HomeMy WebLinkAboutpitkin.eh.264929102043 (2016)HE per Pitkin County Environmental Health Department Onsite Wastewater Treatment System (OWTS) USE PERMIT Permit for Continued Use of an Existing OWTS 76 Service Center Road, Aspen, CO 81611 Phone: 970-920-5070 Fax: 970-920-5077 www.aspenpitkin.com/EHNR Parcel ID #: 2649-291-02-043 OWTS Use Permit #: I 0006.2016.POWU Date Issued: 03/14/2016 Issued By: Bryan Daugherty Expiration Date: 03/14/2017 Owner(s): I Cynthia L Hines Property Address: 200 Ute Trail Legal Description: Lot 31, Swiss Village Tracts Licensed Inspector: Carla Ostberg Inspection Date(s): 2/23/16 SYSTEM INFORMATION Components Type Capacity/Size Primary Treatment Unit Concrete 2 compartment tank* 1500 gallons Secondary Treatment Unit Absorption Area Gravelless Chamber bed 698 ft' Other System Components ❑In use at the time of the inspection. ®Not in use at the time of the inspection.* *If the OWTS was not in use at the time of the inspection, it is recommended that the system be re-evaluated when it is in use for a more accurate evaluation of the system. System Records: Permit #: 04100 Date of Issuance: 12/16/2004 Date of Final Approval: 05/02/2005 # of Bedrooms or fixtures served by OWTS: 3 bedrooms Operational Status: According to the inspectors observations the system was functioning properly at the time of inspection. The tank was in good condition, tees were in place, and effluent filter was installed. The field area was covered in snow but observation ports were checked and had no standing water. Inspector Recommendations: Clean the effluent filter annually. Department Recommendations: N/A Issuance of this OWTS Use Permit is based solely on the conditions observed and reported by the inspector to the Department on the date of the inspection(s) and on Department records at the time of permitting. The issuance of this permit does not constitute a guarantee, warranty, or representation by the Department that the system will operate properly or will not fail or that the system will not be subject to future enforcement action to correct non-compliant conditions. Estimated capacity of the system has been listed on the permit and we recommend that you monitor and/or meter water use to prevent overuse and possible failure. w TKIN COU N T Pitkin County Environmental Health Department Onsite Wastewater Treatment System (OWTS) USE PERMIT APPLICATION 76 Service Center Rd Aspen, CO 81611 Website: www.aspenpitkin.com/ehnr/ Aunlication for Continued Use of an Existing OWTS Parcel ID# (available from the Pitkin County Assessor's Office 970-920-5160 or at www.pitkinassessor.org): _ n D v Contact/Applichnt Mailing Address: City, State, Zip: Purpose of Use Permit: PROPERTY TRANSACTION ❑ REMODEL/ADDITION Property Address - 0 o Crtor ;z3 Lot: Bock: Filin : Subdivis"70t 31 55 Residences: Other # of Bedrooms: fixtures/uses: Prop1-\1;A1& O-Email Addre :L. res a va,a�c/lehou5e a7 mac, �rr1 Owner's ailing Address: City, S te, Zip: 200 7"r( CGt,��dho�a�e, 0o 1or " SlCO�3 Ho Phone- B"ftnest Phone: �rlo) RG3- 5-5-5 (q'1o) l L ;2-<v 'Contact information must be provided for the owner signing this application Pri ryNCon act Per on/Applicant (if n t owner): �! l 111 Company: Contact/Applichnt Mailing Address: City, State, Zip: Cell Phone: Business Phone: Fax Number: Email Address: Indicate Preferred Method of Permit Receipt: ❑ Email ❑Fax ❑ US Mail is nsed Systems Insp ct r: hone Number: Email Addre s: Fax Number: �5 CM, os-�balib n Aailing Address: Ci State, Zip: o ( r DLEASE READ BEFORE SIGNING: certify that the above information is complete and accurate and that I have provided complete and accurate information in all of the documents ncluded in my application package. 