Loading...
HomeMy WebLinkAboutpitkin.eh.264505404003 (2014) BarnPitkin County Environmental Health Department Onsite Wastewater Treatment System (OWTS) USE PERMIT Permit for Continued Use of an Existing OWTS 76 Service Center Road, Aspen, CO 81611 Phone: 970-920-5070 Fax: 970-920-5077 www.aspenpitkin.com/EHNR Parcel ID #: 2645-054-04-003 OWTS Use Permit #: 0024.2014.powu (2) Date Issued: 06/25/2014 Issued By: Kurt Dahl Expiration Date: 12/25/2015 Owner(s): I Susan H Schumann Family Trust Property Address: 730 Rose Spur Rd Legal Description: Lot 3 Licensed Inspector: Carla Ostberg Inspection Date(s): May 29, 2014 5 � 5 • t Pitkin County Environmental Health Department Onsite Wastewater Treatment System (OWTS) USE PERMIT Permit for Continued Use of an Existing OWTS 76 Service Center Road, Aspen, CO 81611 Phone: 970-920-5070 Fax: 970-920-5077 www.aspenpitkin.com/EHNR Parcel ID #: 2645-054-04-003 OWTS Use Permit #: 0024.2014.powu (2) Date Issued: 06/25/2014 Issued By: Kurt Dahl Expiration Date: 12/25/2015 Owner(s): I Susan H Schumann Family Trust Property Address: 730 Rose Spur Rd Legal Description: Lot 3 Licensed Inspector: Carla Ostberg Inspection Date(s): May 29, 2014 SYSTEM INFORMATION Components Type Capacity/Size Primary Treatment Unit Concrete two-compartment tank 1000 gallons Secondary Treatment Unit N/A N/A Absorption Area Unknown Unknown Other System Components N/A N/A OWTS Use Status: ❑ In use at the time of the inspection. ®Not in use at the time of the inspection.* *If the OWTS was not in use at the time of the inspection, it is recommended that the system be re-evaluated when it is in use for a more accurate evaluation of the system. System Records: Permit #: N/A Date of Issuance: N/A Date of Final Approval: N/A # of Bedrooms or fixtures served by OWTS: System records were not on file, system serves a toilet and mop sink in the barn. Operational Status: After repairs to the risers and inlet tee the system is functioning correctly. The approximate field area did not show any signs of failure. This permit has been extended 6 months past the usual 1 year expiration due to the property not being occupied since the inspection. Inspector Recommendations: N/A Department Recommendations: Add an effluent filter to the outlet side of the tank to prevent solids from entering the field area. Issuance of this OWTS Use Permit is based solely on the conditions observed and reported by the inspector to the Department on the date of the inspection(s) and on Department records at the time of permitting. The issuance of this permit does not constitute a guarantee, warranty, or representation by the Department that the system will operate properly or will not fail or that the system will not be subject to future enforcement action to correct non-compliant conditions. Estimated capacity of the system has been listed on the permit and we recommend that you monitor and/or meter water use to prevent overuse and possible failure. 6ozq , 2o(q , poiv LL P,21)P—N June 13, 2014 Peter Obuhanick Obuhanick Construction, Inc. obuhanickconstruction(cD-yahoo. com Onsite Wastewater Treatment System (OWTS) Use Permit Inspection 730 #3 Rose Spur Road (barn) Lot 3, JH McCabe Subdivision Pitkin County, Colorado Mr. Obuhanick, As requested, CBO Inc. performed an Onsite Wastewater Treatment System (OWTS) Use Permit inspection at 730 #3 Rose Spur Road, Snowmass, Colorado on May 29 and June 9, 2014. This system serves the barn. No permit and record drawing was provided by Pitkin County Environmental Health Department (Parcel ID #2645-05404-003). The subject OWTS consists of one 1000 -gallon, two-compartment concrete septic tank followed and an absorption area of unknown size. There was evidence of root intrusion in the septic tank, so pumping was necessary in order to conduct a thorough inspection. The septic tank was pumped by B&R Septic on June 9, 2014 and a root mat that had formed around the outlet tee was removed. The septic tank appeared to have good integrity. Both inlet and outlet tees were present; however, the inlet tee was not properly installed. This was repaired after the inspection (seep photos below). The outlet tee was angled sharply downward which may indicate settling. The exact location of the absorption area is not known, but