HomeMy WebLinkAboutpitkin.eh.264514401001 (2002)Permit # 02079 Pitkin County Environmental Health Department Permit for an Individual Sewage Disposal System 0405 Castle Ck Rd, Aspen, Colorado 81611 Phone 970-920-5070 / FAX 970-920-5077 Parcel ID # 2645-144-01-001 Type of permit New( ) Repair( ) Addition to House(X) Name of Owner Patricia Nettleship Managing Partner Street Address 5720 Snowmass Creek Road Property legal description Size of lot 5 Water source # of bedrooms in house 5 Caretaker unit Attached # of bedrooms in caretaker unit Total square footage of the house # of offices, lofts & similar sized rooms in house Total square footage of the caretaker unit # of offices, lofts & similar sized rooms in caretaker unit Designed for what # rooms (list) New 2 bedrooms + 1 caretaker (existing 3 bedrooms on old system Permit # 79055) System NOT sized for lower floor exercise, TV & office rooms to be used as bedrooms. Permit information Designed by Church & Associates, Inc Mailing Address 4501 Wadsworth Boulevard, Wheat Ridge, CO 80033 Perc rate 8 mpi Profile hole depth 8ft Depth to groundwater or bedrock Septic tank capacity 1312 gallons minimum Absorption area Comments +8ft 514 sf : 50% red. =297sf Septic permit approved per compliance with the engineer design and specifications dated September 10, 2002. Any changes must be approved by this department and the design engineer prior to them being made. Minimum horizontal distances between components of the system and physical features shall conform to the Pitkin County ISDS regulations. Design is for a 1500 gallon two compartment concrete tank with effluent filter and equally distributed to 3 trenches, each one chamber wide and 7 chambers long for a total of 21 units. This department does not endorse any brand of products. The engineer must do a final inspection of the installation and submit an as -built letter to this department. This department must also be called for an inspection with a minimum of 48 hours advanced notice. Permit approved by: 21u, Date: 10 Plans and specifications of the proposed individual sewage disposal system have been reviewed and are considered satisfactory. Permission is hereby granted to the owner or the agent to perform the work indicated in accordance with the Pitkin County ISDS Regulation in effect at the time of issue. This permit becomes invalid 6 months from the date that the permit was issued unless system construction has commenced or an extension has been approved in writing by the Department. As -built drawings must be included with this permit before the final approval will be issued. Installer: Final Approval: vl[I /�),7 / 0 Z 1W V 0 4 1i Date: (baok) W PITKIN COUNTY ENVIRONMENTAL HEALTH DEPARTMENT APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM 0405 Castle Creek Road, Suite 10, Aspen Colorado 81611 Phone 970-920-5070/Fax 970-920-5077 Name of OWNER NFP III; Patricia Nettleship, Managing Partner Owner's Mailing Address P. O. Box 2488 City, State, Zip Yakima, Washington 98907 Business Phone: 310 454 5259 Home Phone: Local 970 923 8850 E-mail Address: pnettleship@nettleship.com Primary Contact Person (all communication regarding this permit will go through this person) Name Patricia Nettleship Company Same as above Contact Mailing Address City, State, Zip Business Phone Cell Phone: Fax : E-mail Address: Parcel ID # (available from assessor's office at 920-5160 or at www. itkinassessor.org)— Street address of property 5720 Snowmass Creek Road Legal Description: Lot Block Filing Subdivision Size of lot: 5 acres. Type of proposed structure: residence Total square feet of house # of bedrooms (potential) in house 5 Caretaker Unit: Attached ( 1 ) Detached ( ) Total areas . ft. of caretaker unit # of bedrooms(potential) in caretaker unit 1 Permit is for: New Horne ( ) Repair due to failure ( ) Remodel/Addition ( X ) Emergency use ( ) Water: Private well ( ) Spring ( ) Stream ( ) Community/Public Water System ( ) If community system: Name of system The fee for a ISDS application is $330 for a permit that takes 6 hours or less for the department to approve. If approval takes longer than 6 hours, a rate of $65 per hour will be charged. The maximum fee is $1000. The basic fee of $330 is due at the time of application. The remainder, if any, will be due in two stages: first, at the time of issuance of the ISDS permit; second, before final approval of the ISDS permit. Application for an individual sewage disposal system is hereby submitted. I hereby certify that the above information is true and accurate and that I have provided true and accurate information on locations of all existing and proposed wells, contour intervals, buildings, property lines, ditches, slopes, waterlines, springs, suction or irrigation lines, drinking water cisterns, drain tiles, irrigation ditches, lakes, water courses, streams, floodplains, dry gulches, and existing septic systems. I hereby certify that any such features not shown on attached site map are not present. Issuance of the permit does not imply the approval of any other permit required for construction pursuant to Pitkin County codes. No construction may be undertaken until all approvals and permits have been obtained. The Aspen/Pitkin Environmental Health Department, Pitkin County and employees of these agencies will be held harmless should the individual sewage disposal system fail or malfunction. The permit to construct is issued on information submitted,by the applicant or his/her representatives. The owner assumes full responsibility in case of failure of the system. Signature of applicant J _ Date Z Received by �� Receipt # .3 Fj Date 2- G:\isds\isdsapp\isdsapp.doc ` --jh� �� \ ���� • / ``� ` b��� \i� CHURCH December 6, 2002 Nettleship Family Partners III Attn: Tish Nettleship 5720 Snowmass Creek Road Snowmass, Colorado 81654 Associates, ENGINEERS & GEOLOGISTS Subject: Installation Observation, Nettleship Residence Remodel 5720 Snowmass Creek Road Pitkin County, Colorado Job No. 13709W Ms. Nettleship, RECEIVED APR 1 0 2003 PITKIN COUNTY ENVIRONMENTAL HEALTH As requested, we observed the installation of the onsite wastewater system for the subject site on August 7 and November 27, 2002. The system was designed under our Job No. 13709W, dated August 26, 2002 and revised September 10, 2002. The system includes the installation of a 1500 -gallon, two-compartment, precast concrete septic tank with a BiotubeTM pump vault in the second compartment. Four chamber -trenches and a three -outlet concrete distribution box were installed. Two trenches had 1 row of seven chambers each, one trench had 1 row of 4 chambers, and one trench had 1 row of 3 chambers for a total of 21 chambers and of 325.5 square feet of infiltrative area. To achieve even distribution, each outlet on the distribution box directed effluent to seven chambers. An as -built drawing is included as Figure 1. The PVC drain line for the water features should be monitored for signs of odor or effluent, in the unlikely event of a broken sewer pipe. I The components of the OWS were installed in conformance with our plans and specifications. Sincerely, CHURCH & Asso ' s, Inc. Timothy R. Petz Project Manager TRP/erb 2 copies sent Copy to PCEHD, Attn: Nancy MacKenzie DENVER 4501 Wadsworth Boulevard Wheat Ridge, CO 80033 303.463.9317 Fax: 303.463.9321 Reviewed by Edward O. Church, P.E. LOT 1, HIDDEN MEADOWS PITKIN