HomeMy WebLinkAboutpitkin.eh.264511100002 (2013) CDU�1Txi COUNT Oti_,ITE WASTEWATER TREATMEk. SYSTEM (OWTS) CONSTRUCTION PERMIT 76 Service Center Rd- Aspen, CO - 81611 Phone: 970.920.5070 Fax: 970.920.5374 Permit #: 0005.2013.pow2 Parcel ID #: 2645-111-00-002 Permit Issued: ®NEW CDU ❑REPAIR ❑REMODEL/ADDITION ❑TANK ONLY ❑FIELD ONLY ❑AMENDMENT Owner(s): Charlie Mountain LLC Property Address: Legal Description: Size of Lot: 33.54 Size of Buildinq: 4100 Snowmass Creek Rd 1000 ft2 Acres Sq. Ft Detached Accessory Unit Size of Accessory Unit: The systems are designed for: The 1 bedroom CDU. Designed By: Phone #: Fax #: ❑YES []NO Sq. Ft. All Service Septic Project #: 1948 Dated: October 8, 2012 970-618-5033 Mailing Address: PO Box 2844 Glenwood Springs, CO 81602 303-216-2796 Email Address: cbo261 O@yahoo.com Perc Rate: 30 mpi Minimum Tank Capacity: Profile Hole Depth: 281 Gallons 8 ft Depth to Groundwater or Bedrock: 7 feet Minimum Absorption Area: 311 ft2 (30% Reduction) Permit Conditions: This OWTS Construction Permit is approved on the condition of compliance with the engineer design as submitted with the application and the specifications cited above. Changes must be approved by this Department and the engineer prior to construction. This is an amendment to the previous permit # 0030.2012.powt. Permit # 0030.2012.powt is void. The system is designed to treat sewage in a 1000 gallon 2 -compartment septic tank with an Orenco pump and Biotube pump vault in the second compartment. The effluent will be pumped to a gravelless chamber bed of either (2) 2 rows of 8 quick -4 chambers or (1) 3 rows of 9 ARC -36 chambers. Due to groundwater at 7 feet, the soil treatment area shall be no deeper than 2 feet below grade and at least 1 foot of cover shall be place over the chambers. The soil treatment area shall be a minimum of 100 feet to any well and 50 feet to any stream or irrigation ditch. This Permit must be kept on-site during installation. The engineer must do a final inspection of the installation and submit an "as -built" letter to this Department within 30 days of the final inspection, unless a longer period of time has been agreed upon, in writing. This Department must also be called for the final inspection with a minimum of 48 hours notice. Minimum horizontal distances between components of the system and physical features shall conform to the requirements of the Pitkin County OWTS Regulation. This Permit is conditioned upon the property owner(s) providing for regular inspection, cleaning, and maintenance of the system by qualified personnel, in accordance with the manufacturer's recommendations and the requirements of the Pitkin County OWTS Regulation. Issuance of this OWTS Construction Permit does not constitute a guarantee, warranty, or representation by the Department that the system will operate properly or will not fail. Issuance of this permit does not imply compliance with Pitkin County building and/or land use regulations, nor guarantee issuance of building and/or land use permits. THIS PERMIT IS EXPRESSLY CONDITIONED UPON COMPLIANCE WITH ALL REQUIREMENTS OF THE PITKIN COUNTY OWTS REGULATION, INCLUDING BUT NOT LIMITED TO THOSE CONDITIONS SPECIFIED ABOVE. Plans and specifications for the proposed OWTS have been reviewed and are considered satlstactory. rermisslon is rieieuy given to the property owner(s) to perform the work indicated in accordance with the Pitkin County OWTS Regulation. This Permit will expire 1 year from the date of issuance unless construction on the system has commenced. An "as -built" drawing must be submitted and approved by EH before final approval of the system will be issued. Issued By: Date: 08/02/13 Expires: 08/02/14 Installer: "' License #: Reactivation Authorized by: Final Approval Issued By: Date: New Expiration Date: FeepaM � � 1TKIN COUNT Permit #: 0030.2012.powt OI.sITE WASTEWATER TREATMEw T SYSTEM (OWTS) CONSTRUCTION PERMIT 76 Service Center Rd- Aspen, CO - 81611 Phone: 970.920.5070 Fax: 970.920.5374 Parcel ID #: 2645-111-00-002 Permit Issued: ®NEW CDU ❑REPAIR ❑REMODEL/ADDITION ❑TANK ONLY []FIELD ONLY ❑AMENDMENT Owner(s): Charlie Mountain LLC Property Address: Legal Description: Size of Lot: 33.54 4100 Snowmass Creek Rd Size of Building: 1000 ft, Acres Detached Accessory Unit: ❑YES [:]NO Sq. Ft. Size of Accessory Unit: _ The systems are designed for The 1 bedroom CDU. Designed By Phone #: Fax #: All Service Septic Project #: _ 970-618-5033 Mailing Address: 303-216-2796 Email Address: Perc Rate: 30 mpi Profile Hole Depth Minimum Tank Capacity: 281 Gallons Sq. Ft. 1948 Dated: October 8, 2012 PO Box 2844 Glenwood Springs, CO 81602 cbo2610@yahoo.com 8 f Depth-toQroLndwater or Bedrock: ➢ 8 f Minimum Absorption ;ea: 311 ft2 (30% Reduction Permit Conditions: This OWTS Construction Permit is approved on the condition of compliance with the engineer design !(submitted with the application and the specifications cited above. Changes must be approved by this Department and the engineer prior to constri tion. stem is designed to treat sewage in a 1000 'a on 2 -compartment septi tank. The tank will have an effluent filter and The system g g will distribute effluent to a gravelless chamber be leac1e�ld of either (2) 2 rows of 8 quick -4 chambers or (1) 3 rows of 9 ARC - 36 chambers. The leachfield shall be a minimu of 100 felt to any well and 50 feet to any stream or irrigation ditch. This Permit must be kept on-site during installati . The engineer must do a final insp on of the installation and submit an "as -built" letter to this Department within 30 days of the final inspectio , unless a longer period of time has be agreed upon, in writing. This Department must also be called for the final inspection with a minimum of 48 hours tic'. Minimum horizontal distances between componen s of the system and physical features shall conform to the requirements of the Pitkin County OWTS Regulation. This Permit is conditioned upon the property owner(s roviding for r gular inspection, cleaning, and maintenance of the system by qualified personnel, in accordance with the manufacturer's recommendations nd the requi ments of the Pitkin County OWTS Regulation. Issuance of this OWTS Construction Permit does not constitute a guarantee, warranty, or reprr entation y the Department that the system will operate properly or will not fail. Issuance of this permit does not imply compliance with Pitkin C�my buildin�2jj nd/ land use regulations, nor guarantee issuance of building and/or land use permits. THIS PERMIT IS EXPRESSLY COIF ITIONED UPON COMPLIANCE WITH ALL REQUIREMENTS OF THE PITKIN COUNTY OWTS REGULATION, INKUDING BUT NOT LIMITED TO THOSE CONDITIONS SPECIFIED ABOVE. Plans and specifications for the proposed OWTSSIZave been reviewed and are considered satisfactory. Permission is hereby given to the property owner(s) to-per'fo e work in icated in accordance with the Pitkin County OWTS Regulation. This Permit will expire 1 year from the date of issua s construction on the system has commenced. An "as -built" drawing must be submitted and approved by EH before final approval of the system will be issued. Issued By: X , ``- > Date: 1211/12 Expires: 12/11/13 Installer: License #: Reactivation Authorized by: Final Approval Issued By: Date: New Expiration Date: F] Fice paid {� ONSITE WASTEWATER TREATMENT SYSTEM (OWTS) CONSTRUCTION PERMIT APPLICATION rlfnvR 76 Service Center Rd •Aspen, CO - 81611 Phone- 970.920 Fi070 Fax- 970 920.5374 Parcel ID# (available from the Pitkin County Assessor's Office _ 970-920-5160 or at �ti^rn'+.pilkin3sscsso;y ;): I LP 4 J130 0 0 2 - Purpose of Permit: NEy" ❑REPAIR DUE TO FAILURE ❑REMODEL/ADDITION ❑TANK ONLY ❑FIELD ONLY Cost of System Repair or Remodel/Additr :)n (approximate): Property Address O Oo trv�0.