Loading...
HomeMy WebLinkAboutpitkin.eh.272929203010 (2016)'K I N Pitkin County Environmental Hlealth Department ii Onsite Wastewater Treatment Sy, -,-m (OWTS) USE PERMIT COUN*''I Permit for Continued Use of an Existing OWTS all 76 Service Center Road, Aspen, CO 81611 Phone: 970-920-5070 Fax: 970-920-5077 www.aspenpitkin.com/EHNR Parcel ID #: 2729-292-03-010 OWTS Use Permit #: I 0020.2016.POWU Date Issued: 06/24/2016 Issued By: Bryan Daugherty Expiration Date: 6/24/17 Owner(s): Jim Byers Property Address: 152 Elk Lane Legal Description: Lot A10 & A10 -A, Redstone Ranch Acres Licensed Inspector: Carla Ostberg Inspection Date(s): 5/31/16 SYSTEM INFORMATION Components Type Capacity/Size Primary Treatment Unit Concrete 3 -compartment tank 1250 gallons Secondary Treatment. Unit Absorption Area Gravelless chamber bed 1169 ftz Other System Components Dosing Siphon N/A ®In use at the time of the inspection. L]Not in use at the time of the inspection.* *If the OWTS was not in use at the time of the inspection, it is recommended that the system be re-evaluated when it is in use for a more accurate evaluation of the system. System Records: Permit #: 06010 Date of Issuance: 3/2/06 Date of Final Approval: 7/30/07 # of Bedrooms or fixtures served by OWTS: The system is designed to serve 3 bedrooms Operational Status: The inspector indicates the system is properly functioning and there is no evidence of failure. The tank was in good working condition and the dosing siphon functioned at the time of inspection. The tank had to overfill slightly for the dosing siphon tofunthdrrbut did not impact the watertightness of the tank. The soil treatment area appeared to be functioning properly mo`.stan.ding water was in the inspection ports. Inspector Recommendations:,'RtOpair,alarm float Department Recommendations: antwalxnaintenance Issuance of this OWTS Use Permit is based solely on the conditions observed and reported by the inspector to the Department on the date of the inspection(s) and on Department records at the time of permitting. The issuance ofthis permit does not constitute a guarantee, warranty, or representation by the Department that the system will operate properly or will not fail or that the system will not be subject to future enforcement action to correct non-compliant conditions. Estimated capacity of the system has been listed on the permit and we recommend that you monitor and/or meter water use to prevent overuse and possible failure. VPitkin County Environmental Health Department 1 "f' 3K I N Onsite Wastewater Treatment System (OWTS) "COU NxUSE PERMIT APPLICATION 76 Service Center lid Cc ;, "4;) �` �` Aspen, CO 81611 Website: www.aspenpitkin.corntehnrl ADolication for Continued Use of an Existina OWTS Parted IDS (aysllable from the Pitkin County Assessor's Office Company 970-920.6160 or at www.oItklnass@ssor.orot: Gty. State, TJp Cell Phone: Purpose of Use Permit: NKOPOM TRMSACTION ❑ REMODELJADDMON Indicate Preferred Method of Permit Receipt: ❑ EmaO [3 Fax ❑ US Mag 15-2 J Lot Block:Flung: SubdMsion. 1 �- o'� e, Residences: Other K of Bedrooms: fixturesluses: Property 5)% Email Addrm. Owners MalMnq Address: City. state,zip: Home Pho Business Phone 'Contact lnfbrmatlon must be provided IrorNre owner s+gning this appscahon. Primary Contad PemWApp6cant (i(not owner): Company ContactlApplicant Malling Address: Gty. State, TJp Cell Phone: Business Phone Fax Number. Email Address Indicate Preferred Method of Permit Receipt: ❑ EmaO [3 Fax ❑ US Mag 4 PLEASE READ BEFORE SIGNING: " I codify that the above Information Is complete and accurate and that I have provided complete and accurate Information In all of the documents Included In my application package. I acknowledge that this department may revoke any permit I am Issued If my application Is found to contain any Inaccurate. tats@, or misleading Information. �ercwm s+gnawre t7C) t C Me � Please allow 3-5 business days for processing of Use Perrnfts OFFICE USE Ofd: Y Ived by EH Staff I" & Receipt p - Date Jerome Whalen From: Carla Ostberg <carla.ostberg@gmail.com> Sent: Friday, June 10, 2016 9:21 AM To: jim_byers@blm.gov; Jerome Whalen Subject: 152 Elk Lane OWTS Inspection report Attachments: 152 Elk Ln OWTS