HomeMy WebLinkAboutpitkin.eh.272909202002 (2001)Permit # 01006 Pitkin County Environmental Health Department Permit for an Individual Sewage Disposal System 0405 Castle Ck Rd, Aspen, Colorado 81611 Phone 970-920-5070 / FAX 970-920-5077 Parcel ID # 2729-092-02-002 Type of permit New( ) Repair() Addition to House( X ) Name of Owner Edie Engstrom Street Address -454W Property legal description Size of lot 14.56 00 Lot 8 Wild Rose Ranch Total square footage of the house 2144 Water source Private spring shared # of bedrooms in house 3 # of offices, lofts & similar sized rooms in house -- Caretaker unit -- # of bedrooms in caretaker unit Designed for what # rooms (list) Designed by Total square footage of the caretaker unit -- # of offices, lofts & similar sized rooms in caretaker unit -- THREE (3) Jerome Gamba & Associates Permit information Mailing Address PO Box 1458 Glenwood Springs CO 81602 Perc rate 32 Profile hole depth 8 ft Depth to groundwater or bedrock + 8 ft Septic tank capacity 1,313 gal minimum Absorption area 1188 - 30% infiltrator reduction = 831 sq ft Comments Septic permit approved per compliance with the engineer design and specifications stamped 1/15/01. Any changes must be approved by this department and the design engineer prior to them being made. Minimum horizontal distances between components of the system and physical features shall conform to the Pitkin County ISDS regulations. The existing system must be abandoned properly. The design is for a 1500 gallon two-compartment concrete tank, distribution box with a baffle, and an infiltrator bed 6 units wide by 9 units long, 54 units total. This department does not endorse any brand of products. The engineer must do a final inspection of the installation and submit an as -built letter to this department. This department must also be called for an inspection with a minimum of 48 hours advanced notice. Permit approved by: az, Date:te Plans and specifications of the p osed individual sewage disposal system have been reviewed and are considered satisfactory. Permission is hereby granted to the owner or the agent to perform the work indicated in accordance with thtkin County ISDS Regulation in effect at the time of issue. This permit becomes invalid 6 months from the date that the permit was issued unless system construction has commenced or an extension has been approved in writing by the Department. As -built drawings must be included with this permit before the final approval will be issued. Installer: SitI DMIC-) 0 Final Inspection Approval V)r �i��,�� n� �' n Ar�c�('Y�` i � � ASPER ;'KIN ENVIRONMENTAL HEALTH D eRTMENT APPLICA; ION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM 130 S. Galena St., Aspen Colorado 81611 Phone 970-920-5070/Fax 970-920-5074 Name of OWNER Owner's Mailing Address Business Phone: 4) 06.). 4 Home Phone: sei pt Primary Contact Person (all communication regarding this permit will go through this person) Name n S o Company Contact Mailing Address :57a ev,. JL_ Business Phone : Cell Phone: Fax Parcel ID # (available from assessor's office at 920-5160 or at www.aspen.com/assessor/) �a Street address of property 6 iqi-o �, e Legal Description: Lot ,Block Filing Size of lot: -` acres. Type of proposed structure: 1900 ,Subdivision 4/ .AClic Size of bldg. envelope: Total square feet of house 14*,-4�* # of bedrooms in house # of offices, lofts & sim lar sized rooms in house Caretaker Unit: Attached ( ) Detached ( ) Total area(sq. ft.) of caretaker unit # of bedrooms in caretaker unit # of offices, lofts and similar size rooms of caretaker unit Permit is for: New Home ( ) Repair due to failure ( ) Remodel/Addition Emergency use ( ; Water: Private well ( ) Spring `') Stream ( ) Community/Public Water System ( ) If community system: Name of system The fee for a ISDS application is $330 for a permit that takes 6 hours or less for the department to approve. If approval takes lonaer than 6 hours, a rate of $55 per hour will he charged The maximum fee is $1000. The basic fee of $330 is due at the time of application. The remainder, if any, will be due