HomeMy WebLinkAboutpitkin.eh.264514300002 (2004) Main HousePermit # 04060 Pitkin County Environmental Health Department Per for an Individual Sewage Disposal S am 0405 Uastle Creek Road, Suite 10, Aspen, Colorado - i X311 Phone 970-920-5070 / FAX 970-920-5077 00 - 00_ Parcel ID # 2645-143 Type of permit New(x ) Repair( ) Addition/Remodel to House( ) Name of Owner Jan and Art Martin Street Address 5721 E. Snowmass Creek Rd Property legal description Parcel B Schubert Subdivision Exemption Size of lot 40.10 acres Water source Private Well (existing) # of bedrooms in house 4 Caretaker unit # of bedrooms in caretaker unit Designed for what # rooms ;list) Designed by Total square footage of the house 5,572 # of offices, lofts & similar sized rooms in house Total square footage of the caretaker unit # of offices, lofts & similar sized rooms in caretaker unit 4 bedrooms 1 ChurcC,i & Associates Permit information Mailing Address 4501 Wadsworth Blvd, Wheat Ridge, CO 80033 Perc rate 42 mpi Profile hole depth 8 ft Depth to groundwater or bedrock Greater than 8 ft. Minimum Septic tank capacity 1750 gallons Minimum Absorption area 907 sq ft w/ 50% reduction Comments Septic permit approved per compliance with the engineer design and specifications dated August 12, 2004. Any changes must be approved by this department and the design engineer prior to them being made. Minimum horizontal distances between components of the system and physical features shall conform to the Pitkin County ISDS regulations. There must be a 132 foot separation between the well and the field. There should be 10 feet between any lined water feature and the field. Any unlined pond or ditch must maintain a setback of at least 82 feet. This design will consist of one 2000 gallon two compartment tank with an effluent filter on the outlet. A flow splitter basin will be used to distribute effluent to 5 trenches, each trench having 12 chambers for a total of 60 chambers. Each trench should be separated by at least 6 feet of undisturbed soil. This department does not endorse any brand of products. This permit must be kept on-site during installation. The engineer must do a final inspection of the installation and submit an as -built letter to this department. This department must also be called for an inspection with a minimum of 48 hours advanced notice. *Revegetation over the area of the field is very important for the functioning of the system. Pitkin County has guidelines that must be followed to assure the plants that are introduced are appropriate for the conditions of the area. The use of native plants is strongly �' r U 1,�� Permit approved by: � �,� Date:_4 O Plans and specifications of the proposed individual sewage disposal system have been reviewed and are considered satisfactory. Permission is hereby granted to the owner or the agent to perform the work indicated in accordance with the Pitkin County ISDS Regulation in effect at the time of issue. This permit becomes invalid 6 months from the date that the permit was issued unless system construction has commenced or an extension has been approved in writing by the Department. As -built drawings must be included with this permit before the final approval will be issued. Installer: Final approval: Date: Date: C? d PITKIN COUNTY ENVIRONMENTAL HEALTH & NATURAL RESOURCES DATE: 10/27/05 Send to: Ken Smith Fax Number: 927-4635 CC: Church OWC, LLC CC Fax Number: ❑ URGENT ❑ REPLY ASAP COMMENTS: From: Alicia Gomez Phone Number: 920-5087 Number of Pages, Including Cover: 2 ❑ PLEASE COMMENT ❑ PLEASE REVIEW 21 FOR YOUR INFORMATION Septic Permit # 04060 for parcel 2645-143-03-001, owner Martin, has been finalized. Please feel free to call 920-5070 if you have any questions. fax' cover Pitkin County Environmental Health and Natural Resources 0405 Castle Creek Road Suite #10, Aspen, CO 81611 Phone(970)920.5070 1 Fax(970)920.5077 Web site www.,aspenpitkin.com/depts/12/ 07/'13/2004 11:32 970927.16'' KCSMITHBUILER .Jul 1 04 11:39a /tkin Ce Env. Health (S 9-!-5077 PITKIN COUNTY EhMRONMENTAL HEALTH DEPARTMENT APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM 0405 Castle Creek Road, Suits 10, Aspen Colorado 81611 Phone (970) 920.5070 Fax (970) 920-5077 Name of OWNER Owner's Mailing Address 1€0i -4 Li- . cbrotQ- "71 3. 5" • C 'l 31 primary COr>tact Person (all communication KP.r, a,MiA L. €n�ress 6 ZIP �rbnrwwSs , (o I toS q- q�: ao8 �_ Fax; X27 435 Gi};(;ofr} e, 0n01.cb1n this permit Wlli 90 through this person) F1 Parcei ID # (Avaitabis born asaeseor•s ofte at 920-5160 or at W0vw.PItkina9s"sorora) street address of property S� 21 E , i, -b, rnasi Gree tL Q� legs€ DGWAption: Lot _ Block _ ,FIIM Subdivision „ 1arc"\ Sbu1%er� Su�',u� Size cf Pot: lc)� $ Type of proposed structure: ScdK,n ' t� 1kvrJ Total s ivare feet of house _ 5,512 # of bedroom!; (potential) In house 4 Caretalmr Univ Auted ( ) Detached ( ) WA Total areasso. IQ of caretaker unit # of bedrooms (potential) in Caretaker unit Permit €s for. New t-� Repair due to failure ( } Remodel/Addition ( ) Ernergmxj use ( ) Water. Private weft ,:X ) Spring ( ) Stream ( } Commuri ty/Public Water System ( ) If community system: Nerve of svetem PAGE 05/09 The fee for a ISDS application is $6M for a permit that takes 6 hours or less for the department to approve. If approval takes longer than 8 hours, r: rete of $100 per hour wAl be Chortled, The mwdmum fee is $1000. The basic The of $6M is due at the time of sppOgtlon. Tha remainder, if any, viii be due In two stn": first, at the time of issuance or the ISBS permit; second, before final approval 3f the ISDS pern>it. Appllnatinn for an Individual sewage dispo&al system Is hereby submitted, I hereby {artily that the above information is true and accurate 80d that I have provided true and acaumte information on locations of all e)63tfrrg and proposed wells, contour intervals buildings property lines, ditches, slopes, waterlines, springs, suction or Irrigation iiM, drinking water cisterns, dmin files, iMpaion ditehas lakes, water courses, streams, floodplains, dry guk has, and existing septi; systems. I hereby cartIfy #het tory such features not shown on attached site map are not present. Issuance of the permit does not Imply the approval of any other permit requdred forconstrudlon pursuant to Pitkin County codes. No construction may be undertaken untfl ail approvals and permb have been obtained. The Pitki - County Emrironmenta! Health Department, Pitkin County and employees of areae egencies will be heli harmless should the Indvidua€ ;reftge disposal system fall or malfunction. The permit to construct is issued on information submitted by the applicant or h€sfnt!r representatives. The owner assumes full responsMity In case of fallure of the system. Signature of appli;ant — bate Received by Receipt IC g 7 Date 7 G:Wdslisds applI69dSMT R0v050103.doc p.3 exern0zNA CHURCH & Associates, Inc. ENGINEERS & GEOLOGISTS December 13, 2004 Jan & Art Martin C/O Hagman Architects, Attn: Tony Major 0123 Emma Road, Suite 200 Basalt, Colorado 81621 Subject: Installation Observation, Proposed Residence 5721 Snowmass Creek Road Pitkin County, Colorado Job No. 16526 Mr. Major, RECEIVED DEC 15 2004 PITKIN GOLINTY ENVIRONMENTAL HEAL' As requested, we observed the installation of the onsite wastewater system for the subject site on December 11, 2004. The system was designed under our Job No. 16526, last revised August 12, 2004. The system includes the installation of a 2000 -gallon, two-compartment, concrete septic tank with an effluent filter on the outlet, and seven gravelless chamber -trenches. One trench has one row of 11 Infiltra- tor® Quick4TM chambers, two trenches have one row of 12 chambers each, one trench has one row of 13 chambers, one trench has one row of 14 chambers, one trench has one row of 15 chambers, and one trench has one row of 16 chambers, for a total of 93 chambers and 911.4 ft' of infiltrative area. An as -built drawing is included as Figure 1. The easternmost 3 trenches were deeper than desired, but are suitable with the belief that any revision would not improve the situation. The observed components of the OWS were installed in general conformance with our design. Our installation observations do not imply a guarantee or warranty of materials or workmanship. Sincerely, CHURCH & Associates, Inc. �p0 REGiS 22 Reviewed by EiL�� 2 J o oP c� h E ward O. Curch Eric R. Burns ' Field Technician SS ALU EOC/erb 2 copies sent Copy to PCEHD, Attn: Nancy MacKenzie Copy to KC Smith Builders, Attn: Ken Smith, 6801 E. Sopris Creek Rd., Snowmass, CO 81654 Copy to Earthworks Construction, 0304 Highway 133, Carbondale, CO 81623 DENVER 4501 Wadsworth Boulevard Wheat Ridge, CO 80033 www.geo-church.com 303:463.9317 Fax: 303.463.9321 Toll Free -1.877.248.3123 4y� Y��o,i 4#�yiii ,`4'Y", g� ,mac :i'',._ # �► '*V . ` .