Loading...
HomeMy WebLinkAboutpitkin.eh.264515400006 (2005)Pitkin County Environmental Health Department Permit for an Individual Sewage Disposal System 0405 Castle Creek Road, Suite 10, Aspen, Colorado 81611 Phone 970-920-5070 / FAX 970-920-5077 Permit # 05037 Parcel ID # 2645-154-00-006 Type of permit New( X) Repair( ) Addition/Remodel to House( ) Name of Owner Timothy Jenks Street Address 343 Monastery Cutoff Rd Property legal description Size of lot 49 Acres Water source Private well # of bedrooms in house Total square footage of the house 4320 # of offices, lofts & similar sized rooms in house Caretaker unit Total square footage of the caretaker unit # of bedrooms in caretaker unit # of offices, lofts & similar sized rooms in caretaker unit Designed for what # rooms (list) Three (3) Bedrooms Permit information Designed by Sopris Engineering Mailing Address 502 Main St, Ste A3, Carbondale Perc rate 11 Profile hole depth 3.5 Depth to groundwater or bedrock Minimum Septic tank capacity 1312 gallons Minimum Absorption area Comments 3.5 bedrock 1105 sa ft Septic permit approved per compliance with the engineer design and specifications dated 5-24-05 and Supplemental Design letter dated July 8, 2005. Any changes must be approved by this department and the design engineer prior to them being made. Minimum horizontal distances between components of the system and physical features shall conform to the Pitkin County ISDS regulations. -210&.v to -L,- 4 --la Sf 1 2 The design is based on a .95 LTAR and requires a 4666 -gallon two-compartment concrete septic tank with a duplex pump biotube vault dosing system. Effluent is pressure dosed on alternating cycles to two 50.5 ft X 11 ft sand filter absorption beds and distributed via lateral perforated pipe installed in 3 rows of 12 gravelless Quick 4 chambers per bed. The 2 ft of sand must be 2 ft or more above the bedrock. The sand must conform to the intent of Section 6.28.670 A. of the Pitkin County ISDS regulations or conform to ISDS Policy 2005-001. An invoice to document the type of sand material must be submitted. This department does not endorse any brand of products. This permit must be kept on-site during installation. The engineer must do a final inspection of the installation and submit an as -built letter to this department. This department must also be called for an inspection with a minimum of 48 hours advanced notice. "Revegetation over the area of the field is very important for the functioning of the system. Pitkin County has guidelines that must be followed to assure the plants that are introduced are appropriate for the conditions of the area. The use of native plants is strongly encouraged. Permit approved by: Date: a d� Plans and specifications of the pr sed individual sew a disposal system ha a bee reviewed and are considered satisfactory. Permission is hereby -granted to the owner or the agent to perform the work indicated in accordance with the Pitkin County ISDS Regulation in effect at the time of issue. This permit becomes invalid 6 months from the date that the permit was issued unless system construction has commenced or an extension has been approved in writing by the Department. As -built drawings must be included with this permit before the final approval will be issued. ;1/ Installer: (.Lt r inn c,,� �.�.,�n..�_ �(xr,. c a_ T 1�-- - - Final approval: YEA, IY Date: l �-'4 P. 1 COM�ICATION RESULT REPORT ( JAN. 11. 2vww 3:14PM ) FAX HEADER: ENVIRO HEALTH NAT RESOURCE TRANSMITTED/STORED : JAN.11.2007 3:09PM FILE MODE OPTION ADDRESS RESULT PAGE ---------------- -------------------------------------- 919 MEMORY TX 15409662534 OK 2/2 7040313 OK 2/2 ---------------------------------------------------------------------------------------------------- REASON FOR ERROR E-1) HANG UP OR LINE FAIL E-2) BUSY E-3) NO ANSWER E-4) NO FACSIMILE CONNECTION �I j11J,L'��a i Gita PITKIN COUNTY ENVIRONMENTAL HEALTH & NATURAL RESOURCES DATE: 1/11/2007 Send to: Timothy Jenks From: Alicia Gomez Fax Number: 540-966-2534 Phone Number: 920-5087 CC= Sopris Engineering Number OP Pages, Including Cover: 2 CC Fax Number: 704-0313 E3 URGENT p REPLY ASAP M PLEASE COMMENT C1 PLEASE REVIEW 1kfl FOR YOUR I N FORMATION COMMENTS: Septic Permit #05037 for parcel 2645-154-00-006, owner Jenks, has been finalized. Please feel free to call 920-5070 if you have any questions. fax cover Pitkin County Environmental Health and Natural Resources 040S Castle Creek Road Suite #10, Aspen, CO 81611 Phone (970) 920.5070 1 Fax (970) 920.5077 Web site www.aspenpitkin_com/ehnr PITKIN COUNTY ENVIRONMENTAL HEALTH DEPARTMENT APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM 0405 Castle Creek Road, Suite 10, Aspen Colorado 81611 Phone (970) 920-5070 Fax (970) 920-5077 Name of OWNER/ � 1- ��- 1 Owner's Mailing Address 1- C: 4 1c- r0 City,State, Zip Q, �% -J Business Phone: S C% S-3 Home Phone: SA U ` j'"O E-mail Address: 2 Ll fC m Primary Contact Person (all communication regarding this permit will go through this person) Name Company Contact Mailing Address 1 61 0 1L 0 city, tate, Zi U 1 / Q L % 7 Business Phone : -`7 `' �3 7 37S—CD Cell Phone: Fax: 5410 Z ,C--39-mail Address: Parcel ID # (available from assessor's office <</ at 920-5160 or at www.pitk:inassessor.org ---� ( J l L Street address of property 3 J ty fe s a ez v r ea f i✓ <-�- % r� Legal Description: Lot Block Filing Subdivision/1 Size of lot: C/ acres. Type of proposed structure: S i N / /L )IJ -1i t4 Total square feet of house y 3 1 Q # of bedrooms (potential) in house 3 69 e Caretaker Unit: Attached ( ) Detached ( ) Total area(sq. ft.) of caretaker unit # of bedrooms (potential) in caretaker unit Permit is for: New Home ( ) Repair due to failure ( ) Remodel/Addition ( ) Emergency use ( ) Water: Private well ( V Spring ( ) Stream ( ) Community/Public Water System( ) If community system: Name of system The fee for a ISDS application is $600 for a permit that takes 6 hours or less for the department to approve. If approval takes longer than 6 hours, a rate of $100 per hour will be charged. The maximum fee is $1000. The basic fee of $600 is due at the time of application. The remainder, if any, will be due in two stages: first, at the time of issuance of the ISDS permit; second, before final approval of the ISDS permit. C0jL7 Application for an individual sewage disposal system is hereby submitted. I hereby certify that the above information is true and accurate and that I have provided true and accurate information on locations of all existing and proposed wells, contour intervals, buildings, property lines, ditches, slopes, waterlines, springs, suction or irrigation lines, drinking water cisterns, drain tiles, irrigation ditches, lakes, water courses, streams, floodplains, dry gulches, and existing septic systems. I hereby certify that any such features not shown on attached site map are not present. Issuance of the permit does not imply the approval of any other permit required for construction pursuant to Pitkin County codes. No construction may be undertaken until all approvals and permits have been obtained. The Pitkin County Environmental Health Department, Pitkin County and employees of these agencies will be held harmless should the individual sewage disposal system fail or malfunction. The permit to construct is issued on information submitted by the applicant or his/her representatives. The owner assumes full g responsibility 'n case of failure of the system. Signature of applicant = Date Received by I� Receipt ## (I �l Dateru O� 1 G:�isdslisds appliclisdsapp Rev050103.doc v� Tim Jenks Valley Builders Custom Homes 863 Twinoak Drive Troutville, Virginia 27175 Nancy Mackenzie Pitkin County Environmental Health Department 0405 Castle Creek Road Aspen, CO 81612 December 22, 2006 VED JAN 0 `r 2001 PITKIN CUUN j ENV,HUNMENTA1 HEALTH & NATURAL RESOURCES RE: AS -BUILT, Jenks Residence, Onsite Wastewater System Design, off of Chateau Way, Shield -O -Mesa, Pitkin County, CO SE Job No. 25093.01 Permit Number: 05037 Dear Tim and Nancy: Pursuant to requirements, this letter provides documentation that the new Onsite Wastewater System (OWS) recently installed at the above referenced site is in general compliance with the permitted design. Sopris Engineering inspected the excavations and the installation of system components at various times during construction prior to final backfill. The system constructed on site was designed and built to serve the needs of a 3 - bedroom house on the lot off of Chateau Way, in the Shield -O -Mesa Subdivision. Sopris Engineering performed several visits to inspect and document the as built conditions of the constructed system. We have coordinated our efforts with the contractor that built the system. The as built conditions and installation of the new OWS components is in compliance with the permitted design specifications for the system. The System was installed in accordance with Pitkin County Regulations; the design presented in the Sopris Engineering Report and the design drawing, dated May 24, 2005. A 2000 -gallon dual compartment concrete septic tank was installed with an appropriate inlet sanitary tee and an Orenco Systems Inc., duplex pump bio -tube vault dosing assembly and associated piping and controls. The tank effluent discharges to two 50.5' x 11' partially mounded sand filter/soil absorption bed systems. The beds utilize leaching chambers over a minimum 24 -inch deep sand filter media and are pressured dosed on alternating cycles. The soil absorption system provides secondary treatment of wastewater for infiltration into the ground. The partially mounded bed absorption system is installed over the native soils and select import material. The system meets required setbacks and is installed within the general locations indicated on the attached plan. Suitable pit run type material fill was placed as needed below the sand filter to raise the level of the mounded beds to an appropriate height above the seasonal high ground water. The Sand Filter/absorption beds were installed level. Inspection ports were installed at the terminal ends of the chambers over the ball valve capped end of the 1.25" perforated distribution pipes. The average depth at the top of the sand from existing ground is approximately 3 feet. The exposed soils after grubbing were suitable and consistent across the field. An average 12 -inch layer of sandy pit run material was placed in the excavation below the sand layer. Approximately 24 inches of pit run and excavated material was placed over a portion of the west bed where the infiltrative surface appeared to be composed of fractured bedrock material. The chambers were backfilled with sand and excavated material and covered with filter. A minimum of 12 inches of backfill was placed over the chamber to the finish grades that have been shaped to provide drainage away from the beds. Appropriate grading around the down gradient side of the mound was completed with approximate side slopes at 3:1 to daylight. The pump assembly and distribution piping has been installed according to the engineered design plans. Additional observations of the soils within the field were performed during construction indicating that the soils are consistent with the description in the geotechnical report. 