�S Lot: Block: Fling: Subdivision Property Owner(s)- �Email Address: np-r li 9-� u.� i r1 ULC- Owner's Mailing Address: City, State, Zip: Home Phone: Business Phone: •r'.nntact information must be provided to - the owner signing this application. Building Permit # (if applicable): �i Lot Size (in acres)' 33.51 t Size of Building (square feet): r Number of Potential Bedrooms: Detached Accessory Unit? El YI :S ELy NeN O Size of Accessory Unit (square feet)' Number of Potential Bedrooms In or Fixh re List for the Accessory Unit Water Source: [21PRIVATE WELL ❑ SURFACE WATER ❑ SPRING ❑ COMMUNITY/PUBLIC WATER SYSTEM Name of Community/Public Water Systen (rt applicable)- Engineeringirtn Job Number: Phone Number: 10, Fax Number I' - Mailing Add s City, State, Zip: Pos" Zgy S r' n PLEASE READ BEFORE SIGNING: certify that the above Information is c omplete and accurate and that 1 have provided complete and accurate information in all of the documents included in my application package. I acknowledge that EH/NR may revoke any permit I am issued if my application is found to contain any inaccurate, false, or misleading information. I understand that no construction maybe undertaken on an OWTS until an OWTS Construction Permit is issued. Owner Signature (Required) AS A77-j4/A✓- Date. `�, 3 p, 2-0 1 2.., ow��G,'n f LLC Applicant Signature: -O1T Date. � r t ► IZ FOR OFFICE USE ONLY Received by EN/I IR Staff. Fee & Receipt #: Date: I t n��� 1 33 3 6 1z l s � z ........�:... �.�. � ,ruic uc�u acre ne.rn_fii��nrmc� Si.nr niG�t Fo��W7�ccnstr cr -: aputr�auon.xlm ilpu.u...i. iU, „�., Chu PITKIN COUNTY ENVIRONMENTAL HEALTH DEPARTMENT Percolation Test and Soils Data Form - TABLE 1 - PROJECT 1948 4100 Snowmass UreeK Hoaa PROFILE PIT #1 Date of Test: 3-14-12 0 - 1' Topsoil, Root Zone, Sandy, Gravelly 1'- 8' Sand, Clayey, Gravelly with Cobble and Boulders. Difficult Excavation, Very Dense, Moist, Red/Brown/Tan No Groundwater or Bedrock was Encountered PVC Installed Hole Hole Interval Measurement at Measurement at Change (in.) Percolation Rate No. Depth (in.) (min.) Start of Interval End of Interval (min./in.) MPI (in.) (in.) 1 29 20 10.25 11.75 1.50 20 11.75 13.50 1.75 20 13.50 14.50 1.00 20 14.50 15.75 1.25 20 15.75 16.75 1.00 20 16.75 17.75 1.00 20 2 31 20 4.00 6.00 2.00 20 6.00 7.75 1.75 20 7.75 9.00 1.25 20 9.00 10.50 1.50 20 10.50 12.00 1.50 20 12.00 13.50 1.50 14 3 32 20 19.25 21.00 1.75 20 21.00 22.50 1.50 20 22.50 24.00 1.50 fill 20 12.75 13.50 0.75 20 13.50 14.00 0.50 20 14.00 14.50 0.50 40 PO Box 2844 Glenwood Springs, CO 81602 Ph 970618-5033 Fax 303-216.2796 October 8, 2012 Glenn Horn CIO Charlie Mountain LLC 215 South Monarch Street, Suite 104 Aspen, CO 81611 Project No. 1948 Subsurface Investigation and Onsite Wastewater Treatment System (OWTS) Design CDU and Free Market SF House - Parcel A 4100 Snowmass Creek Road Pitkin County, Colorado Glenn, ALL SERVICE septic, LLC performed a subsurface investigation and an onsite wastewater treatment system (OWTS) design for the subject property. A caretaker dwelling unit (CDU) and Free Market Single Family (SF) House are proposed. The property is located outside of Aspen, in an area where OWTS and wells are necessary. SITE CONDITIONS The property is currently developed; however, the existing structures on the property will be demolished prior to construction of the new residences. Water to residences will be provided by a private well. SUBSURFACE