� /w �3�i ��• 14`4'" � � •� ,� * � 4+�� ., •e a► jt i f K r ♦ �Y �Ac ' .� ^ / SCALE 5721 SmOvmv»ASS CREEK ROAD � PITKIN COUNTY, COLORADO CID SETBACK |0N/ ENTP\PES(TYP.) LINED \ \ POND � \, / ``. 911.4 SF OF INFILTRATIVE AREA IN SEVEN |NF!LTR4T0R(R)&U|CK4(TM)GRAVELLESS ` . CHAMBER -TRENCHES. NUMBERS REPRESENT � THE NUMBER OFCHAMBERS TOBE INSTALLED \ ` IN EACH TRENCH FOR 4TOTAL OF 95 CHAMBERS.-----.,_ CONCRETE DISTRIBUTION BOX WITH FLOW LEVELERS TO EQUALIZE FLOW TO EACH TRENCH. ACCESS VIA\ ` 4CONCRETE RISER WITH MANHOLE. `cp 4"EFFLUENT LINE— PROPOSED RESIDENCE \ ' \ | , / ` / ./' ' � ^ . ` \PROPOSED DRIVEWAY GARAGE—~� -rn \ ^^' jOB NO. 16526 �3 ~� ~.4o \ \`� ' �-2U00-6ALLON,TWO-COMPARTMENT,CONCRETE SEPTIC TANK WITH ANEFFLUENT FILTER ON THEOUTLET ~m� 4" SEWER LINE \ N8|HCLE4NOUT Specia • • 1 • Innovative Distribution of Quality Cedar and Redwood Products Dan Dellavechio Cell: 303-588-5566 2203 Uravan Street • Aurora, Colorado 80011 303-288-8484 • FAX 303-288-5650. 1-800-760-8484 dand@specialtywoodproducts.net www.specialtywoodproducts.net Project: Date: Eric Burns, 02:49 PM 12/21/200 RE: Martin 5721 E. Snowmass Creek Road Page 1 of 1 Subject: RE: Martin 5721 E. Snowmass Creek Road Date: Tue, 21 Dec 2004 14:49:18 -0700 Thread -Topic: Martin 5721 E. Snowmass Creek Road Thread -Index: AcTnnsppsMgJFnE/SfWxszFc+rv5QgAENpBg From: "Eric Burns" <ebums@geo-church.com> To: "Nancy MacKenzie" <nancym@ci.aspen.co.us> X -Spam: exempt X -MAIL -FROM: <ebums@geo-church.com> X -SOURCE -IP: [64.25.14.238] X-MailScanner-Information: Please contact the ISP for more information X-MailScanner: Found to be clean X-MIME-Autoconverted: from quoted -printable to 8bit by commons.ci.aspen.co.us id OAA11368 It's not lined yet. Sean with Earthworks said they were planning on doing it in the spring. -----Original Message ----- From: Nancy MacKenzie [mailto:nancym@ci.aspen.co.us] Sent: Tuesday, December 21, 2004 12:51 PM To: Eric Burns Subject: Martin 5721 E. Snowmass Creek.Road Hi Eric, Got the as -built for this one. I can't final it because the field is close to a pond. The pond is supposed to be lined, but it sure didn't look lined to me. What did you notice? Happy Holidays, Nancy Nancy MacKenzie Pitkin County Environmental Health Senior Environmental Health Specialist 0405 Castle Ck Rd, Suite 10 Aspen, CO 81611 970-920-5076 970-920-5077 fax nancym@ci.aspen.co.us Printed for Nancy MacKenzie <nancym@co.pitkin.co.us> 12/21/2004 phone 970-920-5438 fax 970-920-5077 0405 Castle Creek Rd, Aspen CO 81611 e-mail carlab@ci.aspen.co.us IMdo To: Building Department From: Carla Block Fax: 920-54:39 Pages: 2 Phone: Date: 9/13/04 Re: septic permit CC: ❑ Urgent GAJ For Review ❑ Please Comment ❑ Please Reply ❑ Please Recycle This is for Martin, 5721 Snowmass Creek Road. If you have any questions regarding this permit, please give me a call. Thank you, Carla phone 970-920-5438 fax 970-920-5077 0405 Castle Creek Rd, Aspen CO 81611 e-mail carlab@ci.aspen.co.us To: Ken Smith From: Carla Block Fax: 927-4635 Pages: 2 Phone: Date: 9/13/04 Re: septic permit CC: Church and Associates ❑ Urgent 121 For Review ❑ Please Comment ❑ Please Reply ❑ Please Recycle If you have any questions regarding this permit, please give me a call. Thank you, Carla J ToS � I a i Lot Martin Residence 5721 Snowmass Creek Road Pitkin County, Colorado o,z �0 • D oob b� Martin Residence 5721 Snowmass Creek Road Pitkin County, Colorado o,z �0 • I� ' Martin Residence 5721 Snowmass Creek Road Pitkin County, Colorado A o = = >G) ; 6 b N a o 0 7 I 78 Martin Residence 5721 Snowmass Creek Road Pitkin County, Colorado FAN • ^ Engineer's Submittal for Septic Permit in Pitkin County SEP 1 U 2004 PITKIN COUNTY ENVIRONMENTAL HEALTH Owner's Last Name: MARTIN Location: 5721 SNOWMASS CREEK ROAD Summary of information regarding new septic system: Type of system being proposed: GRAVELLESS CHAMBER -TRENCHES Other treatment processes being used: EFFLUENT FILTER Does the system use any mechanical parts? (Prohibited unless there is no alternative) NO If yes, explain why there are no alternatives Does the system require any maintenance other than routine pumping? YES If yes, who will do the maintenance? CLEAN FILTER WHEN SEPTIC TANK IS PUMPED Are any reductions being proposed? YES If yes, what makes the lot and soil conditions optimal? GOOD PERCOLATION RATES AND PROPOSING TRENCHES Which of the following are on the site or within setbacks? Closest distance of septic system to each feature [j 100 year floodplain N/ [XI well(s) 132 FEET [j irrigation ditches N/A [X] streams 82 FEET [X] ponds 82 FEET [] other What was the profile hole depth? 8 FEET What is the depth to groundwater? N/A What is the depth to bedrock? N/A What assumptions, if any, were made in system sizing and design? (Include any local, site- specific data, such as months without snow cover, ratio of evaporation to absorption, etc. that are relevant.) If there are any variations from normal design, please explain how they can be demonstrated to improve treatment and protect water quality. NONE A ASPEN/PITKIN ENVIRONMENTAL HEALTH DEPARTMENT ISDS DESIGN CALCULATIONS Owner's Name Parcel ID # House Size (sq. ft.) (75 gpd, 100 gpd, or 130 gpd) Number of Bedrooms in Main House Number of Offices, Libraries, Studies, Similar -sized Rooms in Main House Number of Bedrooms in Detached Caretaker unit Number of Offices, Studies, Similar -sized Rooms in Caretaker Unit (If the caretaker unit is ATTACHED, treat as if part of main house.) Average Daily Waste Flow 800 State Review Required? no Perc Rate Design Flow (Q) = # potential bedrooms X 2 people/bedroom X gpd X 1.75 Q= 1400 Absorptior Area (A= Q X SQRT T/5) A = 1815 sq. ft. of absorption area required 117 infiltrator units without reduction A maximum 50% reduction is allowed for use of deep gravel or gravelless chambered system, only if the lot size and soil conditions are optimal. If a reduction is being proposed, describe why lot size and soil conditions are optimal: 50% REDUTION TAKEN FOR GOOD PERCOLATION RATES AND USE OF GRAVELLESS CHAMBERS A = 907 sq.ft. with reduction 59 infiltrator units with reduction Type of system: []Absorption trenches []Absorption bed [X] Gravelless chambers []Dry well []Seepage Pit []Other Minimum tank capacity 1750 gallons SETBACK FROM WELL # of feet = SETBACK FROM POND, STREAM OR IRRIGATION DITCH # of feet = 82 SETBACK FROM DRY GULCH # of feet = 57 FINAL INSPECTION BY: DATE: 100 CHURCH Associates, ENGINEERS & GEOLOGISTS k F� I•:! :j Jan & Art Martin C/O Hagman Architects, Attn: Tony Major 0123 Emma Road, Suite 200 Basalt, Colorado 81621 Subject: Revised OWS Design, Proposed Martin Residence 5721 