HomeMy WebLinkAboutpitkin.eh.272929304011 (2008)MEH/NR JNSITE WASTEWATER TREA' ENT SYSTEM (OWTS) CONSTRUCTION PERMIT 0405 Castle Creek Road, Suite 10 - Aspen, CO - 81611 Phone: 970.920.5070 Fax: 970.920.5077 Permit #: 08055 Parcel ID #: 2729-293-04-011 Permit Issued: ❑NEW ®REPAIR ❑REMODEL/ADDITION ®TANK ONLY ❑FIELD ONLY ❑AMENDMENT Owner(s): Eric S. Petterson Property Address: Legal Description Size of Lot: 0.45 Size of Building 0222 Bobcat Lane Lot E-11, Redstone Ranch Acres Acres 954 Sq. Ft. Detached Accessory Unit: DYES ®NO Size of Accessory Unit: The system is designed for: 3 bedrooms Bedrooms 1 &2 upstairs Bedroom in basement Designed By: Gamba & Associates Phone #: 970-945-2550 Fax #: 970-945-1410 Sq. Ft. Proiect #: 08706 Dated: October 8, 2008 Mailing Address: PO Box 1458, Glenwood Springs, CO 81602 Email Address: tcpage@gambaengineering.com Perc Rate: 42 mpi Profile Hole Depth: 12 ft Depth to Groundwater or Bedrock: 212 ft Minimum Tank Capacity: 844 gallons Minimum Absorption Area: 1225 sq ft w/ no reduction Permit Conditions: This OWTS Construction Permit is approved on the condition of compliance with the engineer design as submitted with the application and the specifications cited above. Changes must be approved by this Department and the engineer prior to construction. The existing tank will remain with the addition of an effluent filter. Condition of the tank will be checked and approved by the engineer. An additional pump vault will be installed. Effluent will be pumped to a deep gravel system with a minimum 7.5 feet of 1 %_ " screened rock. 1 foot of % " washed rock will sit above the screened rock in the area the effluent lines will run. The system will have a minimum of 1 foot of native soil for cover. If additional perc tests are conducted and the design is modified, changes must be submitted to this Department, in writing, and approved prior to installation. There must be a minimum setback of 10 feet from any component of the system to the property line, 20 feet from house to the absorption field, and 100 feet from the field to any well. This Permit must be kept on-site during installation. The engineer must do a final inspection of the installation and submit an "as -built" letter to this Department within 30 days of the final inspection, unless a longer period of time has been agreed upon, in writing. This Department must also be called for the final inspection with a minimum of 48 hours notice. Minimum horizontal distances between components of the system and physical features shall conform to the requirements of the Pitkin County OWTS Regulation. This Permit is conditioned upon the property owner(s) providing for regular inspection, cleaning, and maintenance of the system by qualified personnel, in accordance with the manufacturer's recommendations and the requirements of the Pitkin County OWTS Regulation. THIS PERMIT IS EXPRESSLY CONDITIONED UPON COMPLIANCE WITH ALL REQUIREMENTS OF THE PITKIN COUNTY OWTS REGULATION, INCLUDING BUT NOT LIMITED TO THOSE CONDITIONS SPECIFIED ABOVE. Plans and specifications for the proposed OWTS have been reviewed and are considered satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated in accordance with the Pitkin County OWTS Regulation. This Permit will expire 1 year from the date of issuance unless construction on the system has commenced. An "as -built" drawing must be submitted and approved by EH/NR before final approval of the system will be issued. Issued By: u-ar( (-r OV &&)-L Date: %Q(0 _09 Expires: Installer: VI f - ( �" nse#: '')0% Reactivation Authorized by: Final Approval Issued By: � (� �C Date: (t I ( V) New Expiration Date: Fee Fwfd ONSITE WASTEWATER TREATM" IT SYSTEM (OWTS) =EH/NR CONSTRUCTION PERMIT APPLICATION 0405 Castle Creek Road, Suite 10 • Aspen, CO • 81611 Phone: 970.920.5070 Fax: 970.920.5077 Parcel ID# (available from the Pitkin County Assessor's Office 970-920-5160 or at www.pitkinassessor.org : 2729 - 293 -04 -011 Purpose of Permit: ❑ NEW � REPAIR DUE TO FAILURE ❑ REMODEL/ADDITION ❑TANK ONLY ❑✓ FIELD ONLY Cost of System Repair or Remodel/Addition (approximate): City, State, Zip: Redstone, Colorado 81623-9941 Property Address: 0222 Bobcat Lane, Redstone, Colorado 81623-9941 Business Phone: Lot: Block: Filing: E-11 Subdivision: Redstone Ranch Acres Property Owner(s)': Email Address: Eric S. Petterson eric.petterson@starband.net Owner's Mailing Address: 0222 Bobcat Lane, City, State, Zip: Redstone, Colorado 81623-9941 Home Phone: Business Phone: (970) 704-1226 (970) 963-2190 `Contact information must be provided for the owner signing this application Primary Contact Person/Applicant (if not owner): T. Carter Page, P.E. Company: Gamba & Associates, Inc. Contact/Applicant Mailing Address: P.O. Box 1458, 113 9th Street, Suite 214 City, State, Zip: Glenwood Springs, CO 81601 Cell Phone: (970) 948-3149 Business Phone: (970) 945-2550 Extension 206 Fax Number: Email Address: (970)945-1410 tcpage@gambaengineering.com Building Permit # (if applicable): Not Applicable Lot Size (in acres): 0.45 Acres Size of Building (square feet): Number of Potential Bedrooms: 954 square feet TwaEm r1t PE -E (3) Detached Accessory Unit? Size of Accessory Unit (square feet): [3YES ONO Not Applicable Number of Potential Bedrooms In or Fixture List for the Accessory Unit: Not Applicable Water Source: [D PRIVATE WELL ❑ SURFACE WATER ❑ SPRING ❑ COMMUNITY/PUBLIC WATER SYSTEM Name of Community/Public Water System (if applicable): Not Applicable EngineeringFirm: Job Number: Phone Number: Fax Number: GambaAssociates, Inc. 08706 (970) 945-2550 Ext. 206 (970) 945-1410 MailingAddress: City, State, Zip: P.O.ox 1458, 113 9th Street, Suite 214 Glenwood Springs, CO 81601 PLEASE READ BEFORE SIGNING: I certify that the above information is complete and accurate and that I have provided complete and accurate information in all of the documents included in my application package. I acknowledge that EH/NR may revoke any permit I am issued if my application is found to contain any inaccurate, false, or misleading information. I understand that no construction may be undertaken on an OWTS until an OWTS Construction Permit is issued. Owner Signatures Date: / — ( "Ov Applicant Signat�ur . / Date: September 30, 2008 Fee & Receipt #: Date: )a-.�i e 10 9 0 1 D I g I G A M B A & A 5 5 0 C I A T E 5 CONSULTING ENGINEERS & LAND SURVEYORS PHONE: 970/945-2550 FAX: 970/945-1410 Tuesday, June 2�', 2009 Carla Ostberg Pitkin County Environmental Health and Natural Resources Schultz Health and Human Services Building 4050 Castle Creek Road, Suite 10 Aspen, CO 81611 Original by mail, copy by email to: carlabCcDco.pitkin.co.us RE: Petterson field replacement — Final approval letter, OWTS for Pitkin County Permit Number: 08055 Dear Carla: This letter is being sent to inform you that the last item on our list for the approval of the system, the pumping of the septic tank, has been accomplished, and documented by the owner in the form of photographs provided to Gamba & Associates, Inc. as well as Pitkin County. The field has been installed in substantial compliance with our design drawings, as has the effluent pump and chamber. No significant changes to the design drawings have been made, and we do not believe that separate "as -built" pians are warranted. The original design plans accurately show the location of the septic tank, effluent pump chamber, and absorption field. There is one concern which should be monitored by the owner, and that is the condition of the natural slope to the northeast of the absorption field. This area should be monitored regularly, and any sign of unusual seepage should be immediately reported. While we have not yet been on-site to view the condition of the absorption field during the high run-off period currently underway, we will be able to make a site visit this week. We will keep you informed as to what we find. If you have any questions, please call me at (970) 945-2550 extension 206, or email me at tcpageCa-Dgambaengineering.com. Sincerely, Gamba & Assoc •�s4tTESK'/�,fl 111111AMIUM 113 NINTH STREET. SUITE 214 Petterson OV,/TS — Final System approval. P.O. BOX 1458 GLENWOOD SPRINGS, Tuesday, June 2"d, 2009 COLORADO 81602-14 58 Page 1 of 1 ISDS DESIGN CALCULATIONS - for Pitkin Owner's Name Parcel ID # �*!AWMW House Size (sq. ft.) (75 gpd or 100 gpd) 75V Number of Bedrooms in Main House Number of Offices, Libraries, Studies, Similar -sized Rooms in Main House EWA M1 Number of Bedrooms in Detached Caretaker unit Number of Offices, Studies, Similar -sized Rooms in Caretaker Unit (If the caretaker unit is ATTACHED, treat as if part of main house.) Average Daily Waste Flow 450 State Review Required? no Perc Rate +5MTLV ('1) Design Flow (Q) = # potential bedrooms X 2 people/bedroom X gpd X 1.5 Q= 675 Minimum tank capacity 844 gallons Absorption Area (=Q/5 X SQRT perc rate)(1.4 loading factor) A = 1,225 sq. ft. of absorption area required Absorption Area (=Q/5 X SQRT perc rate) WITH SECONDARY TREATMENT (no loading factor) A= 875 sq. ft. of absorption area required Abs. Area w/ loading factor (B25) Trench Bed Quick4 Trench Quick4 Bed Pipe and Gravel (-10%) 1102 no red. 1225 112 124 Dosing (-20%) 980 (-20%) 980 99 99 Chambers (-30%) 857 (-10%) 1102 87 112 Max Allowable -50% 612 (-30%) 857 62 87 Secondary Treatment Abs Area w/ out loading factor (B28) Trench Bed Pipe and Gravel (-10%) 787 no red. 875 80 89 Dosing (-20%) 700 (-20%) 700 71 71 Chambers (-30%) 612(-10%) 787 62 SO Max Allowable (-50%) 437 (-30%) 612 44 62 100 SETBACK FROM WELL # of feet = 50 SETBACK FROM POND, STREAM OR IRRIGATION DITCH # of feet = 25 SETBACK FROM DRY GULCH # of feet = vs FROST -FREE CAST IRON use S Effluent Force Main use Scn. 40 -PVC OR SDR -9 FRAME AND COVER HDPE Attach 12 -WAC, "UF" insulated trace wire. Effluent Discharge to MINIMUM SLCPE: 2% Distribution Manifold and Absorption field. GRAVITY SEWERr Orono Systems FROM SECOND OSI Sewage Effluent Pump: PEF-5011 MPARTMENT OF SEPTIC TANK. 48.4-gpm, }-Hp, 11OVAC. BOHz Float Assembly; MF3A-Y.B.R-51FS-10 CO Control Panel: MVP -S -I -HT Plan View - Proposed Effluent Pump Vault N. W Late ------------ ------ GRAVITY SEWER 2.0' (min.) - FROM SECOND COVER COMPARTMENT OF SEPTIC TANK. I MINIMUM SLOPE: 2R NOTE: Float Support Pipe should extend from within 3 -inches of inside of access lid, to the floor of the Pump Vault. Float levels for Pump On, Pump Off and Alarm conditions will be set in the field. Design pumping volume is approximately 300 -gallons. Minimum height of water (Pump Off) level must be 5 -inches above Pump Intake. Pump shall be set off the floor of the Pump Vault at least B -inches. Oren Systems : 1 1 48" (min.) OSI Sewage Effluent Pump: PEF-5011 (NO JOINTS) 48.4-gpm, tHp, IIOVAC, 80Hi Float Assembly: M Y,B,R-51F5-10 Central Panel: MVP -S -I -HT 48" (min.) 0.50' Pump Bottom FROST -FREE CAST IRON FRAME AND COVER PRE -CAST REINFORCED CONCRETE MANHOLE BARREL 1} -In. Effluent Force Main use Son. 40 -PVC OR SDR -9 5.0' (min.) HOPE Attach 12 -WAG, "UF - COVER insulated trace wire. Effluent Discharge to Distribution Manifold and Absorption field. MANHOLE JOINTS TO BE SEALED WITH 'Rub'R-Nek' MANUFACTURED BY K.T. SNYDER COMPANY DR APPROVED EQUAL RUBBER 0 -RING GASKETS MAY BE USED IF APPROVED BY THE ENGINEER. BOTTOM SECTION OF MANHOLE/PUMP CHAMBER SHALL HAVE NO JOINTS TO A HEIGHT OF 4-k. (min.) COMPACTED SCREENED ROCK BEDDING, OVER COMPACTED NATIVE SOILS. Profile View - Proposed Effluent Pumn Vault \« ,' S"I, Revised Pump Chamber & Pipe Eric Petterson Details 0222 Hob"` Line Kedatone, CO 61623-9941 Ow rrrrn 704-1220 SCALE: Not to Scale D4, E. No"o6t11,20M DR;':.':3": -P SHEET:Ioi ��o:Ecr.oB706 c-rDs*. GAMBA & ASSOCIATES, INC. CONSULTING [NOINf ZitS A LAND SURVBiYORS Ike Details -3 Bedroom-i1V20061112Avii G A M B A 1s7"4B-2380 WWW.GAMBASNGINKZNING.COM OIRECTORv H:%037051 m A S e o C I A T e • 112 wTIMI er. eTL a14 V^ —1 lobe eL�IwOOw srolMae. —.1001 17J NOTES ON DISTRIBUTION PIPING: 1) Use smallest size Hole Saw to drill hole in 4—inch Diameter Inspection Port Pipe, to allow passage of 1j7inch Sch. 40 P.V.C. END CAP. 2) Drill A—inch holes of the 5 o'clock and 7 o'clock positions, alternating positions, on 2.5—foot centers along length of each Perforated Distribution Pipe. 3) Begin 33—in. holes 2—ft. INSIDE edge of the Adsorption Field Boundary. 4) Each Perforated Distribution Pipe is to start at the Distribution Manifold, and extend to within 2—feet of the end of the Absorption Bed. 5) Distribution Pipes are to be set starting 4—feet in from the Eastern Edge of the absorption field, and on 4—foot centers thereafter. TWO (2) Perforated Distribution Pipes are required. Each perforated Distribution Pipe is to be variable in length, see Sheet #1. 6) DO NOT bury any portion of the Perforated Distribution Piping until inspected and approved by the Engineer. 1}—Inch Sch. 40 P.V.C. Distribution Pipe — WITH END Inspection Ports — present at the CAP. ends of ALL Perforated Distribution Pipes. 1i—inch Dia.. Perforated Separation Fabric: Mirafi 60OX Distribution Pipes to be set l used. LEVEL to within t 0.05—feet. 1\P2fX/ � NO OTHER MATERIAL to or be used. From Distribution Manifold (typ / Perforated Distribution Pipes to be centered in \_ ,h—in. Hole, drilled ® 6 o'clock 12—inch thick bed of J—inch WASHED GRAVEL. position in End Cap. PERFORATED DISTRIBUTION PIPING END DETAILS Not to Stale Revised Perforated Pipe Eric Petterson Sob"t Lam Details Red3toae?CoIB G23-994 MMI 704.1220 KALE: NolNkok -- Noresba 11,2008 DRAWN 8v: kp SHEET:2e1 ?c .EC:0S706 CHKDBY: GAMBA & ASSOCIATES, INC. GONSYLTINO KNOINitss • LANp sunyRTORe DRAWING: INI! Oetiw • I ledleea-KY 2008111Ldr9 G A M BA �.WO 1NISM OAMSAO1i1N818SSIMLCOM DIRECTORY: NA0870N • A M Z O C I A T E ■ I.> 111MeM A met. �u PUIL�"111O OLwOr BOOR MNM� r 2.00' Install: (tYp) ONE (1) ELBOW EACH SIDE 1i—in. Distribution Pipe. .r« Perforations start over absorption field. Extend to 5—ft. (min.) Vertical Pipe RiserBelow Finished _r'9 Ground from Pump Vault Distribution Manifold: MUST be set level on 6—in. thick bed of consolidated Pea Gravel. SECTION VIEW - DISTRIBUTION MANIFOLD DETAILS Not to Scale NOTE: The Distribution Mc MUST be set level across i length, on a 6—in. thick b consolidated Pea Grovel. Vertical Pipe Riser from Pump Vault 1i—in. Sch. 40 PVC Discharge Manifold 1i -in. 90' ELB (tYp•) ft. all: ELBOW SIDE PLAN VIEW - DISTRIBUTION MANIFOLD DETAILS Not to Scale Revised Manifold Eric Petterson 0222 Bobcat Line Details Rcd3tone, C06IG23-9941 070) 70.1226 SCALE: Not to kala November 11, 7008 DRAWN BY: kp SHEET:3of �RD-ECT.03706 CHKDBY: GAMBA & ASSOCIATES, INC. CONSULTING KNGIN[[RS • LAND SURV[YORS DRAWING: field Details -3 Bedr"a-RIV20081112.d" G A M B A 970/943-2330 WWW.GAMBASHORMSKRINCI.COM DIRECTORY: 11•:,087061. a, A • • o C r A T e s ++f NINTH W.. a l+• _ WX +aN e�nnreoe oa etNeu. CA e+aoa Pitkin Country Environmental Health Department Contact Log Sheet RMI R -A ,- - Pitkin County Environmental Health Department Contact Log Sheet -2- ,7 a Carla Ostberg From: Carter Page [tcpage@gambaengineering.com] Sent: Wednesday, November 12, 2008 12:29 PM To: Carla Ostberg Subject: Petterson OWTS - Status Attachments: Revised Field and Pump Details.pdf Carla Eric has the bottom gravel set for the field, also the effluent pump tank. They are waiting for the pump and floats, controls, etc. We changed the pump, and also the piping size and the spacing of the perforations. This was due to a recommendation from the pump supplier, who is very Orenco knowledgeable, that the pump I selected was not the best type for this particular application. I pay attention when these guys talk, as I do not pretend to know everything there is to know about pumps! I have sent revised drawings to Eric, who will get them to Duane Piffer. I am copying you with the same drawings, so you know what is happening. If we can get the pump and controls soon, I do not expect a problem getting the system installed on-time. If the pump and controls do not arrive, we may be late. This would be my fault, because I could not immediately respond to the pump change recommendation. Eric will be sending me some photos shortly, and I will forward them on to you, so you can see the status of the system. Carter T. Carter Page, P.E. Gamba & Associates, Inc. P.O. Box 1458 113 9th Street, Suite 214 Glenwood Springs, CO 81601 Phone: (970) 945-2550 ext. 106 FAX: (970) 945-1410 Cell: (970) 948-3149 email: tcpageAgambaen ink eering.com Single Family Home - Redstorlp.,CO, 81623 - Realtor.com Af Page 1 of 2 Get a sneak peek at the new REALTOR.com® beta. Check it out. t"Twumm OfficialSite of the Nati 113Nationnal Association of REALTORS i n d i n I Feedback Back to Search Results Listing Details Map & Directions $575,000 3 Bed, 2 Bath 0.45 Acres Estimated Payment: $3,194 Per Month* Change Assumptions Check Local Mortgage Rates Single Family Property, Area: 08CV-Crystal Valley, County: Pitkin, Approximately 0.45 acre(s), Year Built: 1999, View, Two story, Basement, Laundry room This listing is brokered by: Mason & Morse Real Estate Office(970)963-1061 4 Prev 29 of 284 Listings Next Redstone, CO 81623 MLS ID# 106022 ® Send to a REALTORa ® Send to a Friend M+ Save this Listing Property Features ' Single Family Property 2 total full bath(s) Heating features: Propane • Status: Active Two story Interior features: Basement, ' Area: 08CV-Crystal Valley Living room Clothes dryer, Clothes washer, ' County: Pitkin Family room Dishwasher, Formal living rm, ' Year Built: 1999 Basement Laundry rm/area, Range and • 3 total bedroom(s) Laundry room oven, Refrigerator, Utility rm ' 2 total bath(s) Exterior features: Fenced, Satellite dish, Scenic view, Septic sewer system, Storage/out- building(s), Trees, Water supply from well(s) ' View • Approximately 0.45 acre(s) ' Lot size is less than 1/2 acre Helping you Move... Finance Your Home Move Settle In Get your Credit Report/ Score before Moving Checklist Insurance Quotes by State Farm getting a mortgage. Rent a Truck Learn how to Green Your Home Save with No Fee Mortgage PLUS Free Storage Quotes Get 3 Free Home Improvement Bids Save over $1000 on Mortgage htti)://www.realtor.comlsearchllistingdetail.aspx?ctid=91273&bd=4&bth=4&typ=1 &sid=4... 