HomeMy WebLinkAboutpitkin.eh.272920305046 (2014)D� ONSITE WASTEWATER TREATMENT SYSTEM (OWTS) EH/NR CONSTRUCTION PERMIT CO ' 76 Service Center Rd- Aspen, CO - 81611 Phone: 970.920.5070 Fax: 970.920.5374 Permit #: 0031.2014.powt Parcel ID #: 2729-203-05-046 Permit Issued: ❑NEW ®REPAIR ❑REMODEL/ADDITION ❑TANK ONLY ❑FIELD ONLY ❑AMENDMENT Owner(s): Alan Pil Property Address: Legal Description: 54 Elk Mountain Dr Lots 44, 45, 52, 53, and 54 Elk Mountain Subdivision Size of Lot: 1.318 (total) Acres Detached Accessory Unit: ❑YES ®NO Size of Building: 2965 Sq. Ft. Size of Accessory Unit: Sq. Ft. The system is designed for: 3 bedrooms. The workshop on the ground level is not a heated space and not considered a bedroom for the purposes of this permit.= Designed By: All Service Septic Phone #: 970-704-0484 Fax #: Project #: C1077 Dated: June 9, 2014 Mailing Address: Email Address: Perc Rate: 25 Mpi Profile Hole Depth: 8 ft Depth to Groundwater or Bedrock: Minimum Tank Capacity: 844 gallons Minimum Absorption Area: 851 ft2 (% Reductio Permit Conditions: Y 8 ft This OWTS Construction Permit is approved on the condition of compliance with the engineer design as submitted with the application and the specifications cited above. Changes must be approved by this Department and the engineer prior to construction. This permit is sized for 3 bedrooms. Sewage will flow via gravity to a new 1000 -gallon two-compartment concrete septic tank set outside of the driveway. An effluent filter will be installed in the second compartment. Effluent will flow via gravity to a distribution box and then to 5 split bed soil treatment beds with 18 chambers per bed. A total of 90 chambers will be installed. The soil treatment beds shall be a minimum of 100 feet to any well, 10 feet to the property line, and 50 feet to any surface water. Abandonment of the sprinkler system in the areas of the new soil treatment beds is recommended. This Permit must be kept on-site during installation. The engineer must do a final inspection of the installation and submit an "as -built" letter to this Department within 30 days of the final inspection, unless a longer period of time has been agreed upon, in writing. This Department must also be called for the final inspection with a minimum of 48 hours notice. Minimum horizontal distances between components of the system and physical features shall conform to the requirements of the Pitkin County OWTS Regulation. This Permit is conditioned upon the property owner(s) providing for regular inspection, cleaning, and maintenance of the system by qualified personnel, in accordance with the manufacturer's recommendations and the requirements of the Pitkin County OWTS Regulation. Issuance of this OWTS Construction Permit does not constitute a guarantee, warranty, or representation by the Department that the system will operate properly or will not fail. Issuance of this permit does not imply compliance with Pitkin County building and/or land use regulations, nor guarantee issuance of building and/or land use permits. THIS PERMIT IS EXPRESSLY CONDITIONED UPON COMPLIANCE WITH ALL REQUIREMENTS OF THE PITKIN COUNTY OWTS REGULATION, INCLUDING BUT NOT LIMITED TO THOSE CONDITIONS SPECIFIED ABOVE. Plans and specifications for the proposed OWTS have been reviewed and are considered satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated in accordance with the Pitkin County OWTS Regulation. This Permit will expire 1 year from the date of issuance unless construction on the system has commenced. An "as -built" drawing must be submitted and approved by EH before final approval of the system will be issued. Issued By: __j( ,-_ Date: 6/10/2014 Expires: 6/10/2015 Installer: License #: f (� aF Reactivation Authorized by: Final Approval Issued By.