Loading...
HomeMy WebLinkAboutpitkin.eh.264514101002 (2002)Permit # 02025 Type of permit Name of Owner new home Pitkin County Environmental Health Department Permit for an Individual Sewage Disposal System 0405 Castle Creek Road, Suite 10, Aspen, Colorado 81611 Phone 970-920-5070 / FAX 970-920-5077 Parcel ID # 2645-141-01-002 Bradlev L. Zanin Street Address 5084 Snowmass Creek Road Snowmass, CO Property legal description Lot B, Snowmass Trust Size of lot Water source 8.207 acres Total square footage of the house Private well # of potential bedrooms in Caretaker unit 4 Total square footage of the caretaker unit # of potential bedrooms in caretaker unit Designed for what # rooms (list) 4 Permit information Designed by High Country Engineers 923 Cooper Ave GWS 81601 Perc rate 31 Profile hole depth 8ft Minimum Septic tank capacity 1750 Depth to groundwater or bedrock Minimum Absorption area Comments +8ft 1559/50%reduction=779sq ft Septic permit approved per compliance with the engineer design and specifications stamped 5/1/02. Any changes must be approved by this department and the design engineer prior to them being made. Minimum horizontal distances between components of the system and physical features shall conform to the Pitkin County ISDS regulations. ` ^ 6aa(r _ j 6 � k .,,4, g f 13 UZ Engineer design is for a 1750 gallon two cco-mppa-rtment septic tank with a filter. 50% reduction is taken for infitrator in trench configuration. 5 trenches/total of 51 units. This department does not endorse any brand of products. This permit must be kept on-site during installation. The engineer must do a final inspection of the installation and submit an as -built letter to this department. This department must also be called for an inspection with a minimum of 48 hours advanced notice. Permit approved by: Date: e G' Plans and specifications of the �osed individual sewage disposal system have been reviewed and are considered satisfactory. Permission is hereby granted to the owner or the agent to perform the work indicated in accordance with the Pitkin County ISDS Regulation in effect at the time of issue. This permit becomes invalid 6 months from the date that the permit was issued unless system construction has commenced or an extension has been approved in writing by the Department. As -built drawings r Installer: included withAhis permit before the final approval will be issued. Final inspection approval: Date: -J� PITKIN COM' ENVIRONMENTAL HEALTH DEPA[ 'Ir -NI APPLICATION FSR INDIVIDUAL SEWAGE DISPOSAL a YSTEM 0405 Castle Creek Road, Suite 10, Aspen Colorado 81611 Phone 970-920-5070/Fax 970-920-5077 Name of OWNER ���� y L - ,Z VVin-) Owner's Mailing Address S C'tN1E%FY��` � L ✓� S�CfL CLQ "V60 Business Phone: 34K lz� Home Phone: Primary Contact Person (all communication regarding this permit will go through this person) Name I --�7AkG,6Y Company Contact Mailing Address -s- Ca6W7,w zv)0 hs� C16 91611 Business Phone : Cell Phone : Fax: q 5 — '� '�9 3 Parcel ID # (available from assessor's office at 920-5160 or at www.aspen.com/assessor/) Street address of property Legal Description: Lot Block ,2 O b Z ;1,n�5 �iZ£�� jZl, SN�i(1rL1�i•5S . CC> �l� Sy ,Filing Subdivision S1\4 WAt)Y1S Size of lot: "3• Z04 acres. Type of proposed structure: /7 Size of bldg. envelope Total square feet of house '1 060 # of bedrooms in house `t # of offices, lofts & similar sized rooms in house Caretaker Unit: Attached ( ) Detached ( &ooms in caretaki Total area(sq. ft.) of caretaker unit lofts and similar size rooms of caretaker unit t0a / Permit is for: New Home Repair due to failure ( ) Remodel/Addition ( ) Emergency use ( ) Water: Private well (✓) Spring ( ) Stream ( ) Community/Public Water System ( ) If community system: Name of system The fee for a ISDS application is $330 for a permit that takes 6 hours or less for the department to approve. If approval takes longer than 6 hours, a rate of $55 per hour will be charged. The maximum fee is $1000. The basic fee of $330 is due at the time of application. The remainder, if any, will be due in two stages: first, at the time of issuance of the ISDS permit; second, before final approval of the ISDS permit. Application for an individual sewage disposal system is hereby submitted. I hereby certify that the above information is true and accurate and that I have provided true and accurate information on locations of all existing and proposed wells, contour intervals, buildings, property lines, ditches, slopes, waterlines, springs, suction or irrigation lines, drinking water cisterns, drain tiles, irrigation ditches, lakes, water courses, streams, floodplains, dry gulches, and existing septic systems. I hereby certify that any such features not shown on attached site map are not present. Issuance of the permit does not imply the approval of any other permit required for construction pursuant to Pitkin County codes. No construction may be undertaken until all approvals and permits have been obtained. The Aspen/Pitkin Environmental Health Department, Pitkin County and employees of these agencies will be held harmless should the individual sewage disposal system fail or malfunction. The permit to construct is issued on information submitted by the applicant or his/her representatives. The owner assumes full responsibility in case of failure of the system. Signature of applicant Received b) Receipt # 3- G:\eh\isds\isdsapp\isd�p.doc Date /D Date% / u GY J C) r mow► _ F 7 t , L3 J. w i w �" •4 s# Y w . x a t s # } x q 1 � w ' #�# 0 + ,AL tk �,1 1, ! ` . ��'+" {' �� ' �.•, _� � ��, ,, t,� � tip- � � � ` ''��� lw a 1 Pitkin County Environmental Health Department Contact Log Sheet Name: r ParcelID#: ( Address: ate Person Spoken To Comments / Action to be Taken Initials Time RYMM WAS M W-1 7,11, Am 9 W; 0, W-00, I M. M FUR I I NO M ASPEN/PITKIN ENVIRONMENTAL HEALTH DEPARTMENT ISDS DESIGN CALCULATIONS Owner's Name Parcel ID #' House Size (sq. ft.) 1 4000 (75 gpd, 100 gpd, or 130 gpd) Number of Bedrooms in Main House Number of Offices, Libraries, Studies, Similar -sized Rooms in Main House Number of Bedrooms in Detached Caretaker unit Number of Offices, Studies, Similar -sized Rooms in Caretaker Unit (If the caretaker unit is ATTACHED, treat as if part of main house.) Average Daily Waste Flow 800 