HomeMy WebLinkAboutpitkin.eh.264929102021 (2002)Pitkin County Environmental Health Department Permit for an Individual Sewage Disposal System 0405 Castle Creek Road, Suite 10, Aspen, Colorado 81611 Phone 970-920-5070 / FAX 970-920-5077 Permit # 02055 Parcel ID # 2649-291-02-021 Type of permit New Name of Owner Terry Griggs Street Address 103 Apache Trail Redstone CO 81623 Property legal description ti;} 18 Swiss Village Size of lot .977 acres Total square footage of the house 750 Water source Community/Public Water System # of potential bedrooms in Caretaker unit none Total square footage of the caretaker unit # of potential bedrooms in caretaker unit . Designed for what # rooms (list) 2 bedrooms - Permit information Designed by Sopris Engineering 502 Main Street Suit A3 Carbondale 81623 Perc rate 40 mpi Profile hole depth 8 ft Depth to groundwater or bedrock greater than 8 ft Minimum Septic tank capacity 656 gallons Minimum Absorption area 465 sq ft Comments Septic permit approved per compliance with the engineer design and specifications dated May 15, 2002. Any changes must be approved by this department and the design engineer prior to them being made. Minimum horizontal distances between components of the system and physical features shall conform to the Pitkin County ISDS regulations. The dry gulch on the property should be 25 feet from the field. f 12-50 ,C11_11I-(i!(t, This system will consist of one 4 -999 -gallon two-compartment tank with an effluent filter on the outlet. The distribution box will have 3 outlets and a baffle. It should be filled with water at the time of inspection. The field will have 6 rows of 5 gravelless chamber units. This department does not endorse any brand of products. This permit must be kept on-site during installation. The engineer must do a final inspection of the installation and submit an as -built letter to this department. This department must also be called for an inspection with a minimum of 48 hours advanced notice. Permit approved by: e� Date: Plans and specifications of the proposed individual sewage disposal system have been reviewed and are considered satisfactory. Permission is hereby granted to the owner or the agent to perform the work indicated in accordance with the Pitkin County ISDS Regulation in effect at the time of issue. This permit becomes invalid 6 months from the date that the permit was issued unless system construction has commenced or an extension has been approved in writing by the Department. As -built drawings must be,included with this permit before the final approval will be issued. Installer: �i!irVT % fAY1 S Final inspection approval: Date: PITKIN CC NTY ENVIRONMENTAL HEALTH DE 'RTMENT APPLICATk . FOR INDIVIDUAL SEWAGE DISPO.,,,L SYSTEM 0405 Castle Creek Road, Suite 10, Aspen Colorado 81611 Phone 970-920-5070/Fax 970-920-5077 Name of OWNER it 12-p— y ((7 Owner's Mailing Address P. n . �1 g5 2- Ca�rbt) :j1 �27 Business Phone: Home Phone: To GjLLQ � �d Primary Contact Person (all communication regarding this permit will go through this person) Name C (--7- S CompanyC Contact Mailing Address �-� is Business Phone: Cell Phone: `i 4 D Q I Fax: — rarcei iu * tavaiiame rrom assessor's office at 920-5160 or at www.aspen.com/assessor/) Street address of property i()3 A a(b _9 oz_d�-� Legal Description: Lot ,Block Filing Subdivision Size of lot: 917 acres. Type of proposed structure: tbaTA-- Size of bldg. envelope: Total square feet of house 7 # of bedrooms in house 1 # of offices, lofts & similar sized rooms in house Caretaker Unit: Attached ( i Detached # of bedrooms in caretaker unit Total area(sq. ft.) of caretaker unit # of offices, lofts and similar size ms of caretaker Permit is for: New Home ;x) Repair due to failure ( ) Remodel/Addition ( ) Emergency use ( ) Water: Private well ( ) Spring ( ) Stream ( ) Community/Public Water System ( ) If community system: Name of system The fee for a ISDS application is $330 for a permit that takes 6 hours or less for the department to approve. If approval takes longer than 6 hours, a rate of $65 per hour will be charged. The maximum fee is $1000. The basic fee of $330 is due at the time of application. The remainder, if any, will be due in two stages: first, at the time of issuance of the ISDS permit; second, before final approval of the ISDS permit. Application for an individual sewage disposal system is hereby submitted. I hereby certify that the above information is true and accurate and that I have provided true and accurate information on locations of all existing and proposed wells, contour intervals, buildings, property lines, ditches, slopes, waterlines, springs, suction or irrigation lines, drinking water cisterns, drain tiles, irrigation ditches, lakes, water courses, streams, floodplains, dry gulches, and existing septic systems. I hereby certify that any such features not shown on attached site map are not present. Issuance of the permit does not imply the approval of any other permit required for construction pursuant to Pitkin County codes. No