Pitkin County Environmental N^alth Department
Jnsite Wastewater Treatment Systt.n (OWTS) USE PERMIT
Permit for Continued Use of an Existing OWTS
76 Service Center Road, Aspen, CO 81611
Phone: 970-920-5070 Fax: 970-920-5077
www.aspenpitkin.com/EHNR
Parcel ID #: 2729-292-01-092
OWTS Use Permit #: I 0034.2012.powu
Date Issued:
10/25/2012
Issued By:
Bryan Daugherty
Expiration Date:
10/25/13
Owner(s): I Bob and Lisa Dupre
Property Address:
1 100 Bear Creek Lane
Legal Description:
Other System Components
Licensed Inspector:
Carla Ostberg
Inspection Date(s):
10/18/12
SYSTEM INFORMATION
Components
Type
Capacity/Size
Primary Treatment Unit
Concrete 2 Compartment tank
1000 gallons
Secondary Treatment Unit
N/A
N/A
Absorption Area
Absorption bed
441 sq ftz
Other System Components
Dosing Tank w/ pump
1000 gallons
OWTS Use Status:
® In use at the time of the inspection. ❑Not in use at the time of the inspection.*
*If the OWTS was not in use at the time of the inspection, it is recommended that the system be re-evaluated when it is in use for a more accurate
evaluation of the system.
System Records:
Permit #: 03055 Date of Issuance: 9/23/03 Date of Final Approval: 10/28/03
# of Bedrooms or fixtures served by OWTS: This system was designed to serve 3 bedrooms
Operational Status: According to the inspector observations that system was working properly at the time of
inspection. The 1000 gallon, 2 compartment tank and 1000 gallon pump tank were watertight and in good condition.
The pump was working as well as the alarm. The field area did not show any signs of failure or surfacing effluent and no
liquid was present in the observation ports.
inspector Recommendations: N/A
Department Recommendations: N/A
Issuance of this OWTS Use Permit is based solely on the conditions observed and reported by the inspector to the Department on the date of the inspection(s) and
on Department records at the time of permitting. The issuance of this permit does not constitute a guarantee, warranty, or representation by the Department
that the system will operate properly or will not fail or that the system will not be subject to future enforcement action to correct non-compliant conditions.
Estimated capacity of the system has been listed on the permit and we recommend that you monitor and/or meter water use to prevent overuse and possible
failure.
Pitkin County Environmental Health Department
K I N' Onsite Wastewater Treatment System (OWTS)
USE PERMIT APPLICATION
OBU N T
76 Service Center Rd
Aspen, Co 81611
Website: www.aspenpitkin.com/ehnr/
Application for Continued Use of an Existing OWTS
Parcel ID# (available from the Pitkin County Assessor's Office /)
970.920-5160 or at www nitkinassessor.oro): G�
Purpose of Use Permit: V,mapERTY TRANSACTION [] REMODEL/ADDMON
Iam.nrry Address: A e A n- A -1. . A 1. 1--
e
of
of Bedroodroo
ms: \
Filing:
fixturesfuses:
Owners Mailing AddrQss: t
Home Phone: (A,J Businnesss P-hj„on)e.:3iV L CJ QISC]
.� r rnt un,ar:nn motef he orovided for the owner signing this application.
1d Systems
eLA-
Address:
is P— D
Zip:
Fax Number
A OrM
PLEASE READ BEFORE SIGNING:
I certify that the above information is complete and accurate and that I have provided complete and accurate Information in all of the documents
Included In my application package. I acknowledge that this department may revoke any permit t am issued if my application is found to contain any
Inaccurate, false, or misleading Information.
Date:
Date:
Please allow 3-5 business days for processing of Use Permits.
ORi0Fl=1GE US ;QN Y. st - .: -
E. Fee & Recelpt k. Date:
Received by EH Staff:
ate=-
!J
October 18, 2012
Bob Dupre
rgdupre(a)-gmail.com
CBO Inc.