in two stages: first, at the time of issuance of the ISDS permit; second, before final approval of the ISDS permit. Application for an individual sewage disposal system is hereby submitted. I hereby certify that the above information is true and accurate and that I have provided true and accurate information on locations of all existing and proposed wells, contour intervals, buildings, property lines, ditches, slopes, waterlines, springs, suction or irrigation lines, drinking water cisterns, drain tiles, irrigation ditches, lakes, water courses, streams, floodplains, dry gulches, and existing septic systems. I hereby certify that any such features not shown on attached site map are not present. Issuance of the permit does not imply the approval of any other permit required for construction pursuant to Pitkin County codes. No construction may be undertaken until all approvals and permits have been obtained. The Aspen/Pitkin Environmental Health Department, Pitkin County and employees of these agencies will be held harmless should the individual sewage disposal system fail or malfunction. The permit to construct is issued on information submitted by the applicant or his/her representatives. The owner assumesfulTre, risibility in case of failure of the system. Signature of applicant Date g pp Received by _ )� 1� . Receipt # 1�0- Date G:\eh\isds\isdsapp\iscisapp.doc ora � 0 0 To: T.Carter Page Gamba Associates From: Carla Block, PCEHD Fax: 970 945 1410 Pages: 2 (Including cover sheet) Phone: Date: 5/18/04 Re: Engstrom ISDS Permit cc: Please find following the final ISDS Permit for the Engstrom Residence at Lot 8, Wild Rose Ranch. If you have any questions about this permit please don't hesitate to call me. Thank you, Carla May 18, 2004 RE: ISDS Permit Final Approval Edie Engstrom 0311 Bobcat Lane Redstone, CO 81623 Dear Edie, Please find enclosed a copy of your ISDS Permit from the Pitkin County Environmental Health Department which has received final approval. If you have any other queries, please feel free to contact myself or Carla Block, Environmental Health Specialist, at any time. Kind Regards, Erena Miller Administrative Assistant Pitkin County Environmental Health Department Enclosure (1) August 26, 2002 Edie Engstrom 0311 Bobcat Lane Redstone, CO 81623 RE: Engstrom Residence Parcel # 2729-092-02-002 Dear Mr. Engstrom: This letter is to advise you that the Individual Sewage Disposal System (ISDS) permit for the above stated residence/property have expired. The permit applied for became invalid 6 months from the date that the permit was issued. Information concerning projects that are continuing to be constructed must be brought to the attention of this office no later than September 16, 2002 to have their permits extended. Other wise, the permit will be considered expired. If this project has been abandoned, please notify this office. Thank you, in advance for your help and co-operation in this matter. Sincerely, Beth Seeman Pitkin County Environmental Health cc: Jerome Gamba & Associates G A M B A & ASSOCIATES CONSULTING ENGINEERS & LAND SURVEYORS W -GA M R A E NG I NEE R I NG.COM PHONE: 970/945-2550 FAX: 970/94S-1410 113 NINTH STREET, SUITE 214 P.O. Box 1458 GLENWOOD SPRINGS, COLORADO 81602-14S8 Sunday, November 23, 2003 Nancy MacKenzie Pitkin County Environmental Health Department 0405 Castle Creek Road, Suite 10 Aspen, CO 81611 RE: Final inspection of Engstrom Residence, 800 Dorias Drive, Tract B, Wild Rose Ranch, Redstone, Colorado 81623 Parcel ID # 2729-092-02-002 Dear Nancy: We have carried out final inspections on October 3`d and 21" to confirm that everything is in place. Accordingly, we are transmitting the attached two -sheet set of As -Built plans for the ISDS systems at this residence, bearing my stamp and seal and the date of November 23, 2003. This letter is intended to serve as our certification that all components and systems were installed in substantial compliance with our design plans, as modified in the field, Pitkin County Environmental Health Regulations, and the manufacturers specifications. The only