8/27/2008 Kristen Stroud From: Carter Page [tcpage@gambaengineering.com] Sent: Thursday, November 06, 2008 9:51 AM To: I Subject: 08706; Petterson OWTS status Carla I made a site visit yesterday to observe the excavation for the absorption field at the Petterson site, 222 Bobcat Lane, Redstone. I noted the following: 1. The excavation is 8 -feet plus deep, and bottom appears fairly level. a. This will provide for 7.5 -feet of screened rock below the distribution bed. b. The top of the distribution bed will be at, or slightly above native ground level. c. This will allow for mounding over the field, which will help prevent people from driving on top of the field. 2. The excavation has fairly straight sidewalls on the south-west, east and north-east sides. (Road side, adjoining lot side and side toward creek, respectively). 3. The north-west side is rough, and sloping, due to the older field that they encountered. 4. The excavation is too close to the property line on the south-west side, parallel to the road. a. I advised Eric, who is to advise Duane, that this needs to be brought back to the 10 -foot property line setback as shown on the plans. This shall be done with native soils, compacted to at least 90%. b. This must be inspected as it happens. 5. The excavation is a little closer to the steep edge going down to the stream on the north-east side. I am considering options here, to prevent the softening of the slope, and emergence of effluent on the slope. 6. 1 will keep all advised as to the approach to take on this side. 7. 1 have advised Eric that a roughly rectangular field, 13 -feet wide and 50 -feet long, is the basis of the calculation. 8. Larger than this is O.K., so long as we do not intrude into the 100 -foot well offset, or crowd the 10 -foot property line offsets, or the steep slope on the north-east. 9. There must be at least 4 -feet of compacted native soils placed between the new field and the existing field. This soil separation must extend all the way down to the bottom of the new absorption field, and possibly beyond, if the existing field is deeper than the new field. 10. 1 did not perform any additional percolation tests, the ground was totally saturated with rain and snow. Eric had prepared two additional percolation test holes, but they were "slushy" and I did not believe we would get a markedly different percolation rate than what is designed for, since this is the level at which we took a soil sample, and had the gradation and hydrometry tests run. 11. 1 have sent some photos separately. 12. Eric will not begin placing gravel until I can resolve my concerns about the north-east face of the excavation, where it is close to the slope down to the creek. Thanks, Carter T. Carter Page, P.E. Gamba & Associates, Inc. P.O. Box 1458 113 9th Street, Suite 214 Glenwood Springs, CO 81601 Phone: (970) 945-2550 ext. 106 FAX: (970) 945-1410 Cell: (970) 948-3149 email: tcpage( gambaen inneering com r4_i Kristen Stroud From: Carter Page [tcpage@gambaengineering.com] Sent: Thursday, November 06, 2008 9:50 AM To: Carla Ostberg; Eric Petterson Subject: 08706; Petterson OWTS photos Attachments: PB050007.JPG; PB050008.JPG-, PB050009.JPG; PB050010.JPG; PB050011.JPG Carla: Next group of photos from Petterson site. Photos show: -003 Looking at excavation from road, looking at north-east wall (in distance, by shed). -004 Looking south-easterly, the aspen tree in the view is roughly the property line. Excavation comes to within 3 -feet of this tree. -005 Looking at the sloping north-west wall. -006 Looking at the sloping north-west wall. -007 Looking at the south-east wall, which is parallel to the road. -008 In the excavation, looking to the south-east, Ted Kerns (G&A inspector) is standing on the north-west slope. -009 A view of the north-west wall, some of the gravel from the older field is visible. -010 A view of the north-west wall, some of the gravel from the older field is visible. -011 Looking down into the excavation, from beside the shed at the north-east end. A percolation test hole is visible (one of two). Carter T. Carter Page, P.E. Gamba & Associates, Inc. P.O. Box 1458 113 9th Street, Suite 214 Glenwood Springs, CO 81601 Phone: (970) 945-2550 ext. 106 FAX: (970) 945-1410 Cell: (970) 948-3149 email: tcpageggambaen ing eering.com Kristen Stroud From: Carter Page [tcpage@gambaengineering.com] Sent: Thursday, November 06, 2008 9:47 AM To: Carla Ostberg; Eric Petterson Subject: 08706; Petterson OWTS Attachments: PB050005.JPG; PB050006.JPG-, PB050003.JPG-, PB050004.JPG Carla: I tried to send the email with photos, but it was sent back. Trying again, with first four photos only. Photos show: -003 Looking at excavation from road, looking at north-east wall (in distance, by shed). -004 Looking south-easterly, the aspen tree in the view is roughly the property line. Excavation comes to within 3 -feet of this tree. -005 Looking at the sloping north-west wall. -006 Looking at the sloping north-west wall. -007 Looking at the south-east wall, which is parallel to the road. -008 In the excavation, looking to the south-east, Ted Kerns (G&A inspector) is standing on the north-west slope. -009 A view of the north-west wall, some of the gravel from the older field is visible. -010 A view of the north-west wall, some of the gravel from the older field is visible. -011 Looking down into the excavation, from beside the shed at the north-east end. A percolation test hole is visible (one of two). Carter T. Carter Page, P.E. Gamba & Associates, Inc. P.O. Box 1458 113 9th Street, Suite 214 Glenwood Springs, CO 81601 Phone: (970) 945-2550 ext. 106 FAX: (970) 945-1410 Cell: (970) 948-3149 email: tcpagekgambaengineerinu�.com Carla Ostberg From: Carter Page [tcpage@gambaengineering.com] Sent: Friday, October 31, 2008 11:13 AM To: Carla Ostberg Cc: Eric Petterson Subject: RE: Petterson OWTS - status Carla I spoke with Duane Piffer yesterday, and he has ordered most of the parts needed for the system. I am speaking with the supplier to see if there is a better (longer lasting) pump that we might substitute. There could possibly be some changes in the number, spacing, and size of holes in the perforated pipe. I will keep you informed. Duane plans to be digging by early next week. He thinks that the basic excavation may be ready by Wednesday. Carter From: Carla Ostberg [mailto:Carla.Ostberg@co.pitkin.co.us] Sent: Friday, October 31, 2008 11:11 AM To: Carter Page Subject: RE: Petterson OWTS - status OK — thank you for the update! Carla Ostberg, REHS Environmental Health Program Supervisor Pitkin County Environmental Health and Natural Resources 970-920-5438 From: Carter Page [mailto:tcpage@gambaengineering.com] Sent: Wednesday, October 29, 2008 9:44 AM To: Carla Ostberg Cc: Eric Petterson Subject: Petterson OWTS - status Carla: I called Eric to see what the status of the project was, and he informed me that Duane Piffer is bringing in some equipment today, Wednesday the 29`h He said that Duane will start the excavation on Monday, November 3`d. Eric is also having B&R septic pump his tank out, on Monday, so that I can measure the inside, and confirm the dimensions. If the specified Polylok effluent filter arrives by Monday, or even Tuesday, then it will be pretty simple to install the filter in the tank, if it is largely empty. I would hope that Duane can get the whole field excavated in time, so that the septic tank does not fill before the field is fully installed and ready to be put in use. If the tank fills before that, it will need to be pumped again, so that effluent is not just draining into the ground out of an open pipe. Carter T. Carter Page, P.E. Gamba & Associates, Inc. P.O. Box 1458 113 9th Street, Suite 214 Glenwood Springs, CO 81601 Phone: (970) 945-2550 ext. 106 T "4c Vk'f IA I j� - F t y ♦ � � ` I+ � �� tp' . ✓ -�"_fir /"!� ,� rOwl low E` _e e,y• R At ta .. w. 00 +���1 A r M / •i I•t ,' r * f - w r � 060 A i *P yy *P !I let *moo jo —jr Carla Ostber From: Eric Petterson [epetterson@rmes-inc.com] Sent: Friday, April 24, 2009 7:15 AM To: Carla Ostberg Cc: 'Carter Page' Subject: 222 bobcat lane septic Attachments: water-side.jpg; solids-side.JPG; water-side2.JPG Carla- per your request, we had the septic tank pumped out last week (the snow finally melted out). Here are some photos showing the solids side and the water side with the new pre -treat filter. The snow is still hanging in there on the leachfield, but as soon as it comes off I'll seed and mulch it (I already have the seed purchased). Let me know if you need anything else. Thank you Eric Petterson Rocky Mountain Ecological Services, Inc. phone/fax: 970-963-2190 mobile: 970-309-4454 epetterson()rmes-inc.com www.rmes-inc.com 1 _71M %V r.j � : "J eP¢Iml. � , G 4 b = Carla Ostberg From: Tony Fusaro Sent: Wednesday, October 08, 2008 12:11 PM To: Carla Ostberg Cc: Rose Ann Sullivan; Carrington Brown Subject: RE: Petterson Carla, I do not have a Notice of Non -Compliance against Eric, so there is no problem taking in or issuing the OWTS permit. He has informed me of his progress in legalizing the basement, and I am happy with that. I won't issue a notice to him unless he fails to continue reasonable progress, and getting his OWTS compliant is part of that, so let's keep prodding him to get this mess straightened out. Tony From: Carla Ostberg Sent: Wednesday, October 08, 2008 11:36 AM To: Tony Fusaro Cc: Rose Ann Sullivan; Carrington Brown Subject: Petterson Hi Tony, I am going to take in an application for an OWTS today for the Petterson property and the engineer has sized the system to accommodate 3 bedrooms. If you still have a red tag on the residence, I understand that I cannot ISSUE the permit. I spoke with Eric the other day and he is trying to time the system replacement with his family going away given the fact that there will be a short time they won't be able to use the system and the safety issues associated with large equipment and having small children around. In any case, does Eric know that the red tag needs to be lifted in order for us to issue the permit? Does he know what he needs to do in order to have it lifted. I did not discuss that with him the other day, so I'm not sure it's on his radar. Thanks, Carla Ostberg, REHS Environmental Health Program Supervisor Pitkin County Environmental Health and Natural Resources 970-920-5438 Pitkin. 4unty- October 6, 2008 Eric S. Petterson 222 Bobcat Lane Redstone, CO 81623 ___ --.-&enW Health & Natural Resources Re: Continuing Violation - Noncompliant and Failed Onsite Wastewater Treatment System ("OWTS") Dear Mr. Petterson: Reference is made to the Notice of Violation issued by the Pitkin County Code Enforcement Officer on June 9, 2008 and the follow-up letter issued by the Pitkinr County Code Enforcement Officer on August 27, 2008. It was the expectation of this Department that a complete OWTS Construction Permit application would be submitted by September 15, 2008. As you know, a new OWTS Construction Permit is required to authorize repair of the failed system on the property. We have not received any application for repair of the current system, which we also understand is improperly sized, as it is serving an additional bedroom in the basement of the residence. The basement was finished without a Pitkin County Building Permit. We have provided you with a reasonable amount of time to address the OWTS issue on your property The approaching winter months now necessitate that immediate action be taken. The purpose of this letter is to advise you that, pursuant to Sec. 6.28.170(E) of the County"s OWTS Regulation, we are taking steps to schedule a hearing with the County's Health Officer to obtain a cease and desist order for use of the OWTS on the property on the grounds that it is: (i) not in compliance with the Individual Sewage Disposal System Permit previously issued for the property, (ii) not functioning in compliance with the County's OWTS Regulation, and (iii) constitutes a hazard to public health and the environment. We will also be discussing whether or not to seek the assessment of monetary penalties at this hearing due to the length of time this violation has continued unabated, See OWTS Regulation Secs 6.28.170(E)(3) and (F)(2). We strongly encourage you to devote your full attention to the resolution of this issue within the next week. Please feel free to contact me directly if you have any questions,about our regulatory process. It is our hope that we will still be able to resolve this matter in an amicable fashion. Sincerely, ( a : Carla Ostberg, RENS Environmental Health Program Supervisor Ccs: Carrington Brown Tony Fusaro T. Carter Page 0405 Castle Creek Road, Suite 10 Aspen, Colorado S 161 1 (970) 920-5070 fax (970) 920-5077 www.aspenpitkin.com/ehnr l; 9FI C PITKIN COUNTY CODE ENFORCEMENT Courthouse Annex Building 530 East Main Street, Suite 302 Aspen, Colorado 81611 970-429-2814/970-379-6872 8/27/08 Mr. Eric Petterson 222 Bobcat Lane Redstone, Co 81623 Dear Mr. Petterson, I am writing you regarding the status of the Notice of Violation I issued you on June 9, 2008 for your property located at 222 Bobcat Lane, Pitkin County. I understand that you have cured some of the Notice by moving the yard fence onto your property, removing one illegal shed and you have applied for permits for the two remaining sheds. I also understand that you have been communicating with Nancy MacKenzie of Pitkin County Environmental Health and Natural Resources regarding the status of the septic field. I understand that Mrs. MacKenzie required that you remove the earth over the manifold system for inspection. I recall that you told me you were reluctant to do this and Mrs. McKenzie then suggested that you have the manifold inspected via in -pipe video. To date neither of these inspections has taken place as you have not taken the necessary steps. I have been recently informed that you have hired Mr. Carter Page of Gamba & Associates, Inc. to design a new septic field because, according to what Mr. Page tells us, the current septic field is allegedly in unsatisfactory condition (crushed manifold pipes and gravelless chambers) and will not pass the Pitkin County inspection. Unless otherwise concluded via inspection we consider this septic field to be a "failed system" that needs immediate replacement. Your hiring an engineer to design a new septic field supports this conclusion. Having an engineer design a new septic field is an appropriate first step towards replacing the field. However, in order for the County to issue a permit for the new septic field we must know how many bedrooms and bathrooms are in the house. The house originally received its C.O. with 2 bedrooms, one bathroom and an unfinished basement. I now understand that there is a possibility that the basement has been finished and that it now contains a bedroom and a bathroom, bringing the total for the house to 3 bedrooms and 2 bathrooms. This possibility is supported by the fact that the house is currently listed for sale by Mason and Morse as having 3 bedrooms and 2 bathrooms. In this case, the new septic field needs to be designed to accommodate these additions. In order for the County to process your pending septic permit, we will need to verify, via inspection, how many bedrooms and bathrooms are in the house. If we find that the "unfinished" basement has been finished you will be required to apply for and obtain building permits for work performed. As part of that process you have two options for the inspections related to issuing those building permits: 1) obtain notarized affidavits from a Colorado State licensed carpenter, plumber and electrician attesting that the work was performed to all pertinent Building Code standard and from a state licensed engineer if structural changes were made, or 2) remove sufficient dry wall so County inspectors can view/inspect the piping, electrical and framing of the areas finished/installed without permits. You may make this decision with County Building Department staff. In summary, in order for you to conclude curing the Notice of Violation against this property please do the following: 1) Replace the failed septic system: a) Apply for and obtain a Pitkin County septic permit for a septic system designed to accommodate the number of bathrooms and bedrooms currently in the house. b) The septic permit process includes an inspection of the house by County staff to establish the number of bedrooms and bathrooms. Please keep in mind that if your lot will not accommodate a septic field of sufficient size for the number of bedrooms and bathrooms currently in the house you will be required to reduce the number of bedrooms and bathrooms to the number originally present when the house received its C.O. 2) The failed septic system must be replaced and successfully inspected by Pitkin County no later than October 30'h, 2008. In order to accomplish this please submit your complete septic application, based on a professionally produced design, to Pitkin County Environmental Health and Natural Resources by September 15'h, 2008. Arrange for the house inspection establishing the number of bedrooms and bathrooms to be completed by September 15, 2008. 3) Submit for and obtain building permits for the work done in the originally unfinished basement area by October 30, 2008. 