HomeMy WebLinkAboutpitkin.eh.264916102005 (2005)Pitki ounty Environmental Health Departr. ,t
Permit for an Individual Sewage Disposal System
0405 Castle Creek Road, Suite 10, Aspen, Colorado 81611
Phone 970-920-5070 / FAX 970-920-5077
Permit # 05021 Parcel ID # 2649-161-02-005
Type of permit New Repair(x) Addition/Remodel to House( )
Name of Owner Judi and Medford Leake
Street Address 0357 Crystal Lane
Property legal description Crystal River Country Estates
Size of lot 2.04 acres Total square footage of the house 3069 sq ft
Water source Private well
# of bedrooms in house 3 # of offices, lofts & similar sized rooms in house
Caretaker unit Total square footage of the caretaker unit
# of bedrooms in caretaker unit # of offices, lofts & similar sized rooms in caretaker unit
Designed for what # rooms (list) 3 bedrooms
Permit information
Designed by All Service Septic
Mailing Address PO Box 2844, Glenwood Springs, CO 81602
Perc rate 25 mpi Profile hole depth 8 ft Depth to groundwater or bedrock Greater than 8 ft
Minimum Septic tank capacity 1312 gallons Minimum Absorption area 525 sq ft w/ 50% reduction
Comments
Septic permit approved per compliance with the engineer design and specifications dated May 10, 2005. Any
changes must be approved by this department and the design engineerrp for to them being made.
Minimum horizontal distances between components of the system and physical features shall conform to the Pitkin
County ISDS regulations. There must be at least a 29 foot separation between the field and the dry gulch.
This system will consist of the existing 1250 gallon tank with an effluent filter on the outlet followed by a 500 gallon
pump chamber. The effluent will be pumped to a distribution box and the effluent distributed to three trenches,
each having 18 Quick 4 chambers in each for a total of 54 Quick 4 chambers. There must be at least 6 feet of
separation between each trench.
This department does not, endorse any brand of products. This permit must be kept on-site during installation.
The engineer must do a final inspection of the installation and submit an as -built letter to this department. This
department must also be called for an inspection with a minimum of 48 hours advanced notice.
*Revegetation over the area of the field is very important for the functioning of the system. Pitkin County has guidelines that must be
followed to assure the plants that are introduced are appropriate for the conditions of the area. The use of native plants is strongly
encou
Permit approved by: M � A P4, c (f` Date: �1 IF, �Z
Plans and specifications of the proposed individual sewage disposal system have been reviewed and are considered
satisfactory. Permission is hereby granted to the owner or the agent to perform the work indicated in accordance with the Pitkin
County ISDS Regulation in effect at the time of issue. This permit becomes invalid 6 months from the date that the permit was
issued unless system construction has commenced or an extension has been approved in writing by the Department.
As -built drawings must be im; uded with this permit before the final approval will be issued.
Installer: 01(,11 ' k0n�r"A h nn,
Final approval:
Date:
kk j ctka -i fic i�
E
PITKIN COUNTY ENVIRONMENTAL HEALTH & NATURAL RESOURCES
DATE:'? 1 —7 (a
Send to: Ak
&L rl"
��vi
Attention:
Office Location:
Fax Number: -- ' CH •— O j�:�
From: A �kk
,G c—
Office Location:
Phone Number: — S� 4% —7
Number of Pages, Including Cover:
❑ URGENT ❑ REPLY ASAP ❑ PLEASE COMMENT ❑ PLEASE REVIEW ®'FOR YOUR INFORMATION
COMMENTS:
V - � -oa -
C),
Pitkin County Environmental Health and Natural Resources
0405 Castle Creek Road, Aspen, CO 81611
Phone(970)920.5070 1 Fax(970)920.5077
Web site www.aspenpitkin.com/depts/12/
Mai 17 05 08:23a Pitkin Co Env. Health (970)920-5077
PITKIN COUNTY ENVIRONMENTAL HEALTH DEPARTMENT
APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM
0405 Castle Creek Road, Suite 10, Aspen Colorado 81611
Phone (970) 920-5070 Fax (970) 920-5077
Name of OWNER '-�lt4d (, a,c( �/f�CIL(-� �� L )-C&/e
Owner's Mailing Address 0,57 -7 L t S' ( L ao Z
City, State, Zip C L\ Business Phone: %�` (— Ot{O.3
Home Phone: �c7 <(- O -2 5 `{ E-mail Address: - 6 12 Q Ke g Q!J (, co &x