exceptions we are aware of is that the disturbed areas have not been reseeded and mulched, and at the time of our last visit, the Smartfilter® alarm had not been fully wired in. Neither of these elements will adversely affect the operation of the system in the short term, though both need to be completed in order to a) protect the surface from erosion and b) to help the owners keep the filter clean. Assuming that you have no comments or requests for revisions or modifications to these As -Built plans, please send a copy of the final permit to both this office, and to Edie Engstrom, 800 Dorias Drive, Wild Rose Ranch, Redstone, Colorado 81623. Please call if you have any questions. Sincerely, Gamba & Associates, In �rTa_g ,17735161 Enclosures: As -Built Plans 00197 Engstrom cc: Edie Engstrom; File 02369 Engstrom - Letter of final inspection - To Pitkin County Environmental Health Sunday, November 23, 2003 Page 1 of 1 Macy -15-03 07:35P Gamba,. & Assoc V M KA ! D " & ASSOCIATES CONSULTING ENGINEERS 6 LAND SURVEYORS PHONE* 970/945-2550 FAX: 970/945-141 O 113 NIINTN STREET. SUITE 214 P.Ot Box 1459 GLENWOOD SPRINGS, COLORADO 8 1 602-7 456 Thursday, May 15, 2003 Edie Engstrom Engstrom ISDS, 00197 0311 Bobcat Lane Redstone, CO 81623 by FAX to 963-2670 970 945 1410 P-02 RF; Fxicting to Lk Conditions, filter and addiiloital vault recommendations. Dear Fdie- Regarding the existing septic tank, as I said over the phone recently, the condition of the septic tank appears to be excellent. At the time of my inspection on Tuesday, Play 13�', the tank had been recently pumped. There was approximately an inch of liquid in both compartments. I saw no sign of any leaks or significant dam -age. Both the inlet and outlet pipes are 4 -inch ductile iron pipe. This pipe is generally very strong, but can corrode with exposure to wastes and chelmicals. There was evidence of minor corrosion in the outlet pipe, I could not see the inlet pipe where it entered the septic tank, but the outside appeared to be in good condition. Regardless, I recom�tmend replacing these pipes with PVC pipes meeting the ASTM standard specification D-3034, which would be SDR 35 PVC. I also did not see any cleanout on the sewer line from the building to the septic tan -k_; I strongly recommend that a cleanout be installed. There are four access and inspection openings in the tank. The first is a rectangular opening approximately 1 -foot wide by 1.35 -feet long (all dimensions are to the outside of the opetungs, the openings are narrower at their bottom to keep the lids from dropping into the tanks at the ituet end. The second is a 1.65 -foot diameter round opening roughly in the middle of the first compartment. The third is another rectangular opening similar to the inlet opening in size, located directly over the separation wall between the first and second compartments, and providing access to both the separation wall and the concrete baffle, which adjoins it. The fourth opening is another rectangular opening, smaller than the first two, with a width of 0.65 -feet and a length of 1 -foot, over the outlet end, and the concrete box baffle at that location. The inlet end of the tank has a concrete baffle extending across the full width of the tank, and extending 1.96 -feet below the inside top of the tank. There is a small gap at the top of the inlet baffle, the width of the access cover (0.8 -feet), and approximately three -inches high. The baffle between the first and second compartments extends 2.5 -feet below the inside top of the tank. The baffle is formed of a concrete box with dimensions approximately the same as the middle access hatch. As on the inlet baffle, there is a small gap at the top of the intermediate baffle approximately three -inches high. Engstrom ISDS Thursday, May 15, 2003 Page 1 of 3 May -15-03 O7:36P Gamba & Assoc 970 945 1410 P_O3 The outlet baffle is a roughly square box with (plan view) dimensions of the access hatch, and extending 2.5 -feet below the inside top of the tank. The cover over the outlet access/inspection hatch needs to be replaced, as it has a cracked