HomeMy WebLinkAboutpitkin.eh.246725200001 (2012)0 � T O �4SITE WASTEWATER TREA'NT SYSTEM (OWTS)
EH/NRCONSTRUCTION PERMIT
76 Service Center Rd. Aspen, CO - 81611
Phone: 970.920.5070 Fax: 970.920.5374
Permit #: 0013.2012.powt
Parcel ID #:
2467-252-00-001
Permit Issued: ®NEW ❑REPAIR ®REMODEL/ADDITION ❑TANK ONLY ❑FIELD ONLY [-]AMENDMENT
Owner(s): Barry Wehmiller Group
Property Address:
Legal Description:
100 East River Ranch Rd
Size of Lot: 27
Size of Building: 2500
Acres Detached Accessory Unit: ®YES ❑NO
Sq. Ft. Size of Accessory Unit:
The system is designed for: 4 bedrooms plus a barn with 4 horse stalls and restroom facilities.
Designed By: All Service Septic
Phone #: 970-618-5033
Project #:
1931 Dated
Mailing Address: Po Box 2844, Glenwood Springs
Fax #: 303-216-2796 Email Address: Tpetzl@comcast.net
Perc Rate: 36 MPI Profile Hole Depth: 8' Depth to Groundwater or Bedrock:
Minimum Tank Capacity: 1312 gallons Minimum Absorption Area
Permit Conditions:
Sq. Ft.
3/2112
Greater than 8 ft
1235 sa. ft. w/ 30% reduction
This OWTS Construction Permit is approved on the condition of compliance with the engineer design as submitted with the application and the specifications
cited above. Changes must be approved by this Department and the engineer prior to construction.
This permit is for a septic system to serve both the residence and barn with caretaker unit. a 1250 gallon, 2
compartment septic tank will be used. Effluent filters in the outlet T of each tank are required. These tanks will both flow into
a concrete distribution box that must be level and accessible from grade. The D -box will equally distribute effluent to each of
the 5 gravelless chamber trenches, each with 25 "Quick 4" Infiltrator units. Trenches must be at least 6 feet of undisturbed soil
between them and trenches will be a minimum of 2 feet and deep and maximum of 3.5 feet. Observation ports will be installed
at the end of each trench.
The existing ditch along the edge of the new field area must be either abandoned or moved prior to completion of the system
so it meet the minimum set back distance of 50 feet.
This Permit must be kept on-site during installation. The engineer must do a final inspection of the installation and submit an "as -built" letter to this
Department within 30 days of the final inspection, unless a longer period of time has been agreed upon, in writing. This Department must also be called for
the final inspection with a minimum of 48 hours notice.
Minimum horizontal distances between components of the system and physical features shall conform to the requirements of the Pitkin County OWTS
Regulation.
This Permit is conditioned upon the property owner(s) providing for regular inspection, cleaning, and maintenance of the system by qualified personnel, in
accordance with the manufacturer's recommendations and the requirements of the Pitkin County OWTS Regulation. Issuance of this OWTS Construction
Permit does not constitute a guarantee, warranty, or representation by the Department that the system will operate properly or will not fail.
THIS PERMIT IS EXPRESSLY CONDITIONED UPON COMPLIANCE WITH ALL REQUIREMENTS OF THE PITKIN
COUNTY OWTS REGULATION, INCLUDING BUT NOT LIMITED TO THOSE CONDITIONS SPECIFIED ABOVE.
Plans and specifications for the proposed OWTS have been reviewed and are considered satisfactory. Permission is hereby
given to the property owner(s) to perform the work indicated in accordance with the Pitkin County OWTS Regulation. This
Permit will expire 1 year from the date of issuance unless construction on the system has commenced. An "as -built" drawing
must be submitted and approved by EH before final approval of the system will be issued.
Issued By: Bryan Daugherty, REHS Date: 6/20/12 Expires: 6/20/13
Installer: SaJCt OtAL 'EyGqo < License #:
Reactivation Authorized by:
Final Approval sued B ( Date; }
New Expiration Date: E] Fier- PaW
Z� �'i
Parcel ID# (available from the Pitkin County Assessor's Office
970-920-5160 or at www.nitkinassessor.ora):
/ ^
(e 7 1
Purpose of Permit: ❑ NEW ❑ REPAIR DUE TO FAILURE
V REMODEL/ADDITION ❑ TANK ONLY ❑ FIELD ONLY
Cost of System Repair or Remodel/Addition (approximate):
Business Phone: 970.927.6620 ext 25
Property Address: 100 East River Ranch Rd., Snowmass, CO
1Sp Email Address: eed @ michaelfullerarchitects.com
Lot: Block: Filing:
Subdivision:
Property Owner(s)*: Email Address:
Barry Wehmiller Group
owner's Mailing Address: 8020 Forsyth Blvd City, State, zip: Saint Louis, MO 63105
Home Phone: Business Phone: 314-862-8000
*rnntart information must be provided for the owner signing this application
Primary Contact Person/Applicant (if not owner): Jill Speed
Company: Michael Fuller Architects
Contact/Applicant Mailing Address: 23400 TWO Rivers Rd #41
City, State, zip: Basalt, CO 81623
Cell Phone:
Business Phone: 970.927.6620 ext 25
Fax Number: 970.927.5366
1Sp Email Address: eed @ michaelfullerarchitects.com
Building Permit # (if applicable): 0003.2012. PRBK and 0004.2012. PRBK
Lot Size (in acres): +/- 26.95 acres
vi,l( c;t.te
Size of Building (square feet): Number of Potential Bedrooms:
Ag Barn: 8453 sf + House: 1214 = 9667
Detached Accessory Unit? Size of Accessory Unit (square feet):
❑ YES ❑ NO li Cj
Number of Potential Bedrooms In or Fixture List for the Accessory Unit:
,-A (CNk to ba,\n 000 SA
Water Source:
X PRIVATE WELL ❑SURFACE WATER ❑SPRING ❑COMMUNITY/PUBLIC WATER SYSTEM
Name of Community/Public Water System (if applicable):
Engineering Firm: Job Number: Phone Number: Fax Numbe
All Service Septic 1931 970.618.5033 303.216.2796
Mailing Address: P.O. Box 2844 City, State, zip: Glenwood Springs, CO 81602
PLEASE READ BEFORE SIGNING:
I certify that the above information is complete and accurate and that I have provided complete and accurate information in all of the documents
included in my application package. I acknowledge that EH/NR may revoke any permit I am issued if my application is found to contain any
inaccurate, false, or misleading information. I understand that no construction may be undertaken on an OWTS until an OWTS Construction Permit is
issued.
C
Box 2844
L• Glenwood Springs, t0 81602
001 Ph 970.618.5033
Fax 303-216.2796
February 7, 2013
Erik Hendrix
Michael Fuller Architects
23400 Two Rivers Road, Suite 41
Basalt, CO 81621
eehendrixkme.com
Installation Observations
100 East River Ranch Road
Pitkin County, Colorado
OWTS Construction Permit 0013.2012.powt (B)
Erik,
c
Project No. 1931
ALL SERVICE septic, LLC observed the installation of the septic tank that will serve the cabin on
February 5, 2013 for the subject property.
A 1000 -gallon Roth® poly tank with an effluent filter on the outlet tee was installed. Effluent lines
out of the building were routed to this tank; however, no cleanouts were installed. The line has been
tied into effluent line exiting the barn which is already connected to the existing absorption area
which was installed in August 2012 (OWTS Construction Permit 0013.powt). This cabin will be
demolished and a new, 2 -bedroom "Shack" will be constructed in August/September 2013. This tank
may be relocated closer to the "Shack", at which time Pitkin County Environmental Health and ALL
SERVICE septic, LLC should be notified. Additional permitting may be required for this relocation.
The septic tank was generally installed according to specifications. This observation is not a
guarantee of workmanship and/or parts and materials. ALL SERVICE septic, LLC should be notified
if changes are made to the OWTS.
LIMITS:
The observations were based on information submitted. If conditions are different from conditions
described in this letter, ALL SERVICE septic, LLC should be notified. Any additional OWTS
construction must be according to the county regulations. The installer should have documented and
demonstrated knowledge of the requirements and regulations of the county in which they are
working.
Please call with questions.
Sincerely,
ALL SERVICE septic, LLC
O -OA (�_ OS-�&A8
Carla Ostberg, MPH, REHS
Reviewed By:
,xtdtt
dy p8,
AtPC,
56 wk
Tim Petz, P.G.
Cc: Eric Peirson, Pierson Consultants, LLC
Roth® 1000 gallon, two-compartment tank
Inlet tee
Effluent filter on outlet tee
Effluent line looking from tank, to toward the well
1000 -GALLON ,
TWO-COMPARTMENT
ROTH@ POLY TANK WITH
EFFLUENT FILTER
77
k
PROPOSED SHACK
H{� P.O. Bax 2846
Ga'. 111,11, Cdoratlo81602
JRJJJ E Phan.970.618.5033
Ip' Fax 303.216 2796
Redstone RanchI Cabin tank
100 Eaat RNer Ranch Road 02/07/13
P@kin County, Cobrado RECORD
Project Number, 1931
I
IN
4SITE WASTEWATER TREATN..:JT SYSTEM (OWTS)
CONSTRUCTION PERMIT
76 Service Center Rd. Aspen, CO - 81611
Phone: 970.920.5070 Fax: 970.920.5374
Permit #: 01 4.2012.powt (B) Parcel ID #:
2467-252-00-001
Permit Issued: ®NEW ❑REPAIR ❑REMODEL/ADDITION ®TANK ONLY ❑FIELD ONLY ❑AMENDMENT
Owner(s): Barr}
Property Address:
Legal Description:
Size of Lot: 27
Size of Building:
Wehmiller Group
100 East River Ranch Rd
2500
Acres
Sq. Ft.
Detached Accessory Unit:
Size of Accessory Unit:
The system is designed for: Tank only permit for 2 bedroom home to the north of the barn.
Designed By:
Phone #:
Fax #:
Sq. Ft.
All Service Septic Project #: 1931 Dated: 3/2/12
970-618-5033 Mailing Address: Po Box 2844, Glenwood Springs
303-216-2796 Email Address: Tpetz1(a)comcast.net
Perc Rate. 36 MPI Profile Hole Depth:
Minimum Tank Capacity: 1312 gallons
8' Depth to Groundwater or Bedrock: Greater than 8 ft
Minimum Absorption Area: 1235 sq. ft. w/ 30% reduction
Permit Conditions:
This OWTS Construction Permit is approved on the condition of compliance with the engineer design as submitted with the application and the specifications
cited above. Changes must be approved by this Department and the engineer prior to construction.
This permit is for a 2 compartment concrete 1500 gallon tank to be installed at the new 2 bedroom home north of the new
barn. It will be hooked into the new septic system (13.2012.POWT) as originally designed.
This Permit must be kept on-site during installation. The engineer must do a final inspection of the installation and submit an "as -built" letter to this
Department within 30 days of the final inspection, unless a longer period of time has been agreed upon, in writing. This Department must also be called for
the final inspection with a minimum of 48 hours notice.
Minimum horizontal distances between components of the system and physical features shall conform to the requirements of the Pitkin County OWTS
Regulation.
This Permit is conditioned upon the property owner(s) providing for regular inspection, cleaning, and maintenance of the system by qualified personnel, in
accordance with the manufacturer's recommendations and the requirements of the Pitkin County OWTS Regulation. Issuance of this OWTS Construction
Permit does not constitute a guarantee, warranty, or representation by the Department that the system will operate properly or will not fail.
THIS PERMIT IS EXPRESSLY CONDITIONED UPON COMPLIANCE WITH ALL REQUIREMENTS OF THE PITKIN
COUNTY OWTS REGULATION, INCLUDING BUT NOT LIMITED TO THOSE CONDITIONS SPECIFIED ABOVE.
Plans and specifications for the proposed OWTS have been reviewed and are considered satisfactory. Permission is hereby
given to the property owner(s) to perform the work indicated in accordance with the Pitkin County OWTS Regulation. This
Permit will expire 1 year from the date of issuance unless construction on the system has commenced. An "as -built" drawing
must be submitted and approved by EH before final approval of the system will be issued.