Primary Contract Person (all communication regarding this permit will go through this person)
Name L eaI��
Company
Contact Mailing A//dd��ress 35'? Lr-S'i`d ( � ati e
city, State, Zi �._CLY H &, J. t e p ? ((p 13 Business Phone : 76 q— a46Q 3
Cell Phone: 5 '7 q-- S 3 dy Fax: -?614— C !S 33 E-mail Address: 4;- 5a ,-rs. ✓1e-tr'
Parcel ID # (available from assessor's oince
at 920-5160 or at www.pitkinassessor.orq) (�. C _ L C . L `D
Street address of property 35-7 L zV e
Legal Description: Lot Block Filing ,Subdivision Cf 5-�r- (�
Size of lot: 01 . lJ {^ acres. Type of proposed structure: Se
Total square feet of house 36 62
# of bedrooms (potential) in house _
Caretaker Unit: Attached ( ) Detached (n )
Total areas . ft. of caretaker unit t4 I rc # of bedrooms(potential) in caretaker unit
Permit is for: New Home ( ) Repair due to failure ( ✓) Remodel/Addition ( ) Emergency use ( }
Water: Private well ( i -I Spring ( } Stream ( ) Community/Public Water System ( )
If community system: Name of system
The fee for a ISDS application is $600 for a permit that takes 6 hours or less for the department to approve. If approval takes
longer than 6 hours, a nate of $100 per hour will be charged. The maximum fee is $1000. The basic fee of $600 is due at the
time of application. The remainder, if any, will be due in two stages: first, at the time of issuance of the ISDS permit: second,
before final approval of the ISDS permit.
Application for an individual sewage disposal system is hereby submitted. I hereby certify that the above information is true and
accurate and that I have provided true and accurate information on locations of all existing and proposed wells, contour
intervals, buildings, property lines, ditches, slopes, waterlines, springs, suction or irrigation lines, drinking water cistems, drain
tiles, irrigation ditches, lakes, water courses, streams, floodplains, dry gulches, and existing septic systems. I hereby certify
that any such features not shown on attached site map are not present. Issuance of the permit does not imply the approval of
any other permit required for construction pursuant to Pitkin County codes. No construction may be undertaken until all
approvals and permits have been obtained.
The Pitkin County Envin)nmental Health Department, Pitkin County and employees of these agencies will be held harmless
should the individual sewage disposal system fail or malfunction. The permit to construct is issued on information submitted by
the applicant or his/her representatives. The owner assumes full responsibility in case of failure of the system.
Signature of applicant/ Date 4
8 S
Received by (V 1� j Receipt # ( o Date
G:\isdsVsds appliclisdsapp Rev050103.doc
P.3
4L �•`
PO Box 2844
Gill *n,4 1111
SEBY�CE Ph97"18.5033
L fax 303-216-2796
June 1, 2005 Project No. 1075
Judy Leake
0357 Crystal Lane
Carbondale, Colorado 81623
Installation Observation, Leake Residence
0357 Crystal Lane
Pitkin County, Colorado
Judy Leake,
ALL SERVICE septic, LLC performed an installation observation on May 24, 2005 for the subject
property.
The installation included the existing 1250 -gallon septic tank, followed by a 1000 -gallon, two-
compartment precast concrete septic tank with a BiotubeTM pump vault in the second compartment.
The drain field consisted of 4 rows of 13 to 14 gravelless chambers, for a total of 54 chambers, and
533 square feet of infiltrative area. A concrete distribution box was installed to distribute effluent. An
as -built drawing is included.
The 45 -foot separation from the 1000 -gallon septic tank to the river is acceptable.
The OWS was installed according to specifications. This observation is not a guarantee of
workmanship and/or parts and materials. ALL SERVICE septic, LLC should be notified if changes
are made to the OWS.
Please call with questions.
Sincerely,
0
ALL SERVICE septic, LLC Reviewed By: "-!W Teo
U
• �eir
Timothy R. Petz Richard H. Petz,� • '
I E�►�0�
2 copies sent
Copy to Pitkin County Department of Health and Environment, Attn: Carla
AS BUILT DRAW
Z
i
Q� 1000 GALLON,8EPTIC TANK
AND PUMP CHAMBER
�Q
tl
533 SF OF C
TRENCHES
CHAMBERS
'QUICK-4'Cl
1250 -GALLON SEPTIC TANK WITH EFFLUENT
FILTER _ _ .