4) Conclude obtaining permits for the two sheds by September 15'h, 2008. Please be advised that if the new septic location/size will not accommodate one or either of these sheds the shed in question will need to be moved to another location and subject to permits for that new location. Mr. Peterson, we appreciate your efforts to date to remedy the code violations on your property. I look forward to your completing the cure of the Notice of Violation according to the dates given above and if you have questions about how to do so, please contact me at 429-2814. Your contact in Environmental Health and Natural Resources is Carla Ostberg at 920-5438 and your contact in the County Building Department is Tony Fusaro at 920-5101. Sincerely, Carrington Brown Pitkin County Code Enforcement Cc: John Ely, Pitkin County Attorney Tony Fusaro, Pitkin County Building Department Joanna Schaffner, Pitkin County Zoning Officer Carla Ostberg, Pitkin County Environmental Health and Natural Resources Lance Clark, Pitkin County Community Development G A M B A & ASSOCIATES CONSULTING ENGINEERS & LAND SURVEYORS PHONE: 970/945-2550 FAX: 970/945-1410 113 NINTH STREET, SUITE 214 P.O. Box 1458 GLENWOOD SPRINGS, COLORADO 81602-1458 Wednesday, October 8'f', 2008 Carla Ostberg Pitkin County Environmental Health and Natural Resources Schultz Health and Human Services Building 4050 Castle Creek Road, Suite 10 Aspen, CO 81611 RE: Petterson field replacement — OWTS pre -application meeting. Dear Carla: This letter is an addendum to the Onsite Wastewater Treatment Systems application for the Eric Petterson home at 0222 Bobcat Lane, Redstone, Colorado. As you may be aware, there is an existing OWTS system in place on the property. According to the previous permit issued, and the "as -built" drawing provided, the existing system consists of a 1,000 -gallon concrete septic tank (two compartments) and a 30 -unit Infiltrator (Quick4??) field. The system was permitted and installed under the previous owner, Glen Harsh. Apparently, the previous owner had not delineated the area of the absorption field, and parking occurred over the field. As a result, some of the Infiltrator chambers were crushed. Some time after Eric Petterson purchased the property, problems with the OWTS began to appear. Excavation(s) in the area of the absorption field revealed the crushed chambers. Some quantity of washed gravel was placed in the area of the crushed chambers as a repair measure or as a makeshift drywell. No permit was obtained for this work. We were hired by Eric Petterson to repair the absorption field and bring the system into compliance with Pitkin County regulations. Accordingly, a new profile hole, and three percolation test holes were excavated, on September 151, 2008. We made a site visit the following day, after the percolation test holes had been soaked, and observed the profile hole conditions, and conducted percolation testing. We observed the excavation and noted the following: 1. There was no observed water, nor any sign of mottling, to a depth of 8 - feet below existing ground. 2. There was no observed bedrock or large boulders to a depth of 8 -feet below existing ground. 3. The soil in the profile hole was fairly uniform in color and appearance from the ground to the bottom. The soil was generally wet -appearing, due to recent rains. 4. There were small rocks and cobble exposed on the walls and bottom of the profile hole. 5. Color was mostly dark brown, with some areas of reddish soil and rock. Petterson OWTS — addendum to the Permit Submittal. Wednesday, October 8'h, 2008 Page 1 of 4 6. A 4 -inch diameter perforated SDR -35 pipe was set in the profile hole. We believe that the perforated pipe will provide an easy way to confirm that there is no water present to a depth of 8 -feet below existing ground. The pipe is still in place, and will be visible in the area staked for the absorption field. Three new percolation test hole were also dug, unfortunately, portions of the existing Infiltrator chamber bed system were encountered, and the percolation test holes may have also encountered some of the gravel previously placed. Results of the percolation test were highly variable. Test hole number 1, at the southern end of the proposed field, would not hold water, regardless of the volume discharged from the garden hose, or the time that it was left running. During the active measuring phase of the percolation rates for the other two holes, a garden hose was left in hole number 1, running with a fully open hose bib. Percolation hole number 1 never held any appreciable volume of water, and what little water it held drained out immediately upon removal of the hose. No percolation rate has been established for this hole. Percolation hole number 2 was located more towards the middle of the proposed absorption field, and had a percolation rate of 42 -minutes per inch, based on the slowest rate in that hole. This value is similar to the average 40 -minutes per inch rate reported in the Hepworth- Pawlak report Number 197-602 of November 28, 1997. Percolation hole number 3 was the northern -most percolation test hole. It had a reported percolation rate of 4 -minutes per inch. Because of the variability of the percolation rates, and the presence of existing Infiltrator chambers and a possible gravel field of unknown extent, we are requiring that two additional percolation tests be performed on the soil at the depth of the proposed absorption field, after all existing Infiltrator chambers have been removed. The plans note that the extent of the gravel field will be identified, to the degree possible, and, if necessary, changes to the field depth, and the composition will be made after the second set of percolation tests have been completed. The existing septic tank is believed to be a Copeland 1,000 -gallon, two-compartment concrete tank. The minimum tank size for the two bedroom residence, with garbage grinder, would be 703.125 -gallons (2 x 2 x 75 x 1.5 x 1.25 x 1.25). The plans note that either: 1. The tank volume mark must be found and exposed for inspection. 2. The internal tank dimensions must be measured in the field, and the actual volume calculated. Any volume greater than the minimum 704 -gallons will be adequate for this residence. Peiterson OWTS — addendum to the Permit Submittal. Wednesday, October 8'h, 2008 Page 2 of 4 Also, the plans note that an effluent filter must be added to the outlet of the existing septic tank, so that the system can comply with the current Pitkin County regulations. We require a PolyLok PL -122 effluent filter, with 1/16 -inch filter slots be installed. We recommend, but do not require, that a "SmartFilter" filter alarm be installed. The available space for the absorption field is limited by the well offset, the property line offset, a storage shed, a steep slope on the northern extent of the field, the existing driveway and the building offset. The field is roughly rectangular, with dimensions of approximately 56 -ft. by 13.5 -ft. However, the northern end of the field narrows down considerably, and so placing Infiltrator chambers in the available area, and not intrude into the driveway or other setbacks would be nearly impossible. Therefore, we have elected to install a deep -gravel absorption field, with two perforated distribution pipes fed from a dosing pump to be installed in a manhole, near the septic tank. Following an earlier meeting, the issue was raised of the third bedroom in the basement of the residence. As a bathroom with a shower, and an egress window is in the basement, we agree with Pitkin County's evaluation that the room must be considered a potential bedroom, regardless of any other statements to the contrary. Accordingly, we have revised our plans and calculations for a 3 -bedroom residence. Because the available space dictates that a deep gravel field be constructed, and because the 3 -bedroom design means that this gravel field will be at least 7.75 -feet below the distribution piping, the owner has advanced the existing profile hole to a depth of 12 -feet (plus) below native soil. From the bottom of this excavation, we extracted a representative sample of the soils, approximately 2 -gallons, in a plastic bucket. The bucket was immediately taken to HP Geotech, with instructions to perform a gradation and hydrometer test to determine the proportions of gravel/sand, silt and clay in the sample. We received the results of this test yesterday, and agree with HP Geotech's evaluation of the soils at the bottom of the excavation as being a Sandy Loam. The range of percolation rates associated with this type of soil is from 1 1 -minutes per inch to 20 -minutes per inch. As stated above, our design is based on a single percolation test result, of 42 -minutes per inch. In order to both comply with State and Pitkin County regulations, and also to minimize the amount of soil that must be exported from the site, and the amount of gravel that must be brought in, we propose the following: A. Excavate to the design depth of the field, at the current design percolation rate of 42 - minutes per inch. B. Conduct at least two new percolation tests, at the bottom depth of the field, to confirm the appropriate percolation rate for the field. C. Revise the design calculations, both for the overall field size, and also for the deep gravel formula, to correspond to the accepted percolation rate. D. Place the separation fabric around the entire perimeter of the field, to the depth indicated in "C" above. Petterson OWTS — addendum to the Permit Submittal. Wednesday, October 8'h, 2008 Page 3 of 4 E. Place the appropriate amount of screened gravel in the field to correspond to the depth established in "C" above. F. Place the 6 -inch minimum washed gravel field, and perforated pipe segments, above the screened gravel. Plumb and test the perforated pipe for flow. G. Place the remaining 6 -inches of washed gravel over the perforated pipe segments. H. Lay the separation fabric over the entire surface of the field. I. Backfill with native soil to a level at least 2 -feet above the native soil in the immediate area, to protect the perforated pipe from crushing, and to discourage driving over the field. If you have any questions, please call me at (970) 945-2550 extension 206, or email me at tcpagePgambaengineering.com. Sincerely, Gamba & Associates, Inc. �' . YIYYYY• • ,I N Id • Z Si jio� cc: Eric Petterson HA08706\Communications\Revised Addendum to the permit submittal.doc Petterson OWTS — addendum to the Permit Submittal. Wednesday, October 8th, 2008 Page 4 of 4 OC -F-07-2008 14:01 From:HP-GEOTECH GecPtech FAX TRANSMITTAL FORM DATE: � 6/ -7 R - 9709458454 To:9451410 P.1'2 HEPWOI. PAWLAK GEOTECHNICAL, INC. 5020 County Road 154 Glenwood Springs, Colorado 81601 Phone: 970-945-7988 Fax: 970-945-8454 e-mail; hpgeo@hpgeotech.com PROJECT NO.: TO. Pct A7� FAX NO: FROM: '� ktj 444- ' D ( --'j Number of Pages: >— (including this page) MESSAGE: The original of this transmittal will be sent by: Ordinary Mail `cFu Overnight `E3 / Fax Only 'ED Other "Eu The information contained in this facsimile message is confidential and intended for the sole use of the individual named above. If you are not the intended recipient, received this communication in error, or if problems occur with transmission, please notify us at 970-945-7988. Sent By: USDA GRADATION TEST RESULTS 0 ca- Cg- �v percent silt Figure 9.1 USDA Triangle Chart 02 -ZZ �B©e>Q M— �c�r�� co SAKI0Y 40 NP( �0. -� z pp-kz- /D A y N _ Tank & Fiekt-Trenches P2ge 1 10/8/20082:21 1 HA0870611SDS Calculations 20081007.xls Pitkin County Health Department Onsite Wastewater Treatment System Pressure -Dosed Pipe with Deep Gravel - Revised October 7, 2008 Individual Sewage Disposal/Treatment System Type: Se tic Tank 11 Parcel No. 2729-293-04-011 Owners Name and Address: ,1,d -" '+r: " ' Project Number:; 08706 House Size (sq. ft.):1,000 75 gallons/person/day, Yes Garbage Disposal? (Y/N) 11 - - --- Number of Bedrooms in Main House 3 Number of Offices, Libraries, Studies, Similar -sized Rooms in Main House 0 Number of Bedrooms in Detached Caretaker unit N/A Number of Offices, Studies, Similar -sized Rooms in Caretaker Unit (If the caretaker unit is ATTACHED, treat as if part of main house.) N/A irnmum o earoom Total Bedrooms and Potential Bedrooms: 3 equivalents. Additional flow in gallons/petson/day due to hvo (2) bathrooms, assume water 0 closet, lavatory, and shower. 0 0 persons using additional bathrooms. Average Daily Waste Flow: 450 allons/day State ReviewRequired?: No Average Percolation Rate (t) = 42.0 minutes/inch Design Flow (Q) =Average Daily Waste Flow X 1.5 Design Flow, Q = 675 gallons/day Percolation rate is WORST (slowest) encountered in tests by TJK on 09/02/08 - >5-mpi, 42-mpi, 4 -mi Absorption Area = A = 1.4(Q x t) A = 1224.86 sq. ft. of absorption area required 1,225.00 sq.ft. (Rounded Area) A (french) = 612.43 sq. ft.. Trench System: 50 % Reduction (with Dosing) A (Bed) = 857.40 sq. ft.. Bed System: 30 % Reduction (with Dosing) INFILTRATORS for Pitkin County Number of Infiltrator Units (TRENCH) 62.49 Quick4 Rounded Number of Units: 63 21 trenches of 32.00 units each This option REQUIRES an 20.50 feet wide X Too Long feet long automatic dosing siphon OR Unit Length: 4.00 Row Separation: 8.83 #VALUE! sq. ft. of trenches an effluent pump, either will require a separate tank Unit Width: 2.83 Actual number of Infiltrators for %quare" field/trench = 64.00 units Infiltrator Cost (ea.) = $28.00 Cost of Infiltrators = $1,792.00 Number of Infiltrator Units (BED) 93.20 Cl Rounded Number of Units: 94 bed system, 4 units wide, and 24.00 units long. 12.58 feet wide X 96.00 feet long Unit Length: 4.00 Row Separation: 3.25 1,208.00 sq. ft. of trenches Unit Width: 1 2-831 1 Actual number of Infiltrators for "square" field/trench = 96.00 units Infiltrator Cost (ea.) = S28.001 Cost of Infiltrators = S2,688.00 LTAR Site Soil Conditions:11 Percolation Rate (from above): Design Q (from above) = Absorption Area = Maximum Loading Rate = A = A (Trench) = A(Bedj = for Pitkin County Sandy Loam to loam see Table 42 he design loading rate may be based on the Long Term Acceptance 945 lata, LTAR. LIAR is the Maximum Loading Rate. in qallons per square Soil and Parc Rote Consistant? 0.72 gol/sq. ft./day, from Table Parc Rate & Soil Texture Inconsistant 1312.S0 sq. ft, of absorption area required 656.25 N. ft.. Trench System: 50 % Reduction 918.75 sq. ft.. Bed System: 30 % Redudion Clay Loam to Clay Maximum Suggested dosing Percolation Rate Loading Rate (go[ frequency � minutes / inch Typical Soil Textures / sq. ft. / day) (doses/day) um r o n trator mts (TRENCH) (15.5 sq.ftdunit) Rounded Number of Units: Infiltrator Cost (ea] =F_11 42.34 STANDARD units (,nominal) 43 LJ trenches of 30 feet wide X Actual number of Infihmtom for "square' field/trench = 87011 Cost of Infiltrators = $1 232.00 11.00 units each 66.00 feet long 1,980.00 sq. ft. of trenches 44.00 units 0 to 5 Gravel Not Suitable 1 to 5 Coarse to Medium Sand 1.30 4 6 to 10 Fine Sand to Loamy Sand 1.20 1 11 to 20 Sandy Loam to Loam not critical Number of Infiltrator Units (BED) (15.5 sq. ft./unit) Rounded Number of Units: Infiltrator Cost (ea.) = 59.27 STANDARD units (nominal) 60 bed system, C� units wide, and 12 feet wide X Actual number of Infiltrators for "square" field/trench = 528.00 Cost of Infiltrators = $1,680.00 15.00 units long. 90.00 feet long 1,080.00 sq. ft. of trenches 60.00 units 21 to 30 Loam 0.50 1 31 to 40 Loam to Silty Loam' 0.40 1 41 to 60 Clay Loam to Clay 0.30 1 60 & up Silty Clay Loam/Silty Clay 0.20 not critical 'Soils without highly expansive clays P2ge 1 10/8/20082:21 1 HA0870611SDS Calculations 20081007.xls John M. Ely County Attorney Christopher G. Seldin Assistant County Attorney Carrington Brown Code Enforcement Officer Mr. Eric Petterson 222 Bobcat Lane Redstone, Co 81623 Dear Mr. Petterson, w -7.. '75 PITKIN COUNTY ATTORNEY Courthouse Annex Building 530 East Main Street, Suite 302 Aspen, Colorado 81611 Tel: (970) 920-5190 Fax: (970) 920-5198 Legal Assistants: Lisa MacDonald Jane Achey June 9, 2008 I am the Pitkin County Code Enforcement Officer and this letter serves as a Notice of Violation for your property located at 222 Bobcat Lane, Pitkin County. I have received complaint that this property is not in compliance with the Pitkin County Land Use Code. There are several allegations, the ones that may have merit are: 1) Three sheds have been placed on the property. One or more of the sheds appear to be placed inside the property line setbacks (too close to the property lines) and Pitkin County Community Development records do not contain evidence of permits being obtained for any of these sheds. 2) A fence has been installed that may not be compliant with the County fencing regulations. 3) A dog is allegedly allowed to run about the property in violation of the March 27, 1997, 1041 Hazard Review and Conceptual Submission, paragraph 8, stating "only one dog is permitted on the property and the dog shall be kenneled." 4) The septic system was allegedly recently replaced with a dry well septic that was not subjected to a Pitkin County Environmental Health and Natural Resources review and permit. It is also alleged that the driveway and certain sheds are located over the septic field which would also be a Code violation. To cure this Notice of Violation please take the following steps: 1) Apply for and obtain permits from Pitkin County Community Development for each of the three sheds by July 15th, 2008. The forms are located at Pitkin County website, including http•//www aspenpitkin com/pdfs/depts/7/buildin -fg orm.pdf and http•//www aspenpitkin com/t)dfs/depts/7/building-permit-instr.-odf. Please be advised that if it zoning staff decides it is not possible to issue a permit for locating the sheds on the property, then they must be removed from the property within 30 days of your being so notified. 2) Please make arrangements to meet me at your property to examine and discuss the fencing by June 20th, 2008. 3) Contact Nancy McKenzie at Pitkin County Environmental Health and Natural Resources (920-5070) by June 20th, 2008 to obtain the appropriate review and permits for the septic field and provide her an explanation of the septic field's location relative to the driveway and sheds. 