Loading...
HomeMy WebLinkAboutpitkin.eh.272929202017 (2008)OJSITE WASTEWATER TREATII ,VT SYSTEM (OWTS) ZEHINR CONSTRUCTION PERMIT 0405 Castle Creek Road, Suite 10 - Aspen, CO - 81611 Phone: 970.920.5070 Fax: 970.920.5077 Permit #: 08054 Parcel ID #: 2729-292-02-017 Permit Issued: ®NEW ❑REPAIR ❑REMODEL/ADDITION ❑TANK ONLY ❑FIELD ONLY ❑AMENDMENT Owner(s): Peter J. and Mary Louise Menardi Property Address: 50 Ruby Mountain Drive Legal Description: Lot 19, 2nd Addition, Crystal River Park Size of Lot: .63 Acres Size of Building: 4350 sq ft Sq. Ft. Detached Accessory Unit: ❑YES ®NO Size of Accessory Unit: n/a The system is designed for: 3 Bedrooms Master Bedroom Guest Room 1 Guest Room 2 Sq. Ft. Designed By: All Service Septic Project #: 1256 Dated: August 8, 2008 Phone #: 970-618-5033 Mailing Address: PO Box 2844, Glenwood Springs, CO 81602 Fax #: 303-216-2796 Email Address: t etz(Qcomcast.net Perc Rate: 1.2 LTAR Profile Hole Depth: 16 ft Depth to Groundwater or Bedrock: >16 ft Minimum Tank Capacity: 843 gallons Minimum Absorption Area: 563 sq ft w/ no reduction Permit Conditions: This OWTS Construction Permit is approved on the condition of compliance with the engineer design as submitted with the application and the specifications cited above. Changes must be approved by this Department and the engineer prior to construction. This design calls for one 1500 gallon two compartment tank along with an AX -20 Advantex Unit. A drywell will serve as the absorption area. Depth below the inlet must be 12 feet. The drywell will be 12 feet long and 8 feet wide. The drywell shall be filled with clean, graded rock that may range in size from Y to 2 Y inches in diameter. The rock shall extend from the bottom of the well to at least 2" above the inlet pipe. At least one 4" perforated vertical stand pipe shall be attached to the end of the distribution pipe with a tee fitting. A 30 mil PVC liner will be placed on the downhill side of the drywell. This Permit must be kept on-site during installation. The engineer must do a final inspection of the installation and submit an "as -built" letter to this Department within 30 days of the final inspection, unless a longer period of time has been agreed upon, in writing. This Department must also be called for the final inspection with a minimum of 48 hours notice. Minimum horizontal distances between components of the system and physical features shall conform to the requirements of the Pitkin County OWTS Regulation. This Permit is conditioned upon the property owner(s) providing for regular inspection, cleaning, and maintenance of the system by qualified personnel, in accordance with the manufacturer's recommendations and the requirements of the Pitkin County OWTS Regulation. THIS PERMIT IS EXPRESSLY CONDITIONED UPON COMPLIANCE WITH ALL REQUIREMENTS OF THE PITKIN COUNTY OWTS REGULATION, INCLUDING BUT NOT LIMITED TO THOSE CONDITIONS SPECIFIED ABOVE. Plans and specifications for the proposed OWTS have been reviewed and are considered satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated in accordance with the Pitkin County OWTS Regulation. This Permit will expire 1 year from the date of issuance unless construction on the system has commenced. An "as -built" drawing must be submitted and approved by EH/NR before final approval of the system will be issued. Issued By: Installer: 1'd i 3 Final Approval Issued By: (r( ALL Date: (��j r�:'r,' Expires: License #: ()()S Reactivation Authorized by: ) , Date: I / p-5 / 0 Cj New Expiration Date: ❑ Fee Fad ONSITE WASTEWATER TREATMr-NT SYSTEM (OWTS) E�� CONSTRUCTION PERMI . .PPLICATION EH/NR It 0405 Castle Creek Road, Suite 10 • Aspen, CO • 81611 Phone: 970.920.5070 Fax: 970.920.5077 Parcel ID# (available from the Pitkin County Assessor's Office 970-920-5160 or at www.pitkinassessor.org): �--] P--0) –)-C)')L- C I Purpose of Permit: EI NEW ❑ REPAIR DUE TO FAILURE ❑ REMODEL/ADDITION ❑ TANK ONLY ❑ FIELD ONLY Cost of System Repair or Remodel/Addition (approximate): City, State, Zip: Property Address: 50 Ruby Mountain Drive, Redstone, CO Columbus, OH 43235 Lot: Block: Filing: 19 2nd Addition Subdivision: Crystal River Park Property Owner(s)': Peter J and Mary Louise Menardi Email Address: Olivia Emery, R.A. A4 Architects LLC Owner's Mailing Address: City, State, Zip: 1511 ClubvieW South Columbus, OH 43235 Home Phone: Business Phone: 614.846.1118 970.963.676 0 `Contact information must be provided for the owner signing this application Primary Contact Person/Applicant (if not owner): Company: Olivia Emery, R.A. A4 Architects LLC Contact/Applicant Mailing Address: City, State, Zip: 100 North Third St. Suite 201 Carbondale, CO 81623 Cell Phone: Business Phone' 970.963.676 0 Fax Number: Email Address: 970.963.6761 oemery@a4arc.com Building Permit # (if applicable): 0061.2008. P RBK Lot Size (in acres): .63 Size of Building (square feet): Number of Potential Bedrooms: 4350 3 Detached Accessory Unit? YES El NO Size of Accessory Unit (square feet): Number of Potential Bedrooms In or Fixture List for the Accessory Unit: Water Source: ❑ PRIVATE WELL ❑ SURFACE WATER ❑ SPRING ❑✓ COMMUNITY/PUBLIC WATER SYSTEM Name of Community/Public Water System (if applicable): Redstone Water and Sanitation District Engineerin Firm: jJob Number: Phone Number: Fax Number: X;/ A//?