Loading...
HomeMy WebLinkAboutpitkin.eh.264514401003 (1988)r ASPEN*PITKIN -.. ENVIF4-jNMENTAL HEALTH DEPAR't .iAENT INDIVIDUAL SEWAGE DISPOSAL PERMIT NO. TYPE OF PERMIT: nitialConstruction ( )Emergency Use ( )Repair Work,(Pievious Permit 1 .) ( )Alteration of an existing system, or installation (Previous Permit 1 ( )Use Permit as a result of Sale ( )Other: ISSUED TO: Owner . ( t U W 0J Mai]_ing Address S:il W"(f) " I ,_)c S DATE OF ISSUE .tj Home Phone Z _Zx usiness Phone 77-1 Agent 7CZ's`t i_.(ry�''} Phone — ob Ma i l.in g Address Sewage Disposal System Work to be performed by This permit valid' only for premises location by the following legal' description: � % 30 j LOT SIZE �1 t I Q(:u., . WATER SUPPLY (�;(�� lt;�dl AVERAGE PERCOLATION RATE This Individual Sewage Disposal Permit is granted with regard to the following use: Ai ! l� a• Nu•.:bcr of: Dodreoms i Lofts Carba a Disposals_ Dishwashers Clothes Washers CALCULATED AVERAGE DAILY WASTE LOAD GALLONS. THE NATURE OF 'THE SYSTEM INCLUDED UNDER THIS PERMLIT: ■ Typ.a of Tank or Treatment Units Tank. Capacity_• 6 ) Callon Minlmu:a rj Method of Final Disposal: B ^ T • s y �+ -. Absorption Area 5 4otJ Square Feet Minimum Description (including brand name, if any) of other equipment or appurtnancest .0th on Cdition! or Specificationst. L�iS��LV / �L (I�JQ •+G 6O weec dES�(3^J �ij� ly�,p v j4I/r ) DA�en �NC�(N,r.��-�/?Z,6�► t� t°5c� —c3�) �be�JA�i� jg6e, (A4 ,64eA STAGES REQUIRING INSPECTION BY THE HEALTH DEPARTMENT: ( )Before Excavation ( )Upon completion of excavation and prior to placement of gravel ( )Before covering distribution system of absorption field >�?_ rior to backfill of any component ( )Other, Specify: Plane and specifications of the proposed sewage disposal system have been reviewed and are considered satisfactory. Pernissi-on is hcreL-y granted to the owner or his agent to perform the work indicated above in accordance with the Pitkin County Indivi;ival Sewa,c DLrpesat Revelations in effect on the date of issue. In addition to general provisions set forth on the reverse hereof, this Permit is subject to the following additional terms and conditions: APPROVED FOR ISSUE A� BYE (title)N� E-66 5� �Ne The ahnve individual sevago disposal system installed by has txen inspected for use by a representative of the Aspen 1 -it in invlronr—feta )1calth Departinent. TEe uwnur asaurtws a ll re:;honsibiltty in case of f3ilurg or inadequacy of this sewaq disposal system. Complete as -built drawing attached. 2 F. DATE OF FINALW$PECT ON - /A /11 W69 iLN- o 7 6 - O$.^ B71:" TITLE Il/�OICr Ji 930 South Galen'i Street Aspen, Colorado 81611 303/925-2020 ASPEN#PITKIN ENVIRviVMENTAL HEALTH DEPARI.VIENT APPLICATION FOP, AN INDIVIDUAL SEWAGE DISPOSAL- PERMIT Name o f OWNER 1-3,19 �� �� PHONE 3J Z) 98 4 Z 73-t Z Address of OWNER,�v/TE 0600 - /ZS S. MJ40<60- 121Ve I (Jf'1CA4-0" 2"4L"' �e060�6 Name of APPLICANT J 4 L 1 � PHONE PERMIT TO BE: (JQ Picked Up. led tot '' TYPE OF PERMIT: KNev Installation ( )Repair Owner ()QApplicant ( )rmergency Use ( )Alteration NOT due to failure IACATION OF PROPOSED SYSTEM: ?