State Review Required? no Perc Rate 31 (T) Design Flow (Q) = # potential bedrooms X 2 people/bedroom X gpd X 1.75 Q= 1400 Absorption Area (=Q/5 X SQRT perc rate) A = 1558.974 sq. ft. of absorption area required 101 gravelless chamber units without reduction # of Perc Holes Required: 3 1 in every soil type? Spaced uniformly over proposed area? A maximum: 50% only if the lot size and soil conditions are optimal. If a reduction is being proposed, describe why lot size and soil conditions are optimal: A = 779.48701 sq.ft. with reduction 50 gravelless chamber units with reduction Type of system: []Absorption trenches []Absorption bed [] Gravelless chambers []Dry well []Seepage Pit []Other (type) Minimum tank capacity 1750 gallons SETBACK FROM WELL # of feet = 132 SETBACK FROM POND, STREAM OR IRRIGATION DITCH # of feet = 82 SETBACK FROM DRY GULCH # of feet = 57 Printed on Recycled Paper 100 t Co NN Cw >T� �20� I � � ST10 wNl �S C�ZELI /oc) S No wMCPao_ Q L. L��cj � S�vou�r�t�5 S SNvwC-6 C,z62!�Ic- /,Z/t 1� <�/� S9 ��e95 �9I v�-ooh GO June 28, 2002 Carla Block Pitkin County Environmental Health 0405 Castle Creek Rd., Ste. 10 Aspen, CO 81611 Re: Zanin ISDS — 5084 Snowmass Creek Road HCE File Number 2021039.59 Dear Carla: o RECEIVED JUL 0 3 2002 PITKIN COUNTY ENVIRONMENTAL HEALTH On June 28, 2002, High Country Engineering personnel observed the construction of the ISDS for the Zanin Residence, 5084 Snowmass Creek Road in Pitkin County, Colorado. One 2000 -gallon septic tank with baffle, a distribution box and 51 standard Infiltrator units had been installed in a parallel trench configuration. Minimal backfilling had taken place. The installation of the system was in conformance with the intent of the design and I have enclosed pictures of the system for your convenience. If you have any questions, or need additional information, please contact us. Sincerely, HIGH COUNTRY ENGINEERING, INC. Roger D. Neal, P.E. Project Manager RDN/djw 1517 Blake Avenue, Suite 101 Glenwood Springs, CO 81601 Telephone (970) 945-8676 - Fax (970) 945-2555 yp REG/ST t 23975 0. ............ 14 Inverness Drive East Suite D-136 Englewood, CO 80112 Telephone (303) 925-0544 - Fax (303) 925-0547 1 � , I I I F110 WNESPEC (TTYOPN LL . ) I I ! (7YP ) I \ I I ! CLEANOUT ! 2000 -GAL.! SEPTIC TANK I —AND DISTRIBUTION BOX W l FOUR 9� __17 I BEDROOMHOUSE i C-90 fel 11 \\� T. l(l+/� i e � ' / e 1 / I Jill GRAPHIC SCALE (IN FEET) I inch = 40 ft 1. ABSORPTION LATERALS SHALL NOT EXCEED 100 FEET IN LENGTH. 2. THE BOTTOM OF EACH ABSORPTION TRENCH SHALL BE LEVEL. 3. DRAINAGE SWALES ARE TO BE PROVIDED ABOVE AND AROUND TRENCHES, AS NECESSARY, TO PREVENT SURFACE RUNOFF FROM ENTERING ABSORPTION AREA. 4. TRENCH LATERALS SHALL FOLLOW CONTOURS. S. INSTALL INFILTRATOR IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. 8. TRENCH BOTTOM AND SIDEWALLS MUST BE RAKED TO REMOVE SOIL SMEARS INCURRED WRING EXCAVATION. 7. NO EXCAVATION OF ABSORPTION FIELD IS TO BE DONE DURING WET WEATHER AND USE OF RUBBER TIRE VEHICLES OVER ABSORPTION AREA IS PROHIBITED 8. BOULDERS EXISTING WITHIN THE TRENCH SHALL BE EXCAVATED AND BACKFILL SHALL CONSIST OF ONSITE SELECT OR PIT -RUN MATERIAL. 