4) Provide explanation of the dog and kennel situation when we meet to examine the fence. If you do have a dog, please be advised that you will be required to adhere to the requirement for the dog to be kenneled. Thank you for your prompt attention to this matter and I look forward to you contacting me at 429-2814 to arrange a meeting at your property. Sincerely, Carrington Brown Pitkin County Code Enforcement Rose Ann Sullivan From: Eric Petterson [eric.petterson@starband.net] Sent: Thursday, July 24, 2008 5:07 PM To: Nancy Mackenzie; Carrington Brown Cc: Rose Ann Sullivan; 'Peter Martin' Subject: RE: NOV - septic 220 Bobcat Lane All- in response to your email, for clarification, I removed gravel from where I thought the absorption bed was, and this mean that only about 10 sq ft of the actual absorption bed had gravel removed (I didn't have the as-builts when the contractor was out scraping gravel). I have called 2 contractors to remove the rest of the gravel, and re -contour per Nancy's direction. I am hoping one of them can be out here by the 3`d, but it is somewhat out of my hands. As soon as I get a date from a contractor, I will let you all know when all this will happen. I've also emailed Nancy to let her know that as soon as a contractor is lined up to expose the piping, I'll give her the heads up so she can get out right away, so I can proceed with finishing up the work she's requested as fast as possible. Thank you Eric Petterson Rocky Mountain Ecological Services, Inc. phone/fax: 970-963-2190 mobile: 970-309-4454 eric. petterson CcDstarband. net From: Nancy Mackenzie [mailto:Nancy.Mackenzie@co.pitkin.co. us] Sent: Thursday, July 24, 2008 4:01 PM To: Carrington Brown Cc: Eric Petterson; Rose Ann Sullivan Subject: NOV - septic 220 Bobcat Lane Carrington, I visited this site yesterday, July 23, 2008. No gravel had been removed from the top of the absorption bed. The shed closest to the road had not been moved. The shed at the back of the driveway had been removed. Eric had located the area for the absorptioi . drea based on the as -built drawing in our files. Our drawing indicates there is a bed of gravelless Standard size (3 ft X 6 ft) Infiltrator units 5 units wide by 6 units long, for a total area of 15 feet by 36 feet. His locate indicated that part of the driveway, a landscaped berm, a portion of the berm that the shed is sitting on and a portion of the shed are all located on top of the absorption field. 1)I have asked Eric to immediately stop parking on the portion of the driveway that is over the absorption bed. The area of the bed is to have a barrier so that there is no more traffic in this area. 2) 1 have a concern because the bermed shed is located on the manifold piping area of the absorption bed. The construction and weight might have broken the piping. I have requested that this area of the absorption field be exposed and inspected by me to verify that the piping is intact. 3) After the shed is removed, the gravel berm under the shed must be removed and the area brought done to grade. The landscaped berm does not have to be removed. It must be gradually sloped down over the absorption bed to prevent water from ponding on top of the absorption field. 4)Once the driveway gravel is removed from the top of the bed it must be replanted with grass. We discussed the advantage of seeding the area with the appropriate type of grass that does not require watering once it is established. I reminded Eric that the Notice of Violation requires this to be accomplished by August 3, 2008. Nancy C Rose Ann Sullivan From: Nancy Mackenzie Sent: Thursday, August 28, 2008 10:03 AM To: Rose Ann Sullivan; Carla Ostberg Subject: FW: petterson #2 Attachments: letter 8.27.08.doc Fyi I heard that the house might be under contract, so I let Carrington know this. I'm concerned that Eric will sell the house before our due dates. Carrington said he would discuss with Ely how to (or not) handle this. From: Carrington Brown Sent: Thursday, August 28, 2008 8:14 AM To: Nancy Mackenzie Cc: Tony Fusaro Subject: petterson #2 Thanks for your suggestions and please check out this final draft of the Petterson letter. Carrington Brown Pitkin County Code Enforcement 970-429-2814 970-379-6872 PITKIN COUNTY CODE ENFORCEMENT Courthouse Annex Building 530 East Main Street, Suite 302 Aspen, Colorado 81611 970-429-2814/970-379-6872 8/27/08 Mr. Eric Petterson 222 Bobcat Lane Redstone, Co 81623 Dear Mr. Petterson, I am writing you regarding the status of the Notice of Violation I issued you on June 9, 2008 for your property located at 222 Bobcat Lane, Pitkin County. I understand that you have cured some of the Notice by moving the yard fence onto your property, removing one illegal shed and you have applied for permits for the two remaining sheds. I also understand that you have been communicating with Nancy MacKenzie of Pitkin County Environmental Health and Natural Resources regarding the status of the septic field. I understand that Mrs. MacKenzie required that you remove the earth over the manifold system for inspection. I recall that you told me you were reluctant to do this and Mrs. McKenzie then suggested that you have the manifold inspected via in -pipe video. To date neither of these inspections has taken place as you have not taken the necessary steps. I have been recently informed that you have hired Mr. Carter Page of Gamba & Associates, Inc. to design a new septic field because, according to what Mr. Page tells us, the current septic field is allegedly in unsatisfactory condition (crushed manifold pipes and gravelless chambers) and will not pass the Pitkin County inspection. Unless otherwise concluded via inspection we consider this septic field to be a "failed system" that needs immediate replacement. Your hiring an engineer to design a new septic field supports this conclusion. Having an engineer design a new septic field is an appropriate first step towards replacing the field. However, in order for the County to issue a permit for the new septic field we must know how many bedrooms and bathrooms are in the house. The house originally received its C.O. with 2 bedrooms, one bathroom and an unfinished basement. I now understand that there is a possibility that the basement has been finished and that it now contains a bedroom and a bathroom, bringing the total for the house to 3 bedrooms and 2 bathrooms. This possibility is supported by the fact that the house is currently listed for sale by Mason and Morse as having 3 bedrooms and 2 bathrooms. In this case, the new septic field needs to be designed to accommodate these additions. In order for the County to process your pending septic permit, we will need to verify, via inspection, how many bedrooms and bathrooms are in the house. If we find that the "unfinished" basement has been finished you will be required to apply for and obtain building permits for work performed. As part of that process you have two options for the inspections related to issuing those building permits: 1) obtain notarized affidavits from a Colorado State licensed carpenter, plumber and electrician attesting that the work was performed to all pertinent Building Code standard and from a state licensed engineer if structural changes were made, or 2) remove sufficient dry wall so County inspectors can view/inspect the piping, electrical and framing of the areas finished/installed without permits. You may make this decision with County Building Department staff. 11 In summary, in order for you to conclude curing the Notice of Violation against this property please do the following: 1) Replace the failed septic system: a) Apply for and obtain a Pitkin County septic permit for a septic system designed to accommodate the number of bathrooms and bedrooms currently in the house. b) The septic permit process includes an inspection of the house by County staff to establish the number of bedrooms and bathrooms. Please keep in mind that if your lot will not accommodate a septic field of sufficient size for the number of bedrooms and bathrooms currently in the house you will be required to reduce the number of bedrooms and bathrooms to the number originally present when the house received its C.O. 2) The failed septic system must be replaced and successfully inspected by Pitkin County no later than October 30`h, 2008. In order to accomplish this please submit your complete septic application, based on a professionally produced design, to Pitkin County Environmental Health and Natural Resources by September 15`h, 2008. Arrange for the house inspection establishing the number of bedrooms and bathrooms to be completed by September 15, 2008. 3) Submit for and obtain buildin� permits for the work done in the originally unfinished basement area by October 30', 2008. 4) Conclude obtaining permits for the two sheds by September 15`h, 2008. Please be advised that if the new septic location/size will not accommodate one or either of these sheds the shed in question will need to be moved to another location and subject to permits for that new location. Mr. Peterson, we appreciate your efforts to date to remedy the code violations on your property. I look forward to your completing the cure of the Notice of Violation according to the dates given above and if you have questions about how to do so, please contact me at 429-2814. Your contact in Environmental Health and Natural Resources is Carla Ostberg at 920-5438 and your contact in the County Building Department is Tony Fusaro at 920-5101. Sincerely, Carrington Brown Pitkin County Code Enforcement Cc: John Ely, Pitkin County Attorney Tony Fusaro, Pitkin County Building Department Joanna Schaffner, Pitkin County Zoning Officer Carla Ostberg, Pitkin County Environmental Health and Natural Resources Lance Clark, Pitkin County Community Development Carla Ostberg From: Carrington Brown Sent: Friday, October 03, 2008 8:55 AM To: Carla Ostberg Cc: Rose Ann Sullivan Subject: FW: basement permit fyi Carrington Brown Pitkin County Code Enforcement 970-429-2814 970-379-6872 From: Eric Petterson [mailto:eric.petterson@starband.net] Sent: Friday, October 03, 2008 8:50 AM To: Tony Fusaro Cc: Carrington Brown Subject: RE: basement permit Yep, I need some more detail on the floor plans for the septic permit too- in that bathroom with the toilet there is a sink and a walk-in shower that came with the house when we bought it. I'll show those in the drawings. Thanks and take care.... Eric Petterson Rocky Mountain Ecological Services, Inc. phone/fax: 970-963-2190 mobile: 970-309-4454 eric pettersonCcDstarband.net From: Tony Fusaro [mailto:Tony.Fusaro@co.pitkin.co.us] Sent: Friday, October 03, 2008 8:36 AM To: Eric Petterson Subject: RE: basement permit Eric, How are the floor plans coming? And one question: I never looked into the bathroom in the basement, so could you tell me what fixtures are in it, like shower or tub or lavatory. I did see the toilet. Glad to hear things are progressing Tony Fusaro Chief Building Official Pitkin County 970-920-5101 www.aspenpitkin.com Don't forget that you have a deadline to meet for Carrington. From: Eric Petterson [ma iIto: eric.petterson@starband.net] Sent: Thursday, October 02, 2008 9:00 PM To: Tony Fusaro Cc: Carrington Brown Subject: RE: basement permit Amb Tony- I got your voice message today. I had the office reviewed by an electrician, and he had a few changes that he wanted to bring the office into compliance (the ground needed to be "floated", and some other things- don't ask me though, Im not an electrician!). We had that done, and now the only thing left is to have the electrician sign the affidavit. The electrician also reviewed the basement, and he indicated everything looked good. We also had a plumber review the basement, and he said that the washing machine "dump" into the septic pipes was not to code. He indicated that he could reconfigure the "dump" to bring it into compliance, but it would take some work. He indicated that he was pretty booked up, but that he should be able to address the washing machine issue likely next week (we had him come out about a week and a half ago). Carter Page (P.E. with Gamba engineering) is working with Carla regarding our leachfield- she has some modifications to Gamba's plans, which I will be working with Carter on tomorrow. We are planning to get the leachfield done ASAP based on permitting and contractor timelines. Thanks for all your patience, feel free to call, email, or stop by anytime... Eric Petterson Rocky Mountain Ecological Services, Inc. p hone/fax: 970-963-2190 mobile: 970-309-4454 eric. petterson Cab-starband. net From: Tony Fusaro[mailto:Tony.Fusaro@co.pitkin.co.us] Sent: Thursday, September 04, 2008 3:57 PM To: eric.petterson@starband.net Cc: Carrington Brown Subject: basement permit Eric, Thanks for the grand tour yesterday. I double-checked the archived plans for the house, and there was no indication that the room partitions in the basement were ever proposed to or approved by the building department. I can only conclude that the basement was unfinished at the time of final inspection, as is noted on the final inspection form. Mr. Harsh's letter confirms that work was done without permit, so it looks like the improvements need to be legalized. I am attaching some affidavits that you can use for this process. There are no structural changes, so I have not included an affidavit for an engineer. If you have questions, call me at 920-5101. You need to submit a building permit application as I explained during my visit. The form can be downloaded from our website, aspen pitkin.com. The plans will be reviewed by our plans examiner. The affidavits will suffice for plumbing and electrical inspections, and a final safety inspection will be needed. As a homeowner, you can prepare the plans and submit the application. Regards, Tony Fusaro Chief Building Official Pitkin County 970-920-5101 www.aspenpitkin.com Page 1 of 2 NW Carla Ostberg From: Joanna Schaffner Sent: Monday, September 08, 2008 1:12 PM To: Carla Ostberg Subject: RE: Petterson shed Please let me know when something has been approved. From: Carla Ostberg Sent: Monday, September 08, 2008 10:59 AM To: Joanna Schaffner Subject: RE: Petterson shed I haven't seen anything come in yet, so it will have to be on hold for the time being. Carla Ostberg, REHS Environmental Health Program Supervisor Pitkin County Environmental Health and Natural Resources 970-920-5438 From: Joanna Schaffner Sent: Monday, September 08, 2008 8:48 AM To: Carla Ostberg Subject: FW: Petterson shed Have the new septic plans been finalized? Is there a plan? I have a shed permit and need to know where it can't go. From: Carrington Brown Sent: Monday, September 08, 2008 8:31 AM To: Joanna Schaffner Subject: RE: Petterson shed There were three sheds. One is off the property. Another is used as a office and another remains on or real near the old septic. I suggest you contact him and ask him to describe the shed's new location relative to the new septic field he is building. Carla can tell you if it will the new field has to be bigger than the original one and thus would effect the shed's new location. So, permits are needed for the two remaining sheds. I won't be at the staff meeting - other pressing issues. Carrington Brown Pitkin County Code Enforcement 970-429-2814 970-379-6872 From: Joanna Schaffner Sent: Monday, September 08, 2008 8:25 AM To: Carrington Brown Subject: Petterson shed I somehow lost track of all the emails on this shed thing. Apparently he relocated the shed but now its on the QfR i1)nnR • • Page 2 of 2 septic field? Is this correct? 9/8/2008 Rose Ann Sullivan From: Carla Ostberg Sent: Monday, September 22, 2008 10:07 AM To: Rose Ann Sullivan Subject: FW: sale of 222 Bobcat This is an exchange between Carrington and Eric that I'm not sure I put in the file. Carla Ostberg, REHS Environmental Health Program Supervisor Pitkin County Environmental Health and Natural Resources 970-920-5438 From: Carrington Brown Sent: Thursday, September 11, 2008 8:16 AM To: 'Eric Petterson' Cc: Carla Ostberg; Joanna Schaffner; Tony Fusaro Subject: RE: sale of 222 Bobcat Eric, I'm sorry to hear of the contract failure. That aside, the remaining violations on your property need to be cured as soon as possible. Please provide me an update on your shed permits and the new septic field status. I understand you are working with Tony Fusaro to remedy the unpermitted basement work. Regarding the fence, one of your neighbors told me about 2 weeks ago that there is interest among your neighbors in obtaining (and paying for) a survey of the private road that services your subdivision. I suggest you communicate with your neighbors about that possibility. Thank you - Carrington Brown Pitkin County Code Enforcement 970-429-2814 970-379-6872 From: Eric Petterson [mailto:eric.petterson@starband.net] Sent: Wednesday, September 10, 2008 10:21 PM To: Carrington Brown Subject: sale of 222 Bobcat Carrington- the contract on our house fell through, so we're going to be here for a while unless a new buyer falls out of the sky... We'll keep plugging away at the remaining issues. A couple of people have now hit those poles in the road that Sherman put up. They are within the 30' wide roadway about 5 to 6 feet as measured from the survey stakes installed by Lines -in -Space, could you have Mr. Sherman move those darn things onto his property? thanks Eric Petterson Rocky Mountain Ecological Services, Inc. phone/fax: 970-963-2190 mobile: 970-309-4454 eric petterson(a)starband.net l Rose Ann Sullivan From: Carla Ostberg Sent: Monday, September 22, 2008 10:06 AM To: Rose Ann Sullivan Subject: FW: petterson septic E From Carrington... this was when I started asking Carter the progress on the new system design. Another email to follow. Carla Ostberg, REHS Environmental Health Program Supervisor Pitkin County Environmental Health and Natural Resources 970-920-5438 From: Carrington Brown Sent: Thursday, September 11, 2008 8:24 AM To: Carla Ostberg Subject: petterson septic Hi Carla, I see Petterson's sale fell through and his incentive to install the new septic is no doubt less than when the sale was healthy. This Violation has gone on quite awhile and we need to keep pressure on him to promptly install the new septic. What is the status of his new septic system? And, if he proves too slow or unwilling to install the new septic, does your code/law allow the county to declare his current septic unusable (due to the crushed pipes,etc) and therefore the house unlivable? Thanks -C Carrington Brown Pitkin County Code Enforcement 970-429-2814 970-379-6872 Wk(szn • Page 1 of 3 Carla Ostberg From: Carrington Brown Sent: Wednesday, September 03, 2008 12:47 PM To: Tony Fusaro Cc: Carla Ostberg Subject: RE: permit required for landscaping? Tony, I'm happy he has checked with Catherine and Susan but in order to be sure I suggest Brian take a look. This would also enable us to tell inquiring neighbors that we thoroughly checked out the situation. Hopefully Petterson gets to you asap as we definitely need a look/see in that basement and he can't design his septic until we do. Thx-C Carrington Brown Pitkin County Code Enforcement 970-429-2814 970-379-6872 From: Tony Fusaro Sent: Tuesday, September 02, 2008 5:02 PM To: Carrington Brown Subject: FW: permit required for landscaping? Carrington, I spoke to Roger today and he has been in communication with Catherine Berg and Susan Pearson about the work he was planning around his house. Both have said no permit is required. He sent me a number of emails backing this up, one of which I am forwarding to you. It seems he has done due diligence. I have not yet received a reply from Petterson and don't have an appointment to see him, but Roger has invited me to stop by anytime to see what he is doing. Tony From: Roger Sherman [mailto:blueox@hughes.net] Sent: Tuesday, September 02, 2008 4:42 PM To: Tony Fusaro Subject: Fw: permit required for landscaping? Roger Sherman office: 970.963.3689 cell: 970.618.2610 ----- Original Message ----- From: Catherine Berq To: Roger Sherman Sent: Thursday, July 17, 2008 11:37 AM Subject: RE: permit required for landscaping? Roger, There is no need for a permit since you are moving less than 50 cy of material. Thanks, 9/;/SMR Page 2 of 3 Catherine Berg Planning Engineer Community Development Pitkin County 130 S. Galena Street, Aspen, CO 81611 970.429.2790 (Phone) 970.920.5439 (Fax) catherinebAco.pitkin.co. us From: Roger Sherman [mailto:blueox@hughes.net] Sent: Friday, July 04, 2008 11:02 AM To: Catherine Berg Subject: Re: permit required for landscaping? We will be disturbing a small fraction of 50cy. I have attached 4 photos showing the existing rock work. We have several options we are pursuing to replace the rocks. We also will be putting in rock pavers around the house but within the original building envelope. We also want to apply cultured stone to our foundation wall as that was never completed when we built the house 16 yrs ago. I will list our options as follows and if you can give me a yes or no to each option as to whether a permit is required that will help us determine what we will do. 1. replace the rockwork under the front deck with pre -formed landscaping blocks (small 6x8x8 blocks available at local outlets) stacked up similar to existing rock. 2. replace the rockwork under the front deck with concrete block faced with cultured stone. 