–tTA3;� ?a;?,•7//o--�79/n Mailing Address: ary, State, Lip: Z— PLEASE READ BEFORE SIGNING: I certify that the above information is complete and accurate and that I have provided complete and accurate information in all of the documents included in my application package. I acknowledge that EH/NR may revoke any permit I am issued if my application is found to contain any inaccurate, false, or misleading information. I understand that no construction may be undertaken on an OWTS until an OWTS Construction Permit is issued. PO Box 2844 Glenwood Springs, CO 81602 Ph 970-618-5033 Fax 303.216-2796 Pete Menardi 1511 Clubview Blvd. South Columbus, OH 43235 Installation Observations for Menardi Residence 50 Ruby Mountain Drive, Permit #08054 Pitkin County, Colorado Pete, Project No. 1256 ALL SERVICE septic, LLC performed installation observations for the onsite wastewater treatment system (OWTS) on April 16th and 22nd 2009 for the subject property. The installation included a 1500 -gallon, two-compartment concrete septic tank (re -circulation tank) and an AX -20 AdvantexTM unit, followed by a 8' x 12' x 12' deep drywell. A 30 ml PVC liner was placed on the downhill side of the drywell excavation. Four -inch PVC perforated laterals were placed in the gravel to distribute effluent. Two -feet of sand was placed in the bottom of the drywell prior to the placement of gravel. The OWTS was generally installed according to specifications. This observation is not a guarantee of workmanship and/or parts and materials. ALL SERVICE septic, LLC should be notified if changes are made to the OWTS. LIMITS: The observation was based on information submitted and our site visit. If conditions are different from conditions described in this letter, ALL SERVICE septic, LLC should be notified. All additional OWTS construction must be according to the county regulations. The installer should have documented and demonstrated knowledge of the requirements and regulations of the county in which they are working. Sincerely, ALL SERVICE septic, LLC Timothy R. Petz 2 copies sent Copy sent to Pitkin County Health Dept. Reviewed By: Richard H. Petz, Drywell with PVC liner on downhill side. Advantex Unit and observation pipe for drywell. Finished grade. Pro No. 1256 LOT 19, CRYSTAL RIVER PARK ALL SERVICE SEPTIC, LLC PRO. NO. 1255, PITKIN COUNTY, COLORADO PO Box 2844, Glenwood Springs, CO 81602 MENARDI RESIDENCE 970-618-5033 FIGURE 1 • OWTS AS -BUILT DRAWING N stirj '5' 30 SCALE: 1" = 30' Lot 18 X) W op. T1 C 3 SIDE i CLEANOU A._2 'k N 39PI0.378 W 10r 15.796 pll N 3WI0.380 12, W lor 115.794 AX -20 4" SCHEDULE 40 PVC ADVANTEX UNIT PIPE N 39"10.375 MODE3A W 1 or 15.803 1500 -GALLON, TWO-COMPARTMENT PRECAST CONCRETE 12'X 8'X 12' DEEP SEPTIC TANK DRYWELL WITH 30 ML (RECIRCULATION LINER PLACED ON TANK) DOWNHILL SIDE OBSERVATION PIPE LOT 19, CRYSTAL RIVER PARK ALL SERVICE SEPTIC, LLC PRO. NO. 1255, PITKIN COUNTY, COLORADO PO Box 2844, Glenwood Springs, CO 81602 MENARDI RESIDENCE 970-618-5033 FIGURE 1 \rrr �I ISDS DESIGN CALCULATIONS - for Pitkin USING LTAR Owner's Name ��' Parcel ID # ^.: " " " House Size (sq. ft.) (75 gpd or 100 gpd) 75 Number of Bedrooms in Main House i Number of Offices, Libraries, Studies, Similar -sized Rooms in Main House a' x .F Number of Bedrooms in Detached Caretaker unit � Number of Offices, Studies, Similar -sized Rooms in Caretaker Unit 77777 77 (If the caretaker unit is ATTACHED, treat as if part of main house.) Average Daily Waste Flow 450 State Review Required? no LTAR 1M . a...2 (T) Design Flow (Q) = # potential bedrooms X 2 people/bedroom X gpd X 1.5 Q= 675 Minimum tank capacity 843.75 gallons Absorption Area (=B20 X 1.0/317) A = Q x 1.0 loading/LTAR A = 563 sq. ft. of absorption area required absorption area required Abs. Area w/ loacltrg4a&6r- (B25) Trench Pipe and Gravel 506.25 Dosing 450 Chambers 393.75 Max Allowable 28125 Secondary Treatment 562.5 450 506.25 393.75 Quick4 Trench 51.3 45.6 39.9 28.5 Quick4 Bed 57.0 45.6 51.3 39.9 Abs Area w/ out loading factor (B28) Trench Bed Pipe and Gravel 506.25 562.5 51.3 57.0 Dosing 450 450 45.6 45.6 Chambers 393.75 506.25 39.9 51.3 Max Allowable 281.25 393.75 28.5 39.9 100 SETBACK FROM WELL # of feet = 50 SETBACK FROM POND, STREAM OR IRRIGATION DITCH # of feet = 25 SETBACK FROM DRY GULCH # of feet = Pitkin Country Environmental Health Department Contact Log Sheet 11/03/2009 09:20 FAX Z0002/0003 Valley Precast (719) 395-6764 ADVANTEX OPERATION AND MAINTENANCE AGREEMENT Street Address Q 4 1 v t ., WW+ l 1— �� ^ e ( !v Legal Address 0 VPI Inc. will perform operation and maintenance services for the Onsite Wastewater System serving the subject site as outlined below: Control Panel, Pumps and Alarms: During each visit, all electrical components shall be tested for proper function. Correct control settings will be verified. Operations data from panel will be recorded. Processing Tank: During each visit, the scum and sludge layers in the processing tank (septic tank) will be measured. A recommendation for pumping will be made when the scum thickness exceeds four inches, or the sludge thickness exceeds 24 inches. Pumping System: During each visit all pumps shall be observed to verify proper performance. The pumps will be operated manually. The Biotube screen will be removed and cleaned_ Recirculating Filter: The filter will be observed for signs of excess organic build-up or improper performance. The media will be cleaned as necessary. The system will be observed to verify proper distribution across the media and distribution laterals will be flushed. Drain Field: The surface area around the drain field will be observed for signs of failure such as lush vegetation growth or effluent ponding. Liquid levels within the field will be observed through the observation pipe and levels recorded. Items that are not included in this contract include: 1. Corrective and/or repair maintenance if necessary, other than covered under warranty. 2. Effluent sampling and analysis if applicable. 3. The cost of tank pumping. Alarms: VPI will respond to alarm conditions at no cost during the agreement period. Service Calls: Service calls will be billed at a rate of $70.00 per hour and $45.00 per hour for travel time. A visit to the site other than the routine visits provided by this agreement or a system warranty issue will be deemed a service call. Examples would include (but are not limited to) damage caused by acts of vandalism, failure of tank or failure of another party's work, i.e_ electrician, plumber, excavator, etc. The goal of VPI is to observe the operation and perform maintenance for the Onsite Wastewater System to allow for proper long-term function of the system and compliance with the conditions of the installation permit and recommendations of the manufacturer. VPI will perform O&M services as outlined for $265 per visit, with two visits per year ($530 per year). Payment in full for the first ( 3 ) years is required prior to initiation of the agreement. This agreement period will be for the ( 3 )-year period subsequent