SCALE /
1"=20'
NORTH /
\ 29' SETBACK vuvL_Ixvn i 1 1 r it w ,
,
i
I
i
DONCRETE
ION BOX.
0357 CRYSTAL LANE / ALL "r._11No. 1075
Qr=P\/1(' F QFPTIC`� _ \_— _
i • S :�.. w
tie i x `'� til •�/.F {iy�
*4'!Z': ,.:v. .,44`.. 's:: - -_r-�r r •0iG
Pitkin County Environmental Health
PO Box 2844
Glenwood Springs, CO 81602
Ph 970-618-5033
Fax 303-216-2796
May 10, 2005
Judy Leake
0357 Crystal Lane
Carbondale, Colorado 81623
Project No. 1075
Subsurface Investigation and Repair Onsite Wastewater System Design, Existing Residence
0357 Crystal Lane
Pitkin County, Colorado
Judy Leake,
ALL SERVICE septic, LLC performed a percolation test and a repair onsite wastewater system
(OWS) design for the subject residence. The property is located near the Town of Redstone, in an
area where OWS and wells are necessary. This letter is to be used in conjunction with plans provided.
SITE CONDITIONS
There is an existing 3 -bedroom residence at the subject residence. The present drain field has been
experiencing problems and will be abandoned. The existing septic tank is in good condition and may
be incorporated into new OWS. All other components of OWS should be replaced.
SUBSURFACE
The subsurface was investigated by excavating an 8 -foot test pit near the proposed drain field location as
shown on attached plans. Three percolation holes were dug. The test pit indicated the site has a 1 -foot
root zone, underlain by slightly clayey, silty sand with scattered cobbles, to the maximum depth
explored of 8 feet. Groundwater or bedrock was not encountered. Percolation rates ranged from 20 to
27 minutes per inch (MPI). A 25 MPI rate will be used to design the OWS.
DESIGN SPECIFICATIONS
The OWS design is based on 3 -bedrooms and an average sewage load of 600 GPD. The installation
must include the existing 1250 -gallon two-compartment septic tank with an effluent filter, followed
by a 500 -gallon, single -compartment, precast concrete tank with a pump. Tank alternatives may be
considered. Three gravelless chamber trenches must be installed as indicated on plans provided.
Three rows of 18 `Quick 4' chambers, for a total of 54 chambers, and 533 square feet (SF) of
infiltrative area, is required. A distribution box should be used to distribute effluent. Construction
must be according to the county ISDS regulations, the septic permit provided by Pitkin County
Environmental Health Department, and this design.
Repair OWS Design
Project No. 1075
5110105
Page 2
OPERATION INFORMATION AND MAINTENANCE
The surface of the drain field should be seeded upon completion. Vegetation is an important factor in
drain field performance. Geo -fabrics or plastics should not be used over the drain field. Livestock
should not graze on the drain field. Plumbing fixtures should be checked to ensure that no additional
water is being discharged to OWS. For Example, a running toilet or leaky faucet can discharge
hundreds of gallons of water a day and harm a drain field.
The homeowner should pump the septic tank every two years and clean the effluent filter as needed.
Garbage disposal use should be minimized, and non -biodegradable materials should not be placed
into the OWS. Grease should not be placed in household drains. Loading from a water softener
should not be discharged into the OWS. No hazardous wastes should be directed into the OWS.
Mechanical room drains should not discharge into the OWS. The OWS is engineered for domestic
waste only.
ADDITIONAL CONSTRUCTION NOTES
If design includes a pump, air release valves and weep holes should be installed to allow pump lines
to drain to minimize risk of freezing. Extensions should be placed on all septic tank components to
allow access to them from existing grade. Precast concrete tanks and distribution boxes should be
used, unless plastic or fiberglass is required. Access to all tank compartments and distribution devices
is optimal.
INSTALLATION OBSERVATIONS
ALL SERVICE septic, LLC, and the county must view the OWS during construction. The OWS
observation should be performed before backfill, after placement of chambers and distribution pipes.
Septic tanks, distribution devices, pumps, dosing siphons, and other plumbing, as applicable, must
also be observed. ALL SERVICE septic, LLC should be notified 48 hours in advance to observe the
installation.