3. replace the rockwork at the driveway with pre -formed landscaping blocks stacked up similar to existing rock. 4. replace the rockwork at the driveway with concrete block faced with cultured stone. 5. replace the rockwork at the driveway with concrete block (to hold in road base) faced with sloping soil/sod. 6. apply cultured stone to the house foundation wall. 7. install stone or pre -formed pavers for walkways from driveway to house and around house. We plan on doing this by hand by ourselves in the course of the next year or two. Let me know if this is enough info. Roger Sherman office: 970.963.3689 cell: 970.618.2610 ----- Original Message ----- From: Catherine Berg To: blueox(a hug_hes.net Sent: Tuesday, June 24, 2008 10:53 AM Subject: FW: permit required for landscaping? Roger, I received your email below. How much soil are you planning to disturb? If it's more than 50cy then you need a permit. Also, I'd like to take a look at your plan to see if the work would be done within your building envelope or if you might need some further planning. Please give me a call if you have any questions. Thanks! Catherine Berg Planning Engineer Community Development Pitkin County 130 S. Galena Street, Aspen, CO 81611 970.429.2790 (Phone) 970.920.5439 (Fax) 9/3/2008 C Page 3 of 3 catherineb(cDco pitkin.coms From: Roger Sherman [mailto:blueox@hughes.net] Sent: Monday, June 23, 2008 9:14 PM To: web_pitkinl Subject: permit required for landscaping? I plan on doing some landscaping rock/masonry work on our property. All work is less than 30" above grade. Specifically, I plan to replace existing loose rock -stack perimeters around our driveway and house with masonry work and add some patio pavers in various areas. Does this landscaping work require a permit? Are there any other related building/zoning requirements I need to know about? Roger Sherman home: 970.963.3689 cell: 970.618.2610 9/3/2008 Nancy Mackenzie From: Nancy Mackenzie Sent: Thursday, August 21, 2008 3:24 PM To: Nancy Mackenzie Subject: FW: Eric Pettersen 222 Bobcat Lane - the next chapter From: Nancy Mackenzie Sent: Thursday, August 21, 2008 3:21 PM To: Carrington Brown Cc: Rose Ann Sullivan; Carla Ostberg Subject: Eric Pettersen 222 Bobcat Lane - the next chapter Carrington, Funny that Eric was unhappy with us requiring him to prove that the manifold to his septic system is intact. Within a day, Eric had contacted an engineer to design a new septic field! The engineer said that Eric told him the system had failed a couple of years ago. Driving the cars on top of the field had crushed the Infiltrator units. So Eric put loads of gravel on top of it (just as the neighbor had alleged). So this is the reason Eric has been trying to get out of exposing components of the septic field. Eric also told the engineer that there is an 'office' in the basement AND a bathroom. The original septic permit and the CO for the building where for 2 bedrooms and 1 bath upstairs and an unfinished basement. I told the engineer that we would have to design the septic field for the correct number of bedrooms. The building department must get involved in inspecting the basement since there are no permits for this work. At that point we can determine if it is just a powder room in the basement or a % or full bath that would make the 'office' a potential bedroom. Nancy From: Nancy Mackenzie Sent: Tuesday, August 19, 2008 1:47 PM To: Carrington Brown Subject: RE Eric Thanks for passing on the flyers. I talked to Eric. He wasn't having any luck digging to expose the manifold pipe for the septic field. So I told him another way would be to have the pipe scoped with a TV camera. So he said he would call around to have that done. I asked him to call me and let me know when and I'd try to be out there. From: Carrington Brown Sent: Tuesday, August 19, 2008 11:00 AM To: Nancy Mackenzie; Catherine Berg Subject: RE: unlicensed food vendors Ok, will do Nancy and I will also carry home flyers for job sites. -C Fyi Nancy, Eric called today, unhappy about the latest turn in his septic drama. I told him to work it out with you and he seemed to conclude that is his best course of action. -C Carrington Brown Pitkin County Code Enforcement 970-429-2814 970-379-6872 Nancv Mackenzie From: Nancy Mackenzie Sent: Wednesday, August 06, 2008 1:03 PM To: 'Eric Petterson' Subject: RE: leach field update Eric - Thank you for the picture. It really show what you have accomplished in compliance up to now. Should we schedule an inspection on the 14th? I think you should plant the annual ryegrass since the natives take longer. When I planted grass I got a white cloth covering that kept the moisture in and was a protection from intense hit. So I used less water and my grass came up much faster. You might want to try that so you'll have grass for all the potential buyers to look at. Nancy From: Eric Petterson [mailto:eric.petterson@starband.net] Sent: Wednesday, August 06, 2008 8:15 AM To: Nancy Mackenzie Cc: Carrington Brown Subject: leach field update Nancy -just to let you know, last Saturday (August 2), 1 had a dirt work contractor scrape off the gravels, recontour the berm above the leach field, spread the topsoil, and place rocks to keep vehicles from going on the leach field, and about a week previously, we had the shed moved to the back of our driveway (its entirely off the leachfield now). See attached photo. We ran out of time to dig a hole to expose the pipes, and I thought he was going to come back on Sunday to help me with exposing the pipes, but he called and said he would like a day off (I can understand that). Im leaving on Friday for California to see a new nephew, and will be back on the 13th. The contractor isn't available in the next 2 days to dig the hole, and I'd like to be there anyway. So upon my return from California, I will get the contractor up here and expose those pipes for you. Also, I have ordered some native seed from Granite Seed for reveg'ing on top of the leachfield, but I would like to seed this fall, as you get a much better germination/survival rate. One option is I could plant a "temporary" seed mix immediately, like annual ryegrass, which would persist for one growing season, while the natives are coming in (they grow very slowly... ). I'll be using certified weed -free straw for a mulch. Thanks for you guidance... Eric Petterson Rocky Mountain Ecological Services, Inc. phone/fax: 970-963-2190 mobile: 970-309-4454 eric. petterson(aD-starband. net fAw 1 i C Nancy Mackenzie From: Nancy Mackenzie Sent: Thursday, July 24, 2008 4:07 PM To: 'Eric Petterson' Subject: width of the absorption bed Eric, I forgot what you had established as the width of the absorption bed. In looking at the as -built, it was little confusing because of the notation (10' from property line) on the bottom under the dotted line. The actual width of the infiltrator bed is 15 feet since there are 5 units each 3 ft wide. Nancy c Nancy Mackenzie From: Nancy Mackenzie Sent: Thursday, July 24, 2008 4:01 PM To: Carrington Brown Cc: 'Eric Petterson'; Rose Ann Sullivan Subject: NOV - septic 220 Bobcat Lane Carrington, I visited this site yesterday, July 23, 2008. No gravel had been removed from the top of the absorption bed. The shed closest to the road had not been moved. The shed at the back of the driveway had been removed. Eric had located the area for the absorption area based on the as -built drawing in our files. Our drawing indicates there is a bed of gravelless Standard size (3 ft X 6 ft) Infiltrator units 5 units wide by 6 units long, for a total area of 15 feet by 36 feet. His locate indicated that part of the driveway, a landscaped berm, a portion of the berm that the shed is sitting on and a portion of the shed are all located on top of the absorption field. 1)1 have asked Eric to immediately stop parking on the portion of the driveway that is over the absorption bed. The area of the bed is to have a barrier so that there is no more traffic in this area. 2) 1 have a concern because the bermed shed is located on the manifold piping area of the absorption bed. The construction and weight might have broken the piping. I have requested that this area of the absorption field be exposed and inspected by me to verify that the piping is intact. 3) After the shed is removed, the gravel berm under the shed must be removed and the area brought done to grade. The landscaped berm does not have to be removed. It must be gradually sloped down over the absorption bed to prevent water from ponding on top of the absorption field. 4)Once the driveway gravel is removed from the top of the bed it must be replanted with grass. We discussed the advantage of seeding the area with the appropriate type of grass that does not require watering once it is established. I reminded Eric that the Notice of Violation requires this to be accomplished by August 3, 2008. Nancy Nancy Mackenzie 1 7 I U 1/._ 0 // From: Roger & Tammy Sherman [rtsherman@hughes.net] Sent: Friday, July 11, 2008 12:35 PM To: Nancy Mackenzie Cc: Carrington Brown Subject: Septic code violations Follow Up Flag: Follow up Flag Status: Flagged Per my conversation with Carrington Brown a few weeks ago, it appears that my concerns regarding the septic system at 222 Bobcat Lane (Pettersons) are not being taken too seriously. Carrington told me that Mr. Petterson claims that only a pipe was replaced. It is still my contention that part of the original septic system was torn up (evaporation domes, pipes, etc.) and a large hole dug and filled with several truckloads of gravel. I observed this work myself and was also told by Mr. Petterson that they were digging a large hole and filling it with gravel to replace the malfunctioning septic system. It is my contention that the septic system failed because of two reasons. First, the driveway was installed over the septic system by the original owner when the house was built and that has compacted the soil. Secondly, the original septic system was designed for a 2 bedroom, one bath house. This house is on the market now listed as a 3 bedroom, 2 bath house. Would you not only require the driveway to be moved, but also that the compacted soil be dug up and replaced? Will you follow up on my contention that the septic system was replaced, repaired illegally? Will you investigate the "Expanded use of an existing OWTS" which "includes the addition of bedrooms or rooms that may be used as bedrooms in the future, or the conversion of rooms into bedrooms, or any other modification that may affect water use"? How will the leach field be accurately staked out/measured and by whom? Will attention be given to the setbacks, and distances from house, tank, driveway, etc.? How can I be assured that the septic system won't be encroached upon and compacted again in the future? Is there a way to permanently mark the leach field with something such as buried wire around the perimeter which can be detected by a metal detector so it can easily be located in the future? Can I be updated periodically and be notified about any final resolutions that are proposed regarding these matters? Please respond. Thank you. Roger Sherman office: 970.963.3689 cell: 970.618.2610 Nancy Mackenzie From: Eric Petterson [eric. petterson@starband. net] Sent: Monday, July 21, 2008 8:31 PM To: Carrington Brown Cc: Joanna Schaffner; Nancy Mackenzie Subject: RE: septic layout Sounds good, thanks. At the BOA hearing, all I will be presenting is the setback for the shed that came with the property (built in 1999), as the other shed- once I move it off of the leach field, will be compliant with all setbacks- and then I'll get building permits for both... (?). The "shed movers" will be up in 2 weeks to move the shed off of the leach field to the back of the lot- the other shed was moved over a week ago... Also, I called some surveyors last week to survey the front yard, as part of an "improvement certificate"- that way I'll be sure my fence is in the right spot and fully out of the road- they said they would be up this week.... Eric Petterson Rocky Mountain Ecological Services, Inc. phone/fax: 970-963-2190 mobile: 970-309-4454 eric. Petterson CcDstarband. net From: Carrington Brown[mailto:Carrington.Brown@co.pitkin.co. us] Sent: Monday, July 21, 2008 7:45 AM To: Eric Petterson Subject: RE: septic layout Eric, You need to make application for permits for the sheds to Pitkin County and the setback measurements for the new location will be discussed as part of the permit process. -Carrington Carrington Brown Pitkin County Code Enforcement 970-429-2814 970-379-6872 From: Eric Petterson [mailto:eric.petterson@starband.net] Sent: Thursday, July 17, 2008 3:17 PM To: Nancy Mackenzie Cc: Carrington Brown Subject: RE: septic layout Unfortunately, I'll be in Breckenridge that day delineating wetlands, but you're more than welcome to look around. Let me know if you need anything else- but I'll see if Angelique (my wife) can be around for you.... Eric Petterson Rocky Mountain Ecological Services, Inc. phone/fax: 970-963-2190 mobile: 970-309-4454 eric. pettersonna.starband. net From: Nancy Mackenzie [maiIto: Nancy. Mackenzie@ co.pitkin.co.us] Sent: Thursday, July 17, 2008 2:41 PM To: Eric Petterson Cc: Carrington Brown Subject: RE: septic layout Thanks. I am planning to be up that way on Tuesday morning and will take a look. From: Eric Petterson [mailto:eric.petterson@starband.net] Sent: Thursday, July 17, 2008 2:24 PM To: Nancy Mackenzie Cc: Carrington Brown; Joanna Schaffner Subject: septic layout Nancy- I have laid out the "as builts" for the leachfield based on what you sent me- I painted it on the ground. Feel free to come up at your earliest convenience. I sure wish we had those as builts, as we wouldn't have had to dig up a bunch of the driveway to fix those pipes, and, as it ends up, the shed we had removed a couple of weeks ago ended up being outside of the leach field- but the one we kept is on part of the field. So we're going to move that shed to the back of our lot, which would make us in compliance with the 10' and 30' setbacks for our lot. Carrington, this means that I don't need to go in front of the BOA for that shed, but I assume I still have to for the north shed, which was built in 1999 and came with the property, and is over the 10' setback by about a foot. Is that correct? Thanks! Eric Petterson Rocky Mountain Ecological Services, Inc. phone/fax: 970-963-2190 mobile: 970-309-4454 eric pettersonCcb-starband.net Nancy Mackenzie From: Nancy Mackenzie Sent: Tuesday, July 15, 2008 3:47 PM To: 'eric. petterson@starband. net' Cc: Carrington Brown Subject: RE: Notice of violation Eric, In re -reading our agreement, I want to clarify #1. For my inspection, the gravel will need to be removed and I will need to see the precise location of the septic field. This will help me determine that it is still a bed with the 30 gravelless Infiltrator chambers and not a drywell. So the bed should have an exposed Infiltrator chamber. If everything is okay, then you can add grass by a pre -determined time that we can agree to at the time of my inspection. Nancy From: Carrington Brown Sent: Wednesday, June 18, 2008 12:06 PM To: 'eric.petterson@starband.net' Cc: Nancy Mackenzie; Joanna Schaffner; Lance Clarke Subject: Notice of violation Eric, Thank you for meeting with Nancy Mackenzie and me today at your property at 222 Bobcat. This e-mail's purpose is to summarize our observations and the next steps for you to take. 1) The driveway is at least partially on top of the septic field. You have agreed to establish the precise location of the septic field and then remove the gravel from on top of it and add grass in that area. You will also remove the shed that is located on top of the septic field and intend to remove the shed from the property entirely. Once this is completed please arrange for inspection with Nancy. This item #1 will be accomplished within 45 days from today, August 3, 2008. 