`'"Y' Date: New Expiration Date: JFee Ft1 i - ALL33 Four Wheel Drive Rd Carbondale, CO 81623 970-309.5259 11111 � , 1 July 6, 2014 Alan Pilkington anzacalan(a)aol.com Onsite Wastewater Treatment System (OWTS) Installation Observations 54 Elk Mountain Drive Pitkin County, Colorado OWTS Construction Permit Number 0031.2014.powt Alan, Project No. C1077 ALL SERVICE septic, LLC observed the installation of the onsite wastewater treatment system (OWTS) on June 19 and June 24, 2014 for the subject property. Nelly Construction installed the system and photo -documented the installation. The installation included a new 1000 -gallon, two-compartment concrete septic tank with an effluent filter on the outlet tee. This filter must be cleaned annually, or as needed. The septic tank was installed just outside of the driveway. The existing septic tank, located partially under the stairs, was filled with rock and abandoned in- place, along with the existing absorption area. Effluent gravity flows from the septic tank to a distribution box, accessible from grade, just below the landscape wall. The distribution box was filled with water and flow regulators were installed to assure equal distribution. Effluent gravity flows from the distribution box to five gravelless chamber beds. Four beds have 2 rows of 9 `Quick 4 Infiltrator® chambers and the fifth bed has 3 rows of 6 `Quick 4' chambers for a total of 90 chambers and 888 square feet of infiltrative area. The OWTS was generally installed according to specifications. This observation is not a guarantee of workmanship and/or parts and materials. ALL SERVICE septic, LLC should be notified if changes are made to the OWTS in the future. Any additional OWTS construction must be according to the county regulations. LIMITS: Observations are limited to components that are visible at the time of the inspection. The installer must have documented and demonstrated knowledge of the requirements and regulations of the county in which they are working. The quality of the installation is dependent of the expertise of the installer, soil type, and weather conditions. Please call with questions. L Sincerely, ALL SERVICE septic, LLC O -W, Ccs Carla Ostberg, MPH, REHS Reviewed Richard H r=� Line from house to new septic tank Abandonment of existing septic tank 1000 -gallon septic tank Inlet tee Outlet tee with effluent filter (need to replace rope with 3/" PVC handle extension) Rocks placed around septic tank to prevent traffic Line from tank going under landscape wall 4b <. . \ \ �� � \� �«� 2 OAS 40 G 0 . . , � ... � 0 .g . z.. . .y. 0 . . , � ... � 0 DESIGN 3 -BEDROOM RESIDENCE (75 GAL/PERSON/DAY x 2 PERSONS/BEDROOM x 3 BEDROOMS) AVERAGE DAILY FLOW = 450 GALLONS DESIGN FLOW= Q = 1.5 x 450 = 675 GALLONS TANK: 675 x 30 HOUR RETENTION TIME = 844 GALLONS USE 1000 -GALLON, TWO-COMPARTMENT TANK ABSORPTION AREA: PERCOLATION RATE = 25 MPI CALCULATED ABSORPTION AREA = Q/5 X SORT perc rate x 1.4 = 945 SF 10% REDUCTION, CHAMBER BED TOTAL REQUIRED AREA = 851 SQUARE FEET 5 GRAVELLESS CHAMBER BEDS FOUR WITH 2 ROWS OF 9'QUICK 4' CHAMBERS AND ONE WITH 3 ROWS OF 6'QUICK 4' CHAMBERS = 90 CHAMBERS CONCRETE SEPTIC TANK WITH EFFLUENT FILTER 4" DIA SDR -35 SEWER LINE WITH CLEANOUT (SLOPW 2% MIN TO TANK) PRO\ �\f 2 r\ RECORD DRAWING N 0' 10' 20' Scale: 1" = 20'-0" 'QUICK -4' CHAMBER BED. 4 BEDS WITH 2 ROWS OF 9 CHAMBERS/ 1 BED WITH 3 ROWS OF 6 = 90 CHAMBERS 'AT OF .' 