1 acknowledge that this department may revoke any permit I am issued if my application is found to contain any naccurate, false, or misleading information. 11, Ma"aiWYMA� d 1/ /M IW,111].t!i AM, /i �. Please allow 3-5 business days for processing of Use Permits. FOR OFFICE USE ONLY; Received by EH Staff: Fee 8 Receipt*. Date: rV—%OC --)r-,1t- Pe—)L.�A ) PITKIN ENVIRONMENTAL HEALTH DEPARTMENT ISDS DESIGN CALCULATIONS Owner's Name Parcel ID # House Size (sq. ft.) (75 gpd, 100 gpd, or 130 gpd) Number of Bedrooms in Main House Number of Offices, Libraries, Studies, Similar -sized Rooms in Main House Number of Bedrooms in Detached Caretaker unit Number of Offices, Studies, Similar -sized Rooms in Caretaker Unit (If the caretaker unit is ATTACHED, treat as if part of main house.) Average Daily Waste Flow 450 State Review Required? no Perc Rate (T) Design Flow (Q) = # potential bedrooms X 2 people/ bedroom X gpd X 1.75 Q= 787.5 Minimum tank capacity 984.375 gallons Absorption Area (=Q/5 X SQRT perc rate) A = 996.11746 sq. ft. of absorption area required 64 gravelless chamber units without reduction # of Perc Holes Required: 3 1 in every soil type? Spaced uniformly over proposed area? QUICK 4 9_8 A = 498.05873 sq.ft. with 50% reductionTRENCHES 51 gravelless chamber units with reduction STANDARD A = 498.05873 sq.ft. with 50% reductionTRENCHES 32 gravelless chamber units with reduction EQ 36 31 EQ36 units in TRENCHES SETBACK FROM WELL # of feet = 100 SETBACK FROM POND, STREAM OR IRRIGATION DITCH # of feet = 50 SETBACK FROM DRY GULCH # of feet = 25 75 QUICK 4 9.2 697.28222 sq ft 30% reduction BED 76 ober units with reduc. `7 `J' 697.28222 sq ft 30% reduction BED 45 chamber units with reduc. 56 EQ36 units in a BED -2 6 �� - '2�/ - 0-)- - 6q 3 12M3 QMd1-2M=1UbS4OC AVWOO U a i 1, Carla Ostherg t.�Ck'stk' 200/201 Ute septic B & R Septic Service Inc. < brseptic@aol.com> Fri, Nov 29, 2013 at 10:15 AM To: Carla Ostberg <carIa.ostberg@gmaiI.,com>, Chris Patrick <cpatrick@masonmorse.com> Carla, Chris At 200 Ute I used (2112" inch risers and one 6" per each side. The titer was cleaned and the handle replaced with one that was the proper length for the additional risers. The inlet T was cleaned and a top cover was discovered on the T. The lid on the inlet side of the tank was replaced. Note: The tank had filed with water after pumping. I observed water running out of the outlet while working on the titer. I would guess a water softener or toilet is leaking in the home. The work stated above was completed on Wednesday 11-27-2013. Please see attached photos. I also have additional photos and 2 short video of the water lowing out of the outlet if needed. Thank You, Bob Williams B & R Septic SerWces, Inc. 0603 Handy Drive Carbondale, Co 81623-9411 Phone! (070) 963-3814 Aspen: (970) 920-2059 Fax: (970) 963-6070 Email. bF-5ePVC@aO1,CVM 7 attachments MpaAM1.qzcg 113 1111 Carla Ostberg <carla.ostbcrg@gmail.com> ZOO/201 Ute se ptic B & R Septic Service Inc. <brseptic@aol.com> Fri, Nov 29, 2013 at 10:15 AM To: Carla Ostberg <carla.ostberg@gmail.com>, Chris Patrick <cpatrick@masonmorse.com> Carla, Chris At 200 Ute I used (2 )12" inch risers and one 6" per each side. The litter was cleaned and the handle replaced with one that was the proper length for the additional risers. The inlet T was cleaned and a top cover was discovered on the T. The lid on the inlet side of the tank was replaced. Note: The tank had with water after pumping. I obsen/ed water running out of the outlet while working