corner. The broken corner will lead to dirt and debris entering the second compartment of the septic tank. The tank sits relatively level. The outlet is approximately four -inches lower than the inlet, which is satisfactory. The volume of the first compartment is approximately 795 gallons, and that of the second is approximately 331 gallons, so the ratio between these is satisfactory. The relatively minor "corrosion" of the concrete around the outlet baffle is not evident anywhere else that I could see. I do not believe that the minor spalling visible there will have any significant effect on the performance of the system, though it may lead to an earlier failure of the tank if not dealt with soon. I recommend that when the work is being done on the system, a competent concrete contractor should be contacted to give some recommendations on how to prevent any further spalling of the concrete in that location, which should keep the tank in good shape for some time to come. There are a number of materials on the market, which will seal off the area of damage and help to prevent, or at least slow, the progress of spalling. I made measurements of the actual inside dimensions of the tank, and the real internal volume available for use is approximately 1,126 gallons. This is 124 gallons less than the stated and printed volume of the tank (1,250 gallons). I suspect that the stated volume does not include the volume lost to the internal separation wall or to the concrete baffles. The minimum volume required according to the permit is 1,313 gallons, so an additional volume of 187 gallons (minimum) is required to comply with Pitkin County requirements. In addition, Pitkin County requires the installation of a filter on the outlet of the tank. There are some filters available, which can be inserted into the end of the tank, inside the square concrete outlet baffle, which might work with the existing tank, but I do not recommend their use in this case. In order to increase the available volume of the septic tank, I recommend that you purchase the smallest available supplemental tank that will satisfy the requirement of having at least 187 gallons of internal volume, and a means of placing the required filter. There are a number of inlet basins, meter pits, sand traps, etc. that will satisfy these requirements, but the simplest which I have found would be a 36 -inch diameter, one -Piece Section Sand Trap, 66 -inches h„gh as manufactured by Copeland Concrete. You are not going to be using this as a sand trap, clearly, but a supplemental tank for the additional volume that you need, and as a place to site the effluent filter. The "sand trap” would be placed at the outlet end of the tank, as close as you could reasonably locate it. This item will provide an additional 220 gallons of volume. You will also need a 24. -inch concrete cover for the Sand Trap, have Copeland tell you which cover fits best. The outlet filter that I recommend using is the Zabel model Ai00- 8X18-VCF with a SmartFilter Alarm. This Zabel filter has a flow capacity of 1,200 gallons per day, and the SmartFilter Alarm will warn you if the filter Engstrom ISDS Thursday, May 15, 2003 Page 2 of 3 May -15-03 07:37P Gamba & Assoc 970 945 1410 P-04 becomes plugged. As a matter of policy, Gamba & Associates, Inc. (G&A) does not recommend using effluent filters without an alarm system. I am attaching "cut -sheets" from Copeland Concrete (2 sheets) for the sand trap, and Zabel Filter and SmartFilter Alarm (3 sheets) for the filter which I am recommending. Circled items are what I am recommending be purchased. I am not requiring that these manufacturers be used, there are certainly other manufacturers out there, and some doubtless provide equivalent items. I have not made any significant effort to research other available sources for the tank or the filter, these manufacturers are the ones we most commonly use, and are the most familiar to us. Please feel free to contact other companies and manufacturers if you wish. The parameters for the volume of the supplemental tank (187 gallons