COUNTY, COLORADO PVC DRAIN LINE ' FOR WATER FEATURES- . � WELL APPROXIMATE LOCATIONS OF EXISTING SEPTIC TANK AND DRAIN FIELD 325.5 SF OF INFILTRATIVE AREA IN 3 GRAVELLESS CHAMBER -TRENCHES. TWO TRENCHES HAD ONE ROW OF 7 CHAMBERS EACH, ONE TRENCH HAD ONE ROW OF 4 CHAMBERS, AND ONE TRENCH HAD ONE ROW OF 3 CHAMBERS FOR A TOTAL OF 21 CHAMBERS. SCALE 1"=20' l EXISTING RESIDENCE AND PROPOSED ADDITION EANOUT 1500 -GALLON, TWO-COMPARTMENT, PRECAST CONCRETE SEPTIC TANK WITH A BIOTUBE- PUMP VAULT IN THE SECOND COMPARTMENT. �-2" PVC PUMP LINE 3 -OUTLET CONCRETE DISTRIBUTION BOX AS -BUILT DRAWING 12/06/02 JOB NO. 13709W FIGURE 1 Pitkin County Environmental Health Department Contact Log Sheet Name: .� z - Parcel ID#: Address: ate Person Spoken To Comments /.Action to be Tak n Initials Time 0N � tc� nof,n�lacf�ar �. n WI&q& 7 %i!n 4,lt�teOc he, 0--,, Y/ by (3 Du7�ce fs tn YGu J bex jac -CGS. Laol -�- Airc� 93,/. 6,AL �o -tGu, nVw�a�r. /V O i sung w ��1� waw s v u rcz iia vk 6r V`f�e�t r� ��s(�G�Ct��O, 1 inn will �iod aonywhw �&1 I�ry h,ctrs 4 kcuw`\---f -1 V-11 Uil,t, Jn.0W oA6-�A 4Gu v1.Q w v1iit bi"rvt h ,WA Of /10 � 7�6. lrY/// need 6) k 'al Oc+4ed. 0 In To: "'nancym@ci.aspen.co.us " <nancym@ci.aspen.co.us> Subject: Tish Nettleship. Perc tests around the drain field at Tish'es house did not go great due to the backfill used around the original drain field. It was clay fill. I would like to assess the existing drain field based on the LTAR of the recieving soils, and not the perc test. Is this a feasable procedure? Happy Friday! T Printed for Nancy MacKenzie <nancym@ci.aspen.co.us> rQ Page 1 of 1 05/20/2002 Tim Petz, 03:51 PM 04/29/2002, Re: Tish Nettleship To: Tim Petz <tpetz@geo-church.com> From: Nancy MacKenzie <nancym@ci.aspen.co.us> Subject: Re: Tish Nettleship Cc: Bcc: Attached: We dont count on anything that Bob Nelson did! Yes, you need to redo the tests for an expansion. You got a lot faster rates in different area as I remember. --what does Ed say about perc tests near an existing field?-- And what do we do about the existing field size if you get faster perc rates right next to it???? Won't it be nice to get Tish done one of these years! At 03:22 PM 04/29/2002, you wrote: I want to investigate existing drain field to determine perc rates and to see if drain field is functioning. Is it practical to do a perc test around existing field to determine rates ---and then incorporate that drain field into the new 'upgrade' system? There was a perc test performed by Nelson in 1979, with an average of 46 mpi. Basically I am asking if Mr. Nelsons peres are set in stone, or can I go back and verify and size accordingly. Signed Geologist playing an engineer, Tim Petz Printed for Nancy MacKenzie <nancym@ci.aspen.co.us> At 11:45 AM 07/03/2001 , you wrote: Question for you. I have a client whom wants to dispute original perc rates perfomed by Bob Nelson. The address is 5720 Snowmass Creek Road (nancy is familar). The field has been in for 15 years or so. Bob peres were 46 mpi. I got much better rates about 100 feet away. Client wants to re-perc existing field to get more credit for it. I have tried to explain to client, they will not listen to my reasoning. They want me to ask you. Permit # is 79055. The soil is good, it is alluvial material deposited by Snowmass Creek told the client I would touch base with you. I am sure we are thinking the same thing. (but I will let you answer) Tim No, I would not think we would give credit for an existing field size at another perc - mainly because it is 15 years old. Plus, the original sizing would be undersized for today's standards, and if they were doing an addition - they would have to bring that up to code anyhow. What is