Inspection Packet.pdf; invoice 827.pdf Jim and Sarge, Attached is the inspection report. Let me know if you have questions about the permitting process. I would like to shoot Kurt an email when you are ready to submit and talk to him about us not replacing the float switch. While it was not required by code, it was part of the original engineer design of the system. I think if I explain the complications and time needed to order the part, he will just make it a recommendation rather than a requirement. My invoice is also attached. Thanks! Carla Ostberg CBO Inc. working with ALL SERVICE septic cell) 970-309-•5259 office) 970-704-0484 33 Four Wheel Drive Road Carbondale, CO 81623 I 7oa4� June 10, 2016 Jim Byers Jim byers(aD-birn gov CBO Inc. 33 Four Wheel Drive Road Carbondale, CO 81623 cell) 970-309-5259 office) 970-704-0484 carla.ostberg(a-)_gmail.com Onsite Wastewater Treatment System (OWTS) Use Permit Inspection 152 Elk Lane Pitkin County, Colorado Jim, As requested, CBO Inc. performed an Onsite Wastewater Treatment System (OWTS) Use Permit inspection at 152 Elk Lane, Redstone, Colorado May 31, 2016. The legal description of the 0.9 -acre property is Lot A-10 and Lot A10 -A, Redstone Ranch Acres Subdivision. The permit and record drawing was provided by Pitkin County Environmental Health Department (Parcel ID #2729-292-03-010). The subject OWTS consists of one 1250 -gallon, three -compartment concrete Front Range Precast septic tank with an effluent filter between the second and third compartments and a dosing siphon in the third compartment. Effluent is dosed to a gravelless chamber bed with 9 rows of 10 `Quick 4' Infiltrator® chambers (1080 square feet of infiltrative area). Individual Sewage Disposal System Permit 06010 documents this system. The system was sized to accommodate 3 bedrooms. The existing residence has only one bedroom. Floor plans are provided in photographs below. A clean out is located in the concrete with a removable cast iron cap in front of the entry door to the residence. The septic tank is located on the southwest corner of the residence. All three manhole lids were accessible from grade. Liquid levels in the septic tank appeared to be normal prior to pumping. B&R Septic pumped all three compartments of the septic tank during our inspection. We attempted to fill the third compartment of the septic tank with a garden hose to activate the dosing siphon. This attempt was made after pumping began. We later noted that the high water mark on the plumbing in the septic tank was higher than the pass through between the second and third compartments. What this means is that in order to activate the dosing siphon, the tank must overfill slightly. To test this theory, the pass through between the second and third compartments was plugged and the third compartment filled with a garden hose (photos below). When the liquid level got to the high water mark on the plumbing, the dosing siphon activated normally. The dosing siphon will continue to operate normally once the septic tank has re -filled from pumping. An effluent filter is present on the outlet tee of the second compartment. This filter was cleaned as part of the inspection. There is an audible alarm on the filter; however, it is not working. The float switch may need to be replaced. The control panel for the alarm is located in the garage. The TEST button on the control panel is audible. As this type of filter/alarm combination is not something that is typically used in the area, it will likely have to be special ordered. We have enclosed specifications for the alarm switch. Valley Precast out of Buena Vista is a PolylokTm distributer and may be able to order the part. The baffle between the second and third compartment of the septic tank is showing signs of deterioration but is still intact. Effluent is dosed to the gravelless chamber bed. Inspection ports were present on all four corners of the bed. All inspection ports were dry at the time of our inspection. We walked the soil treatment area (STA) and there was no evidence of surface saturation and no evidence of failure at the time of the inspection. Recommendations: • Clean effluent filter annually, or as needed. • Replace