Loading...
HomeMy WebLinkAboutpitkin.eh.272929303002 (1974)t� Aug - a93 - 03 - (0 a-- ( ry 2 0 % TKIN COUNTY HEALTH DEPARTMENT W Y � k i !;,V4 14L PERMIT ER RECEIPT NUMBER -� Owner C1 �� Phone #� Owner's Mailing Address Contrac Address Systems Contractor's Name ,,J t %.[' Address-- Legal ddress_Legal Description, Lot Size Type of Building by Use Number of Bedrooms Type of Water Supply Type of Individual Sewage Disposal System. Type of Soil or Soil Classification Proximal Location of Bedrock Proximal Location of Ground Water Table Owner's Signature G Date 7 r PLOT PLAN: fjo( S L — �, i� ♦l O -� Pe 7::ation Test Data Minimum Recommended Absorption System Size es er inch PL i' Minimum Becommended Tank Size PI « A1C C Permit lication valid one year fromate. Application to become permit and final only app after lower portion is completed and signed by t CONSTRUCITON SITE.�-7 Date �U ( / q ;,` `f3anita7 Section COLORADO STATE DEPARTMENT OF PUBLIC HEALTH DIVISION OF SANITATION Code ACTIVITY REPORT FILE REFERENCE: Private Sewage Disposal INDIVIDUAL OR ESTABLISHMENT: Lorraine Sadler 12 County 57 ADDRESS: �- NARRATIVE: I went to final the Sadler system, and found several problems. The Industrial Denver septic tank seemed to be good. The inlet is baffled, and the wall closest to the house slopes away, so the incoming sewage is forced down, and slides to the bottom of the tank. The baffle wall is pre -cast into the tank. The only thing. I question, is that by tapering the wall, the sludge storage capacity is cut, probably by 1/4. The system was not approved. The far end of the bed is actually sitting on grade, rather than being 2 feet into the virgin soil. Ruggles will try to rememdy this with a plastic liner around the low end of the bed. A ditch around the seepage bed, to divert all run-off from it, and give the soil an opportunity to percolate, had not been done. This was a requirement, and must be done before approval is given. LILT TER TO FOLLOW: ( ) OTHER RECOMMENDATIONS: DATE: 1�T} , 19 ES: 7 (8-53-50) REPRESENTATIVE: COLORADO STATE DEPARTMENT OF PUBLIC HEALTH DIVISION OF SANITATION Code 12 Section ACTIVITY REPORT County 57 FILE REFERENCE: INDIVIDUAL OR ESTABLISHMENT ADDRESS: NARRATIVE: I met Lorraine Sadler, Charlie Drew, and Frank, the contractor. First we put 960 dye down the toilet. I was under the understanding that the system consisted only of a holding tank that had never been pumped, which would mean an outfall line either to the river or under the surface of the ground, which would constitute a malfunctioning system. However, we could not substantiate that this was the case. We then went up on the hill to look at her proposed building site. Charlie had an instrument with which we could determine % of slope, and there was an area on the borderline of 30%, somewhat north of where the original soil profile hole had been dug, and may not be in an area of high groundwater. The area is about 90' long and 40-60' wide, and marginally on the 30% slope line. I indicatdd that I would go along with the excavation of another soil profile hole. An application still must be taken out before a percolation test is run. LEITER TO FOLLOW: ( ) OTHER RECOMMENDATIONS: DATE: September 12 1974 REPRESENTATIVE: ES: 7 (8-53-50) J, Section FILE REFERENCE- INDIVIDUAL EFERENCE: INDIVIDUAL OR ESTABLISHMENT ADDRESS: NARRATIVE: COLORADO STATE DEPARTMENT OF PUBLIC HEALTH DIVISION OF SANITATION Code ACTIVITY REPORT County S7 I went to Lorraine Sadler's property to look at the system Jim Ruggles installed. I don't see any way that they can get a diversion ditch above that leach field, because it's too close. He didn't put it in the area that I had specified, and I think Bob was right in turning it down because of the end of the field running into the fill over the old jeep road. They haven't done anything to change it. LETTER TO FOLLOW: ( ) OTHER RECOMMENDATIONS: DATE:19 REPRESENTATIVE: A __ Oc't�l-iar � ES: 7 (8-53-50) ' LORADO DEPARTMENT OF HEALTH DIVISION OF ENGINEERING AND SANITATION A C T I V I T Y R E P O R T Section FILE REFERENCE: Pr&vate sewage disposal INDIVIDUAL OR ESTABLISHMENT: Ron Troxel ADDRESS: Redstone Ranch Acres NARRATIVE: Code 12 County 57 I travelled to Redstone Ranch Acres with Ron Troxel. They have dug a soil profile hole about six or seven feet deep, and found that water was coming in at 4-5 feet because at the time there was water standing 5 feet down from the upper side. The soil looks like a mixture of sand and clay . I would guess the perc rate would be rather flow. There is only one area in which to pOt the system, according to the slope. The rest of the ground is very steep. I told Ron that an engineered system was called for. LETTER TO FOLLOW: ( ) OTHER RECOMMENDATIONS: DATE: _ 5-2g , 19-41�-_ ES: 7 (Rev. 6-70-100) REPRESENTATIVE: r Section FILE REFERENCE: J „JLORADO DEPARTMENT OF HEALTH -? DIVISION OF ENGINEERING AND SANITATION ACT I V I T Y RE PORT Code Ip INDIVIDUAL OR Chuck Lindamoot ESTABLISHMENT: NARRATIVE: County 57 I met Chuck Lindamoo& in Carbondale, and then travelled to the BRB for a site location inspection. Even though the p4& e of ground is less than an acre (specifically .82 acres), it looks reasonable to allow installation of a well and individual sewage disposal system on the property, if the perc tests come out properly. LETTER TO FOLLOW: ( ) OTHER RECOMMENDATIONS: DATE: 4-i8 , 1974 ES: 7 (Rev. 6-70-100) REPRESENTATIVE: COLORADO DEPARTMENT OF HEALTH COUNTY -J-7 REQUEST FOR SERVICE ff PROGRAM /Z RECEIVED BY ii _DATE a Si LOCATION d,<��� % 1 NAME �� REPORTED BY ADDRESS TELEPHONE SERVICE REQUESTED -DI SPOSITI DATE l� SH -M-71 (4-71-50) COLORADO DEPARTMENT OF HEALTH COUNTY REQUEST FOR SERVICE PROGRAM RECEIVED BY DATE LOCATION rr'�xi�. a NAME REPORTED BY ADDRESS TELEPHONE SERVICE REQUESTED wf�i Yui�/r-Yt� ACTION REPORT ��G'�C� — ��`– Gt ✓ ACTION BY /'t` DISPOSITION DATE SH -M-71 (4-71-50)