33 Four Wheel Drive Road Pilkington Residence Date: 07/06/14 Carbondale, CO 81623 970.309.5259 S��� 54 Elk Mountain Drive Pitkin County, Colorado Designed B CBO 9 y: record SfflYICE Reviewed By: RHP Project Number: C1077 Drawn By: ANG Sheet 1 of 1 Do Your Part, Be SepticSmart: The Do's and Don'ts of Your Septic System Learn these simple steps to protect your home, health, environment and property value: �INIK'I septicsmart- LLS.E—,O..e .IProtectionAgcy Do: • Have your system inspected (in general) every three years by a licensed contractor and have the tank pumped, when necessary, generally every three to five years. Don't: • Pour cooking grease or oil down the sink or toilet. • Rinse coffee grounds into the sink. • Pour household chemicals down the sink or flush them. Don't: • Flush non -degradable products or chemicals, such as feminine hygiene products, condoms, dental floss, diapers, cigarette butts, cat litter, paper towels, pharmaceuticals. Don't: • Park or drive on your dra infield. The weight can damage the drain lines. • Plant trees or shrubs too close to your drainfield, roots can grow into your system and clog it. Do: • Eliminate or limit the use of a garbage disposal. • Properly dispose of coffee grounds & food. • Put grease in a container to harden before discarding in the trash. Cho: • Dispose of these items in the trash can! Do: • Consult a septic service professional to advise you of the proper distance for planting trees and shrubs, depending on your septic tank location. • Concentrate your water use by using your dishwasher, shower, washing machine, and toilet at the same time. All that extra water can really strain your septic system. • Stagger the use of water -generating appliances. This can be helpful especially if your system has not been pumped in a long time. • Become more water efficien by fixing plumbing leaks and consider installing bathroom and kitchen faucet aerators and water -efficient products. Milk 003j. 20t'f _ j6WT- ONSI fE WASTEWATER TREATMENT STEM (OWTS) dM EHCONSTRUCTION PERMIT APPLICATION CHECKLIST 76 Service Center Rd - Aspen, CO - 81611 Phone: 970.920.5070 Fax: 970.920.5374 A complete application package must be presented at the time of your pre -application conference for acceptance. To schedule a pre -application conference, please call 970-920-5070. PLEASE INITIAL EACH ITEM TO INDICATE COMPLETION Only one copy of each item is necessary. tr OWTS Construction Permit Application (completed) ,- Site Plan ❑ Please indicate the type of document to be submitted below. ❑ 11" X 17" and/or ❑ Electronic document emailed to ehnr(cDco.pitkin.co.us before the date of the pre -application conference All designs must be V to 20' in scale. ❑ Site plan must include locations of existing wells, buildings, property lines, ditches, water lines, springs, irrigation lines, drinking water cisterns, drain tiles, water bodies, wetlands, riparian areas, floodplains, dry gulches, and existing OWTSs. V Soil Testing Notification & Report (must be provided by a PE) This Department should be notified when soil tests are conducted. A 2"- 4" perforated PVC pipe should be placed in the soil profile hole for monitoring purposes. F ] Report must include percolation test results and the soil profile evaluation. V Building Floor Plans ❑ 11" X 17, or submitted