CDU: The subsurface was investigated by digging three profile pits and two sets of three percolation holes, as indicated. Profile #1 and the associated percolation holes are closest to the proposed absorption area that will serve the CDU. The materials encountered in the profile pit #1 consisted of 1.0 -foot of a sandy, gravelly root zone, underlain by sandy, clayey, gravelly, very dense, moist red/brown/tan soil to the maximum depth explored of 8 feet. No groundwater or bedrock was encountered, but excavation was difficult. A gradation was performed on profile pit #2 resulting in 14% gravel, 51% sand, and 35% fines. See Tables 1, 2, and gradation analysis for details. Free Market SF House — Parcel A: The subsurface was investigated by digging three profile pits and two sets of three percolation holes, as indicated. Profile #3 and the associated percolation holes are closest to the proposed absorption area that will serve the 2 -bedroom Free Market SF house on Parcel A and the Free Market SF house on Parcel B. The materials encountered in profile pit #3 consisted of C Page 2 1.0 -foot of sand with cobbles and gravel, underlain by sand, clayey, gravelly, very dense, moist red/brown/tan soil to the maximum depth explored of 8 feet. No groundwater or bedrock was encountered, but excavation was difficult. An average of 30 MPI percolation rate will be used to design the OWTS. See Tables 1, 2, soil log, and gradation analysis for details. DESIGN SPECIFICATIONS CDU: The OWTS serving the CDU will be designed to serve 1 -bedroom. An average daily wastewater flow of 150 GPD will be used. The installation must include a 1000 -gallon, two-compartment septic tank with an effluent filter. Effluent will be gravity fed to two gravelless chamber beds consisting of 2 rows of 8 Quick 4 chambers, for a total of 32 chambers, or one graveness chamber bed consisting of 3 rows of 9 ARC 36 chambers for a total of 27 chambers. Free Market SF House — Parcel A: A 1000 -gallon, two-compartment septic tank with a Biotube pump vault will serve the Free Market SF House on Parcel A. A P-30 pump and standard control panel are recommended. The absorption area will be sized to accommodate flow from both the Free Market SF House on Parcel B (5 bedrooms with living area greater than 6000 square feet) and the Free Market SF House on Parcel A (2 bedrooms). An average daily wastewater flow of 1300 GPD will be used to size the absorption area which will consist of a level 6" deep sand bed, 33 -feet wide by 54 -feet long. 72 Eljen modules will be placed on the bed, 6 rows of 12 modules, with 3 -feet of space between each row. Depth of cover over modules should be between 12" and 24". Construction must be according to Pitkin County OWTS Regulations, the OWTS Construction Permit provided by Pitkin County Environmental Health Department, and this design. OPERATION INFORMATION AND MAINTENANCE The surface of the drain field should be seeded upon completion. Vegetation is an important factor in drain field performance. Erosion control should be practiced prior to and during re -vegetation. No heavy equipment, machinery, or materials should be placed on backfilled drain field. Livestock should not graze on the drain field. Plumbing fixtures should be checked to ensure that no additional water is being discharged to OWTS. For example, a running toilet or leaky faucet can discharge hundreds of gallons of water a day and harm a drain field. The homeowner should pump the septic tank every two years, or as needed gauged by measurement of solids in the tank. The effluent filter should be cleaned annually, or as needed. Garbage disposal use should be minimized, and non -biodegradable materials should not be placed into