Issued By: Bryan Daugherty, REHS Date: 10/1/12 Expires:
10/1/13
Installer: License #: -
Reactivation Authorized by:
Final Approval Issued By: Date:
New Expiration Date: El Feep�md
C
PO Box 2844
r G1enwoWSpdngs,C081602
Ph 970.618.5033
L
W303-216-2796
August 26, 2012
Erik Hendrix
Michael Fuller Architects
23400 Two Rivers Road, Suite 41
Basalt, CO 81621
eehendrixgme.com
Installation Observations
100 East River Ranch Road
Pitkin County, Colorado
OWTS Construction Permit 0013.2012.powt
Erik,
C
Project No. 1931
ALL SERVICE septic, LLC observed the installation of the onsite wastewater treatment system
(OWTS) on August 21St and 23`d for the subject property.
The first tank that was installed was found to be cracked and was replaced. The installation included
a 1250 -gallon, two-compartment Copeland concrete septic tank with an effluent filter. A distribution
box, accessible from grade, distributes effluent to five gravelless chamber trenches. Each trench
consists of 20 -ARC 36 chambers, for a total of 100 chambers, or 1234 SF of infiltrative area.
The OWTS was generally installed according to specifications. This observation is not a guarantee of
workmanship and/or parts and materials. ALL SERVICE septic, LLC should be notified if changes
are made to the OWTS.
LIMITS:
The observations were based on information submitted. If conditions are different from conditions
described in this letter, ALL SERVICE septic, LLC should be notified. Any additional OWTS
construction must be according to the county regulations. The installer should have documented and
demonstrated knowledge of the requirements and regulations of the county in which they are
working.
Please call with questions.
Sincerely,
ALL SERVICE septic, LLC
0'alf-L (. L' 68_�&Ats
Carla Ostberg, MPH, REHS
Reviewed
Richard B
Crack in first tank installed — this tank was removed.
tank.
Inlet tee of 1250 gallon, two -comp tank.
Effluent filter on outlet tee of 1250 gallon, two -comp
•
D -box filled with water at time of inspection.
D -box brought to grade. Insulation cut out.
Trench installation
ich installation
Greater than 6' undisturbed soil between each trench.
Trenches covered
'ADS ARC 36' CHAMBER
TRENCHES. 20 CHAMBERS
PER TRENCH
= 100 CHAMBERS = 1234 SF
w OBSERVATION PORTS
4" SDR -35 SEW"PIPE
WITH CLEANOUST
(2% SLOPE TO TAN
1250 -GALLON;
TWO-COMPARTMENT
CONCRETE SEPTIC TA K
WITH EFFLUENT FILTER
4" SDR -35 SEWER PIPE
(1% SLOPE TO FIELD)
50' to ditch
NOTE: HAIR TRAPS MUST BE PLACED
ON FLOOR DRAINS IN HORSE
STALLS 2 BEDROOM
FRESIDENCE
W 4 HORSE STALLS
AL E
W
64'
vel F;
HI I P.o. ao, 2— Redstone Ranch
L L GlenwooE S9Ngs, ColaaCo B1fi02 100 Eaat r nancM1 RoaO RR-11nllllwr PM1one 9]0.818.5033 Pitkin Countt y. Calnado
II4`1t ��IIQ}Q} Fax 303.216.2]% Project Number. 1931
n
Bryan Daugherty
From: Carla Ostberg CBO Inc [cbo2610@yahoo.com]
Sent: Tuesday, June 19, 2012 7:36 PM
To: Bryan Daugherty
Cc: J.Ray Barlow; Tim Petz
Subject: Redstone Ranch
Attachments: DSCN6125.jpg
Hi Bryan,
We have discussed the issue of the ditch (see attached photo) with the ranch manager and the
decision has been made to abandon the ditch prior to installation of the system (and CO of any of the
structures). The ditch, within 50' of any point of the ditch, will be filled in and completely
abandoned. We will assure that there is no route that water can travel toward or within 50' of the
absorption area with the abandonment.
This information should be suffucient to address your concerns about the ditch and proceed with
issuance of the OWTS Construction Permit, but please let me know if you need any additional
information or documentation. Thank you!
Carla Ostberg, MPH, REHS
Cell) 970-309-5259
Office) 970-704-0484
33 Four Wheel Drive Road
Carbondale, CO 81623
Email secured by Check Point
Pitkin County Environmental Health Department
Contact Log Sheet
Name: -
Parcel ID#: Address:
a Person S 9kert To Comments Actionto be Taken _. _ Initials Time
M IA r
b
4a"itt, Ics..
L. a c e C c o
-01
a
r
i
i � 6
x x
-
-.
'i
:J
PO Box 2844
.y' GGl97061&50.33 CO 81602
Ph SERY�C Fax303-216.2796
March 2°d 2012
Michael Fuller Architects
Attn: Jray Barlow and Jill Speed
23400 Two Rivers Road, Ste 41
Basalt, CO 81621
Onsite Wastewater Treatment System Design
100 East River Road
Pitkin County, Colorado
Jray,
11
Project No. 1931
ALL SERVICE septic, LLC performed a subsurface investigation and an onsite wastewater treatment
system (OWTS) design for the subject residence. The property is located outside of Aspen, in an area
where OWTS and wells are necessary. The subsurface investigation was prepared by our firm and is
presented under separate cover.
SITE CONDITIONS
Several structures exist on the subject property. Construction is planned with proposed construction
to include a 2 bedroom residence and barn structure having 2 bedrooms and 4 horse stalls. Any
current septic components will be abandoned. The proposed drain field area slopes gently to the west
southwest, and vegetation consists of a moderate cover of grasses with sparse trees. The property is
served by a well located 100+ feet from the proposed drain field.
SUBSURFACE
The subsurface was investigated by drilling one profile hole and three percolation holes, at the locations
indicated on the soils and percolation report. The materials in the profile hole consisted of 1 foot of
Jisandy clay root zone, underlain by sandy clay to 8 feet, the maximum depth explored. Groundwater or
bedrock was not encountered. Percolation rates ranged from 40 minutes per inch (MPI) to 27 MPI,
with an average rate of 36 MPI.
DESIGN SPECIFICATIONS
The OWTS design is based on a total of 4 -bedrooms, and 4 horse stalls, and an average sewage load
of 700 GPD. The installation must include two 1250 -gallon two-compartment septic tanks, with the
addition of an effluent filter, for each structure, to be followed by a trench gravelless chamber drain
field. The drain field must have 5 trenches and 125 total `Quick -4' Infiltratorrm chambers, equaling
1235 SF of infiltrative area. A concrete distribution box with a baffle must be installed. The box must
be brought to grade.
Onsite Wastewater Systems
Page 2
Construction must be according to the Pitkin County Environmental Health and Natural Resources
Department OWTS regulations, the OWTS Construction Permit provided by Pitkin County
Environmental Health and Natural Resources Department, and this design.
OPERATION INFORMATION AND MAINTENANCE
The surface of the drain field should be seeded upon completion. Vegetation is an important factor in
drain field performance. Erosion control should be practiced prior to and during re -vegetation. Geo -
fabrics or plastics should not be used over the drain field. No heavy equipment, machinery, or
materials should be placed on backfilled drain field. Livestock should not graze on the drain field.
Plumbing fixtures should be checked to ensure that no additional water is being discharged to OWTS.
For Example, a running toilet or leaky faucet can discharge hundreds of gallons of water a day and
harm a drain field.
The homeowner should pump the septic tank every two years and clean the effluent filter as needed.
Garbage disposal use should be minimized, and non -biodegradable materials should not be placed
into the OWTS. Grease should not be placed in household drains. Loading from a water softener
should not be discharged into the OWTS. No hazardous wastes should be directed into the OWTS.
Mechanical room drains should not discharge into the OWS. The OWTS is engineered for domestic
waste only.
ADDITIONAL CONSTRUCTION NOTES
NO staging of materials, or heavy machinery over the drain field area prior to construction.
Excavation equipment must not drive in excavation of drain field during construction due to the
potential to compact soil. If design includes a pump, air release valves and weep holes should be
installed to allow pump lines to drain to minimize risk of freezing. Extensions should be placed on all
septic tank components to allow access to them from existing grade. Precast concrete tanks and
distribution boxes should be used, unless plastic or fiberglass is required. Access to all tank
compartments and distribution devices is optimal.
INSTALLATION OBSERVATIONS
ALL SERVICE septic, LLC, and the county must view the OWTS during construction. The OWTS
observation should be performed before backfill, after placement of chambers and distribution pipes.
Septic tanks, distribution devices, pumps, dosing siphons, and other plumbing, as applicable, must
also be observed. ALL SERVICE septic, LLC should be notified 48 hours in advance to observe the
installation.
Onsite Wastewater Systems
Page 3
LIMITS:
The design is based on information submitted. If soil conditions encountered are different from
conditions described in report, ALL SERVICE septic, LLC should be notified. All OWS construction
must be according to the county regulations. Requirements not specified in this report must follow
county regulations. The installer should have documented and demonstrated knowledge of the
requirements and regulations of the county in which they are working.
Please call with questions.
Sincerely,
o�Ppp LIC C,
per; •'�ERBFgT..
ALL SERVIC ic, LLC Reviewed By �.ro
..,.
d 3Be
:�• 2 2'�1 •� �GVr
Timothy Petz Richard H.
3 copies
January 24, 2012
•
PO Box 2844
Glenwood Springs, CO 81602
Ph 970-618-5033
Fax 303-216.2796
Michael Fuller Architects
Attn: Jill Speed
23400 Two Rivers Road, Ste 41
Basalt, CO 81621
Subsurface Investigation and Percolation Report
100 East River Road
Pitkin County, Colorado
Project No. 1931
ALL SERVICE septic, LLC, performed a subsurface investigation and percolation test for the subject
property, on January 17th 2012. The test was performed in accordance with Pitkin County
Regulations.
EXISTING CONDITIONS AND STRUCTURES
The subject property is located in a residential area where Onsite Wastewater Systems (OWS) and
wells are necessary. There are several structures existing at the property, utilizing existing OWS. A
new residence is being planned. The slope at the area of the percolation holes is relatively flat, and
vegetation consists of sparse native grasses.
SUBSURFACE CONDITIONS AND CONCLUSIONS
The subsurface was investigated by drilling one profile hole and three percolation holes, at the locations
indicated on Figure 1. The materials in the profile hole consisted of 1 foot of sandy clay root zone,
underlain by sandy clay to 8 feet, the maximum depth explored. Groundwater or bedrock was not
encountered. Percolation rates ranged from 40 minutes per inch (MPI) to 27 MPI, with an average
rate of 36 MPI.
LIMITS:
Results are based on field investigations and data provided by the client. If soil conditions
encountered are different from conditions described in report, ALL SERVICE septic, LLC should be
notified
L
PITKIN COUNTY ENVIRONMENTAL HEALTH DEPARTMENT
Percolation Test and Soils Data Form - TABLE 1 - PROJECT 1931
Performed by All Service Septic, LLC
PROFILE PIT Date of Test: 1/17/2012
0 - 1.0' Clay, Sandy, Stiff, Root Zone, Moist, Red
1.0 - 8.0 Clay, Sandy, Stiff, with Sandy Layers, Moist, Red/Brown
No Groundwater or Bedrock was Encountered
Hole
No.
Hole
Depth (in.)
Interval
(min.)
Measurement at
Start of Interval
(in.)
Measurement at
End of Interval
(in.)
Change (in.)