2) You have agreed to make application for permits for the three sheds (two, assuming you remove the one shed mentioned in item #1), per my Notice of Violation, by July 15, 2008. Contact Joanna Schaffner of Pitkin County Community Development to deal with the permit requirement. This will be accomplished by July 15th, 2008. 3) You admitted that the picket fence is not located on your property as it passes along the road in front of your house and agreed to move it so it is on your property. In order to place it outside the development envelope you need to obtain a fence permit from Community Development (contact Joanna Schaffner 920-5105 for details) before moving the fence. This will be accomplished by August 3, 2008. 4) You informed me that the dog remains inside the fenced yard at all times it is not under your direct control; this is a satisfactory arrangement. Thank you for your cooperation in remedying this situation Eric! - Carrington Carrington Brown Pitkin County Code Enforcement 970-429-2814 970-379-6872 Nancy Mackenzie From: Nancy Mackenzie Sent: Tuesday, July 15, 2008 3:35 PM To: Carrington Brown Subject: RE: Notice of violation Eric 222 Bob Cat Attachments: CO for 2 bedrooms. png Carrington, Roger has brought up the issue that he contends, based on real estate ads, the house is actually a 3 bedroom, 2 bathroom house. The finaled ISDS permit stated the "permit is issued for 2 bedrooms. The unfinished basement/office room is not considered to be a potential bedroom." I went over to Tony at the Building Dept. Attached is the original CO for 2 bedrooms and an unfinished basement. The only other building permit since was to enclose a porch. How should we proceed? Nancy Nancy Mackenzie From: Eric Petterson [eric.petterson@starband.net] y p �(— O l / Sent: Wednesday, June 18, 2008 3:52 PM �� Z�'" 3 To: Carrington Brown Cc: Nancy Mackenzie; Joanna Schaffner; Lance Clarke Subject: RE: Notice of violation I agree with your summary as stated below, and agree to comply with those items. Thank you for your time and patience. I will keep you informed as to the progress in remedying those items. Eric Petterson Rocky Mountain Ecological Services, Inc. phone/fax: 970-963-2190 mobile: 970-309-4454 eric. Petterson (o)starband. net From: Carrington Brown [mailto:Carrington.Brown@co.pitkin.co. us] Sent: Wednesday, June 18, 2008 12:06 PM To: eric.petterson@starband.net Cc: Nancy Mackenzie; Joanna Schaffner; Lance Clarke Subject: Notice of violation Eric, Thank you for meeting with Nancy Mackenzie and me today at your property at 222 Bobcat. This e-mail's purpose is to summarize our observations and the next steps for you to take. 1) The driveway is at least partially on top of the septic field. You have agreed to establish the precise location of the septic field and then remove the gravel from on top of it and add grass in that area. You will also remove the shed that is located on top of the septic field and intend to remove the shed from the property entirely. Once this is completed please arrange for inspection with Nancy. This item #1 will be accomplished within 45 days from today, August 3, 2008. 2) You have agreed to make application for permits for the three sheds (two, assuming you remove the one shed mentioned in item #1), per my Notice of Violation, by July 15, 2008. Contact Joanna Schaffner of Pitkin County Community Development to deal with the permit requirement. This will be accomplished by July 15th, 2008. I�r r 3) You admitted that the picket fence is not located on your property as it passes along the road in front of your house and agreed to move it so it is on your property. In order to place it outside the development envelope you need to obtain a fence permit from Community Development (contact Joanna Schaffner 920-5105 for details) before moving the fence. This will be accomplished by August 3, 2008. 4) You informed me that the dog remains inside the fenced yard at all times it is not under your direct control; this is a satisfactory arrangement. Thank you for your cooperation in remedying this situation Eric! - Carrington Carrington Brown Pitkin County Code Enforcement 970-429-2814 970-379-6872 L Nancy Mackenzie From: Carrington Brown Sent: Wednesday, June 18, 2008 12:06 PM To: 'eric. petterson@starband. net' Cc: Nancy Mackenzie; Joanna Schaffner; Lance Clarke Subject: Notice of violation Follow Up Flag: Follow up Flag Status: Flagged Eric, Thank you for meeting with Nancy Mackenzie and me today at your property at 222 Bobcat. This e-mail's purpose is to summarize our observations and the next steps for you to take. 1) The driveway is at least partially on top of the septic field. You have agreed to establish the precise location of the septic field and then remove the gravel from on top of it and add grass in that area. You will also remove the shed that is located on top of the septic field and intend to remove the shed from the property entirely. Once this is completed please arrange for inspection with Nancy. This item #1 will be accomplished within 45 days from today, August 3, 2008. 2) You have agreed to make application for permits for the three sheds (two, assuming you remove the one shed mentioned in item #1), per my Notice of Violation, by July 15, 2008. Contact Joanna Schaffner of Pitkin County Community Development to deal with the permit requirement. This will be accomplished by July 15th, 2008. 3) You admitted that the picket fence is not located on your property as it passes along the road in front of your house and agreed to move it so it is on your property. In order to place it outside the development envelope you need to obtain a fence permit from Community Development (contact Joanna Schaffner 920-5105 for details) before moving the fence. This will be accomplished by August 3, 2008. 4) You informed me that the dog remains inside the fenced yard at all times it is not under your direct control; this is a satisfactory arrangement. Thank you for your cooperation in remedying this situation Eric! - Carrington Carrington Brown Pitkin County Code Enforcement 970-429-2814 970-379-6872 M Nancy Mackenzie From: Nancy Mackenzie Sent: Thursday, June 05, 2008 3:51 PM To: Carrington Brown Subject: RE: 222 Bobcat Ln M Hi Carrington, We have no permit on file for a field replacement. So that would be a good question to ask. We have on file permit # 98006 for the original. The as -built drawing shows the absorption bed is 15 ft wide and 40 ft long, parallel to South side of the property (right side of the driveway) and meeting the 10 ft setback from the property line. When I was out there it appeared that the sheds and possibly part of the driveway were now located over the absorption bed. Our regulations do not allow any type of `activity' or building on top of an absorption bed (or drywell, etc). You can ask him to stake out the absorption bed and if these other developments are on top of the bed, they must be removed and the area must be seeded with grass. — However if that absorption bed as been removed as is alleged..??? We can also ask him to prove what he has. From: Carrington Brown Sent: Thursday, June 05, 2008 12:28 PM To: Nancy Mackenzie Subject: 222 Bobcat Ln Hi Nancy, I am writing a NOV to Mr. Petterson of 222 Bobcat Lane for various violations of the Code. You and I discussed the status of his septic (I'm told that he replaced a field system recently and that it was not permitted, etc. and it is placed under his driveway.) I don't recall what we decided about the status of that septic system, what do you recall our deciding about this situation? Thanks -C Carrington Brown Pitkin County Code Enforcement 970-429-2814 970-379-6872 C; HEPWORTH-PAWLAK GEOTECHNICAL, INC. 5020 Road 154 Glenwood Springs, CO 81601 Fax 970 945-8454 Phone 970 945-7988 November 28, 1997 Glenn Harsh P.O. Box 1852 Glenwood Springs, Colorado 81602 Job No. 197 602 Subject: Subsoil Study for Foundation Design and Percolation Test, Proposed Residence, Lot E-11, Redstone Ranch Acres, Pitkin County, Colorado Dear Mr. Harsh: As requested, Hepworth-Pawlak Geotechnical, Inc. performed a subsoil study and percolation test for foundation and septic disposal designs at the subject site. The study was conducted in accordance with our agreement for geotechnical engineering services to you dated October 6, 1997. The data obtained and our recommendations based on the proposed construction and subsurface conditions encountered are presented in this report. Proposed Construction: The proposed residence will be a two story wood frame structure over a full basement. Basement floor will be slab -on -grade. Cut depths are expected to be up to about 8 feet. Foundation loadings for this type of construction are assumed to be relatively light and typical of the proposed type of construction. The septic disposal system is proposed to be located about 35 feet to the east of the center of the building envelope. If building conditions or foundation loadings are significantly different from those described above, we should be notified to re-evaluate the recommendations presented in this report. Site Conditions: The site was vacant and covered with about 1 foot of snow at the time of our field work. The ground surface is relatively flat with a slight slope down to the southwest. There is a very steep slope down to Kline Creek to the north of the building area. The lot is vegetated with tall aspen and evergreen trees, grass and weeds. Subsurface Conditions: The subsurface conditions at the site were evaluated by excavating one exploratory pit in the building area and one profile pit in the septic disposal area at the approximate locations shown on Fig. 1. The logs of the pits are presented on Fig. 2. The subsoils encountered, below about 1 foot of topsoil, consist of 1 to 11/2 feet of silty to clayey sand and sandy clay overlying relatively dense sandy gravel with cobbles and boulders. Results of swell -consolidation testing performed on a relatively undisturbed sample of sandy clay, presented on Fig. 3, indicate moderate to relatively high compressibility under conditions of loading and wetting. Results of a gradation analysis performed on a sample of the gravel (minus 5 inch fraction) obtained Glenn Harsh November 28, 1997 Page 2 from the site are presented on Fig. 4. The laboratory testing is summarized on Table I. Perched groundwater was observed seeping into Pit 1 at a depth of 51h feet at the time of excavation and the soils were moist to wet below water level. Foundation Recommendations: Considering the subsoil conditions encountered in the exploratory pits and the nature of the proposed construction, we recommend spread footings placed on the undisturbed natural gravels designed for an allowable soil bearing pressure of 3,000 psf for support of the proposed residence. Due to the perched shallow groundwater encountered in the building area, excavation dewatering may be needed for construction of the basement. Footings should be a minimum width of 16 inches for continuous walls and 2 feet for columns. Loose and disturbed soils encountered at the foundation bearing level within the excavation should be removed and the footing bearing level extended down to the undisturbed natural gravels. Exterior footings should be provided with adequate cover above their bearing elevations for frost protection. Placement of footings at least 42 inches below the exterior grade is typically used in this area. Continuous foundation walls should be reinforced top and bottom to span local anomalies such as by assuming an unsupported length of at least 10 feet. Foundation walls acting as retaining structures should be designed to resist a lateral earth pressure based on an equivalent fluid unit weight of at least 45 pcf for the on-site sand and gravel as backfill, excluding topsoil and oversized rock. Floor Slabs: The natural on-site soils, exclusive of topsoil, are suitable to support lightly loaded slab -on -grade construction. The upper silty to clayey sand soils are compressible upon loading. To reduce the effects of some differential movement, floor slabs should be separated from all bearing walls and columns with expansion joints which allow unrestrained vertical movement. Floor slab control joints should be used to reduce damage due to shrinkage cracking. The requirements for joint spacing and slab reinforcement should be established by the designer based on experience and the intended slab use. A minimum 4 inch layer of free -draining gravel should be placed beneath basement level slabs to facilitate drainage. This material should consist of minus 2 inch aggregate with less than 50 % passing the No. 4 sieve and less than 2 % passing the No. 200 sieve. All fill materials for support of floor slabs should be compacted to at least 95 % of maximum standard Proctor density at a moisture content near optimum. Required fill can consist of the on-site soils devoid of vegetation, topsoil and oversized rock. Underdrain System: Free water was encountered above the anticipated building excavation depth during our exploration. It has been our experience in mountainous areas that local perched groundwater can develop and groundwater levels can rise during times of heavy precipitation or seasonal runoff. Frozen ground during spring H -P GEOTECH Glenn Harsh November 28, 1997 Page 3 runoff can create a perched condition. We recommend below -grade construction, such as retaining walls and basement areas, be protected from wetting and hydrostatic pressure buildup by an underdrain system. The drains should consist of drainpipe placed in the bottom of the wall backfill surrounded above the invert level with free -draining granular material. The drain should be placed at each level of excavation and at least 1 foot below lowest adjacent finish grade and sloped at a minimum 1 % to a suitable gravity outlet. Free -draining granular material used in the underdrain system should contain less than 2% passing the No. 200 sieve, less than 50 % passing the No. 4 sieve and have a maximum size of 2 inches. The drain gravel backfill should be at least 11/2 feet deep. Surface Drainage: The following drainage precautions should be observed during construction and maintained at all times after the residence has been completed: 1) Inundation of the foundation excavations and underslab areas should be avoided during construction. 2) Exterior backfill should be adjusted to near optimum moisture and compacted to at least 95 % of the maximum standard Proctor density in pavement and slab areas and to at least 90% of the maximum standard Proctor density in landscape areas. Free -draining wall backfill should be capped with about 2 feet of the on-site, finer graded soils to reduce surface water infiltration. 3) The ground surface surrounding the exterior of the building should be sloped to drain away from the foundation in all directions. We recommend a minimum slope of 6 inches in the first 10 feet in unpaved areas and a minimum slope of 3 inches in the first 10 feet in pavement and walkway areas. 4) Roof downspouts and drains should discharge well beyond the limits of all backfill. Percolation Testing: Percolation tests were conducted October 30, 1997 to evaluate the feasibility of an infiltration septic disposal system at the site. One profile pit and three percolation holes were dug at the locations shown on Fig. 1. The test holes (nominal 12 inch diameter by 12 inch deep) were hand dug at the bottom of shallow backhoe pits and were soaked with water one day prior to testing. The soils exposed in the percolation holes are similar to those exposed in the Profile Pit shown on Fig. 2 and consist of 1 foot of topsoil and 1 foot of silty to clayey sand overlying sandy gravel with cobbles and boulders. The percolation test results are presented in Table II. The percolation test results indicate an infiltration rate of between 30 and 60 minutes per inch with an average of 40 minutes per inch. The percolation rates were based on the last two readings of the test. Based on the subsurface conditions encountered and the percolation test results, the tested area should be suitable for a conventional infiltration H -V UEOTECH Glenn Harsh November 28, 1997 Page 4 septic disposal system. The system should be based in the sandy gravel soils beneath the topsoil and upper clayey sands. Limitations: This study has been conducted in accordance with generally accepted geotechnical engineering principles and practices in this area at this time. We make no warranty either expressed or implied. The conclusions and recommendations submitted in this report are based upon the data obtained from the exploratory pits excavated at the locations indicated on Fig. 1, the proposed type of construction and our experience in the area. Our findings include interpolation and extrapolation of the subsurface conditions identified at the exploratory pits and variations in the subsurface conditions may not become evident until excavation is performed. If conditions encountered during construction appear different from those described in this report, we should be notified at once so re-evaluation of the recommendations may be made. This report has been prepared for the exclusive use by our client for design purposes. We are not responsible for technical interpretations by others of our information. As the project evolves, we should provide continued consultation and field services during construction to review and monitor the implementation of our recommendations, and to verify that the recommendations have been appropriately interpreted. Significant design changes may require additional analysis or modifications to the recommendations presented herein. We recommend on-site observation of excavations and foundation bearing strata and testing of structural fill by a representative of the geotechnical engineer. If you have any questions or if we may be of further assistance, please let us know. Sincerely, Jordy Z. Reviewed By WLAK taniel E. Hardin, P. JZA/kmk attachments ;CI INC. R ' N ADq,S. 2970% err 4 H -P GEOTECH W Z Q J U m 0 m NOT TO SCALE BOBCAT LANE 197 602 DOWN I PIT 1 ■ I CENTER OF BUILDING ENVELOPE STAKE I 35' Iw IC V j Y W a- W UJ uj P 1 P 2 I Nz 0 r� PROFILE I Yo PIT oZ 3 I O CATION OF PROPOSED PTIC DISPOSAL AREA I STAKED IN FIELD I NOTE: DRAWING PREPARED FROM FIELD SKETCH. HEPWORTH - PAWLAK I LOCATION OF EXPLORATORY PITS Fig. 1 GEOTECHNICAL, INC. AND PERCOLATION TEST HOLES NOTES: 1. Exploratory pits were excavated on October 29, 1997 with a backhoe. 