construction may be undertaken until all approvals and permits have been obtained. The Aspen/Pitkin Environmental Health Department, Pitkin County and employees of these agencies will be held harmless should the individual sewage disposal system fail or malfunction. The permit to construct is issued on information submitted by the applicant or his/her representatives. The owner assumes full responsibility in case of failure of the system. Signature of applicant Received by G:\eh\isds\isdsapp\isd Receipt # Date -7 Date 1� �' i October 18, 2002 Carla Block Pitkin County Environmental Department 130 S. Galena Aspen, CO 81612 RE: Griggs Residence — As -Built ISDS System, Tract 18, Swiss Village Subdivision, Pitkin County Colorado SE Job No. 21063.01 Dear Carla: Pursuant to your request, this letter provides documentation that the new ISDS system recently installed is in general compliance with the permitted design. The Griggs system has been completed. The system constructed on site was designed and built to serve the needs of the '2 -bedroom home. Sopris Engineering has performed visits to inspect and document the as built conditions of the constructed system. We have coordinated our efforts with the owner and contractor that built the system. The as built conditions and installation of the new ISDS components is in compliance with the permitted design specifications for the system with slight adjustments pertaining to the location and finish grade of the absorption field, requested modifications to the distribution box and an increase in septic tank size. The System was installed in accordance with Pitkin County Regulations; the design presented in the Sopris Engineering Report and the design drawings, dated May 15, 2001. A 1250 gallon dual compartment septic tank was installed with 4" tee baffles and an effluent filter. The absorption field was constructed with 6 parallel chamber rows in a bed configuration as generally delineated on the site plan. The surface grades have been lowered approximately 1-2 feet. Inspection ports were installed on each corner end chamber and on alternate ends of the 2 middle rows. The bed is 32' by 18' approximately 36" deep. The trenches were installed in suitable soil consistent across the bed. A distribution box was installed with a 4" riser to the surface and 3 individual distribution lines connected to 3 pairs of bed chamber rows. The D -box was retrofitted with a concrete baffle to deflect incoming effluent. The construction was completed utilizing specified materials installed according to design. The minimum setback distances have been maintained. Attached is an as -built drawing of the system. The absorption field maintains an offset of 25 feet from a man made channel to the west. This channel serves as an overflow to a water diversion system that fills a storage tank on the adjacent up gradient development. The channel is only has limited intermittent flows. The channel is not a native stream nor does it serve as a ditch. A limited amount of runoff or snowmelt will flow in the channel from a limited tributary area. Based on the soil conditions, absence of ground water and the small daily flow distributed over the absorption bed area we do not expect any lateral movement of treated effluent from the field to the channel. Based on these conditions we consider this channel to be an equivalent dry gulch. If you have any question or need any additional information, please call. Sincerely, SOPRIS ENGINEERING, LLC Paul E. Rutledge Design Engineer RECr Cc: Terry Griggs OCT 2 3 2002 PIThIN COUNTY ENVIRONMENVI. 502 Main Street • Suite A3 • Carbondale, CO 81623 • (970) 704-0311 • Fax (970) 704-0313 SepRis RIN LLC ENGINEEG 0 civil consultants Pitkin County En i QUIllelltdlHealth March 28, 2003 Mr. Terry Griggs P.O. Box 452 Carbondale, CO 81623 Dear Mr. Griggs: On October 16, 2002, Carla Block spoke to you regarding the lack of a baffle on the distribution box for your individual sewage disposal system. She requested that the distribution box be replaced and that photographs of the corrected system be sent to Environmental Health. As of this date, we have not received these photographs. .We would like to complete the processing of your ISDS permit as soon as possible. Please send the photographs to our office by April 11, 2003. - Thank you for your cooperation. Sincerely, Carole Twitchell Pitkin County Environmental Health 0405 Castle Creek Road, Suite 10 Aspen, Colorado 81611 (970) 920-5070 fax 920-5077 www.pitkingov.com �r � „�. �,. � r' '' -i"i �i �' � / � �� }-7 �. r r � l__ l�. � �• � � � �, r ,� � a� '7 Mr. Terry Griggs Griggs Residence 111 N. Harper Avenue Los Angeles, CA 90048 RE: Griggs Residence — Proposed ISDS System, Tract 18, Swiss Village Subdivision, Pitkin County Colorado SE Job No. 21063.01 Dear Mr. Griggs: Pursuant to your request, attached herewith is a letter/report presenting our findings in regard to the feasibility and design for an Individual Sewage Disposal System (ISDS) at the above referenced Site. This design is based