the OWTS. Grease should not be placed in household drains. Loading from a water softener should not be discharged into the OWTS. No hazardous wastes should be directed into the OWTS. Mechanical room drains should not discharge into the OWTS. The OWTS is engineered for domestic waste only. ADDITIONAL CONSTRUCTION NOTES If design includes a pump, air release valves and weep holes should be installed to allow pump lines to drain to minimize risk of freezing. Excavation equipment must not drive in excavation of drain Page 3 Id due to the potential to compact soil. Extensions should be placed on all septic tank components allow access to them from existing grade. Precast concrete tanks and distribution boxes should be -d, unless plastic or fiberglass is required. Access to all tank compartments and distribution devices optimal. INSTALLATION OBSERVATIONS ALL SERVICE septic, LLC must view the OWTS during construction. The OWTS observation should be performed before backfill, after placement of OWTS components. Septic tanks, distribution devices, pumps, dosing siphons, and other plumbing, as applicable, must also be observed. ALL SERVICE septic, LLC should be notified 48 hours in advance to observe the installation. LIMITS: The design is based on information submitted. If soil conditions encountered are different from conditions described in report, ALL SERVICE septic, LLC should be notified. All OWTS construction must be according to the county regulations. Requirements not specified in this report must follow applicable county regulations. The installer should have documented and demonstrated knowledge of the requirements and regulations of the county in which they are working. Please call with questions. Sincerely, ALL SERVICE septic, LLC Reviewed 1 VVVV Richard H Carla Ostberg, MPH, REHS 3 copies r 0 U� r, co 10 ^ N C14 (D T O N m p ) M (DO omC �X IL0CLL1u C= cr= Nm 1 o ' z Z_ o / / / /� 1 / // /� O m m CD �T o� Mn Mn/ � 0 w \ / mW;�� W� ° / / \ W° X00 CL Q14- cwo Wm CZIN C) oz \ I �\ \ :3� ` o a- 00 o o \ (Z° -Nd I �-ja zo o // / ` 1 0=° \ / 1 \ J J \ LL UO af / 1 Z / m f / 6U� / OU /�UW) L L i / aWW w / ( I S 02` / � U U - C8, —UW / (/ 00 U� l �, 1- �,UD O O 0) ca O L N 111 X aL 0- LL C� O 0 LO f w J to � a W F- � m t Cl) N OUzmO F-oa g UWpL)LL} �ZZ Z00 Z W 0{-N0a �wZpZ�0F-F}- r O U O omL)ZmOW<� ao Z mQ U p J p O Z Z a T a pcnp-JO>ww - 0>LLZ0C)a m J 0 rnm > = m0-OS?SZF-J cn )00 Q �Z 0CQUla- =a02N m2F-0 JO��zZ CF- 0�Z�O►-OJU w_WWamW(tw> p�0�~Wi=w wO<mzw� F-(!) LL w U)<Zw-W F-J5T- Q O O W m W Q o a cn O� ~wwW Jit -LL F•W}g pZ WOMp>ZZw2U W F- 0 w X W 13�Ow2F-J UX =ZWa0UF=-Ii00 Q W l a Z W J W N O 2 F- Nwzw<F-Z W 3:m wLL m o }¢ Z W O W F W o o z w 0 to a> F-wDzoo<w)-W < J ppd UJJF-U Fw- 02 O WW F FS-WOUaNC90Op� —az �WZOw z mw J3:mw—owYeo n p O 0U Q X i7 JQ�a� J Z LL O—vi ~2 W U)Qg0Y V � ~co W (f)U) < ~Z m 1152 Jmm O>O:D W & a1 -000 ZC3c) wJU2ZF. Y CQ� z z LLpUa O p (� m oe- N — X 0 m I—I (V W �aWa�W J U U Z O � O m 1=III= III-, a W�WQcrX N � c c E Qa -C F'�� �� LL a o a I_ 1—IIi. 1=1 m wwWYoW pmwF-F- 0° � F-- >� w" = m � Q_z —III—_ - III— >- cn 2 9! g c oz o U U) v� ��_ w w o Q v rY J O Of �Z�U=pw- v O c 0) U) Oa ?OU cJ Q Ir a p--ZF-0 Jn 0 Y O - L- a LLO Q (Ui) m m U) Cl) d - C) d W LL v o COm tU O m J) . L Z O cu � O W U N N O w F- 11=1 11=1 11=1 I �I I G z III -III -I I u �_ > F_ m> O a IIF-It'Iil z Z W m aF-U M}~ tL0 Fa Na afW� io v Z> W 9 MU OU)a HU J z - Eo M �rOa ww Q a p wZ J Q W m o v LU w >- w LL- ~ a) z F- Q Ix U = r iV T '0 N o et W Y J ao U N 60 W U-) v > p m LL®LL U 4' O W o co c Z H ¢ aOC)N do U)O co U J m o 0 o) Z F - w W 0- Z W p J J Zm — c M O m 0 m J U) a W O i v c � a LL wJ� JQ � Z LL <D T �� o �- .o N 0 U O m Q T = N m O 2' 3 O ami 99) @ N O LL U 2 O O LL Of LL `) (fl m W U') CI) rn 1 O O 0 H Z g2 Ix (n U 0 w 0 z z �W W O m W ❑ F- m O W O W w w W x co F- O_ F- W 2 C7 ZY also T- )Htwi O Z -jQ 0 W N CD 0 Z� o< af a BOO ? ;� ❑ O Cbz W �o(n(n~ ❑ W W(n11 W O U WOZ Z 0U) W W Q W ❑ m W Q O M W N J Cz9 mZ a0 OW to❑XW Q NmZ y(o d� O 00 �Q Q L �OIOn N� ° m Q wmmN w OZOJa� O u 11 Q LL- ❑F w W OQN W11 Q WZU)U=t2zQCI) W LLOQ�o LL2EL ww 0� 2 - ❑ (n(,� II �0- �'—�N�Q W = x Q 0) of 11 to y�a WJ 00 �NT� W00 �� a<U)� Y= UF- d W 00.