electronically to ehnr anco.pitkin.co.us before the date of the pre -application conference. Land Use Approvals & Other Relevant Permits & Approvals ❑ Recorded Site Plan that designates approved envelope(s) for development. Ifftth�epaoq�tSyiAs�rrgitifnomttti>3sregp�rreant, plts�eea�<C�DummtlfiSYL>Iirr�rltFRterm$rc�srr»il:ehntta�o;pitfdncso�us �ttt,�rflimatt6�noffttt�exempitom. ❑ 24" X 36" and 11" X 17", or electronic document emailed to ehnr(cDco.pitkin.co.us before the date of the pre -application conference [] Copies of all land use approvals, as well as all other documentation relevant to the siting of the OWTS(s) and any other development on the property (e.g., Resolutions, Administrative Decisions, recorded easements). Comments from EH/NR regarding Land Use review referrals can be accessed by opening http //www aspenpitkin com/pdfs/depts/7/landuse odf and clicking the blue link in the "Referrals" column. Referral comments more than 2 years old may need to be requested from the County Planning Department. Construction Management Plan ❑ Required & Obtained ❑ Not Required Requirements: http.-Ilwww.aspenpitkin.com/Pdfsldeptsl7/CMP Manual-pForms: http//www aspenpitkin com/depts/7/bldpdiv cfm Proof of Adequate Water Supply Legal water supply must be demonstrated in accordance with Colorado water law and meet the requirements of the Pitkin County Land Use Code. l�/vl �'-�0, >� e� e �a u� i y r n �� le , rcw Private systems: Proof generally includes a well driller's report, well permit issued by the Colorado Division of Water Resources, final augmentation plan (if required), and a recent pumping report. Wells must be drilled before an application will be accepted. [-] Public systems: Proof generally includes a letter from the CWQCD - approved public water system confirming it has sufficient water to supply the development and it has agreed to do so. Initial Site Inspection All components of the OWTS, as well as the proposed buildings, water source, and other pertinent physical features must be clearly staked and labeled prior to the inspection. Inspection must be scheduled between May 1 st and Oct 31 st, unless otherwise approved by EH/NR. Applicable Fee OWTS Construction Permit: $1,023* ❑ Tank Only: $523* *There is an additional Administrative Fee of $175.00 for properties in the Town of Snowmass Village. Please Make Checks Payable To: Pitkin County Environmental Health & Natural Resources Department TO SUBMIT A BUILDING PERMIT APPLICATION PRIOR TO OBTAINING AN OWTS CONSTRUCTION PERMIT THE FAST TRACK WAIVER MUST BE SUBMITTED TO COMMUNITY DEVELOPMENT WITH YOUR BUILDING PERMIT APPLICATION. Please note that this waiver only allows for the submittal of the Building Permit Application. It does not allow for the issuance or approval of the Building Permit without OWTS Construction Permit approval from the EH Department. G:\OWTS March 8, 2008 NEW REGS Office - Admin\Forms OWTS Const Forms\OWTS Construction checklist.xls Updated:3/20 09 r-� OWTS DESIGN CALCULATIONS - for Pitkin Owner's Name Parcel ID # House Size (sq. ft.) (75 gpd or 100 gpd) Number of Bedrooms in Main House Number of Offices, Libraries, Studies, Similar -sized Rooms in Main House Number of Bedrooms in Detached Caretaker unit Number of Offices, Studies, Similar -sized Rooms in Caretaker Unit (if the caretaker unit is ATTACHED, treat as if part of main house.) Average Daily Waste Flow 450 State Review Required? no Perc Rate (T) Design Flow (Q) = # potential bedrooms X 2 people/bedroom X gpd X 1.5 