float switch of the audible alarm on the effluent filter. This evaluation is not a guarantee of future system performance. This inspection is good for one year. This report must be submitted to the Pitkin County Environmental Health Department. The following links are the required application and application checklist. Application: htto://www.oitkincountv.com/DocumentCenter/Home/View/621 Application Checklist: http://www.pitkincounty.com/DocumentCenter/Home/View/620 Disclaimer. This inspection is intended only as an evaluation of the present condition of the OWTS based upon what was observed and the Licensed Inspector's expertise in onsite wastewater technology. The Inspector has not been retained to warrant or guarantee the proper functioning of the system for any period of time in the future. Because of numerous factors which may affect the operation of an OWTS, as well as the inability of the Inspector to supervise or monitor the use or maintenance of this OWTS, this report shall not be construed as a warranty by the Inspector that the system will function properly for any particular prospective buyer, and the Inspector disclaims any warranty, either expressed or implied, arising from the inspection of the OWTS or this report. The evaluation does not ascertain the impact the system is having on groundwater. Please call with questions. Sincerely, O,,. .. o� Carla Ostberg, MPH, REHS NAWT Certified Inspector Certification # 1,10441TC Exp. April 2018 u Clean out in front of entry door Septic tank E 1st compartment Second compartment Effluent filter lent Note high water level in the compartment Note high water level on the overflow pipe Plugged the pass through between 2nd and 3 d compartments to test 0 el got to high water mark .� Alarm control panel located in garage Soil treatment area (STA) Inspection ports Inspection ports Inspection ports dry • Floor plans I N Onsite Wastewater Treatment Systems (OWTS Permit Inspection Form [ CA) V NIN' Pitkin County Environmental Health Department 76 Service Center Rd, Aspen, CO 81611 Phone: 970-920-5070 Fax: 970-920-5374 Website: %yAV.asRern itkin.corn/ehnr p TInsoection form for continued use of an existing OWTS Owner's Name: Address: Parcel Number, Inspection Date; Inspector's Name Business Name Phone Numbe Email Pitkin county Systems inspector License Number, gasses or fails. PRIOR To INSPECTION: QUESTIONS F60 YES NO is the home currently occupied? Xl If No, how long has the home been vacant? How many bedrooms are in the home? if secondary treatment is used, who is the maintenance provider? RECORDS: ? YES I NO Were system records available from Pitkin County if YES: Permit number: a - Date of Final Approval. i # of bedrooms permitted: ................. 11W drawing available? YES NO Was an as -built NO YES is the as -built drawing accurate? 111as accurately as Complete a drawing of the system on lost page of this form possible. before an OWTS Use permit is issued. IL will require correction CONDITIONS: 7rop'Ce PA 11�� FAIL r grad of erosion? "'Va YES improper vegetative cover? machinery or livestock? as heavy m j NO YES FAIL fVidence of compaction such oc ctralaht pipes? P YES TANK: Tank 1 Tank 2 ffluent surfacing? evidence of past surfacing? Tank 3 YES Tank Tank capacity L) gallons YES gallons Pot gallons Tank material m t NO YES inches WIf YES, record depth: WI Box or ADV part of original design? YES N UNKNOWN --eO of compartments YES is it level and in good condition? PASS FAIL Dateof I st P, atecof last pumping Page 2 Lids/risers in gocW condition PASS ,. FAIL PASS FAIL PASS FAIL Risers to grade NO YES NO YES NO Riser height Riser condition/watertightness Inlet sanitary T/baffle--'-OAS 1Outlet sanitary T/baffle— _4,�* FAIL - FAIL PASS PASS FAIL FAIL PASS PASS FAIL FAIL Effluent fitter (if part of design) All. N/A PASS FAIL N/A PASS FAIL N/A Condition of tank material FAIL PASS FAIL PASS FAIL ITank was pumped for inspection I If YES, list the pumping company Y NO YES NO YES NO If NO, when was the last pumping Iscurn level (1st compartment) inches inches inches ISludge level (1st compartment) inches inches inches IScum level (2nd compartment) inches inches inches ISludge level (2nd compartment) inches. inches