on our evaluation of the site conditions with information provided by others for use in supporting your application to Pitkin County. Our recommendations are in accordance with Pitkin County and the State of Colorado ISDS Regulations. Pitkin County must permit any proposed improvement to the site. We have reviewed the information forwarded to us, conducted a site visit, formulated an ISDS design and created a site plan with construction details as part of our scope of work. Conclusions: Based on our findings we believe that the design and installation of an approved ISDS system is feasible in accordance with the Regulations of Pitkin County and the State of Colorado. We recommend that amplaw be installed that will discharge effluent to system. The soil absorption system can be installed in natural soils and will be located within the septic envelope down -gradient of the proposed house, as delineated on the attached plan. The system will meet all required setbacks and be installed within the general boundaries indicated on the plan. Our Design is outlined below and delineated on the attached site plan. Site Location: The subject site is located on Apache Trail, off State Highway 133, on Tract 18 in The Swiss Village Subdivision approximately 3 miles North of Redstone in Eagle County, Colorado. The site is situated in Section 29, T 9 S, R 88 W of the 6th P.M. The Site comprises approximately 0.98 acres. The site is bounded on the north by Tract 19 (single family home), Crystal River Estates, on the west by Cherokee Lane, on the east by Apache Trail and on the south by Tract 17 (single family home). 502 Main Street • Suite A3 • Carbondale, CO 81623 • (970) 704-0311• Fax (970) 704-0313 S OPRIS ENGINEERING 9 LLC civil consultants X ExistinLy Site Conditions: M Mr. Terry Griggs SE Job No. 21063.01 May 15, 2001 Page 2 The site is located on an undeveloped alpine bench. The site has a gentle slope (5-10%) toward the east. The existing ground surface in the proposed septic area is an area with an approximate slope of 2%. The site is covered with native grasses, aspen, willows, cottonwoods and scrub oak. Two distinct flat building envelopes exist on the site. Domestic water is supplied by a ng eentral watetsyst=4 There are no wells within the general vicinity of the site. The nearest existing absorption fields on adjacent lots are located in excess of 100 feet away from the location of the proposed absorption field. Proposed Site Conditions: It is our understanding that you intend to construct a 750 S.F., 1 bedroom guesthouse to be used as a residence until a proposed primary home can be built in the future with a separate ISDS. The maximum number of rooms to be utilized as a bedroom is 1. According to Pitkin County ISDS Regulations the minimum size of a new ISDS shall be based on 2 -bedrooms for a structure 700 S.F. or larger. Therefore the system is designed to handle the flow from an equivale The proposed improvements will include a new ISDS system with appropriate site grading. The new structure is to be generally located in the location shown on the plan. Subsurface Conditions: A subsurface investigation and percolation test was conducted on May 4, 2001 by Hepworth-Pawlak Geotechnical, Inc (HP). The results are attached in the HP report dated May 9, 2001, Job Number 101 334. The subsoil encountered at the site consists of 1/2 foot of topsoil overlying clayey sandy gravel with cobbles and scattered small boulders to the maximum depth explored in the profile pit of 8 feet. The top 3 feet appeared to be man -place fill above a root zone between 3 & 4 feet. Groundwater was not encountered in the test profile pit. Percolation testing utilized three test holes, which yielded similar absorption rates. The fastest measured rate was 30 minutes per inch and the slowest measured rate was 60 minutes per inch. The WrIvi WRIT d is suitable for a conventional absorption system. Design Criteria: The proposed residence is,a 1 -bedroom guesthouse. The design flow is calculated as follows: The new ISDS shall be based on a minimum of 2 -bedrooms for a structure 700 S.F. or larger. Residence unit - 2 bedrooms @ 2 person /bedroom = 4 person From the Pitkin County I. S. D. S. Regulation; Max. Design flow (Qd) = # of people x 1.75(avg. flow) gal/person/day. Gallons per day for the subject house = 75 gal/person/day Qd = 4*75*1.5 =525 a 1/daX C1 Septic Tank Design: Residence X Mr. Terry Griggs SE Job No. 21063.01 May 15, 2001 Page 3 Q = 4*75*1.5 =525 Volume (V) of tank = Design Flow * 1.25 (30 hour retention time) V = 525 gal/day * 1.25 =4"'51 Use one double compartment, concrete Wk97gallon septic tank,, A 750 -gallon tank may be used if available. A polyethylene tank is not recommended. Percolation Test Results: The results of percolation tests indicated the average percolation rate of 40 minutes per inch is within acceptable ranges for conventional absorption systems as required by Pitkin County regulations. The field is sized by using the standard absorption area equation based on the design flow