HomeMy WebLinkAboutpitkin.eh.264535401002 (2000)Permit # 00037 Pitkin County Environmental Health Department Permit for an Individual Sewage Disposal System 130 S. Galena St. Aspen, Colorado 81611 Phone 970-920-5070 / FAX 970-920-5074 Parcel ID # 2645-354-01-002 Type of permit New( X ) Repair( ) Addition to House( ) Name of Owner Lois Pope Street Address Wildcat Ridge, Lot 2 ) 5d0 Property legal description Lot 2, Gentry Lot Split i Size of lot 199.9 acres Total square footage of the house 14,390 Water source ►E # of bedrooms in house 5 Caretaker unit attached # of bedrooms in caretaker unit Designed for what # rooms (list) Designed by Mailing Address Perc rate 28 Septic tank capacity # of offices, lofts & similar sized rooms in house 1 exercise room Total square fociage of the caretaker unit 1 # of offices, lofts & similar sized rooms in caretaker unit SEVEN (7): 5 BR's, 1 exercise room, 1 attached caretaker unit Permit information Church & Associates, Inc. 4501 Wadsworth Blvd., Wheat Ridge, CO 80033 Profile hole depth 5 ft 4,000 minimum Depth to groundwater or bedrock 5 ft bedrock Absorption area 3353sq ft, 30% chamber reduc = 2347 Comments Septic permit approved per compliance with the engineer design and specifications dated May 4 , 2000. Any changes must be approved by this department and the design engineer �rio_r to them being made. Minimum horizontal distances between components of the system and physical features shall conform to the Pitkin County ISDS regulations. One 2,500 gallon single compartment concrete tank followed by one 2,000 gallon two compartment concrete tank with duel pumps in a Biotube vault pressure distributed to two 4 ft deep sand mounds. Each bed to have 7 rows of 11 chambers (154 chambers total). The sand must conform to Section 12-5 of the Pitkin County ISDS regulations and an invoice to document the sand material must be submitted. This department does not endorse any brand of products. The engineer must do a final inspection of the installation and submit an as -built letter to this department. This department must also be called for an inspection with a minimum of 48 hours advanced notice. Permit approved by: ��- %ld c- Date: Lo 5 0CJ Plans and specifications of the pr osed individual sewage disposal system have been reviewed and are considered satisfactory. Permission is hereby granted to the owner or the agent to perform the work indicated in accordance with the Pitkin County ISDS Regulation in effect at the time of issue. This permit becomes invalid 6 months from the date that the permit was issued unless system construction has commenced or an extension has been approved in writing by the Department. As -built drawings must be included with this permit before the final approval will be issued. Installer: 1V3& ' Final inspection approval:-�c Sent By: Broome Construction Mgmt; 970 923 7341; May -23-00 9:14AM; MAY -23-00 TUE 08:00 AM ASI IFITKIN ENV HEATH FAX:970 920 I PAGE 2 ,ASPEN/PIT141N ENVIRONMENTAL HEALTH DEPARTMENT APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM 130 S. Galena St., Aspen Colorado 81611 Phone 970-920.50701Fax 970-920-5074 Name of OWNER Lois Pope Owner's Mailing Address 252 South Ocean Boulevard, Mana 1 apan , FL 33462 Business Phone: 516/547-9307 Boma Phone, 516/630-8644 Primary Contact Person (all communication regarding this permit will go through thts person) Name Paul Broome Company Norris & Associates Inc. Contact Mailing Address 5080 County Road 154, Glenwood Springs, CO 81 601 Business Phone; 970/945-44%ell Phone : 970/618-4810 Fax: 970/945-0141 Parcel ID # (available from assessor's orece 2 6 4 5 3 5 4 0 1 0 0 2 at 920-5160 or at www.aspen.corn/&ssessori) Street address of property Wildcat Ridge/Lot 2 Legal Description: Lot 2 ,Block .F+ling Subdivision Gentry Lot Spl i t Size of lot: 199.9 acres. Type of proposed structure: house Size of oldg. envelope Total square feet of house 14,390 # of bedrooms in house 5 # of offices, lofts & similar sized rooms in house 1 Caretaker Unit: Attached (} Detached -1 if bedrooms in caretaM 7.99 Total area(sq. ft.) of caretaker unit 1 0 of offices, lcfts and similar size rooms of caretaker unit Permit Is for: New Home ( X ) Repalr CU6 to failure ( ) Remodel/Addition ( ) Emergency use Water. Private well ( ) Spring ( ) Stream ( ) Community/Public Water System ( ) If community syst®m: Name of system Page 3 The fee for a ISDS application is $330 for a permit that takes 8 hours or less for the department to approve. If approval'takes longer than 6 hours, a rate of 355 per hour Mil be charged- The maximum fee is $1000. The basic fee of $330 is due at the time of application. The remainder, if any, will be due in two steges: first, at the time of issuance of the ISDS permit; second, before final approval of the 1808 permit. Application for an individual sewage disposal systy n is hereby submitted. I hereby certify that the above Information is true and accurate and that I have provided true end accur -� Information on locations of all existing and proposed wells, contour intervals, buildings, property lines, ditches, slopes, waterlines, springs, suction or Irrigation lines, drinking water cistems, drain tiles, irrigation ditches. lakes, water courses, strvarris, floodpiains, dry gulches, and existing septic systems. I hereby certify that any such features not shown on attached site map are not present. Issuance of the permit does not imply the approval of any other permit required for construction pursuant to Pltkln County codes. No construction may be undertaken until all approvals and permits have been obtained. The Aspen/Pitkin Environmental Health Department, Pitkin County and employees of these agencies will be held harmless should the individual sewage disposal system fall or malfunction. The permit to construct is issued on information submitted by the applicant or his/her representatives. The owner assumes full responsibility in case of failure of the system, Signature of applicant Date Received by - _J Receipt # 0__/- y Date 5 3 t G.\ehusds\Adsapp.doc D �� �D CHURCH & Associates, Inc. ENGINEERS & GEOLOGISTS January 30, 2001 Norris and Associates, Inc. Attn: Paul Broome 5080 County Road 154 Glenwood Springs, Colorado 81601 Subject: Installation Observations, Pope Residence Lot 2, Gentry Lot Split 1500 Ridge of Wildcat Pitkin County, Colorado Job No. 12422 Dear Mr. Broome, RECEIVED FEB 5 2001 PITKiN COUNTY ENVIRONMENTAL HEALTH As requested, we observed the installation of the onsite wastewater system (OWS) for the subject site on October 17, 2000, and January 26, 2001. The system was designed under our Job No. 12422, dated May 4, 2000. The system includes the installation of a 2500 -gallon, single -compartment, pre -cast concrete septic tank followed by a 2000 -gallon two-compartment precast concrete septic tank. Two pressure distributed mounded chamber -beds with imported sand filter material were installed for a total infiltrative area of 2387 square feet. A dual effluent pumping system and a filter must be installed based on our design criteria. Our office must be contacted upon the pump installation. A partial as -built drawing is included as Figure 1. The components of the OWS were installed in conformance with the plans and specifications. If there are questions or if we can be of further service, please call. Sincerely, CHURCH and Associates, Edward O. Church, P.E. EOC/trp 2 copies sent copy to: APEHD, Attn: Madelyn Blumenthal DENVER 4501 Wadsworth Boulevard Wheat Ridge, CO 80033 CASTLE ROCK 303.660.4358 303.463.9317 Fax: 303.463.9321 EVERGREEN 303.816.1455 LOVELAND 970.663.2124 115 7.9 ACRES LOT 2, GENTRY LOT SPLIT PITKIN COUNTY, COLORADO ONE 2500 -GALLON SINGLE COMPARTMENT PRECAST CONCRETE SEPTIC TANK FOLLOWED BY ONE - 2000 -GALLON TWO-COMPARTMENT PRECAST CONCRETE SEPTIC TANK. DUAL EFFLUENT PUMPING SYSTEM AND FILTER NEEDS TO BE INSTALLED SCHEDULE 40, 2 INCH PVC PUMP LINES WELL LOCATED 275+ FEET FROM DRAIN FIELD OWS AS -BUILT DRAWING JOB NO. 12422 SCALE 1" = 60' 2387 SF OF INFILTRATIVE AREA IN TWO PRESSURIZED GRAVELLESS BEDS WITH IMPORTED SAND FILTER MATERIAL 1/30/01 FIGURE 1 Sent By: Broome Construction Mgmt Inc; 970 922 1815; Jan -31-01 2:OOPM; 0� n JN¢ Page 6/8 F o ti J7 Z D r r -o r I I I Sent By: Broome Construction Mgmt Inc; 970 922 1815; Jan -31-01 2:OOPM; Page 7/8 0 Sent By: Broome Construction Mgmt Inc; 970 922 1815; Jan -31-01 2:OOPM; Page 8/8 0 y F7 a I�TDQ� �D(1] MSE m m N g Ps8 Y. 