Percolation Rate
(min./in.) MPI
1
35
20
11.50
13.25
1.75
17.00
17.75
0.75
20
13.25
14.25
1.00
20
18.25
19.00
20
14.25
15.00
0.75
20
15.00
16.00
1.00
20
16.00
16.50
0.50
20
16.50
17.00
0.50
40
2
34
20
12.25
14.25
1.75
20
14.25
15.00
0.75
20
15.00
16.00
1.00
fill
20
11.25
12.50
1.25
20
12.50
13.25
0.75
20
13.25
14.00
0.75
27
3 39 20
12.00
15.00
3.00
20
15.00
16.25
1.25
20
16.25
17.00
0.75
20
17.00
17.75
0.75
20
17.75
18.25
0.50 40
20
18.25
19.00
0.75
AVG = 36 MPI
`1
PATRICK 1 MILLER ! KROPF
Attomeys at Law wwwwaterlawcorn
Ramsey L. Kropf* February 20, 2012
shreholder
k�pf@wateriawcnm
repty to Aspen office J. Ray Barlow
Michael Fuller Architects PC
'licensed in AX co. WY' 23400 Two Rivers Road #41
Basalt, Colorado 81621-9255
irbarlow.b3(i , mail.com Via Email
RE: 100 E. River Road Adequate and Legal Water Supply (our file # 776C)
Dear J. Ray:
This letter serves to demonstrate the legal and adequate water supply supporting the
site and landscape plans for 100 E. River Road (the "Property") submitted by the
Barry-Wehmiller Group, Inc. to Pitkin County.
Domestic Water Supply: The legal domestic water supply for the house, large
barn, and small barn will be provided by the exempt well currently located on the
Property. The well is permitted under Well Permit No. 142415 for 15 gallons of
Main Office. water per minute ("gpm") for use inside up to 3 single-family dwellings, irrigation
730 E. Durant Avenue of 1 acre of lawn and garden, stock watering, and fire protection purposes. The
Suite 200 permit information is attached as Exhibit A. The Barry-Wehmiller Group was
Aspen, CO 81611 assigned this permit on February 3, 2011, recorded at Reception No. 577413, Pitkin
`I'. 970.920.1028 County Clerk and Recorders.
E 970.925.6847
The water supply provided by this well is sufficient to serve all three dwellings, as
99918t Scree. well as provide for the irrigation of 1 acre of the proposed landscaping, the watering
9991 8th Street
30th Floor of a small number of domestic animals, and the protection of the Property from fire.
Denver, CO 80202 The well draws from Roaring Fork River alluvium and is "exempt" from the prior
T. 303.893.9700 appropriation doctrine, meaning it is never curtailed in times of shortage to benefit
F. 303.893.7900 senior water rights. Additionally, in April 2010, the Barry-Wehmiller Group
Phocommissioned a pump test on the well to determine its potential yield. The test
2415 E. nix office` Cametback revealed that the well produces 27 gpm — a volume significantly greater than its
Suite
Suite 700 permitted 15 gpm. A letter from Beach Environmental, LLC summarizing the test
Phoenix, A7.85016 is attached as Exhibit B.
't: 480.921.4044
1:480.921.8688 Irritation Water Supply: The legal irrigation water supply for the lawn,
plantings, orchard, and agricultural acres on the Property will be provided by
Tulsa E.
63r
Suit E. 03re 340-18 fficd Place diversions from the Last Chance Ditch out of the Roaring Fork River. The Barry -
Suite
Wehmiller Group was conveyed 0.5 cubic feet of water per second ("cfs") out of
uit
Tulsa, OK 74133 the Last Chance Ditch via the bargain and sale deed dated February 3, 2011,
T. 918.459.4634 recorded at Reception No. 577412, Pitkin County Clerk and Recorders. 0.5 cfs of
F. 970.925.6847 Last Chance Ditch water equates to five (5) shares (at 0.1 cfs per share) in the
a professional corporation
0 Q
PATRICK I MILLER I KROPF
J. Ray Barlow
Page 2
February 20, 2012
Snowmass Canyon Last Chance Ditch Company — the non-profit organization that governs ditch
maintenance and operations. On May 12, 2011, the Ditch Company formally issued Share
Certificate No. 016 for five shares to the Barry-Wehmiller Group. A copy of Share Certificate
No. 016 is attached as Exhibit C.
The water supply provided by the Last Chance Ditch is sufficient to irrigate the landscaping on
the Property. The Barry-Wehmiller Group plans to irrigate approximately 9 to 10 acres
(including the 1 acre that can be irrigated by Well Permit No. 142415, as described above). In
the Roaring Fork Valley, 0.5 cfs is typically enough water irrigate 20 to 25 acres using basic
flood irrigation practices. The Last Chance Ditch is additionally a fairly senior water right on the
Roaring Fork River. The Garfield County District Court decreed the Last Chance Ditch for
irrigation purposes on August 25, 1936 in Civil Action No. 3082. This adjudication date
indicates that the ditch runs consistently throughout the irrigation season in all but the very driest
of years. The state's diversion records confirm that the ditch receives on average 2.71 cfs of
water from May through October.
Pond Water: The Barry-Wehmiller Group does not own water rights for a pond on this
property. We suggest requesting that an approval is conditioned on the Barry-Wehmiller
securing appropriate water rights for a pond. There is an adequate physical source to fill a pond,
but water court proceedings will be necessary to secure the storage water rights.
In sum, we trust that the information provided sufficiently details the adequate and legal water
supplies for the Barry-Wehmiller Group's site and landscape plans. If you have any questions or
comments, please feel free to call or email at your earliest convenience.
Very truly yours,
PATRICK, MILLER & KROPF, P.C.
A Professional Corporation
Ramsey L. Kropf
kron f�a,waterlaw. com
RLK/dml
cc/encl: Robert Chapman
Judith Gettinger
WABarry-Wehmiller Group (chapman)\776 C\Letters\Barlow re adeqaute and legal water supply 2-17-12.doc
Form
STATE OF COLORADO
For Office Use Only
No.
OFFICE OF THE STATE ENGINEER
GWS -11
818 Centennial Bldg., 1313 Sherman St., Denver, CO 80203
8/2007
Phone — Info: (303) 866-3587 Main: (303) 866-3581
Fax: 303 866-3589 htt ://www. water. state. co. us
IRECFI�jr~C'
CHANGE IN OWNERSHIP/ADDRESS
CORRECTION OF THE WELL LOCATION
MAR 21 2011
Review instructions on the reverse side prior to completing the form.
\NSATA7E
r, t
Name address and phone of the person claiming ownership of the well:
NAME(S): Barry Wehmiller Group Inc
Mailing Address: 730 E. Durant Ave Suite 200
City, St. Zip: Aspen CO 81611 —
Phone 970 920-1028
This form is filed by the named individual/entity claiming that they are the owner of the well permitted as referenced above.
This filing is made pursuant to C.R.S. 37-90-143.
WELL LOCATION: Well Permit Number: 142415 Receipt Number:
County Pitkin Well Name or # (optional) AVR Well No. 1
(Address) (City) (State) (Zip)
SW 114 of the NW 1/4, Sec. 25 Twp. 8 ❑ N. or ® S., Range 86 ❑ E. or ® W., 6"' P.M.
Distance from Section Lines: 3140 Ft. From ❑ N. or ® S., 500 Ft. From ❑ E. or ® W. Line.
Subdivision Name Parcel B River Road Ranch Co/Gibbons Lot Line Adjustment
The above listed owner(s) say(s) that he, she (they) own the well described herein. The existing record is being amended for
the following reasons:
® Change in name of owner ® Change in mailing address ❑ Correction of location for exempt wells permitted prior to May
8, 1972 and non-exempt wells permitted before May 17, 1965.
Please see the reverse side for further information regarding correction of the well location.
I (we) claim and say that I (we) (are) the owner(s) of the well described above, know the contents of the statements made
herein, and state that thev are true to my (our knowledge.
ature(s) of the new owner
Please print the Signer's Name & Title
Date
Robert H. Chapman
Chairman of the Board & President
L j 3 zo L'?
It is the responsibility of the new owner of this well to complete and sign the form. Signatures of agents are acceptable if an
original letter of agency signed by the owner is attached to the form upon its receipt.
For Office Use Only
ACCEPTIEDAS A CHANGE OFOWNERSHip
4NWOk MAILINGADDRESS
State Engineer By VDate
9 -�rof
Beach Suite 4210
Environmental 0133 Prospector Rd. Tet: 970.925.3475
Aspen, CO 81611 Fax: 970.925.4754 www.beachenvironmental.com
April 19, 2010
Hal Dishler, Esq.
Kaufman, Peterson & Dishler
310 East Hyman Avenue
Aspen, Colorado 81611
Re: Wehmiller Water, Well and Environmental
Condition Update
Dear Hal:
Today I received the final test results on the water samples taken from the single well on
the Steve Main Ranch Property. The lab results indicate the water sampled complies with
all EPA requirements, and there were no occurrences of any analyte concentrations
exceeding any EPA maximum contaminant level. Therefore, the quality of water from
the well meets or exceeds the EPA's standard test for drink -ability. A copy of the lab's
water quality testing results is attached for your review and your client's use.
With that being said, I need to provide you with an advisement regarding the trace
amount of uranium detected in the water sample (0.0033 mg/L). Although the amount
detected is only a trace, and uranium is a naturally occurring element, we alert our client
whenever any radionuclide is detected as the existence of uranium may also indicate the
existence of radon gas, and or radium 226 and 228 in the water, all of which axe naturally
occurring and for which maximum contaminant levels have been set by the EPA. The
amount of uranium. found in this water is far below the EPA maximtun contaminant level
of 0.03 mg/L.
This customary advisement is not meant to cause alarm, nor to direct any further action,
because the existence of trace elements of uranium are common to many ground water
sources, and the removal of uranium or other radionuclides can be accomplished fairly
simply through a point -of use reverse osmosis system, or lime softening, ion exchange or
coagulation/filtration treatment options for all uses. We issue the advisement to ensure
the client is aware that this trace element exists and if concerns are valid due to other
health reasons, steps can be taken to further treat the water.
At the time the water quality samples were collected, the well was pumped to determine
its potential yield. The volume produced was 27 gallons per minute, static pressure was
measured at 49 psi, and temperature was 53 degrees Fahrenheit. A nephelometer was
used to determine turbidity, and registered less than 0.2 NTU, well less than the
maximum acceptable turbidity of 1 NTU.
There was no indication of any fault or concern with the pump's operation, which
appeared smooth and normal. Nor was there any notice -able variance in rate or volume
BEACH ENVIRONMENTAL, LLC Page -2
Febraary 19, 2004
of flow during the test.
Finally, although I was not asked to consult on this condition, there is a small but
controllable outbreak of noxious weeds that has occurred in several locations on and
immediately adjacent to the property. This consists primarily of Canada thistle and
plmneless thistle. These are both listed noxious weeds on the County's inventory list and
must be controlled by the landowner.
I spoke with Joanne Davis about the small communities and she said she was looking into
some method for spraying. I made a recommendation to her that due to the limited areas
and number of plants that the herbicide Milestone would be best applied by a back pack
sprayer. If we can provide any additional assistance on this issue or if the County
requires a weed survey to be completed during any future site planning process, we would
be pleased to identify and map the weed locations and develop a management plan.
I appreciate the opportunity to work with you on this project and if I can be of further
assistance or should you have any questions, please give me a call.