inches Backflow (if pumped) PASS FAIL PASS FAIL PASS FAIL Midtank baffle �Watertisthtness FAJL N/A PASS FAIL N/A PASS FAIL N/A 0ASSC,, FAIL PASS FAIL PASS FAIL PUMPSIDOSING SIPHONS: is a pump or dosing siphon present? YES NO If YES, Is the pump/dosing siphon functioning properly? PASS FAIL Does the pump/wiring/dosing siphon appear to be in good condition? PASS FAIL is the high water alarm working, both visible and audible? PASS FAIL SECONDARY TREATMENT: is a secondary treatment unit present? YES UNKNOWN if YES, does the unit appear to be in good working condition? YES NO Woes the owner have a current maintenance contract for the unit? YES NO UNKNOWN aintenance Provider: Phone. if there is no maintenance contract, a contract must be in place prior to occupancy of the home A copy of the contract must be submitted to Pitkin County Environmental Health Department. 7' . ..... ... p�,- tMIM,-, 9SOMON AREA: P IAW FAIL ffluent surfacing? evidence of past surfacing? 1--i- 1-1 r—?N YES urface dampness? I YES ceuive odors? ports or probing: leld location verified by observation Pot YES Probing observation port? NO YES inches WIf YES, record depth: WI Box or ADV part of original design? YES N UNKNOWN --eO if YES, is it accessible from grade? YES is it level and in good condition? PASS FAIL h Page 2 Any problems with the system that were not addressed in the inspection checklist? "° Please list any recommendations for the continued use of the system: Z I Were any repairs clone as a result of this inspection? . NO , YES if YES, please describe the repairs. ---------- - To the best of m knowledge and training, the information collected in this inspection is accurate as of f WE age 4 Pitkin County Environmental Health Department Permit for an Individual Sewage Disposal System 0405 Castle Creek Road, Suite 10, Aspen, Colorado 81611 Phone 970-920-50701 FAX 970-920-5077 Permit # 06010 Parcel ID # 2729-292-03-010 Type of permit New :X } Repair( ) Addibon/Remodel to House( ) Name of Owner James C. Byers Street Address Elk Lane, Redstone Property legal description Lots A-10 7 A-10 A, Filing 2, Redstone Ranch Acres Subdivision Size of lot .9 acres Total square footage of the house 1,800 Water source Private well # of bedrooms in house 1 # of offices, lofts & similar sized rooms in house Caretaker unit Total square footage of the caretaker unit # of bedrooms in caretaker unit # of offices, lofts & similar sized rooms in caretaker unit Designed for what # roams (list) Three (3) =1 bedroom + 2 future bedr000ms Designed by Gamba & Associates Permit information Mailing Address PO Box 1458, Glenwood Springs, CO 81601 Perc rate 55 Profile hole depth 8 ft Depth to groundwater or bedrock > 8 ft Minimum Septic tank capacity 788 gallons Minimum Absorption area 1169030% reduce=818sf Comments Septic permit approved per compliance with the engineer design and specifications stamped and dated October 4, 2005. Any changes must be approved by this department and the design engineer prior to them being made. Minimum horizontal distances between components of the system and physical features shall conform to the Pitkin County 1SDS regulations. Design is for a 1,00gallon concrete two compartment septic tank with an effluent filter and a dosing chamber. A manifold evenly distributes effluent to a bed designed as 9 units wide by 10 units long of Quick4 gravelless chambers. This department does riot endorse any brand of products. This permit must be kept on-site during installation. The engineer must do a final inspection of the installation and submit an as -built letter to this department. This department must also be called for an inspection with a minimum of 48 hours advanced notice. 