minimum) and the filter (1,050 gallons/day minimum and 1/16 -inch filtration) should be strictly adhered to. The most current price lists in my possession for these items provide the following costs. Actual costs may be different. Ory. Item Description Item Cost 1 Copeland 36" Dia. x 66" High with 36" cover (18A) $546.00 1 Copeland 24" Dia. concrete lid (15) $40.00 1 Copeland Delivery to Redstone $183.00 1 Zabel AIOO-8xl8-VCF Filter $112.00 1 Zabel SmartFilter Alarm 75.00 Total: $956.00 Copeland Concrete is at 28803 U.S. Highway 6 & 24, Rifle, Colorado 81650, and their phone is: (970) 625-1112; FAX is (970) 625-1110. Zabel filters and the alarm are available from the factory at (800) 221-5742, or online at www.zabelzone.com. If you have any questions, please call. Sincerely, Gamba &,ssociaj, Inc. E/ / J�I%Alr PabeA ,. 35161 cc Nancy MacKenzie, Pitkin County Environmental Health, by FAX to 920-5077; File: 00197 H \00197-EnXs6rom1Ft11er and vault recommendadonsAm F r?g&,rom %SDS Thursday, h!a, 1 S, 2003 Page 3 of 3 May -15-03 07:37P Gamba & Assoc 970 945 1410 P.05 IPELAAN CeacrETE 28803 U.S. Hwy. 6 & 24 PM. rn Q,ccn � (3031625.1112 v V Tu v� �% �c v a c,"Cir FTs- &0_V1—"r- - 36, D_V—c- ?6" ONE FJ ECF SECTION SAND TRAP Fi�,C F—XICIT-Wk- =` rl �� � �ie rfUW RPinfnrced with 645 10_10 or heavier wire. Sanri. trap can be brought up t�rae rich coverheavy dut-y riser. See cast iron for 5" Knockouts n�o A 24" ^ • lt� �ve4,. -` T. L1 4 1 CO X l 57" inlet I j 14 I 1 [Vol I T 6 ,. - 3 Drawin rfl Ro , 8 A � �ng ramie ��..� 't I• " I I A c7AC* 4 5 outlet 4 1 CO X l 57" inlet I j 14 I 1 [Vol I T 6 ,. - 3 Drawin rfl Ro , 8 A � �ng ramie ��..� May -15-03 07:38P Gamba & Assoc 970 945 1410 P_06 CC Co���w�e 28603 U.S, Hwy. 6 & 24 ��Ecoul L COITFLE S" FPQII 20" to 60" Rifle, CO 81650 11 - 4jjC-J - WI b i V �-1 rF or 2011 casing AIS covers Z..__ 2891 r e.M. orced V ' v 2'13_-91 For 24.1 211 1—� - 6 _ • n ., . �--f casing 1 f Covers with or without For 36" casing 24" opening 4.21+ V 2411 -3 - : las Ic V [A• t7 � � ry ~ L5 ! • 4 .r ° LA 4 P p cJ' a • v �` I r� Ci r-- 1% For 4811 casing K A11 J� .f For 6U" 68" 2411 T)rRw ngs t 3 l � � 15R 1 AW �+ 14Dr 091 �._ � i casing dP > a aVr� 6" to 0 n ,n A • � 1V 1 2411 i At k Drnwing Page 15 May -15-03 07:38P Gamba & Assoc 970 945 1410 3 r 121fM_q 2M Al 00"" 8" garicc Ioitraticio P.07 • 'Versa -Case accepts 4" or 6" SCH 40 outlet pipe and is available with Supplemental By -Pass Protection • ideal for residential application where increased TSS and BOD -44 --- reductions are desired 0 • Available in 3 lengths to handle waste flows from 1200gpd to 2400gpd • New and improved disc dam design decreases turbulence and promotes settling of solids • Reducer/Adapter built into every case • unique outlet hub will accept 4" or 6" SCH 40 pipe • Extension handle included with every filter -Rr r♦] Rasiden,i.0 Applivatiun cctt.8cd Wblanuard 46 A"100 w $; - Handle Parts Included Uniquely designed Filter +11�'�$9f av-�wrr viSC reuu€eS iliibUiance +x.., and promotes sloughing! A �B t i A - Zabel 112° Handle gON B =1/2" Schedule 40 pipe 3" ionq ! 'o\so 2 M.* Y Filter tt" Contin e' 0�er enfal L,, 7 A1OO-8x26-WC www.zaaeizone.com � _. � ��►�`� �221 1 -S742 A100 -808 -VC 8"x18" Cartridge & Versa -Case 110.95 92.00 1 82,n0 81.00 00.00 A100 -8x26 -VC 8"x26" Cartridge & Versa-Case114.95 II I 96.00 86,00 I + 85.00 84.00 A100 -8x32 -VC 8"x32" Cartridge se I 119.95 100.00 90.00 i 89.00 88.00 A iv0-8xi8 Cartridge &Versa -Case Filtered 00 1 83.00 81. ,!-8x26--VCF8"x26" Cartridge & Versa- ase 1-iltered 115.95 97.00 8 85.00 A100 -8x32 -!ECF ! 8"x32" Cartridge & Versa -Case Filtered 120.95 101.00 ! 91.00 90.00 89.00 i .. A101 8X18 8"x18" Replacement Cartridge 1 85.95 69.00 42.00 A101 -8x26 ` 8"x26"FepiacementCartridge 89.95 73.00 ! 46.00 A101 -8x32 I 8"x32" Replacement Cartridge 93.95 77.000 ` 50.00 A100 -8x18 -VC -FP A100 -8x18 -VC & 22" Casin AsseFmFuly , 261.95 192.00 A100-8x18-VCF-FP A100-8x18-Vf_F & 72" Basin Assembly ! 