502 Main Street • Suite A3 • Carbondale, CO 81623 • (970) 704-0311 • Fax (970) 704-0313 SopRis ENGINEERING a LLC civil consultants William Sharman Nancy Mackenzie SE Job No. 25093.01 December 22, 2006 Page 2 OWS Operation and Maintenance The re establishment of vegetative cover over the field and responsibility for inspection and maintenance of the system will remain with the Lot Owner or the owners representative. All components of the engineered OWS shall be inspected on a regular basis and be properly maintained. The system and responsibility for repair and maintenance of the system will remain with the Owner. The OWS should require minimal maintenance. Several factors influencing the need for maintenance include: actual wastewater flows versus design flows, the volume of kitchen/domestic waste (excluding human waste and toilet paper), excessive household chemicals and other toxic liquids. The tank, absorption field and other system components should be visually inspected bi-annually for debris, damage, leaks, or other potential problems. In general, for a properly utilized system, septic tanks should be pumped and inspected every 2 - 4 years. The effluent filter should be cleaned every six months and at the time of pumping. Absorption fields should be maintained with suitable vegetative cover and kept free of root invasive plants. Positive surface drainage away from the absorption field should be maintained. If you have any question or need any additional information, please call. Sincerely, SOPRIS ENGINEERING, LLC Paul E. Rutle ge Design Engineer fthol, P.E. Engineer_ fio" 07/08/2005 15:11 970-704-0313 SDPRIS ENGINEERING PAGE 02 July 8, 2005 Nancy Mackenzie Pitkin County Environmental Health Department 0405 Castle Creek Road, Suite 10 Aspen, CO 81612 RE: Supplemental Design Information, Jenks Residence, Onsite Wastewater System Design, off of Chateau Way, Shield -0 -Mesa, Pitkin County, CO SE Job No. 25093.0.1 Dear Nancy: Pursuant to your verbal request and your transmittal dated June 15, 2005, this letter provides supplemental information in regard to the proposed OWS at the above referenced site. In regard to the septic tank size we can install a 2000 -gallon tank that will provide approximately 638 gallons of excess storage capacity. The current design calls for a 1500 -gallon tank that will provide approximately 188 gallons of excess storage capacity based on the requited detention volume per deign flow. The standard rule of thumb for upsizing tank capacity when utilizing a pump system is to increase the tank capacity by one size, assuming 250 - gallon standard capacity increments. The design calls for the pump floats to be set to provide 3" of draw down that equates to approximately 75 gallons. Therefore approximately 113 gallons of excess capacity is maintained over the required 1312 gallons calculated for detention time in a 1500 -gallon tank. The dosing volume is slightly less since there is a lag effect of draw down levels in the tank chambers and the pump basin. This effect results in the lowest liquid level occurring :in the pump vault and the off float being tripped. We believe that the size of the tank is adequate to provide effective detention of the effluent however I informed the owner that the tank will need to be upsized to 2000 gallons since a 1750 -gallon tank is not available. Pursuant to this letter the design will include a 2000 -gallon tank or as an alternative we will install a separate pump vault. If your feel the larger tank is necessary please include the aforementioned alternatives in the permit or allow the 1500 gallon tank if your comfortable with my analysis. We will install in accordance with the conditions indicated on the permit. Attached is the recent geotechnical report for your review with the results of the percolation tests. The test results and observations are consistent with previous information and our assumptions. The results do not indicate that any design modifications need to be made. I performed a site visit today to inspect the staked out location of the field. The fields are to be located further up gradient toward the house and are staked out over more consistent grades that will not exceed general design standards. The fields will be within the building and septic envelopes. If you have any question or need any additional information. please call. Sincerely, SOPRIS ENGINEERING, LLC P ul E. Rutledg Design Engineer Cc; Tim Jenks RECEIVED JUL 0 8 2005 PITKIN COUNTY ENVIRONMENTAL HEALTH 502 Main Street • Suite A3 • Carbondale, CO 81623 • (970) 704-0311 • Fax (970) 704-0313 SOPRIs ENGINEERING • LLC civil Conui consultants Tim Jenks Valley Builders Custom Homes 863 Twinoak Drive Troutville, Virginia 27175 RE: Jenks Residence, Onsite Pitkin County, CO SE Job No. 25093.01 Dear Tim: MAY 2 4 ?m PITKIN CO?iAT" ENVIRONMENTAL SEXILI RECE VEE Iti May 24, 2005 PRKir Wastewater System Design, off of Chateau Way, Shield -O -Mesa, Pursuant to your request, this letter presents our findings in regard to the feasibility of design and approval of an engineered Onsite Wastewater System (OWS) for the above referenced Site. This design is based on our evaluation of the site conditions with information provided by others for use in supporting your application to Pitkin County. Our recommendations are in accordance with Pitkin County and the State of Colorado ISDS Regulations. Pitkin County must permit any proposed improvement to the site. We have reviewed the information forwarded to us, conducted a site visit, formulated an OWS design and created a site plan with construction details as part of our scope of work. Conclusions Based on our findings we believe that the design and installation of an improved OWS system is feasible in accordance with Pitkin County Regulations and the State of Colorado. The system will serve the needs of a 3 -bedroom single-family home. Our design recommendations for an OWS include the installation of a 1500 -gallon concrete septic tank equipped with a duplex pump biotube vault dosing assembly and associated piping and controls. The treated effluent will discharge to two 50.5' x 11' partially mounded sand filter/soil absorption bed systems. The beds will utilize leaching chamber and will be pressured dosed on alternating cycles. The soil absorption system will provide secondary treatment of wastewater for infiltration into the ground. The partially mounded bed absorption system can be installed over the native soils and select import material. The system will meet all required setbacks and be installed within the general boundaries indicated on the plan. Our design is outlined below and delineated on the attached site plan. Site Location The subject site is located off Chateau Way, in Shield -O -Mesa, in Pitkin County, Colorado. The site is situated in Section 15, T 9 S, R 86 W of the 6`h P.M. The Site comprises approximately 57.7 acres. The site is bounded by undeveloped mountainous rangelands with scattered single-family acreages. Existing Site Conditions The site is located near the crest of a southeast trending ridge near the top of Shield -O -Mesa. The building envelope is on a relatively flat area moderately sloping to the southeast. The existing ground surface in 502 Main Street • Suite A3 • Carbondale, CO 81623 (970) 704-0311 • Fax (970) 704-0313 SosENGINEERINGPRI• LL civil consultants C Tim Jenks SE Job No. 25093.01 May 24, 2005 Page 2 the proposed septic development area ranges from 8% to 15%. An exiting gravel driveway provides access into the building envelope. The rest of the undeveloped site has limited vegetation consisting of sparse clumps of grass, weeds, scattered scrub oak and sagebrush. Proposed Site Conditions It is our understanding that you intend to construct a new home with an attached garage to serve the needs of a 3 -bedroom home. The proposed structure has a basement space that does not including any plumbing or drain lines. The proposed improvements will include a new partially mounded absorption field and septic tank with a pump dosing assembly. The proposed field location, grades and site conditions will be further evaluated during construction to confirm assumptions made in the following design recommendations. The new facilities are to be generally located as shown on the plan. Subsurface Conditions Attached herewith are the results of the subsurface investigation and percolation tests conducted on April 8, 2005 by Hepworth-Pawlak Geotechnical, Inc. The report is dated April 21, 2005. The subsoil encountered at the site consists of/z to 1 foot of topsoil overlying 1-3 1/z feet of gravel and cobble size shale fragments in a sandy clay matrix overlying claystone bedrock. The profile Pits were excavated to backhoe refusal depths of 21/2 to41/2 feet. Groundwater was not encountered in the pits. Percolation testing has not been preformed due to winter condition during the soil evaluation. Based on the soil analysis and observation in the field we are assuming a loading rate for treated effluent to be between 0.4 and 0.6 gallons per square foot per day. itional geotechnical evaluations and inspections by the engineers will be performed prior to and during initial stages of construction to verify assumptions ma a or a WS designf-- The evaluations and inspections may result in modifications to the design that may include field size revisions and possible soil replacement in select areas if needed. Design Criteria The proposed residence will be a 3 -bedroom house. The design flow is calculated as follows: The new OWS shall be based on a minimum of 3 -bedrooms assuming a dwelling area of approximately 3600 S.F. Residence unit - 3 bedrooms @ 2 person /bedroom = 6 person From the Pitkin County I. S. D. S. Regulation: Max. Design flow (Qd) _ # of people x 100(avg. flow gal/person/day) x 1.75 = gal/day Gallons per day for the subjeet house = 100 gal/person/day for 2000-6000 S.F. dwelling space. Qd = 6*100*1.75 =1050 a� 1/day Septic Tank Design Tim Jenks SE Job No. 25093.01 May 24, 2005 Page 3 Per regulations Qd = 1050alg /daY Volume (V) of tank = Design Flow * 1.25 (30 hour retention time) V = 1050 gal/day * 1.25 — 1312 4Vp is t Use one 1500 -gallon seank Use a double chamber concrete tank with a filtered dosing pump system and controls. The tank must have appropriate access openings with watertight risers and lids. The septic tank, risers and sewage lines must be watertight. Mounded Absorption Field Design A site plan is provided to detail the various components of the proposed sewage disposal system. The location of the proposed absorption field system is down gradient of the proposed structure. A partially mounded system needs to be built high enough to so that the treatment sand is above the native soil infiltrative surface. We have designed the mound with the top approximately 1.5 feet above the existing sloped grade on the up -gradient side of the beds. The bottom of the sand layer should be approximately 2 feet or more above the bedrock. The following information details the technical criteria utilized in design of a proposed system. Proposed Absorption System Area required for treatment bed in mound system: Long Term Acceptance Rate method (LTAR) Using imported course sand media yields the minimum area: LTAR maximum loading rate for 24" deep sand filter = 0.95gal/S.F./day A=Q/LTAR = 1050/0.95 = 1105 sq. ft. We recommend the use of two equally sized sand filter absorption beds utilizing pressure dosed leaching chamber installed in a typical mounded bed configuration over the top of the sand layer. We recommend the installation72 uick-4 Infiltrator chambers in two beds with 3 rows of 12 chamber units each. Use: Minimum two 50.5'x 11' partially mounded sand/filter absorption beds underlying pressure dosed leaching chambers. The total perimeter area of placed sand in the partially mounded field is approximately 1900 S.F. The chambers in each trench shall be installed at level grade. The bottom elevation of each trench may vary to achieve a maximum depth of 36" inches to the trench bottom surface below the proposed grade. Tim Jenks SE Job No. 25093.01 May 24, 2005 Page 4 The grade below the sand layer shall be filled level with suitable excavated material or 3" minus sandy pit run material. Install with minimum 10" cover over top of chambers. Inspection ports shall be installed at the terminal ends of the chambers over the ball valve capped end of the 1.25" perforated distribution pipes. The vertical inspection ports shall be 4" SDR 35 or schedule 40 pipes extending at least 6" above the surface. This will allow for checking the performance of the system and distribution pipe maintenance. The mound needs to be graded to prevent surface water runoff from collecting on or around the mound. Effluent Dosing Distribution System The effluent from the septic tank will be pressured dosed to the field by an alternating duplex pump system installed in the secondary compartment of the septic tank. A septic tank effluent will be pumped through dual 1.5" transport line from the discharge assemblies to the distribution manifold header at the head of each bed and be distributed through the individual 1.25" pressurized distribution laterals. The 1.25" pressurized distribution laterals will be installed on the top of the sand layer and run the full length of the chamber rows. We recommend the use of an Orenco Systems BioTube pump vault system. The pump system shall incorporate a duplex pump system to insure continuous operation and alternate dosing between the beds. The controls shall provide for alternate operation of each pump. Automatic float switches including a high water float with alarm shall be incorporated in the system. The pump assembly and dosing chamber will be installed in the secondary compartment of the septic tank. The vault will utilize a maintainable effluent filter. The effluent pumps are sized to pump at a minimum velocity of 4 ft/sec at approximately 47 gpm. The dosing volume will be approximately 75 gallons. Install pumps assemblies, risers, electrical systems, floats and discharge line per manufactures installation guidelines. Use an Orenco systems pump model P5005-12dax2. The system shall be inspected by a qualified technician after installation. An Orenco systems pump control panel shall be installed by a qualified installer in coordination with the electrician. We recommend 230 volt electric service be provided to the pumps. The power supply for the pumps and controls shall consist of (2) 20 amp circuits for the pumps and (1) 10 -amp circuit for controls. Provide line of site disconnect with control box. The electrician or qualified installer shall install electrical wires in conduit from the control panel to the pump assembly junction box in the riser over the pump basin. All installation and maintenance shall be performed by a qualified person in accordance with the installation & maintenance guidelines for the Orenco systems bio -tube vault pump assembly. The transport line from the