9. IN ALL TRENCH CONFIGURATIONS, SERIAL DISTRIBUTION SHALL BE USED INSTEAD OF EWILATERAL DISTRIBUTION TO INCREASE SETTLING TIME AND PROTECT THE BACTERIAL BIOIAAT. 0 z _z w8 [Z� QAO "' aZi� W $ W 2 LL cr 51 Z� o Zhu Vin M �giE PROJECT NO. 2021()39.00 SHEET 1 �IVCwpw 111-2000' SCALE: 1. yi�r�O ALL CONSTRUCTION SHALL BE ISN ACCORDANCE WITH THE PITKIN COUNTY REGULATIONS OF INDIVIDUAL SEWAGE DISPOSAL SYSTEMS, EVEN THOUGH ALL SUCH REWIREMENTS ARE NOT SPECIFICALLY NOTED ON THE DRAWINGS THE CONTRACTOR SHALL BE RESPONSIBLE FOR SUCH SPECIFIC DETAILS AS ARE REFERRED TO IN THE ABOVE MENTIONED REGULATIONS. 2. FLOW FOR BED: 4 BEDROOMS • 2 PERSONS/BEDROOM • 100 GALLONS/PERSON/DAY IS: 800GPD - AVERAGE DAILY FLOW. DESIGN FLOW - 1.75 • AVERAGE - 1400 GPD (0) SEPTIC TANK: M INIMUA TOTAL TANK SIZE: 0 . 1 DAY/24 HRS • 30 HRS - 1750 GPD INSTALL ONE 1750 -GALLON TANK WITH BAFFLE •..I INSTALL EFFLUENT FILTER IN SEPTIC TANK WTLET... STANDARD ABSORPTION AREA: A - 9—ft Q� IMUM FLOW t -PERCOLATION RATE - 31 m1n./1 n. - 142g13-1- - 1559 SF USE OF STANDARD INFILTRATOR UNITS IN TRENCH CONFIGURATION: 50S REDUCTION - (1559 SF .0.50 O 15.5 SF/UNIT, 51 UNITS REWIRED IN A TRENCH CONFIGURA ION (FOUR 10 UNIT + ONE 11 UNIT). 3. CLEAN OUTS ARE REWIRED AT ALL BENDS AND AT LEAST EVERY 100 FEET ALONG THE LOUSE SEWER. J 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING ALL WATER TIGHT COMPONENTS, PRIOR TO THE ABSORPTION AREA, TO PREVENT INFILTRATION. 5. TOPSOIL COVER MAY BE VARIED (WITH 1 FOOT MINIMUM) TO ALLOW LANDSCAPING. 8. INSTALL RISERS AS NECESSARY TO BRING ALL ACCESS POINTS TO WITHIN ONE-HALF FOOT OF FINAL GRADE. 7. LOCATIONS OF ALL COMPONENTS MAY BE VARIED AS NECESSARY AS LONG AS ALL MINI" DISTANCES AND SLOPES MEET THOSE REQUIRED. 8. PROVIDE POSITIVE DRAINAGE OF SURFACE WATER AWAY FROM ABSORPTION FIELD AREA USING DRAINAGE SWALES AS NECESSARY. 9. SOILS AND PERCOLATION INFORMATION FROM INFORMATION PROVIDED BY H.P GEOTECH, INC., JOB NO. 102 274, DATED APRIL 29, 2002. 10. THISDRAWING DOES NOT CONSTITUTE AN ISDS PERMIT. PERMIT MUST BE OBTAINED FROM APPROPRIATE CITY OR COUNTY OFFICIALS. ENGINEER MUST OBSERVE CONSTRUCTED SYSTEM BEFORE BACKFILL AND PROVIDE REPORT TO COUNTY. 11. THIS SYSTEM IS SIZED FOR TYPICAL DOMESTIC WASTES ONLY. BACKWASH OR FLUSHING FLOWS FOR REVERSE OSMOSIS UNITS OR WATER SOFTENERS OR FILTERS SHOULD NOT BE INTRODUCED INTO THIS SYSTEM. 12. INSTALL BLUEBOARD INSULATION OVER SEWER PIPE WHEREVER DEPTH IS LESS THAN 5.0 FEET. 13. THE ENGINEER SHALL BE CONTACTED FOR SITE INSPECTION PRIOR TO BACKFILLING OF SYSTEM COMPONENTS. 14. DESIGN OF ABSORPTION TRENCHES BASED ON SOIL PROFILE INDICATING 2 -FEET TOPSOIL OVERLYING SILTY CLAYEY SANDY GRAVEL WITH COBBLES AND SMALL BOULDERS TO A PROFILE DEPTH OF 8 -FEET. 15. SITE PLAN INFORMATION FROM HIRED GUN SURVEYING AND OWNER. 1. ABSORPTION LATERALS SHALL NOT EXCEED 100 FEET IN LENGTH. 2. THE BOTTOM OF EACH ABSORPTION TRENCH SHALL BE LEVEL. 3. DRAINAGE SWALES ARE TO BE PROVIDED ABOVE AND AROUND TRENCHES, AS NECESSARY, TO PREVENT SURFACE RUNOFF FROM ENTERING ABSORPTION AREA. 4. TRENCH LATERALS SHALL FOLLOW CONTOURS. S. INSTALL INFILTRATOR IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. 