LIMITS:
The design is based on information submitted. If soil conditions encountered are different from
conditions described in report, ALL SERVICE septic, LLC should be notified. All OWS construction
must be according to the county regulations. Requirements not specified in this report must follow
county regulations. The installer should have documented and demonstrated knowledge of the
requirements and regulations of the county in which they are working.
Please call with questions.
ALL SERVICE septic, LLC
Timothy R. Petz
3 copies sent
Reviewed By;
PITKIN COUNTY ENVIRONMENTAL HEALTH DEPARTMENT
Percolation Test and Soils Data Form - TABLE 1 - PROJECT 1075
PROFILE PIT Date of Test: 5-4-05
0 - 1' Topsoil, Root Zone, Sandy
1'- 8' Sand, Clayey,Silty, Cobbles, Dense, Moist, Red/Brown
Colluvium
No Groundwater or Bedrock was Encountered
Hole Hole Depth Interval (min.)
No. (in.)
Measurement at
Start of Interval in.
Measurement at
End of Interval in.
Change (in.) Percolation Rate
min./in. MPI
1 34 20
3.50
5.00
1.50
20
5.00
6.25
1.25
20
6.25
7.25
1.00
20
7.25
8.00
0.75 27
20
8.00
9.00
1.00
20
9.00
10.00
1.00
2 30 20
2.50
4.00
1.50
20
4.00
5.50
1.50
20
5.50
6.50
1.00 20
20
6.50
7.75
1.25
20
7.75
9.00
1.25
fill 20
3.50
5.00
1.50
3 38 20
3.50
5.00
1.50
20
5.00
5.75
0.75
20
5.75
7.00
1.25
20
7.00
8.25
1.25
20
8.25
9.00
0.75 27
fill 20
4.25
5.25
1.00
AVG = 25 MPI
PITKIN ENVIRONMENTAL HEALTH DEPARTMEN i
ISDS DESIGN CALCULATIONS
Owner's Name Parcel ID #
House Size (sq. ft.) L (75 gpd, 100 gpd, or 130 gpd)
Number of Bedrooms in Main House
Number of Offices, Libraries, Studies, Similar -sized Rooms in Main House
Number of Bedrooms in Detached Caretaker unit
Number of Offices, Studies, Similar -sized Rooms in Caretaker Unit
(If the caretaker unit is ATTACHED, treat as if part of main house.)
Average Daily Waste Flow 600
State Review Required? no
Perc Rate (T)
Design Flow (Q) = # potential bedrooms X 2 people/bedroom X gpd X 1.75
Q= 1050
Minimum tank capacity 1312.5 gallons
Absorption Area (=Q/ 5 X SQRT perc rate)
A = 1050 sq. ft. of absorption area required
68 gravelless chamber units without reduction
# of Perc Holes Required: 3
1 in every soil type? Spaced uniformly over proposed area?
QUICK 4 9_8
A = 525 sq.ft. with 50% reductionTRENCHES
I gravelless chamber units with reduction
STANDARD
A= 525 sq.ft. with 50% reductionTRENCHES
34 gravelless chamber units with reduction
EQ 36
33 EQ36 units in TRENCHES
SETBACK FROM WELL
# of feet = 104
SETBACK FROM POND, STREAM OR IRRIGATION DITCH
# of feet = 54
SETBACK FROM DRY GULCH
# of feet = 29
100
QUICK 4 9.2
735 sq ft 30% reduction BED
80 chamber units with reduc.
735 sq ft 30% reduction BED
I chamber units with reduc.
�, � EQ36 units in a BED
Tim Petz, 03:31 PM 5/9/2005 , Re: Leake Residence Test Pit Ready Page 1 of 2
auth-sender: timpetz@mail2tim.com
thread -index: AcVU5ueNsOJi18EOQN+g97DGZ2X/Aw=
Thread -Topic: Leake Residence Test Pit Ready
From: "Tim Petz" <timpetz@mail2tim.com>
To: <carlab@ci.aspen.co.us>
Subject. Re: Leake Residence Test Pit Ready
Date: Mon, 9 May 2005 15:31:55 -0700
X -Mailer: Microsoft CDO for Exchange 2000
Importance: normal
Priority: normal
X-OriginalArrivalTirne: 09 May 2005 22:31:55.0590 (UTC) FILETIME=[E7AB4660:O1C554E6]
X -Spam: [F=0.0003447298; B=0.500(0); BMI=0.500(none); 5=0.010(2005042701); MH=0.300
(2005050904); R=0.073(s55/n694); SC=none]
X -MAIL -FROM: <timpetz@mail2tim.com>
X -SOURCE -IP: [66.28.189.48]
X-MailScanner-Information: Please contact the ISP for more information
X-MailScanner: Found to be clean
Ya, the existing is out back, it is surfacing. Next to the river too. Tomorrow am is great. I will be around
on tues if you have questions. just call. thanks heaps.