dosing pump to the absorption field shall be schedule 40 PVC with a maximum diameter of 1.5 inches. The transport line will be installed with a minimum 2% slope to insure complete drainage into the beds. The perforated pipe will have 3/16" orifices oriented upward to spray against the interior of the chambers. Two 3/16'' drain orifices oriented downward will be installed over splash plates or orifice shields. A 4" inspection port will be installed on the end chambers over the ball valve capped ends of the distribution laterals. E Tim Jenks SE Job No. 25093.01 May 24, 2005 Page 5 OWS Operation and Maintenance All components of the engineered OWS shall be inspected on a regular basis and be properly maintained. The system and responsibility for repair and maintenance of the system will remain with the Owner. The OWS should require minimal maintenance. Several factors influencing the need for maintenance include: actual wastewater flows versus design flows, the volume of kitchen/domestic waste (excluding human waste and toilet paper), excessive household chemicals and other toxic liquids. The tank, absorption field and other system components should be visually inspected bi-annually for debris, damage, leaks, or other potential problems. In general, for a properly utilized system, septic tanks should be pumped and inspected every 2 - 4 years. The effluent filters should be cleaned every six months and at the time of pumping. Absorption fields should be maintained with suitable cover and kept free of root invasive plants. Positive surface drainage away from the absorption field should be maintained. Construction and Inspections Prior to construction of the permitted system the engineer should be contacted by the contractor and owner well in advance to provide adequate time to discuss the system components with the contractor, answer questions, resolve any conflict issues and schedule inspection site visits based on construction progress. County Regulations require that the Design Engineers of record perform site inspections of the permitted system during construction and provide "As -Built" documentation of the installed system to the County after construction is complete. The Regulations further require site inspections and approval by the County Environmental Health Department of the exposed components of the system prior to backfilling. Therefore the County Environmental Health Department should also be contacted and notified of the construction schedule. General Notes 1) All materials and installation practices shall conform to Pitkin County and the State of Colorado Individual Sewage Disposal Regulations. 2) All sewer lines and distribution lines in the system shall be 4" Schedule 40 or SDR -35 PVC unless specified otherwise on the plans. 3) Add a two-way clean out on the service line from the proposed house addition. 4) The contractor shall ensure that the concrete septic tank, risers and sewer lines are watertight. 5) The mounded bed area must be protected to prevent damage from vehicular or livestock traffic and must be crowned to divert drainage runoff away from the bed. 6) A pressurized distribution manifold header pipe shall be installed at the head of the field to insure equal distribution to individual 4" perforated distribution laterals. 7) The treatment sand shall be clean concrete sand with an effective size in the range of 0.25 mm and 0.75 mm is recommended, with a CU of 5.0 or less. 8) The infiltration chambers shall be installed level in each bed. The top of the backfill over the chambers shall be covered with filter fabric to prevent the migration of fines from the overlying topsoil layer. We recommend that sand be used to backfill the chambers to the top of the louvers. E40 Tim Jenks SE Job No. 25093.01 May 24, 2005 Page 6 9) A final cover of soil suitable for vegetation, a minimum 4" deep, shall be placed to the finished surface grade. The mound shall be planted or seeded with mulch for suitable vegetative cover. 10) Fill utilized in constructing the mound and or bed base must be clean suitable 3 inch minus sandy pit run or suitable native material. Fill materials to be approved by the engineer. Our design and recommendations are based upon data supplied to us by others. If subsurface or site conditions are found to be different from those presented in this report, we should be notified to evaluate the effect it may have on the proposed ISDS. If the County Environmental Health Department requests changes or modifications to this design, we should be contacted to evaluate the effect on the ISDS. If you have any question or need any additional information, please call. Sincerely, SOPRIS ENGINEERING, LLC ezoov 'Z� Paul E. Rutledge I I � y W � z o N z c� ¢ o Q w W L.LI ZO w W • = Q s _� v W M S uQ'-� d Jc ca C U v n O o W w v V U v I I a aN C� (D •` � la � r cn o 0 I ��r d I LU N zi z! IA I ITIT I I 0 LOP 40, �L�o / 1 1Id CD V N O vW Cp � 1991'(H(31) peaH OiweuAa P101. W co co co U O N Q) C w C w C C C C.2 0 0 0 M O N 0 IT = 0 0 0 0 0 0 OV N = 0 '> r N r Z r r N BOG r r 0 0 a6 t (JNn a (Nn OQ) UN N NN UQC(na aJ cJ °0 0 > ZJ N Cn 0 co a, C O J U iO w m a ° a a v m O [L N ti CIO '• C Q (O I. •U a O J J (� C �^ U J C (� Q LL 4) = o a a a o _ L o M o Q E ° o A2 ucn Z ccn s � � "s 3 L N 0 r - 0 to a 0 T v � tm L v 0 h co O N O CL CL E rt+ CA 01 o w w w YO•. w0- a0- Q af0O CO r O O N O r W W O O cm 0 w G N O CV r O C C N 6 G C Co Lo LD � N 0 3 0 cca O R G te � a° a y in J c t a �' _o c � H N O) C-11 O J O J y C C �- w O C a m y O) L ,�•• lO a J J v5 g C L O O u. O Q p a O a L L o o m 2 aoi o> Tw c~n ~ -oO i6 E E= o= o N Q O E c EZ = m J H c Z U) = N N i g _ _ s 3o 0 j ll co PI transmittal To: Nancy MacKenzie Company: Pitkin County Environmental Health 0405 Castle Creek Rd., Ste. 10 Aspen, CO 81611 From: Paul Rutledge Date: Subject: SE Job No.: 05/19/05 _Jenks Residence 25093.01 Pickup 1 No. of copies Item Remarks 1 OWS Site Plan and System Details 0 1 Letter to Tim Jenks Dated May 19, 2005 Pickup 1 HP Geotech Report 0 Federal Express If materials received are not listed above, please notify us. Transmitted by: 0 First Class Mail 0 Express Mail 0 Messenger 0 Pickup 0 U.P.S. 0 Federal Express 502 main street • suite A3 carbondale, CO 81623 ❑ (970) 704-0311 0313 SOPRIS ENGINEERING • LLC RECEIVED MAY Ct�E�S PITKIN COUNTY ENVIRONMENTAL HEALTH fax (970) 704 - civil consultants Page 1 of 2 Nancy Mackenzie From: Paul Rutledge [paulr@sop risen g. co m] Sent: Thursday, January 11, 2007 1:42 PM To: Nancy Mackenzie Subject: RE: Jenks 343 Monastery Cutoff Rd The contractor is Wilson Custom Homes. The project manager is Troy Wilson (319 8410). He was in charge of installation and construction of the system and my only contact. My counter splash board is supposed to be installed today. Were close to completion of this phase of remodel. We took 2 steps backward last week with the unforeseen break in an old pressure assembly bladder that caused the flooding of our downstairs. Had to extract water and dry the walls through an insurance claim. Stored furniture and previously stored items where I could. Everything is dry now. House work never seems to end, I will continue my efforts forever. Very cute puppy! From: Nancy Mackenzie [mailto:nancym@co.pitkin.co.us] Sent: Monday, January 08, 2007 8:54 AM To: paulr@sopriseng.com Subject: Jenks 343 Monastery Cutoff Rd Happy New Year! I hope your kitchen is back in working condition for the new year! I received your as -built and am ready to sign -off on the final Who installed the system? I don't have that in my notes. Nancy Nancy MacKenzie 970-920-5076 1 /110007 Pitkin County Environmental Health Department Contact Log Sheet paulr@sopriseng.com, 02:10 PM 6/15/2005, Tim Jenks project, 330 Monestry Cut -Off Rd To: "paulr@sopriseng.com" <paulr@sopriseng.com> From: Nancy MacKenzie <nancym@co.pitkin.co.us> Subject: Tim Jenks project, 330 Monestry Cut -Off Rd Cc: DeputyELKXX@cs.com Bcc: Attached: To: Paul Rutledge, Sopris Engineering Paul, I want to reconfirm our phone conversations on May 26th and June 13th and the outcome of our site visit to this property on May 31. We discussed that a larger septic tank is required because the dosing duplex pump replaces some of the tank capacity and there must be additional capacity for the dosing when there is not a separate dosing tank. I will need a letter from you indicating this change. In addition, the application was incomplete because it did not include percolation test information. was told that HPhad been contacted to do this. I have not received this information. It appeared to me that the soil would pLr& okay, but our regulations do require 3 soil percolation tests in the area where the absorption system is to be located. (Article 5: Soil Tests, 6.26.310). The system design is for 2 ft of sand and we need to be assured that there is a total of 4 feet of suitable soil to treat the effluent. Because of the varying slopes and the small area for the house and septic components, I required that the location of the house and septic beds (primarily the north bed) be staked to assure the setback from the house could be met and that the beds could be positioned in the best areas due to the slopes. After receiving the percolation soil data, you and I were to go to the site to review the staking and determine the final location of the beds. At that, if everything is fine, I will be able to issue the septic permit. Nancy cc: Tim Jim Austin, Building Dept Printed for Nancy MacKenzie <nancym@co.pitIdn.co.us> Carla Block, 02:34 PM 6/8/2006 jenks X -Sender: carlab@commons X -Mailer: QUALCOMM Windows Eudora Pro Version 4.2.0.58 Date: Wed, 08 Jun 2005 14:34:43 -0600 To: nancy MacKenzie <nancym@ci.aspen.co.us> From: Carla Block <carlab@ci.aspen.co.us> Subject: jenks X-MailScanner-Information: Please contact the ISP for more information X-MailScanner: Found to be clean Page 1 of 1 OK, after discussions with both Paul and Tim, I said we could not release his permit until he had soil testing done and he also staked the area of the field, per your request. Since they had people waiting on site with equipment, I was wondering if there was a way to issue the foundation permit. My conversation with Tim was that he had 2 options, either to wait for you to get back (monday) or to try to get a foundation permit which would allow him to get started, but may cost quite a bit more. The last message from Jim was that he had talked to Tim and was going to simply release the whole permit, but with BIG, BOLD letters say that all EH issues need to be addressed within 1 month (July 8). That is what I understood. Now, I confused and extremely busy, so I'm not sure if this is a battle I need to fight or not. Can you take care of this when you get back? If there is a MAJOR reason that they should not have their building permit (aside from the fact that this is not how the process works) - like there is not enough room on the property, etc... call Jim right away. Sorry to leave you with that mess, but I was unclear talking to Paul with his understanding and then reading your notes - I couldn't put it all together. welcome back!! cb Carla Block, REHS Pitkin County Environmental Health and Natural Resources 970-920-5438 Printed for Nancy MacKenzie <nancym(aco.pitkin.co.us> 6/13/2005 Ob Carla Block, 09:50 AM 4/11/2005 , Re: septic issues X -Sender: carlab@commons X -Mailer: QUALCOMM Windows Eudora Pro Version 4.2.0.58 Date: Mon, 11 Apr 2005 09:50:57 -0600 To: Nancy MacKenzie <nancym@ci.aspen.co.us> From: Carla Block <carlab@ci.aspen.co.us> Subject: Re: septic issues Cc: Jim Austin <jima@ci.aspen.co.us> X-MailScanner-Information: Please contact the ISP for more information X-MMailScanner: Found to be clean 1 spoke with Mr. Jenks on the phone Friday and described the process. FYI. cb At 08: RE: Jenks, 343 Monastery Cutoff Wallison, 1880 Lazy O Marolt, Lower Bullwinkle Page 1 of 1 Wallison has not submitted for a septic permit as yet, probably waiting on the weather to do soil testing. Marolt - still figuring this one out with the engineer Jenks - they haven't ever contacted us as far as I know Nancy Nancy MacKenzie Pitkin County Environmental Health Senior Environmental Health Specialist 0405 Castle Ck Rd, Suite 10 Aspen, CO 81611 970-920-5076 970-920-5077 fax nancym@ci.aspen.co.us Carla Block Pitkin County Environmental Health 970-920-5438 Printed for Nancy MacKenzie <nancym@co.pitkin.co.us> 6/2/2005 PITKIN E,NVIRO1,MENTAL HEALTH DEPARTM] ISDS DESIGN CALCULATIONS Owner's Name jenks Parcel ID # House Size (sq. ft.) (75 gpd, 100 gpd, or 130 gpd) Number of Bedrooms in Main House Number of Offices, Libraries, Studies, Similar -sized Rooms in Main House Number of Bedrooms in Detached Caretaker unit Number of Offices, Studies, Similar -sized Rooms in Caretaker Unit (If the caretaker unit is ATTACHED, treat as if part of main house.) Average Daily Waste Flow 600 State Review Required'? no Perc Rate (T) Design Flow (Q) = # potential bedrooms X 2 people/ bedroom X gpd X 1.75 Q= 1050 Minimum tank capacity 1312.5 gallons Absorption Area (=Q/ 5 X SQRT pert rate) A = 1105 sq. ft. of absorption area required 71 gravelless chamber units without reduction # of Perc Holes Required: 3 1 in every soil type? Spaced uniformly over QUICK 4 9_8 A = 552.5 sq.ft. with 50% reductionTRENCHES 50 gravelless chamber units with reduction STANDARD A = 552.5 sq.ft. with 50% reductionTRENCHES 36 gravelless chamber units with reduction EQ 35 EQ36 units in TRENCHES SETBACK FROM WELL # of feet = 104 SETBACK FROM POND, STREAM OR IRRIGATION DITCH # of feet = 54 SETBACK FROM DRY GULCH # of feet = 29 area? QUICK 4 9.2 773.5 sq ft 30% reduction BED 84 chamber units with reduc. 