to placing the system into operation. PIQ fc- 11 I Q/VC*J kno9 Date 9v --37 -��,�% Telephone Number 0q Date 11/03/2009 09:21 FAX 156 390 ■■ on ■■ ■■■ ■■ on ■ ■ ■ ■■ ■ t� s I. ■■■ ■ ■■■■■ ■ ■■ ■ ■ on on ■1•■■ ■ ■■ ■■■ ■ ■■ ■ ■ *dvanTexO Field Maintenance Report Start -Up Summary Report 20003/0003 Valley Precast Inc. (719)395-6764 Property Owner/Tracking k Opergtor Pj J Installed Date Pete Menardi �� 04/21/2009 Site Address Start -Up Date 50 Ruby Mtn. Dr., Redstone CO 81623 11/02/2009 Phone Number Permit K Mode Bedrooms Occupants Occupancy Date (970) 379-7857 Mode 3A 3 Designer/Engineer Phone Authorized Installer Phone All Service Septic, LLC (303) 908-7823 Valley Precast (719) 395-6764 AdvanTex Dealer Phone Electrician Phone SCG Enterprises, Inc. (303) 697-9404 Primary Treatment If fusing a Ejagk Processing Tank, complete the following: t]U1 Processing Tank Septic Volume( /C/�C-) gal.) Recirc Volume( S-6, C,— gal.) Construction /22poncrete ❑ Fiberglass ❑ Other Manufacturer. !/ (, Q If using a separate Septic T and Recirc Tank, complete the following: ❑ Septic Tank ( gal.) Construction ❑ Concrete ❑ Fiberglass ❑ Other Manufacturer. ❑ Recinc Tank ( gal.) Construction ❑ Concrete El Fiberglass ❑ Other Manufacturer. Pump Model: ❑ Floats set properly at -in. -in. -in. Secondary Treatment ❑ RSV setting: -Z �W -in. ❑ Residual head measurement: Pod #1 3 o!� -in. Pod #2 -in. Pod #3 -in. ❑ Discharge Tank/Basin ( gal.) Construction ❑ Concrete ❑ Fiberglass ❑ PVC (Basin) Manufacturer. ❑ Pump Model: ❑ Floats set properly at -in. -in. -in. ❑ Discharge pump Flow rate (drawdown test): ( gpm) ❑ Discharge pump dose volume: ( galJdose) Comments Control Panel Panel ID (RTU or UL #) "On" Timer Setting "Off" Timer Setting RTU115222 Filter Pods Pod #1 Serial No. Pod #2 Serial No.Pod #3 Serial No. 407831 Other System Components ❑ Disinfection equipment (manufacturer): ❑ Dispersal system (type of): De rations (Initial) Orenco's Start -Up Procedure was followed. All fids are secured. Circuit breakers are on and control panel is latched. "For Service Call" label with phone # was affixed to panel. Homeowner Package was reviewed with: Builder on (date) V ❑ Resident on (date) The system is ready for use UYes ❑ No (explain) SignaturDate � � G ax . dform to 1-866-384-7404 mw 09/28/2006 09:36 �(zs- v\J� ( �-tt� 3032162796 "T11I u - Vitt c�,, Pt I �\j m o� PETZ UWP e� 4 A, P -GE 02 1-7?) -o ff -rte -V' IT -P,-A70y S m I-XI,4 %-3-,?,337 (f "V``OZ- r �)AP-)e- - u;-c'r3� iaL 1Zlv�� �PR RK N O- b Pew- VOL -C& F-XAGGV!�) f+O-rD TtE�t5-k 'PM 15 ON 5%b'G OV-' X'4fl MF RgVoD Wm" IFLAG , Tpa�ocv JSP Al b 0 MF-vAR-01 -REStbE0Ck� 1 C s -�U y�lryrU t��� '2006 �l RFso R F S' PO Box 2844 Glenwood Springs, CO 81602 Ph 970.618.5033 SEBVIC Fax 303-216-2796 August 8, 2008 Project No. 1256 A4 Architects, LLC Attn: Olivia, C/O Pete Menardi 100 North 3rd Street, Suite 201 Carbondale, CO 81623 Subsurface Investigation and Revised Onsite Wastewater System Design, Proposed 3 -Bedroom Residence Lot 19, Crystal River Park Pitkin County, Colorado Olivia and Pete, ALL SERVICE septic, LLC performed a subsurface investigation and an onsite wastewater system (OWS) design for the subject residence. The property is located outside of Redstone Colorado, in an area where OWS are necessary. The revision is based on a change in the Pitkin County regulations. The property is served by a community water service. SITE CONDITIONS A single-family, 3 -bedroom residence, having less than 6000 SF is proposed on the property. The proposed drain field area slopes 15% to the southwest. Vegetation consists of native grasses and aspen trees. SUBSURFACE � `0 A The subsurface was investigated by observing the soil profile to the east the residence. Th materials observed consisted of 1 foot of a sandy root zone, underlain b silty, clayey sand, with sparse rocks to the maximum depth observed of 10 feet. Groundwater bedrock was not observed and is not anticipated. An 18 -foot test pit is required prior to construction of drain field. The design is based an LTAR of 1.2 gals/day. A gradation analysis is provided. DESIGN SPECIFICATIONS The OWS design is based on 3 -bedrooms and an average sewage load of 450 GPD. The installation must include a 1500 -gallon, two-compartment septic tank and an AX -20 Advantex Unit, followed by a `drywell' drain field. The drywell must be 8 -ft by 12 -ft, and must be 12 feet deep, for a total area of 576 SF. Perforated PVC laterals, 1/2 to 2 1/2 -inch gravel, and 2 -feet of sand filter material, must be used in the drywell construction. A 30 -mil PVC liner must be placed on the downhill side of the excavation prior to placement of gravel. Construction must be according to the county ISDS regulations, the septic permit provided by Pitkin County Environmental Health Department, and this design. Subsurface Investigation and Revised OWS Design Project No. 1256 08/08/08 Page 2 ADVANTEX OPERATION AND INSTALLATION A qualified installer should install The AdvantexTM Units. A two to three year operation and maintenance contract should be provided by the installer. Additional construction notes are provided on construction figures attached. 1. The control panel should be mounted in `line -of -site' to tank and AdvantexTM unit. 2. A dedicated 15A service for control breaker (in OSI panel) is required. 3. A dedicated 20A service for P30 and P50 pumps is required (1/2 hp or less). 4. If wires from breaker to panel and/or pumps exceed 75 feet we should be contacted to consider 230 -volt recommendations. 5. Conduit should be used for electrical lines. 