- �� Q W r- C) ori +,O U W LOQ W MU' U � W _ L`W 00 �" O Z �M M II F- L Z a r�- Z �Z W Z UF-ODw W(Lm II W ZU II - II x U _ 11 O_ C9 n W Li. M WN II O o0m N W II LL W YN II xC3 YO F- 11 r(nJF- (n C7 0 x In PO `�F-g❑J� a m oo U) � x tO a X1=0 F"zZ❑ 0'W�LL�W t� Z W} O� W� W�=� w� w 0= 11 O 2 Q 0 u 3: 2 w F- W g 0 X 0 W O O M X0 -0 00 w �OwC1 wz wF �U�ww=cnUF- = woLL Wwz w v0i~❑=LL ¢O�lili0 �[ �0- N-� m OmmU❑zz LL wz�dLL W�0 a' mwza} �gCOU)"T� V N 0-) -j W W Z>" II �O Z W 22Z WE (n M II m J Q QUO J x0� Qi ❑ 0: (f (fJ QzQOa'QQWIII F- LLOmJ:Fc�z LL�J Z ❑�F-�Q ZC-4 11 N J i O af ��00 DQ O�WUwUU�LLO Y 2W007) �O� O W>-0W0--LLLL-Q LL J U C) OC7 F -F- O W J O F-�'❑ 11 W O W Oww� _ -1 DWW,LLF-00 < a_WLLW 20 F- CL C)Q xWWQO _ N -0 YQ �°J�OZ 0o aJ JWQ�QOcn2LL 2 W JC�z❑ a.C) ���❑WJ000W2F-Q� �_ cu C F-. a) O O❑ J F- = F- J J W GQ *z 1 xT ODUmQ❑OF-ZC9Q W W3��Q YW x`' O°'UZ�Q aU�F c7oo E Of WO W— Z� W (DIPJ. F -W F -❑_❑Z F- W CO LO W(nF- Zmp W (n 11 JUo F- Wofcr_ W cu OZ Q 00 LO QNW in 0mN>>_ WO w . TWO Q �(n m Q Wp0»W >> W— 4-j U Q❑ F- 04 Qa0�F-NM>(OJF- LL N�QOF- C4 IT QCiU(nNF Qa a(D>JLL(O 0 U U � C C ❑ �( OU) o C, as (D L cu > LLl F- U z = m o;(z z J CO w Q F - 0 w o>mn�(a 0 OQ (m�0wp¢ow IrZ IL a: (D F W cr a=mY ¢ W F- 0 Q�ccm Q 3 W z CE O Cl) 2 0 =°z>0z o 0 z z� Q F- F-Qcn20J— z O Ow Y �w-Iw mU> w -> JQQ 0>mcnc.Q Y w0Q 00m ZQmZ6LLO w 0 OF J Ow mw C7 <Croww_x O (r 0 U) 0 0 c[ O W F- W It O Jw O Q Q O 0 J d::0::0::0::0::0::0:.0::0::0:: � =mY m Q OH Q�CECE m lr 0Z Z } _2 Y d N Q IrQUaO O cD O>OZ z �MUZ z> �Quj20F]- o=aQ o z 70 OJ w --i ~O W W t6 0>mcn�UQ Qu'J `o O U LL 0Cm7 (�nCm7�000w 0 LL cr viof.0 CL (1) O co H 04 O U X o0N M Z ra °3 C) J W O t f4 000 ac7aLL =>LO 0 cis I I I I I I I I I I I I •a.:. L33d --d34 as OHO "' H1 -jr- 0) d C= r r-� ProPakTM Effluent Pumping System - 2nd Compartment Drawdown -1000-Gallon Scale: l".T IJ comrol Penes mp pvile. Ppw curs) Slmumpinq system �S'1 Boa Cab Grlps FGarplean Oeakered �W wltN NN $teel PVC RRpka QapM-PVC her wNN Orpmmellal Moy hom Riaar Irm T.--I Ta pOon4W aPmW TenN ndaPUr !Gael pr ad.) nnitlN hhx EYRUNnI gNcMaga O TANK DETAIL Nor TO scup 1000 -gallon, Single Compartment Septic Tank IW Oaa o R m afh I140 9 TANK DETAIL no ro scdrE FPW C.MI* w.r km P" Or— Eft- Pump Blot p' -p Veuk 1 IVNMarq *A — IDR E EM KIER TO ET 7E k with the Addition of an Effluent Filter -1000 Gallon, Top al W to com. I' ham top al tank lukt Tw-1 ORENCO BRAND NAME NOT ENFORCED n TANK DETAIL I� Hoi ro scue C,DtA nW ONNIdgN Xaola (fWd cul to Not) T.. M.pW (.0 or hallo) VNrd OHM. EMuapt Nckaaya WW." Ohah.r OHM.. Valk INat PMN Oartddaa it nllar AI P.O. Box 2844 Charlie Mountain, LLC. - Parcel A Revision: 10/8/12 11 ` Glenwood Springs, Colorado 81602 4104 Snowmass Creek Road W6' 0 Sfi ll� Phone 970 SfflYICf Fax 303.216.2796 Project Number: 1948 Drawn By: ANG sneer 6 or 7 ALL33 Four Wheel Drive Rd Carbondale, CO 81623 1 910-309.5259 11111 H s i September 6, 2014 Dennis Derham diderham(a)_gmail.com Onsite Wastewater Treatment System (OWTS) Installation Observations Charlie Mountain, LLC - Caretaker Dwelling Unit (CDU) 31 Charlie Way (formerly 4100 Snowmass Creek Road) Pitkin County, Colorado OWTS Construction Permit Number 0005.2013.powt2 Mr. Derham, Project No. 1948 ALL SERVICE septic, LLC observed the installation