Snowmass Creek Road Pitkin County, Colorado Job No. 16526 Mr. & Mrs. Martin, As requested, a revised onsite wastewater system (OWS) design has been prepared for the proposed residence. The revisions are based on a more accurate site plan provided by Hagman Architects, Inc. Our previous design date avoid confusion. Hepworth-Pawlak Geo- technical, Inc. (HP Geotech) performed the subsurface investigation on June 8, 2004. SITE CONDITIONS The property is in a rural residential area of Pitkin County, where OWS are required. The proposed drain field area slopes approximately 16% to the northeast. The drain field area has moderate cover of native grasses and weeds with scattered scrub oak. Water is supplied to the site by a well located greater than 132 feet from the proposed drain field area. PROPOSED CONSTRUCTION A Il g a► a proposed at the location presented on Figure 1. The OWS was sized based on 4 bedrooms and 800 gallons per day (GPD) using Pitkin County Environ- mental Health Department (PCEFID) loading of 100 gallons per day per person. The sewage loading with a peaking factor of 1.75 is 1400 GPD. This loading includes washing machines and garbage grinders. If additional bedrooms in unfinished areas are possible, it is suggested the OWS be constructed to handle the additional loading. The installation of an engineered OWS to serve future build -out can be cost effective. SUBSURFACE CONDITIONS HP Geotech performed the subsurface investigation by digging three percolation holes, 42 to 64 inches deep, and one profile pit at the locations indicated on Figure 1. Subsurface materials reported in the profile pit consisted of 2 feet of silty, sandy, gravel topsoil, underlain by silty, sandy clay to 4 feet, underlain by clayey, sandy gravel with cobbles to the maximum depth explored of 8 feet. 4 Percolation tests indicate percolation rates ranging from 20 to 60 minutes per inch (MPI). The average percolation rate ='rcolation data is included as Appendix A. RECOMMENDATIONS The design requires a septic tank with an effluent filter and a gravelless chamber -trench drain field at the locations presented on Figure 1. The OWS design is based on an average sewage load of 800 GPD DENVER 4501 Wadsworth Boulevard Wheat Ridge, CO 80033 www.geo-church.com 303.463.9317 Fax: 303.463.9321 Toll Free -1.877.248.3123 l Revised OWS Design Job No. 16526, 8/12/04 Page 2 and a percolation rate of 42 MPI. The installation must include on The drain field must have MWA]Wro'A flow splitter basin, or equivalent, is required to distribute effluent to the trenches. Vehicle movement over the drain field area during construction should be kept at a minimum to minimize compaction of the receiving soils. The bottom of the trenches should be scarified with a pick, shovel, or backhoe bucket teeth prior to the addition of chambers. The surface of the field should be seeded after installation of the fields. A native seed mix should be sown at the drain field to revegetate the surface. These mixes do not require irrigation and develop a growth 10 to 15 inches high. No automatic sprinkler system should be installed over the trenches. OPERATION AND MAINTENANCE The owner must realize an OWS is different from public sewer service. The owner must be aware of and assume responsibility for maintenance of the system. In the absence of a monitoring program, the septic tank should be pumped every two years. Effluent filter and screened vaults, as applicable, are to be cleaned during pumping. There are daily considerations such as not putting plastic or other nonbio- degradable materials into the septic system. Garbage disposal use should be minimized. The backwash of a water softener may be harmful to the OWS. A separate drywell should be constructed for the backwash waste, if a softener is installed. Chemically treated water from a swimming pool or spas should not be introduced to the OWS. LIlVMATIONS A contractor who is experienced in OWS installation should be hired for the construction. Our investiga- tion, layout, design and recommendations are based on data submitted. If subsurface conditions different from those described in this report are encountered, we should be notified to evaluate the proposed OWS. If the health department modifies this design, we should be contacted to evaluate the impact on the perfor- mance of the OWS. The county and our firm must be contacted upon completion of the OWS All construction is to be in accordance with the ISDS regulations. Pipe type and size, burial requirements, septic tank construction, and other specifications, which are not depicted in our report, are to conform to the requirements of the ISDS regulations. The installer of the system is to have demonstrated knowledge of the PCEHD ISDS regulations and requirements. If there are questions, please call. The project engineer for this site is Eric Burns. CHURCH & Associates, Inc. Eric R. Burns Design Technician EOC/erb 3 copies sent via FedEx Re Ed 5721 SNOWMASS CREEK ROAD PITKIN COUNTY, COLORADO EXISTING DRIVE'! ,y / i .-A /,-/, -APPROX LOCATION OF EXISTING WELL SCALE ill = 100' PARTIAL SITE PLAN AND LOCATION OF 8/12/04 JOB NO. 16526 PERCOLATION HOLES REVISED FIGURE 1 D ; 5721 SNOWMASS CREEK ROAD SCALE ,. PITKIN COUNTY, COLORADO 1" = 20' c ' ' W 10' SETBACK ` / ) OBSERVATION/ / I I VENT PIPES (TYP.) r" LINED . / POND o 930 SF OF INFILTRATIVE AREA IN FIVE GRAVELLESS'\;CHAMBER=TRENCHES. EACH TRENCH MUST HAVE ONE ROW OF 12 CHAMBERS FOR AJOTAL OF 60 CHAMBERS. O l • FLOW SPLITTER BASIN (OR EQUIVALENT) O I 4" EFFLUENT LINE > W I 1 � r I cp I 2000 -GALLON, TWO-COMPARTMENT, CONCRETE SEPTIC TANK�H AN EFFLUIENT FILTER ON THE OUTLET i 4" SEW R LINE WJH CLEANOUT PROPOSED 4 -BEDROOM RESIDENCE i i . 7 I i e. ,PROPOSED I " > DRIVEWAY ` - -GARAGE JOB NO. 16526 LOCATION OF PROPOSED OWS / I I i i I I I I I I I I I I I I I I I I I I i 8/12/04 REVISED FIGURE 2 1 C- C7 O D CIDr O 0 m C CnD'uDr 7o [n F- 0 M M < 0 rrl - omrn<orm G-) D -� Am ;vmD Gn z _I OY �D ODD p — N o II Dmf z O m O m m O p r I m oc z>o I D D Zm2: X 0 m U) G7 G) co D m �x I \z7 =� h0 D 00 n K: 11 II � Co om Mm O Ncyl 0 cn O cn O D II Amo O --- M_ =m_ o O 0 W (/) 2 Cn m wC/) m 01) II cD O G7 TI -A m --j -A m OO—mc z DDG-) c) rr==W C O-90 Om D �mmOm n m D m n I=nm D �O�=Z --A CAO O O mz �=zmm cn D=ZLn E =1 W m I I Cn u cn m� D I m cn Z rn _ m O m Fri = n om COKn moo= ;umD m OXK CD D m r U) U) m �m O D =Op D Dr m zm m z c mo z D c ---I C O Ln z z c) -o I u n D r� O C7 Oo I o O = c-) c mD r x OO n r z x m W 0 o O 1 = O p O C T N U V^/ D \ TJ N �41 z o -i c O O � n71 II M mw C:) T1 U) D M D � r r 00 O O \ D (n ;o N z 0 m z 0 z G7 m D m r M U 2 m D O) K --�D m o z n A m A m� 0 0 DT Z� Zm Z T 0 K s m u m T m n 0 C 0 r 1 0 m O m 0m r- r m mz v m m m �W mr B 0 C. z O Ti r r g pm � =m U) C) m > w O Ol Z m < O m z m u O D C) Zu O Cf) (/') Cn m C) O z I Z Cn ---1 O D r I -Tl m Z7 m z O FTI CIO � O r O C b r 00 m yo � On ZO DMD� Z \ o G z C„i U �< w p �l O = IM m 00 m OD JOS On ZO DMD� C 0m r- r m mm mz Zm m M n� �W mr m T- o z p L- CD CD LL C N W liec cda CD Qi L U C O U 4-7c Nc C co 0- E U ?1 7 C /O V i O O N W ~ � 0 J � 0 LLI J O Wm � � J Q W CD O F W U Q Vj J J W U) of Z_ U W Q CO 4 LL � � Z N moo, EO N O^i (n v W E O O H J = F- 3 Z w w w = o IL N W � LY Q p 0 � Y Q Q U Z p F— O > Q w < F- W F- Z U - t- Q O� x U W p -J O U JLLI N !