6. Electrician must provide phone line, if applicable, and terminate in control panel. OPERATION INFORMATION AND MAINTENANCE The surface of the drain field should be seeded upon completion. Vegetation is an important factor in drain field performance. Erosion control should be practiced prior to and during re -vegetation. Geo - fabrics or plastics should not be used over the drain field. Livestock should not graze on the drain field. Plumbing fixtures should be checked to ensure that no additional water is being discharged to OWS. For Example, a running toilet or leaky faucet can discharge hundreds of gallons of water a day and harm a drain field. The homeowner should pump the septic tank every two years and clean the effluent filter as needed. Garbage disposal use should be minimized, and non -biodegradable materials should not be placed into the OWS. Grease should not be placed in household drains. Loading from a water softener should not be discharged into the OWS. No hazardous wastes should be directed into the OWS. Mechanical room drains should not discharge into the OWS. The OWS is engineered for domestic waste only. ADDITIONAL CONSTRUCTION NOTES If design includes a pump, air release valves and weep holes should be installed to allow pump lines to drain to minimize risk of freezing. Excavation equipment must not drive in excavation of drain field due to the potential to compact soil. Extensions should be placed on all septic tank components to allow access to them from existing grade. Precast concrete tanks and distribution boxes should be used, unless plastic or fiberglass is required. Access to all tank compartments and distribution devices is optimal. INSTALLATION OBSERVATIONS ALL SERVICE septic, LLC, and the county must view the OWS during construction. The OWS observation should be performed before backfill, after placement of chambers and distribution pipes. Septic tanks, distribution devices, pumps, dosing siphons, and other plumbing, as applicable, must also be observed. ALL SERVICE septic, LLC should be notified 48 hours in advance to observe the installation. Subsurface Investigation and Revised OWS Design Project No. 1256 08/08/08 Page 3 LIMITS: The design is based on information submitted. If soil conditions encountered are different from conditions described in report, ALL SERVICE septic, LLC should be notified. All OWS construction must be according to the county regulations. Requirements not specified in this report must follow county regulations. The installer should have documented and demonstrated knowledge of the requirements and regulations of the county in which they are working. Please call with questions. Sincerely, C,; • p HERBF'••F ALL SER tic e LLC ( view p 38662 i , Timothy R. tz Richard H. tz, �'SjpNAL EAG\� 3 copies c 0 0 0 O COO O `C N O 6uissed V ''C^i. Oi VJ M z U tw— �' Z m10 U' UJ CO Q. W Qw0 U) 0 M 0 o co N N c C U) U - co Lo N_ O Z N 'f7 I Peter and Mary Louise Menardi 151 1 Clubview Boulevard South J Columbus, OH 43235 Tel: 614.846.1 1 18 November 30, 2007 Mr. Michael Kraemer, Planner Community Development Department 130 South Galena Street Aspen, CO 81611 RE: PERMISSION TO REPRESENT Dear Michael, Please consider this letter as authorization for Mark Chain of Mark Chain Consulting, LLC to represent us in the processing of our application for an Activity Envelope and Site Plan Review. Our property is located on Lot 19, 2nd Addition, Crystal River Park Subdivision (Parcel ID# 2729-292-02-017). Mark Chain is hereby authorized to act on our behalf related to all matters with the land use application. Olivia Emery of A4 Architects LLC is also authorized to act on our behalf. Please contact us if you have any questions. Sincerely, Ma y .. - Menardi MhPAY-28-2098 16:53 From:(:551 6147984064 Tos9709636761 P.2/2 & M ' R)E.DSTONE WATER & SANITA77ON DISTRICT 0215 Redstone Boadevard, Redstone, CelorsAo $1623 (970-464-07d,5) May 16, 2008 Peter Menardi 1511 Clubview Blvd. South Columbus, OH 43235 To whom it may concern: Please be advised that the Redstone Water and Sanitation District blas the ability to serve water to Lot #19, Ruby Mountain Dive_ The owner, Peter Mrnardi has a paid tap and he can connect to the Districts' main at any time. After the connection has been made and before the connection is back tilled it must be inspected by the Districts' operator. Sincerely yours, Brian Ole= District Manager MEMORANDUM To: Suzanne Wolff, Planning Department From: Carla Ostberg, Environmental Health & Natural Resources Department Date: March 14, 2008 Re: Menardi Activity Envelope and Site Plan Review (PID 2729-292-02- 017; Case P182-07) SUMMARY OF RELEVANT PARTS OF APPLICATION: The applicant is requesting Activity Envelope, Site Plan, and Vested Rights for construction of a single family home on a vacant lot in the Crystal River Park Subdivision. The proposed dwelling will have approximately 3,650 square feet of living area. DISCUSSION: The Pitkin County Environmental Health & Natural Resources Department has reviewed the details of the Menardi Activity Envelope and Site Plan Review application under the authority of the Pitkin County Land Use Code and the Pitkin County Onsite Wastewater Treatment System (OWTS) Regulation and has the following comments. Snow cover on the property would have inhibited an effective assessment of the site; therefore, these comments are based on photographs included in the application, as well as a review of the OWTS design by All Service Septic dated November 19, 2007. --- WATER SUPPLY: This property will be provided domestic water by Redstone Water and Sanitation District. In connection with any OWTS Construction Permit for the property, this Department will require a letter from the Redstone Water and Sanitation District confirming they have sufficient water to supply the development and have agreed to do so. --- SEWAGE TREATMENT AND COLLECTION: A proposed OWTS design from All Service Septic, dated November 19, 2007, was included with the application. Considering site constraints on the property, the engineer has designed a dry well to minimize the footprint of the OWTS. As of March 8 2008 new OWTS regulations went into effect which will affect the sizing and requirements for this system. Under the new OWTS Regulation, a drywell to serve a 3 bedroom home with less than 6,000 square feet of living area and a Long Term Acceptance Rate (LIAR) of 1.2 would result in a smaller drywell than under the previous regulation; however, secondary treatment is required Printed on Recycled Paper when dry wells are used for the absorption system. The engineer will need to consider this change in the regulations. All OWTSs installed within Pitkin County require OWTS Construction Permits issued by the Environmental Health & Natural