HomeMy WebLinkAboutpitkin.eh.264504404022 (1997) Fireplace Registration11sintedonRecycled PERMIT FOR FIREPLACE OR STOVE
Paper
� � 4
U �
Q �
Name of owner of property A66 f 1213 LC_
Owner's Mailing Address O L/ I/ �'�A-P 7b 11�-
Street Address of Property _So-fy\- E_
Legal Description of Property �`�* Z `/'�
Owner's Phone Number -1170- qa.7-'/2j Parcel ID# of Property (0 -Dq� -0 q- c�2
7',/- '7d'}' 9X71 Tax Schedule # of Property
C�L,6;�2— O -P,610
Structure type: Single Family 0
Commercial/Office Fl
Check one: New Construction
Duplex = Condo 0 Apt=
= Other
aRemodel
NUMBER & TYPES OF DEVICES YOU PLAN
TO INSTALL:
# OF CERTIFIED WOODSTOVES
MAKE, MODEL #
ROOM
CATALYST?
# OF FIREPLACES W/ GAS LOGS
ROOM(S)
# OF DECORATIVE NATURAL GAS FIRE
PLACE APPLIANCES W / 4" OR 5" CLASS
B VENT S
MAKE, MODEL #Qa �a;ro� CSC 3(Q t
ROOM(S)
# OF WOODBURNING FIREPLACES
ROOM
DOES THE FIREPLACE HAVE AN INSERT?
(yes / no) TYPE
# OTHER DEVICES TYPE
ROOM(S)
NUMBER & TYPES OF DEVICES YOU AL-
READY HAVE
# OF CERTIFIED WOODSTOVES
MAKE, MODEL #
ROOM
CATALYST?
# OF FIREPLACES W/GAS LOGS
ROOMS)
# OF DECORATIVE NATURAL GAS FIRE-
PLACE APPLIANCES (WITH 4" OR 5"
CLASS B VENT)
MAKE, MODEL #
ROOM(S)
# OF WOODBURNING FIREPLACES
ROOMS)
DOES: THE FIREPLACE CONTAIN AN
INSERT? TYPE
# OF OTHER DEVICES
ROOMS)
TYPE
If gas logs or a gas appliance are being installed in a bedroom, the Building Department re-
quires proof that the log or appliance is approved for installation in a bedroom by UL or
AGA and the man acturer:
Signature of applicant ADate Fee Paid 30
Environmental Hea tment approval—f Yl�a e I to 1 Date Paid lS
3Y2" and a width of 42". Framing
height varies for each fireplace. See
Figure 2.
The GC400 and GC421 will fit a rough
framed opening that has a depth of
23'/2" and a width of 48". Framing
height varies for each fireplace. See
Figure 2.
These dimensions represent the dis-
tance from stud to stud only and do
not take into consideration the addi-
tion of sheetrock/drywall.
The top header may touch the stand-
offs but the dimensions shown here
1" Mlin. air space
RgIFT 'prior to `unit
placement.
For best results, do not construct the
framing until the unit is in place.
A mantel may be placed a minimum of
42" from the base of the unit.
On direct vent models (GC300,
GC400), an operable window may be
constructed as low as 51— from the
base of the fireplace while a recessed
shelf or an inoperable window may be
constructed as low as 44"` from the
base of the unit. These dimensions
can only be obtained by using a TB2
low clearance vent kit.
`These dimensions can only be obtained
ure 2 by using a T132 low clearance vent kit.
I
51 "'
Min. window
height;
44"" Min.
i recessed
shelf or the
frame of
an inoperable
window
•2" in. height
i �
Model A B
GC300
383/4"
42"
GC361
419/16"
42"
GC400
383/4"
48"
GC421
419/16"
48"
Figure 4 All dimensions
GC361, GC421 Outer flue
are in inches. 8" diameter
D�--C
3715/16"
35" 23"
41/16" ,i///////� 2011hs" E
t
ctrical
ckouts
Gas line 42" Min.
knockout
6" mantel
25/&" height
16 �43/4-I
Model
A
B
C
D
E
GC300
36"
41"
241/2"
111/4"
113/4"
GC361
36"
41"
241/2"
91/2"
131/2"
GC400
42"
47"
301/2"
111/4"
113/4"
GC421
42"
47"
301/2"
11"
12"
meet proper clearances to com-
bustible sidewalls. Minimum clear-
ances from the fireplace metal to
combustibles are: top of standoffs -
0"; floor - 0"; back - V"; sides - Y2";
ceiling - 30". Figure 3 illustrates the
proper clearances.
These dimensions represent the dis-
tance from stud to stud only and do
not take into consideration the addi-
tion of sheetrock/drywall.
The GC300 and GC400 are certified
for installation in bedrooms, bed/sitting
rooms and mobile homes under most
major building codes. The GC361 and
GC421 are certified for installation in
bedrooms and bed/sitting rooms.