� LL .LLi II- ry w Z� D� O O tz ry V LL W CD Q W S U U U) 0 O F- W w J > LL I w cl� LU O Ll - LU W Q F- m F- W J Z V) W U W ER O W C� Q S U U) C7 Z_ F - Q J D 0 O z U7 F- IY O W F- W J Z F- J D Q LU O 0 tY F - <Y Q U a W F- J LL a W OJ Q > LL- z w J O Q O S Qv Z Q > W W Z U) Q LLJ CL LL W IL O Q J O W mQF- OW J N S m ~ Q Lli Q IL U U Q x w J_ W F' Z LU D J LL LL W W m D O m W_ IY W O O O I -- LL Ln M CDN d U L c �3 c c' v E O) N 17 +y O a' c CD N CL r'A Q CL O U co !n U J W U O Q =cy CLuj Z � cn U IL Z tY O (n OW Y W S W CL X ? W 2 2 F- F -UW W m U LU U) 0 - Q u. Ono Qf w ZZC)f W w O m z Z0 Q F- 2 = Z ~ U Q ui Q O W Z m OS O p Z Qom ] Cif O< J U a- Q w Z Q W U QO Q Z = LU U)Qf=0 Q 0 J m 05 = Q O 2 H Z C/)U 0f O 2 u F- U 5 LU O O zz J LL Z W U W WLjW2 2 z -i c/>—wo CL 7- r Q Q � WY� F -0Z Q Z Z O 0 LU Z O O O Z COZ (� �tCOd' O Lo N CC W v 0 M LLJ O (A w Er Cc W VZ z W Q � � J LL ULL LLJ a W W D U0 � m 7C)Z5 0 Cl) CP (a� O m zl- 0 U0 1 O co 3 -D ai N Cc c caro= a) CL TL c] O 5 LO Q lzr Q Q W J O ZW Q C/) j IL F- W 0 J Z -Ua U O J Ili cl� LU O Ll - LU W Q F- m F- W J Z V) W U W ER O W C� Q S U U) C7 Z_ F - Q J D 0 O z U7 F- IY O W F- W J Z F- J D Q LU O 0 tY F - <Y Q U a W F- J LL a W OJ Q > LL- z w J O Q O S Qv Z Q > W W Z U) Q LLJ CL LL W IL O Q J O W mQF- OW J N S m ~ Q Lli Q IL U U Q x w J_ W F' Z LU D J LL LL W W m D O m W_ IY W O O O I -- LL Ln M CDN d U L c �3 c c' v E O) N 17 +y O a' c CD N CL r'A Q CL O U co !n U J W U O Q =cy CLuj Z � cn U IL Z tY O (n OW Y W S W CL X ? W 2 2 F- F -UW W m U LU U) 0 - Q u. Ono Qf w ZZC)f W w O m z Z0 Q F- 2 = Z ~ U Q ui Q O W Z m OS O p Z Qom ] Cif O< J U a- Q w Z Q W U QO Q Z = LU U)Qf=0 Q 0 J m 05 = Q O 2 H Z C/)U 0f O 2 u F- U 5 LU O O zz J LL Z W U W WLjW2 2 z -i c/>—wo CL 7- r Q Q � WY� F -0Z Q Z Z O 0 LU Z O O O Z COZ (� �tCOd' O Lo N CC W v 0 M LLJ O (A w Er Cc W VZ z W Q � � J LL ULL LLJ a W W D U0 � m 7C)Z5 0 Cl) CP (a� O m zl- 0 U0 1 O co 3 -D ai N Cc c caro= a) CL TL c] O 5 LO Q lzr Q o c APPENDIX A 5721 SNOWMASS CREEK ROAD HEPWORTH-PAWLAK GEOTECHNICAL, INC. PERCOLATION TEST JOB NO. 104 428 JUNE 23, 2004 08/02/2004 14:45 9709274635 06/28/2004 12:05 97092337 HFPWORTH-PAWLAK GEOTECHNICAL ime 23, 2004 KCSMITHBUILER MARTIN t{cnwaah-f'uwlak Geotechnical. Inc. 502C Goun'V Ruud 154 U1en1rvoJ 50ng9, Lolvrac" 81601 Phvnc 970.945-79U lino: 970-()45-M54 email; KrFr4hrgenteehxom PAGE 01/08 PAGE 81 tan and Art Martin e% Hagman Architects Attn: Tony Major 0123 Emma Road, Suite 200 Basalt, Colorado 81621 Job No.104 428 Subject: Subsoil Study for Foundation Design and Percolation Test, Proposed Residence, 5721 Snowmass Creek Road, Pitkin County, Colorado. Dear Mr. and Mrs. Martin; As requested, Hiepworth-Pawlak Geotechnical, Inc. performed a subsoil study and percolation test for foundation and septic disposal designs at the subject site. The study was conducted in accordance with our agreement for geotechnical engineering services to you dated May 21, 2004. The data obtained and our recommendations based on the propmd construction and subsurface conditions encountered are presented in this report. Proposed Con The proposed residence will be a single story wood frame structure over a walkout basement level located on the site as shown on I iguze 1. The attached garage and basement floors will be slab -on -grade. The residence will be about 5,000 square feet in size, Cut depths are expected to range between about 4 to 12 feet. Foundation loadings for this type of construction are assumed to be relative light sed to be typical of the proposed type of consttucti e proposed residence. s proposed located about 40 feet downhill to the northeast of th If building conditions oddloadings rgsaaer ficantly diff6rent from those described abovewe shoulbenof toeluatthe recommendations presented in his report. Site Conditions: The site is currently a fenced horse pastcSome netted by a sham are done f'or construction of the dirt road to the west. Two pondsground surface a the located to the north and west of the proposed building area. The go building area slopes moderately steep down to the northeast at aboutng area. vegeta160/9 $tion consists e. There is about to to 14 feet of elevation andweeeeds. ce across the bu Several cobblesandd boulders are exposed on the of scattered scruboak, grass ground surface. Subsurface Conditions: The subsurface conditat the ions were evaluated e s by excavating two exploratory pits in the building �e and one ptic disposal area at the approximate lot ountered, belvshown on luabout 2 to 2V2 feet of tof the opsoil, 1 w , presented on Figure 2. The subsoils generally consist of relatively dense, sandy clayey gravel with cobbles to the excavated Parker 303.841-7119 • Colorado Springs 719-6.33-5562 • Sttverrhorne 970-468-1989 08/02/2004 14:45 9709274635 KCSMITHBUILER � 06/2B/2004 12:05 97092337"14 MARTIN PAGE 02/08 PAGE 02 -2- deptbis of 71h to 8 feet. Results of a gradation analyses performed on samples of the gravels (minus 5 and 6 inch fraction) obtained from the site are presented on Figure 3. Atterberg limits testing showed the clay matrix to have low plasticity- Groundwater was encounterred in Pit 1 at a depth of 7 feet. No free water was observed in the other pits at the time of excavation and the soils were slightly moist to wet below the water level in Pit l Slotted PVC pipe was installed In each of the pits for groundwater level monitoring. Foundation Recommendations: Due to the relath� d b ke t groundwater tndwively ter en ollow otered in Pit 1 and the nearby ponds, excavation depths s P avoid encountering water. Groundwater at Pit 1 was encountered above expected excavation depth and a basement level may not be feasible in this area. Considering the subwil conditions encountered in the exploratory pits and the nature of the proposed construction, we recommend spread footings placed on the undisturbed natural gravel soils designed for an allowable soil bearing pressure of 2,500 psf for support of the proposal residence. Footings should be a minimum width of 16 inches for continuous walls and 2 feet for columns. Loose and disturbed soils encountered at the foundation bearing level within the excavation should be removed and the footing bearing level extended down to the undisturbed natural gravel soils. Exterior footings should be provided with adequate cover above their bearing elevations for frost protection. used in this Placement of footings at least 42 inches below the exterior geode is typically area. Continuous foundation walls should be reinforced top and bottom to span local anomalies such as by assuming an unsupported length of at least 10 feet. Foundation walls acting as ret 4lirag structures should be designed to resist a lateral earth pressure based on an equivalent fluid unit weight of at least 50 pcf for the on-site soil, excluding vegetation, topsoil or oversized rock, as backfill. yloolr !ilabe: The natural on-site soils, exclusive of topsoil, are suitable to support lightly loaded slab -on -grade construction. To reduce the effects and columns derential i th expansion jointsfloor slabs should be separated fi°m all wring walls which allow unrestrained vertical movement. Floor slab control joints should be used to reduce damage dues to shrinkage cracking. The requirements for joint spacing and slab reirzforz=emarit should be established f € free-drathe i ning a gravelshauld be placed beneath on experience and the ended slab um. A minimum 4 inch layer o 8 basement level slabs to facilitate drainage. This material should consist of minusthe inc aggregate with less than 50% passing the No. 4 sieve and less than 2% passing o. 200 si eve. All fill materials for support of floor slabs should be compacted to at least 95%of fill can iataximum standard Proctor density at a moisture content near optimum. Req uiredeonsisit of the on-site soils devoid of vegetation, topsoil and oversized rock. e expected Uiaderdt"stin System: Free water e�th °sores that groundin Pit I water lve evels can rise and Local excavation depths. It has been our experience _ percbed groundwater can develop f rang ��� Of eieavY c precipitation We recommend o Frozen ground