the last name on that? I have not heard from them yet. If you get me the parcel ID I can pull the file. cb I c C -I ASPEN/PITKIN r-NVIRONMENTAL HEALTH DEPARTMENI ISDS DESIGN REQUIREMENTS -DEPARTMENT USE ONLY Name Nettleship House Size (75 gpd, 100 gpd, or 130 gpd) #of Bedrooms, Similar Rooms accessible to baths in Main Residence # of Bedrooms, similar rooms w/ access to bath in ATTACHED caretaker # of Bedrooms & Similar Rooms w/ access to baths in DETTACHED caretaker Average Daily Waste Flow 450 # bedrooms X 2 people/br X 75 State Review Required? no Perc Rate 46 (T) 3 equals # of Perc Holes Required Design Flo w (Q) = # bedrooms X 2 people/bedroom X gpd X 1.75 Q= 1050 Minimum tank capacity 1313 gallons Absorption Area (A= 0/5 X SQRT) A = 1424 sq. ft. of absorption area required 92 infiltrator units without reduction A maximum 30% reduction is allowed for use of deep gravel or gravelless chambered system. 997 sq.ft. with reduction 64 infiltrator units with reduction AREA NEEDED FOR STANDARD ABSORPTION TRENCHES 475 1424 Total sq ft /3 =lineal ft of trench needed 100 3 8 475 lineal ft/assumed trench length of 60ft = # of 60ft trenches needed 7 # trenches minus 1 = rows of 6ft wide undisturbed soil between trenches 24 8 times 3 = total width of of 60" long field needed for just the trenches 42 7 times 6' = total width of 60' long field needed just for undisturbed soil 66 width of trench +width of undisturbed soil = total width needed 66 by 60 ft is the area needed for a standard absorption field in a trench configuration with no reductions taken and ASSUMING AN AVERAGE PERCOLATION RATE OF 46 SLOWER PERCOLATING SOILS WOULD REQUIRE MORE AREA. SETBACK FROM WELL SETBACK FROM POND, STREAM OR IRRIGATION DITCH # of feet = 104 # of feet = 54 SETBACK FROM DRY GULCH # of feet = 29 Remember: 8 feet of additional distance for each 100 gallons/day of design flow over 1,000 gallons/day should be added unless an RPE can verify that it is not necessary to prevent contamination. 1/20/99 Printed on Recycled Paper B9N1 sheet no. name B9��liYl� number e9z�1. cRv .,, f� OF Pitkin county EIloiroomefitalHealth March 20, 2003 Patricia Nettleship PO Box 2488 Yakima, WA 98907 Re: Parcel ID #2654-144-01-001 Property Address/Legal Description: 5720 Snowmass Creek Road Dear Mr. Nettleship: This letter is to advise you that Environmental Health has not been able to complete the processing of the Individual Sewage Disposal System (ISDS) permit for the above stated residence/property. It is mandatory that our office receives an "As Built" letter from the engineer who designed the system. The letter will confirm that they observed the installation of the, system as designed. Any changes to the system must be noted in the letter or by a new set of plans. The Building Department will not issue a Certificate of Occupancy for this property until they are notified that the ISDS permit process is complete. This office must receive the "As Built" letter from the engineer no later than 30 days from the date of this letter. Please contact me with any questions. Thank you in advance for your help and cooperation in this matter. Sincerely, Carole Twitchell Pitkin County Environmental Health cc: Church & Associates 0405 Castle Creek Road, Suite 10 Aspen, Colorado 81611 (970) 920-5070 fax 920-5077 www.pitkingov.com �--,dW p.W Tish Nettleship, 02:16 PM 10/1 f 102 , Permit issued From: Tish Nettleship <pnettleship@nettleship.com> To: "'beths@ci.aspen.co.us"' <beths@ci.aspen.co.us> Cc: "'tpetz@geo-church.com"' <tpetz@geo-church.com>, "'nancym@ci.aspen.co.us"' <nancym@ci.aspen.co.us>, "'aspendigger@aol.com"' <aspendigger@aol.com> Subject: Permit issued Date: Fri, 18 Oct 2002 14:16:18 -0700 X -Mailer: Internet Mail Service (5.5.2653.19) X-ECS-MailScanner: Found to be clean Dear Beth: Tim Petz spoke with Nancy who told him that the permit had been issued last Friday. Terrific. Jinx of Aspen Diggers is the contractor for this work. He would need the permit and the copy of the plan that is required to be kept on the jobsite. (I'm in California and do not have his address for sending the plans. I'm not sure if it's his intent to pick them up at your office or have you mail them to him. Aspen Diggers is listed in the phone book, I hope with an address. No phone book here unfortunately.) I've copied Jinx, and Tim, and Nancy on this e-mail. Nancy, thank you for all the help you've provided on this. You have been a pleasure to work with. Tim: That goes for you too. Page -Y V5. cl�1 Printed for Beth Seeman <beths@co.pitkin.co.us> 10/21/2002 CHURCH & Associates, Inc. ENGINEERS & GEOLOGISTS September 10, 2002 Nettleship Family Partners III Attn: Tish Nettleship 5720 Snowmass Creek Road Snowmass, Colorado 81654 Subject: Subsurface Investigation and Upgrade OWS Design, Nettleship Residence Remodel 5720 Snowmass Creek Road Pitkin County, Colorado Job No. 13709W Ms. Nettleship, As requested, we investigated subsurface conditions at the site and designed an onsite wastewater system (OWS) upgrade for the remodel. The previous design dated August 26, 2002 should be discarded to avoid confusion. The subsurface investigation was performed on May 29, 2001. SITE CONDITIONS The property is in a rural residential area of Pitkin County, where OWS are required. The existing residence intends to convert three existing rooms to three bedrooms. The additional bedrooms will serve a separate OWS. A separate stub -out will be needed to serve the proposed OWS. The existing septic tank and drain field will remain in use. There is a lined water feature 10 feet south of the southeast corner of the house. The proposed drain field area has a 2% slope to the west and a moderate cover of native grasses. The site is supplied water by a well, located 102+ feet from the proposed drain field. CONSTRUCTION A remodel completed in 2001 created additional area for conversion of three rooms to bedrooms. The total living area is 5000 square feet (SF). The three additional bedrooms will be served by a separate OWS, as indicated on Figure 1. The OWS was sized based three bedrooms and 600 gallons per day (GPD) using Pitkin County Environmental Health Department (PCEHD) loading of 100 gallons per day per person. The loading with a peaking factor of 1.75 is 1050 GPD. This includes washing machines and garbage grinders. SUBSURFACE CONDITIONS A subsurface investigation was performed b digging three percolation holes, 37 to 44 inches deep, and one profile pit at the locations_ indicated on Figure 1, Subsurface materials in the profile pit consisted of 1.5 feet of sandy topsoil, underlain by slightly clayey sand with gravel and boulders to the maximum depth explored of 8 feet. No ground water was encountered. Percolation tests indicate percolation rates of 5 to 10 minutes per inch (MPI). The average rate is 8 MPL Percolation data is presented in Table 1. Additional percolation tests were performed in the area of the existing field. The results are not relevant to this design. RECONEMENDATIONS The installation requires a septic tank and three chamber -trenches at the locations presented on Figure 1. The OWS design is based on an average sewage load of 600 GPD and a percolation rate of 8 MPI. The DENVER 4501 Wadsworth Boulevard Wheat Ridge, CO 80033 CASTLE ROCK 303.660.4358 EVERGREEN 303.816.1455 303.463.9317 Fax: 303.463.9321 LOVELAND 970.663-2124 WESTERN SLOPE 970.948.5803 Subsurface Inve tion and