8. TRENCH BOTTOM AND SIDEWALLS MUST BE RAKED TO REMOVE SOIL SMEARS INCURRED WRING EXCAVATION. 7. NO EXCAVATION OF ABSORPTION FIELD IS TO BE DONE DURING WET WEATHER AND USE OF RUBBER TIRE VEHICLES OVER ABSORPTION AREA IS PROHIBITED 8. BOULDERS EXISTING WITHIN THE TRENCH SHALL BE EXCAVATED AND BACKFILL SHALL CONSIST OF ONSITE SELECT OR PIT -RUN MATERIAL. 9. IN ALL TRENCH CONFIGURATIONS, SERIAL DISTRIBUTION SHALL BE USED INSTEAD OF EWILATERAL DISTRIBUTION TO INCREASE SETTLING TIME AND PROTECT THE BACTERIAL BIOIAAT. 0 z _z w8 [Z� QAO "' aZi� W $ W 2 LL cr 51 Z� o Zhu Vin M �giE PROJECT NO. 2021()39.00 SHEET 1 APR -29-2002 10:58 C£OTECH L L. ' C L{ ( - CZ P.02/04 April 29, 2002 Joe Zanin Construction Attn: Yoe Zanin Hepworth-Pawlak Geotechnical, Ina. 5020 Countv Road 154 Glenwood SpriMm Colorado 81601 Phone. 970-945.7958 Fax: 970-945-8454 hpgeoghpgeotech.com 210 Aspen Airport Business Center, Suite MM Aspen. Colorado 81611 Job No. 102 274 Subject: Percolation Testing, 5084 Snowmass Creek Road, Pitldn County, Colorado Dear Mr. Zanin: As requested by you, Hepworth - Pawlak Geotechnical, Inc., performed percolation testing at the subject site. The work was done in accordance with our agreement for Professional Services to Joe Zanin Construction, dated April 19, 2002. A Profile Pit and three percolation test holes were excavated on April 21, 2002 at the locations shown on Fig. 1. The subsoils exposed in the Profile Pit consisted of about 2 feet of topsoil overlying silty clayey sandy gravel with cobbles and small boulders to the bottom pit depth of 8 feet. No free water was observed in the pit and the soils were slightly moist to moist. Percolation test holes were hand dug in the bottom of shallow backhoe pits and soaked with water on April 21, 2002 by Joe Zanin Construction. Percolation testing was conducted on April 22, 2002, by a representative of Hepworth - Pawlak Geotechnical, Inc. The percolation test results are summarized on Table I. Based on the subsurface conditions encountered and the percolation test results, the tested area, should be suitable for a conventional infiltration septic disposal system. Pitkin County requires that a professional civil engineer design the septic disposal system. If you have any questions or need further assistance, please call our office. Sincerely, HEPW9RTH - PAWZ.AK GEOTECHNICAL, INC. Louis E. Filler Q D; Ll ar cc nc Walter APR -29-2002 10:56 GEOTECH NOT TO SCALE r»--------------------� I I I i I l 1 I I APPROXIMATE OUTUNE i - OF EXCAVATION FOR i PROPOSED RESIDENCE 5084 SNAOWMASS CREEK ROAD I I L - - -- -- -j i L i ---------------- PROFILE PIT Z' P. 0-7/04 102 2741 GERWO NICALW C_ LOCATION OF PERCOLATION PEST HOLES 1 Fig. 1 APR -29-2002 10:58 ) GEOTECH x.04104 HEPWORTH-PAWLAK GEOTECHNICAL, INC. TABLE 1 PERCOLATION TEST RESULTS JOB NO. 102 274 HOLE NO. HOLE DEPTH (INCHES) LENGTH OF INTERVAL (MIN) WATER DEPTH AT START OF INTERVAL (INCHES) WATER DEPTH AT END OF INTERVAL (INCHES) DROP IN WATER LEVEL (INCHES) AVERAGE PERCOLATION RATE (MINANCH) P-1 .38 15 water added 8 6 314 1 1/4 ' 36 6 314 6 114 112 73/4 7 314 7 6 1/2 112 6 1/2 6 114 114 61/4 5 3i4 