><-----Original Message----->
>From: Carla Block
>Sent: 5/9/2005 4:37:46 PM
>To: timpetz@mail2tim.com
>Subject: Re: Leake Residence Test Pit Ready
>Judy is my vet - sort of. I deal with her from time to time.
>I don't know when ][ can get up to Redstone.
>How about tomorrow am? It is the only day I can do it outside of
>Friday. Is it REALLY failing?
>Thanks,
>carla
>At 02:39 PM 5/9/2005 , you wrote:
>>Contact : Judy Leake 704-0533
>>Address : 0357 Crystal Lane
>>Directions : Go about 1 mile past the "Redstone 9" sign, and go left over
>>bridge that says "Crystal River Country Estates". Take immediate right and
>>follow road along river. The road will curve left and go up hill, take a
>>quick right into drive that is marked with address.
>>Test pit and peres in the side yard.
>>This will be an upgrade, the system is failing. I am trying to rush this
>>one due to proximity to river. Thanks tons!
Printed for Carla Block <carlab@ci.aspen.co.us> 5/9/2005
Tim Petz, 02:39 PM 5/9/2005 , Leake Residence Test Pit Ready Page 1 of 1
auth-sender: timpetz@mail2tim.com
thread -index: AcVU34ePQKr1EA1wQZSzVndYyPpg8w==
Thread -Topic: Leake Residence Test Pit Ready
From: "Tim Petz" <timpetz@mail2tim.com>
To: <carlab@ci.aspen.co.us>
Subject: Leake Residence Test Pit Ready
Date: Mon, 9 May 2005 14:39:07 -0700
X -Mailer: Microsoft CDO for Exchange 2000
Importance: normal
Priority: normal
X-OriginalArrivalTime: 09 May 2005 21:39:09.0543 (UTC) FILETIME=[888ED770:OIC554DF]
X -Spam: [F=0.0008039999; B=0.500(0); BMI=0.500(none); S=0.010(2005042701); MH=0.500
(2005050904); R=0.073(s55/n694); SC=none]
X -MAIL -FROM: <tiinpetz@mail2tim.com>
X -SOURCE -IP: [66.28.189.48]
X-MailScanner-Information: Please contact the ISP for more information
X-MailScanner: Found to be clean
Contact: Judy Leake 704-0533
Address: 0357 Crystal Lane
Directions: Go about 1 mile past the "Redstone 9" sign, and go left over bridge that says "Crystal River
Country Estates". Take immediate right and follow road along river. The road will curve left and go up
hill, take a quick right into drive that is marked with address.
Test pit and peres in the side yard.
This will be an upgrade, the system is failing. I am trying to rush this one due to proximity to ever.
Thanks tons!
Tim R Petz
ALL SERVICE septic, LLC
Onsite Wastewater Systems
970-618-5033
303-908-7823
Printed for Carla Block <carlab@ci.aspen.co.us> 5/9/2005
Nov 11 20 12:06p p•4
i t:� ter►. ����,� -�`� w�.
C-oN-V A C.T
C.� -1 A>. Tzoji . 0Q"IV-*q
O35 CR�fbTAL t_ANO
I'S 3(S5 uJ
SI&A TART
5MEO
jima@co.pitkin.co.us, nancyb@co.pitkin.co.us, barbarac@co.pitkin.co.us, Leake deck 0037 Crystal Lane
To: jima@co.pitkin.co.us, nancyb@co.pitkin.co.us, barbarac@co.pitkin.co.us
From: Nancy MacKenzie <nancym@co.pitkin.co.us>
Subject: Leake deck 0037 Crystal Lane
Cc:
Bcc:
Attached:
Okay to issue the building permit. The new deck does not block access to the septic tank.