Upgrade OWS Design Job No. 13709W, 9/10/02 `t I Page 2 installation includes one 15\/00 -gallon, two-compartment, precast concrete septi tank, tanthree chamber - trenches. Each trench must have one row of seven chambers for a total of 21 chambers. A flow splitter basin or a concrete distribution box is required to distribute effluent. Trenches must be installed within four feet of the ground surface. If gravity discharge cannot be achieved we must be contacted for pump details. Vehicle movement over the drain field area during construction should be kept at a minimum to minimize compaction of the receiving soils. The bottom of the bed should be scarified with a pick, shovel, or backhoe bucket teeth prior to the addition of chambers. The surface of the field should be seeded after installation of the fields. A native seed mix should be sown at the drain field to revegetate the surface. These mixes do not require irrigation and develop a growth 10 to 15 inches high. No automatic sprinkler system should be installed over the fields. OPERATION AND MAINTENANCE The owner realizes an OWS is different from public sewer service. The owner must assume responsibility for maintenance of the system. In the absence of a monitoring program, the septic tank should be pumped every two years. Effluent filter and screened vaults, as applicable, are to be cleaned during pumping. There are daily considerations such as not putting plastic or other nonbiodegradable materials into the septic system. Garbage disposal use should be minimized. The backwash of a water softener may be harmful to the OWS. A separate drywell should be constructed for the backwash waste, if a softener is installed. Chemically treated water from a swimming pool or spas should not be introduced to the OWS. LIMITATIONS An OWS design should be installed by a contractor who is experienced in its installation. Our investigation, layout, design and recommendations are based on data submitted. If subsurface conditions different from those described in this report are encountered, we should be notified to evaluate the change on the proposed OWS. If the health department modifies this design, we should be contacted to evaluate the impact on the performance of the OWS. The county and our firm must be contacted upon completion of the OWS All construction is to be in accordance with the ISDS regulations. Pipe type and size, burial requirements, septic tank construction, and other specifications, which are not depicted in our report, are to conform to the requirements of the ISDS regulations. The installer of the system is to have demonstrated knowledge of the PCEHD ISDS regulations and requirements. If there are questions, please call. The project engineer for this site is Tim Petz.,Do Re"� CHURCH & Associates, Inc. Timothy R. Petz Project Manager TRP/erb 3 copies sent, via FED EX 0tL0. Reviewed by P 0 1 13172 t 6 Edward O. Church, P.E. kP Oct 10 02 01:34p co 9 p �pypa rm°�u'i zSwo ��- 46 ZTX �u �24 ow¢ rnp p.2 Oct 10 02 01:35p N (n W ---- W LUZ Z_ I Z O —} Q O% 1-- LL! ~W Z D � Z�-=` ' L1_ ' CL 4 0 zix�F— O Wu O Q Z - U CL J� f- Lij D Q O Lu w U_ � ZLU ~ � Qo no ti a_ p v Q � m LJ cw o L l p.3 K 'LOT 1 HIDDEN MEADOWS PITKIN COUNTY, COLORADO JOB NO. 13709W ATE LOCATIONS /EXISTINGRESIDENCE I G SEPTIC TANK ,. _ • F AND DRAIN FIELD. '. r • ; d04 ,WELL , CLEANOUT • � ,•,'. rip°`� �', „ 4" PVC SEWER LINE 1500 -GALLON, • ,� TWO-COMPARTMENT, PRECAST' CONCRETE SEPTIC TANK WITH'. 325.5 SF OF INFILTRATIVE AREA y. AN EFFLUENT FILTER ON THE i f OUTLET. IN 3 GRAVELLESS 102' SETBACK TO Q , CHAMBER -TRENCHES. EACH WELL Q DISTRIBUTION TRENCH MUST HAVE ONE ROW OFVX DEVICE 7 CHAMBERS FOR A TOTAL OF 21 �/ _ CHAMBERS. 