773.5 sq ft 30% reduction BED 30 chamber units with reduc. r EQ36 units in a BED 07/08/2005 15:11 970-704-0313 1-4 fn (34i§6 tech HEPWORTH - PAWLAK GEOTECHNICAL June 30, 2005 SOPRIS ENGINEERING 0 He,pworch•T`iw1--4L C1oa1Lcchnical. Inc. 5020(:(11111ry 16INLi 154 C'knwnncl "irrings, Colorado 81601 Phrnitr 970-445-7088 Fax: 970-9,11-8454 rmailh�,!_�n(!7�hpl;NUChCtt.i:.inll PAGE 03 = 6 EIVED JUL 0 8 2005 Valley Builders Custom Homes Attn: Tim Jenks �'s i KM COUNTY ENVIRONMENTAL HEALTH 863 Twinoak Drive Troutville, Virginia 27175 Job No. 105 299 Subject: Observation of Excavation and Percolation Testing, Proposed. Residence, Off of Chateau Way, Shield -O -Mesa, Pitkin County, Colorado. Dear Mr. Jenks: As requested by, Hepworth - Pawlak Gcotecluiical, Inc., observed the excavation and performed percolation testing at the subject site on June 30, 2005 to evaluate the materials exposed for foundation support acid septic disposal design. We previously conducted a subsoil study for design of foundations at the site and presented our findings in a report dated April 21, 2005, Job No. 105 299. The proposed residence will be a two story wood frame structure over a partial walkout basement level and crawlspace. The attached garage and basement floors will be slab -on - grade. Spread footings sized for an allowable bearing pressure of 2,000 psf were recommended in the previous report for building support. At the titre of our visit to the site, the foundation excavation was in progress and had been cut in four levels from 3 to 9'/z feet below the adjacent ground surface. The materials exposed in the bottom of the excavation consisted of gravel acid cobbles in a sandy clay matrix (Weathered claystone/shale bedrock) in the shallower cuts and hard claystone/shale in the deeper cuts. The upper soils and rocks were loose and disturbed from the excavating equipment. In addition, there were some roots and organic soils in the northeast portion of the excavation. We recommended via telephone that the loose disturbed soils and rock, roots and organics be removed prior to forming footings and placing concrete. No free water was encountered in the excavation and the soils and bedrock materials were slightly moist. The conditions exposed in the excavation arc consistent with those previously encountered on the site and suitable For support of spread footings designed for the recommended allowable bearing pressure of 2,000 psF. Other recommendations presented in our previous report which arc applicable should also be observed. Three percolation test holes had been hand dug and snaked by the client prior to our wrival on site. The percolation test boles were located in the area. of the previous profile pit excavated downbil) to the east of the residence at the locations shown on Figure 1. Parker 303-841.-7119 0 Coloradn Springs 719-633-5562 & Silverthorne 970.468-1939 07/08/2005 15:11 970-704-0313 Valley Builders Custom Homes June 30., 2005 Page 2 SOPRIS ENGINEERING PAGE 04 0 Percolation testing was conducted on October 30, 2005, by a representative ofFlepworth - Pawlak Geotechnical, Inc. The percolation test results are summarized on Table 1. The Percolation test results indicate an infiltration rate between 6 and 16 minutes per inch with an average of 6 minutes per inch. The soils exposed in the hest holes consisted of 3 to 4 inches of topsoil overlying gravel and cobbles in a sandy clay matrix (weathered claystone/shale). The soils exposed in the Profile Pit previously excavated, consisted of about 3 feet of gravel and cobbles in a sandy clay matrix overlying hard claystone/shale bedrock to the refusal depth of 3'/, feet. Duc to the shallow bedrock in the area, a professional civil engineer should design the septic disposal system. If you have any questions or need further assistance, please call our office. Sincerely, HEPWORTH - PAWI.AK GEOTEC `AI., INC. 4 RFC/sl �,0.•ip.N Abq,� . F C SD Jordy Z. Adamson, Jr., P. ,� 29707 n Rev. by: DEM �.��A,••.......... ••'_\b JZA/ksw attachments Figure 1 — Location of Percolation Test Holes Table 1 — Percolation Test Results cc: Sopris Engineering — Attn: Paul Rutledge Job No. 105 299 GeUPOcCh 07/06/2005 15:11 970-704-0313 SOPRIS ENGINEERING PAGE 05 150 l?ECEIVEI 150 2005 PilENVIRONMEN � L NALTH ■ PIT 3 140 1 130 120 1 I 1401 I —'1 DRIVEWAY I � 1 ' 1 130 l 110 1 I 120 I PIT 2 1 ■ �\ PROPOSED \ I RESIDENCE / � \ / � P3 100� 0 BUILDING ENVELOPE i I PIT 7 PROFILE \ PIT P2 / P2 / �- P1 Ile ISDS !-1 EASEMENT APPROXIMATE SCALE �� \ I- 50' � \ I 105 299 I HEPWORTH—PAWLAK I LOCATION OF EXPLORATORY PITS Figure 1 GEOTECHNICAL, INC. 07/08/2005 15:11 970-704-0313 SOPRIS ENGINEERING PACE 06 HEPWORTH-PAWLAK GEOTECHNICAL, INC. TABLE 1 PERCOLATION TEST RESULTS --ECEIVED J! if ' 8 2005 I I KIN COUNTY eONMENTAL HEALTH JOB NO. 105 299 HOLE N0, HOLE DEPTH (INCHES) LENGTH OF INTERVAL (MIN) WATER WATER DEPTH AT DEPTH AT START OF END OF INTERVAL INTERVAL INCHES INCHES DROP IN WATER LEVEL (INCHES) AVERAGE PERCOLATION RATE (MIN./INCH) P-1 Bi/z 2 Water added 3% 3'/4 '/2 6 31/4 23/4 1/2 ZV4 21/4 1/2- 2'/4 13/4 1/2 13/4 11/4 1/2 23A 2'/4 1/2 2'/4 2 'A 2 13/4 1 '/4 13/4 1'/2 '/4 11/. 11/4 1/4 P-2 7 2 Water added 21/e 2 1/8 i l 2 17% '/8 17/9 13/4 1/8 13/4 15/8 '/a 15/8 13% 1/4 13/a 1'/e 1/4 21/4 2 1i4 2 i7/e '/8 1 7/a 13/4 1/8 13/4 15/e 1/8 P-3 91/2 2 43/a 41/a 1/4 16 4'/a 4 '/a 4 37/e '/8 37/e 35/a 1/4 35/b 31/2 1/8 31/2 33/h 1/8 33/a 31/4 1/0 31/4 3'/4 1/8 3'/4 3 '/9 3 27/a 1/8 Note: Percolation test holes had been dug from the ground surface and soaked by the client prior to our testing. Percolation tests were conducted on June 30, 2005. The average percolation rates were based on the last six readings of each test. i 3� 07/08/2005 15:11 970-704-0313 SOPRIS ENGINEERING PAGE 01 FAX Transmittal TO: Nancy Mackenzie Company: Pitkin County Environmental Health Fax#: 920 5077 Date: July 8, 2005 Total Pages: 3 SE Proloct No. 25093.01 From: Paul Rutledge Message: Jenks Residence Supplemental OWS Information letter. Thank you for your attention to this project. o Original not to follow o Original to follow by mail 0 Original to be delivered by messenger o Original to be picked up RECEI�D JUL 0 8 2005 EIV �►RONP"rKMFN A� N -y H 502 main street • suite A3 • carbondale, CO 81623 • (970) 704-0311 fax (970) 704-0313 Sepals ENGINEERING • LLC . civil consultants Geon—**Xtect- I HEPWORTH-PAWLAK GEOTECHNICAL April 21, 2005 40ep, rlh-Pawlak Geotechnical, Inc. 5020 County Road 154 Glenwood Springs, Colorado 81601 Phone: 970-945-7988 Fax: 970-945-8454 email: hpgeo@hpgeotech.com Valley Builders Custom Homes Attn: Tim Jenks 863 Twinoak Drive Troutville, Virginia 27175 Job No. 105 299 Subject: Subsoil Study for Foundation Design, Proposed Residence, Off of Chateau Way, Shield -O -Mesa, Pitkin County, Colorado. Dear Mr. Jenks: As requested, Hepworth-Pawlak Geotechnical, Inc. performed a subsoil study for design of foundations at the subject site. The study was conducted in accordance with our agreement for geotechnical engineering services to you dated April 7, 2005. The data obtained and our recommendations based on the proposed construction and subsurface conditions encountered are presented in this report. Evaluation of potential geologic hazard impacts to the site are beyond the scope of this study. Proposed Construction: The proposed residence will be a two story wood frame structure over a partial basement level and crawlspace located on the site as shown on Figure 1. The attached garage and basement floors will be slab -on -grade. Cut depths are expected to range between about 4 to 8 feet. Foundation loadings for this type of construction are assumed to be relatively light and typical of the proposed type of construction. If building conditions or foundation loadings are significantly different from those described above, we should be notified to re-evaluate the recommendations presented in this report. Site Conditions: The site is located near the crest of a southeast trending ridge near the top of Shield -O -Mesa. The site was vacant at the time of our field exploration. A graveled driveway provides access into the building area. The ground surface in the building area is relatively flat with a moderate slope down to the southeast at a grade of about 8%. There is about 6 feet of elevation difference across the proposed building area. The terrain becomes steep on the flanks of the ridge with slopes down to the southwest and northeast at grades of about 30%. There is no vegetation in the proposed building area. Vegetation on the slopes consists of scruboak, sagebrush, grass and weeds. Subsurface Conditions: The subsurface conditions at the site were evaluated by excavating three exploratory pits and a profile pit at the approximate locations shown on Figure 1. The logs of the pits are presented on Figure 2. The subsoils encountered, below about %Z to 1 foot of topsoil, generally consist of about 1 to 3% feet of medium dense, gravel to cobble size shale fragments in a sandy clay matrix overlying hard claystone- Parker 303-841-7119 0 Colorado Springs 719-633-5562 • Silverthome 970-468-1989 -2- shale bedrock to the backhoe refusal depths of 21/z to 41/2 feet. Results of a gradation analysis performed on a sample of clayey gravel (minus 6 inch fraction) obtained from the site are presented on Figure 3. Atterberg limits testing indicates the clay matrix soils have low plasticity. No free water was observed in the pits at the time of excavation and the soils were slightly moist to moist. The bedrock was slightly moist. Foundation Recommendations: Considering the subsurface conditions encountered in the exploratory pits and the nature of the proposed construction, we recommend spread footings placed on the undisturbed natural soil or bedrock materials designed for an allowable bearing pressure of 2,000 psf for support of the proposed residence. Footings should be a minimum width of 16 inches for continuous walls and 2 feet for columns. Loose disturbed soils and rock encountered at the foundation bearing level within the excavation should be removed and the footing bearing level extended down to the undisturbed natural soils or bedrock materials. The cuts could encounter very hard bedrock and require rock excavation techniques, such as blasting, chipping and splitting. Exterior footings should be provided with adequate cover above their bearing elevations for frost protection. Placement of footings at least 42 inches below the exterior grade is typically used in this area. Continuous foundation walls should be reinforced top and bottom to span local anomalies such as by assuming an unsupported length of at least 12 feet. Foundation walls acting as retaining structures should be designed to resist a lateral earth pressure based on an equivalent fluid unit weight of at least 50 pcf for the on-site soil as backfill, excluding topsoil and oversized rock. A sliding coefficient of 0.40 and a passive earth pressure of 350 pcf, equivalent fluid unit weight for compacted backfill, can be used to resist lateral loads on the foundation. Floor Slabs: The natural on-site soils and bedrock, exclusive of topsoil, are suitable to support lightly loaded slab -on -grade construction. To reduce the effects of some differential movement, floor slabs should be separated from all bearing walls and columns with expansion joints which allow unrestrained vertical movement. Floor slab control joints should be used to reduce damage due to shrinkage cracking. The requirements for joint spacing and slab reinforcement should be established by the designer based on experience and the intended slab use. A minimum 4 inch layer of free - draining gravel should be placed beneath basement level slabs to facilitate drainage. This material should consist of minus 2 inch aggregate with less than 50% passing the No. 4 sieve and less than 2% passing the No. 200 sieve. All fill materials for support of floor slabs should be compacted to at least 95% of maximum standard Proctor density at a moisture content near optimum. Required fill can consist of the on-site soils devoid of vegetation, topsoil and oversized rock. Underdrain System: Although free water was not encountered during our exploration, it has been our experience in the area and where bedrock is shallow that local perched groundwater can develop during times of heavy precipitation or seasonal runoff. Frozen ground during spring runoff can create a perched condition. We recommend below -grade construction, such as retaining walls, crawlspace and basement areas, be protected from wetting and hydrostatic pressure buildup by an underdrain system. Job No. 105 299 M��i C%MOO \.r -3- The drains should consist of drainpipe placed in the bottom of the wall backfill surrounded above the invert level with free -draining granular material. The drain should be placed at each level of excavation and at least 1 foot below lowest adjacent finish grade and sloped at a minimum I% to a suitable gravity outlet. Free -draining granular material used in the underdrain system should contain less than 2% passing the No. 200 sieve, less than 50% passing the No. 4 sieve and have a maximum size of 2 inches. The drain gravel backfill should be at least 1'/z feet deep. Surface Drainage: The following drainage precautions should be observed during construction and maintained at all times after the residence.has been completed: 1) Inundation of the foundation excavations and underslab areas should be avoided during construction. 