33 Four Wheel Drive Road
Carbondale, CO 81623
cell) 970-309-5259 office) 970-704-0484
cbo2610@yahoo.com
Onsite Wastewater Treatment System (OWTS) Use Permit Inspection
100 Bear Creek Lane, Crystal River Park
Pitkin County, Colorado
I
As requested, CBO Inc. performed an Onsite Wastewater Treatment System (OWTS) Use
Permit inspection at 100 Bear Creek Lane, Redstone, CO.
The subject OWTS consists of a 1000 -gallon two-compartment septic tank followed by a
1000 -gallon single -compartment septic tank with a pump. Effluent is pumped to a
gravelless chamber bed with 5 rows of 6 Standard Infiltrator units (465 square feet). The
as -built drawing was provided by Pitkin County Environmental Health Department. (Parcel
ID # 2729-292-01-092)
The septic tanks appeared to be in good condition with all tees in place. The pump was
operational and the alarm was audible. The alarm alert is located in the lower level of the
house. The absorption area showed no signs of saturation and had no indication of failure.
Observation ports were present. This evaluation is not a guarantee of future system
performance. This inspection is good for one year.
This report should be submitted to the Pitkin County Environmental Health Department.
The following links are the required application and application checklist.
Application:
http://www.as )enpitkin com/Portals/0/docs/county/Com%20Dev/EHNR/OWTS%20Use%20
Permit%20Ap�plication.pdf
Application Checklist:
http://www.as )enpitkin com/Portals/0/docs/county/Com%20Dev/EHNR/OWTS%20Use%20
Perimt%20Application%20Checklist.pdf
0
Inlet tee, 1000 -gallon single compartment tank
Outlet of 1000 -gallon single compartment tank (in manhole vault)
Pump and floats in outlet side of 1000 -gallon tank
Owner's Name:
k 11111110
Onsite Wastewater Treatment Systems (OWTS) Use
Permit Inspection Form
Pitkin County Environmental Health Department
76 Service Center Rd, Aspen, CO 81611
Phone: 970-920-5070 Fax: 970-920-5374
Website: www.aspenpitkin.com/ehnr
Inspection form for continued use of an existing OWTS
Inspection Date:
Inspector's Name:
Business Name:
Pitkin County Systems Inspector License NU—MIJ4:
A copy of this Inspection report will be remitted to Pitkin County Environmental Heakh Degartment_by
the Licensed Systems Inspector within 60 days_ of the Lopection regardless of whether the systeEn
gasses or Lails.
QUESTIONS FOR PROPERTY OWNER PRIOR nOINSPECTION:
bthe home currently occupied? NO
|fNO, how long has the home been vacant? --
How many bedrooms are inthe home?
|fsecondary treatment isused, who isthe
maintenance provider? NJ A
RECORDS:
Y
` Were system records available from Pitkin County?
YES NO
If YES: be
--
Date of Final Approval: t0J-z9j0z)
of bedrooms permitted:
Was anas-built drawing available?
NO
VNO
|sthe as -built drawing accurate?
If NO: Complete odrawing qfthe system onlast page oythisformu5accurately ox
possible.
Any question marked FAIL will require correction before an OMITS Use permit is issued.
SITE CONDITIONS,
Proper grading, nnevidence oferosion? FAIL
Improper vegetative cover? YES
Evidence ofcompaction such asheavy machinery mrlivestock? e NO YES
Improper discharges such asstraight pipes? FAIL
Evidence ofhigh ground water? vs3
5nouvcover present? YES
u
""•"•
YES NO
Tank 1
PASS
Tank 2
Is the high water alarm working, both visible and audible?