Resources Department, and must comply with the County's OWTS regulations. The County cannot issue a Building Permit until an OWTS Construction Permit has been obtained. Printed on Recycled Paper RECEPTION#: 547903, '/28/2008 at 11:14:29 AM, 1 OF 6, R 00 Janice K. Vos Caudi Pitkin County, CO ADMINISTRATIVE DECISION OF THE COMMUNITY DEVELOPMENT DIRECTOR OF PITKIN COUNTY, COLORADO, APPROVING THE MENARDI ACTIVITY ENVELOPE AND SITE PLAN REVIEW Administrative Decision Noa-2008 RECITALS I ) Peter and Mary Louise Menardi (hereafter "Applicant") have applied to the Community Development Director of Pitkin County (hereafter "Director") to establish an Activity Envelope and obtain Site Plan approval with Vested Rights for a new single-family residence. The parcel is within a designated scenic view protection area. 2) The property is located at 50 Ruby Mountain Drive, and is described as Lot 19, Crystal River Park Subdivision, Second Addition. 3) The lot is zoned RS -30 and contains 0.63 acres. 4) The Director finds that the request complies with the applicable provisions of the Land Use Code, as follows: A) The activity envelope is primarily located on slopes of less than 30%. There are three areas of slopes in excess of 30% - at the northeast comer of the lot where the driveway cuts ofrof Ruby Mountain Drive, to the east of the proposed garage and in the southern corner of the activity envelope adjacent to the neighbor's driveway. The slopes in these areas are due to the presence of minor natural or man-made changes in the gradient of a continuous slope, and qualify as minor slope anomalies pursuant to Sec. 7-20-20(cx3) of the Code. B) The wildfire hazard is severe, and can be mitigated pursuant to the provisions of Sec. 7-20-60.c of the Code. C) The lot is within mapped elk winter range, but according to the Division of Wildlife, the proximity to previously developed lots and the associated disturbance make it unlikely that there will be any significant impacts on wildlife. D) The lot is not within a mapped avalanche hazard area and is below the downslope limit of a mapped potential rockfall area. E) The residence is exempt from the Scenic View Protection standards as it is not visible from Highway 133. APPROVED by the Director, subject to the following conditions, which shall run with the land and be binding on all successors in interest: I . The Applicant shall adhere to all material representations made in the application and shall consider those representations to be conditions of approval, unless amended by other conditions. 2. Prior to submission of any future building permit applications, the Applicant shall be required to submit for approval by the County Attorney and Community Development a Site Plan with an Activity Envelope in accordance with Land Use Code Section 2-30-20(g) and Application Manual Section 2.1.12. The above referenced approvals shall be a condition precedent to finalization and recordation of them. The Site Plan shall also incorporate the following changes: RECEPTION#: 547903 13/28/2008 at 11:14:29 AM, 2 OF 6, Janice K. Vos Cauc , Pitkin County, CO Administrative Decision No. a-2008 Page 2 A.' The regrading for the French drain to the west of the garage shall be contained within the Activity Envelope. 3. The parcel is exempt from the Growth Management up to 5,750 square feet of floor area. 4. Prior to issuance ofa building permit application for the residence, the Applicant shall: A. Obtain a County access/driveway permit. The Carbondale and Rural Fire Protection District shall review and approve the permit, and shall specifically approve the reduction in width of the driveway from 16' to 14' and the adequacy of the turning radius at the entrance of the driveway. Retaining walls in excess of4' in height shall be engineered. B. Submit a drainage and erosion control plan for review and approval by the Planning Engineer. C. Submit a construction management plan for review and approval by the Planning Engineer showing the locations of staging, material storage and employee and construction traffic parking. D. Pay the applicable road and employee housing impact fees. E. Obtain a permit for construction of the on-site wastewater treatment system (OWTS). The system must comply with the new OWTS regulations adopted 3/8/2008. In connection with the OWTS permit, the Applicant shall provide a letter from the Redstone Water and Sanitation District confirming that they have sufficient water to supply the development and have agreed to do so. F. Submit a detailed revegetation plan for disturbed areas with appropriate seed mixes. 5. Areas disturbed by construction shall be re -vegetated within one growing season of the project's completion. 6. No structural development in excess of 30", with the exception of fencing, shall occur within the setbacks of the parcel. Landscaping in the form of berms shall not exceed four feet from the most restrictive grade. Any development located within setbacks mandated by County zoning regulations shall require a variance from the Board of Adjustment. Approval of an activity envelope within such setbacks does not assure approval ofa variance. 7. The Applicant shall comply with the following standards for Development in a Severe Wildfire Hazard Area: A. Defensible Space: The area around all buildings/structures, limited by property boundaries that may limit a property owner's ability to comply with this section, shall incorporate landscaping with wildfire defensible space considerations as follows (note: actual vegetation manipulation to meet these conditions may not be necessary where the natural vegetation patterns have already fulfilled these conditions): 1) Brush, debris and non -ornamental vegetation shall be removed within a minimum ten -foot (10') perimeter around all structures. The large conifer on the south side of the driveway may remain, but shall be limbed to 10', and brush shall be removed within a 10' perimeter of the conifer. 2) Vegetation shall be reduced to break up the vertical and horizontal continuity of the fuels at a minimum ofa thirty (30) foot perimeter around all structures. 