2) Exterior backfill should be adjusted to near optimum moisture and compacted to at least 95% of the maximum standard Proctor density in pavement and slab areas and to at least 90% of the maximum standard Proctor density in landscape areas. Free -draining wall backfill should be capped with about 2 feet of the on-site, finer graded soils to reduce surface water infiltration. 3) The ground surface surrounding the exterior of the building should be sloped to drain away from the foundation in all directions. We recommend a minimum slope of 12 inches in the first 10 feet in unpaved areas and a minimum slope of 3 inches in the first 10 feet in pavement and walkway areas. 4) Roof downspouts and drains should discharge well beyond the limits of all backfill. Percolation Testing: Percolation tests were not conducted due to Pitkin County's requirements for performing percolation tests after April 15 and the relatively shallow claystone bedrock encountered in the septic disposal area. The disposal system will likely need to be engineered. The septic disposal system should be designed by a civil engineer. We can assist the designer if percolation tests at shallow depth are needed. Limitations: This study has been conducted in accordance with generally accepted geotechnical engineering principles and practices in this area at this time. We make no warranty either express or implied. The conclusions and recommendations submitted in this report are based upon the data obtained from the exploratory pits excavated at the locations indicated on Figure 1 and to the depths shown on Figure 2, the proposed type of construction, and our experience in the area. Our services do not include determining the presence, prevention or possibility of mold or other biological contaminants (MOBC) developing in the future. If the client is concerned about MOBC, then a professional in this special field of practice should be consulted. Our findings include interpolation and extrapolation of the subsurface conditions identified at the exploratory pits and variations in the subsurface conditions may not become evident until excavation is performed. If conditions encountered during construction appear different from those described in this Job No. 105 299 G4 c'&ech C 0 •• report, we should be notified at once so re-evaluation of the recommendations may be made. This report has been prepared for the exclusive use by our client for design purposes. We are not responsible for technical interpretations by others of our information. As the project evolves, we should provide continued consultation and field services during construction to review and monitor the implementation of our recommendations, and to verify that the recommendations have been appropriately interpreted. Significant design changes may require additional analysis or modifications to the recommendations presented herein. We recommend on-site observation of excavations and foundation bearing strata and testing of structural fill by a representative of the geotechnical engineer. If you have any questions or if we may be of further assistance, please let us know. Respectfully Submitted, HEPWORTH - PAWLAK 2P A,�j°•., � X37'07` s� Jordy Z. Adamson, Jr., P. Reviewed by: v Steven L. Pawlak, P.E. JZA/ksw attachments Figure 1 — Location of Exploratory Pits Figure 2 — Logs of Exploratory Pits Figure 3 — Gradation Test Results cc: Sopris Engineering — Attn: Paul Rutledge Job No. 105 299 G, Hgtech 150 _ ff PIT 3 150 120 140 — DRIVEWAY I l � I I 1 � I 130 I 1 1 120 \ � PIT APPROXIMATE SCALE 1"=50' 110 I I I l l I PROPOSED RESIDENCE / 100 0 � � t LDING - JELOPE PIT 1 PROFILE r PIT ISDS EASEMENT HEPWORTH—PAWLAK LOCATION OF EXPLORATORY PITS Figure 1 105 299 GEOTECHNICAL, INC. PIT 1 IT 2 PIT 3 PROFILE PIT ELEV.= 109' ELEV.= 115' ELEV.= 147' ELEV.= 104' 0 0 Qo °o (0 o , +4=82 a� J -200=11 5 I I 5 L.=37 PI=14 t � «' n m 0 101 10 LEGEND: TOPSOIL; sandy clay with gravel, organics, roots, soft, moist, grayish brown. :p- = GRAVEL AND COBBLES (GC); shale fragments in a sandy clay matrix, medium dense, slightly moist, gray. CLAYSTONE SHALE BEDROCK; hard, slightly moist, dark gray. Mancos Shale. Disturbed bulk sample. _ J Practical digging refusal in bedrock with mini—trackhoe. NOTES: 1, Exploratory pits were excavated on April 8, 2005 with a Vermeer mini—trackhoe. 2. Locations of exploratory pits were measured approximately by pacing from features shown on the site plan provided. 3. Elevations of exploratory pits were obtained by "interpolation between contours shown on the s6te plan provided. Logs are drawn to depth. 4 The exploratory pit locations and elevations should be considered accurate only to the degree implied by the method used. 5. The lines between materials shown on the exploratory pit logs represent the approximate boundaries between material types and transitions may be gradual. g No free water was encountered in the pits at the time of excavating. Fluctuation in water level may occur with time. 7. Laboratory Testing Results: +4 = Percent retained on the No. 4 sieve —200 = Percent passing No. 200 sieve LL = Liquid Limit ( 7. ) PI = Plasticity Index ( % ) 105 299 HEPWORTH—PAWLAK LOGS OF EXPLORATORY PITS Figure 2 GEOTECHNICAL, INC. _Z WRJ-25-75 TYPE OR PRINT IN BLACK INK, COPY OF ACCEPTED STATEMENT MAILED ON REQUEST. COLORADO DIVISION OF WATER RESOURCES V RENEWED 818 Centennial Bldg., 1313 Sherman St.6197E Denver, Colorado 80203 I�t 1 STATE OF COLORADO SS. AFFIDAVIT�� COUNTY OF �.1'�'K1N — _ _ — STATEMENT OF BENEF)CIAL USE OF GROUND WATER g AMENDMENT OF EXISTING RECORD LATE REGISTRATION PERMIT NU ER R 65829 LOCATION OF WELL #1 #2 j oAi�tlAIdater Martin Fiala Tom Gilbert�D Pitkin _ whl-220il�aet Pl Dr 927 N Compo Rd7v*" address is Nps Yor NY of t DSW __ _ '/., Sect ar. -15-- Hollywood, Hollywood, CA 90069 e 10021 0680 Q ��ry R n . _Bpi _ �, b P M City.. _. 90 T-P---9-�.? 9 If oe wl (s..rrt i�tPr being duly sworn upon oath, deposes and says that he (they) is (are) the owner(s) of the well described hereon, the well is located as described above, at distances of--�.}Q0_— feet from the rxnnth section line and i,2or. feet From the IHOrrrr� OA snri•r.l West section line; water from this well was first applied to o beneficial use for the purpose(s) described herein on the 2-5- teat o« — !II day of dhr+..e 19_ ; the maximum sustained pumping rate of the well is 2Q_gallons per minute, the pumping do rate claimed hereby is < gallons per minute; the total depth of the well is ;>()n Meet, the overage annual amount of- water to be diverted s .___t*j0_._ acre-feet; for which claim is hereby made for purpose(s); the legal description of the land on which the water from this well is used is 110 acres —of which _ Q __acres are irrigated and which is illustrated on the map on the reverse side of this form; that this well was completed in compliance with t ermit approved therefor; this statement of beneficial use of ground water is filed in compliance with low- he (they) has (have) re the statements made hereof; k'}�ws the content thereof; and that the same ore true of his (their) knowledge. .t&M1�ICE]fE REVERSE�E OF THIS FORM) ,.i , Signature( s) Subscribed and sworn V nn a to before me on this -- l L 'day of f/ ��'� 19 My Commission expires: -h —� ✓rD l.wv vUD 41G ACCEPTED FOR FILING BY THE STATE ENGINEER OF COLORADO PURSUANT TO THE FOLLOWING CONDITIONS: THE PUMPING RATE CLAIMED SHALL NOT EXCEED FIFTEEN (15) GALLONS PER MINUTE. R FOR OFFICE USE ONLY Court Cose No. Jr 3 C `~ / J ._.__-- Prior r. Mo. ___ DoyYr. Di Cry. �- Sec. -------- i. --- --- --- 14 well use. -3___ --.- Dlsr, 3I Bos- Man. Drs M )EC 291 7 ------- - - r DAIF +ray Vyy STATE ENGINEER n Wel I drilled by Col I i n,a 'Dri I ling(. RodJ_A Cal t ins) Lic. No. 634 Permanent Pump installed by Glenwood Damp—(Merrill T?i shhjjrnLic. No. T 954 Meter Serial No. _� ❑ Flow Meter Date Installed jime P5, 197,J Owner of land on which water is being used .oiC}luxtter' Fiala. Gilbert 8Be DR 1 THE LOCATION OF THE WELL MUST BE SHOWN AND FOR LARGE CAPACITY IRRIGATION WELLS THE AREA ON WHICH THE WATER IS USED MUST BE SHADED OR CROSS -HATCHED ON THE DIAGRAM BELOW. NORTH This diagram represents nine (9) sections. Use the CENTER SQUARE (one section) to indicate the location of the well, if possible. WATER EQUIVALENTS TABLE (Rounded Figures) An acre-foot covers 1 acre of land 1 foot deep. 1 cubic foot per second (cfs) ... 449 gallons per minute (gpm). 1 acre-foot ... 43,560 cubic feet ... 325,900 gallons. 1,000 qpm pumped continuously for one day produces 4.42 acre-feet. 100 gpm pumped continuously for one year produces 160 ocre-feet. (WHITE AND PINK COPY TO BE FILED WITH THE STATE ENGINEER PINK COPY WILL BE RETURNED TO OWNER) i I + + 4 + + + NORTH SECTION LI E + + rn N us + J T 4 Z_ w + I Q + W SM'H SECI ION LI E THE SCALE OFT 1E DIAGRAM IS TWO INCHES E UALS ONE -MI E ---1 M i lel— 0 WATER EQUIVALENTS TABLE (Rounded Figures) An acre-foot covers 1 acre of land 1 foot deep. 1 cubic foot per second (cfs) ... 449 gallons per minute (gpm). 1 acre-foot ... 43,560 cubic feet ... 325,900 gallons. 1,000 qpm pumped continuously for one day produces 4.42 acre-feet. 100 gpm pumped continuously for one year produces 160 ocre-feet. (WHITE AND PINK COPY TO BE FILED WITH THE STATE ENGINEER PINK COPY WILL BE RETURNED TO OWNER) i I 1 WRIT -5_71 COLORADO DIVISION OF NATER RESOURCES 101 Columbine Bldg., 1845 Sherman Street, Denver, Colorado 80203 X � ,._J TYPE: OR PRINT IN BLACK INK. APPLICATION MUST BE COMPLETE,:) BEFORE; ACCEPTANCE. APPLICATION FOR: r A PERMIT TO USE GROM WATER A PERMIT TO CONSTRUCT A WELL REPLACEMENT FOR NO. A PERMIT TO INSTALL A PUMP OTHER APPLICANT 13alDh 0. -j uhh1t?y Box 3932 Street Address c Lcia P T4=a-n St Cit;; & State AS-ne Co10 91 L 1 Telephone No. �qp5 717 NAME OF AQUIFER GROUND WATER IS TO BE OBTAINED FROM: PROPOSED TOTAL DEPTH OF WELL 190 Ft. ESTIMATED MAXIMUM PUMPING RATE 15 GPM AVERAGE ANNUAL AMOUNT OF GROUND WATER TO BE APPROPRIATED 111-0 Acre-feet ANTICIPATED GROUT 'PROGRAM Material Ce I n Intervals 10 _ ?0 Placement Method Sp nk PROPOSED CASING: MUNICIPAL Plain �T in. from �_ ft. to ft. in. from ft. to ft. Perf.'_ in. from i n ft. to I 5n ft. in. from ft. to ft. Driller Cnl I i ns Tlri I J J rim No. -644 RECEIVED - `- �Mf� WELL LOCATION COUNTY 121 -skin 0 SW 4 of the ST{� 4 of Section 15 T • g.__ S R • P, f; W � 6 — P.M. IN ADDITION TO THE ABOVE, THE WELL MUST BE LOCATED WITH REFERENCE TO GOVERNMENT SURVEY CORNERS, MONUMENTS OR SECTION LINES BY DISTANCE AND BEARING (DOMESTIC WELLS MAY BE LOCATED BY LOT, BLOCK, & SUBDIVISION.) —12 -Da— ft. from S n I i tb section line North or South 2200 ft, from section line East or West LOT BLOCK FILING # SUBDIVISION Ground Water Basin (+nl nra o Ri yer Water Mgmnt. Dist. 38 Anticipated drilling date Owner of land on which well is located: Same 19 72 Other water rights on this land _ T?nn e_ gnature of Applicant Address Carnnnr3 i e r n n Ri ti9x IF WELL IS USED FOR IRRIGATION, BACK SIDE OF TI -IIS APPLICATION MUST BE COMPLETED FOR OFFICE USE ONLY CONDITIONS OF APPROVAL APPLICATION APPROVED: VALID FOR YEARS This well shall be used In such a way as to not cause AFTER DATE ISSUED UNLESS EXTENDED FOR GOOD The material injury to existing water rights.,icant that noe CAUSE SHOWN TO THE ISSUING AGENCY. of this permit goes not assure the app injury will ccc�r co another vested water tight or PERMIT NO. 65829 preculde another owner of a vestod water right frtue OCT 2 5 1972 seeking relief in a civil court action. DATE ISSUED THE RETURN FLOW FROM THE USE OF 'MS . WELL MUST BE RETURNED TO pT,HE SANESTREAMSBTREATMM SYYSTTEIM IN WHIICII zr�" 40AG�LTRACTEtw, BEDOASESW� OFNTHE� 8F A STAT E IAEER Nip SECTION l5, T9S, 6th BY PERMIT EXPIRATION EXTENDED NINE (9) MONTHS TO AUGUST 25— 1.97.5___. 1:'AIER RCWUR4-E3 GROUND WATER TO BE USED FOR: SI"i= nc�acE�c v DOMESTIC 1 CAERCIAL (4) LIVESTOCK (2) INDUSTRIAL (5) MUNICIPAL (8) IRRIGATION (6) OTHER Hniinr?hnld &Stocj{_ WELL LOCATION COUNTY 121 -skin 0 SW 4 of the ST{� 4 of Section 15 T • g.