� e Legal Description 5� + Z 5MoW #AA5S �Effk f2O� � Block_ riling __ SubdivisionA%NJgEN Ae'14046 size of Lot S, / acres Lot TYPE OF STRUCTURE:ASingle Family Dwelling ( )Others Do you plan any furtheryS4ditions to the residence? ( )YES yQN0 No. of bedrooms_ No. of Lofts- No. of Garbage Disposals No: of Automatic Dishwashers No. of Automatic Clothes washers WATER SUPPLY: Private well, Depth or ( )Public, Name of System j )Sprir.q ( )Stream or Creek TYPES OF INDIVIDUAL SEWAnE DISPOSAL SYSTEM PROPOSED: f:tVSeptiC Tank/Absorption Field ( )Aeration Plant/Absorption Field ( )Composting Toilet ( )Incineration Toilet ( )Mound ,( )`Recycling, potable use ( )Recycling, other use ( )Vault Privy ( )Other: The initial site inspection must be arranged with the Aspen/Pitkin Environmental Health Department (925-2020. 8:30-9:30 a.m.) before a permit can be issued. The individual sewage disposal permit must be issued before a building permit can be obtained. FINAL INSPECTION APPROVAL MUST BE GIVEN BY THE ASPEN/PITKIN ENVIRONMENTAL HEALTH DEPARTMENT PRIOR TO BACKFILLING ANY PORTION OF THE SYSTEM. Application for an individual sewage disposal permit is hereby submitted. The undersigned acknowledges that the above information is true and that false information 1 validate the application and any subsequent p= rmi Signature of Applicant DATE J (This application becomes. invalid 12 months from the above date.) NOTE: 1. PLOT PLAN must be filed with this application Please locate the following items by measured distances: 1. Property :Lines and dimensions. 2. Proposed and existing water wells on subject property and adjacent property. 3. Domestic water service lines. 4. Proposed and existing buildings, driveways, and other structures. 5. Streams, Lakes, ponds, irrigation ditches, and other water courses. 6. Proposed ,and existing individual sewage systems on subject property. SUBMIT A REVISED PLOT PLAN PRIOR TO CONSTRUCTION IF INSTALLATION IS TO BE CHANGED FROM ORIGINAL PLAN. The undersigned h�r by acknowledges receipt of this individual sewage disposal permit application andbya permitje� in the amount o! i� �_� Receipt Number , Date Fee Received ;4.1 Administrative Officer 930 SoutFi Galena Street Aspen, Colorado 81611 303/925-2020 " M WE November 22, 1988 Jay Baylin C/O Joe Zaluba Western Heritage Log Company 600 S. Original Aspen, Co. 81611 Q McLaughlin Water Engineers, Ltd. 210A Ventnor Ave., Aspen, Colorado 81611 (303) 925-1920 RE: BAYLIN SEPTIC SYSTEM; FINAL APPROVAL Dear Mr. Baylin and Mr. Zaluba: RONALD C. McLAUGHLIN HALFORD E. ERICKSON DOUGLAS T. SOVERN WILLIAM C. TAGGART ROBERT L. CARLEY WILLIAM R. KENDALL CHARLES L. HARDT RALPH L. TOREN JOHN T. McLANE GENE A. BURRELL MICHAEL E. MERCER JOHN M. PFLAUM MICHAEL R. GALUZZI RONALD E. DVORAK SCOTT E. LEHMAN KENNETH D. ZIEBART MARY ANNE BUSH On November 21, 1988 a Final Inspection of the Septic System was held at the