AN INDIVIDUAL SEWAGE DISPOSAL•PERMIT Name of OWNER A I W l k'T 7— PHONE Address of OWNER y^L. LI 0 Name of APPLICANT Lim CSL PHONE RT TO BE. (/ Picked Up ( )Mailed tot TYPE OF PERMIT. ( )New Installation ( )Repair PERMIT ( )Owner ( )Applicant ( )Emergency Use ( )Alteration NOT due to failure LOCATION OF PROPOSED SYSTEMt Legal Description / —t Lot Block ' Filing Subdivision G% /�- L—.L< C ize of Lot �.. _ acres 44 SLngle Family Dwelling ( )Other: re; Do you plan any further additions to the TYPE'OF STRUCTURE: residence? ( )YES NO / No. o! bedrooms �' No. of Lofts-_ No, of Garbage Disposals [ No: of Automatic Dishwashers No. of Automatic Clothes washers MATER SUPPLY: '".Private Well, Depth or ( )Public, Name of System ( )Spring ( )Stream or Creek TYPES OF INDIVIDUAL SEWAGE DISPOSAL SYSTEM PROPOSED: 77Nseptic Tank/Absorption Field ( )Aeration Plant/Absorption Field ( )Composting Toilet ( )Ineratlon Toilet ( )Mound (*)Recycling, potable use ( )Recycling, other use ( )Vault Privy t )Other: The initial site inspection must be arranged with the Aspen/Pitkin Environmental Health Department (925-2020. 8:30-9:30 a.m.) before a permit can be issued. The individual sewage disposal permit must be issued before a building permit can be obtained. FINAL INSPECTION APPROVAL MUST BE GIVEN BY THE ASPEN/PITKIN ENVIRONMENTAL HEALTH DEPARTMENT PRIOR TO BACKFILLING ANY PORTION OF THE SYSTEM. Application for an individual sewage disposal permit is hereby submitted. The undersigned acknowledges that the above information is true and that false informatiowill invali to the application and any subsequent perms , DATE Signature of Applicant his application becomes. invalid 12 months from the above date.) NOTE: PLOT PLAN must be filed with this application. Please locate the following items by measured distances: 1. Property lines and dimensions. 2. Proposed and existing water wells on subject property and adjacent property. 3. Domestic water service lines. 4. Proposed and existing buildings, driveways, and other Structures. S. Streams, lakes, ponds, irrigation ditches, and other water courses. 6. Proposed and existing individual sewage systems on subject property. SUBMIT A REVISED PLOT PLAN PRIOR TO CONSTRUCTION IF INSTALLATION IS TO BE CHANGED FROM ORIGINAL PLAN. The undersign hereby acknowledges receipt of this individual sewage disposal permit application and a permit fee in the amour. 'v7,Jl1, , Receipt Number ICAO , Date Fee Received �� r / r� • by of S —T'r Admin strativo Officer 130 South Galena Street Aspen, Colorado 81611 303/920-5070 High Country Engineering, Inc. 923 Cooper Avenue Glenwood Springs, CO 81601 303-945-8676 • FAX 303-945-2555 TO�'I l 1 NTi (� N ATTN We are sending the following: �erewith ❑ Photocopies Prints ❑ Documents � JUN 3 0 1992 ENVIRONMENTAL HEALTH ASPEWPITKIN DATE (�e/30 // �- SUBJECT 10 BLk f r1L' / JOB NO. ❑ Under separate cover ❑ Mylars ❑ Shop Drawings NO. OF COPIES ITEM LATEST ITEM DATED REMARKS vt L� If material received is not listed above, kindly notify us at once. Transmitted by: ❑ First class mail ❑ U.P.S. Next Day Air ❑ Federal Express ❑ U.S. Express Mail ❑ U.P.S. Std. Service Messenger ❑ _Pickup 0 FAX El By: July 24, 1992 Mr. Bob Nelson Pitkin County Environmental Health 130 S. Galena Aspen, Colorado 81611 E !