on the 1 ilter. I would guess a water softener or toilet is leaking in the home. The work stated above was completed on Wednesday 11-27-2013. Please see attached photos. I also have additional photos and a short video of the water rowing out of the outlet if needed. Thank You, Bob Williams B & R Septic Services, Inc. 0603 Handy Drive Carbondale, Co 81623-9411 Phone: (910) 963-3614 Aspen: (910) 920-2059 Fax: (970) 963-6070 Email: brseptic@aol. com 7 attachments 12013 pbO40 (4)apg ,QBK pbWb (4).Jpg 62K photo (4).Jpg 56K photo (4).Jpg 9QK (snail- 2DW" Ubaopk photo (4)•1`p9 &7K photo (4).Jpg 114K ttlpe.wal.gmgIe.corvnmL £34ai t�e4lfSi 98i wpFE�e6GiY�it nStlw1A 265ef18e9 photo (4).jpg mm 1=13 photo (4kjp9 504 P-7-35K=—IUI 1 PtOsJ,VMI,9a:9pMearchir&Ary142a4k2YA18M) M February 28, 2016 Cindy Hines avanlanchehouse(ag_mail.com Onsite Wastewater Treatment System (OWTS) Use Permit Inspection 201 Ute Trail Pitkin County, Colorado Ms. Hines, As requested, CBO Inc. performed an Onsite Wastewater Treatment System (OWTS) Use Permit inspection at 201 Ute Trail, Carbondale, Colorado on February 23, 2016. The legal description of the 0.360 -acre property is Lot 31, Swiss Village Tracts. While the address listed on Pitkin County Assessor's Website is 201 Ute Trail, it is posted at the entrance to the property as 200 Ute Trail. The original permit and record drawing was provided by Pitkin County Environmental Health Department (Parcel ID # 2649-291-02-043). The subject OWTS consists of one 1000 -gallon, two- compartment concrete septic tank and a soil treatment area (STA) consisting of a gravelless chamber bed with 15 'Standard' Infiltrator® chambers per row for a total of 45 chambers and approximately 698 square feet of infiltrative area. Pitkin County Individual Sewage Disposal System Permit 04100, finalized on May 2, 2005, documents this system. Pitkin County also issued OWTS Use Permit 0056.2013.powu on December 4, 2013. The septic tank manhole lids were both accessible from grade. The septic tank appeared to be in good condition with both inlet and outlet tees present. The outlet side of the septic tank (risers) was showing signs of deterioration due to gasses. The upper opening of the inlet tee is capped. Sometimes, this is done to prevent odors from migrating back into the house. There are no issues with this cap remaining; however, it prevents visual inspection of flow coming into the septic tank. An effluent filter was installed on the outlet of the septic tank. This filter must be cleaned annually, or as needed. Accumulation of sludge and scum in the tank warrant pumping as part of routine maintenance. The septic tank must be pumped prior to obtaining the OWTS Use Permit. The STA had some snow cover; however, we were able to locate some inspection ports. The ports we observed were dry at the time of the inspection. The distribution box was not accessible from grade and we were not able to inspect this component. There was a trailer stored on the STA at the time of our inspection. We recommended it be removed without driving over the STA (pulled out by hand or with a winch). Weeds had overgrown the surface over the STA. The weeds were tilled out and we recommend plating a native grass seed mix needing minimal irrigation. The STA showed no signs of saturation, and had no indication of failure. This evaluation is not a guarantee of future system performance. This inspection is good for one year. CBO Inc. 33 Four Wheel Drive Road Carbondale, CO 81623 cell) 970-309-5259 office) 970-704-0484 carla.ostberg(agmail.com February 28, 2016 Cindy Hines avanlanchehouse(ag_mail.com