Q= 675 Minimum tank capacity 844 gallons lw. Absorption Area (=Q/5 X SQRT perc rate)(1.4 loading factor) A = 945 sq. ft. of absorption area required Absorption Area (=Q/5 X SQRT perc rate) WITH SECONDARY TREATMENT (no loading factor) A= 675 sq. ft. of absorption area required Abs. Area w/ loading factor (B25) Trench Bed Quick4 Trench Quick4 Bed Pipe and Gravel (-10%) 851 no red. 945 86 96 Dosing (20%) 756 (20%) 756 77 77 Chambers (3976) 662 (-10%) 1" 67 86 Max Allowable fmkn 473 (-30%) 662 48 67 Secondary Treatment Abs Area w/ out loading factor (1328) Trench Bed Pipe and Gravel (-10%) 608 no red. 675 62 68 Dosing (-20%) 540 (-20%) 540 55 55 Chambers (-30%) 473 (-10%) 608 48 62 Max Allowable (-50%) 338 .(-30%) 473 34 48 100 SETBACK FROM WELL # of feet = 50 SETBACK FROM POND, STREAM OR IRRIGATION DITCH # of feet = 25 SETBACK FROM DRY GULCH # of feet = Pitkin County Mail - 54 Elk Mountain Drive Redstone $ rKI[fV OUxIr' 54 Elk Mountain Drive Redstone 1 message anzacalan@aol.com <anzacalan@aol.com> To: kurt.dahl@pitkincounty.com Cc: carla.ostberg@gmail.com, nellyconstruction@q.com Kurt, Page 1 of 1 Kurt Dahl <kurt.dahl@pitkincounty.com> Tue, Jun 10, 2014 at 10:32 AM I understand Carla Ostberg has sent you plans for the system improvement at 54 Elk Mountain Drive in the Elk Mountain Subdivision in Redstone, Pitkin County. This is to advise you we have decided to go with the 3 Bedroom option as contained in those plans. I assume you have all you need to move this forward, but please email or call me at 970 963 3027 if you have any questions. Thank you again for facilitating this matter. Alan Pilkington 54 Elk Mountain Drive Redstone, CO 81623 970 963 3027 https:Hmail.google.com/mail/u/0/?ui=2&ik=23 f7b56eb0&view=pt&search=inbox... 6/11/2014 C A ALL 33 Fair Wheel Drive Rd Carbondale, CO 81623 970-309-5259 June 9, 2014 Alan Pilkington anzacalankaol.com Project No. C1077 Subsurface Investigation and Onsite Wastewater Treatment System Design 2 -Bedroom Residence 54 Elk Mountain Drive Pitkin County, Colorado Alan, ALL SERVICE septic, LLC performed a subsurface investigation and completed an onsite wastewater treatment system (OWTS) design for the subject residence. The property is located outside of Redstone, in an area where OWTSs and wells are necessary. The legal description of the property is Lot 44 and 45 and Lot 52 thru 54, Elk Mountain Subdivision. SITE CONDITIONS A 2 -bedroom, single-family residence presently exists and is utilizing an existing OWTS. There is a desire to upgrade the existing OWTS. There is a private well located on the property. A minimum setback of 100 -feet must be maintained from the well to the absorption area and 50 -feet from the well to the septic tank. SUBSURFACE The subsurface was investigated on June 2, 2014 by digging one 8 -foot profile pit and running percolation test. Percolation tests were run in three holes, with results recorded in Table 1, Percolation Test and Soil Data Form, enclosed. Percolation rates ranged from 13 to 40 MPI, with the average percolation rate at 24 minutes per inch (MPI). The materials encountered in the profile pit consisted of light brown, slightly moist, granular, gravelly sand to a depth of 3 -feet, underlain by medium brown, 'moist, granular, gravelly sand with some large, angular cobbles to a maximum depth explored of 8.0 -feet. No bedrock or groundwater was encountered. The profile pit was excavated at high runoff. A percolation rate of 25 MPI will be used in this design. Page 4 OPERATION