Tank 3
Tank capacity
Tank material
0gallons
� -�
YES NO UNKNOWN
X &L
gallons
Goes the owner have a current maintenance contract for the unit?
gallons
# of compartments
Date of last pumping'j
Phone:
If there is no maintenance contract, a contract must be In place
prior to occupancy of the home. A
l
FAIL
Lids/risers in good condition
PASS
FAIL
aPAS
FAIL
PASS
FAIL
Risers to grade--
YES'
NO
YES
NO
YES
NO
Riser height
<
�
Riser condition/watertightness
00
n
Inlet sanitary T/baffle
PAS
FAIL
,PASS
FAIL
PASS
FAIL
sanitaryT/baffle
PAS
FAIL
PAS
FAIL
PASS
FAIL
t filter (if part of design)
on of tank material
as pumped for inspection
ist the pumping company
11evel
PAS
PASS'
YES
FAIL N/A
FAIL
NO
PASS
P
YES
FAI
N/A'
F
NO
PASS
PASS
YES
FAIL N/A
FAIL
NO
hen was the last pumping
vel (1st compartment)chesinches
level (1st compartment)
Ft)inchfesKiinche
ches
inches
vel (2nd compartment)ches
inches
Sludge level (2nd compartment)s
inches
Backflow (if pumped)
PASS
FAIL
PASS
FAIL
PASS
FAIL w
Midtank baffle
Watertightness
(PASS
PASS
FAIL N/A
FAIL
PASS
PASS
FAIL
N/A
FAIL
PASS
PASS
FAIL N/A
FAIL
PUMPS/DOSING SIPHONS:
Is a pump or dosing siphon present?
YES NO
If YES, is the pump/dosing siphon functioning properly?
PASS
FAIL
Does the pump/wiring/dosing siphon appear to be in good condition? PASS FAIL
Is the high water alarm working, both visible and audible?
< PASS FAIL
SECONDARY TREATMENT:
YES
Is a secondary treatment unit present?
YES NO UNKNOWN
If YES, does the unit appear to be in good working condition?
YES NO
Goes the owner have a current maintenance contract for the unit?
YES NO UNKNOWN
Maintenance Provider:
Phone:
If there is no maintenance contract, a contract must be In place
prior to occupancy of the home. A
copy of the contract must be submitted to Pitkin County Environmental Health Department.
ABSORBTION AREA:
Effluent surfacing?
Evidence of past surfacing?
Surface dampness?
Excessive odors?
Field location verified by observation ports or probing:
Liquid in observation port?
If YES, record depth:
Distribution Box or ADV part of original design?
If YES, is it accessible from grade?
Is it level and in good condition?
Page 2
UNKNOWN
PASS
FAIL
NO
YES
NO-'
YES
�NO
YES
Ports
Probing
NO
YES
inches
YES
YES
PASS
FAIL
Page 2
UNKNOWN
Any problems with the system that were not addressed in the inspection checklist?
Please list any recommendations for the continued use of the system:
Were any repairs done as a result of this inspection? NQ YES
If YES, please describe the repairs.
Tote 4est of my knowledge and training, the information collected in this inspection is accurate as of
20•
Licensed Systems Inspector Signature:
Additional Notes:
dearly 1pbel anypictures and attach them to this form.
Page 3
OF
l+itkin County Environmental Health Departmarlt
Pert for an Individual Sewage Disposal S. am
0405 Castle Creek Road, Suite 10, Aspen, Colorado 81611
Phone 970-920-50701 FAX 970-920-5077
Permit # 03055 Parcel iD # 2729-292-01-092
Type of permit New(x } Repair( } Addition/Remodel to House( }
Name of Owner Lisa Dupre'
Street Address TBA Bear Creek Lane
Property legal description Lots 46 & 47
Size of lot .5 acre
River Park
Total square footage of the house 1500 sq ft
Water source CommunitylPublic — Redstone Water District
# of bedrooms in house 3 # of offices, lofts & similar sized rooms in house
Caretaker unit Total square footage of the caretaker unit
# of bedrooms in caretaker unit # of offices, lofts & similar sized rooms in caretaker unit
Designed for what # rooms (list) 3 bedrooms
Permit information
Designed by High Country Engineering
Mailing Address 1517 Blake Avenue, Suite 101, Glenwood Springs CO 81602
Perc rate 16 Profile hole depth 8 ft Depth to groundwater or bedrock Greater than 8 ft
Minimum Septic tank capacity 984 gallons Minimum Absorption area 441 sq ft w/ 30% reduction
Comments
Septic permit approved per compliance with the engineer design and specifications dated August 7, 2003. This
design replaces permit #03011. Any changes must be approved by this department and the design engineer prior
to them being made.