'a 9 W ' M4 uZi r "G D 2T�d A9 2 z E i n 0 i � L ;u: acv9 Vi ? P fl O of r; M := � cn v z E i n CHURCH & Associates, Inc. ENGINEERS & GEOLOGISTS May 4, 2000 Eric Smith Associates, P.C. Attn: Lou Thackston 1919 Seventh Street Boulder, Colorado 80302 Subject: Subsurface Investigation and OWS Design, Proposed Pope Residence Lot 2., Gentry Lot Split Snowmass Village, Colorado Job No. 12422 Dear Mr. Thackston, As requested, we have evaluated subsurface conditions at the site and designed an onsite wastewater system (OWS) for the proposed residence. Our firm investigated subsurface conditions on April 28, 2000. SITE CONDITIONS The property is located in a rural residential area in Pitkin County, where OWS are required. The proposed drain field area has a 3-5% slope to the east, and has a thick cover of native grass and scrub oak. The residence is served water by an onsite well, located 275+ feet from the proposed OWS. PROPOSED CONSTRUCTION The proposed residence will have a total of seven bedrooms and a living area of greater than 6000 SF. We have sized the OWS based on 7 bedrooms and 1820 Gallons Per Day (GPD) using Aspen/Pitkin Environmental Health Department (APEHD) loading of 130 gallons per day per person. The sewage loading with a peaking factor of 1.75 is 3185 GPD. This loading includes washing machines and a garbage grinder. SUBSURFACE CONDITIONS A subsurface investigation was performed by digging one profile pit 5 feet deep and 4 percolation holes, 17 to 23 inches deep, at the locations indicated on Figure 2. Subsurface conditions encountered in the profile pit consisted of 6 inches of root zone, underlain by sandy, silty, clay with Mancos Shale fragments to 1.0 foot, underlain by fractured Mancos Shale to the maximum depth explored of 5 feet, where refusal was encountered. Percolation tests indicate percolation rates of 5 to 10 minutes per inch (MPI). The average percolation rate is 8 MPI. Percolation data is presented in Table 1. Due to the sand filter material proposed we are sizing the OWS based on 28 MPI, or an application rate of 0.95 gals/SF/day. DENVER 4501 Wadsworth Boulevard Wheat Ridge, CO 80033 CASTLE ROCK 303.660.4358EVERGREEN 303.816.1455 303.463.9317 Fax: 303.463.9321 Subsurface Investigation and OWS Design Job No. 12422 Page 2 RECOMMENDATIONS The installation of two septic tanks, a duel effluent pumping system, and two mound chamber -type drain fields with imported sand filter material is proposed at the locations presented on Figure 2. The OWS design is based on an average sewage load of 1820 GPD and an application rate of 0.95 gals/SF/day. We recom- mend the installation of one 2500 -gallon single -compartment, precast concrete septic tank followed by one 2000 -gallon two compartment precast concrete septic tank with duel effluent pumps in a Biotube vault. Two pressure distributed, mounded drain field beds using chambers with 4 feet of imported sand filter material should be installed, as indicated on Figures 2 and 3. Six inches of topsoil should be removed and replaced on top of the mound to promote plant growth. The beds must have 7 rows of 11 chambers with 1.25 -inch PVC laterals suspended from the chambers, as indicated on Figure 3. The laterals should have 1/8 holes drilled on 4 -foot centers facing upward, with every fifth hole facing downward. The pump should be capable of a total flow rate of 46.1 gallons per minute, and a total dynamic head of 25.4 feet. Vehicle movement over the drain field bed area during construction should be kept at a minimum to prevent compaction of the receiving soils. The bottom of the bed should be scarified with a pick, shovel, or backhoe bucket teeth prior to the addition of chambers. The surface of the field should be seeded after installation of the fields. A native seed mix available at seed stores should be used. These mixes do not require irrigation and develop a growth 10 to 15 inches high. No automatic sprinkler system should be installed over the fields. OPERATION AND MAINTENANCE The owner must realize an OWS is different from public sewer service. The owner must be aware of and assume responsibility for maintenance of the system. In the absence of a monitoring program, we recommend the septic tank be pumped every two years. Effluent filter and screened vaults, as applicable, are to be cleaned during pumping. There are daily considerations such as not putting plastic or other nonbiodegradable materials into the septic system. Garbage disposal use should be minimized. The backwash of a water softener may be harmful to the OWS. A separate drywell should be constructed for the backwash waste, if a softener is installed. Chemically treated water from a swimming pool or spas should not be introduced to the OWS. LIMITATIONS An OWS design should be installed by a contractor who is experienced in its installation. Our investigation, layout, design and recommendations are based on data submitted. If subsurface conditions considerably different from those described in this report are encountered, we should be notified to evaluate the effect on the proposed OWS. If the health department makes modifications to this design, we should be contacted to evaluate the impact on the performance of the OWS. The county and our firm must be contacted upon completion of the OWS All construction is to be in accordance with the ISDS regulations. Pipe type and size, burial requirements, septic tank construction, and other specifications, which are not depicted in our report, are to conform to the requirements of the ISDS regulations. The installer of the system is to have demonstrated knowledge of the APEHD ISDS regulations and requirements. Subsurface Investigation and OWS Design Job No. 12422 Page 3 If there are question, please call. The project engineer for this project is Tim Petz. Sincerely, CIiURCIi& Associate OO REQ \ °D ° rye`''s • • . -rc Edward O. Church, ` s`S�ONAL �G\ EOC/trp 3 copies sent L 3unow ZZtZ G 'ON 9or NV-ld 31IS 1 I 1 1 1 v � A A o a I 3)N�IaISDH / W008038 N3A3S aDSOdOdd I OGVHoI00 `AINn00 NDllld JXldS 10-1 AUJLN3J `Z 10'7 S3UOV WL E z 3anou -Jd1831dW HDI -IIA ONdS GlidOdWl HIM S098 SS3-113AV89 03Z121nSS32id OMI NI VAHV 3AIl` di-IIdNl d0 AS LKZ S3 -10H N011b-10083d (INV lid 3IId08d j -j SMO ❑SSOdOHd ONd SFI-IOH NOIIVI0083d JO NOIIVO01 (1-1313 NIV80 (ASOdONd W08:4 1333 +SLZ 031Vo0l 1l3M -113M 0 ,09 4-ld7q 3A180 HIVIN38 (Mvid 38 Ol 3NFI dWnd :)Ad 07 3nw]HOS i-indA 38n1018 NI W31SAS ONIdWnd IN3fl-Idd3 -3nfl HIIM NNdl OIld3S IiAdDN0O ISdO321d iN3WidVdW00-OMI NOTIdO-000Z 3NO ,l8 43M070A �Ml OIld3S AEMNo0 1SVDDdd IN3WI2i'ddWOO 3PONIS NOIIdO-00SZ ANO ZZVZ L -ON 80r J,OOJ 1 --IVAH�IlNl dOOIN D 0(1Vd0-100 ')\1Nn00 NNIld 11IdS 10-1 AHINAJ 'Z 10-1 STJDV 6'L C- 0 O m Go rrl n _ O D n a r O r�ituirno o�Dmc -u o C wiz io -'$�F tD" ��0D--A �i�m Q z� �m� -0 >;U cn D ��� mC �Fic r rn r*1 o Z m N pp nC zp�M n pa -uCD Oma =i �� �� m D N DDz-uq K -no -1.1 Om (n :=I H r -Oz. O z N 7zC7Z>OM MYOW Z �c Oz— =�fm z04M mKaq "' vZ >mm zm l D y t'Tl �pz i m -nma) mp mwo m0�r z a • I CZ I --'a X w 0OZ H x�r r*�0m mmZ�z N1 �-u Wil\ �MO - z N m p moo, NXcn �-'� Z� ovocN.