2. Locations of exploratory pits were measured approximately by pacing from features on the site Plan Provided. 3. Elevations of exploratory pits were not measured and logs of exploratory pits are drawn to depth. 4. The exploratory pit locations should be considered accurate only to the degree implied by the method used. 5. The lines between materials shown on the exploratory pit logs represent the approximate boundaries between material types and transitions may be gradual. 6. Water level readings shown on the logs were made at the time and under the conditions indicated. Fluctuations in water level may occur with time. 7. Laboratory Testing Results: WC = Water Content ( % ) DD = Dry Density ( pcf ) +4 = Percent retained on No. 4 sieve —200 = Percent passing No. 200 sieve 197 602 HEPWORTH - PAWLAK LOGS OF EXPLORATORY PITS Fig. 2 GEOTECHNICAL, INC. PROFILE PIT PIT 1 0 0 WC=20.3 DD=101 -200=58 a o•; ao. -.- 4. 5 5 C WC=4.5 +4=67 -200=6 i 1010 • 9.e • LEGEND: TOPSOIL; slightly sandy clayey silt, organic, roots, occasional gravel, medium dense, very moist, block. SAND (SM—SC); silty, clayey to sandy clay, scattered gravel, medium dense to stiff, moist to very moist reddish brown. 1. GRAVEL (GP—GM); sandy, slightly silty, scattered to frequent cobbles and boulders, dense, H., moist, reddish brown, rounded rock. 2" Diameter hand driven liner sample. Disturbed bulk sample. _J _ Free water level in pit at the time of excavation. NOTES: 1. Exploratory pits were excavated on October 29, 1997 with a backhoe. 2. Locations of exploratory pits were measured approximately by pacing from features on the site Plan Provided. 3. Elevations of exploratory pits were not measured and logs of exploratory pits are drawn to depth. 4. The exploratory pit locations should be considered accurate only to the degree implied by the method used. 5. The lines between materials shown on the exploratory pit logs represent the approximate boundaries between material types and transitions may be gradual. 6. Water level readings shown on the logs were made at the time and under the conditions indicated. Fluctuations in water level may occur with time. 7. Laboratory Testing Results: WC = Water Content ( % ) DD = Dry Density ( pcf ) +4 = Percent retained on No. 4 sieve —200 = Percent passing No. 200 sieve 197 602 HEPWORTH - PAWLAK LOGS OF EXPLORATORY PITS Fig. 2 GEOTECHNICAL, INC. 0 Moisture Content = 20.3 percent Dry Density Weight = 101 pcf Sample of: Sandy Clay From: Pit 2 at 1 Foot 1 2 ° V) Compression upon wetting 0) 3 a E 0 U 4 5 I i 6 I 7 I i 0.1 1.0 10 100 APPLIED PRESSURE — ksf, 197 602 HEPWORTH - PAWLAK GEOTECHNICAL, INC. SWELL-CONSOLIDATION TEST RESULTS Fig. 3 r�r�•�i.r_r�+���s.��r�r��_��_��_�••�.a_�_r1..rr•._� A=CC ow M Fill VW ��r.���ia�•������������mmwll Mol ffm� Em HEPWORTH PAWLAK GRADATIONTEST RESULTS• • ECHNICAL, INC- W F- J D U) W U) w a� cv M a � 6 H O CO � U � O O CC (U m (� N O U L � � LO N W OW > x z W z O `a G n zf N o � U x ~ J ? � J a cc cc fL 5 ❑ F J J Z 2 U W 00 W Q Q N a a � z a N � Q Q 6 J Y r O Z c O Q 0 2 r W ~ w Lq M y Z O a o o N z f v co x _ r m O a U O J W J i Q N S HEPWORTH-PAWLAK GEOTECHNICAL, INC. TABLE II PERCOLATION TEST RESULTS JOB NO. 197 602 HOLE NO. HOLE DEPTH (INCHES) LENGTH OF INTERVAL (MIN) WATER DEPTH AT START OF INTERVAL (INCHES) WATER DEPTH AT END OF INTERVAL (INCHES) DROP IN WATER LEVEL (INCHES) AVERAGE PERCOLATION RATE (MIN./INCH) P-1 51 1/2 15 water added 7 1/4 6 1/2 3/4 60 6 1/2 61/4 1/4 61/4 6 1/4 6 3/4 6 1/2 1/4 6 1/2 61/4 1/4 6 1/4 6 1/4 P-2 54 1/2 15 water added water added 8 6 2 30 7 1/2 6 1/2 1 6 1/2 6 1/2 6 53/4 1/4 9 3/4 7 23/4 7 6 112 1/2 6 1/2 6 1/2 P-3 51 1/2 15 water added water added 8 1/2 53/4 23/4 30 7 1/2 5 1/2 2 8 7 1/2 1/2 7 1/2 6 1/2 1/2 6 1/2 6 1/2 6 5 1/2 1/2 NOTE: Percolation test holes were hand dug in the bottom of shallow backhoe pits on October 29, 1997. The holes were protected from freezing overnight with rigid foam insulation. Percolation tests were conducted on October 30, 1997. Form No. GWS -25 APPLICANT OFFICE OF TH; TATE ENGINEER COLORADO DIVISION OF WATER RESOURCES 818 Centennial Bldg., 1313 Sherman St., Denver, Colorado 80203 (303) 866-3581 GLENN M HARSH 810 LINCOLN AVE GLNWD SPRNG CO 81601- (970) 928-7824 PERMIT TO CONSTRUCT A WELL WELL PERMIT NUMBER 2!1,4537 - - DIV. 5 CNTY. 49 WD 38 DES. BASIN MD Lot: Block: Filing: Subdiv: LIC APPROVED WELL LOCATION PITKIN COUNTY SW 1/4 NE 1/4 Section 16 Twp 9 S RANGE 88 W 6th P.M. DISTANCES FROM SECTION LINES 3390 Ft, from South Section Line 3000 Ft. from West Section Line ISSUANCE OF THIS PERMIT DOES NOT CONFER A WATER RIGHT CONDITIONS OF APPROVAL 1) This well shall be used in such a way as to cause no material injury to existing water rights. The issuance of the permit does not assure the applicant that no injury will occur to another vested water right or preclude another owner of a vested water right from seeking relief in a civil court action. 2) The construction of this well shall be in compliance with the Water Well Construction Rules 2 CCR 402-2, unless approval of a variance has been granted by the State Board of Examiners of Water Well Construction and Pump Installation Contractors in accordance with Rule 18. 3) Approved pursuant to CRS 37-92-602(3)(b)(II)(A) as the only well on a residential site of 3.117 acres described as that portion of the SW 1/4, NE 1/4, Sec. 16, Twp. 9 S, Rng. 88 W, 6th P.M., Pitkin County, more particularly described on attached exhibit A. 4) The use of ground water from this well is limited to ordinary household purposes inside a single family dwelling. The ground water shall not be used for irrigation or other purposes. 5) The maximum pumping rate shall not exceed 15 GPM. 6) The return flow from the use of this well must be through an individual waste water disposal system of the non -evaporative type where the water is returned to the same stream system in which the well is located. 7) This well shall be constructed not more than 200 feet from the location specified on this permit. 8) This permit has been approved with the following change(s): Approved at a point 3390 feet from the south section line and 3000 feet from the west section line of Sec. 16, Twp. 9 S, Rng.88 W, 6th P.M.. You are hereby notified that you have the right to appeal the issuance of this permit, by filing a written request with this office within sixty (60) days of the date of issuance, pursuant to the State Administrative Procedures Act. (See Section 24-4-104 through 106, C.R.S.). NOTE: Expired permit 152655, was previously issued for this lot. (ASAP VED XV Z . State Engireer DEC 0 3 1998 Receipt No. 0438098 DATE ISSUED BY EXPIRATION DATE DEC 0 3 2000 �t COLORADO DIVISION OF`, fER RESOURCES ft&VEL )EPARTMENT OF NATURAL RESOURCES 1313'SHERMAN ST., RM. 818, DENVER CO 80203 �OV �9�8 phone - info: (303) 866-3587 main: (303) 866-3581 '2 RESIDENTIAL* (Note: You may also use this forth to apply for livestock watering) Water Well t'�►ppiieation Review instructions prior to completing form Must be complete j.illlc�C ink or ed 1. APPLICANT INFORMATION 6. USE OF WELL (check appropriate entry or entries) Name of applicant See instructions to determine use(s) for which you may qualify -- J J 1 let%,i 41- Pa/ 5 IM A. Ordinary household use in one single-family dwelling (NO outside use) Merin, Address ❑ B. Ordinary household use in 1 to 3 single-family p��%/iGal�✓e- dwellings: Number of dwellings: 13 Home garden/lawn irrigation, not to exceed 1 acre: 13 area irrigated 13sq. ft. ❑ acre city 1 r State (?16 �7lP�lwcxf r S �n O 160 Telephone Number (include ar code) 770- 9a - 8a 13 Domestic animal watering -- (non-commercial) 2. TYPE OF APPLICATION (check applicable box(es)) ❑ C. Livestock watering (on farm/ranch/range/pasture) ❑ Construct new well ❑ Use existing well 7. WELL DATA Maximum pumping rete 5-10 gprn Annual amount to be witlWrewn X3acre-feet ❑ Replace existing well ❑ Change / Increase Use ❑ Change (source) aquifer IN Reapplication(expired permit) ❑ Other: Total depth R 00 feet Aquifer s1nlG - Su; are 41 3. REFER TO (if applicable): Water court case # /%,4 Permit if 15-2 6 5S 8. TYPE OF RESIDENTIAL SEWAGE SYSTEM ® Septic tank / absorption leach field Verbal # /, W -VE- Monitoring hole acknowledgment 4 MH- sf/ ❑ Central system District name: ❑ Vault Location sewage to be hauled to: Well name or i 4. LOCATION OF WELL ❑ Other (attach copy of engineering design) Counl�y f�j.��J 1L / % ! i j lli Quaa tarigW luarter 5 %. Quarter N " " c- Y4 9. PROPOSED WELL DRILLER (optional) NameLicense Z—/ /'- number Section /6 Township N or S I �' ❑ 51 Range E or W p g ❑ ® Principal Meridian 6 10. SIGNATURE of applicant(s) or authorized agent 9-4 Distance of well from section linesThe ft. from 13N E3S 400-0 ft. from ❑ E ❑ w making of false statements herein constitutes perjury in the second degree, which is punishable as a class 1 mis- demeanor pursuant to C.R.S. 24-4-104(13)(a). I have read the statements herein, know the contents thereof and state wdl location address, if different from applicant address Gf applicable) /1O _51rftl 04ieSS 4— 5e�_- / cleSe-_ that they are true to my knowledge. For replacement wells only - distance and direction from old well to well Must feet direction 5. TRACT ON WHICH WELL WILL BE LOCATED A. You must check one of the following - see instructons, ❑ Subdivision: Name Title y Ljt4� Pa -'J Date OPTIONAL INFORMATION Lot no. Block no. Filing/Unit uses map name DwR map no. Surface elev. ❑ County exemption (attach copy of county approval & survey) Name/no. Tract no. Office use only )` h� 4� 9� ✓l`•eWU DIV �J ❑ Mining claim tattach copy of deed or survey) Name/no. ® Other (attach legal description to applications CO S. STATE PARCEL ID# (optional): .t (,';tWD DO uEui;u TH438098 1111-291.86 *(tl; tlr � r^ �) "�� #�fflER i~i_aQtut� C. Macrae in tract D. Are you the owner of tfiis property? j OYES ®NO ('rf no - see detailed shat.) BA E. Will this be the only well on this tract? ®YES ❑ NO (if other wells are on this tract - see detailed inst.) USE Mfg Form GWS -44 (I V95) M .. . EXHIBIT A BEGINNING AT A POINT FROM WHICH THE SOUTHWEST CORNER OF THE SW1/4NE1/4 OF SECTION 16, TOWNSHIP 9 SOUTH, RANGE 88 WEST OF THE 6TH P.M. BEARS SOUTH 233.54 FEET; THENCE NORTH 10.86.03 FEET TO THE NW CORNER OF SWI/4NE1/4, SECTION 16; THENCE EAST 356.40 FEET TO THE INTERSECTI'ON WITH THE WEST RIGHT OF WAY LINE OF COLORADO HIGHWAY NO. 133; THENCE ALONG SAID RIGHT OF WAY LINE SOUTH 42 DEGREES 12120" WEST 42.77 FEET; THENCE ALONG THE ARC OF A CL`�ti JE 365.80 FEET, WHOSE CHORD BEARS SOUTH 27 DEGREES 52'20" WEST 363.80 FEET; THENCE SOUTH 13 DEGREES 36120" WEST 206.10 FEET TO THE HIGHWAY RIGHT OF WAY MONUMENT; THENCE SOUTH 11 DEGREES, 34'50" WEST 543.50 FEET TO THE POINT OF BEGINNING. i" COUNTY OF PITKIN STATE OF COLORADO ALDERMAN PROPERTY 0 WELL CONSTRUCTION AND TEST REPORT STATE OF COLORADO, OFFICE OF THE STATE ENGINEER WELL PERMIT NUMBER 214537 FOR OFFICE USE ONLY IVO RECEIVED AUG 0 4 2000 �STATF ENG�N6E��J ccxo. ; APPROVAL * OW331-81-03 2. Owner Name(s) GIenn M. Harsh Mailing Address : 0222 Bobcat Lane City, St Zip: Redstone, Co. 81623 Phone (960) 963-0772 3. WELL LocATON AS MILLED- SW 114 NE DISTANCES FROM SEC. LINES: 2020 ft. from North Sec, line. and SUBDIVISION: STREET ADDRESS AT WELL LOCATION: 114 Sec, 16 Twp, 09S Range 88W 2600 ft. from East Sec. line. OR LOT BLOCK FILING(UNIT) 4 GROUND SWAACE ELEVATION ft. DRILLINd METHOD Air Rotary DATE COMPLETED 06113/00 TOTAL DEPTH 58 ft, DEPTH COMPLETED 58 ft. 5. GEOLOGIC LOG 8. HOLE DIAM_ 1in1 FROM 1111 TO (t) Depth Type of Material (Size, Color, and Type) 9.0 0 58 000-058 Rocks, Dirt, Gravels 7. PLAIN CASING OD (In) Kind Wall &n From (ft) To (ft) 7.0 Steel 0.240 -1 48 PERF. CASING, Screen Slot Size: 7.0 teal .240 48 68 -- WATER LOCATED : 25 + REMARKS 8. Filter Pack Material: Size: Interval ; 9. Packer lacempnt Type ; Depth ; 10. GROUTING RECORD meliertal Amount Dan" Irmordal Placement cement 3 sks 16 gal 10-25 poured 11. DISINFECTION: Type : HTH Amt. Used: 2 oz. 12. WELL TEST DATA : [ ] Check Box If Test Data is Submitted On Supplemental Form. TESTING METHOD., Air Compressor Static Level : 25 ft. Date/Time Measured : 06/13/2000 Production Rate : 15 gpm. Pumping Level . Total ft. Date/Time Measured : 06/1312000 Test Length : 2 hrs. Remarks ■m true bo my mmdpe. Q'~rd to Se n (e) the roeldw vT 6 etatemenb conwLetit 1 I ria dw stenmeets ma ro n e w the e mffte ttt mO, end iQ theyea per)my in the "ono o"r" end b puntthable is ■ chm 1 mlederneanor.) CONTRACTOR : Shelton Drillin Corp. Phone : (970 927-4182 Lir- No 1095 Name 1 Title (Please Type or Print) Wayne Shelton I President Signat��� Date 06116100 I ORIGINAL FORM No. STATE OF COLORADO "542 OFFICE OF THE STATE ENGINEER W 818 Centennial Bldg-, 1313 Shemun St., Denver, Colorado 50243 �fr (303) 8883581 Far Office Use only CEIVEU PRIOR TO COMPLETING FORM, SEE INSTRUCTIONS ON REVERSE SIDE 1. APPLIGATION FOR WELL LOCATION AMENDMENTUL 17 2000 WELL PERMIT NUMBER oC l 'A � � � WAr res Rt:��u5 SI TE tNr,Ir�EEfi ............................... .. COLO 2. WELL OWNER NAME(S) ..-. .. ........... .................................------.--...,,..,.,...,.,..,..,..,.,..,,............_..............__.._,..,..,. Mailing Address a2g��54 C St Zi CAD 9 A P A City, p.. .................%................._.........................,........,,,..,.......---------..........--.---...... Phone (., 'd ) f°.' .. ......C).77. 12M ME waWFNWcor) .^L_CNG;rgi.r1 .. aR r+%rm *jk;#1 OWNER'S WELL DESIGNATION 3. ACTUAL WELL LOCATION: COUNTY ........ ......................................... .............................. .... ................ (Address at well locafion) (CRY) Staa 114 of th, _6?F.114, Sec. ......`-,..1.•. Twp,--•/ ..... ......... , Range .,.., g.........,. ........ ,. .............. P.M. (North or South (East or We" Distances from Section Lines Ft. from Section Line 2,(o00 Ft from � .-.-._. Section Line. .................................. ..--.......... �. (North yr Booth) (East or Waq Subdlvlslon Lot Block Filing (Unlf) 4. The location of the existing well needs to be amended for the foilowing reason(s): (Attach appropriate documentation as necessa -.....' ........................................................................ .................... 5. 1 (we), the above listed owners) own the well desCiibed herein. I (we) have read the statements made herein, know the contents thereof, and state that they are true to my (our) knowledge. [Pursuant to Section 24-4-104 (13)(a) C.R.S., the making of false statements herein constitutes perjury in the second degree and is punishable as a class 1 misdemeanor.] NamelTltle (Please type or print) - Signature -7 Date (M. .��. M. I APPROVED FOR A CORRECTKaN oFOLOCATI�N Pt i ONLY Topo= MEMMNDUM 03.1 DATED JULY 1, 1903 .............................................------ nam 9tace Er�in+er Court Case No ................................... Div. Co. �%t... IND.-..... Basin MD ............... 040.,11 1- - %Not 11"W ADMINISTRATIVE DECISION OF THE COMMUNITY DEVELOPMENT DIRECTOR OF PITKIN COUNTY, COLORADO, AMENDING THE HARSH 1041 HAZARD REVIEW Administrative Decision Nd?Z 2002 RECITALS 1. Pursuant to Section 3-200.80 of the Land Use Code, Glen Harsh ("Applicant") has applied to the Community Development Director of Pitkin County, Colorado ("Director"), to expand the approved building envelope to extend to the top of the bank to the northeast of the existing residence in order to accommodate a porch and a garage. 2. The Applicant's lot is zoned AFR 10 and contains 0.45 acres. 3. The property is located on Bobcat Lane, and is described as Lot E-11, Redstone Ranch Acres Subdivision No. 3. 4. The Hearing Officer granted 1041 Hazard Review and Conceptual Submission approval on March 27, 1998, and the 1041 site plan was recorded in Plat Book 44 at Page 15. An amendment to allow the septic system to be located outside of the approved building envelope was approved by an Administrative Decision approved by the Director on April 6, 1998. 5. The approved building envelope was set back 10 feet from the top of bank as requested by the Colorado State Forest Service to mitigate for wildfire hazard concerns, given the fuel density and steepness of the adjacent slope. The Colorado State Forest Service has reviewed and supports the proposed expansion of the envelope, subject to the wildfire mitigation measures specified in the original approval. The Director finds the request is consistent with the requirements of the Code. THE DIRECTOR DOES HEREBY APPROVE an amendment to the Harsh 1041 Site Plan recorded in Plat Book 44 at Page 15 as shown on Exhibit A. Prior to submission of any building permit applications for the garage or porch, the Applicant shall submit an amended 1041 Hazard Review Site Plan to the Community Development Department for approval and recording. The site plan shall also be submitted in digital format for integration into the County's GIS system. The mylar copy of the site plan must be signed by the owner prior to submittal for recording. All other conditions of approval shall remain in full force and effect. APPROVED by the Director, this 6A�, day of 4�vtA,_, 2002. CLI , c-0, Cindy Houben, Community Development Director j>iD a-7aq- a93- 0y -CEJ ea5e -## t�103 S -17a? 484849 039/08/2002 10:069 SILVIA DAVIS PITKIN COUNTY CO R 0.00 D 0.00 L . 2376 ', LOT -. 0. 95 4C. •,- m o N � O `(S �+ p B N N � � v m ct a a C I m A s a o�C O F C" xis �in �' DE w 17H - • [ s r _ R ABOVe /rllf U Jill• MMMM� F'- or \ dr�tlo Ar.. L.S. 14111 OGI, fil % cr \ p v. . 