262.95 1 193.00 Add $75.00 to the price of any filter or filter Mackay tp add th€ Smar"Filter Alarm, V May -15-03 07:38P Gamba & Assoc 970 945 1410 Zabel' At 00'" 8" Series Effluent Filter Product Specification 11 MTMIM: • Residential and light commercial applications up to 24uu Uru • 50-90°10 reduction in TSS within b months of installation • 20-459% reduction in BODS within 6 months of instaiiation • Disc dam plates reduce turbulence and promote s.ioughing • Case, central support and handle constructed of PVC • Lid and filter discs constructed of polyethylene • Outlet hub accepts 4" or 6" 5CH 40 (see graphic below) • 4" reducer built into case • Filter support may be achieved by extending a 4' support pipe from the reducer to the bottom of the tank. IN } NIVAJ Il PVC il"eknfrtbil Support System Now includes Stainless Steel i I reinforcement rod for extra strength and dura~ to IPatent Pending / l i / ill Filters are now available with Supplementary By - Pass protection �-_ Patent Pending 13.525' 5.51'1 � - - tas• t P -I I Outlet Hub options 4• $CH a0 1 i _ ouiet pipe 6"S040 outiet pipe 4.645` A100 -8x26 -MC •--- 9.6440" A100-8:18-yC F -- - — 9.9W --►. —4.545-Y !� Ac 12155 4' SCh 440 AI0"jl 2 -'VC A100 -8x18 VC{ /1(16" �� I 492 in' 1.356 in' T8 A100 -8x26 -VC 1116" 1Boo 738 int i 2.034 in' 117 A100 -802 -VC 1(16" 2400 I 984 int 2,712 in 1S6 Filtered Versa -Case`"' models ,VCF) have same specs as ;VC) models. G Product;S; covered by one or more J.S. an&ortnternational patents. Other U.S. and international patents may be pendinq Call Direct to ORDER 1-800-221-$742 • Or Order Online.- wwvv.zabe-lzntne.COm 45 -15-03 07:39P Gamba & Assoc 970 945 1410 • Alerts you when the tank and filter are ready to be serviced • Designed exclusively for Zabeh Filters • Easy to install and remove. • Each SmartFilter Alarm comes with SmartFilter switch and alarm • SmartFilter switches are also available without the alarm • Purchase the SmartFilter Alarm when you buy filters for greater savings SmartFilter Alarm L Ai ARRIED FILTER SYSTEM ♦1L 1 uY11... ;. -#orgy ,: • ; Outdoor Alarm 8 Vii. SmartFilter Switch 1�- SrnastFilter Switch ilfl� All Zabeh Filter NAcc -T-SP i et- 'Alarms I-wo-.221-�!�' 14-2 54 0 side two Parcel D, Address: Person Spoken TO Comments Action to be Taken WWI I . WNM r, ... __ - �M. ,. K - i i7► A � side two *.ir JEROME GAMBA & ASSOCIATES, INC. CONSULTING ENGINEERS & LAND SURVEYORS 113 9TH STREET, SUITE 214 P.O. BOX 1458 GLENWOOD SPRINGS, COLORADO 81602-1458 PHONE: (970) 945.2550 FAX: (970) 945.1410 November 2, 2000 Eddie Engstrom 0311 Bobcat Lane Redstone, CO 81623 I)ear E K]ie: The following is the soil information for your proposed Residence addition, located on Tract B of the Wild Rose Ranch, Pitkin, Colorado. A soil profile 8'— 9" total depth, was excavated within the proposed absorption area. The excavation revealed no ground water to the depth of the profile hole. Soil Classification of the profile hole is as follows: 0" to 4" Aggregate Road Base 4" to 8' Red colored silty sand and gravel w/ scattered cobbles. Jerome Gamba & Associates, Inc. performed percolation testing in the area of the proposed septic system. Three percolation test holes were excavated using a backhoe and hand shovel for the final 12" test pit. The Test holes were presoaked the night before the testing was performed. The results of the percolation testing are presented on the percolation results sheet. These results indicate a design percolation rate of 32 min/in. Page 1 of 1 G:\00197-Engstrom\SOI LS.doc ASPEN/P KIN ENVIRONMENTAL HEALTH DEPARTMENT ISDS DESIGN CALCULATION Owner's Name.:r,,._ �.. Parcel ID # Imo. House Size (sq. ft.) 2400 (75 gpd, 100 gpd, or 130 gpd) 100 Number of Bedrooms in Main House Number of Offices, Libraries, Studies, Similar -sized Rooms in Main House Number of Bedrooms in Detached Caretaker unit Number of Offices, Studies, Similar -sized Rooms in Caretaker Unit (If the caretaker unit is ATTACHED, treat as if part of main house.) Average Daily Waste Flow: 600 State Review Required?: no Avg. Perc Rate (t) =777V7 Design Flow (Q) = # potential bedrooms X 2 people/bedroom X gpd X 1.75 Q = 1050 Absorption Area = A = x 5 / A = 1187.94 sq. ft. of absorption area required