during spring tuff protected from below -grade construction, such as retaining walls and basement areas, be wet ling and hydrostatic pressure buildup by an underdrain system. lob No 104 428 mar. 08/02/2004 14:45 9709274635 KCSMITHBUILER PAGE 03/08 06/28/2084 12:05 97092337. MARTIN `~ PAGE 03 -3- The drains should consist of drainpipe placed in the bottom of the wall backfill surrounded above the invert level with f}ee•draining granular material. The drain should be placed at each, level of excavation and at least I foot below lowest adjacent finish grade and[ sloped at a minimum 1% to a suitable gravity outlet. Free -draining granular material used in the underdrain system should contain less than 2% passing the No. 200 sieve, less than 500/6 passing the No. 4 sieve and have a maximum size of 2 inches. The drain gravel backfill should be at ]cast 2 feet deep and extend up to any seepage encountered in the side of the excavation. SurfaceDrainage: The following drainage precautions should be observed during construction and maintained at all times after the residence has been completed: 1) Inundation of the foundation excavations and underslab areas should be avoided during construction. 2J Exterior bacUill should be adjusted to near optimum moisture and compacted to at least 95% of the maximum standard Proctor density in pavement and slab areas and to at least 90°/0 of the maximum standard Proctor density in landscape areas. Free -draining wall backfill should be capped with about 2 feet of the on-site, finer graded soils to reduce surface water infiltration. 3') The ground surface surrounding the exterior of the building should be sloped to drain away from the foundation in all directions. We recommend a minimum slope of 12 inches in the first 10 feet in unpaved areas and a minimum slope of 3 inches in the first 10 feet in pavement and vyal!(way areas. �I) ould discharge well beyond the limits of all Roof downspouts and drains sh backfill. Pereols.tion Testing: Percolation tests were conducted on June 8, 2004 to evaluate the fenibilixy of an infiltration septic disposal system at the site. One profile pit and three percolation holes were dug at the locations shown on Figure 1. The test holes (nominal 12 inch diameter by 12 inch deep) were hand dug at the bottom of shallow backhoe pits and were soaked with water one day prior to testing. The soils exposed in the percolation holes are similar to those exposed in the Profile Pit shown on Figure 2 and consist of about 2 feet of topsoil and 2 feet of stiff, sandy silty clay overlying sandy clayey gravel with cobbles to the pit depth of 8 feet. The percolation test results are presented in Table 1. Based on the subsurface conditions encountered and the percolation test results, the tested urea should be suitable for a conventional infiltration septic disposal system. Pitkin County' requires that a professional engineer design the infiltration septic disposal system. Limihitions: This study has been conducted In accordance with generally accepted geotechnical en0eering principles and practices in this area at this time. We make no warranty either expressed or implied. The conclusions and recommendaits tions aced asubmit the to this report are based upon the data obtained pe the exploratory p locations indicated on Figure 1, the proposed type of construction and i opene�nce n the area. Our services do not include determining the presence, pr possibility of mold or other biological contaminants (MOSC) developing in the future. If the client job N9. 1,04 429 Gem 08/02/2004 14:45 9709274635 KCSMITHBUILER PAGE 06/28/2004 12:05 97092337. MARTIN -4- PAGE 04 is coneermed about MOBC, then a professional in this special field of practice should be consulted. Our fundings include interpolation and extrapolation of the subsurface conditions identified at the exploratory pits and variations in the subsurface conditions may not become evident until excavation is performed. if conditions encountered during coustrttction appear different froth those described in this report, we should be notified at once so re-evaluation of the recommendations may be made. This report has been prepared for the exclusive use by our client for design purposes. We are not responsible for technical interpretations by others of our information. As the project evolves, we should provide continued consultation and field services during construction to review and monitor the implementation of our recommendations, and to verify that the recommendations have been appropriately interpreted. Significant design changes tnay require additional analysis or modiftcation5 to the recommendations presented herein. We recommend on-site observation of excavations and foundation bearing strata and testing of structural fill by a representative of the geotechnical engimeer. If you bane any questions or if We may be of further assistance, please let us know. Respectfully Submitted, HEPWORTH - PAWLAK GEOTECHNICAL, INC. J1 R Daniel E. Hardin, P.E. 3ZA/ksw attachments Figure 1— Location of Exploratory Pits and percolation Test Holes Figure 2 — Logs of Exploratory pits Figure 3 — Oradation Test Results Fable l — percolation Test Results Jvb N9.104 423 C�e'C7oes� OB/02/2004 14:45 9709274635 KCSMITHBUILER PAGE PAGE 05 'MARTIN 06/28/2004 12:05 9709233714 05/08 08/02/2004 14:45 9709274635 06/28/2004 12:05 97092337,. 0 0 I � CL ea 10 LEGEND: KCSMITHBUILER MARTIN PAGE 06/08 r PAGE 06 0 TOPSOIL; silty gaudy grovsl, organics. firm, moist, dark brown. 11 CLAY (CL): slity, sandy, stiff, moist, brown, low plasticity. '• k GRAS (CC); clayey, sandy, with cobbles, dense, motet. wet below water in Pit 1, brown, subangular rock fragments. �g 2" Diameter hand driven liner sample_ Disturbed bulk sompie. TPractical dtgging refusal. Ltd Indleates slotted PVC pipe installed In pit to depth shown. NOTES: 1. Exploratory pits were excavated on June 7. 2004 with a beekhoe_ 2. Locations of exploratory pits were measured approximately by pacing from features shown on the sats pian provided. 3. Elevations of exploratory pita were obtained by interpolation between contours on the site plan provided and checked by instrument level. Logs are drown to depth. 4. The exploratory pit bastions and elevations should be considered accurate only to the degree impiled icy the method used. the exploratory pit log® represent the approximate boundaries 5. The lines betwsso materials shown on uetween material types and transitions may be groduol. a. vVater level readings shown on the togs were mode at the time and under the conditions ind�coted. i•luctuation in water level may occur with time. 7, Laboratory Testing Results: Liquid Limit (R ) +4 - Percent retained on the No. 4 sieve P plasticit index -Z00 = Percent passing No_ 200 sieve HEPWORTH-PAWLAK LOGS OF EXPLORATORY PITS Figure 2 104 428 �C}TECi-iNICAL, INC. PIT 2 PROFILE PIT PIT 1 ELEv_- 7847' ELEV.= 7839' EL.E\r.= 7830' 0 • i , +x.,60 n _ -100-39 - w-12 to 0 TOPSOIL; silty gaudy grovsl, organics. firm, moist, dark brown. 11 CLAY (CL): slity, sandy, stiff, moist, brown, low plasticity. '• k GRAS (CC); clayey, sandy, with cobbles, dense, motet. wet below water in Pit 1, brown, subangular rock fragments. �g 2" Diameter hand driven liner sample_ Disturbed bulk sompie. TPractical dtgging refusal. Ltd Indleates slotted PVC pipe installed In pit to depth shown. NOTES: 1. Exploratory pits were excavated on June 7. 2004 with a beekhoe_ 2. Locations of exploratory pits were measured approximately by pacing from features shown on the sats pian provided. 3. Elevations of exploratory pita were obtained by interpolation between contours on the site plan provided and checked by instrument level. Logs are drown to depth. 