112 P-2 40 15 water added 8 6 2 i 30 6 5 114 314 7 6 114 34 6 114 5 3;4 112 5 314 5 114 112 5 1/4 4314 1/2 P-3 44 15 water added a 6 314 1 1/4 I ,# f 26 63/4 6 314 8 7 114 314 71/4 6 1/2 314 61/2 6 112 6 5 1/2 112 Note: Percolation test holes were hand dug in the bottom of backhoe pits and soaked on April 21, 2002. Percolation tests were conducted on April 22, 2002. The average percolation rate is based on the last three readings of each test. TOTAL P.04 WELL CONSTRUCTION ASP TEST REPORT —)R OFFICE USE ONLY STATE OF COLORADO, OFFICE OF THE STATE ENGINEER L WELL PERMIT NUMBER 232508 Owner Name(s): Brad Zanine 2 Mailing Address: 765 Cementary Lane City, State, Zip: Aspen, Co. 81611 Phone # 970-544-0245 APPROVAL # GWS31-91-03 3 WELL LOCATION AS DRILLED SW 1/4 NE 1/4 Sec: 14 Twp: 9 S Range: 86 W DISTANCES FROM SEC. LINES 1980 ft. from North Sec. line and 1350 ft. from East Sec. line OR Northing: Easting: SUBDIVISION: Snowmass Trust LOT: B BLOCK: FILING (UNIT): STREET ADDRESS AT LOCATION GROUND SURFACE ELEVATION ft. DRILLING METHOD Air Rotary 4 DATE COMPLETED: 4/18/2002 TOTAL DEPTH: 82 DEPTH COMPLETION: 82 5., GEOLOGIC LOG 6. HOLE DIAMETER (in) FROM (ft) TO (ft) Depth Type of Material Size, Color, and Type) 9.0 0 53 000-007 Topsoil 6.5 53 83 007-083 Boulders, Sand, Gravels 7. PLAIN CASING OD (in) Kind Wall Size From (ft) To (ft) 7.0 Steel 0.240 -1 35 5.5 PERF. CASING : Screen Slot Size 7.0 Steel 0.240 35 53 5.5 Steel 0.188 35 83 8. Filter Pack 9. Packer Placement Water Located: 35 + Material Type Size : Depth Remarks Interval 10. GROUTING RECORD Material Amount Density Interval Placement Cement 4 sks 6 al/sk 10-25 poured 11. DISINFECTION Type HTH Amt. Used: 2 oz. 12. WELL TEST DATA : () Check Box If Test Data Is Submitted On Supplemental TESTING METHOD: Air. Compressor Static Level : 26 ft. DatelTime Measured 4/18/2002 Production Rate 15 gpm Pumping Level : Total ft. Date/Time Measured 4/18/2002 Test Length : 2 hours Test Remarks : 13. I have read the. statements made herein and know the contents thereof, and that they are true to my knowledge. (Pursuant to Section 24-0-1-4 (13)(a) CRS, the making of false statements to the second degme and is punishable as a class 1 misdemeanor.) constitutes pegtuy CONTRACTOR : Shelton Drilling Corp. Phone: (970) 927-4182 Mailing Address : P.O. Box 1059 Basalt, Co. 81621 Lic. No. 1095 Name / Title (Please Type or :Print) Signature Date 4/19/2002 Wayne Shelton / President wA!%\o W_ ■ 2 ■ 3 • ■ ■ 0 ■ r W a ADMINISTRATIVE DECISION OF THE COMMUNITY DEVELOPMENT DIRECTOR OF PITKIN COUNTY, COLORADO, APPROVING THE ZANIN SUBDIVISION EXEMPTION FOR A MINOR PLAT AMENDMENT Administrative Decision No. L-2002 RECITALS 1. Brad Zanin ("Applicant") has applied to the Community Development Director of Pitkin County ("Director") pursuant to Section 3-190-080 of the Pitkin County Land Use Code ("Code"), for a subdivision exemption fora minor plat amendment to designate an accessory building envelope to accommodate a barn. 2. The property is located at 5084 Snowmass Creek Road, and is described as Parcel B, Snowmass Trust Subdivision. The lot is zoned RS-30/PUD and contains 8.207 acres. 