INFORMATION AND MAINTENANCE The property owner shall be responsible for the operation and maintenance of each OWTS servicing the property. The property owner is responsible for maintaining service contracts for manufactured units, alternating absorption systems, and any other components needing maintenance. Geo -fabrics or plastics should not be used over the absorption area. No heavy equipment, machinery, or materials should be placed on backfilled absorption area. Livestock should not graze on the absorption area. Plumbing fixtures should be checked to ensure that -no additional water is being discharged to OWTS. For example, a running toilet or leaky faucet can discharge hundreds of gallons of water a day and harm an absorption area. The homeowner should pump the septic tank every two years, or as needed gauged by measurement of solids in the tank. Garbage disposal use should be minimized, and non -biodegradable materials should not be placed into the OWTS. Grease should not be placed in household drains. Loading from a water softener should not be discharged into the OWTS. No hazardous wastes should be directed into the OWTS. Mechanical room drains should not discharge into the OWTS. The OWTS is engineered for domestic waste only. ADDITIONAL CONSTRUCTION NOTES If design includes a pump, air release valves and weep holes should be installed to allow pump lines to drain to minimize risk of freezing. Excavation equipment must not drive in excavation of the absorption area due to the potential to compact soil. Extensions should be placed on all septic tank components to allow access to them from existing grade. Backfill over absorption area must be uniform and granular with no material greater than minus 3 -inch. INSTALLATION OBSERVATIONS ALL SERVICE septic, LLC must view the OWTS during construction. The OWTS observation should be performed before backfill, after placement of OWTS components. Septic tanks, distribution devices, pumps, dosing siphons, and other plumbing, as applicable, must also be observed. ALL SERVICE septic, LLC should be notified 48 hours in advance to observe the installation. LIMITS: The design is based on information submitted. If soil conditions encountered are different from conditions described in report, ALL SERVICE septic, LLC should be notified. All OWTS construction must be according to the county regulations. Requirements not specified in this report must follow applicable county regulations. The installer should have documented and demonstrated knowledge of the requirements and regulations of the county in which they are working. 0 Please call with questions. Sincerely, ALL SERVICE septic, LLC Carla Ostberg, MPH, REHS Reviewed Page 5 • PITKIN COUNTY Percolation Test and Soils Data Form - TABLE 1 - PROJECT C1077 Performed by All Service Septic, LLC PROFILE PIT Date of Test: June 2, 2014 0-3 ft Sand, gravelly, slightly moist, granualar, light brown 3-8 ft ISand, gravel) with large angular cobbles, moist, granualar, medium brown Hole No. Hole Depth (in.) Interval (min.) Measurement at Start of Interval (in.) Measurement at Change (in.) End of Interval (in.) Percolation Rate (min./in.) MPI 1 29 10 27.00 27.25 0.25 10 27.25 27.75 0.25 10 27.75 28.00 0.25 10 28.00 28.25 FILL 0.50 10 26.25 26.50 0.25 10 26.50 27.00 0.50 10 27.00 27.25 0.25 40 2 35 10 31.25 31.00 0.75 31.00 31.50 0.50 31.50 32.00 0.50 32.00 32.50 0.50 32.50 33 FILL 0.50 30.50 31.00 0.50 31.00 31.50 0.50 20.00 3 30 3.5 FILL 2.50 3.5 FILL 1.00 3.00 3.75 FILL 1.00 2.50 3.25 FILL 0.75 2.00 2.75 0.75 2.75 3.25 0.75 3.25 4.00 0.75 13.00 AVERAGE = 24 MPI N 0' 15' 30' Scale: 1" = 30'-0" O OJ o 0 I OPTION 1 2 W2.0 OPTION 2 3 W3.0 I _ THE LOCATION OF EXISTING AND PROPOSED IMPROVEMENTS SHOWN ARE NOT THE RESULT OF A PROPERTY SURVEY. THE LOCATIONS ARE APPROXIMATE. IT IS THE HOMEOWNERS DUTY TO ENSURE ALL CONSTRUCTION AND IMPROVEMENTS LOCATIONS ARE ACCURATE. ALL SETBACK DISTANCES SHOULD BE CONFIRMED PRIOR TO EXCAVATION. 