+c�i+ m - - - - - - - - - Opp I '� J �1 D m Jv rMCG)( stn ao -n 11 p �v � , Z-1 rr- D C~,+ -- j m r -i* z ter W rnp D ' �Z�o �nm OmD w moo O , r- z �a ; 00 2 "' II cn z z(/I'Z) �m(7 �O ppm Eliz` SMS -um K) O m� N m m 00 r�* D 1 O m cn 0a _ K�pc N p om - OX D 0 � ' zM ) a a� , a-Z1� rri Jnr Z D n a Or - COM , -0-11)mC' n A -1 n r? D Z X m D z no F �, -n ui a D , Z , "Tl m r ' , p m m w ro 70o D n n 0 C7 , r- m ;k . m r , M Z71 N ' � Cr � -i z M C C) tn m m- �•: a Z -D Z O < _ - - - - - - - - - - - "m' •' 0 c D Z C a z zo F IA b m D' m rm*7°� m 0 (1)mZ(�n-4(n ma a'. z'O1mcrir-CnZ � co r : Ul ri p r Zo o �tnrn�8 H -rp X =OMzZv�� J - ... oo mp'"�aDr� N -+ C 0�0ccZmD rj)�Dm-17oODr .:..:, . z oo m m in 2:K> O 0M ZC�r �r� �A=-0c M��z0D-i p �-tc�noo 0 C Z -<O pG) -Ti N z - i m D C C O m N CO m w 1 o r O Z C) N -Fa N N 2 0 n a N O O O SD a 0 3 (D (7 O O n CCD CD cn CD —I W 7c - D CD X CD 3 __ o V CD `' to �N cm sO • m 8 oZ� �cn N_ g C CL z tri � 09 S C N C " tS v o m � c CL ;� 3 to0 N 3 v o � o 2 0 n a N O O O SD a 0 3 (D (7 O O n CCD CD cn CD —I W 7c - D CD X CD 3 __ o V CD `' to �N cm sO • m 8 oZ� �cn N_ g C CL z tri � 0 b --1 r 0 < �r to D �m 0� n T� = C A -I o p Mn O 0 Q A O 0 S CD CL CD /TTAL+ 3a 0 mro (D (D N N N N Total Dynamic Head (f DH), feet T O C o g m �r ri �r tilt r►Qi r rrr :rrr fD Q .. N ID ro irri ■=ri ' h O O O O O O b Q1 b 0 CT w Co r'ii�i rrrr rrr �� I O O co O N N CO O O O O 3 b o M- R' m m m i6 m' m(D 0 a N O 0 m, m! m m m %a -,, 3 in 3 b O o r O T t, O o N cn ,Cr...rr...rr.�....r �..r..rr...r...�...r C G r .. ....r...rr...r ... rrrr �. , ...��..��•� �►��. C��.r�.�..rrr.r... �S .,r r►�r r,ri�r�r �i��i%.Pi�rr�i�iiir�iiiirurr�rrurr�■�ir ;•..pry rrrrr■� No No rrrr ■� nr�r T -0 r -i CD N a S 0- o CD o n ❑ 3 S m Z Z �. kc) N o o ro _^ c c 3< 3 c w pa 3 a c 0 n Q_ D C) N �' = O O 0 ]! V+ �0 -i o O p° Q w 2 m o s= a 0� r Q �^ D= c ro �D -{ Q tz ai m °- O r 0- r c) �� 1 r O ro �7 (A 9 1 K D M r- m M 0 m r o p N O m r = w f3 3' N� -0m o 3 O ak O N m r O D a® a 11 'LI ro O lD Q U1 EP U1 (/J P N 2 p M N O0 ' ro ro a y Q U. ro rn 3-0 N _ O' ro o o Ji m lD n U1 ror N a cn (D o cn Co o(D O 4. Q LO r) N ro Q S -6 M n' O m ro- N - 3 3 a C m r i' ro 0- C m` N [D zr lD N N ro Q N. 3 la `s f7 m m N' CD CL CD /TTAL+ 3a 0 mro (D (D N N N N Total Dynamic Head (f DH), feet T O C o g m �r ri �r tilt r►Qi r rrr :rrr fD Q .. N ID ro irri ■=ri ' h O O O O O O b Q1 b 0 CT w Co r'ii�i rrrr rrr �� I O O co O N N CO O O O O 3 b o M- R' m m m i6 m' m(D 0 a N O 0 m, m! m m m %a -,, 3 in 3 CD CL CD /TTAL+ 3a 0 mro (D (D N N N N Total Dynamic Head (f DH), feet T O C o g m �r ri �r tilt r►Qi r rrr :rrr irr �rr■�r r rr _ irri ■=ri ' rrrr _ �� - rrrr r ii rrrr�i � rrirIMirrrri�irrrrr'irrrr r ■�rrrrirr�rr�r�r� ��r�l�r rr��rrrr� rrr rrr�r�r rr MEN � ■�ir��r rrrr 0NO _ rr �rr r'ii�i rrrr rrr �� I : ■� rrrrr rrrr No No r rrrr rrr//r r� r�r� r■�C■�■�■�r�r�'��r'ri'►.irr�■ �-roi O O 3 b o N OO 0 1 Co 0 AIL 0 N 0 N O 0 .la 0 N O 0 N O OM 0 --` 0 b O o r O T t, O o N cn CD CL CD /TTAL+ 3a 0 mro (D (D N N N N Total Dynamic Head (f DH), feet T O C o g m �r ri �r tilt r►Qi r rrr :rrr irr �rr■�r r rr _ irri ■=ri ' rrrr _ �� - rrrr r ii rrrr�i � rrirIMirrrri�irrrrr'irrrr r ■�rrrrirr�rr�r�r� ��r�l�r rr��rrrr� rrr rrr�r�r rr MEN � ■�ir��r rrrr 0NO _ rr �rr r'ii�i rrrr rrr �� I : ■� rrrrr rrrr No No r rrrr rrr//r r� r�r� r■�C■�■�■�r�r�'��r'ri'►.irr�■ �-roi r�rri�rrr rr �� rrr�r.....r /rrrr rrr�ir�rr�ir rr r r rrr ►,-rrr, M rrr r//rrr M r r rrir.rrrrr►.. r PAVrrrr ,Cr...rr...rr.�....r �..r..rr...r...�...r r .. ....r...rr...r ... rrrr �. , ...��..��•� �►��. C��.r�.�..rrr.r... �S .,r r►�r r,ri�r�r �i��i%.Pi�rr�i�iiir�iiiirurr�rrurr�■�ir ;•..pry rrrrr■� No No rrrr ■� nr�r Profile: T,k.jLE 1 - PERCOLATION TEST RES.,LTS LOT 1, GENTRY LOT SPLIT DATE OF TEST: 4-28-00 SNOWMASS VILLAGE, COLORADO isef A -n ^ ^fir%n 0 - 6" Root Zone, Sandy, Grey/Brown 6" - 1' Clay, Sandy, Silty with Mancos Shale Fragments, Stiff, Moist Grey/Brown 1'- 5' Fractured Mancos Shale, Medium Hard, Moist, Grey - REFUSAL@W NO GROUND WATER WAS ENCOUNTERED WITHIN THE EXCAVATION AVG. HOLE DEPTH TIME DEPTH DEPTH CHANGE, INTERVAL HOLE NUMBER OF HOLE, INTERVAL START, END, (INCHES) PERC PERC. (INCHES) (MINUTES) (INCHES) (INCHES) RATE (MPI) RATE, IMPI► NUMBER OF HOLES AVG PERCOLATION RATE (MPI); 8 Job No. 12422 ■■� ■m�®as® ;; , ■mom NUMBER OF HOLES AVG PERCOLATION RATE (MPI); 8 Job No. 12422 Profile: TABLE 1 - (cont) PERCOLATION TEI'fRESULTS LOT 1, GENTRY LOT SPLIT DATE OF TEST: 4-28-00 SNOWMASS VILLAGE, COLORADO 0 - 6" Root Zone, Sandy, Grey/Brown 6" - 1' Clay, Sandy, Silty with Mancos Shale Fragments, Stitt, Moist Grey/Brown 1' - 5' Fractured Mancos Shale, Medium Hard, Moist, Grey - REFUSAL 5' NO GROUND WATER WAS ENCOUNTERED WITHIN THE EXCAVATION AVG. HOLE DEPTH TIME DEPTH DEPTH CHANGE, INTERVAL HOLE NUMBER OF HOLE, INTERVAL START, END, (INCHES) PERC PERC. (INCHES) (MINUTES) (INCHES) (INCHES) RATE (MPI) RATE, IMPII NUMBER, OF HOLES: 4 AVG PERCOLATION RATE. (MPI): 8 Job No. 12422 Mai 24 00 11:43p CHURCH & Rssocaties 303-4G3-9321 ASPEN/PITKIN ENVIRONMENTAL HEALTH DEPARTMENT ISDS DESIGN CALCULATIONS Owners Name f1Q.FFi� ` t x ZF F. Pfie* t C�dZ arcel ID # ?R+:r"�4;•�i House Size (sq. ft.) *60l� (75 gpd, 100 gpd, or 130 gpd) 130 Number of Bedrooms in Main House Number of Offices, Libraries, Studies, Similar -sized Rooms in Main House Number of Bedrooms in Detached Caretaker unit Number of Offices, Studies, Similar -sized Rooms in Caretaker Unit:`s tj (If the caretaker unit is ATTACHED, treat as if part of main house.) Average Daily Waste Flow 1820 State Review Required? no / Perc Rate h , ;$ (i) - USING 0.95 APPLICATION RATE DUE TO SAND Design Flow (Q) = # potential bedrooms X 2 people/bedroom X gpd X 1.75 Q= 3185 Absorption Area (A= Q/5 X SQRT) A = 3353 sq. ft. of absorption area required 216 infiltrator units without reduction A maximum 30% reduction is allowed for use of deep gravel or gravelless chambered system, only if the lot size anti soil conditions are optimal. If a reduction is being proposed, describe why lot size and soil conditions are optirnal: PRESSURE DOSING SAND FILTER MATERIAL A = 2347 sq.fL with reduction 151 infiltrator units with reduction Type of system: BAbsorption trenches BAbsorption bed [x] Gravelless chambers Dry well []Seepage Pit 00ther Minimum tank capacity SETBACK FROM WELL # of feet = 274.8 3981 gallons . �. i SETBACK FROM POND, STREAM OR IRRIGATION DITCH # of feet = 224.8 SETBACK FROM DRY GULCH # of feet = 199.8 FINAL INSPECTION BY: DATE: p.1 .0.. *o1� Engineer's Submittal for Septic Permit in Pitkin County Owner's Last Name: POPE Location: Lot 1, Gentry Lot Spilt Summary of information regarding new septic system: Type of system being proposed: SEPTIC TANK AND MOUND GRAVELLESS CHAMBERS Other treatment processes being used: NONE Does the system use any mechanical parts? (Prohibited unless there is no alternative)YES If yes, explain why there are no alternatives A PUMP IS REQUIRED DUE TO PRESSURIZE THE FIELDS Does the system require any maintenance other than routine pumping? YES If yes, who will do the maintenance? CLEAN FILTER WHEN SEPTIC TANK IS PUMPED Are any reductions being proposed? YES If yes, what makes the lot and soil conditions optimal? PRESSURE DOSING SAND FILTER MATERIAL USING INFILTATORS Which of the following are on the site or within setbacks? Closest distance of septic system to each feature [] 100 year floodplain N/A [] well(s) 275 FEET (] irrigation ditches N/A [] streams N/A Q ponds NLA [J other features NLA What was the profile hole depth? 5 FEET What is the depth to groundwater? N/A What is the depth to bedrock? 