V 77 infiltrator units without reduction A maximum 30% reduction is allowed for use of deep gravel or gravelless chambered system, only if the lot size and soil conditions are optimal. If a reduction is being proposed, describe why lot size and soil conditions are optimal: A = 831.56 sq.ft. with reduction 54 infiltrator units with reduction # of feet = 104 SETBACK FROM POND, STREAM OR IRRIGATION DITCH # of feet = 54 SETBACK FROM DRY GULCH # of feet = 29 FINAL INSPECTION BY: Page 1 of 2 DATE: Zwart Residence ISDS C Percolation Testing Results This report has been prepared according to generally accepted engineering practices for the design of Individual Septic Disposal Systems within Pitkin County. The conclusions and recommendations submitted in this report are based upon data obtained from our field investigations of the proposed site. There is some possibility that the nature and extent of the subsurface soil across the site may not have been discovered during our investigations and may require additional field work. If further excavation reveals conditions different form those described, our office should be notified of these findings as soon as possible. If you have any further questions regarding this soil investigation please call us. Sincerely, Jerome Gamba & Associates, Inc. Chris Strouse, Design Engineer 4 l Robert W. Pennington, P.E. Page 2 of 2 JEROME GAMBA & ASSOCIATES, INC. CONSULTING ENGINEERS & LAND SURVEYORS cPERC SHEET ERCOLATION TEST RESULTS FORM Engstrom Property HOLE No. DEPTH OF TEST HOLE TIME TME INTERVAL MEASURE MENT DROP in WATER LEVEL PERCOLATION RATE REMARKS (in) (min.) (min) (inches) (inches) (min/in) #I 35 1:22 27 3/4 1:35 0:13 28 5/8 0.875 15 1:45 0:10 28 3/4 0.125 80 2:05 0:20 29 1/4 0.500 40 2:25 0:20 29 7/8 0.625 32 2:45 0:20 30 1/4 0.375 53 3:05 0:20 30 5/8 0.375 53 #2 40 1:25 16 3/4 1:36 0:11 18 1.250 9 1:46 0:10 19 1.000 10 2:06 0:20 20 1/2 1.500 13 2:26 0:20 22 1/4 1.750 11 2:46 0:20 24 1.750 11 _ 3:06 0:20 25 3/4 1.750 11 # 3 44 1:27 32 3/4 1:37 0:10 33 3/8 1:47 0:10 33 3/4 0.375 27 2:07 0:20 34 3/8 0.625 32 2:27 0:20 35 0.625 32 _ 2:47 0:20 35 3/4 0.750 27 3:07 0:20 36 1/2 0.750 27 Page 1 ,_ _ - .. . a. ,; -, . �, , _. s .. _ ya-. .f .. __ s ; s � .mow` ,. ` � � , .. � �.. .,-..n ... �.�.+"�.. "�,. � , .. a ,. .. - . �: _ - , ,. ,: � �. a �..,« ,� 00 -- =- NATURAL GROUND / BACK FILL WITH EXCAVATED MATERIAL STANDARD INFILTRATOR LEACHING CHAMBERS. 2' min. / 6' max. (SEE INFILTRATOR INSTALLATION INSTRUCTIONS) COVER (TOP) FROM - DISTRIBUTION BOX \4" SDR 35 PVC DISTRIBUTION PIPE CROSS SECTION OF INFILTRATOR BED NOT TO SCALE BACK FILL WITH EXCAVATED MATERIAL (SEE INFILTRATOR INSTALLATION INSTRUCTIONS) 6' max. COVER (TOP) \ G \ r 4" SDR 35 SEWER PIPE FOUR (4) INSPECTION PORTS, SET AT NATURAL GRADE CORNERS OF BED: 4" PVC RISER W/ PLASTIC VALVE BOX COVER, 4" NOTCH / CUT INTO BOTTOM OF PIPE. 7 � � 2' min. COVER (TOP) - (min. tYP ) STANDARD AS—BUILT BED ARRANGEMENT CONSISTS OF SIX 6) PARALLEL INFILTRATOR UNITS ROWS OF SEVEN (7) UNITS EACH (42 UNITS), PLUS TWO (2) END SECTION OF INFILTRATOR BED PARALLEL ROWS OF SIX (6) UNITS EACH (12 UNITS), FOR A TOTAL OF 54 UNITS, PER DESIGN CALCULATIONS. NOT TO SCALE 20" 0 CONCRETE LID RECTANGULAR, TAPERED INSPECTION PORTS (typ.)(typ.) 4" PVC SEWER PIPE 0.32, MINIMUM SLOPE = yy EXISTING 4" DIA. CAST IRON INLET PIPE FROM CLEANOUT & CONCRETE INLET HOUSE — (SIDE BAFFLE ENTRY TO TANK) CONCRETE J �� CONCRETE BOX BAFFLEOUTLET BOX SECONDARY BAFFLE CHAMBER — PRIMARY CHAMBER — USEABLE USEABLE VOLUME VOLUME = 106.4 cu.ft. = 795.6 gal. = 44.27 cu.ft. _ 331.1 gal. CROSS SECTION OF EXISTING CONCRETE SEPTIC TANK — CAPACITY: 1,250 gal. (NOMINAL) — 1,126.7 gal. (ACTUAL) NOT TO SCALE TO FILTER CHAMBER FROM SEPTIC TANK 4.55' FOUR (4) INSPECTION PORTS, SET AT CORNERS OF BED: 4" PVC RISER W/ PLASTIC VALVE BOX COVER, 4" NOTCH CUT INTO BOTTOM OF PIPE (typ.) EXTEND FILTER HANDLE TO JUST 0.35' UNDER ACCESS LID TO DISTRIBUTION BOX 3.00'0 VOLUME = 29.69 cu.fL = 222.06 gal. ZABEL A100 8X18 VCF EFFLUENT FILTER - '0TH 4.20' SMARTFILTER ALARM CROSS SECTION OF FILTER CHAMBER — VOLUME 222 gal. NOT