Sincerely,
By
G eac , MSEE, CES, R'WS
Principal
0514 well update .Wd
Email to:eary l)eachresource.com
Basalt Office - 711 Gast Valley Road, Basalt, CO 81621 tel. 970-273-3100
Carbondale Office - 4165 Crystal Bridge Drive, Carbondale, CO 81623 - 970-963-2287
State of Colorado Water ReSOun -View Well Details: Receipt 0260357
Colarado Nprtmyit of ^latera? Rescurces
Colorado's Well Permit Search
Well Constructed
Receipt: 0260357
Permit #: 142415 --
Well Name / #:
Designated Basin:
Case Number:
WDID:
Division: 5
Water District: 38
County: PTTIQN
Management District:
UEle1K Last Refresh: 2/15/201212:01:25 AM
[-] Applicant/Owners History
Date Range Applicant/Owner Name Address City/State/Zip
Unknown - Present BARRY-WEHMILLER GROUP INC CfO PATRICK MILLER & KROPP PC 730 E DURANT AVE STE 200 ASPEN, CO 81611-
[-] Location Information
Approved Well Location:
Q40 Q160 Section Township Range PM Footage from Section Lines
SW NW 25 8.05 86.OW Sixth 3140 S 500 W
Northing (UTM y}: 4355225.0 Easting (UTM x): 331751.0
Location Accuracy: User supplied
Physical Address Subdivision Name
ASPEN RIVER VALLEY RANCH
City/State/Zip Filing Block Lot
11
Parcel ID: 49-2467-252-00-590 Acres in Tract: 42.84
[-] Permit Details
Date Issued, 12/20/1985 Date Expires:
Use(s): DOMESTIC Aquifer ALL UNNAMED AQUIFERS
Special Use: ISSUED UNDER PRESUMPTION 3b -ITA (s):
Area which may be irrigated: 1 ACRES
Maximum annual volume of appropriation:
Statute:
Permit Requirements: Totalizing Flow Meter Geophysical Log Abandonment Report
No No No
Cross Reference Permit Number Receipt Description
Permit(s):
Comments:Only well on 42.84 acre tract (aka lot 11, Aspen River Valley Ranch). Limit use to 3
SFD, 1 acre lawn & garden irrig & water domestic animals. Tax #RO09090. Phy
address: 300 E RIVER RANCH RD SNOWMASS, dmw 5/21/08
[-]
Construction/ Usage Details
Well Construction Date: 04/16/1986 Pump Installation Date:
Well Plugged: 1st Beneficial Use:
Elevation Depth Perforated Casing (Top) Perforated Casing (Bottom) Static Water Level Pump Rate
85 48 85 39 15
Lic # Name Address Phone Number
Driller 894 SHELTON, STEVE PO BOX 81S BUENA VISTA, CO 81211 719.395-3215
[-] Application/ Permit History
Ownership Change 03/21/2011
Well Construction Report Received 04/23/1986
Well Constructed 04/16/1986
Permit Issued 12/20/1985
Application Received 11/12/1985
[-] Imaged Documents
Document Name Date Imaged Annotated
Chang4.in Oviner game/Address 03/24/2011 No
Oriainai File 12/05/2007 No
O 2CD9 Colorado Division of Water Resources. All rights reserved.
Hoare I Contact Us I Hell) I Water Links I Coiorado.gov I DNR I Privacy Policy I Transparenq Online Project (TOP)
Page 1 of 1
Cclorado.gov i Contact Us
http://www.dw .state.co.us/WellPermitSearcli/View.aspx?receipt 0260357 2/15/2012
—WRJ•5-pev.76COLORADO C N OF WATER RESOURCES
' DIVISION 0
818 Centennial Bldg., 1313 Sherman St., De C*jVF..12 2 1985
PERMIT APPLICATION': RESIDI)M
Application must STATE EN6IMM
be complete where tX) A PERMIT TO USE GROUN Fig cam
applicable. Type or (X) A PERMIT TO CONSTRUCT
print in BLACK FOR: (X) A PERMIT TO INSTALL A P
IN K. No overstri kes
or erasures unless ( ) REPLACEMENT FOR N0.
initialed. ( ) OTHER — - —
WATER COURT CASE NO.
(1) APPLICANT - mailing address
NAME Stephen Main, co—tenant
STREET 1621 River Road
CITY Woody Creek, CO 81656
(State} (ZIp7
TELEPHONE NO. 303`923-4768
(2) LOCATION OF PROPOSED WELL
County Pitkin
SW % of the NW %, Section 25
Twp. —a— — S , Rng- —8.6. _--_ W , — — C, t h
�N,9 lEVI
{3} WATER USE AND WELL DATA
Proposed maximum pumping rate (gpml is
Average annual amount of ground water
to be appropriated (acre-feet): ( S
Number of acres to be irrigated: 1
Proposed total depth tfeet): 15Q
Aquifer ground water is to be obtained from:
Roaring Fork Alluvium
Owner's well designation AVR WP 7 -1 Nn 1
GROUND WATER TO BE USED FOR:
JJI ( 1 HOUSEHOLD USE ONLY - no irrigation (0)
( X) DOMESTIC (1) ( 1 INDUSTRIAL (5)
{ 1 LIVESTOCK (2) ( ) IRRIGATION t81
( ) COMMERCIAL M) ( ) MUNICIPAL (8)
) OTHER (9)
DETAIL THE USE ON BACK IN 01)
(4) DRILLER
Name Licensed Driller
Street
City
�$I atCt (Zip)
-:r
RECEIVED
NOV 12 1595
NATER M300CM
$(A; E - >:t16#"
MA
FOR OFFICE USE ONLY: 00 NOT WRITE IN THIS COLUMN
Receipt No. �e�5� _ 1
Basin Dist,
CONDITIONS OF APPROVAL
This well shall be used in such a way as to cause
no material injury to existing water rights. The
issuance of the permit does not assure the appiicant
that no injury will occur to another vested water
right or preclude another owner of a vested water
right from seeking relief in a civil court action.
3) APPROVED PURSUANT TO,.CRS _. 37•-92-602
(3)(b)(II) AS THE UNLY WELL ON A TRACT OF
LAND OF r .tY ACRES DESCRIBED AS Aggr Qoc
AT-rACWeb FXN4sir A
2) -THE USE OF GROUND WATER FROM THIS WELL, 15
L MTTED TO ORDINARY HOUSEHOLD PURPOSES,
bitF� PROTECTION, TUE WATERING OF POULTRY,
DOMESTIC ANIMALS, AND LIVESTOCK ON
FARMS AND RANCHES, AND THE IRRIGA—
TION OF NOT OVER ONE ACRE OF HOME
GARDENS AND LAWNS, BUT NOT USED FOR
MORE THAN THREE SINGLE—FAMILY DWEL—
LINGS.
3) THE RETURN FLOW FRIOR THE USE OF THE WELL
'MUST BE THRU WASTE WATER DISPOSAL SYSTEMS
OF THE NON—EVAPORATIVE TYPE WHERE THE WATER
IS RETURNED TO THE SAME STREAM SYSTEM IN
WHICH THE WELL IS LOCATED.
— CONTINUED, ATTACHED SHEET —
APPLICATION APPROVED
PERMIT NUMBER 1424 a 5
DATE ISSUED DEC 2 0 1985
EXPIRATION DATE OEG 2 0 1987
g
Telephone No. Lic. No,
COUNTY
I
(5) THE LOCATbQ bF"THE' PROPOSED WELL and the area on (6) THE WELL MUST BE LOCATED-BEL•OW
w is the water will be used must be indicated on the diagram below. by distances from section lines.
Use the CENTER SECTION 1I.sqation, 840 acres) for the well location.
1 .L 1 ft, from sec. line
T 1 i '� _`'...+ T ..._ ._i.. ...�. north or south)
[{ t MILE, 5280 FEET ---10 ft. from sec. line
(east or wast)
+ + + + f + + + + LOT BLOCK F I LING
� I i I
^i
NORTH SECTION LINE SUBDIVISION
+
I
�NORTHW
+ z
J
i zz
U
I
i
W
– — �}
f
5 +
I
X
[ i
W
-iAL
I 1
SUU I M Sot:! IUN LiNt
I (7) TRACT QN WHICH WELL WILL BE
LOCATED Owner: Stephen Main,
M + + s
a. of acres 4 2 . 8 4 CO–ten. ll4l1 this be
I I'
+ 500+ft. irem 4&st _�(ecti(t Line
13140 ft. from SouthiSection Li�
The scale of the diagram is 2 inches = 1 mile
Each small souare represents 40 acres.
WATER EQUIVALENTS TABLE (Rounded Figures)
An acre-foot covers I acre of land I foot deep
1 cubic foot per second (cfsl ... 449 gallons per minute (gpml
A family of 5 will require approximately 1 acre-foot of water per year.
I acre-foot ... 43,560 cubic feet ... 325,900 gallons.
1.000 gpm pumped continuously for one day produces 4.42 acre-feet.
the only well on this tract? YPS
(8) PROPOSED CASING ,_PROGRAM
Plain Casing
6 in. from 0 ft. to 100 it.
in. from ft, to ft_
Perforated casing
6 in. from 100 ft. to 150 ft.
in. from ft. to `t.
(9) FOR REPLACEMENT WELLS givedistance
and direction from old well and plans for plugging
it:
(10) LAND ON WHICH GROUND WATER WILL BE USED
Owner(s); Stephen Main, co–tenant No. of acres: 49-84
Legal description: See Exhibit A
(11) DETAILED DESCRIPTION of the use of ground water: Household use and domestic wells must Indicate type of disposal
system to be used.
21I1 t1Se.^., deScrlbud in cm
wastewater,
��""9�"y`�� (11 (�� ; nfl_n–�`r�t^,n+-ranar•iral isre
wastewater df gppsal cyst ms -
(12) OTHER WATER RIGHTS used on this land, including wells. Give Registration and Water Court Case Numbers.
Type or right
Used for (purpose)
Description of land on which used
it Chance Dftgh — Irrigation Approximately 30 acres
ICANT(S) STATE(S) THAT THE INFORMATION SET FORTH HEREON IS
THE BEtPVF PIIS KNQWLEDGE.
APPL
Use additional sheets of paper if more space is required.
SUU I M Sot:! IUN LiNt
I (7) TRACT QN WHICH WELL WILL BE
LOCATED Owner: Stephen Main,
M + + s
a. of acres 4 2 . 8 4 CO–ten. ll4l1 this be
I I'
+ 500+ft. irem 4&st _�(ecti(t Line
13140 ft. from SouthiSection Li�
The scale of the diagram is 2 inches = 1 mile
Each small souare represents 40 acres.
WATER EQUIVALENTS TABLE (Rounded Figures)
An acre-foot covers I acre of land I foot deep
1 cubic foot per second (cfsl ... 449 gallons per minute (gpml
A family of 5 will require approximately 1 acre-foot of water per year.
I acre-foot ... 43,560 cubic feet ... 325,900 gallons.
1.000 gpm pumped continuously for one day produces 4.42 acre-feet.
the only well on this tract? YPS
(8) PROPOSED CASING ,_PROGRAM
Plain Casing
6 in. from 0 ft. to 100 it.
in. from ft, to ft_
Perforated casing
6 in. from 100 ft. to 150 ft.
in. from ft. to `t.
(9) FOR REPLACEMENT WELLS givedistance
and direction from old well and plans for plugging
it:
(10) LAND ON WHICH GROUND WATER WILL BE USED
Owner(s); Stephen Main, co–tenant No. of acres: 49-84
Legal description: See Exhibit A
(11) DETAILED DESCRIPTION of the use of ground water: Household use and domestic wells must Indicate type of disposal
system to be used.
21I1 t1Se.^., deScrlbud in cm
wastewater,
��""9�"y`�� (11 (�� ; nfl_n–�`r�t^,n+-ranar•iral isre
wastewater df gppsal cyst ms -
(12) OTHER WATER RIGHTS used on this land, including wells. Give Registration and Water Court Case Numbers.
Type or right
Used for (purpose)
Description of land on which used
it Chance Dftgh — Irrigation Approximately 30 acres
ICANT(S) STATE(S) THAT THE INFORMATION SET FORTH HEREON IS
THE BEtPVF PIIS KNQWLEDGE.
APPL
Use additional sheets of paper if more space is required.
APPLICANT: STEPHEN 1MAIN, CO -TENANT
WELL PERMIT NO. J •�. `T 5
CONDITIONS OF APPROVAL, CONTINUED:
4) A TOTALIZING FLOW METER MUST BE INSTALLED ON THE WELL AND MAINTAINED
IPF GOOD WORKING ORDER. PERMANENT RECORDS OF ALL DIVERSIONS MUST BE
MAINTAINED BY THE WELL OWNER (RECORDED AT LEAST ANNUALLY) AND SUBMITTED
TO THE DIVISION ENGINEER UPON REQUEST. /'.-'f8'S"S-
WJR.21t_7; ° RECEIVED
COLORADO DIVISION OF WAFER RESOURCES
THIS FORM MUST BE SUBMITTED 1313 Sherman Street - Room 818 APR 2 31986
WITHIN 60 DAYS OF COMPLETION Denver, Colorado 80203
OF THE WORK DESCRIBED HERE- WAnR RFS
ON. TYPE OR PRINT IN BLACK WELL COMPLETION AND PUMP INSTALLATION REPORT CE. JIJGLVJB
INK. PERMIT NUMBER 142415 CMA
WELL OWNER Stephen Dain SW y. of the ' NW Y. of Sec. 25 & 21
ADDRESS 1621 River Rd, Woody Creek, CO 81656 T. 8 _q_ R, _86 W , _ 6th P.M
DATE COMPLETED April 16 19 86 HOLE DIAMETER
WELL LOG — 7 in. from 0 to 68 ft.