1 FEET What assumptions, if any, were made in system sizing and design? (Include any local, site- specific data, such as months without snow cover, ratio of evaporation to absorption, etc. that are relevant.) If there are any variations from normal design, please explain how they can be demonstrated to improve treatment and protect water quality. NONE MAY- 5-00 FRI 9:33 AM SHELTON DRILLING CO FAX N0, 9709273301 WELL CONSTRUCTION AND TEST REPORT FOR OFFICE USE ONLY STATE OF COLORADO, OFFICE OF THE STATE ENGINEER 1. WELL PERMIT NUMBER MH -36501 2. Owner Name(s) Lois Pope Mailing Address 252 S. Ocean Blvd. City, St. Zip : Manalapan, FI. 33462 Phone ( ) - APPROVAL # GWS31-91-03 3. WELL LOCATION AS DRILLED: NW 1/4 SE 1/4 Sec. 35 Twp. 09S Range 88W DISTANCES FROM SEC. LINES: 1648 ft. from South Sec. line. and 2391 ft. from East Sec. line. OR SUBDIVISION : LOT BLOCK FILING(UNIT) STREET ADDRESS AT WELL LOCATION: 4 GROUND SURFACE ELEVATION ft. DRILLING METHOD Air Rotary DATE COMPLETED 07/08/99 TOTAL DEPTH 260 ft. DEPTH COMPLETED 260 ft. 5. GEOLOGIC LOG 6. HOLE DIAM. (in) FROM (ft) TO (ft) Depth Type of Material (Size, Color, and Type) 9.0 0 28 000-002 Topsoil 6.5 28 260 002-260 Mancos Shale - 7. PLAIN CASING OD (in) Kind Wall Size From (ft) To (ft) 7.0 Steel 0.240 -1 28 i 5.5 PVC 0.250 20 180 PERF. CASING : Screen Slot Size: 5.5 PVC .250 180 260 - -- -- ---- - - 8. Filter Pack 9. Packer Placement Material : Type WATER LOCATED 180,200+ Size : Depth Interval: REMARKS: 10. GROUTING RECORD Material Amount Density Interval Placement cement 3 sks 16 gal 8-28 poured HTH Amt. -Used: 2 oz. 11. DISINFECTION : Type 12. WELL TEST DATA : [ ] Check Box If Test Data is Submitted On Supplemental Form. TESTING METHOD : Air Compressor 165 ft. Date/Time Measured 07/08/1999 Production Rate 15 9Pm Static Level : Total ft. Date/Time Measured 07/08/1999 Test Length 2 hrs. pumping Level fey ere true to my k wwlodga. (Pucs44 10d (13)(a) CRS, the mak ng of false statemerrts coni y Remarksuont to Section 2 _ 13. perjury ft sem nts rr ane Pu'nlshade as a dassnl m sdem alnor Phone : (970) 927-4182 CONTRACTOR Shelton Drillin Corp. Si natu Name / Title (Please Type or Print) 9 Date 07/14/99 Vva ne ,3ntrlwn i ir;13� Apr 24 00 08:54a CPURCH & Assocaties 303-463-9321 NANCY I CAA -?LA 1 HE fot.t.owING- --\,p)-j5 N'R6 6PEN Atv-\") -DRIS VOLL LADE' L�-c'�LE ECIC C.K, S�SpI*11SIot�.j r \ X3.jr%EQin «K J --Y-� �- NE`s �s Av (t11,141� f M as W6. � Ili 05�� 0 p.l 0 BON 500 Fi5 4Z4 RESOLUTION Or THE PITKIN COUNTY PLANNING AND ZONING COMMISSIQN . GWITING 1041 ENVIRONMENTAL HAZARD APPROVAL W m U TO THE LANGE 1041 APPLICATION < C4 N Resolution No. PZ -89-,/y C:) » :J ^v o ._ N x N dba Aspen Panorama C13WHE&EAS,oc The Lange Partnership, P a Development Company (hereinafter "Applicant") has applied to the Planning and Zoning Commission of Pitkin County, Colorado, (hereinafter "Commission") for approval of a 1041 Geologic, ';. 4;ildlif. and Wildfire Environmental Hazard Area Review, pursuant J to Section 5-400 of the Pitkin County Land Use Code; and WHEREAS, the Lange parcel is 400 acres in size and located . northwest of Snowmass Village in Section 2, Township 10 South, Range 86 West and Section 35, Township 9 South, Range 86 West, . more specifically described.in Exhibit 'An, and l I i WHEREAS, the Applicant proposed to construct a driveway and rJ underground electric and telephone utilities within the driveway, to access said parcel; and S at a duly noticed public hearing on March 7, 1989, ' WHEREAS, Y r the applicant agreed to amend the proposal at the request of the ` Commission and the County Attorney, to include a building envelope for the parcel to enable the Commission to approve the primary use on the property (building envelope) concurrently with j the accessory use (driveway); and WHEREAS, the Commission reviewed the amended application at public hearing on March 28, 1989, and at that time a duly noticed p , evidence and testimony was presented with respect to the Resolution No..PZ �., .... Page' 2 application; and WHEREAS, the Commission finds that the applicant. has complied with the criteria for a 1041 Geologic, Wildlife and Wildfire Environmental Hazard Area. NOW, THEREFORE, BE IT RESOLVED by the Commission that it does hereby grant 1041 Hazard Review approval to the Applicant subject to the following conditions: �i. 1) Approval of the building envelope and access road by Pitkin County does not grant nor represent any zoning rights for the 400 acre Lange parcel; other the.n those rights for the underlying RS -30 zoning of the property as set forth by The Pitkin County Land Use Code.. 2) The applicant shall comply with recommendations made by Nicholas Lampiris regarding driveway. design in his letter of December 1, 1989, which are as follows: a) A suitably sized culvert (as determined by County Engineer or a civil engineer) shall be placed in the road where it crosses the out flow drainage below the dam for the Ziegler gond. b) Where the road parallels the northern drainage on the Ziegler Property, it shall be outside of the bog -type vegetation to the northeast and, where possible, be designed carefully for. the Mancos soils which Asn be troublesome, especially near the drainage. Minimal bar ditches on the uphill side of the road and water bars may be used for drainage. C) A cut only design rather than a cut and fill, design shall be incorporated in the des?gn of the traverse of the steep slopes on the upper end of the drive. d) Retaining structures or boulders, (as determined by County Engineer or civ,' -:L -engineer), shall be placed on t'1e uphill cut of the steep traverse. 3) Wildfire mitigation shall be as follows: a)An external wlcer supply for fire fighting shall be provide --d (small pond, cistern, well or eooK U ,)r qac. �x�/� , r application; and WHEREAS, the Commission finds that the applicant. has complied with the criteria for a 1041 Geologic, Wildlife and Wildfire Environmental Hazard Area. NOW, THEREFORE, BE IT RESOLVED by the Commission that it does hereby grant 1041 Hazard Review approval to the Applicant subject to the following conditions: �i. 1) Approval of the building envelope and access road by Pitkin County does not grant nor represent any zoning rights for the 400 acre Lange parcel; other the.n those rights for the underlying RS -30 zoning of the property as set forth by The Pitkin County Land Use Code.. 2) The applicant shall comply with recommendations made by Nicholas Lampiris regarding driveway. design in his letter of December 1, 1989, which are as follows: a) A suitably sized culvert (as determined by County Engineer or a civil engineer) shall be placed in the road where it crosses the out flow drainage below the dam for the Ziegler gond. b) Where the road parallels the northern drainage on the Ziegler Property, it shall be outside of the bog -type vegetation to the northeast and, where possible, be designed carefully for. the Mancos soils which Asn be troublesome, especially near the drainage. Minimal bar ditches on the uphill side of the road and water bars may be used for drainage. C) A cut only design rather than a cut and fill, design shall be incorporated in the des?gn of the traverse of the steep slopes on the upper end of the drive. d) Retaining structures or boulders, (as determined by County Engineer or civ,' -:L -engineer), shall be placed on t'1e uphill cut of the steep traverse. 3) Wildfire mitigation shall be as follows: a)An external wlcer supply for fire fighting shall be provide --d (small pond, cistern, well or NucK�.) tesolution No. PZ -997L )age. 3 hydrant); b) The Applicant shall thin or clear any trees or shrubs as necessary within 3o feet of the proposed residence; 4) Z, 6) ' 7) C) All roofs shall be kept cleared of debris; d) Firewood shall. be stacked on a contour away from .building; e) The base of buildings shall be kept clearer: of weeds and debris; f) At least one (1) ten -pound ABC -class fire extinguisher shall be placed in each structure; g) Roof covering shall be of a non-combustible underwriters laboratory approved material; h) All power and telephone lines shall' be underground; and i) No structures shall be placed on densely vegetated hillsides with slopj:s greater than 30%. Wildlife Concerns shall be mitigated as follows: a) All dogs shall be kenneled; . b) Maintain native vegetation outside of developed area; and C) All fencing shall be 42" or less in height, and 4 strand or less. Prior to building permit: issuance, the applicant shall apply for an Encroachment Permit from the Pitkin county Engineers Office. As required by the Town of snowmass village, the applicant shall share a proportionate responsibility for any future upgrading of Campground Divide Road as 'to sufficiently address traffic at the time they intend to may be necessary impacts evident in that area develop their land. An effort shall be made by the applicant to minimize the area of soil disturbance, preserves existing tree cover., and to re -vegetate in the area of road construction whercv,~:r possible. - \r • �fi: ..a�. � 'u ii�r..':�L..e�;:hr: fir•, y.e ��N yr wy<` wi v�X'.; e.