4. The exploratory pit bastions and elevations should be considered accurate only to the degree impiled icy the method used. the exploratory pit log® represent the approximate boundaries 5. The lines betwsso materials shown on uetween material types and transitions may be groduol. a. vVater level readings shown on the togs were mode at the time and under the conditions ind�coted. i•luctuation in water level may occur with time. 7, Laboratory Testing Results: Liquid Limit (R ) +4 - Percent retained on the No. 4 sieve P plasticit index -Z00 = Percent passing No_ 200 sieve HEPWORTH-PAWLAK LOGS OF EXPLORATORY PITS Figure 2 104 428 �C}TECi-iNICAL, INC. i � rel �•��lr�! ���w �.— ��_�.� �� rte• • �� �� A�•� �• ��l� �i� �Y— !^ r � �• K� r� �_ �^w��iirr ��lw• __ �rr.w� i!� ���r� Orli i•�••l il1A�'�!� �►ire^— !_s.•�•s Imo! �r�• �i•�������1l� !^nom• Y��� .rte � r,"��'-^ ii� �.�r�i �'=r�•�r�i.�i ^����� i ���r^ ���r•�"=r �_�•r^err"rr�o +�. 373DIAMETER OF PARTICLES IN MILUMVERS DAY 78 ILT SILT AmD CLAY 38 z GRAVEL 42 % SAND 20 INDEX SAMPLE • Sandy • Oravel with Cobbles • ^,UK AFAUP10 I mL =4 MIL +lam+l�.�����.r •�^—�+•�..r �w +�rr�^"•'��-�w.��r��� r^�r� —� rte! =r.. r� r+�•� fir• �� HEPWORTH—PAWLAK GEOTECHNICAL. INC. 08/02/2004 14:45 9709274635 KCSMITHBUILER PAGE 08/08 06/28/2004 12:05 97892331463 MARTIN PAGE 08 HEPWORTH-PAWLAK GEOTECHNICAL, INC. TABLE 2 PERCOLATION TEST RESULTS 305 NO. 104 426 OF INTERVAL (MIN) WATER OEM AT STARTL VAL WATER DROP IN DEMAT WATER INTERVAL (INCHES) AVERAGE PERCOLATION RATE (MIN./ NCH) HOLE NO. HOLE DEPTH (INCHES) INCHES INCHES 13 10 10 3 81/z 1 Yz P-1 42rwateradded 81h 7Y2 1 13 VA 11 11 2Va 9 2 g 81/4 '/i 81/4 71/2 3/4 7+/2 634 2/4 20 71/2 6% 61% DA 6 2/4 P -Z 45 15 6 5'/2 'h 51h 5Y4 1 1/4 5'/1, 04 4% 41/2 3`4 41/2 41/4 4Ys 4 I/4 60 64 i5 834 8 8 3k 7+/2 '/z P-3 7V2 7 '/2 7 6'/2 '/z 61/z 6,/4 Ya 61A 6 Va 6 51/251/4 51/2Y2 1 /a i 45 Note: Percolation 7, 2004. roW were hand tests on the last three onducted onIn the readings of bJune 8OM f 2004. e pits and Theaverage each test. on perco at once test holes Percolation were based ALAI, R I CHMAN 9709201 5 497 f lifil �� page' 1 of 5 1111111111111111111 III III 1 05/03/2004 11:4711 SItivIR 0AVt$ OSTKIN COUNTY C9 R 0.00 0 0,00 P.01 DETERMiNATiON OF THE BEARING OFFICER OF THE COMMUNITY DEVTI,U;< MV -NT DEPARTMENT OF PTTKIN COUNTY, COLORADO, APPROVING THE SNOWMASS CREEK RANCH LLC: 1041 HAZARD REVIEW, CONCEPTUAL SUBMISSION, GMQS EXEMPTION AND DEMOLITION EXTENSION Deter inination No. i�-2004 RECITALS 1. Snowrnass Creek Ranch LLC ("Applicant") has applied to the Pitkin County Hearing Officer ("Hearing Officer") for approval of a building envelope, within which to build a replacement residence. The parcel is located 5721 Ssiowmass Creek load, and is described as Parcel B, Schubert Subdivision Excriptron. The parcel contains 40.10 acres and is a conforuung size parcel in the RS-30/PUD zone district. 4. The parcel was created prior to June 12, 1978, therefore, the proposed replacement dwelling unit is exempt from growth management up to 5,750 square feet of floor area. Pursuant to Resolution No. 80-123, the $UCC approved the Schubert Subdivision );xemption, which reconlzgtired two ad_iacellt parcels. The BOCC subsequently granted special review approval for an Employee Dwelling Unit within the existing bam, pursuant to Resohition No. 84-100, 6. The fearing Officer considered this application at a duly noticed public hearing on April 20, 2004, at which time evidence and testimony were presented with respect to this application. The Hearing Officer finds that the proposed building envelope is located on slopes of less than n, Il,e wildfire hazard is rated as mi,derate and can he mitigated, and that the development will have insubstantial impacts on wildlife. NOW THEREFORE BE IT RESOLVED by the Pitkin County Commuliity Development 14earing Officm that he does hereby approve the 5nowmass Creek Ranch 1,1 ,C 1041 Hvard Review, conceptual Submission, CMQS Exemption and Demolition Extension, subject to the following conditions, wl,icl, shall nin with the land and he binding on all successors in interest. i . Prior to submission of any earthmoving, access, or building permit applications, the Applicant shall Submit a 1041 Hazard Review Site Plan to the Community Development Department for approval and recording. The mylar copy of the site plan mast he signed by the owners prior to submittal for recording. Prior to recordation, the site plan shall be amended to designate an envelope for the underground water tank along the driveway spur above the ranch road. M Prior to submission of a septic petx>iit for the new residence, the Applicant shall pt'ovide docun-rWMIOn of an adequate domestic water supply on the property. Quantity and quality of said supply shall meet the approval of the Environmental Health Department. he Applicant shall 3, Prior to issuance of any building permits for the new residence, t ALA CCHMAN 9709201'5 P.02 r imu-ing Officer Deierminution A'Vo. W-2004 Inge % 497104 1` tll� i 1�� 11� III 05gM/2004 11 A M 11� 5ILVIR NVt5 PITKIN COUNTY CO R 0.00 n 0.00 A. Execute a guarantee, including financial security, that the upper cabin will be converted to an agricultural building (rendered not a dwelling unit) before a certificate of occupancy is issued for the new residence. B. Execute a guarantee, including financial security, that the lower cabin (trailer) will be removed by October 15, 2004. C. Submit a mitigation report from an engineer or geologist licensed in the State of Colorado. The report shall demonstrate that the site can be engineered M such a way that there is no hazard hosed, and shall show the area of disturbed slopes, any re -grading required and the size and location ofall nnitivation devices. Any new development shall be conditioned upon compliance with the report. D. Complete a fireplace/woodstove registration form with the Community Development Department, if necessary. E. Obtain an access permit to iarlprove the driveway, if required by the County Engineer or Basalt and Rural Fire Protection District, F. Submit a drainage and erosion control plan for review and approval by the County Engineer. G. Submit a construction management plan for review and approval by the County Engineer showing the locations of staging, material storage and employee and construction traffic parking_ No staging may occur on County roads. l -l. Pay the applicable road impact fee. 1. Obtain approval of aseptic permit from the Environmental Health Department. The wptic system shall tie located within the approved buildumg envelope, and must comply with the setback requirements from surface and groundwater sources. A qualified professional engineer must design the systetn. J. File a Storm Water Management Plan with the State of Colorado, if required, and provide a copy of the approved plan to the County. -l. The replacement residence is exempt from growth management up to 5,750 square feet of floor area. �. prior to commencement of any earthmoving or construction activity, the Applicant shall stake the corners ofthe building envelope and install construction fencing around the perimeter of the building envelope. The fencing shall remain in place until a Certificate of Occupancy is issued for the residence. 