Water. A_
in. from 68 to 85 it.
in, from to � ft.
DRILLING METHOD --Cable tool
CASING RECORD: Plain Casing
Size �'� & kind Steel from _- 0 to _48 It.
Size T.__ & kind from to ft.
Size _�_ & kind from to ft.
Perforated Casing
Size 7" - & kind _ 5tee1 from _48 to 68 ft.
Size _.� & kind PVC from _ to , 85 ft.
Size & kind from to ft.
GROUTING RECORD
Material Cement
Intervals 5_156
Placement Method Gravi
GRAVEL PACK
Interval _
TEST DATA
Size
Date Tested April 16 1 1 9 86
Static Water Level Prior to Test 39 ft.
Type of Test Pump Bailer
Length of Test 3 Hrs •
Sustained Yield (Metered-; _�_15 GPM
Final Pumping Water Level _ 449
i .,:1't'I .+JMP INSTALLATION REPORT
Pump Make
Type
„PoWered by HP
Pump Serial No.
Motor Serial No.
Date Installea ._
Pump Intake Depth
Remarks
WELL TEST DATA WITH PERMANENT PUMP
Date Tested
Static Water Level Prior to Test
Length of Test Hours
Sustained yield (Metered) GPM
Pumping Water Level
Remarks - -
a�.
r
w
,
�
WATER
W v Uj
W TABLE
W
r
i
d
r
r
CON I- OF
DEPRESSION
CONTRACTORSSTATEMENT
The undersigned, being duly sworn upon oath, deposes and says that he is the contractor of the well or
pump installation described hereon; that he has read the statement made hereon; knows the content
thereof, an s true of his o knowledge.
Signature L Lieense No.
State of Colorado, County of Cc SS
t �+
Subscribed and sworn to betore me this D day of 4 19 t�Y01
.
MY Gammission ex ' es.
Ngtary Public �Y Zoelmjssion �fxplres �+r» 14.� 1g -
FORM TO BE MADE OUT IN QUADRUPLICATE: WHITE FORM must be an original copy an both aides and signed.
WHITE AND GREEN copies must be filed with the State Engineer, PINK COPY is for the Owner and YELLOW COPY is for the DrilJer.
Form
STATE OF COLORADO
For Office Use Only
No.
OFFICE OF THE STATE ENGINEER
GWS-11
818 Centennial Bldg., 1313 Sherman St., Denver, CO 80203
812007
Phone— Info: (303) 866-3587 Main: (303) 866-3581
Fax: 303 866-3589 http://Www.water.staie.co.us
ECFI�jE�:,
CHANGE IN OWNERSHIP/ADDRESS
CORRECTION OF THE WELL LOCATION
MAR 1 2Qi�
��R 2
Review instructions on the reverse side prior to completing the form.
VVATEF
Name address and phone of the person claiming ownership of the well:
NAME(S): Barry-Wehmiller Group, Inc.
Mailing Address: 730 E. Durant Ave Suite 200
City, St. Zip: Aspen CO 89611
Phone 974 920-9428
This form is filed by the named individual/entity claiming that they are the owner of the well permitted as referenced above,
This filing is made pursuant to C.R.S. 37-90-143.
WELL LOCATION: Well Permit Number: 142415 Receipt Number:
County Pitkin Well Name or # (optional) AVR Well No. 1
(Address) (City) (State) (Zip)
SW 114 of the NW 114, Sec. 25 Twp. 8 ❑ N. or ® S-, Range 86 ❑ E. or ® W., 61' P.M.
Distance from Section Lines: 3140 Ft. From ❑ N. or ® S., 500 Ft. From ❑ E. or Z W. Line.
Subdivision Name Parcel B River Road Ranch Co/Gibbons Lot Line Adiustment
The above listed owner(s) say(s) that he, she (they) own the well described herein. The existing record is being amended for
the following reasons:
® Change in name of owner ® Change in mailing address ❑ Correction of location for exempt wells permitted prior to May
8, 1972 and non-exempt wells permitted before May 17, 1965.
Please see the reverse side for further information regarding correction of the well location.
I (we) claim and say that I (we) (are) the owner(s) of the well described above, know the contents of the statements made
herein, and state that they are true to m(our knowledge.
ature(s) of the new owner
Please print the Signer's Name & Title
Date
Robert H. Chapman
Chairman of the Board & President
Z 3 L-i
it is the responsibility of the new owner of this well to complete and sign the form. Signatures of agents are acceptable if an
original letter of agenGy agencysigned by the owner is attached to the form upon its receipt.
For Office Use Only
ACCEP7'EDASA CHANCE OFOWN6RSHbfi
AND/OR MAlL11VGADD1tES5
q
State Engineer By VDate
RESOLUTION OF THE BOARD OF COUNTY COMMISSIONERS OF PITKIN
COUNTY, COLORADO, GRANTING APPROVAL TO THE BARRY-WHEMILLER GROUP,
INC. FOR A MINOR AMENDMENT TO A DEVELOPMENT APPROVAL TO REINSTATE THE
REQUIREMENT FOR AN EMPLOYEE DWELLING UNIT DEED RESTRICTION AND ADD A
CARETAKER DWELLING UNIT DEED RESTRICTION
Resolution No.//f -2011
RECITALS
1. Barry-Wehmiller Group,inc. ("Applicant") has applied to the Board of County Commissioners of
Pitkin County, Colorado ("BOCC") for a minor amendment to a development permit to remove the
requirement for an employee dwelling unit ("EDU") deed restriction on the property and substitute a
caretaker dwelling unit (CDU) deed restriction on an existing unit in the barn.
2. The property is located at 100 East River Ranch Road (off Lower River Road), and is more specifically
described in Attachment A.
3. The lot contains 26 acres, and is conforming in size in the AR -10 zone district.
4. The lot was created pursuant to a Court ordered partition stipulated to by Pitkin County. The parcel was
granted a Growth Management allocation for one free market unit and one 3 bedroom low income
employee unit by BOCC Resolution No. 86-99. "1041 Hazard Review" approval for one free market
and one employee unit was granted by Planning and Zoning Commission Resolution No. 86-26. No
deed restriction was ever recorded on the EDU as required.
5. The BOCC heard this application at regularly scheduled meetings on August 10, 2011, September 7,
2011, October 26, 2011, and December 7, 2011, at which time evidence and testimony were presented
with respect to the application.
6. On October 26, 2011 the Applicant modified the application request, proposing that the existing two
bedroom primary residence be deed restricted as a Category 3 "EDU", that the existing unit in the barn
be deed restricted as a CDU, and that an employee housing "impact fee" for one employee be paid as
mitigation for the one additional required bedroom of employee housing. These restrictions would not
preclude future application for a free market single family home on the parcel, but their floor area would
be included in the ultimate floor area permitted on the parcel. The agricultural portions of the barn are
exempt from floor area to the extent applicable at the time of building permit submittal for a new
residence.
7. The BOCC finds that this amended proposal will provide appropriate mitigation for the failure of the
previous owner to provide the required housing mitigation.
NOW, THEREFORE, BE IT RESOLVED by the BOCC that it does hereby grant approval for a
minor amendment to a development permit for the 100 East River Ranch Road property to deed restrict the
existing two bedroom freestanding residence of approximately 1,244 square feet as an "employee dwelling
unit", to place a caretaker dwelling unit deed restriction on the existing accessory unit in the barn, and to pay
an employee housing mitigation fee for one employee, subject to the following conditions, which shall run
with the land and be binding on all successors in interest:
RECEPTION#: 686319,12/2212011 at
02:25:33 PM,
1 OF 5, R $0.00 Doc Code RESOLUTION
Janice K. Vos Caudill, Pitkin County, CO
Resolution No.,11S -2011
Page 2
1. The Applicant shall adhere to all material representations made in public meetings and in the application
and in the amendments to the application.
2. Within 90 days of this approval the Applicant shall submit building permits as required for the proposed
"EDU" and CDU, which permit applications may include associated barn improvements.
3. Within 90 days of this approval, the Applicant shall submit for review and approval of the County
Attorney and Community Development a Caretaker Dwelling Unit deed restriction for the unit in the
barn meeting all current terms and conditions for such deed restriction. The unit will be inspected by the
Housing Office for compliance prior to recording the deed restriction.
4. Within 90 days of this approval, the Applicant shall submit for review and approval of the County
Attorney and Community Development an "Employee Dwelling Unit" deed restriction for the two
bedroom primary residence. The unit will be inspected by the Housing Office for compliance prior to
recording the deed restriction.
5. Within 90 days of this approval the Applicant shall submit to the County $38, 902.53 in employee
housing mitigation for one employee.
6. The mitigation fee shall not be considered to be an "offset" in any way for any other Housing Impact fees
or other fees that may be required as part of the overall redevelopment of this property.
7. No new land use applications or building permits will be accepted for this property unless and until the
deed restrictions for the CDU and "EDU" are approved and recorded, the building permits for the CDU
and `EDU" are issued, and the CDU and "EDU" are completed and accepted for occupancy by the
Housing Office. However, a building permit application for the CDU may include other improvements to
the barn to be undertaken as part of any CDU renovation project.
8. The Applicant, by virtue of the deed restrictions put in place on the two-bedroom unit as an "EDU" and
the unit in the barn as a CDU, and the payment of the mitigation fee referenced in #5 above, has satisfied
the employee housing mitigation requirements currently applicable to the property and has retained the
ability to tender an application in the future which may contemplate the provision of a third residential
structure which will serve as the primary residence of the property.
9. The floor area of the two accessory units will be included in the total allowed floor area on the parcel.
The floor area of the agricultural portions of the barn will be exempt from the total allowed floor area on
the parcel to the extent applicable at the time of building permit submittal for the new residence. It is
understood and agreed that the third residential unit (new free market unit) will require approval through
and must meet the standards of all applicable land use and building permit processes at the time of
application. Use of TDRs for additional floor area may be permitted on the parcel subject to all required
approvals and standards in effect at the time of application.
10. The CDU shall:
a. Not exceed 1,000 net livable square feet;
b. The floor area of the unit shall be included in the total allowed floor area on the parcel;
c. One off street parking place shall be provided for the unit;
d. The kitchen must contain at minimum a two burner stove with oven, standard sink, and a
refrigerator plus freezer. The oven must be able to bake and broil and be at least 5 cubic feet. The
sink must measure at least 14"WX 16"DX5.25"H. The refrigerator must be at least 5.3 cubic feet
and must include a.73 cubic foot freezer.
Resolution N6.115--2011
Page 3
e. Have floor plans approved by Housing and Zoning;
f. Be inspected for compliance prior to certificate of occupancy/completion.
11. Failure to comply with the conditions of this approval may result in revocation of this approval, or any
subsequent permits or approvals related to this property, or vested rights associated with this property.
Resolution'No. 11Y-20
Page 4
APPROVED AND ADOPTED on the q day of , 2011.
le Jones
to the BOCC
APPROVED AS TO FORM:
John Ely,
County Attorney
PID #246725200001
P049-11
lancecfdanger main edu removal reso.doe
BOARD OF COUNTY COMMISSIONERS
OF PITKIN COUNTY, COLO
By
R chel E. Richards, Ch irwoman
Date /-�' ^ ,:P 6�11
APPROVED AS TO CONTENT:
vu PCQ
mdy Houben,
Community Development Director
EXHIBIT A
Order Number: 926058
LEGAL DESCRIPTION
FEE:
A parcel of land situate in Tracts 70 and 72, Sections 25 and 26, Township 8 South, Range 86
West of the 6th Principal Meridian being more particularly described as follows:
Beginning A P 8 of Tracts 71, thence N 86 degrees 22 minutes 07 seconds E 999.65 feet along
line 8-7 of said Tract 71 of said Township and Range;
thence S 16 degrees 08 minutes 33 seconds W 1150.00 feet;
thence N 90 degrees 00 minutes 00 seconds'W 650.37 feet;
thence S 00 degrees 08 minutes 06 seconds W 389.82 feet; II
thence N 74 degrees 25 minutes 43 seconds W 31.12 feet;
thence N 00 degrees 08 minutes 06 seconds E 1422.81 feet To The Point Of Beginning.
