Loading...
HomeMy WebLinkAboutpitkin.eh.264309300013 (1991)ASPEN*PITKIN ENVIRONMENTAL HEALTH DEPARTMENT INDIVIDUAL SEWAGE DISPOSAL PER11IT NO. q^ oo1� TYPE OF PERMIT: ( )Initial Construction ( )Emergency Use ( )Repair work,(Pievious Permit 1.) XvArevious lteration of anexticor installation Permit 1M1*�.) ( )Use Permit as a result of Sala ( )Others ISSUED TO: DATE OF ISSUE. �� 1 Owner dJ04<L & Home Mailing C n ��/ Address /U CI TC PC 11) `iFU(J/+� Azri� 7� A ;en tJ ( Ma il.in g Address VC -4 — 1-it,T1 an! Phone Business Phone q2,_57 -J -//1V Phone 913 -2V67 267 Sewage Disposal System Work to be performed by This permit valid only for premises location by the following legal descriptions �;4� LOT SIZE -9 Aeas • WATER SUPPLY LsC�- , AVERAGE PERCOLATION RATE 0 This Individual Sewage Dispos 1 Permit is granted with regard to the following use: _'+y L' - E� a)ck Nuraher of: Dodreoms Lofts Garbage Disposals 2— Dishwashers— Clothes Washers 7 CALCULATED AVERAGE DAILY WASTE LOAD GALLONS. THE NATUtE OF THE SYSTEM INCLUDED UNDER THIS PERMIT: ype of Tank or Treatment Units ,PT/ti I/T � d Tank.Capacity °��� Gallon Minimu:a athod of Final DisposalsA�.)�pPPOtJ- i?--C—Al"0!►bsorptiop Urea 2 -0 -lb Square Peet Minimum ,,DJescription (including brand name, if �Y any) of other equipment or appurtnancess 1 wmii;- =SL LIFT PCC)M P /J /(-16 0 GALce),i ?,4104 4eloK 7,r, -7P1_sdz14Ac-.E TD )ther Conditions or spec ficationesft5q �1/1i1�/ PL�� j p!s'�.i0dr�tJ P)Pis AID i�if�//T0 $0 F670r ore W) iJO� of s* __rA Ali -I "191e 14 15 1*111 AA06 6,_0 770 /moi /12-11"111Fn - . b -M0 v16 -V 'D 0,01A/C 1992 96111oD61- STAGES REQUIRING INSPECTION BY THE HEALTH DEPARTMENT: { )Before ExcavationUpon completion of excavation and prior to p{aCement of gravel ( Before covering distribution ,` system of absorption field Prior to backfill of any component ( iOther, Specifyt Plans and specifications of the proposed sewage disposal system have been reviewed and are considered satisfactory. Pernissi.on is hereby grao.ted to the owner or his agent to perform the work indicated above in accordance with the Pitkin County Indivi ual Sewa;e Disposal Renulations in effect on the date of issue. In addition to general provisions set forth on the reverse her -of, this Permit is subject to the following additional terms and conditions: APPROVED FOR ISSUE BY�� (title) Thc• ahive in4ividual set..a90 disposal system installed bys[t/C�/�L'? /C- �/4/f"J/ has lien ln:pcctcd for use by a representative of the As en Yit7 to in lronrwnta rcaponsibillty in c43c of failure or inadequacy of th u sc aye disposal system. !