Consult local building codes for local
installation and operational guidelines.
A hearth extension is not required.
GC300, GC400
k-1
rical
I42" Min.kout
mantel
height
I 1
-� 7" 35/6" /16„
The following figures .are the maxi- (�
mum distances from the base of
the unit, and the minimum air
space clearances that must be
maintained when vertically venting
the GC300 or GC400: Maximum
straight unsupported rise - 25'; air
space clearances around vertical
venting - 1" on all sides; maximum
height - 40' from the base of the
unit; minimum height - 12'.
Every 1' of horizontal run requires
at least 2' of vertical rise (example:
a 12' overall installation height may
GAS'
VENT
LOWEST DISCHARGE
OPENING
2 X
ROOF PITCH
IS X/12 INCHES
H (MIN.) -MINIMUM HEIGHT
FROM ROOF TO LOWEST
DISCHARGE OPENING
(See Chan A) Figure 5
40' of vertical rise).
Chart A
Roof Pitch H (Min.) Ft.
Flat to 6/12
1.0
6/12 to 7/12
1.25
Over 7/12 to 8/12
1.5
Over 8/12 to 9/12
2.0
Over 9/12 to 10/12
2.5
Over 10/12 to 11/12
3.25
Over 11/12 to 12/12
4.0
Over 12/12 to 14/12
5.0
Over 14/12 to 16/12
6.0
Over 16/12 to 18/12
7.0
Over 18/12 to 20/12
7.5
Over 20/12 to 21/12
8.0
Note: Any horizontal run of vent
must have a 1/4" rise for every 1'
be offset as much as 0 horizontally. Major building codes specify a min- of run towards the termination.
The maximum horizontal run is 20' imum chimney height above the Never allow the vent to run down -
when combined with the maximum roof top. See Figure 5 and Chart A. hill. This will cause a fire hazard.
Horizontal Direct Venting
The HEATILATOR top direct vent • Required rise: 1/4" for every 1' of soffit and 651/4" minimum to
design of the GC30CI and GC400 horizontal run. unventilated soffit with a stan-
allows venting horizontally through . Required vent supports (horizon- dard horizontal installation; 63"
the wall, vertically through the roof, tal runs): one support very 3' minimum to ventilated soffit and
or turns and offsets to fit your fire- 57" minimum to unventilated sof-
place into locations such as base- Required pipe overlap: 11/4" fit when using a TB2.
ments or along interior walls. Use • Effect of additional 90° elbows: _
only the vent pipe recommended in reduces maximum horizontal
the installation instructions. distance by 3'
A special low clearance vent kit • From base of the unit, 711/4"
(TB2) allows you to construct the minimum clearance to ventilated
framing of an Inoperable window as
low as 9" from the top of the unit.
Figure 6 demonstrates the mini-
mum venting dimensions for a
standard horizontal installation or
the low clearance vent kit (T132).
Plan your installation carefully to
make certain it will comply with the
instructions. Here are some basic
considerations to remE�mber:
• 3" clearance required above vent
during a standard horizontal
installation; 2" clearance
required when using a TB2.
• 1" clearance required on bot-
tom and sides of vent.
• 1" clearance around the vent
required on vertical installations.
• Maximum horizontal run in hori-
zontal termination: 26'
• Maximum vertical run in hori-
I'�
zonta termination. ,_5
Figure 6
Soffit
~
26' Max. --I711/4"
16"
j
Min.
Venting can - from
I' terminate ventilated
25' Max.
within this soffit;
651/4" Min.
area. from
unventilated
12"
2' Min.
r soffit
501/4"
Min, to
top of
exterior
hole
�— 163/4" Min.,
3' Max.
Standard horizontal installation
Soffit
63/4'
---- 44" to 63" Min. from
top of ventilated soffit;
exterior 57" Min. from
hole unventilated soffit
141 /4~
217/8" Max.
Horizontal termination using TB2
The GC361 and GC421 up -vent
models require a simple, 5" B -vent
for operation. This vent must be
terminated above the roof line.
Check local building codes for
venting requirements in your area.
For proper operation, the venting
termination must be a minimum of
9' above the top of the appliance.
Horizontal offsets are possible, but
they must be no greater than 50%
of the vent height above the unit.
You should always try to minimize
horizontal distances to avoid overly
restrictive venting.
We recommend a vertical rise of 2'
be established prior to installing a
900 elbow on top of the unit. The
installation instructions have com-
plete guidelines for installation.
Note: We strongly discourage
against any 13 -vent fireplace being
installed in a basement or an area
susceptible to negative air pres-
sure situations such as in a living
room with cathedral ceilings.
GC300, GC361, GC400, GC421
Oirect Dent and. Up -vent Gas Fireplace Series
r
Ivailab% as:
•` a d rect venting system
• an up -venting system
heab'olator,