TOGETHER WITH that portion described in Deed recorded De' ember 5, 1991 in Book
663 at Page 730 as Reception No. 339198.
AND EXCEPT that portion described in Deed recorded December 5, 1991 in Book 663 at Page
726 as Reception No. 339197. j
Said property is also known as
PARCEL B,
RIVER ROAD RANCH CO./ GIBBONS LOT LINE ADJUSTMENT,
according to the Plat recorded in Plat Book 27 at Page 81.
i
And also described as follows:
i
A parcel of land situate in Tract 70 and 71, Section 25, Township 8 South, Range 86 West of the
6th Principal Meridian being more particularly described as follows:
i
Beginning at AP 8 of Tract 71, Section 25, Township 8 South, Range 86 West of the 6' Principal
Meridian,
thence N86°22'07"E a distance of 999.65 feet along line 8-7 of skid Tract 71 of said Township
and Range;
thence S 16°08'33"W a distance of 1696.30 feet;
thence N74'08'1 4"W a distance of 182.95 feet;
thence N75°12'43"W a distance of 365.50 feet;
thence N00°08'06"E a distance of 1422.81 feet To The Point Of Beginning.
EASEMENT:
The Perpetual Easement for access and utilities which is contained in the Access and Utilities
Easement Agreement recorded June 16, 2010 as Reception No. 570613 and re-recorded February
03, 2011 as Reception No. 577409.
LICENSE RIGHTS:
The Rights of Ingress and Egress as contained in the Access
02, 2011 as Reception No. 5 7803 1.
COUNTY OF PITKIN, STATE OF COLORADO
Order Number: 926058
Attached Legal Description
Page 1 of 1
Agreement recorded March
ADMINISTRATIVE DECISION OF THE COMMUNITY DEVELOPMENT DIRECTOR OF
PITKIN COUNTY, COLORADO, APPROVING THE BARRY-WEHNIILLER GROUP, INC.
ACTIVITY ENVELOPE
Administrative Determination NopZ 2012
RECITALS
1. Barry-Wehmiller Group, Inc ("Applicant") has applied to the Community Development Director of
Pitkin County ("Director") to establish an activity envelope for existing development , improvements to
that development, and potential future development of the site (subject to further site plan review).
2. The parcel is located at 100 East River Ranch Road, and is more specifically described in Exhibit A.
PID#2467-252-00-001. The parcel is 26+/- acres, and is conforming in the AR -10 zone district.
3. The parcel is subject to BOCC Resolution No. 115-2011, related to an EDU, a CDU, and further
development.
4. The Director finds that the proposed activity envelope is consistent with the applicable requirements of
the Code, as follows:
A. The Activity Envelope is primarily located on slopes of less than thirty (30) percent.
B. The parcel is generally in an area of alluvial fan deposits. Consulting Geologist, Nick
Lampiris, opined in 1986 that the site was not an active alluvial fan, and that rockfall and
heavy runoff would not reach the development area.
C. The wildfire hazard is rated as low to moderate on the parcel, and can be mitigated pursuant
to the provisions of Sec. 7-20-60(c) of the Code.
D. The parcel contains mapped elk and mule deer winter ranges above the ditch and power
lines. As all development is proposed below the ditch; impacts on wildlife can be mitigated
pursuant to Sec. 7-20-70 of the Code.
APPROVED by the Director, subject to the following conditions, which shall run with the land and be
binding on all successors in interest:
1. The Applicant shall adhere to all material representations made in the current or prior applications
and shall consider those representations to be conditions of approval, unless amended by other
conditions.
2. All conditions of BOCC Resolution No. 115-2011 shall remain in full force and effect unless
specifically amended herein.
3. Prior to submission of any building or other development permit applications (other than related to
the existing barn, CDU, and EDU), the Applicant shall be required to submit for approval an
application for Site Plan Review, pursuant to Sections 2-30-20 and 7-10-50 of the Code. Approval of
this Activity Envelope does not ensure approval of Site Plan review. The Site Plan Review application
shall address the following, in addition to the other requirements specified above:
RECEPTION#: 589156, 05/17/2012 at
11:14:19 AM,
1 OF 9, R $0.00 Doc Code ADMIN
DECISION
Janice K. Vos Caudill, Pitkin County, CO
L
A. Demonstrate compliance with the standards in Sec. 7-20-120.d for development within the
Scenic View Protection Area and the rural character guidelines for building location in Sec.
7-20-120.e of the Code.
B. Demonstrate that the site can accommodate any necessary on-site wastewater treatment
systems (OWTS) that comply with the then current OWTS regulations.
C. Demonstrate that a driveway can be constructed in compliance with the County and Basalt
Fire Protection District's driveway standards.
4. Prior to submission of the Site Plan Review application, the Applicant shall be required to submit for
approval by the County Attorney and Community Development Director an Activity Envelope Plan
in accordance with Land Use Code Section 2-30-20(g) and Application Manual Section 2.1.1. The
above referenced approvals shall be a condition precedent to finalization and recordation.
5. Prior to issuance of a Building Permit for any additional residence (other than the CDU and EDU), the
Applicant shall:
A. Provide proof of an adequate and legal water supply (in terms of quantity and availability) for
domestic and fire protection purposes for all units, and for irrigation purposes, as applicable, to
the Environmental Health Department, as such factors relate to an adequate and sustainable
water supply.
B. Obtain necessary on-site wastewater disposal system permit (s) from the Environmental
Health Department.
C. Obtain a fireplace/woodstove permit from the Community Development Department, if
necessary.
D. Submit a site specific, detailed drainage and erosion control plan prepared by a qualified
engineer or geologist for review and approval by the Planning Engineer. The plan shall
address the drainage in the area where the existing dwelling units are located. All historical
drainage patterns shall be maintained.
E. If the project disturbs more than one acre, a State Stormwater Permit shall be obtained prior to
permit issuance.
F. Pay the applicable road and employee housing impact fees.
G. Submit a detailed construction management plan which addresses all phases of construction
for review and approval by the Planning Engineer.
H. Apply for and obtain a variance from any and all setback requirements, if required.
1. Submit a detailed re -vegetation plan for review and approval by the Community Development
Department. The plan shall include at minimum:
1) A tree mitigation plan for the removal of all trees six (6) inches or larger in diameter at
breast height (DBH).
2) A management plan for noxious weeds on the parcel by means of an Integrated Weed
Management strategy according to the current Pitkin County Weed Management Plan.
J. Submit for and obtain an approved Access Permit for the driveway, which shall be built to
current County standards, as described in the Pitkin County Asset Management Plan and
approved by Planning /Zoning.
Administrative Decision N6.96 -2012
Page 2
6. No new structural development in excess of thirty (30) inches above or below natural grade shall
occur within the setbacks of the lot, with the exception of driveways and associated retaining walls of
up to six (6) feet above or below natural grade and fencing. Landscaping in the form of berms shall
not exceed four (4) feet from the most restrictive grade. Any development located within setbacks
mandated by County zoning regulations that does not comply with these restrictions shall require a
variance from the Board of Adjustment. Approval of an activity envelope within such setbacks does
not assure approval of a variance.
7. The Applicant shall comply with the following standards, to mitigate for Development on the parcel
which is mapped overall as a Low to Moderate Wildfire Hazard Area:
A. Defensible Space: The area around all buildings/structures, limited by property boundaries
that may limit a property owner's ability to comply with this section, shall incorporate
landscaping with wildfire defensible space considerations as follows (note: actual
vegetation manipulation to meet these conditions may not be necessary where the natural
vegetation patterns have already fulfilled these conditions):
1) Brush, debris and non -ornamental vegetation shall be removed within a minimum ten (10)
foot perimeter around all structures.
2) Vegetation shall be reduced to break up the vertical and horizontal continuity of the fuels at
a minimum of a thirty (30) foot perimeter around a structure built on flat ground.
3) Spacing between clumps of brush and vegetation up to the thirty (30) foot perimeter shall
be a minimum of two (2) times the height of the fuel. Maximum diameter of the clumps
shall be equal to the height of the fuel. All measurements shall be from the edges of the
crowns of the fuel.
4) All branches from trees and brush within the thirty (30) foot perimeter shall be pruned to a
height of ten (10) feet above the ground with removal of ladder fuels from around trees and
brush.
5) Tree crown separation within the thirty (30) foot perimeters shall have a minimum of ten
(10) feet between the edges of the crowns, except for mature stands of aspen trees where
ladder fuels have been removed. In areas of aspen regeneration, understory shrubs and
down and dead materials shall be removed.
6) All branches that extend over the roof eaves shall be trimmed and all branches within
fifteen (15) feet of chimneys shall be removed.
7) All deadfall up to a one -hundred (100) foot perimeter shall be removed.
8) No new conifer trees shall be planted within ten (10) feet of a residence.
9) No flammable mulches shall be placed within two (2) feet of a residence.
10) The property owner shall be responsible for the continued maintenance of the defensible
space vegetation requirements.
B. Access:
1 Access roads and driveways shall be built to County standards; however, these standards
may be increased to mitigate wildfire hazards based on comments provided by the
Colorado State Forest Service, the Sheriff's Department, local fire protection districts
and/or a person approved by the County as an expert in wildfire area designation and
Administrative Decision NoC�L6 -2012
Page 3
s-�
mitigation. Where feasible, looped routes of access/egress to a public road shall be
incorporated in the design of a proposed development. Looped routes of access/egress is
defined as two (2) or more dedicated access roads to the main artery/highway for widely
separated ingress/egress; looped drives with one (1) entrance point or divided single
entrances do not satisfy this condition. Where this is not feasible, the Community
Development Department may approve vehicular turnaround areas a maximum of seven
hundred fifty (750) feet apart installed between the road intersection and its terminus.
2) Turnaround areas shall be the same standards as cul-de-sac turnaround pads; these may be
incorporated into the proposed driveway entries.
3) New dead-end streets shall not be permitted, except for cul-de-sacs and other turnarounds
accepted by the applicable local fire department.
4) Cul-de-sac turnaround pads shall have a minimum thirty (30) foot drivable surface inside
turning radius or a hammerhead or other T -area acceptable to the applicable local fire
district.
5) New driveways and access roads shall enter the roadway at a ninety -degree (90°) angle for
the first twenty-five feet of the driveway.
6) Fuel breaks as recommended by a wildfire expert approved by the County may be
incorporated into the design of access roads or driveways.
C. Water Supply for Fire Safety:
1) When access to a public or private pressurized water system is not available or if it is
necessary to augment fire protection water systems, private ponds may be used if approved
by the County Community Development and the local fire district.
2) Any fire department recommendation for individual structure for water supply and storage
shall be accessible to fire department vehicles from the exterior of the structure through a
fire department approved mechanism (such as a fire hydrant). The- amount of storage
capacity shall be determined by the fire protection district with a minimum of one thousand
(1,000) gallon storage capacity per structure.
3) All structures greater than five thousand (5,000) square feet in size shall be required to
install in-house sprinkler systems that meet the standards of the local fire protection district
and the IBC. At building permit submittal, the local fire department may require smaller
structures to be sprinkled due to hazard considerations, emergency access difficulties and
lack of proximity to fire protection services.
D. Roofing Materials, Roofing Vents and Projections At and Below Roof Line:
1) Roofing Materials:
(a) Class A covering or Class A assembly as defined by the currently adopted Building
Code.
(b) No wood shakes or shingles.
2) Roof Venting:
(a) Soffit venting shall be located in the outer 1/3`d portion of the overhang.
Administrative Decision No�-2012
Page 4
C C
(b) Attic, soffit and other roof venting shall be of non -corrosive metal mesh with
maximum '/4" openings.