Onsite Wastewater Treatment System (OWTS) Use Permit Inspection 201 Ute Trail Pitkin County, Colorado Ms. Hines, As requested, CBO Inc. performed an Onsite Wastewater Treatment System (OWTS) Use Permit inspection at 201 Ute Trail, Carbondale, Colorado on February 23, 2016. The legal description of the 0.360 -acre property is Lot 31, Swiss Village Tracts. While the address listed on Pitkin County Assessor's Website is 201 Ute Trail, it is posted at the entrance to the property as 200 Ute Trail. The original permit and record drawing was provided by Pitkin County Environmental Health Department (Parcel ID # 2649-291-02-043). The subject OWTS consists of one 1000 -gallon, two- compartment concrete septic tank and a soil treatment area (STA) consisting of a gravelless chamber bed with 15 'Standard' Infiltrator® chambers per row for a total of 45 chambers and approximately 698 square feet of infiltrative area. Pitkin County Individual Sewage Disposal System Permit 04100, finalized on May 2, 2005, documents this system. Pitkin County also issued OWTS Use Permit 0056.2013.powu on December 4, 2013. The septic tank manhole lids were both accessible from grade. The septic tank appeared to be in good condition with both inlet and outlet tees present. The outlet side of the septic tank (risers) was showing signs of deterioration due to gasses. The upper opening of the inlet tee is capped. Sometimes, this is done to prevent odors from migrating back into the house. There are no issues with this cap remaining; however, it prevents visual inspection of flow coming into the septic tank. An effluent filter was installed on the outlet of the septic tank. This filter must be cleaned annually, or as needed. Accumulation of sludge and scum in the tank warrant pumping as part of routine maintenance. The septic tank must be pumped prior to obtaining the OWTS Use Permit. The STA had some snow cover; however, we were able to locate some inspection ports. The ports we observed were dry at the time of the inspection. The distribution box was not accessible from grade and we were not able to inspect this component. There was a trailer stored on the STA at the time of our inspection. We recommended it be removed without driving over the STA (pulled out by hand or with a winch). Weeds had overgrown the surface over the STA. The weeds were tilled out and we recommend plating a native grass seed mix needing minimal irrigation. The STA showed no signs of saturation, and had no indication of failure. This evaluation is not a guarantee of future system performance. This inspection is good for one year. Recommendations: • Clean effluent filter annually, or as needed. • There should be no traffic or heavy equipment stored in the area of the STA. • Plant native grass seed over STA. This report and the invoice from pumping must be submitted to the Pitkin County Environmental Health Department. The following links are the required application and application checklist. Application: htto://www.r)itkincounty.com/DocumentCenter/HomeNiew/621 Application Checklist: http://www.pitkincounty.com/DocumentCenter/HomeNiew/620 Disclaimer. This inspection is intended only as an evaluation of the present condition of the OWTS based upon what was observed and the Licensed Inspector's expertise in onsite wastewater technology. The Inspector has not been retained to warrant or guarantee the proper functioning of the system for any period of time in the future. Because of numerous factors which may affect the operation of an OWTS, as well as the inability of the Inspector to supervise or monitor the use or