and the percolation rate. A soil absorption be stem, utilizing gravelless leaching chambers is recommended. Pitkin County allows a ion i the size of a bed system utilizing gravelless leaching chambers. Soil Absorption System Design: Based upon the percolation test rates, the standard absorption area equation is: A (SF) = Q *Ut : where A = Area; Q = flow (gal/day) 5 t = time in minutes This design calculation results in a recommended minimum absorption area: A= 525 *(40) ' 664 sq. ft. 5 Apply a 30% reduction for utilizing gravelless leaching chambers. A = 664 sq. ft. (0.70) = 465 sq. ft. Assume 15.5 square feet per chamber: IW. AqsOW 30 chambers 15.5 sq.ft/chamber Use a 562 sf bed with 30 gravelless chambers: We recommend using a bed system composed off; ovA31.25 feet long and 18 feet wide, a ining:A chamber units in each row. Equal distribution is recommended. We recommend that the every two rows be connected with a header pipe to 1 of 3 individual distribution lines coming from a distribution box. The field will be constructed level. The bed shall be constructed not to exceed a maximum depth of 3 feet. An inspection port should be installed on the top mid -point cutout at each corner chamber in the bed. This will allow for checking the performance of the system over time. Mr. Terry Griggs SE Job No. 21063.01 May 15, 2001 Page 4 General Notes:, 1) All materials and installation practices shall conform to the Pitkin County Individual Sewage Disposal Regulation. 2) All sewer lines and distribution lines in the system shall be 4" Schedule 40 or SDR -35 PVC unless specified otherwise on the plans. 3) Add a two-way clean out on the service line from the proposed house. 4) The system shall be plumbed to distribution effluent into the trenches with equal distribution. 5) The contractor shall ensure that the concrete septic tank and sewer lines are watertight. 6) The bed area must be protected to prevent damage from vehicular or livestock traffic and must be crowned to divert drainage runoff away from the trenches to minimize surface infiltration. 7) The leaching chambers shall be installed level in the bed. A splash plate shall be installed on the bed bottom surface below the inlet in each row to prevent scouring from the effluent. The top of the backfill over the chambers shall be covered with filter fabric or other suitable pervious material to prevent the migration of fines from the overlying topsoil layer. 8) The bed must have a minimum cover of 12 inches. A final cover of topsoil, suitable for vegetation, a minimum 4" deep, shall be placed from the top of the pervious cover layer to the finished surface grade. 9) The absorption trenches must be sodded or covered with vegetative ground cover. Our design and recommendations are based upon data supplied to us by others. If subsurface or site conditions are found to be different from those presented in this report, we should be notified to evaluate the effect it may have on the proposed ISDS. If the County Environmental Health Department requests changes or modifications to this design, we should be contacted to evaluate the effect on the ISDS. If you have any question or need any additional information, please call. Sincerely, SOPRIS ENGINEERING, LLC s May 9, 2001 Heewworth-Pawlak Geotechnical, Inc. 5020 County Road 154 Glenwood Springs, Colorado 81601 Phone: 970-945-7988 Fax: 970-945-8454 hpgeo@hpgeotech.com ,Worry Grig@s 111 North Harper Avenue Los Angeles, California 90048 Job No. 101 334 Subject: Percolation Test Results, Tract 18, Swiss Village, Pitkin County, Colorado. Dear Mr. Griggs: As requested by Paul Rutledge with Sopris Engineering, we conducted percolation testing at the subject site. The work was done in accordance with our agreement for professional services to you, dated April 30, 2001. A Profile Pit and three percolation test holes were excavated with a backhoe on May 3, 2001 at the locations shown on Fig. 1. The subsoils exposed in the Profile Pit consisted of aboutMau QJQ bout ra,n n bQuU inwc The +@0194ftlewppoKed;or No free water was observed in the pits and the soils were slightly moist to moist. A small drainage is located about 30 feet south of the percolation test area. Percolation test holes were hand dug in the bottom of shallow backhoe pits and soaked with water on May 3, 2001. Percolation testing was conducted on May 4, 2001 by a representative of Hepworth - Pawlak Geotechnical, Inc. The percolation test results are summarized on Table I. The percolation Based on the subsurface profile and percolation test results, the tested area should be suitable for an infiltration septic disposal system. If you have any questions or need further assistance, please call our office. Sincerely, HEPWORTH - PA Steven L. Pawlak, P SLP/rso/djg 15222 r cc: Sopris Engineering - Attn: Paul Rutledge attachments , INC. APPROXIMATE SCALE 1" = 20' ILI \ 1 PROPOSED \1 RESIDENCE \� i\ TRACT 18 `J'�► SWISS VILLAGE Z \ un, \ �7 \\ SEPTIC DISPOSAL � SYSTEM ENVELOPE \ PROLE \ PIT l : ■ OP 1 1 � I I / I P 2 � / I A I \ / I Z \ PROPERTY — BOUNDARIES APACHE TRAIL 30 20 101 334 1 GEO ECH N I CALW INC- I LOCATION OF PERCOLATION TEST HOLES Fig. 1 10 APACHE TRAIL 30 20 101 334 1 GEO ECH N I CALW INC- I LOCATION OF PERCOLATION TEST HOLES Fig. 1 ,EPWORTH-PAWLAK GEOTECHNI,-AL, INC. TABLE I PERCOLATION TEST RESULTS JOB NO. 101 334 HOLE NO. HOLE DEPTH (INCHES) LENGTH OF INTERVAL (MIN) WATER DEPTH AT START OF INTERVAL (INCHES) WATER DEPTH AT END OF INTERVAL (INCHES) DROP IN WATER LEVEL (INCHES) AVERAGE PERCOLATION RATE (MIN./INCH) P-1 36 15 9 1/2 9 1/4 1/4 60 9 1/4 9 1/4 9 83/4 1/4 83/4 8 1/2 1/4 8 1/2 8 1/4 _ 1/4 8114 8 1/4 P-2 40 15 11 101/2 1/2 30 10 1/2 93/4 3/4 93/4 91/4 1/2 9 1/4 83/4 1/2 83/4 8 1/4 1/2 81/4 73/4 1/2 P-3 44 15 143/4 13 112 1 1/4 30 13 1/2 121/2 1 12 1/2 11 3/4 3/4 11 3/4 11 1/4 1/2 11 1/4 103/4 1/2 Note: Percolation holes were hand dug in bottom of backhoe pits and soaked on May 3, 2001. The percolation tests were performed on May 4, 2001. The percolation rate for each test is the average of the last 3 readings. 1041 HAZARD REVIEW SITE PLAN Pursuant to Section 5-70-040 of the Land Use Code, a 1041 Hazard Review Site Plan shall be prepared as follows: A. Neat, legible ink drawing on a twenty-four (24) inch by thirty-six (36) inch sheet; B. Title identifying type of review: "Smith 1041 Hazard Review Site Plan" C. Vicinity map at a scale of no smaller than 1 " = 2000' and a size of no less than 5" by 5", showing commonly known landmarks and the relationship of the parcel to proximate roads; D. Boundaries of the parcel(s) with a survey tie into a governmental monument or other permanent marker. E. North directional arrow; F. Date; G. Scale: the building envelope and access shall be depicted at a scale of no smaller than 1" _ 50'; H. Topographic information depicting two (2) foot contour intervals within the proposed building envelope and along the proposed access, and extending at least ten (10) feet beyond the envelope and access. Additional topographic information may be required on a site specific basis upon further review. I. Slope analysis: Slopes between each two (2) foot contour that are from 15-30% and those exceeding 30% shall be designated by separate distinct graphic patterns. J. Legal Description of parcel; K. Site map shall also include the location and dimensions of building envelope setbacks from property lines, important physical features, existing water courses, and any other important geographic or hazard related issues. L. Disclaimer stating "1041 environmental hazard areas exist that might affect the property, any improvements, and the use and occupancy thereof'; M. Owner's signature block. N. Community Development Director signature block for minor review or Hearing Officer signature block for Hearing Officer review: "This 1041 hazard review site plan has been reviewed and approved by Director/Hearing Officer this day of , 1999, subject to Administrative Decision/Hearing Officer Decision No. recorded as Reception No. " O. Clerk and Recorder Acceptance for Recording: "This 1041 hazard review site plan has been accepted for filing in the office of the Clerk & Recorder of Pitkin County, Colorado, on this day of , 1999, in Plat Book at Page _ as Reception No. 11 A mylar copy shall be submitted by the applicant for recording following 1041 hazard review approval and prior to issuance of any building permits for the property. At that time, the site plan information shall also be submitted in a digital format acceptable to the Community Development Department. Base information shall be obtained from the Community Development Department. The owner must sign the mylar before recording. A representative of the owner must have a power of attorney in order to sign the mylar for the owner. The applicant shall submit the recording fee with the mylar: $10 per page. Either submit a check made out to the "Pitkin County Clerk" or cash. W Resolution No. _-2002 Page 2 BE IT FURTHER RESOLVED by the BOCC that it does hereby remediate the taking by granting approval, subject to the following conditions, which shall run with the land and be binding on all successors in interest: 1. The Applicant shall record a 24 X 36 inch mylar 1041 Hazard Review Site Plan in accordance with Section 5-70-040 of the Land Use Code. The eastern 100 feet of the property shall be depicted an access/septic envelope that will be approved by Community Development prior to recordation. The site plan shall also be submitted in digital format for integration in to the County Geographic Information System (GIS) prior to submission of a building permit or septic permit. 2. The Applicants shall obtain an access permit from the Pitkin County Engineer prior to building permit submission. Any structure over 30" in height within the required setbacks shall receive Board of Adjustment approval prior to building permit submission. 