site. Bob Nelson with the Pitkin County Environmental Health department, Don Gram with Western Heritage Log Company, and myself reviewed the system. The inspection covered all phases of the design and installation and the two previous punch. lists, dated June 22, 1988 and August 3, 1988. All items were found to be complete and the system was given Final Approval for operation by McLaughlin Water Engineers and the Pitkin County Environmental Health Department. Bob Nelson gave permission at the inspection to remove the air vents from the septic field. Don was asked to cut the vents off and add clean out caps for future inspection. The caps are to be buried below the surface and protection and locating devices installed over them. If you have any questions regarding the system and it's operation or other matters, please fell free to contact me at any time. Thank you for allowing us to work with you and I hope we can be of service to you in the future. Very Truly Yours, McLAUG/HLIN WATER ENGINEERS, LTD. an eros.ier, P. E. CC: Bob Nelson - PC EH McLaughlin Water Engineers GDD/BAYLIN FINAL APPROVAL/88-020.02 CASTLE ROCK (303) 688-5599 DENVER (303) 458-5550 LAKE DILLON (303) 468-2141 HAROLD ROBERTS JACK W. STEINMEYER LEANDER L. URMY TULSA (918) 664-2741 COMPLETE ENGINEERING SERVICES IN: WATER RIGHTS AND RESOURCES WATER TREATMENT AND DISTRIBUTION SUBSURFACE DRAINAGE IRRIGATION FOUNTAINS STORM DRAINAGE AND FLOOD CONTROL WASTEWWATFR COLLECTION, TREATMENT AND REUSE FIRE PROTECTION WATER BASED RECREATION SPECIALTY HYDRAULICS RATE STUDIES AND UTILITIES ECONOMICS ■® 4 iOd bo TABLE II r PERCOU\TION TEST RESULTS WATER DEPTH WATE't DEPTH DROP IN AVERAGE HOLE HOLE * LENGTH OF AT START AT AT END L OF INTERVAL WATER LEVEL PER`OLATIOncRATE N0. DEPTH INTERVAL OF I (Inches) (Inches) (In.) (Min.) (Inches) 1 46 43.50 42.00 1.5 60 60 42.00 40. 75 1.25 45 ,yin./Inch. 2 42 36.00 35.75 0.25 60 60 35.75 35. 60 0.15 300 Min./Inch 3 41 36.25 34.50 1.7S 60 34.50 34.00 0.5 55 Min ./inch * Holes were drilled to 5 feet then soaked. on May 13, 1986. Holes were cleaned to the depth shown for testing Cd` ti mT�0 n 1� ^'tm Op*H •;p�Cl' Nz� 0 tQ tm b 4 O mD T v a _L, D� Z I �z z .13 O H C3 .� m 4 m'*� � V o m D in Q < H i ti mT�0 n 1� ^'tm Op*H •;p�Cl' Nz� 0 tQ tm b "~ ^rn O mD T �Z O D� ti mT�0 n 1� ^'tm Op*H •;p�Cl' Nz� 0 tQ O mD �Z N,Ay Z z O H m d +� o r i ti mT�0 n 1� ^'tm Op*H •;p�Cl' Nz� 0 tQ 80x 1500 GAL SEPTIC TANK S sf'X7.S W/ACCESS'+ VENT TANK TOP OF 91•24' ERS SPLITTER ELEAVTION Of 70.W 69' 77 INVERT OUT 89 62 SEE DETAIL THIS SHEET 4� INVERTIN 88'47 V'SG M. 40 U3Lf. Y'Sc q`F ' a. VV � rvc 'll y� �LFc 00 4f'EE�O yti's(ro vs'�o �� V vo t,rrvcScN. vo ELEVDIFF ETWE N,TANK +- SPLITTER BOX AP ox. 20' vc' �«o -- 2Sl.F y" $cN•Ye /vC Gti�Ad OUT DAYL GNTz` -�-- 13 1.F.' y^ tcN. yo FNVERT INTQ HOUSE ovc 40. SI' - 'I 7 N'Ftt•i(''Cti_i; C '� ..5,... 4f.- CLEAM OUT OY.-4. z: VENir (TIP) • i / i FQ lQd lo' S82 �JG+► 1` Tse t`.` �+r"T3 7.71J fi' . t3 Y' ' SEE pETAIL THIS SHEET / {RidX - - •