- . resolution No. PZ -89- C 'age 4 In the event that this application is amended or the driveway alignment modified, The Town of Snowmass shall be notified and allowed to comment. The applicant may modify the proposed driveway alignment to cross the adjacent Snowmass Land Company parcel as depicted on Exhibit B, and as shown on the recorded 1041 Plan, should an easement from Snowmass Land company be obtained for said alignment. Should the access easement br adjusted the applicant adjacent Snowmass Land company parcel, shall obtain Special. Review Use approval from the Town of Snowmass village prior to construction of that road segment. Septic system design shall be approved by Pitkin County Environmental Health Department prior to building permit. issuance. Well water quality shall be approved by Pitkin County Environmental Hez.lth Department prior to building permit issuance. The proposed residence shall be allowed one fireplace and one certified wood stove and shall comply with applicable Pitkin .County Air Quality Regulations in effect at the time of building permit issuance. County noise r'�gulations shall be adhered to during construction of the proposed residence pursuant to Section 2-23 of the Pitkin County Land Use Code. APPROVED by the Com.nission at its regular meeting on March 28, 1989• ATTFST: / Jeanette Jones; Deputy county -Clerk PITKIN COUNTY PLANNING AND ZONING COMMISSION By an eter Dobrovolny, hairin 01 : . I I I - , - Mi, IWO Ex,q iVT - LEGAL DESCRIPTION ction 2, Township 10 South, Range Wec:t A tract Of land located in Se 13C, 4Icst of the Gth Principal Township 0 30uth, Ran9c Said Tract is more fully . ..... and Section 35, Colorado. Meridian, County Of Pitkin, State Of col described as follows: Beginning at the Southeast corner of Section 35, thence North 0*00'37" East 3446.81; thence West 3474.12 feet: south .0-00 13711 West 5795-00 feet; thence 266.43 feet; thence North 89*5913411 East thence North 22*50135" East 337-99 feet; thence North 79'35'351, East 426.73 feet; East 338-50 feet; thence North 66.49'35"349.67 feet; thence North 57*59135" East feet; thence North 74*5912311 East 783.43. thence Nortl%'W4310111 East 617.27 feet; 'North es*07 1 4311 East 820-22 feet; to the point of beginning. thence L,*001:3711 East 1013.06 feet thence North, COUNTY OF PITKIV, STATE OF COLORADO 11 -qw Resolution No: PZ-89- �'- Page 5 APPROVED AS TO FORM: L County Attorney ELS e_1041 reso lang 1 APPROVED AS TO CONTENT: zcjr . _Ilan Richman irector Planning i I G 1 i i. � Hand Delivered Dear Nancy: As we discussed by phone, I am writing on behalf of Richer Investments, Inc., owner of both Lot 1 and Lot 2 of the Gentry Lot Split as amended (the "Subdivision") regarding the earthmoving permit application for a lined pond for Lot 2 which I filed on September 29, 1998. I am submitting information provided to me by E. O. Church, Inc., Engineers and Geologists, regarding the engineered septic system for the proposed structure on Lot 2. This information has not been formally submitted for a septic permit because we are not yet in a position to address some of the submittal requirements from your checklist. One well has previously been completed within the Subdivision which has been tested and produces between 10 and 12 gallons of water per minute. The owner intends to complete a second well on Lot 2 in the future. However, the owner currently has the right to use the existing well to serve up to three homesites on the property (the two 200 acre lots are presently both vacant). Therefore, I am also supplying information about the existing well on the property for your information. In my opinion, there is no rational nexus between an application for an earthmoving permit for a pond of roughly 0.6 acres in size and the requirement to obtain a septic permit for a residence which will be proposed in the future. That is particularly the case in this situation, where the lot is 200 acres in size and the building envelope previously approved by Pitkin County is at least 8 acres in size. The septic system for the future residence has been engineered by a licensed engineer, who has concluded that a leach field of only roughly 2,000 square feet in size will be required in the location designated on Figure 2 of his report in order to fully comply with current County regulations. T � Gl-oa Z Joseph Wells Land Planning, Inc. 602 Midland Park Place Aspen, Colorado 81611 Phone: 970.925.8080 Facsimile: 970.925.8275 November 4, 1998 E I'll NOV U 5 1998 s+ i s Ms. Nancy Mackenzie HEAL"± H Pitkin County Environmental Health ASPEN PITKN 130 South Galena Aspen, CO 81611 Hand Delivered Dear Nancy: As we discussed by phone, I am writing on behalf of Richer Investments, Inc., owner of both Lot 1 and Lot 2 of the Gentry Lot Split as amended (the "Subdivision") regarding the earthmoving permit application for a lined pond for Lot 2 which I filed on September 29, 1998. I am submitting information provided to me by E. O. Church, Inc., Engineers and Geologists, regarding the engineered septic system for the proposed structure on Lot 2. This information has not been formally submitted for a septic permit because we are not yet in a position to address some of the submittal requirements from your checklist. One well has previously been completed within the Subdivision which has been tested and produces between 10 and 12 gallons of water per minute. The owner intends to complete a second well on Lot 2 in the future. However, the owner currently has the right to use the existing well to serve up to three homesites on the property (the two 200 acre lots are presently both vacant). Therefore, I am also supplying information about the existing well on the property for your information. In my opinion, there is no rational nexus between an application for an earthmoving permit for a pond of roughly 0.6 acres in size and the requirement to obtain a septic permit for a residence which will be proposed in the future. That is particularly the case in this situation, where the lot is 200 acres in size and the building envelope previously approved by Pitkin County is at least 8 acres in size. The septic system for the future residence has been engineered by a licensed engineer, who has concluded that a leach field of only roughly 2,000 square feet in size will be required in the location designated on Figure 2 of his report in order to fully comply with current County regulations. T 11-05-1998 03:09PN rkON E 0 CHURH INC E.O. CHURCH, INC. ENGINEERS & GEOLOGISTS September 10, 1998 TO 19709258275 P.02 Norris a Associates Attention: Jack Martin and Rex Echo P.O. Box 5759 Snowmass Village, Colorado 81615 Subject: Subsurface Investigation and OWS Design, Richer Residence Lot 2, Gentry Lot Split as Amended Pitkin County, Colorado Job No . 