__ S R • P, f; W � 6 — P.M. IN ADDITION TO THE ABOVE, THE WELL MUST BE LOCATED WITH REFERENCE TO GOVERNMENT SURVEY CORNERS, MONUMENTS OR SECTION LINES BY DISTANCE AND BEARING (DOMESTIC WELLS MAY BE LOCATED BY LOT, BLOCK, & SUBDIVISION.) —12 -Da— ft. from S n I i tb section line North or South 2200 ft, from section line East or West LOT BLOCK FILING # SUBDIVISION Ground Water Basin (+nl nra o Ri yer Water Mgmnt. Dist. 38 Anticipated drilling date Owner of land on which well is located: Same 19 72 Other water rights on this land _ T?nn e_ gnature of Applicant Address Carnnnr3 i e r n n Ri ti9x IF WELL IS USED FOR IRRIGATION, BACK SIDE OF TI -IIS APPLICATION MUST BE COMPLETED FOR OFFICE USE ONLY CONDITIONS OF APPROVAL APPLICATION APPROVED: VALID FOR YEARS This well shall be used In such a way as to not cause AFTER DATE ISSUED UNLESS EXTENDED FOR GOOD The material injury to existing water rights.,icant that noe CAUSE SHOWN TO THE ISSUING AGENCY. of this permit goes not assure the app injury will ccc�r co another vested water tight or PERMIT NO. 65829 preculde another owner of a vestod water right frtue OCT 2 5 1972 seeking relief in a civil court action. DATE ISSUED THE RETURN FLOW FROM THE USE OF 'MS . WELL MUST BE RETURNED TO pT,HE SANESTREAMSBTREATMM SYYSTTEIM IN WHIICII zr�" 40AG�LTRACTEtw, BEDOASESW� OFNTHE� 8F A STAT E IAEER Nip SECTION l5, T9S, 6th BY PERMIT EXPIRATION EXTENDED NINE (9) MONTHS TO AUGUST 25— 1.97.5___. REPORT DATE COLORADO WELL APPLICATION'-' AND PERMITS Fri Apr 29 13:12:04 MDT 2005 i.OLORADO DIVISION OF WATE. RESOURCES Receipt 9117276 Permit 65829 Div 5 Wd 38 Basin Md Engineer User AOT Full Name Uses SCHUSTER ROBT & FIALA, MARTIN & GI DOMESTIC Address 404 E 66TH STOCK City State Zip NEW YORK NY 10021 Pump Rate Ann Amt Depth Telephone Proposed 0.00 0.00 0 ( ) Actual 15.00 0.00 200 Case Irrigated Area 0.00 acres Permit XRef Elevation 0 Well Name Perf Casing Top 148 County PITKIN Perf Casing Bottom 200 Q10 Water Level 105 Q40 NE Aquifer1 ALL UNNAMED AQUIFERS Q160 SW Aquifer2 Sec 15 Driller 634 Ts 9 South Pump Installer 954 Rng 86 West Statute Meter Log Qual AbReq Pm Sixth 6023 No No No No 1500 feet from South Section line Comment 1700 feet from West Section line Subdivision Filing Block Lot Parcel Size PIN 0.00 Main Activity 09-14-1972 Interim Status Last Action 11-17-2004 Record change. A portion of the file was modified/corrected. Permit Issued 10-25-1972 Permit Expires Expire Notice Sent Well Const Report 01-02-1976 Well Const Complete 08-10-1975 Well Report (Non-trib) Pump Install Report 08-04-1978 Pump Install Complete 06-28-1978 1st Beneficial Use 06-25-1978 Statement Benef. Use Benef Use (Non-trib) Abandonment Report Well Plugged W J R-26 -7 7 D COLORADO DIVISION OF WATER RESOURCES RECLINED THIS FORM MUST BE SUBMITTED 1313 Sherman Street - Room 818 WITHIN 60 DAYS OF COMPLETION Denver, Colorado 80203 �'► OF THE WORK DESCRIBED HERE- ON. TYPE OR PR1NT IN BLACK WELL COMPLETION AND PUMP/ INSTALLATION REPORT r INK. PERMIT NUMBER' l�s � ( MR ENMMBP � r COWS WELL OWNER DY4 of the Y. of Sec. ADDRESS�))x 141 '19.9 9g'2 E'_,rL T. R. P.M. DATE COMPLETED.srto n g S 19 IQ� HOLE DIAMETER WELL LOG in. from to ft. Water From To Type and Color of Material Loc. TOTAL DEPTH Use additional pages necessary to complete log. in. from to ft. in. from to ft. DRILLING METHOD CASING RECORD: Plain Casing Size & kind from to ft. Size & kind from to ft. Size & kind from to ft. Perforated Casing Size & kind from to ft. Size & kind from to ft. Size _ _ & kind from to ft. GROUTING RECORD Material Intervals Placement Method . GRAVEL PACK: Size Interval TEST DATA Date Tested Static Water Level Prior to Test Type of Test Pump Length of Test Sustained Yie)d (Metered) Final Pumping Water Level ,19 ft. a v 1 W RJ -26-72 COLORADO DIVISION OF WATER RESOUR RECEIVED TF!fS rORM MUST BE SUBMITTED 101 Columbine Bldg., 1845 Sherman St. WITHIN 60 DAYS OF COMPLETION Denver, Colorado 80203 OF THE WORK DESCRIBED HERE- U ON. TYPE OR PRINT IN BLACK WELL COMPLETION AND PUMP INSTAL LLATION REPORT INK. PERMIT NUMBER l 486 /_ - WATER ENGM -11 STATE �giNEER COLO. WELL OWN�&4 = �_'/4 of the __$.%_�'/4 of Sec. � , ADDRESS O T. — — R. --z""_ — -, P.M. DATE COMPLETED HOLE DIAMETER w�I I Ina in. from From To Type and Color of Material Water Loc. �/"- Ire ° v Use i TOTAL DEPTH additional pages necessary to complete log. in, from to ft. in. from to ft. CASING RECORD. �i�aiPlain Casing Size � & kind _�—.from to ft. Size 4__& kind _12 .-_- from x=TOA% Size —& kind from to ft. //P+�e�rfoorated Casing Size _�_ & kind oe nc _— from _'4o _'Z'na ft. Size --& kind from to ft. Size & kind from to _ ft. GROUTING RECORD Material Intervals I Placement Method /w, OX GRAVEL PACK: Size Interval — — — TEST DATA Date Tested -J10 — 19 a Static Water Level Prior to TTJeest � ___.-_- — ft. Type of Test Pump __e 7_�.�. Length of Test 2xe_S_1__ Sustained Yield (Metered) Final Pumping Water Level PUMP INSTALLATION REPORT lump Make rype --- lowered, by _ lump Serial No: Viotor Serial No. )ate Installed -lump Intake Depth 3emarkselea, a) YELL TEST4 DATA WITH PERMANENT PUMP )ate Tested static. Water Level Prior to Test _ength of Test Hours Sustained yield (Metered) GPM -lumping Water ,Let(vel (t 1 Remarks ui hojoulN CONTRACTORS STATEMENT The undersigned, being duly sworn upon oath, deposes and says that he is the contractor of the well or pump installation described hereon; that he has read the statement made hereon; knows the content thereof, and that t same is true of his ow nowledge. h r Signature License No. State of Colorado, County of GoxfisId SS Subscribed and sworn'to before me this _ZJ& day of Deceaber , 19--75. My Commission expir October �__ , 19 Notary Public FORM TO BE MADE OUT IN QUADRUPLICATE: WHITE FORM must be an original copy on nota sloes ano signea. WHITE AND GREEN copies must be filed with the State Engineer. PINK COPY is for the Owner and YELLOW COPY is for the Driller. PUMP INSTALLATION REPORT Pump Make In —Rt lC511 It P Type -> 11 b ate, +p_ Powered by A �41 fc HP Pump Serial No. Motor Serial No. j(,L,h r 7d Date Instal leo ��J• Pump intake Depth Remarks WELL TEST DATA WITH PERMANENT PUMP Date Tested J 11 hStaticStatic Water Level Prior to Test Length of Test I—V Hours Sustained yield (Metered) Q_ GPM Pumping Water Level _ Remarks WATER TABLE i cON E OF DEPRESSION CONTRACTORSSTATEMENT The undersigned, being duly sworn upon oath, deposes and says that he is the contractor of the well or pump installation described hereon; that he has read the statement made hereon; knows the content thereof, and that the ffsame is true of*4'-�s, his own knowledge. Signature _f�`7-" � � /1. ��lt ����_� License No. gcsy State of Colorado, County of COA." Akq Afl __�_ r SS Subscribed and sworn to betore me this ?---I day of , 19 My Commissio expires: MYCOMInEWORExplrasfte,1982 , 19 Notary Pub FORM TO aE MADOl IN QUADRUPLICATE: WHITE FORM must be an original copy on notn sues ana svw— WHITE AND GREEN copies must be filed with the State Engineer. PINK COPY is for the Owner and YELLOW COPY is for the Driller. �w :t W - — — — ,a— t� ;s r � � a i WATER TABLE i cON E OF DEPRESSION CONTRACTORSSTATEMENT The undersigned, being duly sworn upon oath, deposes and says that he is the contractor of the well or pump installation described hereon; that he has read the statement made hereon; knows the content thereof, and that the ffsame is true of*4'-�s, his own knowledge. Signature _f�`7-" � � /1. ��lt ����_� License No. gcsy State of Colorado, County of COA." Akq Afl __�_ r SS Subscribed and sworn to betore me this ?---I day of , 19 My Commissio expires: MYCOMInEWORExplrasfte,1982 , 19 Notary Pub FORM TO aE MADOl IN QUADRUPLICATE: WHITE FORM must be an original copy on notn sues ana svw— WHITE AND GREEN copies must be filed with the State Engineer. PINK COPY is for the Owner and YELLOW COPY is for the Driller. �4 1 %J THE LOCATION OF THE PROPOSED WELL MUST BE SHOWN AND THE AREA TO BE IRRIGATED MUST BE SHADED OR CROSS -HATCHED ON THE DIAGRAM BELOW This diagram represents nine (9) sections. Use the CENTER SQUARE (cne section) to indicate the location of the well., if possible. I+_,'Mile-.� Owner of irrigated land THE SCALE OF THE DIAGRAM IS TWO INCHES EQUALS ONE -MILE 1 Number of acres to be Legal description of )) � c irrigated land W ({ C) f-cJ E '' [)`j E WATER EQUIVALENTS TABLE (Rounded Figures) '-7— 7 S (2 �_6 CJ (9 An acre-foot covers 1 acre of land I foot deep. 1 cubic foot per second (cfs) ... 449 gallons per minute 1 acre-foot .... 43,560 cubic feet .... 325,900 gallons. 11000 gpm pumped continuously for one day produces 4.42 acre-feet. 100 gpm pumped continuously for one year produces 160 acre-feet. NORTH SECTION LINE w w 0 H 0 U + X U SOUTH SECTION L + + + + + I Owner of irrigated land THE SCALE OF THE DIAGRAM IS TWO INCHES EQUALS ONE -MILE 1 Number of acres to be Legal description of )) � c irrigated land W ({ C) f-cJ E '' [)`j E WATER EQUIVALENTS TABLE (Rounded Figures) '-7— 7 S (2 �_6 CJ (9 An acre-foot covers 1 acre of land I foot deep. 1 cubic foot per second (cfs) ... 449 gallons per minute 1 acre-foot .... 43,560 cubic feet .... 325,900 gallons. 11000 gpm pumped continuously for one day produces 4.42 acre-feet. 100 gpm pumped continuously for one year produces 160 acre-feet. f r .o 9C ;t 3' 0 �r rh Recorded PM March 24, 1978 Reception t$60(�,.if; Julie Hane Recorder BOOK345 rt,..20:' WATER WELT, AND UTILITIE'S AGREEMENT THIS AGREEMENT entered into this � day of March, 1978 between Martin J. Fiala, Robert — berrttJ. Schuster, R. C. Ashley and R. Elghammer and Thomas S. Gilbert, WITNESSET Ii : WHEREAS, Ralph C. Ashley, Richard Elghammer and martin Fiala and Robert T. Schuster have drilled a water well on the real property described on Exhibit "A" attached hereto and incorporated herein; and WHEREAS, Ralph C. Ashley and Richard Elghammer have sold, conveyed and assigned all of their rights to said real property to Thomas S. Gilbert, and, WHEREAS Ailbert, Fiala and Schuster are desirous of further defining the rights, obligations and duties regarding the completion operation and maintenance of said well and domestic water system pursuant to the previous agreements made between the parties; NOW, THEREFORE, in consideration of the mutual promises made herein and other good and valuable consideration the parties hereto agree as follows: I. GRANT OF EASEMENT Gilbert hereby quit claims and convey= to Fiala and Schuster a perpetual non-exclusive easement and right of way over and across the following described real property: See Exhibit "A" attached hereto and incorporated herein. The purposes of said easement shall be limited to the right to excavate for, install, replace and maintain and use all necessary equi.pmcnt and appurtenances for the operation of the existing well and of a mutual domestic water system for residential use. Gilbert further grants Fiala and 345 :!,; 20 Schuster the i icjhL to bring electrical phone services across the 57 acre tract owned by Gilbert and terminating in the one acre easement described on Exhibit "A" attached hereto and incorporated herein. II. MAINTENANCE AND EXPENSE SHARING The parties agree to share equally the water from said well for their respective single family residences. It is agreed that Fiala, Schuster, Ashley and Elghammer shall install, at their expense, a pump adequate to handle the domestic needs of the parties no later than July 1, 1978. Subsequent to the installation of the well pump the costs of maintenance, construction of necessary holding tank facilities and other necessary improvements tur the water system and repair of the well and power and phone line installations shall be shared equally between Fiala, Schuster and Gilbert PROVIDED, HOWEVER, that each of the foregoing parties shall be responsible for the extension of all water lines, phone and power lines from the well site and easement area to their respective residences. With regard to actual power necessary to operate the well pump, this cost shall be shared equally by those parties who have extended water lines from the well to their residences. At such gime as each party extends his water line from the well to his residence he shall assume his pro -rata share of electrical expense necessary to operate said well. Any charge or assessment shall be due and payable within thirty (30) days from the receipt of statement from any party to this agreement, his heirs, executors and assigns. 04 .— ADJUDICATION OF WELI, Ashley and Elghammer agree that as soon as is practically possible they shall file Z statement of beneficial use regarding said well and take all necessary steps, pursuant to the applicable statutes and regulations of the State of Colorado, to have said well adjudicated in the names of Fiala, Schuster and Gilbert, each having a one-third (1/3) interest in said well. The legal costs and other expenses of said adjudication shall be borne equally by Fiala, Schuster and Gilbert. IV. MISCFT,T,ANEOUS Fiala and Schuster acknowledge that Gilbert intends to construct a 1,600 square foot single family dwelling plus a garage on the one acre easement tract attached hereto as y Exhibit "A" and incorporated herein, and agree that the ease- ment rights granted herein shall be exercised only i„ such a manner as to not interfere with the construction of said house P. -r-4.-.1 ti-._ Vic, ;�. 4.5 n(+ 6.,,13" i» z_. k .� tw%mui;ef �?lat.t by Gilbert'A In addition, .Fiala and Schustcr's easer.