4. The Applicants shall comply with the following landscaping and wildfire defensible space mitigation standards: a. Brush, debris, and non -ornamental vegetation shall be removed within a minimum 10 foot perimeter around the structure. b. Vegetation shall be reduced to break up the vertical and horizontal continuity of the fuels a minimum 30 foot perimeter around a structure built on flat ground. c. For a distance of 35 feet around all structures, vegetation shall be maintained at 6 inches or less in height. Woody plant materials shall not be planted and flammable materials (e.g. firewood) shall not be stored in this perimeter. d. For a distance of 100 feet downslope of any structure, remove standing dead vegetation. Enhance existing clumps of Gambel oak, serviceberry and other shrubs and trees by reducing the overall diameter of a clump to 2 '/2 times its height and the spacing of clumps to 3 times the height. The area between clumps should support vegetation that remains less than 2 feet in height (e.g. grass, flowers, or snowberry) Mowing between clumps will encourage grass over woody vegetation. e. All branches from trees and brush within the 30 foot perimeter shall be pruned to a height of ten feet (10') above the ground or half the total height of the plant (whichever is least) and removal of ladder fuels from around trees and brush. f. Tree crown separation within the 30 foot perimeter shall have a minimum of ten 10 feet between the edges of the crowns. This does not apply to mature stands of Aspen trees where the above recommendation for removal of ladder fuels have been complied with. In areas of Aspen regeneration, the spacing guidelines shall be followed. g. All branches that extend over the roof eaves shall be trimmed and all branches within 15 feet of the chimneys shall be removed. h. All deadfall within 100 foot perimeter shall be removed. i. Cut stumps shall be treated with Garlon® or its equivalent immediately after cutting. j. The Applicant shall be responsible for the continued maintenance of the defensible space requirements. The Applicants shall comply with the following additional wildfire mitigation standards: a. Roofs shall have a non-combustible roof covering on a Class A, non-combustible roof system. Wood shake/shingle roof coverings are prohibited in all wildfire hazard areas. Roofs with Resolution No. -2002 Page 3 less than a 3:12 pitch are not permitted in 1041 Wildfire Areas unless they comply with the following: i. All roof coverings shall be noncombustible materials as defined in the Uniform Building Code (UBC) 1997 Section 1504 and installed on a Class A roof assembly. ii. All roof coverings shall have a surface that shall facilitate the natural process of clearing the roof. iii. All roof designs shall facilitate the natural process of clearing roof debris. Protrusions above the roofline, such as parapets, shall be prohibited. iv. Roofs shall be installed as required by UBC 1997 Chapter 15 and shall have a minimum slope of 1:48. V. All roof designs, coverings, or equivalent assemblies shall be specifically approved by the Fire Marshal prior to submittal of a building permit application. b. Vents shall be screened with corrosive resistant wire mesh with mesh'/4 inch maximum. c. For Projections below the roof line (which include but are not limited to exterior balconies, decks, porches, cantilevered floor projections, and bay windows) the open space between grade and the underside of projections below roof line shall be enclosed by solid vertical walls. These walls shall be constructed with materials approved for 1 hour fire -resistive construction on the exterior side of the wall and shall extend from the top of grade to the underside of the floor decking or walls of the projection. An alternative construction method for such projections would require use of non-combustible building materials, or heavy timber or log wall construction, or the underside of the projection portion shall be covered with materials approved for one-hour fire -resistive construction if there are no inside angles of less than seventy-five degrees (75°). Areas below such projections shall be void of vegetative or other combustible materials. These areas below projections shall be protected from accumulation of vegetative materials by placement of a vegetative barrier covered with rocks or gravel or by coverage with concrete stone. There shall be no storage of combustible materials under projections. The walls underneath projections shall be constructed with materials approved for 1 -hour fire -resistive construction on the exterior side of the wall. Window openings in walls below projections shall be tempered glass. Doors shall be noncombustible or 1 3/4" solid wood. d. Glazed openings shall be provided with closable, solid, exterior non-flammable shutters or shall be tempered glass. e. Siding and exterior wall construction shall have a minimum one-hour fire -resistive rating, ground level to roof -line. Exterior doors shall be noncombustible or 1 3/4 inch solid wood. f. Foundations, skirting and crawl space openings shall be fully enclosed and constructed with materials approved for one-hour fire -resistive construction on the exterior side of the walls and shall extend from the top of grade to the underside of the floor decking or walls. g. Roofs and gutters shall be kept clear of debris. It. Yards shall be kept clear of all litter, slash, and flammable debris. i. All flammable materials shall be stored on a parallel contour a minimum of 15 feet away from any structure. j. Firewood/wood piles shall be stacked on a parallel contour a minimum of 15 feet away from the structure. k. Swimming pools or ponds shall be accessible to Fire Department vehicles. 