1 THE LOCATION OF EXISTING AND PROPOSED IMPROVEMENTS SHOWN HEREIN; AND THE WELL AND/OR DRAIN FIELD LOCATIONS STAKED AT THE SITE; ARE NOT THE RESULT OF A PROPERTY SURVEY, IMPROVEMENT LOCATIONS ARE APPROXIMATE. IT IS THE PROPERTY OWNER'S RESPONSIBILITY TO DEFINE PROPERTY BOUNDARIES AND ENSURE ALL ONSITE IMPROVEMENTS ARE LOCATED WITHIN THE PLATTED SITE AND OUT OF INAPPROPRIATE EASEMENTS. ALL SEPARATION DISTANCES ARE TO BE VERIFIED PRIOR TO EXCAVATION. SITE PLAN, LOCATION OF PERCOLATION HOLES, AND LOCATION OF PROPOSED OWS SCALE 1"=60' 9/10/02 FIGURE 1 TYPICAL PLAN VIEW - N.T.S. EFFLUENT INLET (1/8" PER FOOT DROP) TYPICAL CROSS-SECTION - N.T.S. ACKFILL 4' EXTENT OF EXCAVATION LOW SPLITTER BASIN 4" SDR 35 PVC OBSERVATION/VENT PIPE WITH CAP 4" SDR 35 PVC OBSERVATION/VENT PIPE GRAVELLESS CHAMBER 3' BY 6.25' ----43.75' TOTAL - THREE TRENCHES SLOP ' MIN, FOR DRAINAGE 1.5' MIN GRAVELLESS CHAMBER 3' BY 6.25' CALCULATIONS AND SPECIFICATIONS DESIGN CRITERIA LOADING RESIDENCE REMODEL = 3 BEDROOMS, <6000SF LOADING = 100 GAL/DAY/BED TOTAL LOADING = 600 GPD PERCOLATION RATE = 8 MPI AREA = ((1.75 X 600) X sqrt 8)/5 = 514 SF 50% REDUCTION FOR INFILTRATORS = 297 SF JOB N0. 13709W IN FLOW SPLMER BASIN FOR GRAVITY FLOW EFFLUENT TOP VIEW TRENCH SPECIFICATIONS NUMBER OF TRENCHES — 3 LENGTH OF EACH TRENCH — 43.75 FEET, 7 CHAMBERS WIDTH OF EACH TRENCH — 3 FEET, 1 CHAMBERS TOTAL NUMBER OF CHAMBERS — 21 CHAMBERS TOTAL AREA — 325.5 SF DRAIN FIELD DETAILS SIDE VIEW FINAL GRAD t , 1D SY 1 30" 4' -PVC INFLUENT FROM 4, DOSING TANK FIBERGLASS UO WITH STAINLESS STEEL BOLTS & URETHANE GASKET. PVC BASIN PVC DISCHARGE PIPE EFFLUENT DISCHARGE, Ot SAE 'SPEED LEVELER' TREATMENT UNIT SPECIFICATIONS TOTAL MINIMUM CAPACITY — 1.75 X q X (30 HOURS/24. HOURS) = 1312 GALLONS RECOMMENDATION — ONE 1500—GALLON, TWO—COMPARTMENT, PRE—CAST CONCRETE SEPTIC TANK WITH AN EFFLUENT FILTER 9/10/02 N E M m cm coF. n • ` 8 w C D LLti Cc .c �. w T E E;w. O d o i o q E �..7 -0-0 d N �o 20 0� m m LM 3 Ym C.2 'a =� v v+ w m (L xo an— tY vv o m m .1-1m �� 300 V) rL G3 $'' E .�-� a° c c c U o U v $ O C O U -02 00 o c c W 3 .. Fp- L?L Civ F�.�. F -v >.W > CZ tr_ m U � ( o gU co ^ _ 4-1 E 0f CD - } U E j En No ------ _=3 () � owa WaNz uj ® r ion CL in Ua U �O ari ! cn ot&n0 ■ a D Ev M U _. �� -- cl .-. v E Y v v v M cCD> 4:3 E! 0-6M�cn 0 c -v `v+ v Q n ai _ v o �i v 0 0 Q o aai O n c .t c v a+i a C co i C 2 O U O=J Fes- C C j1 0 o Co Lf)i.L O opCD /� d M WL Li 7 /'1 T ® O 7 Profile, TABLE 1 - PERCOLATION TEST RESULTS 5720 Snowmass Road Snowmass, Colorado faa# Aacrrinfinn DATE OF TEST: 5129/01 0-1.5' Topsoil, sandy; root zone 1.5'-8' Sand, slightly clayey, with gravel & boulders; dense; moist; red/brown NO GROUND WATER WAS ENCOUNTERED WITHIN THE EXCAVATION AVG. HOLE DEPTH TIME DEPTH DEPTH CHANGE, INTERVAL HOLE NUMBER OF HOLE, INTERVAL START, END, (INCHES) pERC PERC. (INCHES) (MINUTES) (INCHES) (INCHES) RATE (MPI) RATE, imp]) 1 37 10 3.00 5.50 2.50 4 4.00 10 4.75 7.00 2.25 4 2.25 10 5.50 7.75 2.25 4 1.25 10 3.00 5.00 2.00 5 7 10 4.00 6.00 2.00 5 10 1 4.50 6.50 2.00 5 5 3 44 10 1.25 4.00 2.75 4 10 4.00 6.00 2.00 5 10 1.50 2.25 0.75 13 10 225 3.50 1.25 8 10 3.50 5.00 1.50 7 10 2.00 3.25 1.25 8 8 .lob NO. 13709W Oct 10 02 01:34p P.1 low CHURCH & Associates, CtUInc. ENGINEERS & GEOLOGISTS IL) --tr; -- c- —, -. "\j Cy --C A Vie7CL- 40-) DENVER 4501 Wadsworth Boulevard Wheat Ridge, CO 80033 303.463.9317 Fax: 303.463,9321 Engineer's Submittal for Septic Permit in Pitkin County Owner's Last Name: Nettleship Familyarters III Location: 5720 Snowmass Creek Road Summary of information regarding new septic system: Type of system being proposed: GRAVELLESS CHAMBER -TRENCHES Other treatment processes being used: EFFLUENT FILTER Does the system