4. The Director finds that the request is consistent with the requirements of the Land Use Code. APPROVED by the Director, subject to the following conditions: I . The Applicant shall prepare an amended plat in accordance with Section 5-40 of the Land Use Code, which shall designate the accessory building envelope. The plat shall be titled "First Amended Plat of Parcel B, Snowmass Trust Subdivision." The plat shall also be submitted in digital format suitable for integration into the County's GIS system. 2. The barn shall be limited to 1,800 square feet. The Applicant shall comply with the County's lighting regulations. 4. Dogs shall be kenneled. 5. No development, including grading, excavation, fill placement, berming, landscaping, well, septic system and vegetation removal or disturbance shall occur outside of the approved building and accessory building envelopes. The Applicant shall adhere to all material representations made in the application. APPROVED by the Director, this Ab -day of ^v? lam, 2002. Cin y Houben., Community Development Director P197-01 PID #26451410[002 466405 Page: 1 of 1 04/19/2002 03:18F SILVIA DAVIS PITKIN COUNTY CO R 0.00 D 0.00 FROM : SCOTTIES LAYOUT BY DESIL FAX NO. : 970 927 3641 Apr. 25 2002 04:37PM P1 N 11^04 00 E 432 PO N Oo D zD—I (:X! Si 1 NG COUNTY ROAD ti T � _ O . .. Oro NORTH m� m— ------ ~f a--135.00' ---- -� a ' ::;CC) 5 00' ' 1vX� O •� W N _ N 1 F oz — Z' N -azo CD FT -1 CO m 92.00' W o _ N + q8 -i N nx t O + i- - TI O + m �'• N W � O D + -} + -� acN ^' O pox Z - ++ 0 0 0150.00' ---- o - F — -- 132.00' f O � Z C 1 m m Z 05.S4.14•w 335."_- 52 -2- fro4V4 �,V 060 A A6 CAW-�el 1qf 0 13 RECEIVE[) . . . ... ....... PITKIN COUNTY - -------------- I I ?w] ftd�,335.5:2 G k, w 0 0 00 M 05 .521.oli 1 08 U) 0 T �kl ct /Ijtrofr�p i li -L j.00'l 7'15 #W/ Z (14 f 11 �(� �o _, 'Inn i - (A IS) *41 C -P m Ads*, wow ks* ftd�,335.5:2 G k, w 0 0 00 M 05 .521.oli 1 08 U) 0 T �kl ct /Ijtrofr�p i li -L j.00'l 7'15 #W/ Z (14 f 11 �(� �o _, 'Inn i - (A IS) / � I r elle y Davis/Dof B �N .N: IMP 216'45 ............ • 1 4. I 1'r , • ,'00011 � � `. - � ^� � i f, 1 1000 1 ' uwnl 1 , Woos � ' loloof ir: '..ter .�.� , ._... j1 .' �\�..... __.. ..... ...�. —... ' I I I m, � s tm -rrIYEL a ' I I� wmass �I �I I ' V90 rf REMOVABLE CAP NATURAL BACKFILL 4" 0 CUT HOLE IN TOP OF 12" MIN. COVER SOLID PIPE INFILTRATOR JNIT FOR 36" MAX. COVER \/ INSTALLATION OF INSPECTION �\ / OUWELL PIPE CI9 RL GGHEN ED 12" /\\ O \ 4" 0 PERFORATED PIPE NTRENCH BOTTOM LEVEL NATURAL GROUND AND ROUGHENED 36" 36" INSPECTION WELL DETAIL N, T. S. > SE N. T. S. 12" INFILTRATOR UNIT REMOVABLE PVC CAP INSTALL MARKER IF CAP IS TO BE BURIED FINISH 4" COUI 4" SEWER I 4" PVC 3END —CLEAN OUT ASSEMBLY SEWER CLEAN OUT DETAIL N.T.S. RE 0 C a' VICINITY MAP SCALE: 1"=2000' " N010 1. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE PITKIN COUNTY REGULATIONS OF INDIVIDUAL SEWAGE DISPOSAL SYSTEMS, EVEN THOUGH ALL SUCH REQUIREMENTS ARE NOT SPECIFICALLY NOTED ON THE DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SUCH SPECIFIC DETAILS AS ARE REFERRED TO IN THE ABOVE MENTIONED REGULATIONS. 