1. Fences shall be kept clear of brush and debris. in. Wood fences shall not connect to the structure. n. Fuel tanks shall be installed underground with an approved container. o. Propane tanks shall be installed according to NFPA 48 standards and on a contour away from the structure with standard defensible space vegetation mitigation around any above -ground tank. Any wood enclosure around the tank shall be constructed with materials approved for 2 hour fire - resistive construction on the exterior side of the walls. Resolution No. _-2002 Page 4 p. Each structure shall have a minimum of one 10 pound approved ABC fire extinguisher placed in a visible and accessible location. q. Addresses shall be clearly marked with 2 inch non-combustible letters and shall be visible and installed on a non-combustible post. 7. Prior to submission of building permit for any residential structure, the Applicant shall build a dike to contain any potential mud/debris-flow through the property in accordance with the attached geologic report written August 15, 2001, by Ralph Mock of H.P. Geotech. The County Engineer shall approve specifications for the dike prior to building permit submission. The Applicant shall refer to the County Engineer for methods to mitigate mud/debris flows across Cherokee Lane and shall implement those recommendations prior to Certificate of Occupancy for the residence. 8. Pursuant to Ordinance No. 022-2000, the Applicant is subject to the Fair Share Requirements and shall pay a road impact fee as calculated at the same time as building permit issuance. Floor area shall be limited to 2,000 square feet. Floor area shall be calculated based on the definition in effect at the time of building permit submittal. 10. The Applicants shall adhere to all material representations made in the application or in public meetings or hearings and shall consider those representations to be conditions of approval, unless amended by other conditions. 11. No development, including grading, excavation, fill placement, berming, landscaping, entry or ranch gates, and vegetation removal or disturbance shall occur outside of the approved building [and/or] development envelopes unless otherwise specified in this document, such as necessary wildfire mitigation. Construction, staging, parking, utility and driveway extension and maintenance shall occur within approved building, or access driveway. 12. Prior to commencement of any earthmoving or construction activity, the Applicants shall stake the corners of the building envelope and install construction fencing around the perimeter of the building envelope. The fencing shall remain in place until issuance of certificate of occupancy. 13. This approval and takings remediation shall be valid for one year from this date and thereafter any development on the property must comply with these conditions and any subsequent changes to the County Land Use Regulations. Resolution No. _-2002 Page 5 APPROVED AND ADOPTED on the 13th day of March, 2002. ATTEST: Lyndee R. Dean, Clerk to the BOCC APPROVED AS TO CONTENT: Cindy Houben Community Development Director P69-01 PID #264929102021 BOARD OF COUNTY COMMISSIONERS, PITKIN COUNTY, COLORADO UZZ Patty Kay -Clapper, Chair APPROVED AS TO FORM: John Ely County Attorney ( IN FEET ) 1 inch = 20 ft TWO WAY CLEAN OUT PROPOSED GRADE PROPOSED BUILDING EXISTING GRADE EFFLUENT FILTER OUTLET TEE \---EFFLUENT DRAIN LINE AT MINIMUM 2% SLOPE SEPTIC TANK EFFLUENT DISCHARGE LINE AT MINIMUM 1% SLOPE —DISTRIBUTION LINES AT MINIMUM 1% SLOPE CROSS SECTION SYSTEM DETA N.T.S. 21063.01 ` 70 JA mEgsoI�P2 OD M poi fob T -11M oqq� mg,d CAA C.) $ 2X U) CD W m rn (A 2 -4226 0W ;D in w CD 4rrjCDr^� a� Kvz Cb S t 1 " A .h- N O m d s m � C Cid m N O TrCot-- rrvsteV River Estates N — J / 82051'00•E / INSTALLED 30 LEACHING CHAMBERS IN 6 RWS Tr�et 1� 5. LOCATION OF ROWS M Y BE ADJUSTED AS LON �S / / ' LOCATION OF THE D MUA TOTAL OF 465 SQ. FT. ST BEEWITHIN THE Com. IS PROVIDED. 