Printed for Nancy MacKenzie <nancym@co.pitkin.co.us>
Jun 15 04 02:16p David C. Ritchie
1-970-963-4330 p.1
0
FAX TRANSMITTAL
Date: (e, -1 : - o `-{
To: AJ AN GN OK cA4ZLA-
EN V. LkcAt'rp SOP E'c r 9-,,1 TS
From: , A.,r ;P,1 i-r-rh E
RECEIVED
JUN 1 5 M4
PITKIN iC ul+I
ENWRONMENTNI. N AI
From: FAX # 970.963.4330
Of: P1'T'e o C✓ DD
V . 0-t, l' 1H-
Of: David Ritchie & Associates, Inc.
Transmitting.-- pages, including cover sheet.
Jf there was any difficulty in transmittal or legibility, please can 970.963.4335.
The information in this transmittal is intended for the named party only. if you have received this
tax in error please respect the confidentiality of addressee and notify sender. Thank you.
wpdnralonno rd ofticefforms/f'1X OOC
DAVID RITCHIE & ASSOCIATES, iNC.
201 Main Street. Suite 201
Carbondale. Colorado 61623
970.963.4335 970.963.4330 fax
dritchieewpris.net
77 4a47'49Ckf
A,07 �t
Jun 15 04 02:16p David C. Ritchie 1-970-963-4330 p.2
,...,
%„ool
b
f �
m
W
X Cl
O �
9
llvOtt
I
n `
N [.j
w
N 7.W
W
b U Ucv LQ
x E- w w 7...
.Ur acn Ow ao W
0 �
Hoz �
mF
0 w o a U " o.
c�
W X T.
W MCL
o a� w ]
;. o �t w o cr. vi o
w
m o v�ito-tea -r p�
CL, m
09
1
1
ti
4
%�3
r
tZ
t A
C
O
r
Wo LL'
F�
U�
:L a
E�
0 o
� — i -, r� 'r i � e
�� 1 iJ.
APPROXIMATE LOCATION OF EXISTING 1000 SF
DRAIN FIELD (TO BE ABANDONED)
LOCATION OF EXISTING 1250 -GALLON SEPTIC
TANK (EFFLUENT SCREEN TO BE ADDED)
'4S EXISTING
WI`t I
f
f
a
60
0357 CRYSTAL LAME
Project NO. 107
PO BOX GLENWOOD
GLEN SPRINGS,
PITKIN COUNTY, COLORADO
REPAIR ONSITE WASTEWATER SYSTEM DESIGN
5-10-05
8-5033
970-618-5033
�
t
i
t
1
1
�
�
1�
r
rj
1
I
APPROXIMATE LOCATION OF EXISTING 1000 SF
DRAIN FIELD (TO BE ABANDONED)
LOCATION OF EXISTING 1250 -GALLON SEPTIC
TANK (EFFLUENT SCREEN TO BE ADDED)
'4S EXISTING
WI`t I
f
f
a
60
u
SCALE
1"=20'
NORTH
�'10 ` fl
Effluent Pumping System - Law Head Pump - 500 gallon 0
Orenco Systems®
1�qxwaw
814 WWAY AVENUE
SU111E"' aRSM
97474-9012
Inspection Access
Riser and Lid (al
or near ground
surface), optional
Tank Adapter —
(cost or boded)
Inlet Tee
PUMP SPECIFICATIONS - PUMP MUST BE
CAPABLE OF:
GALLONS PER MINUTE = 28
DYNAMIC HEAD = 38.5
2" PVC PUMP"
LINE $Q o
AIR RELEASE AT HIGH
POINT IN PUMP LINE
CHAMBER W ,
SHOUEs O'FILE i W
LD�
FOLLOW PIT 0,
TOPOGRAPHY
533 SF OF CHAMBER TRENCHES
TRENCHES = 3
9 OUTLET CONCRETE
DISTRIBUTION BOX, THE BOX r
SHOULD BE MARKED/LOCATED
FOR FUTURE USE, OR
BROUGHT TO GRADE
�► CHAMBERS PER TRENCH = 18
�'► 'QUICK -4' CHAMBERS = 54
f
29' SETBACK
ti
"fir►
�iguid
TANK SPECIFICATIONS