3) Clumps of shrubby fuels shall be separated by at least 2 times the height of the fuel, as measured from the edge of the canopy. Clumps should not be larger than 5-T in diameter. Uphill of the house, clumps may be separated by 1 time the height of the field. 4) Ladder fuels underneath larger clumps of shrubs shall be removed. RECEPTION#: 547903 `3/28/2008 at 11:14:29 AM, 3 OF 6, Janice K. Vos Caud , Pitkin County, CO Administrative Decision No. --2008 Page 3 5) All branches that extend over the roof eaves shall be trimmed and all branches within fifteen (15) feet of chimneys shall be removed. 6) All deadfall and dead branches/stems up to an 80' perimeter of all structures (or to property boundaries) shall be removed. 7) All thinned snowberry, serviceberry, or chokecherry stumps shall be painted with Garlon (or equivalent) herbicide to prevent aggressive resprouting. 8) No new conifer trees shall be planted within 20' of structures. Deciduous vegetation is allowed in this area. 9) Within 15' of the structures, vegetation shall be less than 12" tall, except for aspen trees or installed shrubs that are surrounded by irrigated lawns. 10) Within 10' of the structures, vegetation shall be kept to less than 6" tall, unless it is widely scattered small planters, forbs, and other irrigated ornamental species. 1 1) The property owner shall he responsible for the continued maintenance of the defensible space vegetation requirements. B. Roofing Materials: Class A covering or Class A assembly as defined by the currently adopted Building Code. No wood shakes or shingles. All other adopted Building Code compliant methods and materials permitted. Roofs with less than a 3:12 pitch are not permitted unless they comply with the following: I ) All roof coverings shall be constructed of non-combustible materials and installed on a Class A roof assembly. 2) All roof coverings shall have a surface that shall facilitate the natural process of clearing roof debris. 3) Protrusions above the roofline, such as parapets, shall be prohibited, unless constructed as for a one-hour fire resistive assembly, as recommended by Art Hougland, Wildfire Expert (letter attached as Exhibit Q. 4) Roofs shall be installed as required by the adopted Building Code and shall have a minimum pitch of 1:48. 5) All roof designs, coverings, or equivalent assemblies shall be specifically approved by the Fire Marshal prior to submittal of a building permit application. C. Roof Venting: I) Soffit venting shall be located in the outer 1/3rd portion of the overhang. 2) Attic, soffit and other roof venting shall be of non -corrosive metal mesh with maximum ''A" openings. D. Projections at the Roofline, including Soffits, Rafters, Porch or Deck Roofs, Fascias, or Other: One hour rated material or any material underlain by 5/8" Type X gypboard or equal, or "Type IV" Heavy Timber materials, per the currently adopted building code. E. Decks, Decking, Cantilevered Floors, or Other Projections Below the Roofline: 1) Construction with noncombustible or one (1) hour rated material, or material with flame spread <25 (tested to ASTM E84 and listed for exterior use), or 2) Conventionally framed deck with waterproof surface and underside protected with 5/8" Type X gypboard or equal (decking as "a" above), or 3) "Type IV" Heavy Timber materials: joist and beams minimum 6"x10", columns minimum 8"x8", decking minimum 4" in depth, or decking as "a" above; or equivalent log construction, or RECEPTION$: 54790? 13/28/2008 at 11:14:29 AM, 4 OF 6, Janice K. Vos Cauc ., Pitkin County, CO Ad.hd,1rative Decision Na N-2008 Page 4 4) Enclose projection vertically to ground with one hour fire resistive materials. Decking as "a" above. F. Railings: Railings must be constructed of noncombustible or "Type TV" Heavy Timber materials. G. Exterior of the Structure, Including All Walls: 1) One (1) hour fire resistive rated materials, or 2) 5/8" gyypboard underlying combustible materials, or 3) Cement stucco, minimum %" thickness. 4) All glazing to be tempered glazing; and 5) Doors to be metal or wood 1 '/," thick minimum. H. Foundations: Foundations, skirting, and crawl space openings shall be fully enclosed and constructed with materials approved for one (1) hour fire -resistive construction on the exterior side of the wal is and shall extend from the top of grade to the underside of the Floor decking or walls. 1. Maintenance and Miscellaneous Requirements 1) Roofs and gutters shall be kept clear of debris. 2) Roof vents shall be screened with corrosive resistant wire mesh, with mesh one-fourth ('/,) inch maximum. 3) Any outbuilding shall adhere to the same wildfire requirements. 4) Yards shall be kept clear of all litter, slash and flammable debris. 5) All flammable materials shall be stored on a parallel contour a minimum of fifteen (15) feet away from any structure. 6) Weeds and grasses within the ten (10) foot perimeter shall be maintained to a height not more than six (6) inches. 7) Firewood/wood piles shall be stacked on a parallel contour a minimum of fifteen (15) feet away from the structure. 8) Swimming pools and ponds shall be accessible by the local fire district. 9) Fences shall be kept clear of brush and debris. 10) Wood fences shall not connect to other structures. 11) Fuel tanks shall be installed underground with an approved container. 12) Propane tanks shall be buried, if possible, or installed according to NFPA 58 standards and on a contour away from the structure with standard defensible space vegetation mitigation around any aboveground tank. Any wood enclosure around the tank shall be constructed with materials approved for two (2) hour fire -resistive construction on the exterior side of the walls. 13) Each structure shall have a minimum of one ten (10) pound ABC fire extinguisher. 14) Addresses shall be clearly marked with two (2) inch non-combustible letters and shall be visible at the primary point of access from the public or common access road and installed on a non-combustible post. 15) Utilities shall be extended underground. 