2. FLOW FOR BED: 4 BEDROOMS * 2 PERSONS/BEDROOM *ICO GALLONS/PERSON/DAY IS: 800 GPD = AVERAGE DAILY FLOW. DESIGN FLOW = 1.75 * AVERAGE = 1400 GPD (0) SEPTIC TANK: MINIMUM TOTAL TANK SIZE: Q a 1 DAY/24 HRS * 30 HRS = 1750 GPD INSTALL ONE 1750–GALLON TANK WITH BAFFLE * *INSTALL EFFLUENT FILTER IN SEPTIC TANK OUTLET*** STANDAR, ON AREA: A = Q Ft Q=MAXIMUM FLOW —S t=PERCOLATION RATE = 31 min./in. 1400,F31 = 1559 SF 5 USE OF STANDARD INFILTRATOR UNITS IN TRENCH CONFIGURATION:, 50% REDUCTION – (1559 SF *0.50) @15.5 SF/UNIT, 51 UNITS„! REQUIRED IN A TRENCH CONFIGURATION (FOUR 10 UNIT + ONE 11 UNIT). 3, CLEAN OUTS ARE REQUIRED AT ALL BENDS AND AT LEAST EVERY 100 FEET ALONG THE HOUSE SEWER. 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING ALL WATER TIGHT COMPONENTS, PRIOR TO THE ABSORPTION AREA, TO PREVENT INFILTRATION. 5. TOPSOIL COVER MAY BE VARIED (WITH 1 FOOT MINIMUM) TO ALLOW LANDSCAPING. 6. INSTALL RISERS AS NECESSARY TO BRING ALL ACCESS POINTS TO WITHIN ONE–HALF FOOT OF FINAL GRADE. 7. LOCATIONS OF ALL COMPONENTS MAY BE VARIED AS NECESSARY AS LONG AS ALL MINIMUM DISTANCES AND SLOPES MEET THOSE REQUIRED. C.'r:= -IDAINArF 0" cIJPr ACE WATER AWAY FROM ABSORPTION F!ELD AREA USING Di<A, N,,GE vN, �- AS .,ECES: 9. SOILS AND PERCOLATION INFORMATION FROM INFORMATION PROVIDED BY H.P GEOTECH, INC., JOB NO. 102 274, DATED APRIL 29, 2002. 10. THIS DRAWING DOES NOT CONSTITUTE AN ISDS PERMIT. PERMIT MUST BE OBTAINED FROM APPROPRIATE CITY OR COUNTY OFFICIALS. ENGINEER MUST OBSERVE CONSTRUCTED SYSTEM BEFORE BACKFILL AND PROVIDE REPORT TO COUNTY. 11, THIS SYSTEM IS SIZED FOR TYPICAL DOMESTIC WASTES ONLY. BACKWASH OR FLUSHING FLOWS FOR REVERSE OSMOSIS UNITS OR WATER SOFTENERS OR FILTERS SHOULD NOT BE INTRODUCED INTO THIS SYSTEM. 12. INSTALL BLUEBOARD INSULATION OVER SEWER PIPE WHEREVER DEPTH IS LESS THAN 5.0 FEET. 13. THE ENGINEER SHALL BE CONTACTED FOR SITE INSPECTION PRIOR TO BACKFILLING OF SYSTEM COMPONENTS. 14. DESIGN OF ABSORPTION TRENCHES BASED ON SOIL PROFILE INDICATING 2–FEET TOPSOIL OVERLYING SILTY CLAYEY SANDY GRAVEL WITH COBBLES AND SMALL BOULDERS TO A PROFILE DEPTH OF 8–FEET. 15. SITE PLAN INFORMATION FROM HIRED GUN SURVEYING AND OWNER. GENERAL ABSOMM TFEPM NOW 1. ABSORPTION LATERALS SHALL NOT EXCEED 100 FEET IN LENGTH. 2. THE BOTTOM OF EACH ABSORPTION TRENCH SHALL BE LEVEL. 3. DRAINAGE SWALES ARE TO BE PROVIDED ABOVE AND AROUND TRENCHES, AS NECESSARY, TO PREVENT SURFACE RUNOFF FROM ENTERING ABSORPTION AREA. 4. TRENCH LATERALS SHALL FOLLOW CONTOURS. 5. INSTALL INFILTRATOR IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS. 6. TRENCH BOTTOM AND SIDEWALLS MUST BE RAKED TO REMOVE SOIL SMEARS INCURRED DURING EXCAVATION. 7. NO EXCAVATION OF ABSORPTION FIELD IS TO BE DONE DURING WET WEATHER AND USE OF RUBBER TIRE VEHICLES OVER ABSORPTION AREA 15 PROHIBITED 8. BOULDERS EXISTING WITHIN THE TRENCH SHALL BE EXCAVATED AND BACKFILL SHALL CONSIST OF ONSITE SELECT OR PIT–RUN MATERIAL. 9. IN ALL TRENCH CONFIGURATIONS, SERIAL DISTRIBUTION SHALL BE USED INSTEAD OF EQUILATERAL DISTRIBUTION TO INCREASE SETTLING TIME AND PROTECT THE BACTERIAL BIO–MAT, z 0 LJ Df M W } 0 n Q a Y Cn Z 0 U ( N U Q N � Z Q 0 O CD 0 W fA J d O Q L 5 Z PROJECT N0. 2021039.00 SHEET 1