TO SCALE �/\� 35 SEWER P\PE CNPMSER / \80"(10N 805 1P Mg N pES \l) MON\SOR �., \NF\V3RP5�R10 PV-UN\Tp 2p,5 z) 0 SO• ENGSTROM RESIDENCE 3 BEDROOMS, > 2,000 sq.ft. FLOOR AREA \aae) EX\SS\NOt P ,K (\e { 2n P S /Ou'C `,e{t IGVAoc) g.6g, (5" mina EXISTING HOUSE / = 27.00, v O I(20• min_) / 41.31' (25 min.) G v r 14.97' min.) I .,a�•93'45 J 3.72' (10 in v v 1" WATER SERVICE /QOP P� ��/ / I V / =, Olt Q0/ O / EXISTING �\ HOUSE / / �` E _ 000000, / SVC ^f\ \ n ^ ?ryMAD �1 30 0 30 60 90 GRAPHIC SCALE IN FEET 1 INgi - 30 FEET APPROXIMATE LOCATION ACCESS ROAD PROPERTY LINE \ &1k \ DyE r 1 1101101031 AS—BUILT PLANS AND DETAILS mr I top top REV r.ir, DATE REVISI❑N MADE DV CHKD I DV APPD DV PROPERTY LINE AS -BUILT SITE PLAN SCALE, DATE: January 5, 2001 DRAWN BY; CHKD BY, APPD BY: PFT CWS RWP SHEET 1 of 2 PLAN NO. 00197\AS—BUILT TOTAL UNITS) SDR PVC 6 (typ-) (Z% Smin. 35 tyP.) 8 HOLE CONCRETE DISTRIBUTION BOX W/ BAFFLE. IRRIGATION BOX FOR ACCESS 11 PLUMBING DETAIL NOT TO SCALE CALCULATION FOR LEACH FIELD SIZE PIPES EN INFILTRATOR END PLATES (typ.) 45' PVC ELBOWS (Typ.) 4" SDR 35 SEWER PIPE FROM NEW FILTER CHAMBER SYSTEM WAS DESIGNED AND INSTALLED TO SERVE A SINGLE FAMILY PRIVATE RESIDENCE WITH THREE (3) BEDROOMS. ACCORDING TO PITKIN BUILDING AND SANITATION DEPARTMENT, I.S.D.S. REGULATIONS, TO CALCULATE EFFLUENT FLOW, ASSUME TWO PERSONS PER BEDROOM USING AN AVERAGE DAILY EFFLUENT FLOW OF 100 GALLONS PER PERSON PER DAY FOR RESIDENCE OVER 2000 SQUARE FEET OF LIVING AREA. (3 bedroom) x (2 persons per bedroom) = 6 people AVERAGE DAILY EFFLUENT FLOW = (6 people) X (100 gpd/person) — 600 gpd MAXIMUM DAILY EFFLUENT FLOW = 1.75 x AVERAGE DAILY FLOW (1.75) x 600 gpd = 1,050 gpd MINIMUM REQUIRED SEPTIC TANK SIZE, FOR 30 hours (1.25 days) DETENTION = MAXIMUM DAILY FLOW x 1.25 days = 1,050 gpd x 1.25 days = 1,313 gallons. EXISTING TANK HAD A NOMINAL VOLUME OF 1,250 gal., BUT PHYSICAL MEASUREMENTS INDICATED AN ACTUAL USEABLE VOLUME OF 1,126.7 gal. WITH APPROVAL OF PITKIN COUNTY, THE EXISTING TANK WAS SUPPLEMENTED BY THE ADDITION OF A 3 ft. DIA. ONE—PIECE FILTER CHAMBER, WITH THE DIMENSIONS SHOWN IN THE DETAILS. THIS PROVIDED AN ADDITIONAL VOLUME OF 222 gal., GIVING A TOTAL OF 1,348.7 gal., AND A SITE TO LOCATE THE EFFLUENT FILTER. THE ABSORPTION AREA (A) FOR A NORMAL GRAVEL TYPE LEACH FIELD IS CALCULATED USING THE FOLLOWING FORMULA: A = QV�t WHERE: Q = MAXIMUM DAILY SEWAGE FLOW = 1,050 gpd —5— t = PERCOLATION RATE = 32 min/in. THEREFORE: A = (1,050) x 32 = 1,187.93 sq. ft 5 According to the Pitkin County Environmental Department, for the design of a Leach Field incorporating grovelless chamber units (Infiltrator units) in a bed configuration, a reduction of the required absorption area can be a maximum of 30% of the above design area. For this design we will use a 30% reduction. THEREFORE, the required area for the Leach field is (0.7) x (1,187.93 s.f.) = 831 s.f. THEREFORE: The number of Infiltrator units required is = (831 s.f.)/(15.5 s.f./unit) = 54 units Bed configuration WAS DESIGNED as 6 rows wide by 9 units long, however, site restraints required a re—configuration of the bed. As—Built in the field, the bed consists of 6 rows of 7 units in length, (42 units) and 2 rows of 6 units in length, (12 units), for a total of 54 units. All Minimum Horizontal Setback Distances shall conform to Pitkin County, Individual Sewage Disposal regulations. All components of the septic system shall be installed according to the Pitkin County regulations, Colorado Department of Health and according to manufacturer specifications. See attached 0 & M Manual provided by Jerome Gambo & Associates, Inc. GENERAL SYSTEM MAINTENANCE NOTES: 1. No driving over or parking of vehicles on bed. 2. Maintain positive drainage away from the bed at all times. 3. Residence served by a Commumity Water System. 4. Boundary data provided by Lines in Space, Inc. Engstrom Residence 800 Dorla5 Drive, Tract B, Wild Rose Ranch Redstone, Colorado CONSUIUM ENGINEERS do LAND SURVEYORS POST OFFICE BOX 1458 113 NINTH STREET — SUITE 214 GLENWOOD SPRINGS, COLORADO 81602 (970) 945-2550 SHEET NO. PROJECT: 00197