8. The Applicant shall comply with the following to mitigate impacts on wildlife: RECEPTION#: 547903 13/28/2008 at 11:14:29 AM, 5 OF 6, Janice K. Vos Cauo , Pitkin County, CO Administrative Decision No. a-1008 Page 5 A. Dogs shall be kenneled within 50' ofthe residential buildings or leashed under human supervision when outside the kennel. Construction workers shall be prohibited from bringing dogs on-site. B. Pets shall be fed indoors, and pet food or food containers shall not be left outside. C. Manipulation of vegetation outside of the activity envelope is prohibited. D. New fences shall comply with the following: 1) Mesh or woven wire fences are prohibited. 2) Wood rail fencing shall employ three (3) rails or less, be the round or split rail type, shall not exceed fifty-four (54) inches in height above ground level, and twelve (12) inches in width (top view), and shall have at least eighteen (18) inches between the lower two (2) rails. 3) Wire fencing must be three (3) strands or less. The top wire should be a twelve -point -five (12.5) gauge twisted barbless type at a maximum height of forty-two (42) inches. The middle strands (which may be barbed) should be located a minimum twelve (12) inches apart and from the top wire preventing entanglement when mule deer jump over. The bottom strand should be sixteen (16) inches from the ground. Fruit bearing trees and shrubs shall be prohibited. Trash/garbage shall be kept in an approved bear resistant container or enclosure. 9. The Applicant shall comply with the following measures to mitigate for potential rockfall: 1) Final grading and landscaping shall incorporate continuous or overlapping topographical separations of at least 6' upslope from inhabited structures (berms, overlapping mounds); 2) Stiffening of upslope foundations sufficient to withstand an impact of 600 pounds per square foot for 6' above final grade, with no significant openings in this interval; 3) If upslope foundations can be angled towards the hazard, stiffening can be reduced to 4' above final grade and able to withstand an impact of 500 pounds per square foot. 10. No development shall occur outside of the approved activity envelope, with the exception of vegetation removal necessary to comply with the wildfire mitigation measures described above. H. Prior to commencement of any earthmoving or other construction activity, the Applicant shall stake the corners of the envelope and install construction fencing around the construction site within the perimeter of the envelope. The fencing shall remain in place until issuance of a Certificate of Occupancy. 12. The exterior materials (facade and roofing) for the residence shall have natural earth tone colors that blend with the colors of the surrounding landscape and shall be non -reflective. 13. No calculations for height, bulk, setback, size, floor area, or any other building and zoning requirements have been conducted. These requirements will be considered at the time of building permit Any structures represented in the application may not be permitted under building and zoning regulations. 14. Statutory vested rights for the approval contained herein are granted pursuant to the Pitkin County Land Use Code and Colorado Statutes, subject to the exceptions set forth in Pitkin County Land Use Code, §2 0-170 and C.R.S., § 24-68-105. The statutory vested rights granted herein shall expire on Yfi M , 2011. 15. Failure to comply with the conditions of this approval may result in revocation of this approval, or any subsequent permit(s) or approval(s) related to this property, or vested rights associated with this property. RECEPTION: 547903, '/28/2008 at 11:14:29 AM, Janice K. Vos Caudi Pitkin County, CO Administrative Decision No. 2,4 -2008 Page 6 NOTICE OF PUBLIC HEAKING YUtfLISHM) IN I HL AJrLIN I lmr,yyr r lll.I on me 10'" day of February, 2008. APPROVED by the Director, this ?b.Lday of� 11",j 2008. PUBLISHED AFTER ADOPTION FOJR VE TED REAL PROPERTY RIGHTS in the Awn Times Weekly on the a day of, 2008. Ci y Houben, Community Development Director PID# 272929202017 P182-07 0 z o o N O < � U 0 w 5 Z W N < W Nw & Z "� N 2< 2 p C a C- LL N CL Q x O Z p N i N µW LLO W O O p o N ti d 0 z o O < � U 0 w 5 Z W N < W 8 Z OV d < N x pW 1> O Z W W N K N µW LLO W N d �m O d Z� E d r O W Q II r U O V7 rl Z In 9 91 Z U N N O C V Zo LU IXOQL H U) �Q0,z oQU9°U NZ _ W H 0 z U ��rnW�ug V w0�Qx} w W N N W Q H z Y ¢w UHO ZZ a00aU QOW�wW f- O=af U(n Li a z 0 .a W pq o 0 (U - Y N m w 0 C 00 am W D aw M O� �o x 55 X FO O NO 0a0Zg OQhQ�U �UaWY \ $llWa.Q Fam_.ti i Z 0 U) Z Q LL LL z ww0 a W m j~ J g wLL. 0UU ° 0 SO � U> 02 �w N O W r � m X WO 09 -we � r (AZZ U-ZQU 0 j Z N N 0 0 7 O° W 'Z,, j O 11 Q (DQ� 0 �LL Z�nU00 W �rn Y LL 8- W W O O W~ Z w U 3�3 ap N� UK Z K W ZQO LL U JJJ o�ozm W6 W QHwK J II�pW O w W O 000 m-1 V)�OQ O O W N m >0 w U W� Z J W ~ w Q m J LL_ ;I; sW w_ 3 ? °cgigo OH ~ U W Q UO W OW w= 9 F rc aW Z U 0� z gQwom�Jvi �cu Uw ak 0 > OFLL UJ N w : w°m JLL ao 0 > U F N U K y 0 F~ 1 \ O0� U 0° LL U U 9 7 w �QpZ�z�Ocn �K J J W _o U(:J ><nF a? �a ow 0 OW 5 LL rJoLL W U W mI i W aWW W5� '0' JLL LU � ow o o m WQ �aC� r� 3� :nm LL OF mOO W m Y SjT W Z Z F y m Oma Z �F m�� g a. ZN Zo LU IXOQL H U) �Q0,z oQU9°U NZ _ W H 0 z U ��rnW�ug V w0�Qx} w W N N W Q H z Y ¢w UHO ZZ a00aU QOW�wW f- O=af U(n Li a z 0 .a W pq o 0 (U - Y N m w 0 C 00 am W D aw M O� �o x 55 X FO O NO 0a0Zg OQhQ�U �UaWY \ $llWa.Q Fam_.ti i D 0, Z a w a w LL X ¢ o0 Z) U., ywwLUo ao wQ:U �rzwZUz arp Wzp moo F- n zZ¢ W I -a ¢Wp�>�n> cDwooo¢ z¢ J o W y X F-zwcnaUw X0FWomo 0nw3:¢uWio_ Z F n 2 O -wUo�-.0 F 2 =U LLIw U W w :D � m > _ 10 v~ipLL =awOz Uo t- a U ¢ U (D W 0 LU V U) 0i LW 1r n V W V J Z O 0 w V W ry Q O 40 O W /�0z J U LL } C Cl)Zu O UUC z EX ~H LL OJ E Z U J J U c m w g U_ ui LLI a w 02 JoZ°b m Q 0. 0 U) Z Q LL LL z ww0 a W m j~ J g wLL. 0UU ° 0 SO � U> 02 �w WQ�o�Z 3U0WWZ0�Q W r � m 09 -we + QLL,° �U (AZZ U-ZQU 0 j Z N N 0 0 7 O° W 'Z,, j O 11 Q (DQ� 0 �LL Z�nU00 W �rn Y LL 8- W W O O W~ Z w U .J.. �".. 