Minimum horizontal distances between components of the system and physical features shall conform to the Pitkin
County ISDS regulations. There must be a minimum 25 -foot separation between the dry gulch and the field. Water
lines must be at least 10 feet from any tanks. Dry gulch that runs under driveway must be culverted at least 10 feet
from any tank or sewer line.
This system will consist of one 1000 gallon, two-compartment tank followed by a 1000 gallon dosing tank. There
should be a cleanout at any directional change between the house and the first tank. A level manifold will distribute
to 5 rows of 6 graveliess chamber units. There will be a total of 30 units in a bed configuration. The engineer has
specified a maximum cover of 36" for the field.
This department does not endorse any brand of products. This permit must be kept onsite during installation.
The engineer must do a final inspection of the installation and submit an as -built letter to this department. This
department must also be called for an inspection with a minimum of 48 hours advanced notice.
Permit approved by: V(W, (E C) Date:
Plans and specifications of the proposed individual sewage disposal system have been reviewed and are considered
satisfactory. Permission is hereby granted to the owner or the agent to perform the work indicated in accordance with the Pitkin
County ISDS Regulation in effect at the time of issue. This permit becomes invalid 6 months from the date that the permit was
issued unless system construction has commenced or an extension has been approved in writing by the Department.
As -built drawings must be included with this permit before the final approval will be issued.
Installer: Bill Dorals
Final approval: i , i / 1, f") if, r b Date: }
%0 -
& R Septic Service,. Ifte.
Rooter & Jetting Service
Video Inspection Service
0603 Handy Drive
Carbondale, CO $1623
Bill To
Bob Dupre
100 Bear Creek Ln.
Redstone, CO 81623
Date Inv
5/3/22012 7690
P.O. No. Terms Project
Due on receipt
Quantity- DOdiption Rote Amount
. ......
1,500
PuMp septic tank
0.251
--------
375-00
1,500
Dump Fee
0,151
225.00
Sales Tax
3.90%
0.00
Thank you dor your business. 1 CarbondaleAspcn
:Fax
Total $600-00
'(970) 963-3814
(M) 920-2059
(970) 963-6070
LOT 45 /
s.,
4 VC SEWER
INSTALL 1000 -GAL.
SEPTIC i�NEt-(#IIN:)--
i�
1) EFF PIIPI,,*1 ANDSO LE VERT
! ` '^ 1,00
t / StN ANKy�\.1
"A C D0 A,
1� �•3/
J1 rC ` BAC TO NK, t
DISTRISl1 10N L ERA \ f
% /
LOT 4 (BGTH Ds) �
% IN ECTItlN ELL / %✓�
// oPROX PRO, /
n TST LOCA DN
l \I DITCH z
REMOVABLE PVC CAP
_.
INSTALL MARKER IF
3r,\, 1 .,�„''.�� V b C CUTSHO E NRITOP OF
20 0 10
REMOVABLE
INSTALL MA!
CAP IS TO I
FINISH GRADE ---
4" COUPLING
4" SEWER LINE
FLO j
4" x4"x4
PVC WYE
4„ A 1 INFILTRATOR UNIT FOR
SOLID PIPE i (WELL PIP£ON OF INSPECTION SEWE
ROUGHUSE PLASTIC TIE PERFORATED
TO
ENED
HANG 2"0 PERFDRATED PIPE �
IN INFILTRATOR UNITS
OUPLINg
LOTl I� ~ / P� \\ ` • �TREATED ELEC. JCT, BOX
�a / Posr i
�'.
\
12" RISER(S) TO
4" 0 PERFORATED PIPE GROUND SURFACE
r-CAULK/SEAL WELLI ;I