+ent rights herein, including the right of ingress and egress for extension _ � Y of water lines, repair of the water system and power and phone s- line extensions shall at all times be exercised in such a manner as to cause the least damage and inconvenience to Gilbert and to the land owned by Gilbert burdened by this easement. It shall% v F• � be! the responsibility of each party extending water, phone or power lines to his respective residences to restore the land to its original condition after excavation. H It is understood that this agreement shall be binding upon the parties hereto *and upon any and all of their heirs, executors, personal representatives and assigns, who shall - , hereafter acquire title to the within granted easement. - 3 L Qa 1.45 z ,:209 This Agreement may be executed simultaneously on or in counterparts by the parties. Each such counterpart shall be deemed an original but when taken together shall constitute one and the same document. IN WITNESS WHEREOF, the parties hereto have set their "1,�lrai�ds aLs�ea$ELQn the date and year first above written, �<"�'r TARY PUBLIC, State of Now Yolk No. 491141/ STATE OF NEW YORK (1n^n ie i Pil-.,rork Count), COUNTY OF NEW YORK e.+ ' • tir t. ri1eJ In Now York L'oant) (} ; Mainmttaion uplrya Mach 3o, s 4ub'scribed and sworn to before me ,*,his 1 S� day of March, 1978. 5i1 Martin J. F a lV Notidry Public Subscribed and sworn to before me this day of March, 1978. Notary PuSlic Subscribed and sworn to before me this day of March, 1978. Notary Pu lic Subscribed and sworn to before me this day of March, 1978. ) Notary Public VIP ....... �t3Ye�Q��.•• •Subscri�3ec� a d sworn to before me RT .•t'h ' % day of M c , 1978. u .n .Gtr t Not' > c ��t 1111111111111'1 •,, Lam' w 4 r RoSert J. Schuster Richard E g ammer Ralph C. Ashley T omas S. Gilbn Situate gtinrter describ of a 60 of said fectt t. South a West 20 easemen, said roi feet al( consist: lwl EXHIBIT "A" Situated in the Northeast quarter of the Southwest quarter of said Section 15 T9S R86W, said easement is described as follows: Beginning at a point in the center of a 60 foot road easement whence the Southwest corner of said Section 15 bears: South 47050131" West 2525.51 feet; thence South 43033'08" East 215.71 feet; thence South 44022103" West 208.08 feet; thence North 43033108" West 208.71 feet to point in the center of said road ease,ment; thence North 46126'52" East 70.00 feet along said road easement; thence North 40°25131" East 138.71 feet along said road easement, to the point of beginning, consisting of approximately 1 acre, more or less. 40 L*] EXHIBIT "A" 0. a�r.v3 5 ;.•.� .i VV. .. Situated in the Northeast quarter of the Southwest quarter of said Section 15 T9S R86W, said easement is described as follows: Beginning at a point in the center of a 60 foot road easement whence the Southwest corner of said Section 15 bears: South 47°50131" West 2525.51 feet; thence South 43°33108" East 215.71 feet; thence south 44022103" West 208.08 feet; thence North 43°33'08" West 208.71 feet to point in the center of said ruad easement; thence North 46026152" East 70.00 feet along said road easement; thence North 40025131" East 138.71 feet along said road easement, to the point of beginning, consisting of approximately 1 acre, more or less. CIN I 4 4:28 PM March 24, 1978 R, WATEK ' THIS AGREEM March, 1978 betty R. C. Ashley and WITNESSETH: WIIEREA 6, R" Martin riala and well on the real attached hereto WHEREAS, R, sold, conveyed i real property tc WHEREAS Gi: fnrther definint the Completion domestic water made between th NOW, TIIERE made herein and parties hereto Gilbert hE Schuster a perl way over and a, See Inco The purposes o to excavate fo necessary eyul the existing H for residentic Form STATE OF COLORADO For Office Use Only No. OFFICE OF THE STATE ENGINEER GWS -11 6/2003 818 Centennial Bldg., 1313 Sherman St., Denver, CO 80203 (303) 866-3581 Fax (303) 866-3589 CHANGE IN OWNERSHIP/ADDRESS CORRECTION OF THE WELL LOCATION Insert the Well Permit Number Name, address and phone of the person claiming ownership of the well: NAME(S) Mailing Address City, St. Zip Phone ( 1 This form is filed by the named individual/entity claiming that they are the owner of the well permitted as referenced above. This filinq is made pursuant to C.R.S. 37-90-143. WELL LOCATION: County _ _ Owner's Well Designation (Address) (City) (State) (Zip) 1/4 of the 1/4, Sec. , Twp. ❑ N. or ❑ S., Range ❑ E. or ❑ W., P.M. Distance from Section Lines Ft. From ❑ N. or ❑ S., Ft. From ❑ E. or ❑ W. Line. Subdivision Name Lot , Block , Filing/Unit The above listed owner(s) say(s) that he, she (they) own the well described herein. The existing record is being amended for the following reasons: ❑ Change in name of owner ❑ Change in mailing address ❑ Correction of location for exempt wells permitted prior to May 8, 1972 and non-exempt wells permitted before May 17, 1965. Please see the reverse side for further information regarding correction of the well location. I (we) claim and say that I (we) (are) the owner(s) of the well described above, know the contents of the statements made herein, and state that they are true to my (our) knowledge. Please print the Signer's Name & Title Signature(s) of the new owner. Date It is the responsibility of the new owner of this well to complete and sign the form. Signatures of agents are acceptable if an original letter of agency signed by the owner is attached to the form upon its receipt. For Office Use Only State Engineer By Date 6/2003 INSTRUCTIONS CHANGE OWNERSHIP -ADDRESS -LOCATION CORRECTION FORM NO FEE IS REQUIRED The form must be typewritten or printed in BLACK INK. Initial and date any changes you make on the form. THIS FORM MAY BE REPRODUCED BY PHOTOCOPYING OR WORD PROCESSING MEANS. INCOMPLETE FORMS WILL BE RETURNED. Be sure to include the well permit number in the space provided at the top of the form. The form is to be completed by the new owner (the individual, company or entity claiming ownership of the well). Print the new owner's name and include the mailing address and phone number. Complete the Well location information. If the address of the well location is different than the mailing address of the owner, include the address where the well is located. The actual well location must include %, %, Section, Township and Range. Check the appropriate boxes for North or South and East or West directions. Complete the Subdivision, Lot, Block and Filing information, if applicable. Indicate in the appropriate boxes if the form is submitted to change the ownership and/or address, or both. The individual, company or entity claiming ownership of the well must sign the form. If you are signing as a representative of a company who owns the well, then your title must also be included in the first block. Sign the second block and date the last block. USE 'THIS FORM TO CORRECT THE LOCATION OF YOUR WELL IF: A. Your well was permitted, registered, or first used prior to May 8, 1972 for ordinary household purposes in up to three single-family dwellings, fire protection, the watering of poultry, domestic animals, and livestock on farms and ranches and the irrigation of not over one acre of home gardens and lawns. B. Your well is not of the type described in A above, but was permitted or registered prior to May 17, 1965. Inside the Designated Ground Water Basins, other procedures and publication may be required. C. Your well was, decreed by the Water Court for the correct location. IN ALL OTHER CASES USE FORM GWS -42 (CORRECTION OF WELL LOCATION FORM). If you have questions, contact the Denver Office or the Division Office where your well is located. Division 1 Division 2 Division 3 Division 4 810 91' St. 2nd Floor 310 E. Abriendo Ave Ste B 301 Murphy Drive 1871 East Main St. Greeley, CO 80631 Pueblo, CO 81004 Alamosa, CO 81101 Montrose, CO 81402 (970) 352-8712 (719) 542-3368 (719) 589-6683 (970) 249-6622 Fax 970 391-1816 Fax 719 5440800 Fax 719 589-6685 Fax 970 249-8728 Division 5 Division 6 Division 7 Denver Office Direct mail to Box 396 Direct mail to Box 773450 701 Camino Del Rio Ste. 205 1313 Sherman St. Rm. 818 Glenwood Spgs CO 81602 505 Anglers Dr. Suite 101 Durango, CO 81301 Denver, CO 80203 50633 U.S. Hwy 6 & 24 Steamboat Spgs, CO 80477 (970) 247-1845 (303) 866-3581 Glenwood Spgs., CO 81601 (970) 879-0272 Fax (303) 866-5417 Fax (303) 866-3589 (970) 945-5665 Fax (970) 879-1070 Fax 970 945-8741 Call First BUILDER MUST CHECKAND VERIFY IN WHOLE OR IN PART, WITHOUT EXPRESS WRITTEN PERMISSION OF JAMISON DESIGN LLC. COPY CENTERS PLEASE ASK FOR PROOF OF PERMISSION TO COPY THIS DRAWING ALL DIMENSIONS, LOADS, AND CONDITIONS 5117WALL INSULATION VAPOR BARRIER 112" DRYWALL 7' X B" BOTTOM PLATE S' LAP SIDING HOUSE WRAP (BUILDING PAPER) 117' EXTERIOR SHEATHING WOOD WALL SYSTEM - 2"X 6" X 8' STUDS W/ 6" LAP SIDING Simpson Strong -Tie LTB40 FLOOR BRIDGNG Simpson Strong -Tie LSSU210 RIDGE BEAM ! "I" JOIST HANGERS BUILDER MUST CHECKAND VERIFY ALL DIMENSIONS, LOADS, AND CONDITIONS U .J ..1 J d ,Z,n V =_L r W L U 010 ti L � \ 0p N V o .Q 'T J F, N m v �°cM d m o -1 0 p O E UJ L U- o -1 C a W U LL O W In E � f N .i. LD U d Drawn By: S.Jamison Date: 7/20/04 Design By: S.Jamison Checked By: W.Jamison Scale: SEE DRAWING REVISIONS LUQ O F- H Z U-1 2 O U Z O U-1 x Sheet No. A�2 JOB NO. 04126 0 0 Q «¢YO Q z J � W O O } � O� O Drawn By: S.Jamison Date: 7/20/04 Design By: S.Jamison Checked By: W.Jamison Scale: SEE DRAWING REVISIONS LUQ O F- H Z U-1 2 O U Z O U-1 x Sheet No. A�2 JOB NO. 04126 \ \ \ \ GENERAL NOTES: \ \ \ \ \ \ \ \ \ \ \ \ PRESSURE DOSED SAND FILTER BED NOTES 1. THE EXISTING CONTOUR INTERVAL IS ONE (2) FOOT (DASHED). \ \ APPROXIMATE LbCAPON\OF DRIVEWAY SURFACE \ \ \ \ 1 DIMENSIONS MINIMUM 2. EXISTING CONDITIONS ARE FROM HIGH COUNTRY ENGINEERS INC. PROPOSED OWS DESIGN BY SOPRIS ENGINEERING, LLC. BUILDING ENVELOPE LENGTH,AN WIDTHS AND SEPARATION DISTANCES S FOR THE TRENCHES, ED OR \ \ \ \ \ \ MOUNDED ABSORTION FIELD. 3. THE PROPOSED RESIDENTIAL BUILDING LAYOUT, AND OTHER SITE \ \ \ \ \ \ \ IMPROVEMENTS BY JAMISON DESIGN LLC. \ \ \ \ \ 2, THE ABSORPTION BED SHALL BE EXCAVATED AND FILLED 70 LEVEL GRADE. \ \\ \ \ \ LEACHING CHAMBERS WILL BE PLACED IN THE BED OVER 24" OF SELECT \ \ \ \ \ \ \ \ \ \ FILTER SAND OVERLYING THE NATIVE SOIL OR SPECIFIED IMPORT MATERIAL. THE BED BOTTOM AND SIDEWALLS SHALL BE SCARIFIED. OWS SYSTEM NOTES \ \ \ \ \ \ \ \ \ \ \ \ \ 3. \ \ \ \ \ \ \ \ THE LEACHING CHAMBERS SHALL BE INSTALLED LEVEL WITH A MINIMUM COVER 1. ALL MATERIALS AND INSTALLATION SHALL CONFORM TOSS. AND COUNTY \ \ \ \\ \ \ \ OF 10 INCHES NOT 70 EXCEED 24 INCHES AND INSTALLED WITH 1.25' PERFORATED PRESSURE DISTRIBUTION ON TI INDIVIDUAL SEWAGE DISPOSAL SYSTEM (ISOs) REGULATIONS. \ \ \ \ PIPES INSTALLED THE TOP SURFACE \ \ \\ \ \ \ \ \ \ \ OF THE SAND LAYER BELOW THE CHAMBERS. EQUAL PRESSURE DISTRIBUTION OVER THE LENGTH OF EACH TRENCH WILL BE MAINTAINED BY 3/16" 2. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO CONTACT UTILITY LOCATORS \ \ \ \ \ \ \ \ QUICK -4 END CAP (TYP. \ \ 7 ORIFFICES DRILLED ON 2.5' CENTERS ALONG THE PIPE. THE ORIFICES SHALL AND UTILITY COMPANIES AS NEEDED FOR FIELD LOCATIONS OF UTILITIES PRIOR TO CONSTRUCTION AND EXCAVATION. \ \ � J \ BE ORIENTED AT 72 O'CLOCK. 