6. Ilie Applicant shall comply with the following landscaping and wildfit•e defensible space mitigation standards: A. for a distance of 10 -.around all structures, maintain vegetation at a height of 6" or less with mowed grass, low growing perennials or hardscape. Woody. vegetation shall not be planted within this perimeter. B. Vegetation shall be reduced to break up the vertical and horizontal continuity of the fuels a. minimum of 60' around all structures. C. Spacing between clumps of brush and vegetation within► 30' of all structures shall be a minimum of three times the height of the fuel. Maximum diameter of the clumps shall he two times the height of the fuel_ All rneasurernerds shall be from the edges of the crowns of the fuel. ' ALAN RICHMAN 9709201AT P.03 r., fleurine Officer ,Determination No, 171-2004 Pug,e 3 II �I 497104 IPage: 3 of 5 �f � IIjjI� 03/200 12 4 SILVIA DAVIS PITKIN COUNTY CO R 0.00 b 0.00 D. All branches from trees and brush within 30' of all structures shall be pruned to a height of 1.0 feet above tine ground and ladder fuels from around trees and brush shall be removed. E. Tree crown separation within 30' of all structures shall have a minimum of 20 feet between the edges of the crowns, except for aspen trees, where crown spacing may be 8 feet. F. All branches that extend over the roof eaves shall be trinuned and all branches within 15 feet of the chimneys shall be removed. G. From the 30' perimeter around the residence out to the 60' perimeter, brush and shrubs shall be thinned to 2 times the height of the fuels. For sagebrush (or shorter brush species), thin stands to 4 times the height of the fuel. H. All deadfall within the 100 foot perimeter shall be removed. I. The Applicant shall be responsible for the continued Inaintenancc of tl)e defensible space vegetation requirements. 7. The Applicant shall comply with the following additional wildfire mitigation standards: A. Roofs shall be constructed with a Class A roof covering ora Class A assembly as defined in tl)e U13C 1997 Section 1504. Wood shake/shingle roof coverings are prohibited. Roofs with less that) a 3:12 pitch are not permitted unless they comply witl) the following: I ) All roof coverings shall be noncombustible materials as defined in the Uniforn) Building Code (UBC) 1997 Section 1504 and installed on a Class A roof assembly. 2) All roof coverings shall have a Surflce that shall facilitate the natural proc:css of clearing the roof. 3) All roof designs shall facilitate the natural process of clearing roof debris. Protrusions above the roofline, such as parapets, shall be prohibited. 4) Roofs shall be installed as required by LJBC 1997 Chapter 15 and shall hava a minimum slope of 1:48. 5) All roof designs, coverings, or equivalent assemblies shall be specifically approved by the Fire Marshal prior to submittal of a building permit application_ B. Vents shall be screened with corrosive resistant wire mesh with mesh '/a inch maximum. C. Roofs and gutters shall be kept clear of debris. U. Yards shall be kept clear of all litter, slash, and flammable debris. E. All flsg)nmahle materials and firewood/wood piles shall be stored on a parallel contour a minimum of 15 beet awav front any structure. F. Weeds and grasses within a 10 foot perimeter of all structures shall be maintained to a height of not nl ore than 6 inches. G, Switr.ming pools or ponds shall be accessible to Fire Department vehicles. H. Fences shall be kept clear of brush and debris. 1. Wood fences shall not connect to the structure. J. Fuel tanks shall he installed underground with an approved container. K. Proprine tanks shall he installed according. to NFP A 4$ standards and on a contour a,,vay from the structure with standard defensible space vegetation mitigation around any above -ground tank. Any wood enclosure around the tank shall be constructed with materials approved for 2 hour fire - resistive construction on the exterior side of the walls. L. Each structure shall have a minimum of one 10 pound approved ABC fire extinguisher placed in a visible and accessible location. ' ALA?#bR I CHMAN 9709201'''5 P.04 r 497104 5 . (,�� 05/03/2004 1:478 'i er eterjt�irtafivtz No. i�-2(lU4 a N� �r �' 4 SILVIA DQVIt, PITKIN COUNTY Co R 0.00 M. Addresses shall be clearly marked with 2 inch non-combustible letters and shall be visible and installed on a non-combustible post. N. New utility lines shall be buried within or along the driveway. U. A residential sprinkler system shall be installed if the residence exceeds 5,000 square Ceet. P. Provide an on-site water supply that will be available for year-round use to the satisfaction of the Basalt fire Marshal. $. The Applicant shall comply with the following to mitigate inhpaets on wildlife: A. Installation and use of approved bear -proof trash containers is required, Verification of this condition shall be required prior to issuance of a certificate of occupancy. f3. .Dogs shall be kenneled C. Native vegetation shall he maintained outside of the building envelope. D. Fruit -bearing trees and shrubs should be avoided in any landscaping due to the high level of black bear activity in this area. E_ Fencing outside the building envelope shall comply with the following. Wood fencing shall employ three rails or less, be the round or split rail type, shall not exceed 48 inches in height above ground level and 12 inches in width (top view), and shall have at least 18 inches between two of the rails. Wire fencing shall consist of no more than 3 strands of smooth wire and shall not exceed 42 inches in height. The existing fencing along Snowntass Creek Road shall be modified by removing the bottom rail in at least three locations as approved by the County NIVildlife Biologist. F. Any areas disturbed outside the building envelope shall be revegetated with native plants according to a revegetation plan? submitted by the applicant and approved by the County prior to issuance of a certificate of occupancy. 9_ Exterior lighting shall comply with the regulations of the Land Use Code in effect at the time of installation. 10. No develepnient, including; grading, exeavatiotl, fill placement, berming, landscaping, vegetation removal or disturbance, entry or ranch gates, or septic systems shall occur outside of the approved building envelope, except as may be necessary to implement the wildfire mitigation measures required elsewhere in this docunhent. 11. All area,, disturbed by construction shall be revegetated to limit water consumption and additional runoff wi-hin one growing season after completion of construction. 1 �. failure to cornply with these conditions of approval may result in revocation of this permit or any subsequent permits related to this property or vested rights associated with this prot)erty. 13. The Applicant shall adhere to all material representations made in the current or prior applications or in public rnectings or Bearings and shall consider those representatiolhs to he conditions of approval, unless amended by other conditions. 14. Statutory vested rights for the approval contained therein are granted pursuant to the Pitkin County Land Use Code and Colorado Statutes, subject to the exceptions set forth in pitkin County' Land 1Jse Code. § • ' ALAN .d I CHMAN 97092011' S P.05 E flcaring (Wicer Determination No. 111-2004 Doge 5 497104 S! 05163/2004 11:47A 11� 1 S[LVIA DQVIS ptTKIN COUNYY Co R m.00 D @•@a 4-140 and C.R.S., § 24-68-105. The statutory vested rights granted herein shall expire on April 20, 2007. NOTICE OF PUBLIC HEARING PUBLISHED IN THE ASPEN TIME S WEEKLY on the 20°' day of March, 2004, APPROVED AND ADOPTED this 20`x' day of April, 2004• PUBLISHED AFTER ADOPTION FOR VESTED REAL PROPERTY RIGHTS in the As�_'fimes Weekly oil the J. } day of 2004, ATTES . Janis Ta_ or, .A,dnuuistrativ Assistant APPROWD AS COMMUNITY DEVEUOPW'NT DEPARTMENT HEARING OFFICER OF PITKIN COUNTY, COLORADO 13 Jam s R. True, Hearing Obiter Date APPROVED AS TO CONTENT- ��------------- JONI El iri Houben, Couyey Attot�rr Community Development Director ITi3-N PIw2645143(ff02 5000 GALLON CISTURN 25' SETBACK r PLACE CLEANOUT OUTSIDE FOUNDATION 3 -BEDROOM APARTMENT LOG HORSE ARENA/BARN r rr O r , C11 .'ENCASE SEWER rrrrr PIPE WITH O SCHEDULE 40 PVC /r UNDER DRIVE TOPOGRAPHY AT 1 FT r'f EXISTING SEPTIC INTERVALS (f TANK AND f DRYWELL TO BEr / ABANDONED r 558 SF OF INFILTRATIVE AREA IN THREE GRAVELLESS TRENCHES TRENCHES = 3 CHAMBERS PER TRENCH = 12 TOTAL CHAMBERS = 36 DISTRIBUTION BOX OR FLOW SPLITTER BASIN / UVII[FOINAvr'_ ONE 1500 -GALLON, TWO-COMPARTMENT, PRECAST CONCRETE SEPTIC TANK WITH EFFLUENT FILTER IN SECOND COMPARTMENT ELECTRICAL BOX STEEP SLOPE TO SNOWMASS CREEK PIPE MAY BE PLACED IN 8, ROUND SPRIKLER BOX TO MAINTAIN ACCESS TANK SPECIFICATIONS CAPACITY REQUIRED = q X 1.75 X (30 HOURS/24 HOURS) _ 1312.5 GALLONS REQUIRED TANK = 1500 -GALLON, TWO COMPARTMENT, CONCRETE SEPTIC TANK WITH EFFLUENT FILTER ON OUTLET 3 -BEDROOM TANK OPTION = 1000 -GALLON, TWO COMPARTMENT, CONCRETE SEPTIC TANK WITH EFFLUENT FILTER ON OUTLET DUE TO THE AGE OF THE EXISTING TANK IT SHOULD BE REPLACED. IF THE OWNER WOULD LIKE TO INVESTIGATE THE INTEGRITY OF THE EXISTING TANK, THE TANK MUST BE PUMPED AND EXCAVATED FOR ALL SERVICE SEPTIC, LLC AND THE COUNTY TO EVALUATE. DESIGN FOUR - BEDROOM RESIDENCE, <2000 SF = 600 GALLONS PER DAY (75 GALS PER PERSON/DAY, 2 PERSONS PER BEDROOM) TOTAL LOADING = q = 600 GALLONS PER DAY PERCOLATION RATE = 27 MINUTES PER INCH CALCULATED AREA = ((1.75 X q) X sqrt 27) / 5 = 1092 SF REDUCTION OF 50% = 546 SF TRENCH SPECIFICATIONS WIDTH OF TRENCHES = 3 FEET = 1 CHAMBERS LENGTH OF TRENCHES = 75 FEET = 12 CHAMBERS TOTAL NUMBER OF CHAMBERS = 36 TOTAL INFILTRATIVE AREA = 558 SF THREE TOTAL TRENCHES (QUICK 4 INFILTRATOR CHAMBERS REQUIRES MINIMUM 56 CHAMBERS) THREE BEDROOM OPTION �` THREE - BEDROOM RESIDENCE, <2000 SF = 450�G�AL- NS PER DAY (75 GALS PER PERSON/DAY, 2 PERSONS PER Bf'DROOM) TOTAL -LOADING = q = 450 GALLONS DAY PERCOLATION RATE = 27 MINUT PER INCH CALCULATED A1�EA = ((1.7 q) X sqrt 27) / 5 = 819 SF REDUCTION OF 5000 '� SF WIDTH OF TRENCHES = 3 FEET, 1 CHAMBERS LENGTHAF TRENCHES = 56.25 FEET = 9 CHAMBERS TOTACNUMBER OF CHAMBERS = 27 TOTAL INFILTRATIVE AREA = 418.5 SF THREE TOTAL TRENCHES (QUICK 4 INFILTRATOR CHAMBERS REQUIRES MINIMUM 42 CHAMBERS) CROSS SECTION OF TYPICAL CHAMBER -TRENCHES • 4" PVC OBERVATION PIPE I 5.0' MAX LIMIT OF EXCAVATION GRAVELLESS CHAMBER rF-6' MIN►t SCARIFY SURFACE TRENCHES MUST BE LEVEL 1.5' MIN U i ' 1"=20' • rr � r • r 2 Compartment Septic Tank with 4" Dia. Biotube Effluent Filter • i r rr O r , C11 .'ENCASE SEWER rrrrr PIPE WITH O SCHEDULE 40 PVC /r UNDER DRIVE TOPOGRAPHY AT 1 FT r'f EXISTING SEPTIC INTERVALS (f TANK AND f DRYWELL TO BEr / ABANDONED r 558 SF OF INFILTRATIVE AREA IN THREE GRAVELLESS TRENCHES TRENCHES = 3 CHAMBERS PER TRENCH = 12 TOTAL CHAMBERS = 36 DISTRIBUTION BOX OR FLOW SPLITTER BASIN / UVII[FOINAvr'_ ONE 1500 -GALLON, TWO-COMPARTMENT, PRECAST CONCRETE SEPTIC TANK WITH EFFLUENT FILTER IN SECOND COMPARTMENT ELECTRICAL BOX STEEP SLOPE TO SNOWMASS CREEK PIPE MAY BE PLACED IN 8, ROUND SPRIKLER BOX TO MAINTAIN ACCESS TANK SPECIFICATIONS CAPACITY REQUIRED = q X 1.75 X (30 HOURS/24 HOURS) _ 1312.5 GALLONS REQUIRED TANK = 1500 -GALLON, TWO COMPARTMENT, CONCRETE SEPTIC TANK WITH EFFLUENT FILTER ON OUTLET 3 -BEDROOM TANK OPTION = 1000 -GALLON, TWO COMPARTMENT, CONCRETE SEPTIC TANK WITH EFFLUENT FILTER ON OUTLET DUE TO THE AGE OF THE EXISTING TANK IT SHOULD BE REPLACED. IF THE OWNER WOULD LIKE TO INVESTIGATE THE INTEGRITY OF THE EXISTING TANK, THE TANK MUST BE PUMPED AND EXCAVATED FOR ALL SERVICE SEPTIC, LLC AND THE COUNTY TO EVALUATE. DESIGN FOUR - BEDROOM RESIDENCE, <2000 SF = 600 GALLONS PER DAY (75 GALS PER PERSON/DAY, 2 PERSONS PER BEDROOM) TOTAL LOADING = q = 600 GALLONS PER DAY PERCOLATION RATE = 27 MINUTES PER INCH CALCULATED AREA = ((1.75 X q) X sqrt 27) / 5 = 1092 SF REDUCTION OF 50% = 546 SF TRENCH SPECIFICATIONS WIDTH OF TRENCHES = 3 FEET = 1 CHAMBERS LENGTH OF TRENCHES = 75 FEET = 12 CHAMBERS TOTAL NUMBER OF CHAMBERS = 36 TOTAL INFILTRATIVE AREA = 558 SF THREE TOTAL TRENCHES (QUICK 4 INFILTRATOR CHAMBERS REQUIRES MINIMUM 56 CHAMBERS) THREE BEDROOM OPTION �` THREE - BEDROOM RESIDENCE, <2000 SF = 450�G�AL- NS PER DAY (75 GALS PER PERSON/DAY, 2 PERSONS PER Bf'DROOM) TOTAL -LOADING = q = 450 GALLONS DAY PERCOLATION RATE = 27 MINUT PER INCH CALCULATED A1�EA = ((1.7 q) X sqrt 27) / 5 = 819 SF REDUCTION OF 5000 '� SF WIDTH OF TRENCHES = 3 FEET, 1 CHAMBERS LENGTHAF TRENCHES = 56.25 FEET = 9 CHAMBERS TOTACNUMBER OF CHAMBERS = 27 TOTAL INFILTRATIVE AREA = 418.5 SF THREE TOTAL TRENCHES (QUICK 4 INFILTRATOR CHAMBERS REQUIRES MINIMUM 42 CHAMBERS) CROSS SECTION OF TYPICAL CHAMBER -TRENCHES • 4" PVC OBERVATION PIPE I 5.0' MAX LIMIT OF EXCAVATION GRAVELLESS CHAMBER rF-6' MIN►t SCARIFY SURFACE TRENCHES MUST BE LEVEL 1.5' MIN U Idet COPELAND SEPTIC TANKS WITH CENTER HOLE IN BAFFLE ACCEPTABLE ALTERNATIVE condut Seal Patents 1 4,439,323 & 5,492,635 Foreign Patents Pending 020O2, Orenca System In. NOTES: NDW—TD-09 Rev. 1.0 (2/98) Tank Adapter (cwt or bolted) vent orifice Effluent Discharge Modulating Discharge Orifices Vault Inlet Parts Cartridge A Rter IF'QUICK-4' INFILTRATOR CHAMBERS ARE USED, ALL SERVICE SEPTIC, LLC SHOULD BE NOTIFIED TO CONFIRM MINIMUM NUMBER REQUIRED THE SLOPE AT THE PROPOSED DRAIN FIELD IS APPROXIMATELY 3% TO THE SOUTHEAST. VEGETATION CONSISTS OF A THIN COVER OF GRASS. LIMITATIONS - THESE PLANS MUST BE USED IN CONJUNCTION WITH LETTER AND SOILS DATA FORM PROVIDED. THE DESIGN IS BASED UPON INFORMATION SUBMITTED. IF SOIL CONDITIONS ENCOUNTERED ARE DIFFERENT FROM CONDITIONS DESCRIBED IN REPORT, ALL SERVICE SEPTIC L.L.C. SHOULD BE NOTIFIED. ALL OWS CONSTRUCTION MUST BE ACCORDING TO COUNTY REGULATIONS. THE INSTALLER SHOULD HAVE DEMOSTRATED KNOWLEDGE OF THE REQUIREMENTS AND REGULATIONS OF THE COUNTY IN WHICH THEY ARE WORKING. THE COUNTY AND ALL SERVICE SEPTIC L.L.C.MUST VIEW INSTALLATION ALL SERVICE septic, LLC 5721 SNOWMASS CREEK ROAD Project NO. 1040 PO BOX 2844 GLENWOODSPRINGS,C081602 SNOWMASS CREEK RANCH, L.L.C. REPAIR ONSITE WASTEWATER SYSTEM DESIGN FOR APARTMENT 11-15-04 970-618-5033 PITKIN COUNTY, COLORADO SCALE ' 1"=20' NORTH 2 Compartment Septic Tank with 4" Dia. Biotube Effluent Filter O Orenco Systems• Splice Boz w/Cad Grips ]�.WsW Rac or Concrete Risen with Graamet(s)F berglass Gaeketed Lid cert 914 rEtW Agm (bond d he")with Stainless Steel Bots 97a7s-W1201®aN Sbpe (round \ 19811afE: Away Fran Risen,_�..... (941) 151-4119 Conduit to -�>-�� i rm AlaPanel �i'� :....... 4 Inter Cartridge Handle fi (field at to desired height) rxiE.E (541) 4e9-2994 Idet COPELAND SEPTIC TANKS WITH CENTER HOLE IN BAFFLE ACCEPTABLE ALTERNATIVE condut Seal Patents 1 4,439,323 & 5,492,635 Foreign Patents Pending 020O2, Orenca System In. NOTES: NDW—TD-09 Rev. 1.0 (2/98) Tank Adapter (cwt or bolted) vent orifice Effluent Discharge Modulating Discharge Orifices Vault Inlet Parts Cartridge A Rter IF'QUICK-4' INFILTRATOR CHAMBERS ARE USED, ALL SERVICE SEPTIC, LLC SHOULD BE NOTIFIED TO CONFIRM MINIMUM NUMBER REQUIRED THE SLOPE AT THE PROPOSED DRAIN FIELD IS APPROXIMATELY 3% TO THE SOUTHEAST. VEGETATION CONSISTS OF A THIN COVER OF GRASS. LIMITATIONS - THESE PLANS MUST BE USED IN CONJUNCTION WITH LETTER AND SOILS DATA FORM PROVIDED. THE DESIGN IS BASED UPON INFORMATION SUBMITTED. IF SOIL CONDITIONS ENCOUNTERED ARE DIFFERENT FROM CONDITIONS DESCRIBED IN REPORT, ALL SERVICE SEPTIC L.L.C. SHOULD BE NOTIFIED. ALL OWS CONSTRUCTION MUST BE ACCORDING TO COUNTY REGULATIONS. THE INSTALLER SHOULD HAVE DEMOSTRATED KNOWLEDGE OF THE REQUIREMENTS AND REGULATIONS OF THE COUNTY IN WHICH THEY ARE WORKING. THE COUNTY AND ALL SERVICE SEPTIC L.L.C.MUST VIEW INSTALLATION ALL SERVICE septic, LLC 5721 SNOWMASS CREEK ROAD Project NO. 1040 PO BOX 2844 GLENWOODSPRINGS,C081602 SNOWMASS CREEK RANCH, L.L.C. REPAIR ONSITE WASTEWATER SYSTEM DESIGN FOR APARTMENT 11-15-04 970-618-5033 PITKIN COUNTY, COLORADO