�' G DATE 0 ' N ITiSp CTI N BY Aspen/Pitkin Environmental Health Officer Rca)th Departinent. The ownor A"Iwr,os a Complete as -built drawing attached. TITLE 130 South Galena Street Aspen, Colorado 81611 Aspen/Pitkin Environmental Health Officer 303/920-5070 a>R ASPEN#PITKIN ENVIRONMENTAL HEALTH DEPARTMENT APPLICATION FOR AN INDIVIDUAL SEWAGE DISPOSAL -PERMIT Name o f OWNER ala � . PHONE Address of OWNER Name of APPLICANT ,.ERMt! T TO BE: Picked Up ( )Mailed toe . ( )owner ( )Applicant TYPE OF PERMIT: ( )New Installation ( )Repair 1 )Emergency Use WAlteration NOT due to failure W-ATION OF PROPOSED SYSTEM: Legal Description Got Block Filing Subdivision Size of Lot acres I P1fP£'OF STRUCTURE: VSingle Family Dwelling ( )Other: Do you plan any further additions to the residence? P14 If ( )NO No. of bedrooms_ No. of Lofts No. of Garbage Disposals No: of Automatic Dishwashers o _^ No. of Automatic Clothes Washers dATER SUPPLY: ( Private Well, Depth ((1 or ( )Public, Name of System ( )Spring ( )Stream or Creek TYPES OF INDIVIDUAL SEWArE DISPOSAL SYSTEM PROPOSED: Septic Tank/Absorption Field ( )Aeration Plant/Absorption Field ( )Composting Toilet ( )Incineration Toilet ( )Mound ( )Recycling, potable use ( )Recycling, other use ( )Vault Privy ( )Other: The'initial site inspection must be arranged with the Aspen/Pitkin Environmental Health Department (925-2020. 8:30-9:30 a.m.) before a permit can be issued. The individual sewage disposal permit must be issued before a building permit can be obtained. FINAL INSPECTION APPROVAL MUST BE GIVEN BY THE ASPEN/PITKIN ENVIRONMENTAL HEALTH DEPARTMENT PRIOR TO BACKFILLING ANY PORTION OF THE SYSTEM. Application for an individual sewage disposal permit is hereby submitted. The undersigned acknowledges that the above information Is true and that false inf atio will invalidate the application and any subsequent permit. Signature of Applicant DATE �0 '// (This application becomes. invalid 12 months from the above date.) NOTE: PLOT PLAN must be filed with this application. Please locate the following items by measured distances: 1. Property lines and dimensions. 2. Proposed and existing water wells on subject property and adjacent property. 3. Domestic water service lines. 4. Proposed and existing buildings, driveways, and other structures. S. Streams, lakes, ponds, irrigation ditches, and other water courses. 6. Proposed and existing individual sewage systems on subject property. SUBMIT A REVISED PLOT PLAN PRIOR TO CONSTRUCTION IF INSTALLATION IS TO BE CHANGED FRO14 ORIGINAL PLAN. The undersigned Hereby acknowledges receipt of this individual sewage disposal permiy appl cation and apermi e n the anourt of i 20 , Receipt Number W , Date Fee Received •by Administrative Officer 130 South Galena Street Aspen, Colorado 81611 303/920-5070 13 7- l3 /a a PLACE FILTER FABRIC - M/RAF1140N OR EQUAL ABOVE ROCK SEE NOTE 1#14 E.XI�TING Z�S�CPE �0?�. t3.. OF TO GRADE �\ 5 CL EAN ROCK ROUGHEN SURFACE _ BEFORE PLACING SAND END CAP (T YP.) 24 — ----i-- — -- -- -----i—- --- —� — I ; R, Ch f i1_ L ^` li L P L Cl,Yf- R 2" SCK 40 PVC PIPE SLOPE 70 DRAIN SACK TO DOSING TANK DEPTH MA'r' t A R ` CSI ENDING OIJ DEPTH OF LxISlAVC TCr,:50'L, ''.LL TOr C'iL. ,ut.45 7 hF R�.V;; SFC TION A -A l" CLASS 200 PVC LATERALS (TYP.) "HOLES LOCATED DOWNWARD SPE - 2"x2' x1. REQ•OJ , 5�� 40 D SINE 2' �ANIFOL 2" TEE (4 