CAPACITY REQUIRED = q X 1.75 X (30 HOURS/24 HOURS) =1312
GALLONS
REQUIRED TANK = 1250 EXISTING WITH EFFLUENT FILTER,
FOLLOW BY NEW 500 GALLON PUMP, CHAMBER
CROSS SECTION OF TYPICAL CHAMBER -TRENCHES
-+ 4" PVC
OBERVATION
PIPE
4,0' MAX
LIMIT OF EXCAVATION
GRAVELLESS
CHAMBER
6' MINS--+
SCARIFY
SURFACE
INFILTRATOR(R) GUICK4(TM) CUT SHEET
48"
EFFECTIVE LENGTH)
TRENCHES
MUST BE
LEVEL
1,5' MIN
Slope Ground
Away from Riser
Conduit to
Control Panel
-.-
-PVC Splice Box
with Cord Grips
-Fiberglass Gasketed lid with
Stainless Steel Bolts
-PVC Riser with Grommet(s)
(bond to tank adapter with
recommended adhesive)
-Discharge Assembly
-Flexible Hose
Effluent Discharge
P—Tank Adapter (cast or bolted)
Level Control
noot Assembly
Check Valve (optional)
Pump
Block
InITI ONE,
(54.1) 459--1449
FAMM E:
(541) 459-2884
DESIGN
THREE - BEDROOM RESIDENCE, <6000 SF = 600 GALLONS PER DAY
TOTAL LOADING = q = 600 GALLONS PER DAY
PERCOLATION RATE = 25 MINUTES PER INCH
CALCULATED AREA = (1.75 X q X sgrt 15) / 5 = 1050 SF
REDUCTION OF 50% 525 SF
TRENCH SPECIFICATIONS
WIDTH OF TRENCHES = 3 FEET =1 CHAMBER
LENGTH OF TRENCHES = 72 FEET = 18 CHAMBERS
TOTAL NUMBER OF'QUICKA' CHAMBERS=44
TOTAL INFILTRATIVE AREA = 533 SF
Tf IREE TOTAL TRENCHES
NOTES:
TRE=NCHES MUST BE ANGLED TO FIT TOPOGRAPHY
AND TO MINIMIZE REMOVAL OF TREES.
THE SLOPE AT THE PROPOSED DRAIN FIELD IS
APPROXIMATELY 10% TO THE WEST. VEGETATION
CONSISTS OF A FULL COVER OF NATIVE GRASSES WITH
SURROUNDING TREES.
LIMITATIONS - THESE PLANS MUST BE USED IN CONJUNCTION
WITH LETTER AND SOILS DATA FORM PROVIDED. THE DESIGN
IS BASED UPON INFORMATIONSUBMITTED. IF SOIL
CONDITIONS ENCOUNTERED ARE DIFFERENT FROM
CONDITIONS DESCRIBED IN REPORT, ALL SERVICE SEPTIC
L.L.C. SHOULD BE NOTIFIED. ALL OWS CONSTRUCTION MUST
RE ACCORDING TO COUNTY REGULATIONS, THE INSTALLER
SHOULD HAVE DEMONSTRATED KNOWLEDGE OF THE
REQUIREMENTS AND REGULATIONS OF THE COUNTY IN
WHICH THEY ARE WORKING. THE COUNTY AND ALL SERVICE
SE"'TIC L.L.C.MUST VIEW INSTALLATION
ALL SERVICE septic, LLC
0357 CRYSTAL LAME
Project NO. 107
PO BOX GLENWOOD
GLEN SPRINGS,
PITKIN COUNTY, COLORADO
REPAIR ONSITE WASTEWATER SYSTEM DESIGN
5-10-05
8-5033
970-618-5033
�
t
i
t
1
1
�
�
1�
r
rj
1
u
SCALE
1"=20'
NORTH
�'10 ` fl
Effluent Pumping System - Law Head Pump - 500 gallon 0
Orenco Systems®
1�qxwaw
814 WWAY AVENUE
SU111E"' aRSM
97474-9012
Inspection Access
Riser and Lid (al
or near ground
surface), optional
Tank Adapter —
(cost or boded)
Inlet Tee
PUMP SPECIFICATIONS - PUMP MUST BE
CAPABLE OF:
GALLONS PER MINUTE = 28
DYNAMIC HEAD = 38.5
2" PVC PUMP"
LINE $Q o