02 TE PLAN _ b DRAWINGS MUST BE USED IN CONJUNCTION WITH DESIGN LETTER DATED 6/09/14 33 Four Wheel Drive Road Pilkington Residence Date: 06/09/14 Carbondale, CO 81623 54 Elk Mountain Drive 970.309.5259 Designed By: CBO Reviewed By: RHP MIT[3 - Pitkin County, Colorado Project Number: C1077 Drawn By: ANG I Sheet 1 of 5 1:101 i< 2 -BEDROOM RESIDENCE (75 GAL/PERSON/DAY x 2 PERSONS/BEDROOM x 2 BEDROOMS) AVERAGE DAILY FLOW = 300 GALLONS DESIGN FLOW = Q = 1.5 x 300 = 450 GALLONS TANK: 450 x 30 HOUR RETENTION TIME = 563 GALLONS USE 1000 -GALLON, TWO-COMPARTMENT TANK ABSORPTION AREA: PERCOLATION RATE = 25 MPI CALCULATED ABSORPTION AREA = Q/5 X SORT pore rate x 1.4 = 630 SF 10% REDUCTION, CHAMBER BED TOTAL REQUIRED AREA = 567 SQUARE FEET 3 GRAVELLESS CHAMBER BEDS EACH WITH 2 ROWS OF 10'QUICK 4' CHAMBERS = 60 CHAMBERS 2 -BEDROOM RESIDENCE 1.� \ DRIVE N 0' 10' 20' Scale: 1"= 20'-0" Lm OBSERVATION PORTS AT OPPOSITE CORNERS OF EACH BED / PROFILE / HOLE D -BOX TO GRADE 1000 -GALLON, TWO-COMPARTMENT, CONCRETE SEPTIC TANK WITH EFFLUENT FILTER LINE OF NATIVE VEGETATION / /1 PROPOSED OWTS — OPTION 1 (1) 33 Four Wheel Drive Road Pilkington Residence Date: 06/09/14 Carbondale, CO 81623 R „ 970.309.5259 54 Elk Mountain Drive SCptl W2.0 A ,L^ . O SERVICE Pitkin County, Colorado Designed By: CBO VV Reviewed By: RHP Project Number: C1077 Drawn By: ANG Sheet 2 of 5 EXISTING DRAIN FIELD TO BE ABANDONED EXISTING TANK TO BE ABANDONED 4" DIA SDR -35 SEWER LINE WITH CLEANOUT ' (SLOPW 2% MIN TO TANK) pROpERry�INE QUICK -4' CHAMBER BED. J 3 BEDS WITH 2 ROWS OF _2 10 CHAMBERS = 60 J \ � CHAMBERS J Lm OBSERVATION PORTS AT OPPOSITE CORNERS OF EACH BED / PROFILE / HOLE D -BOX TO GRADE 1000 -GALLON, TWO-COMPARTMENT, CONCRETE SEPTIC TANK WITH EFFLUENT FILTER LINE OF NATIVE VEGETATION / /1 PROPOSED OWTS — OPTION 1 (1) 33 Four Wheel Drive Road Pilkington Residence Date: 06/09/14 Carbondale, CO 81623 R „ 970.309.5259 54 Elk Mountain Drive SCptl W2.0 A ,L^ . O SERVICE Pitkin County, Colorado Designed By: CBO VV Reviewed By: RHP Project Number: C1077 Drawn By: ANG Sheet 2 of 5 DESIGN 3 -BEDROOM RESIDENCE (75 GAL/PERSON/DAY x 2 PERSONS/BEDROOM x 3 BEDROOMS) AVERAGE DAILY FLOW = 450 GALLONS DESIGN FLOW = Q = 1.5 x 450 = 675 GALLONS TANK: 675 x 30 HOUR RETENTION TIME = 844 GALLONS USE 1000 -GALLON, TWO-COMPARTMENT TANK ABSORPTION AREA: PERCOLATION RATE = 25 MPI CALCULATED ABSORPTION AREA = Q/5 X SORT pert rate x 1.4 = 945 SF 10% REDUCTION, CHAMBER BED TOTAL REQUIRED AREA = 851 SQUARE FEET 5 GRAVELLESS CHAMBER BEDS FOUR WITH 2 ROWS OF 9'QUICK 4' CHAMBERS AND ONE WITH 3 ROWS OF 6'QUICK 4' CHAMBERS = 90 CHAMBERS 3 -BEDROOM RESIDENCE L� \ DRIVE N 0' 10' 20' Scale: 1" = 20'-0" D -BOX TO GRADE \ 1000 -GALLON, TWO-COMPARTMENT, ' CONCRETE SEPTIC TANK WITH EFFLUENT FILTER I E PROFILE HOLE OBSERVATION PORTS AT OPPOSITE CORNERS OF EACH BED 24 / / LINE OF NATIVE VEGETATION nPROPOSSEDD JOWTS — OPTION �2 33 Four Wheel Drive Road Pilkington Residence Date: 06/09/14 Carbondale, CO 81623 54 Elk Mountain Drive W3.0 /� 3. O 970.309.5259 Designed By: CBO V V SLIIII�L