RECD D) 2 90' F1TTING BUSH DOWN (2 REO D) 45 ° BEND 2" SCH. 40 PVC PIPE' SLOPE TO DRAIN BACK TO DOS/NG TANK YFICA L L A TER,4 L INS TA LA TION DE TAIL N T.S. I Ll NEUTRAL L2 115 A 115 Yo" Ydb 15 AMP CIRCUIT 5 A,�P CIRCUIT BREAKER fOR O BRE.1AER FOR PUMP ALARM . #16-P CONDUCTOR CORD TO FLCA ALARM CONTROL UNDERGROUND BURIED CABLE EITHER ROUND OR FLAT SJ ELECTRO MODEL WIDE ANGLE PIGGY ✓Br0-5 PVC B(JK ` BACK , T SWITCH ALARM BOX LOCATED IIII /N HOUSE t*'14-2 CONDUCTOR CABLE W1 GROUND WIRE / USE ,/'l2 -P CONDUCTOR W1 GROUND IF OVER 60' X0'/6-3 CONDUCTOR A. CORD TO PUMP STRAIN REL EIF � A14-2 CONDUCTOR CABLE FOR ALARM CONTROL r 70 ALARM FLCl47- wlR11vG TO CIRCUIT BREAKER PANEL WIRING CONNECTIONS FOR AL ARM BOX 8 AWS -1 LEVEL CONTROL _T_ �- USE l " SCH. BO PLC 1 ` UNDERGROUND CABLES FOR ALLOW EXTRA CABLE ON FOW£R PIPE B FITTINGS f -OR ► j j PUMP 8 ALARM CONTROL B ALARM CABLES TO REMOVE PUMP PUMP 8 PIPING IN TANK _ ALARM AND 8 PIPING W/O DISCONNECT-ING WIRING CUNNECTAOIV BCX 20" DIA. RISER PIPE FOR PUMPING TANK P9" D/A. RISER PIPE 2" SCK 40 PVC PIPE PVC SLOPE 4 "/F T. M/N.O70 MOUND. SLOPERA/Q4CK R7 T4NK q 134 FFL E —-----�----� _ WASTE L/fJE FROM HOUSE 4" PLC CONNECTS TO HOUSE VENT SOLID GMUND SYS TEM 5 " MIN 1250 GAL. CONC, Cl PIPE PUMP ON DRILL' DIA. HOLE SEPTA: TANK BETWEEN IN 80T 70M OF PIPE TANKS 8 GROUT EXISTING HOUSE HOLE TANK AL ERT 11 PL US SYSTEM FLOAT (BY Puw OFF "1 SJ ELECTRO S )S 7 EMS) i ? 1 _ S W33 LATER /N SUB- — � �UMPIBLE (BY FFLUENr IC) iYDROMA7 1000 GALLON CONC. SEPTIC i B" CONCRETE BLOCK TANK USED fDR DOSING TANK .INSTALL 4" DIA. NCI£ ___-- 8" ABOVE TANK BOTTOM T YPICAL ll!lS TA LA TION OF TAl1/KS,PUMi' 8 COIV TROL S 4 PV - 4 s� PL U6 f CL E,4 N- CUT DF TAIL LnSCHMUESER GORDON MEYER INC. ENGINEERS & SURVEYORS S IUA 1512 GRAND AVENUE SUITE 212 GLENWOOD SPRINGS, COLORADO 81601 (303) 945 - 1004 REVISIONS COATES RESIDENCE P/TKIN COUNTY NO. DESCRIPTION DATE BY CHKD. IMS COLORADO SE WA GE DISPOSA L SYSTEM JOB NO. DATE SCALE APPR. BY W 9174 1 II -I--89 1 RC I NOTED I JSS 1 2 of 2 0 50' MOUND 0.+ 2•Z o \ TYP. "A \ ' 6 f -A- L A TERA L LATERAL PIP/NG SEE DETAIL DWG, No. 2\ 6' .+- \ 2„ SCH. 40P / \ \ \ \ �/- \ \ \ \ \ \ \\ \ \ \ \ 1 PVC SEWER PIE I \ 1000 N� T NK p0S / ONC \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ EXIS TING \ GAL. C \ \ \ \ \ \ RESIDENCE \ \ 4” SCH• 40 -�, 1250 TIG ANK \` \ \ \ \ \ \ \ \ \ PVC SEWER PIPE \ SEP o 7D I I \ \ \ \ \ \ \ \ 1 r ' CLEAN-OUT SEE DETAIL DWG. No, - PROPQSED \ \ \ \ \ \ \ \ \ \ \ \ � • • RFS10117 \ \\ \ \ \ \ \ X Tom •\ � � \ � \� � \ � \ � \ � � � C'E QF 2'PINE \ W''4TER \ _ 2' SPRUCE \ S1 TE NOTE: PLAN SCALE: /" = 20' SEWAGE DISPOSAL SYSTEM /S SHOWN /N SCHEMATIC. ABSORPTION BED, SEPTIC TANK, PIPING ETC. MAY BE RELOCATED TO F/ T THE LANDSCAPE AS LONG AS MINIMUM SETBACK CLEARANCES ARE MAINTAINED. ... • • � �....„•nay • a.r— .. \ E 1 k t .� • _'vim= 1, A11 materials, installation practices, setbacks, etc. shall conform to Pitkin County Individual Sewage System Regulations. 