1 11 IQQI ap N� UK Z K W ZQO LL U JJJ o�ozm W6 W QHwK J II�pW O w W O 000 m-1 V)�OQ ( Zwoop O W Z Z m >0 w U W� Z J W ~ w Q Q}HU J 0LL0 w_ 3 ? °cgigo OH ~ U W Q UO W OW w= j �w 0U aW Z U 0� z gQwom�Jvi i �U)UZp�� Uw 'o> a H °a�zpz3=� W 0 OU J 0 Z R UJ N w m Z)O _ S w 0 m O U Z> m> Y° S u- F- 2 y Q 0 > U F N U K y 0 F~ 1 2< W U U 0° LL U U 9 7 w �QpZ�z�Ocn iZ J J W _o U(:J ><nF Q W JOtn UW gw-Om F- 5 LL rJoLL W U W mI i W S O Q z JLL LU � ow o o m D 0, Z a w a w LL X ¢ o0 Z) U., ywwLUo ao wQ:U �rzwZUz arp Wzp moo F- n zZ¢ W I -a ¢Wp�>�n> cDwooo¢ z¢ J o W y X F-zwcnaUw X0FWomo 0nw3:¢uWio_ Z F n 2 O -wUo�-.0 F 2 =U LLIw U W w :D � m > _ 10 v~ipLL =awOz Uo t- a U ¢ U (D W 0 LU V U) 0i LW 1r n V W V J Z O 0 w V W ry Q O 40 O W /�0z J U LL } C Cl)Zu O UUC z EX ~H LL OJ E Z U J J U c m w g U_ ui LLI a w 02 JoZ°b m Q 0. 0 LL Q LL LL 0UU W r � m + j Z N N m LL j O 11 Q (DQ� ZF Q W W LLIWL LL N N r >w 11 N �rn W LLm F- N II Q II (V X .J.. �".. 1 11 IQQI L)a) II W j LL U JJJ O w XNXa ? II�pW WLW m N_ O ( Zwoop �`° n z Q}HU J 0LL0 Qa °w U) 0 00�¢ ? °cgigo w o°0 uwi cul j �w 0U mPX: HzEL Q a i �U)UZp�� 0< d D 0, Z a w a w LL X ¢ o0 Z) U., ywwLUo ao wQ:U �rzwZUz arp Wzp moo F- n zZ¢ W I -a ¢Wp�>�n> cDwooo¢ z¢ J o W y X F-zwcnaUw X0FWomo 0nw3:¢uWio_ Z F n 2 O -wUo�-.0 F 2 =U LLIw U W w :D � m > _ 10 v~ipLL =awOz Uo t- a U ¢ U (D W 0 LU V U) 0i LW 1r n V W V J Z O 0 w V W ry Q O 40 O W /�0z J U LL } C Cl)Zu O UUC z EX ~H LL OJ E Z U J J U c m w g U_ ui LLI a w 02 JoZ°b m Q 0. 0 1' � g�^S�'Mf '� '.7 xYD'._ ._. ,t YL. •'� \' y', 3' d,1F. Z + C4 _ � $ J _ - � .��y tom" O� �_-� ^�y •5 � �i � � a ESf � a- b • . 0a N WWW W O+ m T P. a� g�', Got"x Y O ,•�7',�Ou1ei �� .:-'t, _ � a+ p .�- :� *: tu NFZ �* O<LL ..LL W t�OI S~Y F- F'L J o Z<<2 Z LLW�17i w t0 W Q <W o Z N Nuc �_<.� o N@�p[ N _,N <.i.!�az �L a F W.� :.Y2 Z < 2_.. ww Z� p Z <YC Z jX K•�Q Kw� 4W bC z BW �w ly ,00 < HW6 WN�S<p. < -HOE -x� V .�LLYC <CR OC +.Weo[-, 'U .u.2WN �O WW E <.�� LL�LL<�< ONLLW w1- .iii - t •.,I ( �. tr�� LL W Z�W<JLO I�iI�WYI t=tjNW w i \ Vi � e[�e[�I[ww�e[�eC�°t���30W=�� .. Q"3IGNR`m�N. ZD < W Z = ZUU O W Q \ MTV V gga <� m len � 3 O L - ] F \ R1 01 16<2 ZZ 505 9 <�ul b:. ttl4 ♦ Edi \\ '\ ♦ \ ♦♦� \�. \ ♦ m0 Mg OD LLQ 's3 • I T \ .� �'\` \ '— �_ �/< ` m l_� �k ♦! / � ��7 ♦ l - il: d tF � � ,� 1 � , I ♦ I \ \ tr .► - _ - w ib W F 0 x; ~� 8v oz<oM 2 z�Wy� pp tOQ<Z .. _zmO Olal 9i'ym c� w_ ..tom w„oma O W =W? N Y O 9 < Z ,U Z? c-p)U F- o [� Z < 2 F �j �_ �% p i.. .•% Nig} i :. - - z << R! SSS dGWW N� p r¢pQ Z SCALE 1„ = 20' N❑RTH a b nN" ss,, Lot 18 wo. c v x CUT �� •�, ''o )��, SSONESte, RETAINING' j '• •` h� 9U `. NA]L �• x11'n /� • �� � y ATn F • ` '�, // )RON �� \ �• LPRILL �� SON _ r—BURIED PROPANE TALAR 9I001 1.116.0' P �. �.\ mower 1L6:0'� / IN +� � / c nN r nry N uP vy� moN �• ,x ��rn Rn _ LOT 19 �(� ��IOOleRINS o _. / 0.63 AC 3- EDROO s' K9 DEN G a F " CE" E /)i CLEANOUT ,--�s°V° i'� SINGLG (X)PORaRA05A PINE 000 i• �...--, RoweASc DRIVE �••/ .:: Lot 20 !� " i �' n,A� . p03 I a _ 92s 4" SCHEDULE 40 PVC PIPE 12'X8'X12'DEEP ' DRYWELL WITH 30 ML LINER PLACED ON DOWNHILL SIDE OBSERVATION PIPE THE LOCATION OF EXISTING AND PROPOSED IMPROVEMENTS SHOWN ARE NOT THE RESULT OF A PROPERTY SURVEY. THE LOCATIONS ARE APPROXIMATE. IT IS THE HOMEOWNERS DUTY TO ENSURE ALL CONSTRUCTION AND IMPROVEMENTS LOCATIONS ARE ACCURATE. ALL SETBACK DISTANCES SHOULD BE CONFIRMED PRIOR TO EXCAVATION. ua' "�—NF,ICNb'JR'8 -y1 eTi^IG AX -20 ADVANTEX UNIT MODE 3A 1500 -GALLON, TWO-COMPARTMENT PRECAST CONCRETE SEPTIC TANK (RECIRCULATION TANK) AdvanTex Treatment System AX 20 Series - Mode 3a Pirate Return Line —� Slope (min. 1 /8"/k.) Inlet Inlet Recir with Met 1500 -GALL TWO -CON SEPTIC TF Discharge Filtrate To Drain Field AdvanTex Filter a TANK SPECIFICATIONS Side View CROSS SECTION CAPACITY REQUIRED= q X 1.5 X (30 HOURS/24 HOURS) = 844 GALLONS REQUIRED TANK(S) = 1500 -GALLON, TWO-COMPARTMENT, CONCRETE SEPTIC TANK WITH AX -20 SECONDARY TREATMENT UNIT SWEEP 12 WAY CLEANOUT DETAILS (N.T.S) TYPICAL FINISHED GRADE IZ SEWER LINE SC V—t— SCHEDULE 40 P.V.C. \ PVC CAP DO NOT GLUE EFFLUENT LINE -4" SCHEDULE INSULATED COPPER 40 OR 4" TRACER WIRE MAY SDR 35 BE INSTALLED TO P.V.C. LOCATE LINE IN FUTURE ADVANTEX-20 NOTES: 1. CONTROL PANEL SHOULD BE MOUNTED IN 'LINE OF SIGHT' TO TANK AND AX UNIT 2. DEDICATED 15A SERVICE FOR CONTROL BREAKER (IN OSI PANEL) REQUIRED. FOR 115V PUMPS A 20A SERVICE IS SUFFICIENT. 2" Dia. Vent Dia. PVC Riser/Lid :omportment Tank ,,.,,;ube® Pump Pockage 4" OF GRAVEL PLACED ABOVE LATERAL / End View NATUKRAT 1.5' GFtPDE o , ° 10' a ° 3" OR 4" PERFORATED PIPE MUST BE USED, PLACED IN ° TOP 1 FOOT OF GRAVEL 2' 8' 30 Mil PVC LINER ON DOWNHILL SIDE ASTM C-33 SLOTTED PVC OBS. PIPE CONCRETE SAND GEO-FABRIC DISPERSAL GRAVEL (2' TO 2 i") TO EXTEND TO BOTTOM OF DRYWELL DRYWELL DRAIN FIELD SPECIFICATIONS SWALE OR BERM TO DIVERT PLAN VIEW SURFACE RUNOFF—_-'---_- INLET UNOFF ---_- INLET LINE FF SEPTIC TANK 3" OR 4" PERFORATED PIPE t MUST BE USED 12' 30 Mil PVC LINER ON DOWNHILL SIDE DESIGN 3 -BEDROOM MAIN RESIDENCE, >2000 SF = 600 GALLONS PER DAY TOTAL LOADING = q = 600 GALLONS PER DAY SAND, CLAYEY LOAM (LTAR) = 1.2 GALS/SF/DAY CALCULATED AREA = ((1.5 X q) / 1.2 = 563 SF NO REDUCTION DRYWELL SPECIFICATIONS WIDTH OF DRYWELL = 8 FEET LENGTH OF DRYWELL = 12 FEET DEPTH OF DRYWELL = 12 FEET AREA BOTTOM (8X12)=96 SF✓Wxi SIDES (8 X 12) X 2= 192 SF --Ax W x 2 - SIDES = (12 X 12) X 2 = 288-6F SIDES=(12X12)X2=288-6F dX I xZ TOTAL AREA PROPOSED: PROPOSED NEW INFILTRATIVE AREA = 576 SF NOTES: LIMIT OF EXCAVATION 2' OBSERVATION PIPE DRYWELL MAY BE ANGLED TO FIT TOPOGRAPHY AND TO MINIMIZE REMOVAL OF EXISTING VEGETATION. THE SLOPE AT THE PROPOSED DRAIN FIELD IS APPROXIMATELY 15% TO THE SOUTHWEST. VEGETATION CONSISTS OF A FULL COVER OF NATIVE GRASSES. LIMITATIONS - THESE PLANS MUST BE USED IN CONJUNCTION WITH LETTER AND SOILS DATA FORM PROVIDED. THE DESIGN IS BASED UPON INFORMATION SUBMITTED. IF SOIL CONDITIONS ENCOUNTERED ARE DIFFERENT FROM CONDITIONS DESCRIBED IN REPORT, ALL SERVICE SEPTIC L.L.C. SHOULD BE NOTIFIED. ALL OWS CONSTRUCTION MUST BE ACCORDING TO COUNTY REGULATIONS. THE INSTALLER SHOULD HAVE DEMONSTRATED KNOWLEDGE OF THE REQUIREMENTS AND REGULATIONS OF THE COUNTY IN WHICH THEY ARE WORKING. THE COUNTY AND ALL SERVICE SEPTIC L.L.C.MUST VIEW INSTALLATION LOT 19, CRYSTAL RIVER PARK Project NO. 1256 ALL SERVICE septic, LLC PO BOX 2844 PITKIN COUNTY, COLORADO REVISED ONSITE WASTEWATER SYSTEM DESIGN GLENWOODSPRINGS, C081602 jMENARDI RESIDENCE _ 08-08-08 970-618-5033