10006 Dear Messr. Lakeman and Echo, As requested, we have investigated subsurface conditions at the site and designed an onsite wastewater system (OWS) for the proposed resi- dence. The purpose of the subsurface investigation was to determine design parameters for the OWS design. SITE CONDITIONS - The lot is located in a rural area in Pitkin County, Colorado. The proposed drain field area has a moderate slope. There is a moderate cover of grasses, sagebrush, and scrub oak at the proposed field. PROPOSED CONSTRUCTION - A three-bedroom residence with greater than 6000 square feet (SF) of living area is proposed at the location presented in Fig. 1. The sewage loading for a three-bedroom residence is 780 gallons per day (GPD) using Aspen/Pitkin County Environmental Health Department (APCEHD) loadings of 130 gallons per day per person. The sewage loading with a peaking factor of 1.75 is 1365 GPD. This loading includes a dishwasher, garbage grinder, and washing machine. The residence will be served water by an onsite well, which should be located greater than 129 feet from the proposed drain fields. A pond is proposed near :the drain field area. The pond must be located greater than 79 feet from the proposed drain fields. SUBSURFACE CONDITIONS - The subsurface investigation was performed by observing two backhoe pits and performing 13 percolation test. Profile pits indicate subsurface conditions consist of residual clay to 1 foot, underlain by weathered fractured shale bedrock to the maximum depth explored of 4.5 and 5.5 feet. Backhoe refusal was encountered at 4.5 to 5.5 feet in Profile I and Profile 2, respectively. The backhoe pits were excavated with a light duty rubber -tired backhoe similar to a Case 580- No ground water was encountered. Percolation holes were excavated with a two man, gas powered auger due to access and wanting to save vegetation. The percolation holes were drilled into the fractured bedrock and bottomed where auger refusal was encountered. Percolation test performed near Profile 1 indicated percolation rates of 20 to 40 minutes per inch (MPI). The average percolation rate is 23 MPI. percolation test performed near Profile 2 925 East 17th Avenue • Denver, Colorado 80218-1407 P.O. Box 2869 • Evergreen, Colorado 80437-2869 (303) 832-9692 FAX (303) 832-3517 (303) 674-0660 FAX (303) 674-0813 OPERATION AND MAINTENANCE - The owner must realize an OWS is different from public sewer service, and must assume the responsibility for maintenance of the OWS. The system is relatively maintenance free, but the owner must have the septic tanks pumped. We recommend the .• septic tank be pumped every two years. There are daily considerations, such as not putting plastic or other nonbiodegradable material into the OWS. Water use must be monitored so toilets are not allowed to run when seals malfunction. To illustrate the point, a running toilet can consume in excess of 1000 GPD. An excess 1000 GPD loading could flood and irreparably harm the OWS and stress the onsite well. We caution against installation of a water softener. The hydraulic loading from the backwash of a water softener may be detrimental to OWS and a separate drywell should be constructed for the backwash waste, if a softener is installed. Chemically treated water from a swimming pool or spas should not be introduced to the OWS. LIMITATIONS - An OWS design requires installation by a contractor who is experienced in its installation. Our investigation, layout, design and recommendations are based on data submitted. If subsurface condi- tions considerably different from those described in this report are encountered, we should be notified to evaluate the effect on the proposed OWS. If modifications to this design are made by the health department, we should be contacted to evaluate the impact on the performance of the OWS. All construction is to be in accordance with the ISDS regulations. Pipe type and size, burial requirements, septic tank construction, and other specifications, which are not depicted in our report, are to conform to the requirements of the ISDS regulations. The installer of the system is to be licensed by the APCEHD and is to have demonstrated a knowledge of the ISDS regulations and requirements. If there are any questions, or if we can be of further service, please call. Sincerely, E. O. CHURCH, INC; Edward O. Church, IK:E. EOC/cbs 3 copies sent cc: Bill Poss and Associates, Attention: Cary Lakeman i 11-04-1998 01:03PM FROM E 0 CHURH INC TO 19709258275 P.03 I_ U 1 C PITKIN COUNTY, COLD PROPOSED RESIDENCE NORTH SCALE !f =100, PROPOSED rl" %r';:J';r. r. ,;, r.: ,r-r.r,-• ' d OURS SHED � f� , 1 i• ,,) .,,•.-' ff 3r. I � !'fil, ,itL llt�;i: l�j �I:'I lll•"J', t.., J!l tlJ ,lit ',isi, '1 Vii{ '77". .�• ,r'!' r:;ri,�jr'. :.I.�r•�'If/•!!):,fry PROPOSED RETAINING WALEIiif,a .-,•fG,� avr?:e �'•'`i i P�?'Jfe r p,�. i}dr;lfaJ/r`:'r fr/'1 iJ!�If. 11t1t''ti'1',; NOTES 1. SITE PLAN SUPPLIED BY B L POSSE E i�,'•`�''�. ?� & ASSOCIATES. iii � � j ! i i' . ,`��I{b; 7. �; •' ' PROTPr .1 t 4 � lSt .-', SSV' l ��i±� •, .��: :'::• PRCIPOSED r- POND EXISTING JEEP ` D VE ROAD U DER C NSTRUCTI❑N SITE PLAN AND L ATI❑N OF PARC❑ ` t]N AND PROFI E HOES JOB NO 10006 FIG. 1 r f O 11-04-1998 01:03PM qON E 0 CHURH INC TO 19709258275 P.04 i LOT 2 PITKIN COUNTY, COLOY-A O 2000 GALLON TWO -'r t COMPARTMENT PRECAST CONCRETE SEPTIC TANK WITH A PUMP IN A BIOTUBE VAULT AND PRESSURE ✓, r RELEASE VALVE \11"X., 0 it r NOTEi ` 1. WELL IS TO BE LOCATED WEST PROP17SED CABIN WHICH IS GREATER THAN 129' FROM PROPOSED DRAIN FIELDS. rfrl !l =I r11 SQT ;1 CALL RTH r 60' f f •; + f! j,r�rrrr�ifi�tlff�/i tf�1f1j1'1 i ift+�lirr ,. r+r.' `,!� lf�i'Iir'!ir• ' ��+:I' CONTOURS r' ' 1 <r ri ! r t ; rri + i f j l i t ' t Z?; ' ,f.'; •'!r` /�.✓ / r r'r ri !` ` 1 : r�`%/✓i>if i�Ji + ''ffi!rr r'iYra(1rT F +r'��it +•erf +J'r,�f/!l �Q'r.� ,/Jr t .!!,%k�'�, • i./ 1';l�: .t �, rtrr % l+Jfl� f J 1 r f!i • j ' i., ,r � �f r � r rr !j r {' l i JOB NO. 10006 LOCATION gFw--PREIPO ED 1• t SCRUB OAK FIG. 2 TOTAL P.04 2' INCH PVC PIPE INSTALLED NOW- WITHOUT LOW PRINTS 1 i f/ PRESSURE DISTRIBUTED � DYER -EXCAVATED„ CHAMBER BEDS THREE - 6' X 31.5' - A r a3 �3a 2 ROWS OF 5 CHAMBERS HREE - 6' X 37.75 - B ROWS OF 6 CHAMBERS JOB NO. 10006 LOCATION gFw--PREIPO ED 1• t SCRUB OAK FIG. 2 TOTAL P.04 TYPICAL PLAN VIEW ENDS CAPPED 3' OR 4' PVC ---- OBSERVATION/VENT PIPES 1/8- WEEP IN BOTTOM OF 1.25- LATERALS TYPICAL END VIEW NATURAL GRADE J� SEE BELOW I , 6' 6' MIN. 2" MANIFOLD -j 6' MIN. DESIGN CALCULATIONS GRAVELLESS CHAMBERS "-SUSPEND DISTRIBUTION PIPES PER MANUFACTURER RECOMMENDATIONS: 195' PVC WITH 1/8' HOLES FACE UP EVERY 3' 3" OR 4' PVC OBSERVATION/VENT PIPES SLOPE FOR ., ., rQ AIM A( -J-- il SAND FILTER MATERIAL CALCULATIONS STRUCTURE - 3 BEDROOM RESIDENCE. >6000 SF LOADING - 130 GPD PER PERSON TOTAL LOADING - 0 = 780 GPD PERCOLATION RATE - T = 17 MPI AREA - (175 X 0 X -4T)/5 TOTAL AREA - 1125 SF SAND FILTER APPLICATION RATE - 0.95 GPD/SF AREA - (1.75 X 0)/ 0.95 GPD/SF TOTAL AREA - 1437 SF REDUCTION FOR CHAMBERS - 30% TOTAL AREA - 1437 SF X .7 - 1006 SF PROPOSED SEPTIC TANK CAPACITY 15' 6' -4 DISTRIBUTION MANIFOLD WITH INLET AND OUTLETS PERPENDICULAR TO MANIFOLD uu GRAVELESS CHAMBERS SAND FILTER SPECIFICATIONS! 'CONCRETE SAND" 0.6 mm < 10 Cu < 4 SAND FILTER MATERIAL MUST BE APPROVED BY ENGINEER PROPOSED FIELD AREA LENGTH - A - 31.5 FT. 5 CHAMBERS - B - 37.5 FT. 6 CHAMBERS WIDTH - A - 6 FT. 2 CHAMBERS - B - 6 FT. 2 CHAMBERS NUMBER OF BEDS - A - 3. B - 3 CHAMBERS PER BED - A - 10. B - 12 TOTAL CHAMBERS - 3 X 10 * 3 X 12 = 66 PROPOSED AREA - 66 X 15.5 CHAMBER/SF =1023 SF TOTAL CAPACITY - L75 X 0 X (30 HOURS/24 HOURS) = 1706 GALLONS RECOMMEDATION - 2000 GALLON TWO COMPARTMENT PRECAST CONCRETE SEPTIC TANK WITH A PUMP IN A BIOTUBE VAULT cw J08 N0. 10006 FIELD DETAILS FIG. 3 Cf) � C/) C -D O � U CD z LLJ — CD z � V) w U LLJ Z_ O CD z LLI w Q c u qm i C')t GO !� oEZ « LLJ \® k f / _ _ 3 ) 2 Ems« 3 [� [ �f o c e d/ 6k% u �\ \ _ r t EE 2 �E VI CD J /in 2 \ �_ b \ \ U3 020 In22 k / / \ \ \ / ƒ / @ 5 = E§ !