maintenance of this OWTS, this report shall not be construed as a warranty by the Inspector that the system will function properly for any particular prospective buyer, and the Inspector disclaims any warranty, either expressed or implied, arising from the inspection of the OWTS or this report. The evaluation does not ascertain the impact the system is having on groundwater. Please call with questions. Sincerely, Nth Carla Ostberg, MPH, REHS NAWT Certified Inspector Certification # 110441TC Exp. April 2018 Entrance to property (note address different from that listed on Pitkin County Assessor's Website) Clean out between house and septic tank View of septic tank lids looking south Inlet tee (Note cap on top of inlet tee) Effluent filter on outlet tee r - r +3 i STA (looking north) utre730- � 0- y'�,�Air � t«- 1 � STA (looking south) Inspection port h I N Onsite Wastewater Treatment Systems (OWTS) Use Permit Inspection Form ""COU N'i* Pitkin County Environmental Health Department 76 Service Center Rd, Aspen, CO 81611 Phone: 970-920-5070 Fax: 970-920-5374 Website: www.aspenpitkin.com/ehnr Inspection form for continued use of an existing OWTS Owner's Name: Address: Parcel Number: Inspection Date: Inspector's Name: Business Name: Phone Number Email: Cod- 3/ v✓v,55 y0to 2 7"f0 C A 3('90 Pitkin County Systems Inspector License NumberL) � 0 1-1 A copy of this inspection report will be remitted to Pitkin County Environmental Health Department by the Licensed Systems Inspector within 60 days of the inspection regardless of whether the system passes or fails. QUESTIONS FOR PROPERTY OWNER PRIOR TO INSPECTION: Is the home currently occupied? -YES NO If NO, how long has the home been vacant? How many bedrooms are in the home? If secondary treatment is used, who is the maintenance provider?_ RECORDS: Were system records available from Pitkin County? YES NO If YES: Permit number: Date of Final Approval: nrj5 # of bedrooms permitted: Was an as -built drawing available? YE NO Is the as -built drawing accurate? MESS NO If NO: Complete a drawing of the system on last page of this form as accurately as possible. Any question marked FAIL will require correction before an OMITS Use permit is issued. SITE CONDITIONS: Proper grading, no evidence of erosion? FAIL Improper vegetative cover? NO " YI5 Evidence of compaction such as heavy machinery or livestock? NO sr Improper discharges such as straight pipes? PAS FAIL Evidence of high ground water? YES Snow cover present? NO YES Page 1 AV c jlwV J TANK: Tank 1 FAIL Tank 2 N Tank 3 If YES, is the pump/dosing siphon functioning properly? Tank capacity YES gallons PASS gallons Is the high water alarm working, both visible and audible? gallons Tank material SECONDARY TREATMENT: YES is a secondary treatment unit present? YES N90,) UNKNOWN # of compartments 2. Does the owner have a current maintenance contract for the unit? YES NO UNKNOWN Maintenance Provider: Phone: Date of last pumping Noy 0 Lids/risers in good condition ,_E SSS FAIL PASS FAIL PASS FAIL Risers to grade YES NO YES NO YES NO Riser height qI 7 Riser condition/watertightness fJ Inlet sanitary T/baffle PAS FAIL PASS FAIL PASS FAIL Outlet sanitary T/baffle P FAIL PASS FAIL PASS FAIL Effluent filter (if part of design) PASS FAIL N/A PASS FAIL N/A PASS FAIL N/A Condition of tank material FAIL PASS FAIL PASS FAIL Tank was pumped for inspection v YES N YES NO YES NO If YES, list the pumping company If NO, when was the last pumping Scum level (1st compartment) inches inches inches Sludge level (1st compartment) inches inches inches Scum level (2nd compartment) inches inches inches