� JUL 2 7 1992 ENVIRONMENTAL HEALTH e4SPEN/PITKIN Re: Wirtz Residence Lot 10, Block 1, Filing I, Little Elk Creek Subdivision HCE File No. 92004.12 Dear Bob: On July 7, 1992, High Country Engineering, Inc. personnel observed the visible construction of the individual sewage disposal system at the Wirtz residence. The construction appeared to be in conformance with the intent of the design. If you have any questions or need additional information, please give us a call. Sincerely, HIGH COUNTRY ENGINEERING, INC. Tim thy P. Beck, P.E. Prin ipal Engineer TPB:cso cc: Larry Leeper 923 Cooper Avenue • Glenwood Springs, CO 81601 Telephone: 303-945-8676 - FAX: 303-945-2555 �j� �+ �� ,/� �- l � IVV" � D �� to � o ` V" 0 � �� �, � 1 t �� � ,'J/ LOT 4 294.00' -�� IRRIGATION DITCH �A<,s ,l J 25' MIN. TOE OF MOUND �` r `�_ ��f o t/' / 1000 GAL. CON C. GRAVEL BED DOSING TANK05 ;, , �� .33 4 3' ��, r i �� 1�:' • ��. �^ , • w j 1000 GAL. CONC. SEPTIC TANK � > ('� ;. �Q 1 �.,i=�' �� � 1 jsn� i i` C 'lam711 LOT 10 Wlt_�_^ GRAPHIC SCALE \ ;'\� i. ecvlllz 20 ° 10 20 ,o z�; r Q ; ;I L�� sir-- u� ( IN FEET) _--_T-Ln HOUSE 1 inch - 20 ft. o° �...- 111 a �� %• � ". J" j �,, . , .� I ��w% .�.� ok VICINITY MAP �qY SCALE: 1' 2000' 307.00' LOT 11 SITE PLAN TOE OF MOUND SLOPE t GENERAL NOTES 64't 1. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE PITKIN COUNTY A REGULATIONS OF INDIVIDUAL SEWAGE DISPOSAL SYSTEMS, EVEN THOUGH ALL SUCH REQUIREMENTS ARE NOT SPECIFICALLY NOTED ON THE DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SUCH SPECIFIC DETAILS AS ARE REFERRED TO IN THE ABOVE MENTIONED REGULATIONS. 40.0' .n FILTER FABRIC 1.5 1.5' 2. 2 BEDROOMS 300 GALLONS/DAY AVERAGE TOPSOIL450 BED OF 1 1/2" SCREENED GALLONS/DAY MAXIMUM 1000 GALLON SEPTIC TANK SLOPE DROPO ROCK, 12" THICK o ++ 475 SQUARE FOOT MINIMUM GRAVEL BASE AREA 12"� MIN. / / // / // / / / _� M GGALLLONFOOT TANK.SAND BASE AREA 6000SQUARE DOSINGMINIMUM \i\�\�\�\�\�\�\�\�\�\ 3 S. PUMP: 25-50 GPM @ 35 FT. HEAD EXISTING GROUND\ 3 �� /. o M u) 3. SAND FILL SHALL MEET THE FOLLOWING CRITERIA: \\ EDGE OF SCREENED ROCK BED 100% SHALL PASS THE #4 SIEVE (6. 4 MM) . <10% SHALL PASS THE #200 SIEVE 0.13 MM AND SHALL HAVE A UNIFORMITY COEFFICIENT LESS THAN 5 (D60/D10<5). CONCRETE SAND AND MASONRY SAND WILL BOTH GENERALLY MEET THESE DISTRIBUTION LATERALS 24" MIN. SAND A \_ 1-1 PERFORATED PVC CRITERIA. SCREENED SAND MAY ALSO BE ACCEPTABLE; SUBMIT SAMPLE TO ENGINEER. SAND FILL - SEE NOTES THICKNESS 2" SOLID PVC FROM DISTRIBUTION DOSING TANK LATERAL FOR MINIMUM BASE AREA 4. CLEANOUTS ARE REQUIRED AT ALL BENDS AND AT LEAST EVERY 100 FEET ALONG THE HOUSE SEWER UP TO THE SEPTIC TANK. SECTION A-A PLAN VIEW OF MOUND 5 RINSTALLING THE ALL LSYSTEM L BE EPRIOR IBTOE COMPONENTTSCOFRTHIS THE ABSORPTION AREA WATER 4' X 4' N.T.S. N.T.S. TIGHT TO PREVENT] NF I LTRAT I ON. TREATED POST 6. TOPSOIL COVER MAY BE VARIED (WITH 1 FOOT MINIMUM) TO ALLOW LANDSCAPING. ELEC, JCT, BOX 2' AIR VE��T 7. INSTALL RISERS AS NECESSARY TO BRING ALL ACCESS POINTS TO WITHIN ONE-HALF FOOT OF FINAL GRADE. RISER(S) TO GROUND SURFACE 8. LOCATIONS OF ALL COMPONENTS MAY BE VARIED AS NECESSARY AS LONG AS ALL MINIMUM DISTANCES AND SLOPES MEET THOSE REQUIRED. CAULK/SEAL 9. LOT DIMENSIONS AND TOPOGRAPHY PROVIDED BY OWNER. INLET 10. PROVIDE POSITIVE DRAINAGE OF SURFACE WATER AWAY FROM MOUND FILL AREA USING DRAINAGE SWALES AS NECESSARY. DRILL 1/4'0 HOLES 30" ON CENTER FOR ENTIRE z 2' FEEDER '_INE TO LENGTH OF ALL LATERALS 1-1/2' PVC LATERALS MOUND, SLOPED AT `?E-N/ FlTKtN 1/8` PER F"", MIN, N .. 15 15 �- £,> z O � hkENTAL HEALTH 'ALARM' QUICK DISCONNECT OR UNION " E 2 PVC MANIFOLD (SOLID) �• PI( ) s�opf NOTE:_ A. ALL PIPING MUST DRAIN '❑N' BACK TO DOSING TANK ARPROVED' a_ COIL AND TIE AN ADDITIONAL 10' OF 5LOPE iv WEIGHT WIRE FOR PUMP REMOVAL HOLES ON BOTTOM OF LATERAL OFF S34 00 0 0 SLOPE N0. DATE REVISION I BY NOTES: LARRY LEEPER 1. SWITCHES TO BE MERCURY TYPE. PITKIN COUNTY, COLORADO 2. FLOAT SWITCH DIMENSIONS ARE BASED ON A COPELAND 1000 GAL. TALK. (CISTERN) 2" SOLID PVC FROM INDMDUAL SEWAGE DISPOSAL SYSTEM ,- 3. DOSING TANK SHALL BE OF WATERTIGHT CONSTRUCTION. DOSING TANK LOT 10, BLOCK 1, FILING 1 LITTLE ELK CREEK SU B D DOSING TANK ARRANGEMENT PIPE LATERAL LAYOUT FM , wc. . =COUS9AVBVlJE N.T.S. GLI NWOOD 8PF&M Co 81601 DES. TPB CK. FILE N0. SHEET , N.T.S. \12LEEPER (3OGS) 945-8676 DR. HMS DATE 6/29/92 92004.12 OF 1