® � 7 - E 3 � » _ ƒ 04 / u 0 2 ¥© w 5 a _2 © / / ice§ {/ / \ / \� 5 \ f \ \ / \ : LU \ | ! f { §g w . kn CD k\ Lno Ek § a =3 §E CL _ = _ Q g \\ - [ rn C:$- /3u \G3@ 7 25 %d ® �§$/ e= �� �keo n/93 7 U3 ` : , LU \ w . kn k\ Lno (/ 6§ rn \\ 7 %d ® �= E e= n/93 \k / cn ƒS \ _§ - @� -.,t2 / \ ea «� \ /2 /. (2 -Um r - H IGGJ [Hal) Peal-{ OIWPU,Sa IeAOI 0 0 c O `q M s U N 0 co LO O OD N G r- O lt7 G O O O O `� O O lt7 N O `4' N CO S CD E N y N 3 N N U U N N C77 N O C'7 O CD r N 0 fi O �j O (5-" O_ 6) d 0 0 63 %) 1t N 1 f G CV r•- CV CV (''] r- _� O O N M O O O O O C O N 0 0 0 0 0 0 0 �� D M MEN ME ME ME GN T NINE � MINNIE r IGGJ [Hal) Peal-{ OIWPU,Sa IeAOI 0 0 c O `q M s U N 0 co LO O OD N G r- O lt7 G O O O O `� O O lt7 N O `4' N CO S CD E N y N 3 N N U U N N C77 N O C'7 O CD r N 0 fi O �j O (5-" O_ 6) d 0 0 63 %) 1t N 1 f G CV r•- CV CV (''] r- _� O O N M O O O O O C O N 0 0 0 0 0 0 0 �� D I GN T � rr�n UJ r (D y d) N C : o NO 9 L o 1O D _Nll W ❑U co UU O �D cm Lli U J d a ISI C o •�U o —0 E O J;D y N O 0 UN �"'. O i JQi •V Ov v L:l Q c U o � �0Urt4 ` ' G Q v J O n U t- 4) F� 1p 3 0o LL N , n 'v o oo _a iD L > D N `c ~ O 3 L.L. 'a :5 p S J O J 3 0 -0 �� f l U Z -7F3T QI . S 3 O zo� _ N � S _ o o= Ql a' j 0 2 � U E G S LU �- 11-05-1998 03:09PM FROM E 0 CHURH INC TO 19709258275 P.03 Property Address Legal Description LOT 2, GENTRY LOT SPLIT AS AMENDED Property Owner: Name RICHER Address Phone Contractor: Name NORRI$ AND ASSOCIAT29 Address P.O. BOX 5759 SNOWMASS VZLLNGE, CO Phone _ - -- Saturation and Swelling: * Smeared surfaces 'emoved:XYeS _No * Sand or gravel added: -Yes XNo * Date and time presoak water added: 08-27-98 10:00 A.M. AND 5:00 P.M. * Amount of water added (gallons) 5 GALLONS/HOLE * Date and time perc test started: 08-28-98 8:00 A.M, * water remaining in hole after 2 hrs Hole 1 THRU 13: _Yes _XNo Percolation Rate Measurement * Percolation Rate (MPI) Hole 1 20 Hole 8 13 Hole 2 20 Hole 9 20 Hole 3 20 Hole 10_2Q_ Hole 4 - 20 Hole 1124_ Hole 5 4Q Hole 12 13 Hole 6 20 Hole 13 13 Hole 7 20 Average 23 Average 17 Excavating Contractor: Name Address Phone Groundwater: Profile 2 * Encountered at NONE FT. * Estimated depth to maximum seasonal water table if not encountered in profile:>101 * Ts area believed to be subject to fluctuations which could result in a seasonal water table within 8' of surface? Yes Y Slope in Absorption Area: * Profile 2 - to the E Bedrock: Profile 2 * Encountered @ z foot. * Estimated depth if not encountered in profile: * Type of Bedrock: SHALE * Is bedrock believed to permeable? X Yes No I certify that the above information is correct and complete to the best of my knowledge and that all tests were performed in accordance with the provisions of Pitkin County Individual 5ewaaQ Dig,} sa v em RegUlatzon, Section 5-1 through 5-7 and under the direct supervision of the reviewing Registered Engineer. Edward 0. Church, P.E. Job No. 10006 Fig. 5 Percolation Test Result Form Hole No. Hole Depth (in.) Length of Interval (min.) Water Depth at Start of Interval (min.) Water Depth at End of Interval (min.) Drop in Water Level (min.) Percolation Rate (min./in.) 1 18 30 8.00 11.00 3.00 10 11.00 12.00 1.00 10 12.00 12.50 0.50 10 12.50 13.00 0.50 20 2 19 30 8.50 11.50 3.00 10 11.50 12.75 1.25 10 12.75 13.25 0.50 10 13.25 13.75 0.50 20 3 16 30 7.00 10.00 3.00 10 10.00 10.75 0.75 10 10.75 11.25 0.50 10 11.25 11.75 0.50 20 4 30 30 17.00 23.75 6.75 10 23.75 25.00 1.25 10 25.00 25.75 0.75 10 25.75 26.25 0.50 20 5 15.5 30 8.00 10.25 2.25 10 10.25 11.00 0.75 10 11.00 11.25 0.25 10 11.25 11.50 0.25 40 6 24 30 14.25 18.00 3.75 10 18.00 19.00 1.00 10 19.00 19.50 0.50 10 19.50 20.00 0.50 20 7 18 30 7.00 10.75 3.75 10 10.75 11.50 0.75 10 11.50 12.00 0.50 10 12.00 12.50 0.50 20 JOB NO. 10006 FIG. 6 51 Percolation Test Result Form Hole No. Hole Depth (in.) Length of Interval (min.) Water Depth at Start of Interval (min.) Water Depth at End of Interval (min.) Drop in Water Level (min.) Percolation Rate (min./in.) 8 18 30 5.00 12.00 7.00 10 12.00 13.00 1.00 10 13.00 13.75 0.75 10 13.75 14.50 0.75 13 9 13 30 4.75 9.00 4.25 10 9.00 10.00 1.00 10 10.00 10.50 0.50 10 10.50 11.00 0.50 20 10 13 30 3.25 5.50 2.25 10 5.50 6.50 1.00 10 6.50 7.00 0.50 10 7.00 7.50 0.50 20 11 16 30 6.25 10.25 4.00 10 10.25 11.25 1.00 10 11.25 12.00 0.75 10 12.00 12.50 0.50 20 12 11 30 3.00 5.50 2.50 10 5.50 6.25 0.75 10 6.25 6.50 0.25 10 6.50 7.25 0.75 13 13 19 30 6.50 12.00 5.50 10 12.00 13.25 1.25 10 13.25 13.75 0.50 10 13.75 14.50 0.75 13 1JOB NO. 10006 FIG. 7 Profile Hole Log PROFLE-1 PROFILE-2 RESIDUAL SHALE BEDROCK. DRY TO MOIST. 1 FIRM. TAN TO GREY 1 2 2 WEATHERED SHALE BEDROCK. FRACTURED. 3 MOIST. HARD. GREY 3 Lu 4 4 Lu 1 o 5 5 m Lu o 6 -n m m 7 9 9 10 10 NOTES: I. INDICATES BACKHOE REFUSAL. A SMALL RUBBER TIRE BACKHOE SIMILAR TO A CASE 580 WAS USED 2. NO GROUND WATER ENCOUNTERED ONE DAY AFTER THE EXCAVATION OF THE PROFILE PITS. riNO. 10006 FIG. 11-05-1998 03:10PM FROM E 0 CHURH INC TO 19709258275 P.05 ASPEN/PTiI4N ENVIRONMENTAL HEALTH DEPARTMENT ISDS DESIGN CALCULATIONS Owner's Nacre : P # Parcel 11) # ���:ae 75 d, 100 d, or 130 d 130 House Size (sq. ft) M ' ( gP gP gT' ) Number of Bedrooms in Main House Number of Offices, Libraries, Studies, Similar -sized Dooms in Main House ; Number of Bedrooms in Detached Caretaker unit Number of Offices, Studies, Similar -sized Rooms in Caretaker Unit (If the caretaker unit is ATTACHED, treat as if part of main house.) Average Daily Waste Flow _780 State Review Required? no $�P,�. Pere Rate � � ; ,'� ci Design Flow (Q) = # potential bedrooms X 2 people/bedroom X gpd X 2.75 Q= 1365 Absorptior Area (A- Q/5 X SQRT) A 1126 sq. fL of absorption area required X73 infiltrator units without reduction A .imaxn 30% reduction is allowed for use aE deep gravel or graveness chxatbe red system, only if the lot size and soil conditions are optimal. IF a reduction is being props secs, de9esibe why lot size and soil conditions are optimal: A = 788 sqA with reduction 51 infiltrator units with reduction Type of system: nAbsorption trenches []Absorption bed Q Gravelless chambers ODry well (]Seepage Pit floor "OVER -EXCAVATED° PRESSURE DISTRIBUTED Minimum tank capacity 1706 gallons SETBACK FROM WELT, # of feet � 229 SETBACK FROM POND, STREAM OR IRRIGATION DITCH # of feet= 79 SETBACK FROM DRY GULCH # of feet 54 FINAL INSPECTION BY: DATE: TOTAL P.05 r_ J 11-05-1998 03:10PM rROM E 0 CHURH INC TO 19709258275 P.04 Engineer's Submittal for Septic Permit in Pitkin County Owner's Last Name: RICHER Location: GENTRY LOT SPLIT Summary of information regarding new septic system: Type of system being proposed "OVER -EXCAVATED" SAND FILTER PRESSURF. DI517RIBUTED C 1kMBER BEDS Other treatment processes being used NONE Does the system use any mechanical parts? (Prohibited unless there is no alternative)YFS If yes, explain why there are no alternatives PRESSURE DISTRIBUTION IS REQUIRED BECAUSE OF SHALLOW BEDROCK AND "OVER -EXCAVATED" SAND FILTER DESIGN Does the system require any maintenance other than routine pumping? YES If yes, who will do the maintenance? CARETAKER OR SERVICE PERSON WILL NEED TO CLEAN (110SE QMBIOTUBE FILTER IN PUMP VAUU17 Are any reductions being proposed? YES If yes, what makes -the !ot and soil conditiorm Qpk%al? STANDARD CHAMBER REDUCTION WITH USE OF CHAMBERS IS REQUESTED Which of the following are on the site or within setbacks? Closest distance of septic system to each feature 100 year floodplain well(s) >129' Q irrigation ditches .NSA Q streams NLA [J ponds > -Icf other features What was the profile hole depth?5,^5' What is the depth to groundwater? >9' What is the depth to bedrock? 1' What assumptions, if any, were made in system sizing and design? (Include any local, site- specific data, such as months without snow cover, ratio of evaporation to absorption, etc. that are relevant.