of the onsite wastewater treatment system (OWTS) on August 20, 2013 for the subject property. Aspen Earthmoving installed the system. The installation included a new 1000 -gallon, two-compartment Valley Precast concrete septic tank with a Biotube® Pump Vault and pump in the second compartment. The filter in this compartment must be cleaned annually, or as needed. The location of the tank was moved closer to field because of groundwater issues near the foundation of the CDU. Effluent is pumped to two gravelless chamber beds, each with two rows of 8 `Quick 4' chambers in each bed for a total of 316 square feet of infiltrative area. The field installation was shallow, no more than 2 - feet below native grade, to assure at least 4 -feet separation between the infiltrative area and seasonal high groundwater. The OWTS was generally installed according to specifications. This observation is not a guarantee of workmanship and/or parts and materials. ALL SERVICE septic, LLC should be notified if changes are made to the OWTS in the future. Any additional OWTS construction must be according to the county regulations. LIMITS: Observations are limited to components that are visible at the time of the inspection. The installer must have documented and demonstrated knowledge of the requirements and regulations of the county in which they are working. The quality of the installation is dependent of the expertise of the installer, soil type, and weather conditions. Please call with questions. Sincerely, ALL SERVICE septic, LLC CX,q Com- os-�s Carla Ostberg, MPH, REHS Reviewed A Richard H Air, .%Ib • imei iee Second compartment with Biotube® Pump Vault rows of 8 `Quick 4' chambers each row for a total of 32 chambers View of tank and field, looking east Gravel bedding under pipes for good support I ft Mi CJ PO Box 2844 11 Glenwood Spdngs, CO 81602 Ph 970.618.5033 Fax 303.216.2796 July 19, 2013 John Evans North Fork Builders j evans knorthforkbuilders.com Onsite Wastewater Treatment System (OWTS) Design Amendment OWTS Permit 0031.2012.powt (CDU) 4100 Snowmass Creek Road Pitkin County, Colorado John, dDo 4 , zo13 , ?OBJ Z Project No. 1948 ALL SERVICE septic, LLC was notified of groundwater in the foundation of the CDU. On July 18, 2013 a site visit was conducted and the pipe in Profile #1 was still present and no groundwater was observed. An additional profile hole was excavated and groundwater was present at approximately 7 - feet. An estimate of groundwater at 6 -feet will be used for this design. DESIGN SPECIFICATIONS CDU: The OWTS serving the CDU will be designed to serve 1 -bedroom. An average daily wastewater flow of 150 GPD will be used. The installation must include a 1000 -gallon, two-compartment septic tank with an Orenco® pump and Biotube® pump vault in the second compartment. A minimum 2" line must be run from the tank to the manifold. There must be a high point for adequate drain -back after each pump cycle and a weep hole in the line before it exits the tank. The pump line should be well bedded to avoid any settling. Effluent will be pumped to two gravelless chamber beds consisting of 2 rows of 8 Quick 4 chambers, for a total of 32 chambers, OR one gravelless chamber bed consisting of 3 rows of 9 ARC 36 chambers for a total of 27 chambers. Installation of the chambers may not be more than 2 -feet below grade and there must be at least 1 -foot of cover over the chambers. This letter and attached pump specification should be used in conjunction with the design letter and drawings dated October 8, 2012. This letter should be submitted to Pitkin County Environmental Health Department. Construction must be according to Pitkin County OWTS Regulations, the OWTS Construction Permit