Pitkin County, Colorado Reviewed By: RHP Project Number: C1077 Drawn By: ANG Sheet 3 of 5 EXISTING DRAIN FIELD TO BE ABANDONED EXISTING TANK TO BE ABANDONED l 4" DIA SDR -35 SEWER LINE WITH CLEANOUT (SLOPW 2% MIN TO TANK) ' PRO PERTVCINE 'QUICK -4' CHAMBER BED. 4 BEDS WITH 2 ROWS OF J 9 CHAMBERS / 1 BED ? WITH 3 ROWS OF 6 = 90 J Q CHAMBERS D -BOX TO GRADE \ 1000 -GALLON, TWO-COMPARTMENT, ' CONCRETE SEPTIC TANK WITH EFFLUENT FILTER I E PROFILE HOLE OBSERVATION PORTS AT OPPOSITE CORNERS OF EACH BED 24 / / LINE OF NATIVE VEGETATION nPROPOSSEDD JOWTS — OPTION �2 33 Four Wheel Drive Road Pilkington Residence Date: 06/09/14 Carbondale, CO 81623 54 Elk Mountain Drive W3.0 /� 3. O 970.309.5259 Designed By: CBO V V SLIIII�L Pitkin County, Colorado Reviewed By: RHP Project Number: C1077 Drawn By: ANG Sheet 3 of 5 TYPICAL PLAN VIEW - N.T.S. 4" DIA PVC HEADERS 6' (1 % FALL TO LEVEL —A,,o MANIFOLD) DISTRIBUTION 6' MIN. BOX, WITH BAFFLE, BROUGHT TO GRADE- .. 4" DIA SDR -35 --f EFFLUENT INLET I INF REFER TO OPTION 1 OR 2 INFILTRATOR(R) QUICK4(TM) CUT SHEET (EF EC III LENGTH) _---PIPE D PLATE r1w NOTES: BED MAY BE ANGLED TO FIT TOPOGRAPHY AND TO MINIMIZE REMOVAL OF EXISTING VEGETATION. QUICK4(TM) END CAPS OBSERVATION/VENT PIPE (TYP.) INFILTRATOR(R) QUICK(TM) CHAMBERS, TX 4' CROSS SECTION OF TYPICAL CHAMBER -TRENCHES 4" SDR 35 PVC INFILTRATOR(R) OBSERVATION / VENT QUICK4(TM) PIPE WITH CAP BACKFILL CHAMBER, 3'X4' (MUST BE MINUS 3 -INCH MATERIAL) StopE 3.5' 1 =1 BED 'MIN EXTENT OF EXCAVATION --J LIMITATIONS -THESE PLANS MUST BE USED IN CONJUNCTION WITH LETTER AND SOILS DATA FORM BED MUST BE LEVEL. USE ONSITE SOILS TO BRING PROVIDED. THE DESIGN IS BASED UPON INFORMATION SUBMITTED. IF SOIL CONDITIONS ENCOUNTERED GRADE UP FOR LEVEL INSTALLATION. SOIL MUST BE ARE DIFFERENT FROM CONDITIONS DESCRIBED IN REPORT, ALL SERVICE SEPTIC L.L.C. SHOULD BE FREE OF COBBLES (MINUS 3 -INCH MATERIAL, AND NOTIFIED. ALL OWS CONSTRUCTION MUST BE ACCORDING TO COUNTY REGULATIONS. THE INSTALLER MUST BE COMPACTED WITH VIBRATORY SHOULD HAVE DEMONSTRATED KNOWLEDGE OF THE REQUIREMENTS AND REGULATIONS OF THE MACHINERY. BACKFILL SLOPE MUST EXTEND AT 3:1 COUNTY IN WHICH THEY ARE WORKING. THE COUNTY AND ALL SERVICE SEPTIC L.L.C.MUST VIEW ^CHAMBER DETAILS INSTALLATION. 0 I - 33 Four Wheel Drive Road Pilkington Residence Date: 06/09/14 �71R L Carbondale, CO 81623 54 Elk Mountain Drive SfRYICE 970.309.5259 Pitkin County, Colorado Designed By: CBO W4.0 Reviewed By: RHP Project Number. C1077 Drawn By: ANG Sheet 4 of 5 SLIP-ON PVC CAP DO NOT GLUE FINISHED GRADE— EFFLUENT LINE - 4" SCHEDULE 40 OR 4" SDR SEWER LINE - 35 P.V.C. 4"SCHEDULE 40 P.V.C. INSULATED COPPER TRACER WIRE MAY BE INSTALLED TO LOCATE LINE IN FUTURE n CLEANOUT DETAIL not m scut Septic Tank with the Addition of an Effluent Filter -1000 Gallon, 2 -Comp. Top of 1' trot Inlet Tee n TANK DETAIL N0T TO - Filter Cartridge Handle (field cut to desired height) Tank Adapter (cast or bolted) Vent Orifice Effluent Discharge BOX AND COVER BROUGHT TO GRADE CONCRETE LID Modulating Discharge Orifices FINSHED GRADE Vault Inlet Ports 0000 INLET OUTLETS Filter Cartridge BAFFLE DISTRIBUTION BOX Effluent Filter n D—BOX DETAIL I I 33 Four Wheel Drive Road Pilkington Residence Date: 06/09/14 L L Carbondale, CO 81623 54 Elk Mountain Drive SLII IIUL 970.309.5259 Pitkin County, Colorado Designed By: CBO 5 Reviewed By: RHP Project Number: C1077 Drawn By: ANG Sheet 5 of 5 /— 5 t�G-(c ltil DU N r N (� J L 'a(623 0 0 (,(c N► o c�J'J TA , N % �I U P-F�> s �-bNt I co Q�6z-731 u