3) Projections at the Roofline, including Soffits, Rafters, Porch or Deck Roofs, Fascias, or
Other:
(a) Sheath with non-combustible materials, or
(b) Combustible material underlain with 5/8" Type X gypboard or equal, or
(c) Minimum 4x6 rafters with 2x T&G decking.
4) Decks, Decking, Cantilevered Floors, or Other Projections below the Roofline:
(a) Minimum 6x6 posts, 6x10 beams, 3x8 joists, 3x decking, and 2x railing, or
equivalent log construction.
E. Roofs with less than a 3:12 pitch are not permitted unless they comply with the following:
1) All roof coverings shall be constructed of non-combustible materials and installed on a
Class A roof assembly.
2) All roof coverings shall have a surface that shall facilitate the natural process of clearing
roof debris.
3) Protrusions above the roofline, such as parapets, shall be prohibited.
4) Roofs shall be installed as required by the adopted Building Code and shall have a
minimum pitch of 1:48.
5) All roof designs, coverings, or equivalent assemblies shall be specifically approved by the
Fire Marshal prior to submittal of a building permit application.
F. Maintenance and Miscellaneous Requirements
1) Roofs and gutters shall be kept clear of debris.
2) Any outbuilding shall adhere to the same wildfire requirements.
3) Yards shall be kept clear of all litter, slash and flammable debris.
4) All flammable materials shall be stored indoors or on a parallel contour a minimum of
fifteen (15) feet away from any structure.
5) Weeds and grasses within the ten (10) foot perimeter shall be maintained to a height not
more than six (6) inches.
6) Firewood/wood piles shall be kept indoors or stacked on a parallel contour a minimum of
fifteen (15) feet away from the structure.
7) Swimming pools and ponds shall be accessible by the local fire district.
8) Fences shall be kept clear of brush and debris.
9) Wood fences shall not connect to other structures.
10) Fuel tanks shall be installed underground with an approved container.
Administrative Decision No.�-2012
Page 5
11) Propane tanks shall be buried, if possible, or installed according to NFPA 58 standards
and on a contour away from the structure with standard defensible space vegetation
mitigation around any aboveground tank. Any wood enclosure around the tank shall be
constructed with materials approved for two (2) hour fire -resistive construction on the
exterior side of the walls.
12) Each structure shall have a minimum of one ten (10) pound ABC fire extinguisher.
13) Addresses shall be clearly marked with two (2) inch non-combustible letters and shall be
visible at the primary point of access from the public or common access road and installed
on a non-combustible post.
14) All utilities shall be extended underground.
15) Additional recommendations from the Colorado State Forest Service, the Pitkin County
Sheriff's Office, the local fire protection district and/or a person certified by the
Community Development Department as an expert in designation of wildfire areas and
wildfire mitigation may be incorporated into any conditions of approval as necessary to
mitigate wildfire hazards.
The Applicant shall comply with the applicable codes and requirements of the Basalt Fire Protection
District, including but not limited to access with a minimum width of sixteen (16) feet, with an all-
weather surface capable of handling the imposed loads of a 60,000 pound fire apparatus, turning around
of fire apparatus, installation of an approved fire sprinkler system and alarm system (if the structure
exceeds 5,000 square feet) and provision of water supply for fire fighting. The water supply shall be a
minimum of 20,000 gallons of year round reliable supply that will serve both the fire suppression system
and dry hydrant assembly such that a fire department pumper truck can access it.
9. The Applicant shall comply with the following standard measures to mitigate impacts to wildlife:
A. When existing native vegetation must be altered within the Activity Envelope, the
Applicants may be required to prepare a habitat mitigation plan acceptable to the County.
Such mitigation plan may substitute (in a nearby area on the subject property) vegetation
equal in type and quantity to that being removed to mitigate effects on wildlife species.
Should there be no opportunity on the property for habitat mitigation or restoration, off-site
mitigation benefiting the same species may be required, or financial mitigation may be paid
into a County habitat mitigation fund should such a fund be established in the future.
B. Non- agricultural manipulation of vegetation outside of the Activity Envelope is prohibited.
Native vegetation shall be preserved outside the approved Activity Envelope.
C. Mesh or woven wire fences are prohibited outside the Activity Envelope.
D. Wood rail fencing shall employ three (3) rails or less, be the round or split rail type, shall
not exceed fifty-four (54) inches in height above ground level, and twelve (12) inches in
width (top view), and shall have at least eighteen (18) inches between the lower two (2)
rails.
E. Wire fencing must be three (3) strands or less. The top wire should be a twelve -point -five
(12.5) gauge twisted barbless type at a maximum height of forty-two (42) inches. The
middle strands (which may be barbed) should be located a minimum twelve (12) inches
apart and from the top wire preventing entanglement when mule deer jump over. The
bottom strand should be sixteen (16) inches from the ground.
Administrative Decision NoC-2012
Page 6
F.
F. Tall overly mature trees and standing dead trees (snags) shall be retained at the rate of two
(2) to five (5) per acre whenever possible as nesting and perching habitat.
G. In areas of high black bear activity, fruit bearing trees and shrubs shall be prohibited within
the activity envelope. This does not include pre-existing native trees and shrubs.
H. Development shall be clustered to the maximum extent possible to minimize impact on
wildlife.
I. Access shall be provided to the Colorado Division of Wildlife for trapping, tagging,
studying, or otherwise managing wildlife.
J. Trash/garbage shall be kept in an approved bear resistant container or enclosure. These
containers shall be accessible to and used at all times by contractors on site.
K. Horse grains, pellets, and cookies shall be stored indoors and or/in bear resistant containers.
L. All outside doors shall utilize only solid round handled doorknobs unless another type is
required by the applicable Building Code for disabled accessibility purposes.
M. Bird feeders, including hummingbird feeders, shall be hung away from any deck or
window, and be at least ten (10) feet from the ground suspended between two (2) trees or
posts. All seed feeders shall include a seed catchment pan to catch discarded seed.
N. Pet food shall not be left outside.
O. Dogs shall be kenneled within fifty (50) feet of the residential buildings or leashed under
human supervision when outside a required kennel.
P. Contractors are not allowed to bring dogs on site.
Q. High impact recreational uses are prohibited.
10. No development including grading, excavation, fill placement, berms, landscaping, vegetation removal
or disturbance, well or septic system shall occur outside of the approved activity envelope, except as
necessary for weed management or to comply with the wildfire mitigation measures described above.
11. Prior to commencement of any earthmoving or other construction activity, the Applicant shall stake
the corners of the activity envelope and install orange safety fencing around the construction site
within the perimeter of the activity envelope to prevent any unnecessary vegetation disturbance
during construction. The fencing shall remain in place until issuance of a Certificate of Occupancy.
12. All areas disturbed by construction shall be re -vegetated with native shrubs and grasses according to
the Pitkin County Revegetation Guideline and within one growing season of the project's completion.
13. No calculations for height, bulk, setback, size, floor area, or any other building and zoning requirements
have been conducted. These requirements will be considered at the time of building permit.
14. The Applicant has been informed by Pitkin County of the existence of environmental hazard areas that
might affect the property, any improvements, and the use and occupancy thereof. The provisions of
the Pitkin County regulations do not in any way assure or imply that areas outside of designated
hazard areas will be free from hazards, or that approved mitigation measures will guarantee the safety
of any property.
15. Failure to comply with the conditions of this approval may result in revocation of this approval, or
any subsequent permit(s) or approval(s) related to this property, or vested rights associated with this
property. ff��
Administrative Decision Noo9g -2012
Page 7
16. Statutory vested rights for the approval contained herein are granted pursuant to the Pitkin County
Land Use Code and Colorado Statutes, subject to the exceptions set forth in Pitkin County Land Use
Code, § 2-20-170 and C.R.S., § 24-68-105. The statutory vested rights granted herein shall expire on
May J 2015.
PUBLISHED AFTER ADOPTION FOR VESTED REAL PROPERTY RIGHTS in the Aspen Times
Weekly on the c�L4 day of (i'l 2012.
APPROVED by the Director, this day of May, 2012.
Cindy Houben,
Community Development Director
PID# 2467-252-00-001
P023-12
rWy
Administrative Decision No. 9(o-2012
Page 8
ENIMIT A
Order Number: 926058
LEGAL DESCRIPTIO:
FEB:
A parcel of land situate in Tracts 70 and 72, Sections 25 an
West of the 6th Principal Meridian being more particularly
8 South, Range 86
[lows:
Beginning A P 8 of Tracts 71, thence N 86 degrees 22 minutes 0 seconds E 999.65 feet along
line 8-7 of said Tract 71 of said Township and Range;
thence S 16 degrees 08 minutes 33 seconds W 1150.00 feet;
thence N 90 degrees 00 minutes 00 seconds'W 650.37 feet;
thence S 00 degrees 08 minutes 06 seconds W 389.82 feet;
thence N 74 degrees 25 minutes 43 seconds W 31.12 feet;
thence N 00 degrees 08 minutes 06 seconds E 1422.81 feet To The Point Of Beginning.
TOGETHER WITH that portion described in Deed recorded De. ember 5, 1991 in Book
663 at Page 730 as Reception No. 339198.
AND EXCEPT that portion described in Deed recorded Decemb 5, 1991 in Book 663 at Page
726 as Reception No. 339197.
Said property is also known as
PARCEL B,
RIVER ROAD RANCH COJ GIBBONS LOT LINE AD.'
according to the Plat recorded in Plat Book 27 at Page 81.
And also described as follows:
A parcel of land situate in Tract 70 and 71, Section 25, Township 8 South, Range 86 West of the
6th Principal Meridian being more particularly described as follolvs:
Beginning at AP 8 of Tract 71, Section 25, Township 8 South, Range g 86 West of the 61, Principal
Meridian,
thence N86°22'OT'E a distance of 999.65 feet along line 8-7 of s said Tract 71 of said Township
and Range; j
thence S 16'08'33"W a distance of 1696.30 feet;
thence N74'08'14"W a distance of 182.95 feet;
thence N75°12'43"W a distance of 365.50 feet;
thence NOO'08'06"E a distance of 1422.81 feet To The Point Of Beginning.
EASEMENT:
The Perpetual Easement for access and utilities which is contained in the Access and Utilities
Easement Agreement recorded June 16, 2010 as Reception No. 50613 and rc-recorded February
03, 2011 as Reception No. 577409.
LICENSE RIGHTS:
The Rights of Ingress and Egress as contained in the Access License Agreement recorded March
02, 2011 as Reception No. 578031.
COUNTY OF PITKIN, STATE OF COLORADO
f
order Number. 926058
Attached Legal Drsciption
Page I of 1
[
ZYK b14 A
Az
Z
N
Y'RO
Pillsbury Parcel
19�� 41 Basis of Bearing— N00°08'06"E
---F----------------------------
/ / / .,-,n Natural GasRec
i d m /
0
50' Right of
R /
W ailro
O
Rocky Mountain Natural Gas
/ Ditch Book 2A Page 271
n /
S /
Qm /
1 / /
r /
EXISTING ROAD
TO REMAIN
SEPTIC FIELD: K
SHACK AND AG
BARN
REMOVE EXISTING
GRAVEL DRIVE
AREA OF D15TUR5
ANCE-
3 1.600 5F
Parcel B / XISTING MULE
SHED
26.953 acres ±
S
1696.30,
1
0
I
I
1422.81'
�
w,
II\rl /
29
°a
/
Q
m
/
,
U
�
Q
/
/
W
=
U
Z
O
o
Q
O
>o
rr^^
vJ
6
W
C)
O
z
/
/
DRAINAGE AND EROSION CONTROL REQUIREMENTS
THERE ARE NO POTENTIAL WATERCOURSES AFFECTED BY
5TORMWATER RUNOFF.
AREA OF DISTURBANCE 15:5&,100 5F.
PROVIDE HAY BALES AND SEDIMENTATION FENCE AT
PERIMETER Of AREA OF DISTURBANCE
ALL DISTURBED AREAS ARE TO BE RESEEDED WITH
NATIVE SPECIES AND/OR PITKIN COUNTY APPROVED SEED
MIX.