'Revegetation over the area of the field is very important for the functioning of the system. Pitkin County has guidelines that must be followed to assure the plants that are introduced are appropriate for the conditions of the area. The use of native plants is strongly Permit approved by: jI Date: stem have been reviewed and are considered sewage disposal s Plans and specifications of the pr osed individual g p y satisfactory. Permission is hereby granted to the owner or the agent to perform the work indicated in accordance with the Pitkin County ISDS Regulation In effect at the time of issue. This permit becomes invalid 6 months from the date that the permit was issued unless system construction has commenced or an extension has been approved in writing by the Department. As -built drawings must be incl ed with this permit before the final approval will be issued. Ci Installer: 1 "'A Final approval: YltLeg,�L Date: 7130 b WIRE FOR LUENT F 2 ALARM. uepu�vanxx nA ��9A rLUIU ]JTIYW+AIW .71ff7�A�. mwc� n . AVG. DOSING RATE =190_gM DOSING VOLUME =133 iiallosnldose! CROSS SECTION OF I,250 -gal 3 -COMPARTMENT FLXX CONCRETE SEPTIC TA] Na to s� 4—in. Sewer Pipe meeting ASTM 3034 spec+rcat'ons, set at minimum slope of 2%, Flow from Dosing Siphon and Distribution Manifo d, one p'pe per each of the NINE (9) rows. ouick4 infi;trator BED: 10 units, (40't) long Fnished Provide Inspection Port, See De as away frc (typ.) Locate Per Plan View,1 j of Inf:ltr -- ---------------------1--------------- ------_-----_ ---- --L---------- 12" (Minimum Cover) 48- (MAXIMUM Cover) i A A fV Pn Ai —r ^ ^ ,fel Engineer and P�ltkln County Strongly Recommeno,placement of , lade mc4slbouider�' just outside of the boundary of the'absorption field ' io keep vehicular' traffic off of field. d ,v. Ol c g� a� 3100' 41 Enniner and Pitkin NUmt\ % l Building Envelope 1 PT1 ` 1 � l 1 �v i]•ISh1bi i rr 1 1 r 1 1 f t 1,250 -gal., 3 -Compartment, \ Concrete Septic Tank Wood Posts PaL�YInc. Innovations in Precast, Drafnage Zabel" & Wastewater Products ADivision atPolyloklna 3 Fairfield Blvd, Wallingford, Connecticut 06492 Off -ice: 1-877-766-9565 Fax: 203-264-8514 email: sales@poly]olc.com Web site: www.potylok.com SmartFittee Alarms 3014A AC -A -0 -SF Mums • Provides audible and visual notihcatian of impending fitter and tank servicing • Patented SmartFilterswitch attaches to all Zabel' Filters • A(arm sounds when tank and filterreach 90% maturity •For mbor/outdooruse Product lnfoimation 055/Pricing 205 Specilicadons Voltage -120 VAC; 5080 Hz, 7 watts max. (alarm cone tton) Alarm enclosure= • 6.&4.50.0 inch (16.51x11.4327.62 Mn), kWb6r-outdo& weathegwW,, thermoplastic meets 3R wafer -tight standards Alarm hom • 62 decibels at 10 feet Alarm beacon Mal& Type 3R water -fight stant:16 s;instalted by factory Tes0flent Switch • CL-Oed to IP66 and IP66 standards switch • SmadRterswitch wtthIS"Cord Warranty for Defects in Material and Workmanship -AC-A-0-SF-3 Years AutoCad R-14 dwg files at wwwzabelzone comIbutocad htm Do Your Part, Be SepticSmart: The Do's and Don'ts of Your Septic System Learn these simple steps to protect your home, health, environment and property value: septicsmart U.S. Environmental Protection Agency Do: • Have your system inspected (in general) every three years by a licensed contractor and have the tank pumped, when necessary, generally every three to five years. Don't: • Pour cooking grease or oil down the sink or toilet. • Rinse coffee grounds into the sink. • Pour household chemicals down the sink or flush them. Don't: • Flush non -degradable products or chemicals, such as feminine hygiene products, condoms, dental floss, diapers, cigarette butts, cat litter, paper towels, pharmaceuticals. Don't: • Park or drive on your drainfield. The weight can damage the drain lines. • Plant trees or shrubs too close to your drainfield, roots can grow into your system and clog it. Don't • Concentrate your water use by using your dishwasher, shower, washing machine, and toilet at the same time. All that extra water can really strain your septic system. Do: • Eliminate or limit the use of a garbage disposal. • Properly dispose of coffee grounds & food. • Put grease in a container to harden before discarding in the trash. Do: • Dispose of these items in the trash can! Do: • Consult a septic service professional to advise you of the proper distance for planting trees and shrubs, depending on your septic tank location. Do: • Stagger the use of water -generating appliances. This can be helpful especially if your system has not been pumped in a long time. • Become more water efficient by fixing plumbing leaks and consider installing bathroom and kitchen faucet aerators and water -efficient products.