use any mechanical parts? (Prohibited unless there is no alternative) NO If yes, explain why there are no alternatives Does the system require any maintenance other than routine pumping? YES If yes, who will do the maintenance? CLEAN FILTER WHEN SEPTIC TANK IS PUMPED Are any reductions being proposed? YES If yes, what makes the lot and soil conditions optimal? GOOD PERCOLATION RATES AND PROPOSING TRENCHES Which of the following are on the site or within setbacks? Closest distance of septic system to each feature 100 year floodplain N/A [X] well(s) 102 FEET [] irrigation ditches N/A (X] streams 52 FEET ponds NLA other N/A What was the profile hole depth? 8 FEET What is the depth to groundwater? What is the depth to bedrock? NNA. What assumptions, if any, were made in system sizing and design? (Include any local, site- specific data, such as months without snow cover, ratio of evaporation to absorption, etc. that are relevant,) If there are any variations from normal design, please explain how they can be demonstrated to improve treatment and protect water quality. NONE ASPEN/PITKIN ENVIRONMENTAL HEALTH DEPARTMENT ISDS DESIGN CALCULATIONS Owner's Name��t�'�#`!E��� �� � �Y,� T' Parcel ID # House Size (sq. ft) SOtiF (75 gpd, 100 gpd, or 130 gpd) 100 Number of Bedrooms in Main House ho4 1 Em Number of Offices, Libraries, Studies, Similar -sized Rooms in Main House (There is the potential for 3 bedrooms due to conversion) Number of Bedrooms in Detached Caretaker unit, h'1ME+93 Number of Offices, Studies, Similar -sized Rooms in Caretaker Unit" r (If the caretaker unit is ATTACHED, treat as if part of main house.) Average Daily Waste Flow 600 State Review Required? no Perc Rate (T) Design Flow (Q) = # potential bedrooms X 2 people/ bedroom X gpd X 1.75 Q= 1050 Absorptior Area (A= Q/5 X SQRT) A = 594 sq. ft. of absorption area required 38 infiltrator units without reduction A maximum 50% reduction is allowed for use of deep gravel or gravelless chambered system, only if the lot size and soil conditions are optimal. If a reduction is being proposed, describe why lot size and soil conditions are optimal: GOOD SOIL CONDMONS AND PROPOSING TRENCHES A = 297 sq.ft with reduction 19 infiltrator units with reduction Type of system: [}Absorption trenches UAbsorption bed [x] Gravelless chambers aDry well OSeepage Pit QOther Minimum tank capacity 1313 gallons SETBACK FROM WELL # of feet = 102 SETBACK FROM POND, STREAM OR IRRIGATION DITCH # of feet = 52 - SETBACK FROM DRY GULCH # of feet = FINAL INSPECTION" BY: DATE: awl t mi c /Vove,6 1,98,5 sA ecr, 01? IT V4*. • 0 0 v, :TO, IL 9 I I I I ------------ L W yETTLE5HIp RE51DENCE ° P N F7-21-- o LIPKIN WARNER DESIGN & PL e 5720 SNOWMASS CREEK ROAD 234 9TWORIVERSRDW/•I T° L W D P LIPEN WARNER DESIGN & PLANNING I%- Op20 I tna�l coal SAO' ahyl y 00 I 1 m I ? I� n o w ti n2� 2 T o n�2 po Z hh p Z 2 � 22a p Jaz o ti 2 Ch 2 a y a� h h h a y n 41'i1 2 y"y Y '-) 0 h p�OZ p OO^2i r�r+�� oAn�•^yi� ��y2 �h00'C �U Oj tj -13 Oi 2002 nhh pa�Zr�� a yZ72 ^l y�1 n7' � y`�OCO 22hab� a 0 �� "i�^�pL 2 mr Z p0 �1 •C H•[• k^7 �2on C 21% _�nZ .�jpy^�iry �Om�^2i 2�=�ain �ypoy n^�io�'^ ~�nh pyhoo� pada �5222� a22� p n p OOn T � 22yy0 p�y� 2^icyp n'ca02 y^ly0 �r�,A� y O2p�0 ^i2�Z a � opo y O 20ar�C � h O�^iy0 ��Oa Z<hOT� OOVa1 o���T2� �'hikA2p �ym� S o(z ft ago ya2pr p�hp 2 p � 22a o pam P"PANT FDR• P.4TRrM ArSTTLESHIP ,2665111.4IN ST. STA' ,Z20 SXjVT4 VOA'1M4, Q 90-4405 _n_ ITIL ESMT. job number 89241 &9241TOP sheet no. drawing number coord file number : 89241. CRD 1 drownby. A01 OF Date 4/8/98 -- i ,bt5 LVL H11 11-1J 0 0 0 0 SCARROF & #Ar LKER INCORPORATED Registered Laud Surveyors 818 Colorado Avenue Glenwood Springs, Colorado 81601 (303) M-8664