ONSITE WATER MANAGEMENT PLANS: HISTORIC, DRAINAGE
PATTERNS WILL BE MAINTAINED TO ALLOW WATER TO
INFILTRATE.
� N
I CO N
O O
I m
I
I
I
I
I
I
I
Found #5 Rebar 8
Yellow Plastic Cap
9.-- - — - --Q HEW CONTOUR Marked LS15710
-------- EXISTING CONTOUR TO BE REVI5ED
--- EXISTING CONTOUR
CEXISTING GRAVEL DRIVE TO BE REMOVED
EXISTING GRAVEL DRIVE TO REMAIN N
- NEW GRAVEL DRIVE
ARCHITECTURAL SITE PLAN /
Z
Q
m
U
�
Q
W
=
U
Z
O
o
Q
O
>o
rr^^
vJ
6
W
C)
O
z
/
/
Found #5 Rebar
/
-.Broken Red Plastic Cap
Mater Ld4AP018
S15°54'05"W44144
from NE Property Comei
Benchmark EN. 7060.06'
DRAINAGE AND EROSION CONTROL REQUIREMENTS
THERE ARE NO POTENTIAL WATERCOURSES AFFECTED BY
5TORMWATER RUNOFF.
AREA OF DISTURBANCE 15:5&,100 5F.
PROVIDE HAY BALES AND SEDIMENTATION FENCE AT
PERIMETER Of AREA OF DISTURBANCE
ALL DISTURBED AREAS ARE TO BE RESEEDED WITH
NATIVE SPECIES AND/OR PITKIN COUNTY APPROVED SEED
MIX.
ONSITE WATER MANAGEMENT PLANS: HISTORIC, DRAINAGE
PATTERNS WILL BE MAINTAINED TO ALLOW WATER TO
INFILTRATE.
� N
I CO N
O O
I m
I
I
I
I
I
I
I
Found #5 Rebar 8
Yellow Plastic Cap
9.-- - — - --Q HEW CONTOUR Marked LS15710
-------- EXISTING CONTOUR TO BE REVI5ED
--- EXISTING CONTOUR
CEXISTING GRAVEL DRIVE TO BE REMOVED
EXISTING GRAVEL DRIVE TO REMAIN N
- NEW GRAVEL DRIVE
ARCHITECTURAL SITE PLAN /
Z
Q
m
U
�
Q
W
=
U
Z
O
o
Q
O
>o
rr^^
vJ
6
W
C)
O
z
BUILDING PERMIT
m«mrrom..nm." mm.n�.nx.ev�A�
PROJECT NO:
DRAWN BY: JS
CHECKED BY: MF
ISSUE DATE:
PLOT:
ARCHITECTURAL SITE PLAN
R
' i
AS101
E
BO • 301 30 -i __ ..._.
MAIN LEVEL
FLOOR PLAN
SCA.IF "'B"= i'0"
Z
MQ
W
U Q
Q
Z O
U Q
Z
W 12�
z Er
O >_�
SSS
U S
0 Q
wP w O
LL V)
11 BUILDING PERMIT
mu q mex arevwnq• vim vpxx�xvumv
.Meoxx mmmoutm M' p Nixionrtmo-n
F� All
PROJECTNO:
DRAWN BY: J5
CHECKED BY: MF
ISSUE DATE:
PLOT:
jonclumumm
MAIN LEVEL PLAN
oft mk t
1. FIELD VERIFY ILL
IN WRITING, OF ALL DISCREPANCIES.
-
1
90 301 30
LOFT LEVEL FLOOR PLAN
SCALE. 3/16 7 TZ \ f
low
BUILDING PERMIT
a a..Nne. a..s.....s•m.m...a q.m
Mme q me+. a�.wny..m apcutaaam
P.PM.na eopY�gm mm.A��men
we N �r m.. pmon %en�er:wk m�
k�+
e�ouyrtm�me.tlamion aamaA M�Ilsn p p�
PROJECT NO:
DRAWN BY: JS
CHECKED BY: MF
ISSUE DATE:
PLOT:
uI
LOFT LEVEL PLAN
N
A102
r
a
JUCK
bow SCHEDULE i - m, - '' -
�Q � IN WPoTING, OFALLdSCREPANGES.
{- =-� {'—�--�1` {�-4 �` X0' F j T ,'--i' {---5' { 4-0 2 INSTALLCARBONMONOXIDEDETECTORS.CENIRALLYLOCATEDOUfSIDEOFEACH
TE SLEEPING AREA IN THE IMMEDIATE VICINITY OF
OF
❑ T
i[0 • 9. INST1SEE� SMOKE DETETION 8.15.1 D CT PER 2009 DETECTORS, ASPREMUFD4CIPAMCODE FOR
PING ROOMS.
GREbb
001 ® ® ® ® Q OO 010 4. REFER TO STRUCTURAL DRAWINGS FOR REINFORCING REQUIREMENTS TO EXISTING STIiUCTURAL
® MEMBERS.
- q•-0• 5. HANO REPAIR SUT FAC TU
FINISHES dSRBED BY STRUCTURAL WORK TO MATCH
MANDOW SCHEWLE NOTES PPATOATCAIR INNGADM RFACEb.
�. ALLWIFIDOWS TO HAVEAUFACTOR OF 35 MAX B.
EXTERIOR WALL SCONCES TO BE THE ARTESIA"B'Ab MANUFACTURED BORN LIGHT ELECTRIC.
ll ■ IX4ANDAS OF .De
FIELDVEPoFYALLN ENSIGNS
REPIACE EXISTING WINDOW TRIM d BASEBOARD WITH
EI1X/AS REQ'EQ'D.
011 012 Oi 014 015
ROOF PLAN
SCALE: 114 = 1'-0" L
FLOOR PLAN
Y
U
Q
2
U)
w
2
H
2
Z
O
Z
w
Z W
o
E
co
LU
w
BUILDING PERMIT
O
0
O
J
O
U
}
z
Z
Z)
O
U
z
Y
H
a
neq m.,o mw.�pa.ia apecmevenna
P° P.M era mpyrreN a nx Ar=mm�
aNM mr
PROJECTNO:
DRAWN BY: JRB
CHECKED BY: MF
ISSUE DATE:
PLOT; 07/24112
MAIN LEVEL AND ROOF
PLAN
A101
'I
O
2
p so
O '
GENERAL NOTE5:
PIELD VERIFY ALL EXISTING DIMEN510NS AND NOTIFY ARCHITECT.
IN WRITING, OF ALL DISCREFANCIE5.
I1,15TALL CARBON MONOXIDE DETECTORS, CENTRALLY LOCATED OUTSIDE OF EACH
�7
`
PERMIT
Friday, July 27, 2012
PROJECT NO:
DRAWN BY: EH
CHECKED BY: MF
ISSUE DATE: 727/12
PLOT: 727/12
MAIN LEVEL PLAN
AdE �
C
9 A102
Basis of Bearing
0
I
/
'QUICK -4' CHAMBER
/
/ TRENCHES. 25 CHAMBERS
/
/ PER TRENCH
125 CHAMBERS = 1235 SF
�� // w OBSERVATION PORTS
asement
atural
age 271
26.953 ac rl.
NOTE: HAIR TRAPS MUST BE PLACED
ON FLOOR DRAINS IN HORSE
STALLS
N00006'06"E
4" SDR -35 SEWER PIPE
WITH CLEANOUT
(2% SLOPE TO TANK)
1250 -GALLON,
TWO-COMPARTMENT
CONCRETE SEPTIC TANK
WITH EFFLUENT FILTER -
4" SDR -35 SEWER PIPE
(11% SLOPE TO FIELD) 100'
200'
DRAIN FIELD CROSS SECTION - TYP. INFILTRATOR(R) QUICK4(TM) CUT SHEET 4" PVC
52" OBERVATION
48" PIPE
4" PVC 11 (EFFECTIVE LENG )
OBERVATION34"
7-1 IiITi-=1�== _ - PIPE
-1L 12"
3.5' max UNDISTURBED II ll1
A
SOIL 2' min 16°
—6' min 12"liW
34"
LIMIT OF
LINES TO ENTER
EXCAVATION
GRAVELLESS'QUICK-4' LOW AND EXIT IN TOP
SCARIFY SURFACE PROFILE CHAMBER (4'x 3') PORT OF CHAMBER
END PLATE
PLAN VIEW - TYP.
K"
.-FLUENT PIPE
M SEPTIC TANK
'RIBUTION
_S PLACED IN
' PORT OF
AMBER END
TES
2 BEDROOM
RESIDENCE
W 4 HORSE STA S'
1250 -GALLON,
TWO-COMPARTMENT
CONCRETE SEPTIC TANK
WITH EFFLUENT FILTER
2 BEDROOM
RESIDENCE
0
a►
N
0' 50' 100'
Scale: 1" = 50'=0"
Found USGLO
2.5" Brass Cap on
Marked AP 8 Tract
Section 25, 1926
!IN,/_4"
SDR-35 SEWER PIPE
WITH CLEANOUT
(2% SLOPE TO TANK)
CV ,rrrr/rr/rr/,
•//rr/rrr/rrrr/r.
r r/rr/rrr/r/rr/rrr
W i'rii✓iiziiiiiiiiiii
,,rrrr/rr/rrrr//rr/rr///.
o
,rrrrrrrrr/rr/,rrrr/rr
,,,,,,,rrrrrrrrrrr/rr/rr/.
- rr//r/rr/rrrrrrrrrrri/rr/rr
rr/r//rr/rrrrrrrrrrrr/,'r/rr/
r/r//rr/rr/rr/rr/rr/rrrrrrrr//rr/
/irrrr/r//r//rr/rr/rr/rr/rrrr/.rrr/r
irr//,rrrr/rr/rr/rr/r/rrr/rr/rrrrrrrrr
r/ rr/,rrrr/rrrrrrr/r/,,,rrrr//r//rr/rr/,rrrr/rr
,,,rrr,/rr,rrr,rr,rrrrr„rrrr/rr/r/,
,,rrrr/rrrrrrrrrrrrrrr/rr,,,/rr
Septic Tank with the Addition of an Effluent Filter -1250 Gallon, 2 -Corp.
SLIP-ON PVC CAP Concrete Risers
DO NOT GLUE `\
ZAway
Ground
-undFINISHED m R
isers
GRADE
EFFLUENT LINE - 4” �_' _1 "_1' Filter Cartridge Handle
SCHEDULE 40 OR 4" SDR (field cut to desired height)
SEWER LINE - 35 P.U.C. Top of tee to come to
1" from top of tank lid Tank Adapter (cast or bolted)
4" SCHEDULE
Inlet Tee
40 P.V.C. vent Orifice
—
INSULATED COPPER TRACER uid Level Modulating Discharge Orifices
WIRE MAY BE INSTALLED TO
LOCATE LINE IN FUTURE Effluent Discharge
v
Liq
Z"
Vault Inlet Ports
DESIGN
4 -BEDROOM RESIDENCE = 600 Gallons
(75 gallons per day/person x 2 persons per bedroom)
4 HORSE STALLS = 100 Gallons
(25 gallons per stall)
TOTAL LOADING = q = 700 GALLONS PER DAY
PERCOLATION RATE = 36 MPI
CALCULATED AREA = ((1.5 X q) X sqrt 36 / 5) X 1.4 = 1764 SF
REQUIRED AREA = 1764 SF X 30% REDUCTION = 1235 SF
PROPOSED AREA = 125 CHAMBERS = 1235 SF
TRENCH SPECIFICATIONS
WIDTH OF TRENCHES = 3 FEET = 1 CHAMBER
LENGTH OF 'QUICK -4' TRENCHES = 100 FEET = 25 CHAMBERS
TOTAL NUMBER OF 'QUICK -4' CHAMBERS = 125
TOTAL INFILTRATIVE AREA= 1235 SF
FIVE TOTAL TRENCHES
ORENCO BRP
NOT ENFORC
BOX AND COVER BROUGHT TO GRADE
FINSHERGD RA 5E
CONCRETE LID 0000 1 \
OUTLETS
INLET
DISTRIBUTION BOX BAFFLE
Filter Cartridge
Effluent Filter