provided by Pitkin County Environmental Health Department, and this design. OPERATION INFORMATION AND MAINTENANCE The surface of the drain field should be seeded upon completion. Vegetation is an important factor in drain field performance. Erosion control should be practiced prior to and during re -vegetation. No heavy equipment, machinery, or materials should be placed on backfilled drain field. Livestock should not graze on the drain field. Plumbing fixtures should be checked to ensure that no additional C • Page 2 water is being discharged to OWTS. For example, a running toilet or leaky faucet can discharge hundreds of gallons of water a day and harm a drain field. The homeowner should pump the septic tank every two years, or as needed gauged by measurement of solids in the tank. The effluent filter should be cleaned annually, or as needed. Garbage disposal use should be minimized, and non -biodegradable materials should not be placed into the OWTS. Grease should not be placed in household drains. Loading from a water softener should not be discharged into the OWTS. No hazardous wastes should be directed into the OWTS. Mechanical room drains should not discharge into the OWTS. The OWTS is engineered for domestic waste only. ADDITIONAL CONSTRUCTION NOTES If design includes a pump, air release valves and weep holes should be installed to allow pump lines to drain to minimize risk of freezing. Excavation equipment must not drive in excavation of drain field due to the potential to compact soil. Extensions should be placed on all septic tank components to allow access to them from existing grade. Precast concrete tanks and distribution boxes should be used, unless plastic or fiberglass is required. Access to all tank compartments and distribution devices is optimal. INSTALLATION OBSERVATIONS ALL SERVICE septic, LLC must view the OWTS during construction. The OWTS observation should be performed before backfill, after placement of OWTS components. Septic tanks, distribution devices, pumps, dosing siphons, and other plumbing, as applicable, must also be observed. ALL SERVICE septic, LLC should be notified 48 hours in advance to observe the installation. LIMITS: The design is based on information submitted. If soil conditions encountered are different from conditions described in report, ALL SERVICE septic, LLC should be notified. All OWTS construction must be according to the county regulations. Requirements not specified in this report must follow applicable county regulations. The installer should have documented and demonstrated knowledge of the requirements and regulations of the county in which they are working. Please call with questions. Sincerely, ALL SERVICE septic, LLC Carla Ostberg, MPH, REHS Reviewed Richard H C C Pump Selection for a Non -Pressurized System -Single Family Residence Project 1948 Charlie Mt CDU Parameters 160 Discharge Assembly Size 1.50 inches Transport Length 50 feet Transport Pipe Class 40 Transport Line Size 1.50 inches Distributing Valve Modd None 140 Max Elevation Lift 10 feet Design Flow Rate 20 gpm Flow Meter None inches 'Add-on' Friction Losses 0 feet 120 Calculations Transport Velocity 3.2 fps Frictional Head Losses .w 100 Loss through Discharge 1.2 feet p=p Loss in Transport 1.2 feet 1— Loss through Valve 0.0 feet Lossthrough Flowmeter 0.0 feet 80 'Add-on' Friction Losses 0.0 feet p E Pipe Volumes w c Vol of Transport Line 5.3 gals 60 F Minimum Pump Requirements Design Flow Rate 20.0 gpm Total Dynamic Head 12.4 feet 40 20 9 10 20 30 40 50 60 70 80 Net Discharge (gpm) PumpData PF5005 High Head Effluent Pump 50 GPM, 1/2HP 11 5/230V 10 60H z, 2 00/23 OV 3 060 Hz eno System Curve:. Pump Curve:_ Pump Optimal Range Operating Point Design Point