there were no signs of saturation, and no indication of failure at the time of the inspection. This evaluation is not a guarantee of future system performance. This inspection is good for one year. This report should be submitted to the Pitkin County Environmental Health Department. The following links are the required application and application checklist. Application: http://www aspenpitkin com/Portals/O/docs/county/Com%20Dev/EHNR/OWTS%20Use%20Permit% 20Application.pdf Application Checklist: http://www aspenpitkin com/Portals/O/docs/county/Com%20Dev/EHNR/OWTS%20Use%20Perimt% 20Application%20Checklist. pdf CBO Inc. 33 Four Wheel Drive Road Carbondale, CO 81623 cell) 970-309-5259 office) 970-704-0484 car1a.ostberg(d_)gmai1.com s June 13, 2014 Peter Obuhanick Obuhanick Construction, Inc. obuhanickconstruction(cD-yahoo. com Onsite Wastewater Treatment System (OWTS) Use Permit Inspection 730 #3 Rose Spur Road (barn) Lot 3, JH McCabe Subdivision Pitkin County, Colorado Mr. Obuhanick, As requested, CBO Inc. performed an Onsite Wastewater Treatment System (OWTS) Use Permit inspection at 730 #3 Rose Spur Road, Snowmass, Colorado on May 29 and June 9, 2014. This system serves the barn. No permit and record drawing was provided by Pitkin County Environmental Health Department (Parcel ID #2645-05404-003). The subject OWTS consists of one 1000 -gallon, two-compartment concrete septic tank followed and an absorption area of unknown size. There was evidence of root intrusion in the septic tank, so pumping was necessary in order to conduct a thorough inspection. The septic tank was pumped by B&R Septic on June 9, 2014 and a root mat that had formed around the outlet tee was removed. The septic tank appeared to have good integrity. Both inlet and outlet tees were present; however, the inlet tee was not properly installed. This was repaired after the inspection (seep photos below). The outlet tee was angled sharply downward which may indicate settling. The exact location of the absorption area is not known, but there were no signs of saturation, and no indication of failure at the time of the inspection. This evaluation is not a guarantee of future system performance. This inspection is good for one year. This report should be submitted to the Pitkin County Environmental Health Department. The following links are the required application and application checklist. Application: http://www aspenpitkin com/Portals/O/docs/county/Com%20Dev/EHNR/OWTS%20Use%20Permit% 20Application.pdf Application Checklist: http://www aspenpitkin com/Portals/O/docs/county/Com%20Dev/EHNR/OWTS%20Use%20Perimt% 20Application%20Checklist. pdf Please call with questions. Sincerely, (,�th La Dates Carla Ostberg, MPH, REHS NAWT Certified Inspector Certification # 11 0441T Exp. 2016 I G Outlet tee with root and dirt mass Clean out Lids for inlet and outlet sides of the septic tank f septic tank lids and clean out next to bam Y ,4: Root mass removed from septic tank Inlet tee installed improperly. Opening was capped so effluent will be diverted down into tank. Top of tee is not open. This should not cause a problem with the functioning of the system. Repair 6/13/14 6 -inch riser installed on inlet side of septic tanK Clean out between septic tank and absorption area View, looking west toward barn Pipes with no caps — not known how/if they connect to the uW I b Pipes capped 6/13/14 E'er f KIN Onsite Wastewater Treatment Systems (OWTS) Use 1 Permit Inspection Form L. OU N T� Pitkin County Environmental Health Department 76 Service Center Rd, Aspen, CO 81611 t� + Phone: 970-920-5070 Fax: 970-920-5374 Website: www.aspenpitkin.com/ehnr Inspection form for continued use of an existing OWTS Owner's Name: Address: Parcel Number: Inspection Date: Inspector's Name: Business Name: Phone Number Email: 5-0 Pitkin County Systems Inspector License numoer: 4-,P x A copy of this inspection renart will be remitted to Pitkin County Environmental Health Department by the licensed Systems Inspector within 60 days of the inspection regardless of whether the system passes or fails. QUESTIONS FOR PROPERTY OWNER PRIOR TO INSPECTION Is the home currently occupied? YES NO If NO, how long has the home been vacant? How many bedrooms are in the home? k Lt {' >Mo %Sir.. i If secondary treatment