Sludge level (2nd compartment) _ inches inches inches Backflow (if pumped) PASS FAIL PASS FAIL PASS FAIL Midtank baffle PASS FAIL N/A PASS FAIL N/A PASS FAIL N/A Watertightness PASS FAIL PASS FAIL PASS FAIL PUMPS/DOSING SIPHONS: YES FAIL Is a pump or dosing siphon present? N FAIL If YES, is the pump/dosing siphon functioning properly? PASS YES Does the pump/wiring/dosing siphon appear to be in good condition? PASS FAIL Is the high water alarm working, both visible and audible? PASS FAIL SECONDARY TREATMENT: YES is a secondary treatment unit present? YES N90,) UNKNOWN If YES, does the unit appear to be in good working condition? YES ----No Does the owner have a current maintenance contract for the unit? YES NO UNKNOWN Maintenance Provider: Phone: PASS FAIL If there is no maintenance contract, a contract must be in place prior to occupancy of the home. A copy of the contract must be submitted to Pitkin County Environmental Health Department. ABSORBTION AREA: Effluent surfacing? PASS FAIL Evidence of past surfacing? N YES Surface dampness? rflD^. YES Excessive odors? _�.-, YES Field location verified by observation ports or probing: Ports' Probing Liquid in observation port? YES If YES, record depth: _ inches NO Distribution Box or ADV part of original design? �� If YES, is it accessible from grade? YES NO,, .......-. . Is it level and in good condition? PASS FAIL Page 2 UNKNOWN Any problems with the system that were not addressed in the inspection checklist? J) Please list any recommendations for the continued use of the system: d l Were any repairs done as a result of this inspection? NO YES If YES, please describe the repairs. To the best of my knowledge and training, the information collected in this inspection is accurate as of j 20 Licensed Systems Inspector Signature: 'f Additional Notes: Clearly label any pictures and attach them to this form. Page 3 ..,- ..:3'ax,�_.. .�.,_ .. _....�msnry...,,,.-t.+... rs, -. _ ..,__ ,-r=..scxe .. ..��•,Y�..,--__ii a.,,.�?-._.ss« �, 1i11N.DIN6 EiwIVE3APf �� � 2S TOP OF FIELD SURFACE TO BE MOUNDED A -: f MIN. OF 6- ABOVE SURFACE GRADES b' SEPTIC ENVELOPE zS. Q}0j INSPECTION PORT (TYP) , t^ ILII// PERMANENT ERb$IDN Co "'4c AND LANDSCAPE; NAPDED, VEIIENTS INSTALLED EMBEDDED D5f)=72.-RIP RAR' r K . ON GRADED COMPACTED SLOPE P IMAILOCAIII."' z, SELECT BACKFILL AROUND PERIMETER' 3 �FcDR00M HOVE CONSISTING OF NON—EXPANSIVE SANDY i� APP pff F.F.EL=915 s SOIL COMPACTED IN 12 LIFTS T0rTTM91 GRAD 4- PERFORATED SDR-35 DISTRIBUT"- . Yp y{ PIPE INSTALLED ON BED BOTTOM .,.s SURFACE RUNNING TO CENTER EMy < 8t i CHAMBERS, CAP ENDS AND ORIENT I I ti' ORIFICES DOWNWARD AT 5 AND 7 O13[i6i 47 PERFORATED SDR-35 DISTRIBUTION . . PIPE INSTALLED ON BED BOTTOM i[. # SURFACE RUNNING TO CENTER OF END CHAMBERS, WITH CAP ENDS AND ORIFICEr ORIENTED DOWNWARD AT 5 AND 7 OCLOw' GiG NSTAL EO A 94' X 12• GRAVELLESS CHAMBER l�SOR�1N USED 45 STANDARD LEACHING CHAMBERS IN ROWS:TIF CHAMBERS PER ROW FOR A TOTAL ABSORPTION 6ER "Nil *- SQ. FT. LOCATION OF THE FIELD MEETS ALL OOUNTY`'% `y REQUIREMENTS. THE CHAMBERS IN THE BM WERE INVO LEVEL GRADE. THE SYSTEM IS PLUMBED FOR EQUAL"DIS f ;xy1 THROUGH A DISTRIBUTION BOX WITH INDIVIDUAL DISTRIBU CONNECTED TO THE EiEAD OF EAC"0VL STN LATERALS MiliE K[ALYEi! . m y9€k § CD 4. ENTL I 'r �bfl l+ 1 _ DISTRI 'n WITH BAFFLE D —=i^t; INSTALLED LEVEL PACTED B -�(- MARKED LOCATION WI D EBAR A$f �, • ; ^_ 5' ry L !! >; zs ,.es"... •!'."1' v r ..iui, r� � y' �`•`'r'�'%J'.'�`,a.�%�e'�'�'`, � l�, I'k < t � a ::!y •,.�+af.,...,o�....a,.we*.............,«-•::T.,-...... .....w..m.,�....a.w+.w+a,�.,.P..-..e....:. Uu�ywi w Ie- Tt -1-�v