30 / / / / / \ / / BED SEPTIC ENVELOPE AND MEET ALL COUNTY SETBACK REQUIREMENTS. THE SYSTEM SHALL BE -}930 PLUMBED FOR EQUAL DISTRIBUTION. THE CHAMBERS IN THE BED SHALL BE INSTALLED AT LEVEL GRADE THE i ���� BOTTOM ELEVATION OF THE BED SHALL BE INSTALLED / 4' DIA. SOLID Rv6 / HEADS PIPE AT A MAXIMUM DEPTH OF 36 INCHES TO THE BOTTOM SC EEDULE 40 (TYPL)�� _ SURFACE BELOW PROPOSED GRADE. ISN BOX CI ~ I I I 1 \ / / I / / WI ITRRISER PPO 1 -BED. AY / CSU HOUSE (�Rs ABSORPTION BED SHALL MARKED AND PROTECTED �R0VEHICULAR TRAFFIC 34' i\ __ TWO WAY �I�"p CULVERT // \ \ — — _ E -'L" FROM\ HOUSE �{�{��� / NS0ECT10N PORT / 1 J PROPOSE � / .25' EN / SEPTICJT FI� W/ i �- MIT`S OF iEXCAVAYON / / / / / / \ ) III/� / rnl VFRCT jer 29256 Tri 20 0 / I CROWN FIELD TRENCH TO DIVERT SURFACE WATER SOD OR OTHER SUITABLE 4" SOLID PVC VEGETATIVE COVER DISTRIBUTION PIPE TOPSOIL F- 4" MIN. UNDISTURBED \/ i EARTH 12" FILTER FABRIC MIRAFI\\ \\ SCREENED BACKFILL NATIVE SOIL AND GRAVEL NOT EXCEED 2-1/22"" DIA. STANDARD INFILTRATOR VARIES PER # OF SCARIFY/TILL BOTTOM SURFACE TO CHAMBER ROWS A DEPTH OF 3" AND RAKE LEVEL NOTE: ALL ROWS OF CHAMBERS IN A BED MUST BE LEVEL. MAXIMUM DEPTH OF BED BOTTOM NOT TO EXCEED 36". INLET AND END CAPS ARE TO BE INSTALLED ON THE HEAD AND TERMINAL END CHAMBERS RESPECTIVLEY. INSTALL A 4' VERTICAL INSPECTION RISER FROM THE CENTER CUT OUT ON THE 4 CORNER CHAMBERS IN THE BED. CROSS-SECTION STANDARD CAPACITY LEACHING CHAMBER SYSTEM NOT TO SCALE - LEACHING CHAMBER N.T.S. AL_ SCREENED BACKFILL - NATIVE SOIL AND GRAVEL NOT TO EXCEED 2-1/2" DIA. CENTER CUTOUT 12' (MIN.) 1 I,::. __, : I Lr CHAMBERS UNDISTURBED SOIL SOLID 4" PVC—/ DISTRIBUTION PIPE PLAN VIEW STANDARD CAPACITY LEACHING CHAMBER SYSTEM NOT TO SCALE ;ED SYSTEM GRAPHIC 10 20 ( IN FEET ) 1 inch = 20 ft. TWO WAY CLEAN OUT RADEEPROPOSED GRADE— EXISTING XISTING GRADE EFFLUENT FILTER OUTLET TEE �— PROPOSED BUILDING 80 ISDS SYSTEM NOTES 1. ADD A TWO-WAY CLEAN OUT ON THE SERVICE LINE FROM THE HOUSE. 2. ALL MATERIALS AND INSTALLATION SHALL CONFORM TO PITKIN COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM (ISDS) REGULATIONS. 3. ALL SEWER LINES TO BE SDR -35 OR SCHEDULE 40 P.V.C. PIPE UNLESS NOTED OTHERWISE. 4. THE CONTRACTOR SHALL ENSURE ALL SEWER LINES AND SEPTIC TANKS ARE WATERTIGHT. ANY POTENTIAL PLUMBING LEAKS SHALL BE REPAIRED TO AVOID EXCESSIVE WATER ENTERING THE SEPTIC SYSTEM. 5. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO CONTACT ALL UTILITY COMPANIES FOR FIELD LOCATIONS OF UTILITIES PRIOR TO CONSTRUCTION AND EXCAVATION. 6. THE ABSORPTION BED MUST BE MARKED AND PROTECTED TO _ PREVENT DAMAGE FROM VEHICULAR AND LIVESTOCK TRAFFIC. 7. THE TANK SHALL BE INSTALLED LEVEL ON COMPACTED EARTH. INSTALL WATERTIGHT RISERS AS NECESSARY TO BRING ALL REQUIRED ACCESS N INSTALL THE INLET AND OUTLET TEES TO BE EASILY INSPECTED AND MAINTAINED FROM THE TANK RISERS AND ACCESS LIDS. AN EFFLUENT FILTER SHALL BE INSTALLED IN THE OUTLET TEE OF THE SEPTIC TANK. THE EFFLUENT FILTER SHALL BE CLEANED WHEN THE TANK IS PUMPED OR AS NECCESSARY. INSTALL A SUITABLE EXTENSION ON THE FILTER WITH A HANDLE TO BE WITHIN 6" BELOW THE ACCESS LID. 8. THE ENTIRE ABSORPTION BED SURFACE MUST BE SODDED OR RE -VEGETATED WITH GROUND COVER. 9. THE ABSORPTION TRENCH SURFACES MUST BE CROWNED TO DIVERT SURFACE DRAINAGE AWAY FROM THE BED. 10. THE DIMENSIONS SHOWN ON THE PLAN INDICATE MINIMUM AREA AND SEPARATION DISTANCES FOR THE ABSORPTION FIELD. 11. THE BED SHALL BE LEVEL AND CONNECTED FOR EQUAL DISTRIBUTION. THE MAXIMUM DEPTH OF ANY PORTION OF THE BED SHALL NOT EXCEED 36". 12. THE CONTRACTOR SHALL NOT EXCAVATE TO A DEPTH GREATER THAN -3 FEET-AT-ANY-ONE-LOCATION--WTrH[N- HE- SITE -OFA— PROPOSED ABSORPTION CHAMBER FIELD. THE MINIMUM COVER OVER THE TOP OF THE LEACHING CHAMBERS SHALL BE 12 INCHES NOT TO EXCEED 24 INCHES. 13. THE LEACHING CHAMBERS WILL BE BACKFILLED WITH EXCAVATED MATERIAL VOID OF ROCKS, THE BACKFILL MATERIAL SHALL NOT EXCEED 2 1/2" DIAMETER AND SHALL BE PLACED TO AT LEAST 6 INCHES ABOVE THE TOP OF THE CHAMBERS. THE TOP OF THE PLACED BACKFILL SHALL BE COVERED WITH A LAYER OF FILTER FABRIC. A MINIMUM 4" DEPTH OF TOPSOIL IS TO BE PLACED ABOVE THE BACKFILL TO THE SURFACE. THE TRENCH BOTTOM SHALL BE SCARIFIED IF SMEARING OCCURS. 14. VERTICAL INSPECTION PORTS SHALL BE INSTALLED FROM THE CENTER PRE MARKED HOLE ON THE TOP OF THE CORNER END CHAMBERS. (TYP. ENDS OF OUTER ROWS) A SPLASH PLATE SHALL BE INSTALLED ON THE BED BOTTOM BELOW EACH ROWS INLET TO PREVENT SCOURING. 15. ALL INSTALLATION OF LEACHING CHAMBERS SHALL BE IN CONFORMANCE iRI!TH THE MANUFACTURES INSTALLATION INSTRUCTIONS. GENERAL NOTES: 1. THE ISDS SYSTEM AS SHOWN ON THE PLAN AND THE DETAILS WERE DESIGNED BY SOPRIS ENGINEERING. THE PROPOSED HOUSE, DRIVEWAY AND PROPOSED BOILING ENVELOPE WAS PROVIDED BY THE OWNER. THE EXISTING LOT CONDITION AND SURVEY INFORMATION WAS PROVIDED BY LINES IN SPACE. 2. THE CONTOUR INTERVAL ON THIS MAP IS 2 FEET. A %—EFFLUENT DRAIN LINE AT MINIMUM 2% SLOPE EFFLUENT DISCHARGE LINE SEPTIC TANK AT MINIMUM 1% SLOPE ISTRIBUTION LINES AT MINIMUM 1% SLOPE - 1 10/17/02 AS -BUILT SYSTEM PER N0. DATE - REVISION BY GRIGGS RESIDENCE, TRACT 18 , SWISS VILLAGE SUBDIVISION, PITKiN COUNTY, COLORADO CROSS SECTION SYSTEM DETAIL GMGGS AS -BUILT ISDS SYSTEM N.T_S., a INDIVIDUAL SEWAGE DISPOSAL' SYSTEM - SITE PLAN AND SYSTEM DETAILS - -,, _,. n _ :< .ORRISENGINEERING LLC. IVIL pp 2 a _ av . ..... m A f J d x � "SUITE - .IIT � ..�:. , ..:. ,-:. -., � .. ., :_ .Z_. 1111 A3 }�� .. .s... .f-..- qq ,. ._ .r _ . . ...... ..,. ....:£..- -�+ ._ _ r_ _ .-. _ _CAR OND .. � � , _ st: Alf 'CO 81fi . x �_. sa ,x 970 �. .p Y21iiG r%� s , wti- _ ma .{ : s '�:,"�`