} SAND FILTER APPLICATION RATE OF 0.45 GALLONS PER DAY PER DUARE FEET If there are any variations from normal design, please explain how they can be demonstrated to improve treatment and protect water quality. NONE SCHMUES. November 22, 1989 Mr. Jim Curtis Curtis & Associates 117 South Monarch Aspen, CO 81611 -- 3Grand Avenue. Suiie 2-E .. .v MEYER INC�� C`. Wwood Springs, ColoraUo 81601 ,11 '. (3031 945-1004 (303) 925-6501 'i>f - �+7T" Fax (303) 945-5948 CONSULTING ENGINEERS 8 SURVEYORS EXHIBIT 8 RE: Engineering Analysis Lanae Pronert-y Test !X7ell Dear Jim: At your request, given below is my engineering analysis of the Wildcat Ridge test well. The test well was completed on August 18, 1989, to a depth of 480 feet with a static water level of 225 feet. Pump tests and chemical analysis have been performed. The following appendices are attached hereto for reference. a. Well location map b. Pump test data, Attachment A (3 pages) c. Chemical analysis tests, Attachment B (1 page) d. Well completion report, Attachment C (1 page) e. Well permits, Attachment n (4 pages) Water Quantity Based on the test pumping, the well produces 10 to 12 gallons per minute (gpn) of water. This is a high quantity of water and will be ample for residential domestic use. The above well would be ample to service a cluster development of a principal residence, a caretaker unit, arra limited irrigation of less than one acre of lawn and garden irrigation. We have estimated average day use at 2.9 q_pm and peak day use at 8.7 gpm. Water Quality The chemical results for the well fall within the Primary Drinking Water Standards established by the State. The well is high in total dissolved solids, represented in large part by sodium and sulfates. Cn the other hand, the hardness is average or "not hard". I would expect the water to have a slightly salty taste. I would not anticipate the need for water softening since this process will not decrease the total amount of dissolved solids in the water. The iron content was below dectectable limits; the manganese content is detectable but below acceptable limits. Therefore, I would not recom- mend treatment for either iron or manganese removal_ at this time. November 22, 1989 Mr. Jim Curtis Page two Please note that the presence of iron was detected during the test pumping. This may have been from residual iron introduced during the well drilling process, or it is possible there is some dissolved iron that precipitated from the sample during transport of the water sample to the testing laboratory. Quite often, dissolved iron content will vary after a well is put into production. The possible need for iron removal should be re-evaluated after water use has occurred on a regular basis. Engineering Design and Fire Protection The specific engineering design of the well water supply system will depend on the actual development program for the property. Generally, the supply system will consist of a 2-3 horsepower submersible pump within the well; an intermediate holding tank or cistern, with esti- mated size of up to 2000 gallons, with pumping directly to pressure tanks and treating the water for hardness and iron before the water enters the plumbing system of the house. The specific fire protection plan will depend on the actual development layout for the property. Typical guidelines include installation of an in-house sprinkler and alarm system; using the aforementioned water holding cistern with standpipe and hose connection for storage for outside protection and immediate response' use; and installing fire extinguishers. Well Permits Two exempted 35 acres or greater well permits have been issued for the property. These permits can service two developnezt clusters for the property. Please feel free to give me a call on any questions, or if you wish me to provide more detailed information. Sincerely, SCHMUESER CORDON MEYER, INC. W. Gordpn, P.E. ident J EWG­1�22 cc: Wells Lange Peter Leslie ,- J14 4"W wiwwr Ray" PM" 7t- 2- j od Awv. 7 OM I j110A0— Ior t --TEST VVELL LOCATION 'Ulna 2—f it, lu A, py-leo �7 lit cov�j nit 00 p.. \AAIAC.Ae k;j 141 2 �441;� 01 7"T can VNwej, �y . �0- Subdivision Plan Lange Property North or co Mm ---------- O Ln C U') (3 of 1= 1C � Lr) C"i cli IM '••-i 42; �_-, M.- .,"�",::-c•.;• i�::"i•',r^ ` , R" pT 52 t (1 of 3) WELL TEST REPORT Name Address /-51.Z Gzavn AVE% �e _1ta)00&. SP s. 'n. 14�-roc. t Date 4 o Telephone '?a� Well Log Depth QE'O Water Level Casing Siie Draw Down Pump Setting G 00 Production Test Pump �P 1 �� �'_{x )�� 5 i) iTt�� /S ,art �n -- F nW ADL DRAWDOWN RECOVERY TIME I MIN. I LEVEL GPM TIME I MIN.. I LEVEL %:30 0 I ZZ3 = ''I 1':304)11 0 i zsz=- 7:31 1 I --zir i 6' �1 ":31 i t - 4 4 8 21'_q" i a I�ZQ'2 10 -" 10 1z( '—Q" 12 =?�' 12 1747L11 I is =z 4 ! is ! z• 2 Ji 20 z-34' -j" 1 20 I ZQ/' /'• 30 2-3T,-4 " 1 30 1 Z /_ 40 -z )_ " 1 40 1 Z / ,* 50 Z371— 1,! I 50 12-? 7=/ " 60 Z3` LO" 60 12 i%' 6„ 90 I ! 90 I Z3 6— -7 120 zoo_/o :30 18042 L 2 = 240 2 .. 3�0 0 =44L 11 z4 s . 4 f / 0 :Z4,7' I /779 :c62 "? NZ: ss RA /as i z A4 �Ae4 .0 ® ,I' - wt, / 6 ar I i I I 1 AT'T 3 JOHN C. KEPHART & CO. GRANO MUM LABORPORE 435 NORTH AVENUE • PHONE 242-7618 • ANALYTICAL REPORT Received from: Schmueser- Gordon Meyer-. Inc. Glenwood Springs, CO GRAND JUNCTION, COLORADO 81501 Lab Dir.: Brian S. Bauer- 5745 water - Customer No. Laboratory N0. Sample e/'1/89 11/8/89 Date Received Date Reported Sample Snowmass Limits Well -For drinking Arsenic (As) 0.00() ma/ 1 �?. 5 ma/1 Darium (Ha) i,.07 mg/ l 1. mg/1 Cadmium(Cd) o.00( -)i, ma/1 0.oI mq/l Chromium(Cr) mg/l 0. u5 mg/l Fluoride(F) 0.'4 mg/1 .4 ma/1 Lead (Pb) it. QC,ciIng/ 1 ci, i15 mg/1 Mercury (Hg) C)()(-)oo mq/ 1 0. iii,'? mg/ i Nitrate(N) 0.11 mg/l 11?.o mg/l Selenium(Se) A.00() ma/l 0.cii ma/l Silver(AQ)i,.t.it_,lii, ma/l i,. C,5 mg/1 Color(Co/Pt unit) o 5 pH i;. 0 - Conduct ivityid?5 degrees C 1'OO umhos/cm - SodiLim(Na) -8 ma/l mail CaIciLim (Ca) 14 ma/1 - Magnesi.um(Mg) 11 mq/l 1�5 mg/1 Potassium (K) ma/ l - Chloride(Cl) mq/I mg /1 Su I -f:at e (SO4) 177 mg/1 225, mg/1 Phenol. rAlkal inity (CaCO3) ci mg/1 - Total Alkalinity(CaCO3) dh<, ma/1 - bicarbonate(HCO') 557 lnq/1 - Carbonate(CO3) i,.(► ma Dissolved Solids 957 ma/1 500 mg/l Hardness ( CaCO3) mq/1 21= ,C, ma/1 Turbi d i t y (NTU) .1 .-► Boron (P) 107 ma/1 - Copper (Cu) 0.01i, mg i 1 1.0 ma/1 Ictal Irc+n(Fc) 1>.00 mail . ma/l Manaanese (Mn) 0.015 ma/ l 6. 05 ma/1 Molybdenum (Mo) 0. iilji, Mg/1 - Ammonia(N) 1.45 mg/l - Phosphate(P) 0.05 mq/1 - Zinc (Zn) 0.0 1 ma/1. 5.Q ma/1 Lab Dir.: Brian S. Bauer- JLORADO DIVISION OF WATER RE-,)URCES XTHIFE RM MUST BE SUBMITTED 1313 Sherman Street - Room 8.18 60 DAYS OF COMPLETION Denver, Colorado 80203 WORK DESCRIBEDHERE. ON. TYPE OR PRINT IN BLACK WELL COMPLETION AND PUMP INSTALLATION REPORT INK. mil-1 5297 PERMIT NUMBER WELL OWNER w,31 T nrrz;, 1r ',: of the ',�/ l: of Sec. ADDRESS r.�In 9?9hrn-^aPr 1512 r;rAnd AVA- C11?nvawd 10 _!3, R.96 6 P DATE COMPLETED $ - 19 9 HOLE DIAMETER WELL LOG — 9 in. from 0 to 25 ft. Water C....., I T.. T..-..,.. 4 r-l-, -4 RA,t.,;�1 1 nr —I;- in. from 15 _ to 4P') ft. in. from to ft. DRILLING METHOD Air `tOt•3rY CASING RECORD: Plain Casing Size ? & kind St'-'''-? from to �o Size & kind PVC from 20 to 4 '0 Size & kind from to Perforated Casing Size & kind PVC from 420 to 480 Size & kind from to Size & kind from to GROUTING RECORD Material Camant Intervals 10-25 Placement Method Gravit GRAVEL PACK: Size Interval TEST DATA Date Tested S l 19 _ Static Water Level Prior to Test 190 Type of Test Pump Air Co:ap=es!3or Length of Test 2 'lours Sustained Yield (Metered) 15+ Final Pumping Water Level :)tot31 G- -- o g¢ ewIc SMITH wtSogATES O wm e[V[HTH OT NT SOLS_MK COLORADO 6806802 (303) 442-6846868, 442-47468 PAX POPE RESIDENCE LOT 2, GENTRY LOT SPLIT WILDCAT RIDGE SNOWMASS, COLORADO w O lil ©I NQ ERIC g OCIATES 0YO1910 SEVENTH STREET R. COLORADO 603 E9O04-6468. 448-4746 FAX ♦ POPE RESIDENCE LOT 2, GENTRY LOT SPLIT WILD CAT RIDGE SNOWMASS, COLORADO +il���;E� II