3GRAVITY SEWER TTHERWISE. ASCHEDULESDR-35, OR I PE \ \ \ 4. THE DUAL 1.5" TRANSPORT LINES FROM THE PUMP BASIN SHALL BE UNLESSNOTED ALL GRAVITY SEWER LINES TO BE INSTALLED ON A \ \ INSPECTION PORT (TYP.1 \ INSTALLED 7O DISCHARGE EFFLUENT TO THE ABSORPTION FIELD THROUGH THE 2% GRADE. LINES MAY BE STEPPED DOWN BETWEEN 2% RUNS. \ \ \ \ \ \ \ 1.5" SOLID HEADER PIPE AND EXTENSIONS THAT CONNECT 70 EACH 1 1/4" \.75 PERFORATED PRESSURE DISTRIBUTION PIPES IN EACH BED. MAINTAIN A 4. ALL PRESSURE LINES TO BE SCHEDULE 40 P.V.C. OR HDPE SDR -9 PIPE UNLESS \ \ MINIMUM DEPTH OF COVER OF 2 FEET OVER TRANSPORT LINE WITH A MINIMUM NOTED OTHERWISE. PRESSURE LINES 70 BE INSTALLED WITH A MINIMUM 2% \ \ \ \ \ \ \\ 2% SLOPE GRADE TO ALLOW THE LINE TO DRAIN EFFLUENT THROUGH THE TRANSPORT HEADER PIPES. THE TRANSPORT LINE CONNECTION FIT71NG ON HEADER PIPE GRADE FOR DRAINAGE. NO LOW POINTS OR DIPS ARE ACCEPTABLE ALONG PRESSURE PIPE RUNS. \ \ \ 22$$•ERFORATED \ \ \ \ 1-61STRIB ON LATER\AL SHALL BE INSTALLED SLIGHTLY HIGHER THAN THE INDIVIDUAL DISTRIBUTION \ \ \ \ \ \ TEES. THE PRESSURIZED FLOW WILL SPLIT AT THE 1 5" HEADER PIPE LINE 5. ALL GRAVITY AND PRESSURE LINE 70 BE BEDDED IN ROAD BASE OR SUITABLE \ \ \ AND EQUALLY DISTRIBUTE THROUGH EACH DISTRIBUTION LINE EXTENSION TO ONSITE MATERIAL IN COMPACTED TRENCHES AND BACKFILLED WITH A MINIMUM THE PERFORATED DISTRIBUTION LATERALS. THE INVERT OF THE PRESSURIZED TRANSPORT LINE FITTING A7 THE HEADER PIPE SHALL BE A7 LEAST 2" OF 6" SUITABLE ON SITE MATERIAL OR ROADBASE. MINIMUM DEPTH OF BURY ABOVE THE INVERT OF THE PERFORATED DISTRIBUTION LINES OF ALL SEWER LINES SERVICE LINES IS 3'. r1�\ � \ 50.5' X 11' SAND FILTER BED WITFi1 ' S. 6. INSTALL ATWO-WAY CLEAN OUT ON THE SEWER LINE FROM THE BUILDING. \ \ \24. OF CDNCRET€ SAND (TYP.) END PLATES SHALL BE INSTALLED ON THE END CHAMBERS IN EACH TRENCH. ADDITIONAL CLEANOUT REQUIRE AT UPSTREAM GRADE BREAKS. \ TWO -WA \�\ \ \ CLEANOUT \ `O� V ` \ \ \ I TWO 3116 ORIFICES SHALL BE DRILLED ON EITHER END OF THE PRESSURE DISTRIBUTION PIPE AND ORIENTED AT 6 O'CLOCK 7O ALLOW FOR DRAINAGE. A 7. THE SEPTIC TANK SHALL BE WATERTIGHT AND INSTALLED LEVEL ON COMPACTED APPRGVf MATE LIMITS ICF FILL SPLASH PLATE OR ORIFICE SHEILD SHALL BE INSTALLED BELOW THE DRAIN EARTH. THE TANK SHALL BE CERTIFIED AS WATERTIGHT BY THE MANUFACTURE. DAYLGFIT SIDESLOPE AT 3:1 ORIFICES ON EITHER END OF THE PRESSURIZED DISTRIBUTION LATERALS ON THE TANK SHALL BE TESTED FOR WATERTIGHTNESS AFTER PLACEMENT AND THE TRENCH SURFACE. PRIOR TO BACKFILL INSTALL WATERTIGHT RISERS AS NECESSARY TO BRING ALL REQUIRED ACCESS POINTS TO THE FINISHED SURFACE GRADE. \J 1 II 6. \ \ I� INSTA`LL.ED ABSORPTION FIELD Wf PRESSURE DOSED 7RENPFi ES USED CUSTOM PER�FQATED 1.255• PVC PRESSURE VERTICAL INSPECTION PORTS SHALL BE INSTALLED FROM THE CENTER PRE MARKED HOLE ON THE TOP OF THE END CHAMBERS. (TYP. END OF EACH B. A SANITARY BAFFLE TEE IS REQUIRED ON THE SEPTIC TANK INLET. \ \ / 4• AGE LINE Ui I \ PIPEIINSTALLED THE TOP Of THE SAND FILTER BED ROW) THE PORTS MAY HAVE TREADED CAPS A7 GRADE. INSTALL THE INLET TEE PLUMB AND IN A POSITION 70 ALLOW EASY INSPECTION THE TANK RISERS. \ \ � FROM HOUSE SURFACE BELOW THE LEACHINq CHAMBERS INSTALLED 72 I 7• WITH EXCAVATED MATERIAL AND MAINTAINANCE OF TANK FROM O 2% SLOPE I QUICK -4 LEACHINGCHAMBERSIIN TWO BEDS WITH 3 ROWS O THE CHAMBERS WILL BE BACKFILLED VOID OF 11iE BACKFILL MATERIAL SHALL NOT EXCEED 2 1/2" DIAMETER AND 9. FOR PUMP SYSTEMS: WE RECOMMEND THE INSTALLATION AN ORENCOIN \ \ Z � � OF r2 CHAMBERS PER ROW. INSTALL OVER 24" OF FILTER SAND IN 50.5' X I1' BEDS FOR A TOTAL OF ROCKS, SHALL BE PLACED 70 AT LEAST 6 INCHES ABOVE THE TOP OF THE LI BIO -TUBE SCREEN VAULT FOR THE DUPLEX PUMP ASSEMBLIES 70 BE INSTALLED \ \ S I \ 6 I 110 SQ. FT. FILTER AREA{ LOCATION OF THE CHAMBERS. THE TOP OF THE PLACED BACKFILL SHALL BE COVERED WITH A IIN THE TANK OR PUMP BASIN. THE FILTER SHOULD BE INSPECTED EVERY SIX MONTHS. THE EFFLUENT FILTER SHALL BE MAINTAINED AND CLEANED WHEN THE CONSTRUCTED HOUSE �° t!j' ° � TRENCHES MEED COUNTY SETBACK REQUIREMENTS. THE p�TJ1 SYSTEM IS PLUMBED FOR EQOAL PRESSURE DISTRIBUTION LAYER OF FILTER FABRIC. A MINIMUM 4" DEPTH OF TOPSOIL IS TO BE PLACED ABOVE THE BACKFILL TO THE SURFACE, TANK IS PERIODICALLY PUMPED OR AS NECCESSARY INSTALL A SUITABLE �O'' / YY�TH ALTERNATING BED DOST G. 8. EXTENSION ON THE FILTER HANDLE IF NEEDED FOR EASY ACCESS IN RISER. / yyHHE CHAMBERS' IN EACH B ARE INSTALLED AT LEVEL ' PRADE ALL INSTALLATION OF LEACHING CHAMBERS SHALL BE IN CONFORMANCE WITH THE MANUFACTURES INSTALLATION INSTRUCTIONS. 10. THE CONTRACTOR SHALL ENSURE THAT THE SEWER LINES, SEPTIC TANK AND RISERS ARE WATERTIGHT. ALL PLUMBING FIXTURES AND OWS COMPONENTS \ S�, S7 THE QOTTOM ELEVATION OF EACH BED HAS A 9. SHALL BE INSTALLED AND MAINTAINED TO AVOID SURFACE OR GROUNDWATER \ \ \ \ 52,3 `3 2 S�7 / ' MAXIMUM DEP OF 36" INp1ES TO THE TRENCH BOTTOM / THE ABSORPTON TRENCHES/BED OR MOUND MUST BE GENERALLY MARKED AT FROM ENTERING THE SYSTEM AND TO PREVENT LEAKAGE FROM THE SYSTEM. \ \ / 2 , / SURFACE BEL W THE PROPOSED GRADE. THE GRADE BELOW THE SAND LAYER I FILLED LEVEL WITH SUITABLE THE FOUR CORNERS WITH INSPECTION PORTS AND/OR BURIED REBAR. THE FIELDS MUST BE PROTECTED FROM VEHICULAR AND LIVESTOCK TRAFFIC. IN-HOUSE PLUMBING FIXTURES SHALL BE MAINTAINED TO PREVENT EXCESS WATER FROM ENTERING THE SEPTIC SYSTEM. EXCAVATED MATERIAL AND 3• MINUS SANDY PIT RUN 10. \ 6 � THE ASSORPTON FIELD SURFACES MUST BE CROWNED 70 DIVERT \ \ \ 60 / MATERIAL STALLED WITH MINIMUM 12• COVER OVER TP / SURFACE DRAINAGE AWAY FROM THE FIELD. DUPLEX EFFLUENT PUMP &DOSING SYSTEM \ APT TM WITM2A00 GALL I / OF gIAMgERS, \ \ \ �AOPLLED SEGO TAi OREy% \ \ \ \ DUPLEX PUMP IOTUBE VAULT DOSING / � � � 11• THE ENTIRE ABSORPTION FIELD SURFACE MUST BE REVEGATATED. 1. AN ORENCO SYSTEMS BIOTUBE DUPLEX PUMP ASSEMBLY SHALL BE INSTALLED IN THE SECONDARY CHAMBER IN THE 1,500 GALLON SEPTIC ASSEMBLY \ \ \ HE -SE LY I THE SE ARY COMPARTMENT OF / \ \ THE`.SEr�IC�TANK. TANK, IPEGONNECRIONS ` _ / 1 1/2�PVC 40 NDIVIDUAL PRESSURIZED / TESTING, INSPECTIONS AND CONSTRUCTION MANAGEMENT TANK. USE ORENCO PUMPS (MODEL P5005-12DAX2) \ \ \ AND RISERS ARE WATERTI TRAN�p(TYP.) LIN ( ) 1.5• / PRESSUR DISTRIBUTION HEADER ADDITIONAL GEOTECHNICAL EVALUATIONS AND INSPECTIONS BY THE ENGINEER SHOULD BE PERFORMED DURING INITIAL STAGES OF 2. PRESSURIZED DISCHARGE PIPES, AND BIOTUBE PUMP DOSING ASSEMBLY W/ AUTOMATIC CONTROLS AND ALARMS SHALL BE INSTALLED \ \ W/�1.5e TO 25• TEES AT EACH AND EAGLE COUNTY 7O VERIFY ASSUMPTIONS MADE FOR THE OWS DESIGN. COMPONENTS IN THE PUMP VAULT ASSEMBLY. INSTALL WATERTIGHT \ \ REDUCER CONSTRUCTION TO BE EXCAVATED FOR VISUAL RISERS CENTERED OVER THE ACCESS PORTS TO EASILY INSPECT AND INDIVIDUAL FORATION DISTRIBOTION PIPE (Tyw) S ADDITIONAL PROFILE HOLES MAY NEED \ \ \ \ \ /RISER. / / INSPECTION BY THE ENGINEER AND THE COUNTY ENVIRONMENTAL HEALTH PRIOR TO CONSTRUCTION OF THE ABSORPTION FIELDS MAINTAIN SYSTEM COMPONENTS FROM THE SURFACE. USE INSULATED ACCESS LIDS. \ \ \ INSTALLED AW DIAMETER ACCESS SPECIALIST . \ \ SEALED BOLT DOWN TANK ADAPTER, OVER SEPTIC 3. \ \\ TANK SECONDARY CHAMBER AdCESS OPENING �° / 2. THE EVALUATIONS AND INSPECTIONS MAY RESULT IN MODIFICATIONS TO THE INSTALL QUICK DISCONNECT THREADED COUPLERS ON THE PUMP \ \ / \ \ \ FOR ACCESS TO PUMPigSSEMBLY BIO VIBE DESIGN THAT MAY INCLUDE FIELD SIZE REVISIONS AND POSSIBLE SOIL DISCHARGE LINE. EXTEND DISCHARGE LINE UP TO WITHIN 24" OF THE \ \ \ VAULT. RISER HAS INSULATED LID AT THE / \ \ / REPLACEMENT IN SELECT AREAS IF NEEDED. SUFFICIENT NOTICE TO THE NEEDS ACCESS LID TO PROVIDE EASY ACCESS FOR MAINTENANCE OF THE PUMP. \ \\ SURFACE DEPTH TO TOP OF TANK FROM ENGINEER BY THE PROJECT MANAGER/CONTRACTOR TO BE MADE IN \ \ \ \" OSED GRADE IS APPROXIMATLEY 2'. / ORDER TO SCHEDULE THE SITE INSPECTIONS. THE DUAL PUMP DISCHARGE ASSEMBLIES SHALL BE INSTALLED TO \ \ PERMITTED SYSTEM THE ENGINEER SHOULD 4. \ \ \ DUAytL-7l 1/2• PVC SCHD-40 PRESSURE PIPE/ J 3. PRIOR TO CONSTRUCTION OF THE BE DISCHARGE EFFLUENT TO THE DUAL 1.5" PRESSURIZED TRANSPORT LINES. \ \ \ \ TRANSPORT LINES. HIGH POINT INVERT AT TANK tS \ \ / I CONTACTED BY THE PROJECT MANAGER/CONTRACTOR WELL IN ADVANCE TO PROVIDE ADEQUATE TIME TO DISCUSS THE SYSTEM COMPONENTS WITH THE HIGH POINT INVERT OF THE DISTRIBUTION SYSTEM IS AT THE TANK ACCESS RISER. INSTALL ANTI SIPHON ORIFICE IN EACH PUMP'S COLD \ \ ACCESS'`RISER. INSTALLED ANTI SIPHON OI�Fl IN b0 \ \ \ 1'(HE COLD -WETHER PUMP DISCHARGE BLY - / CONTRACTOR, ANSWER QUESTIONS, RESOLVE ANY CONFLICT ISSUES AND WEATHER PUMP DISCHARGE ASSEMBLY PIPE BELOW THE RIM OF THE \ \ PIR€. SCHEDULE INSPECTION SITE VISITS BASED ON CONSTRUCTION PROGRESS. BIO -TUBE VAULT AT A LEVEL ABOVE THE MAXIMUM TANK LIQUID LEVEL. 4, COUNTY REGULATIONS REQUIRE THAT THE DESIGN ENGINEERS OF RECORD PERFORM SITE INSPECTIONS OF THE PERMITTED SYSTEM DURING CONSTRUCTION 5. THE DOSING VOLUME SHALL BE 70-80 GALLONS PER DOSING CYCLE. AND PROVIDE "AS -BUILT" DOCUMENTATION OF THE INSTALLED SYSTEM 70 THE THE APPROXIMATE DRAWDOWN IN THE TANK IS 4". THE DUPLEX PUMP \ \ \ \ /� COUNTY AFTER CONSTRUCTION IS COMPLETE. THE REGULATIONS FURTHER SYSTEM WILL ALTERNATE DOSES FROM EACH PUMP. THE EFFLUNT FROM \ \ \ \ / 1.25• PVC SCHD-40 PERFORATED DISTRIBUTION PRESSURE REQUIRE SITE INSPECTIONS AND APPROVAL BY THE COUNTY ENVIRONMENTAL EACH DOSING CYCLE WILL ALTERNATE BETWEEN EACH BED. PIPE LATERALS DRILLED 3/16. ORIFICES IN 1.25" PIPE AT HEALTH DEPARTMENT OF THE EXPOSED COMPONENTS OF THE SYSTEM PRIOR TO 2.5 SPACING. INSTALLED PRESSURE HEADER PIPE TEES BACKFILLING. THEREFORE THE COUNTY ENVIRONMENTAL HEALTH DEPARTMENT 6. INSTALL PUMPS ASSEMBLIES, RISERS, ELECTRICAL SYSTEMS, FLOATS AND \ THROUGH THE KNOCKOUT HOLE AT THE BOTTOM OF THE SHOULD ALSO BE CONTACTED AND NOTIFIED OF THE CONSTRUCTION SCHEDULE. DISCHARGE LINE PER MANUFACTURES INSTALLATION GUIDELINES. USE AN HEAD CHAMBERS AND LAID PIPE ON THE TOP SURFACE OF ORENCO SYSTEMS MODEL P3005. THE SYSTEM SHALL BE INSPECTED BY THE SAND FILTER LAYER OVER THE ENTIRE LENGTH OF THE 5. CONTRACTOR SHOULD DISCUSS ISSUES REGARDING SPECIFICATIONS, INSTALLATION A QUALIFIED TECHNITION EVERY SIX MONTHS. LAYOUT OF TREATMENT BEDS AND SOIL >>. LAYOUTOF TRENCH. ORIENT ORIFICES BETWEEN THE FIRST AND LAST AND OPERATION OF OWS MECHANICAL SYSTEMS AND CONTROLS WITH THE WERE INSPECTED AND APPROVED BY TO SPRAY UPWARD (12 O'CLOCK) AGAINST INTERIOR OF MANUFACTURERS REPRESENTATIVE AND/OR THE ENGINEER. 7. ALL INSTALLATION AND MAINTENANCE SHALL BE PERFORMED BY A THE ENGINEER PRIOR TO INSTALLATION OF CHAMBERS. EXTENDED TO INSPECTION PORT OF END QUALIFIED PERSON IN ACCORDANCE WITH THE INSTALLATION & COMPONENTS CHAMBERS AND CAPPED ENDS OF DISTRIBUTION PIPE W/ 6. OUR DESIGN AND RECOMMENDATIONS ARE BASED UPON INFORMATION SUPPLIED MAINTENANCE GUIDELINES FOR THE ORENCO SYSTEMS BIO -TUBE VAULT BALL VALVE CENTERED UNDER INSPECTION PORT TO ALLOW TO US BY OTHERS. IF SUBSURFACE OR SITE CONDITIONS ARE FOUND TO BE FROM CONDITIONS ASSUMED OR INDICATED, WE SHOULD BE NOTIFIED PUMP ASSEMBLY. FLUSHING OF PIPE. STABILIZE PIPE TO PREVENT PIPE DIFFERENT ROTATION MOVEMENT. DRILLED FIRST AND LAST 3/16• TO EVALUATE ANY EFFECT ON THE PROPOSED OWS. IF THE COUNTY ORIFICES ORIENTED DOWNWARD AT BOTH ENDS OF TO ENVIRONMENTHIS DESIGNTAWEHEALTH SHOULD BE CONTACTED PARTMENT TTO EVALUATE AND RESPOND TOESTS CHANGES OR THE DISTRIBUTION LATERAL TO ALLOW DRAINAGE OF OUT OF TRIBU PUMP ASSEMBLIES ELECTRICAL NOTES (TYPICAL DUPLEXU ) PIPE INSTALLED ORIFICE SHEILDS BELOW DRAIN ORIFICES REQUEST. TO PREVENT EROSION OF MEDIA SURFACE (TYP. EA 7. CONTRACTOR SHOULD REVIEW ANY CONDITIONS ON THE ISSUED PERMIT AND 1. AN ORENCO SYSTEMS PUMP CONTROL PANEL SHALL BE INSTALLED BY A / TRENCH) COORDINATE WITH THE ENGINEER REGARDING CONSTRUCTION OF THE SYSTEM. QUALIFIED INSTALLER IN COORDINATION WITH THE ELECTRICIAN. WE RECOMMEND 230 VOLT ELECTRIC SERVICE BE PROVIDED TO THE PUMPS. \ 8• IF YOU HAVE ANY QUESTION OR NEED ANY ADDITIONAL INFORMATION, PLEASE THE POWER SUPPLY FOR THE PUMPS AND CONTROLS HALL CONSIST OF 20CIRCUITS FOR 10 AMP CIRCUIT ANDDISCONNECT BUILDING ENVELOPE \ / CALL. C(2) PROVIDE LINE OFESITEMPS NTH CONTROL OOR X. 2. THE ELECTRICIAN OR QUALIFIED INSTALLER SHALL INSTALL ELECTRICAL WIRES IN CONDUIT FROM THE CONTROL PANEL TO THE PUMP ASSEMBLY NATIVE COVER VEGETATION, SOD OR COORDINATE INSTALLATION W/ JUNCTION BOX IN THE RISER OVER THE PUMP BASIN. INSTALL COLOR CODED WIRES PER CONTROL PANEL DIAGRAM. INSTALL GAUGE CROWN FIELD 70 OTHER SUITABLE VEGETATIVE COVER SHED SURFACE WATER SCC ENTERPRISES, INC. U S WIRES FOR CONTROLS AND (5) 10 GAUGE WIRES FOR PUMPS WITH 70PSOI 4" MIN. 1.25" SCHD-40 CUSTOM PERFORATED P.O. BOX 913 CONDUIT SEAL NEAR RISER SPLICE BOX. ELECTRIAN TO COORDINATE FILTER FABRIC PVC DISTRIBUTION LATERAL PIPE SILT, CO 81652 INSTALL INSULATED LID, W/INSTALLER. MIRAFI N-140 OFFICE.- 970-876-2057 \ FAX. 970-876-2360 TYPICALPED FACE 12"MIN. � with Groin R AGGREATE AVEDASURFACE (reoomrr MOUND EMBANKMENT MATERIAL TO BE COMPACTED TO 65% STNPROCTOR DENSITY wKl d ad�heeil}8)MIUI EXISTING GRADE 1( \ Slope �� I Gasloeted Lid with Away from Riser winless Steel Bolla r R` SELECT BACK FILL 3:1 SIDE SLOPE NATIVE SOIL SCREENED \ (TIP. AROUND PERIMETER) w h �d � ` ` ` ���\\�/A , �'° c �_ TO 3" MINUS OR 3' \ MIN 4" TOPSOIL MINUS PIT RUN MATERIAL \ SELECT SOIL REPLACEMENT AS Condufl to Control Panel Effluerd Discharge 6" MIN. EXCAVATED MATERIAL COMPACTED TO 907 STANDARD PROCTOR 3 \ NEEDED TO LEVEL FIELDS WITH.c� QUICK -4 SUITABLE NATIVE MATERIAL OR ConduR Seal Tank Ada Cast or bolted m°ef \ IMPORT PIT RUN, SAND W/ GRAVELS INFILTRATOR \ MEASURE DEPTH OF FLOATS FROM TOP rl 4" SUITABLE BACKFILL OR CLASS 6 ROAD _�-ilj BASE f�i STONAL_� SAND FILTER MEDIA LAYER OF y5f2" EQUALETO TOPOOFTANK LIDSEMBLY \\/ I/' 4" ��T}ra+a COARSE 70 MEDIUM SAND \ 18 Level Control 4\ COMPACT AND LEVEL SURFACE \ i I Root ASsernbly UNDISTURBED EARTH NOTE: ALL CHAMBER ROWS IN THE BEDS MUST BE LEVEL. NATIVE SOIL Vault Inlet Ports TRENCH CROSS- SECTION FOR NO. DA T1 REVISION BY DEPTH OF BEDS (BOTTOM OF SAND LAYER) TO BE INSTALLED Flow Inducer (2) OVER A MINIMUM 2' OF NATIVE SOIL OR SUITABLE IMPORT SDR -35,26 OR HDPE OFF CHATEAU WAY MATERIAL END PLATES ARE TO BE INSTALLED ON THE END OSI Effluerd PumpSHIELD-0-MESA, _PIPES PITA7N COUNTY, CO CHAMBERS IN EACH ROW. INSTALL 1.25" PERFORATED PIPE N.T.S. ALONG THE ENTIRE LENGTH OF EACH ROW OF CHAMBERS. Drain Port JEMM ��� PIPE TO BE INSTALLED ALONG THE BOTTOM SURFACE OF THE BED WITH THE ORIFICES POINTED UPWARD. INSTALL A 4" Filter Cartridge VERTICAL INSPECTION RISER FROM THE CENTER CUT OUT ON BiotubsO Pump Vault AS -BUILT ONSITE WASTEWATER SYSTEM THE TOP OF THE LAST CHAMBER IN EACH ROW. INSTALL A SITE PLAN AND SYSTEM DETAILS VALVE AT THE END OF THE DISTRIBUTION LATERALS, SOPRIS ENGINEERING, Lw. FROM THE INSPECTION PORT TO ALLOW FLUSHING OF THE LINE. THE VALVE IS CLOSED FOR NORMAL OPERATION. CIVIL CONSULTANT Duplex Effluent Pumping System - 2nd Compartment Drawdown 502 MAIN STREET, SUITE A3 DES. PER CKYTN FILE N0. CROSS-SECTION STANDARD CAPACITY rSHEETI CHAMBER SYSTEM CARBONDALE, CO 81623 2508$.01LEACHING 25093.0} P5093 -CWS -DNC 5-}9-05 (970) 704-0311 DR PER DATE 12-21-06 F :.NOT TO SCALE