2. On Feeder, Manifold and Lateral Lines, provide sufficient slope towards their inlets to allow the piping to drain. 3. Sand shall be medium texture sand. > 25% 0.25 - 2.0 ?tun < 30-35% 0.05 - 0. 25mm > 5-10% 0.002 - 0.05 mm The Engineer may require that a gradation analysis be performed to certify that the material proposed meets this specification. 4. The Contractor and Owner shall take whatever measures are necessary to assure that (a) the dosing tank, septic tank and sewer lines are completely water -tight to prevent infiltration of groundwater into the system, and (b) the system is to be installed to prevent freez- ing of all pressure and gravity sewer lines. 5. The County Environmental Health Department shall be notified when construction commences so that the system can be inspected at regu- lar intervals to assure conformance with these plans. 6. If the last hole, based on 30" spacing, is equal to or greater than 15 inches from the end of the lateral, put another hole in the end cap of the pipe or close to it. 7. Stone shall be 3/4" - 2-1/2" crushed rock. 8. The amount of fill outside of the sand area may vary from what is shown in Section A -A to allow the homeowner to blend the mound in with the Landscaping Plan. 9. The area disturbed by construction shall be reseeded with native grasses to prevent erosion. 10. Use risers as needed to bring septic tank access hatch within 6" of finished grade. (Bring dosing tank access hatch to grade). 11. Cast iron pipe or pipe of equal strength or other pipe properly supported to prevent failure by settling shall extend from septic and dosing tanks for a distance of at least five (5) feet from the inlet and outlet ends. 12. Site map supplied by Owner. 13. No vehicular or livestock traffic allowed on bed. 14. The location of the mound may be adjusted in field to better fit the site, provided all setbacks are met. DESIGN CALCULATIONS: 1. Calculate design flow: Bedrooms = 4 Q = 4(2)(75) = 600 GPD 2. For 4 bedrooms, use 1250 gallon septic tank — allow for buoyancy effects. 3. Determine area of field: (natural soils = 5 MPI) For sand filter, 0.95 gallons/sf/day (For use with garbage disposal) Area of bed = 1.95(600) - 0.055(600) (natural soils] 0.95 Area = 1198.58 square feet USE: 24'x50' bed (1200 sq.ft.) REGrll, CAUTION NOTE : fi� Q• •'•••.•F'%� _ `��•• l'�p DUE TO THE POSSIBILITY OF HIGH GROUND WATER T, SEPTIC TANK AND DOSING TANK MAY REQUIRE SPECIA INSTALLATION PRACTICES TO ASSURE THAT BUOYANif EFFECTS FROM THE GROUNG WATER DO NOT CAUSE 22• ti THE TANKS TO 'FLOAT" OUT OF THE GROUND. `.Z. •� DESIGN CALCULATIONS: 1. Calculate design flow: Bedrooms = 4 Q = 4(2)(75) = 600 GPD 2. For 4 bedrooms, use 1250 gallon septic tank — allow for buoyancy effects. 3. Determine area of field: (natural soils = 5 MPI) For sand filter, 0.95 gallons/sf/day (For use with garbage disposal) Area of bed = 1.95(600) - 0.055(600) (natural soils] 0.95 Area = 1198.58 square feet USE: 24'x50' bed (1200 sq.ft.)