is used, who is the maintenance provider? N RECORDS: Were system records available from Pitkin County? YES — Na`� If YES: Permit number: Date of Final Approval: # of bedrooms permitted: Was an as -built drawing available? YES NO Is the as -built drawing accurate? YES NO If NO: Complete a drawing of the system on last page of this form as accurately as possible. Any question marked FAIL will require correction before an OWTS Use permit is issued. SITE CONDITIONS: Proper grading, no evidence of erosion? t PASS l FAIL Improper vegetative cover? YES Evidence of compaction such as heavy machinery or livestock? O YES Improper discharges such as straight pipes? FAIL Evidence of high ground water? `- NCO'' . YES Snow cover present? Nv j YES Page 1 6 r� 0% C� j ., tib, PUMPS/DOSING SIPHONS: Tank 1 Tank 2 _NO Tank 3 PASS FAIL TANK: 0 gallons PASS FAIL gallons NO UNKNOWN gallons Tank capacity If YES, does the unit appear to be in good working condition? YES NO Does the owner have a current maintenance contract for the unit? YES NO UNKNOWN Maintenance Provider: Phone: Tank material i. must be submitted to Pitkin County Environmental Health Department. copy of the contract Distribution Box or ADV part of original design? YES NO # of compartments YES NO Is it level and in good condition? PASS FAIL Date of last pumping i' i Lids/risers in good condition P FAIL PASS FAIL PASS FAIL Risers to grade YES NO) YES NO YES NO Riser height Z� Riser condition/watertightness ' Inlet sanitaryT/baffle PASS LAIC PASS FAIL PASS FAIL Outlet sanitary T/baffle !ASS`., FAIL PASS FAIL PASS FAIL Effluent filter (if part of design) PASS FAIL ,; N/A PASS FAIL N/A PASS FAIL N/A Condition of tank material ^ PASSE FAIL PASS FAIL PASS FAIL Tank was pumped for inspection YESNO YES NO YES NO If YES, list the pumping company If NO, when was the last pumping Scum level (1st compartment) inches inches inches Sludge level (1st compartment) inches inches inches Scum level (2nd compartment) inches inches inches Sludge level (2nd compartment) inches inches inches Backflow (if pumped) PASS FAIL PASS FAIL PASS FAIL Midtank baffle PASS FAIL N/A PASS FAIL N/A PASS FAIL N/A Watertightness PASS FAIL J PASS FAIL PASS FAIL PUMPS/DOSING SIPHONS: YES is a pump or dosing siphon present? _NO If YES, is the pump/dosing siphon functioning properly? PASS FAIL Does the pump/wiring/dosing siphon appear to be in good condition? PASS FAIL Is the high water alarm working, both visible and audible? PASS FAIL SECONDARY TREATMENT: YES NO UNKNOWN Is a secondary treatment unit present? If YES, does the unit appear to be in good working condition? YES NO Does the owner have a current maintenance contract for the unit? YES NO UNKNOWN Maintenance Provider: Phone: YES If there is no maintenance contract, a contract must be in place prior to occupancy of the home. A must be submitted to Pitkin County Environmental Health Department. copy of the contract Distribution Box or ADV part of original design? ABSORBTION AREA: FAIL Effluent surfacing? Evidence of past surfacing? { NOj YES Surface dampness? N YES Excessive odors? YES Probing Field location verified by observation ports or probing: orts Liquid in observation port? YES If YES, record depth: inches Distribution Box or ADV part of original design? YES NO If YES, is it accessible from grade? YES NO Is it level and in good condition? PASS FAIL Page 2 UNKNOW Any problems with the system that were not addressed in the inspection checklist? Please list any recommendations for the continued use of the system: Were any repairs done as a result of this inspection? NO YES 14: vcc . 1-- rincrriho tho rPnairs_ To the best of my knowledge, and training, the information collected in tnis inspection is accuraie as u1 jlx i _�— 20 1' i 1 ^ �~-� Licensed Systems Inspector Signature: ( A .l (.f V Additional Notes: RAW, 0 � Baa • • Clearly label any pictures and attach them to this form_ Page 3 IV abed GX -a:)uaja}aj ainin} ao} sluauodwoa waasAs aq44o uo'4elo) aq} ajeln2ueu} o; pasn aq uea sluawainseaw i:)exa'asnoq aql;o slauaoa se vans s.ialiew suis A:padoid ayl uo 119nn Aue;o uo4eaol ay; pue sjuauodwoa wa:sAs pe juawnaop 04 ains ag -algissod se Alaleinaae se walsAs ayi weigeip asea{d `aleinaaew sem ll!nq-se aqj jo walsAs sign SOI lsixa sBuinneip lynq-se ou 11