AIR RELEASE AT HIGH
POINT IN PUMP LINE
CHAMBER W ,
SHOUEs O'FILE i W
LD�
FOLLOW PIT 0,
TOPOGRAPHY
533 SF OF CHAMBER TRENCHES
TRENCHES = 3
9 OUTLET CONCRETE
DISTRIBUTION BOX, THE BOX r
SHOULD BE MARKED/LOCATED
FOR FUTURE USE, OR
BROUGHT TO GRADE
�► CHAMBERS PER TRENCH = 18
�'► 'QUICK -4' CHAMBERS = 54
f
29' SETBACK
ti
"fir►
�iguid
TANK SPECIFICATIONS
CAPACITY REQUIRED = q X 1.75 X (30 HOURS/24 HOURS) =1312
GALLONS
REQUIRED TANK = 1250 EXISTING WITH EFFLUENT FILTER,
FOLLOW BY NEW 500 GALLON PUMP, CHAMBER
CROSS SECTION OF TYPICAL CHAMBER -TRENCHES
-+ 4" PVC
OBERVATION
PIPE
4,0' MAX
LIMIT OF EXCAVATION
GRAVELLESS
CHAMBER
6' MINS--+
SCARIFY
SURFACE
INFILTRATOR(R) GUICK4(TM) CUT SHEET
48"
EFFECTIVE LENGTH)
TRENCHES
MUST BE
LEVEL
1,5' MIN
Slope Ground
Away from Riser
Conduit to
Control Panel
-.-
-PVC Splice Box
with Cord Grips
-Fiberglass Gasketed lid with
Stainless Steel Bolts
-PVC Riser with Grommet(s)
(bond to tank adapter with
recommended adhesive)
-Discharge Assembly
-Flexible Hose
Effluent Discharge
P—Tank Adapter (cast or bolted)
Level Control
noot Assembly
Check Valve (optional)
Pump
Block
InITI ONE,
(54.1) 459--1449
FAMM E:
(541) 459-2884
DESIGN
THREE - BEDROOM RESIDENCE, <6000 SF = 600 GALLONS PER DAY
TOTAL LOADING = q = 600 GALLONS PER DAY
PERCOLATION RATE = 25 MINUTES PER INCH
CALCULATED AREA = (1.75 X q X sgrt 15) / 5 = 1050 SF
REDUCTION OF 50% 525 SF
TRENCH SPECIFICATIONS
WIDTH OF TRENCHES = 3 FEET =1 CHAMBER
LENGTH OF TRENCHES = 72 FEET = 18 CHAMBERS
TOTAL NUMBER OF'QUICKA' CHAMBERS=44
TOTAL INFILTRATIVE AREA = 533 SF
Tf IREE TOTAL TRENCHES
NOTES:
TRE=NCHES MUST BE ANGLED TO FIT TOPOGRAPHY
AND TO MINIMIZE REMOVAL OF TREES.
THE SLOPE AT THE PROPOSED DRAIN FIELD IS
APPROXIMATELY 10% TO THE WEST. VEGETATION
CONSISTS OF A FULL COVER OF NATIVE GRASSES WITH
SURROUNDING TREES.
LIMITATIONS - THESE PLANS MUST BE USED IN CONJUNCTION
WITH LETTER AND SOILS DATA FORM PROVIDED. THE DESIGN
IS BASED UPON INFORMATIONSUBMITTED. IF SOIL
CONDITIONS ENCOUNTERED ARE DIFFERENT FROM
CONDITIONS DESCRIBED IN REPORT, ALL SERVICE SEPTIC
L.L.C. SHOULD BE NOTIFIED. ALL OWS CONSTRUCTION MUST
RE ACCORDING TO COUNTY REGULATIONS, THE INSTALLER
SHOULD HAVE DEMONSTRATED KNOWLEDGE OF THE
REQUIREMENTS AND REGULATIONS OF THE COUNTY IN
WHICH THEY ARE WORKING. THE COUNTY AND ALL SERVICE
SE"'TIC L.L.C.MUST VIEW INSTALLATION
ALL SERVICE septic, LLC
0357 CRYSTAL LAME
Project NO. 107
PO BOX GLENWOOD
GLEN SPRINGS,
PITKIN COUNTY, COLORADO
REPAIR ONSITE WASTEWATER SYSTEM DESIGN
5-10-05
8-5033
970-618-5033
LEAKS RESIDENCE
El