0., �i =2 Bant rebar SC:q�e-�•A I 'I 0 C-l�r✓v�n I��. t�f� �1 ��L�S'Wn� r�C1tiGN ►-rGP'eS G>n _Gi? - /n'7 "7 0 0 MEMORANDUM TO: Pitkin County Hearing Officer FROM: Suzanne Wolff, Community Development Department RE: Wall 1041 Hazard Review & Conceptual Submission DATE: March 27, 1997 REQUEST: The applicant requests 1041 Hazard Review and Conceptual Submission approval for construction of a single family residence. The property is impacted by the following hazards: • Mapped elk winter range; mapped within 1/4 mile of elk critical habitat, winter concentration area, and severe winter range; mapped bighorn sheep habitat across Hawk Creek and southeast above the subdivision • Medium and severe wildfire hazard; • Mapped alluvial fan; • Slopes of greater than 15%. APPLICANT: Michael Wall REPRESENTATIVE: Rhonda Bazil LOCATION: Lot E-11, Redstone Ranch Acres Subdivision No. 3; Bobcat Lane ZONING/LOT SIZE: The property is zoned AFR-10 and contains 0.45 acres, therefore, it is nonconforming with respect to size. SITE DESCRIPTION: The building envelope is located on a flat bench adjacent to Bobcat Lane. The lot drops steeply down to Kline Creek below the bench. The vegetation on the lot includes ponderosa pine, aspen and spruce. ACCESS: Access from Highway 133 is provided via Antelope Lane and Bobcat Lane. REFERRAL COMMENTS: Comments are attached as Exhibit B, and are incorporated throughout this memorandum. STAFF COMMENTS 1041 HAZARD REVIEW Wildfire: The property is mapped in a low wildfire area. Vince Urbina of the Colorado State Forest Service visited the site and rated the hazard as severe, because of the existing fuel density. Mr. Urbina clarified that the hazard within the building envelope would be rated as medium if the envelope was set back from the top of slope, since the upper bench is flat and the vegetation is less dense. The applicant 1 O �D subsequently agreed to relocate the envelope, and staff forwarded the application to the Hearing Officer for review, since a full 1041 review was no longer required. Urbina states that the hazard can be mitigated by implementing the following defensible space measures: Establish and maintain a clear 10 foot perimeter where vegetation can be maintained at 6 inches or less. No woody vegetation should be planted within this perimeter, and firewood or other combustible materials shall be stored outside of this perimeter. Thin the trees within a 30' perimeter around all structures, which includes the trees on the embankment. Remaining trees shall have a minimum of 10 feet between the edges of the tree crowns, and the lower limbs of these trees shall be removed to a height of 10 feet to eliminate ladder fuels. Remove all deadfall material within 100 feet. Bill Gavette of the Carbondale and Rural Fire Protection District adds that access to the property is generally adequate via Bobcat Lane, however, "a short section of Bobcat Lane is quite steep in grade and could make access difficult under some weather conditions". Mr. Urbina notes that the road does not have dual access/egress and has woody vegetation along both sides of the road, which should be thinned. The applicant will be required to comply with the mitigation standards in Section 3-80.70(C). Wildlife: The property is within mapped elk winter range, and is adjacent to mapped elk winter concentration area, severe winter range and critical habitat, and is also adjacent to mapped bighorn sheep winter range, summer range, and overall range. Kevin Wright of the Division of Wildlife states that the parcel is adjacent to elk and bighorn sheep winter range, but there is little use within the subdivision due to existing disturbance and homes. Wright notes that the riparian habitat along Kline Creek is valuable to a variety of species and that the large ponderosa pine provides valuable perch sites for large raptors/owls. Wright recommends that the residence be set back from the top of the slope to limit bank erosion and to preserve the riparian area, and recommends the following mitigation measures: • Only one dog is permitted on the property, and the dog shall be kenneled. The kennel shall be constructed prior to issuance of a Certificate of Occupancy. • Maintain native vegetation outside the building envelope, particularly the large ponderosa pine along the creek. • The residence shall not extend over the steep embankment down to the creek. • All trash/garbage shall be kept in approved bear proof garbage containers. Michael Villa, Pitkin County's Wildlife Biologist, agrees with Mr. Wright's recommendations. Geologic: The property contains slopes in excess of 30% and is within a mapped alluvial fan, however, the building envelope is located on a flat bench and is not affected by debris flow. Nicholas Lampiris recommends site specific soils investigations, which should include a setback from the top of slope, and positive landscaping to conduct surface water away from the site. Summary: Based on the referral comments, and in order to lessen the potential fire hazard, to limit bank erosion and to preserve the riparian area, staff recommends and the applicant has agreed to set the envelope 10 feet back from the top of slope. To maintain the size of the envelope, this shift will locate the envelope F) N within the required 30 foot front yard setback. Roger Sherman, owner of the adjacent lot E-3, notes that the buildable area is extremely narrow and that he would like the residence to be located as far back on the lot as possible to reduce the impact of the residence on the road and the neighbors. Mr. Sherman's letter is attached as Exhibit C. However, staff supports the encroachment of the building envelope into the setback in order to locate the residence in the safest possible location. A variance from the Board of Adjustment will be required for any structure within the required setback; the well and septic system must both be located within the building envelope, but may encroach into the setback without a variance. CONCEPTUAL SUBNIISSION Water & Sewer: The applicant has drilled a well and proposes to install a septic system. The location of the well is not shown on the site plan. Mary Wood, Environmental Health Officer, notes that the well and the septic system must be located within the building envelope, and that it appears that the well is outside of the envelope. If the well is adjacent to the building envelope, staff recommends amending the envelope to include the well; otherwise, staff will allow the well to be located outside of the envelope. The leach field must be located a minimum of 100 feet from their well and from any neighboring wells, and must also comply with the required setbacks from any surface water or ground water, including Kline Creek. The type and size of the septic system will be determined by site specific soil data and the size of the home and the number of bedrooms. Ms. Wood recommends that an area of undisturbed soil be maintained between the leach field and the top of slope. Parkin : The applicant is required to provide two off-street parking spaces. Mr. Sherman is concerned that two spaces are not adequate since Bobcat Lane is not wide enough to accommodate parking on the side of the road. RECOMMENDATION: Staff recommends that the Hearing Officer approve the Wall 1041 Hazard Review and Conceptual Submission, subject to the following conditions: The applicant shall submit an amended site plan to the Community Development Department for recording, prior to submission of any building permit applications. The site plan shall also be submitted in digital format for integration into the County's GIS system. The site plan shall be modified as follows: A) Amend the signature block for the Pitkin County Hearing Officer. B) The building envelope shall be amended on the site plan to be set back 10 feet from the top of bank and 20 feet from the front property line. The well location shall be shown on the site plan. C) Include the following 1041 hazard waiver on the site plan: "Applicant acknowledges that he/she has been informed by Pitkin County of the existence of 1041 environmental hazard areas that might affect the property, any improvements, and the use and occupancy thereof." D) All conditions of approval shall be noted on the site plan. 2. A variance from the Board of Adjustment will be required for any structure within the required setback. Prior to issuance of a septic permit, the applicants shall provide documentation to the Environmental Health Department as to the location of the well, its compliance with the setback 0 �D requirements, and the quantity/quality of the water. The well must be located within the building envelope, unless the Environmental Health and Community Development Departments approve a location outside of the envelope. 4. A septic permit shall be obtained from the Environmental Health Department, prior to issuance of a building permit. The septic system must be located within the building envelope and must comply with the setback requirements from surface and groundwater sources. A fireplace/woodstove permit shall be approved by the Environmental Health Department prior to issuance of a building permit. 6. The applicant shall comply with the following landscaping and wildfire defensible space mitigation standards: A) Brush, debris, and non -ornamental vegetation shall be removed within a minimum 10 foot perimeter around the structure. B) Vegetation shall be reduced to break up the vertical and horizontal continuity of the fuels a minimum of a 30 foot perimeter around the structure, which includes the trees located on the embankment. However, the ponderosa pines on the embankment shall not be removed. C) Spacing between clumps of brush and vegetation within the 30 foot perimeters shall be a minimum of two times the height of the fuel. Maximum diameter of the clumps shall not exceed 10 feet. All measurements shall be from the edges of the crowns of the fuel. D) All branches from trees and brush within the 30 foot perimeter shall be pruned to a height of 10 feet above the ground and ladder fuels from around trees and brush shall be removed. E) Tree crown separation within the 30 foot perimeters shall have a minimum of 10 feet between the edges of the crowns. F) All branches which extend over the roof eaves shall be trimmed and all branches within 15 feet of the chimneys shall be removed. G) The density of fuels within a 100 foot perimeter of the structure shall be reduced. H) All deadfall within the 100 foot perimeter shall be removed. I) Low vegetation shall be maintained within a 10 foot perimeter around all structures. J) The applicant shall be responsible for the continued maintenance of the defensible space vegetation requirements. 7. The applicant shall comply with the following additional wildfire mitigation standards: A) The building envelope shall not be located in draws, canyons or on slopes greater than 30%. B) Roof construction shall be Class A, non-combustible material with no flat roofs. C) Vents shall be screened with corrosive resistant wire mesh with mesh'/4 inch maximun. D) Roofs and gutters shall be kept clear of debris. E) Yards shall be kept clear of all litter, slash, and flammable debris. F) All flammable materials shall be stored on a parallel contour a minimum of 15 feet away from any structure. G) Weeds and grasses within the 10 foot perimeter shall be maintained to a height not more than 6 inches. H) Firewood/wood piles shall be stacked on a parallel contour a minimum of 15 feet away from the structure. 4 10"IN I) Swimming pools shall be accessible to Fire Department vehicles. J) Fences shall be kept clear of brush and debris. K) Wood fences shall not connect to the structure. L) Any outbuildings or additional structures shall adhere to the same standards as structures. M) Fuel tanks shall be installed underground with an approved container. N) Propane tanks shall be installed according to NFPA 48 standards and on a contour away from the structure with standard defensible space vegetation mitigation around any above- ground tank. Any wood enclosure around the tank shall be constructed with materials approved for 2 hour fire -resistive construction on the exterior side of the walls. O) Each structure shall have a minimum of one 10 pound approved ABC fire extinguisher placed in a visible and accessible location. P) Addresses shall be clearly marked with 2 inch non-combustible letters and shall be visible and installed on a non-combustible post. Q) Utility lines shall be buried. Only one dog is permitted on the property, and the dog shall be kenneled. The kennel shall be constructed prior to issuance of a Certificate of Occupancy. 9. All trash/garbage shall be kept in approved bear proof garbage containers. 10. Site specific soils engineering studies and proper soils engineering techniques shall be utilized to insure correct foundation design. 11. No development, including grading and vegetation removal or disturbance, shall occur outside of the approved building envelope, except for utility and driveway extension and maintenance, and as may be necessary to implement the wildfire mitigation measures required elsewhere in this document. 12. An access permit is required prior to issuance of a building permit. 13. All material representations made by the applicants in the application or in public meetings shall be adhered to and considered conditions of approval, unless amended by other conditions. Lance Clarke, Hearing Officer LO Date Exhibits A. Application & Site Plan B. Referral comments C. Public comment Appli ant or Rep entative 'T A5 A Dat 1 _ I LOT E-11 O. eswC. ./- 111111111111 Will IN , - 1111111111111111111111 Hill IN 1111111111111111 HE 1111 2 ,q26393 A 0.@@ 1D90.00 NZ@.005PITKINUTI DAVIS COUNTYCO Lot E-10 � &. � 7 ƒ I I- (o(ro(o8 3 bis Or, l A Z uQP cr Vvt I I 6AMfi-m in ba tnv V T cw 0 Q0 c iE SEE INSPECTION PORT CAP COVER DETAILS. Separation Fabric: Mirafi 60OX or 140N, NO OTHER MATERIAL From to be used. Distribution Manifold (typ.) Il Gravel Depth: 7.5' (min.) See Notes, Sheet 1 Depth Variable - Minimum COVER: 1.0 -ft. FINISHED GROUND 4 -inch Sewer Pipe meeting ASTM D3034 specifications, set plumb and straight over end of distribution pipes as shown onSite Plans. Distribution Pipes MUST be visible from surface on ALL inspection ports. 14 -inch Sch. 40 P.V.C. Distribution Pipe - WITH CAP. Caps shall be glued to ALL ENDS of Distribution Piping. See Distribution Piping End Details. 12 -in. DEPTH OF J -in. WASHED GRAVEL 0 0 0 = 2.00' (Hz. O EXTENT OF FIELD BEYOND END OF DIST. 0 0 0 PIPES) Provide EIGHT (8) 4 -inch Diameter Native Earth at bottom of J holes in the bottom Absorption Field. 7.5 -feet of each Inspection Port, spaced roughly Extend 4 -inch Inspection Port Pipe to 6 -inches on center. bottom of screened rock absorption field. Do not cap end of 4 -inch pipe. INSPECTION PORT & FIELD DETAILS Not to Scale Existir Gravity Sew, from Resident External Splice Box. For SmartFilter Alarm. Plan View-Existinj4 1,000-2al. Concrete Septic Tank Dimensions and Volume to be Field Verified by Engineer and Pitkin County Not to Scale i-------------------------------------- A -------------------- Depth of 24" Dia.Adjust Risers so Cover over lids Risers that depth is, no greater UNKNOWN than 4 -inches. NOTE: The Distribution Manifold — MUST be set level across its entire length, on a 6 -in. thick bed of Existing consolidated Pea Gravel. 2 -ft. Gravity Sewe (typ) from Resider e 3" 14" 10" (-1 (min.) (min.) (min.) Vertical Pipe Riser from Pump Vault Install: ONE (1) ELBOW EACH SIDE l,' -in. Sch. 40 PVC Discharge Manifold li-in. 90' ELBOW (typ ) PLAN VIEW - DISTRIBUTION MANIFOLD DETAILS Not to Scale 2.00' (tyP ) li-in. Distribution Pipe. Perforations start over absorption field. Vertical Pipe Riser from Pump Vault Install: ONE (1) ELBOW EACH SIDE Extend to 5 -ft. (min.) Below Finished Ground LDistribution Manifold: MUST be set level on 6 -in. thick bed of consolidated Pea Gravel. SECTION VIEW - DISTRIBUTION MANIFOLD DETAILS Not to Scale Setback from Residence Varies: 20.00' (min.) Site for Absorption Field MUST be staked in the field by a PLS. Existing Driveway -------------------------------------------- Separation Fabric to be installed on all side walls around the perimeter, as well as the top surface of the Absorption Field. Fabric shall be Mirafi 60OX or 140N, no substitutions. `\ Notes: 1) Proposed gravel depth has been set at 7.5 -foot, based on the worst (slowest) percolation rate taken on September 2, 2008. Only two percolation tests were completed (see Percolation Test Results, Sheet 1), due to on ultra -fast draining test hole. 2) Final gravel depth will be dependent on the results of two (2) additional percolation tests performed at the locations shown on Sheet 1 of these plans. 3) In the event that areas of very high (fast) percolation tests are found, then an additional four feet (4 -ft.) of excavation will be required, and a 4 -foot depth of concrete sand will be placed over the bottom of the entire field. Depth Varies: 5.50' (min.) er suit nt Filter with to -in. and SmartFilter i optional. Extend handle to within T�i 3 -in. of inside of lid. MINIMUM SLOPE: 2% IIII \7 IIII Gravity Sewer IIII to Pump Vault 3.6'f Poly -Lok Effluent Filter Model PL -122, with �-in. filter openings, and SmartFilter Alarm. - Alarm optional. Profile View -Existing 1,000 -gal. Concrete Septic Tank - Dimensions and Volume to be Field Verified by Engineer and Pitkin County Not to Scale GLUE MAGNET ON INSIDE OF IRRIGATION BOX LID - T^ ALLOW MAGNETIC LOCATIO SLIP-ON LID NOT GLUE 6" ROCK BARRIER at Edge of Driveway rIPCULAR IRRIGATION -STYLE VALVE X & COVER - LID COLOR PURPLE GREEN - LABEL "SEWER" FINISHED GROUND (min.) 4 -in. Sch. 40 P.V.C. COMPACTED inspection ROAD BASE pipe - extend to bottom of gravel bed, perforate as shown in details this sheet. INSPECTION PORT LID DETAILS -III-III III -III i I I Not to Scale Finished Ground - Raise Surface 6 -in. (min.) above surrounding ground, and provide positive drainage away from field. ,-Perforated Distribution Piping ,ils I-II Washed R Screened <— Width Varies - Site MUST be Staked in the field by P.L.S. SECTION THROUGH ABSORPTION FIELD Separation to Property Line (min.) Existing Ground ---------------- 1.0 COVER (min.) 1.00' a Washed Rock 7.5' 14Screened Rock (min.) 141 -in. Effluent Force Main FROST -FREE CAST IRON use Sch. 40 -PVC OR SDR -9 FRAME AND COVER HDPE. Attach 12 -WAG, "UF" insulated trace wire. Effluent Discharge to '11�1 MINIMUM SLOPE: 2% Distribution Manifold and Absorption field. o GRAVITY SEWER Orenco Systems FROM SECOND OSI Sewage Effluent Pump: PSE -5011 (�� COMPARTMENT OF 32 gpm, z Hp, 110VAC, 60Hz �( SEPTIC TANK. Float Assembly: MF3A-Y,B,R-51FS-10 I Control Panel: MVP -S -1 -IR -HT -SA ^(3)^' v bt Plan View - Proposed Effluent Pump Vault Not to Scale FROST -FREE CAST IRON FRAME AND COVER -------------"t-- ---------------------- W GRAVITY SEWER 2.0' (min.) FROM SECOND COVER COMPARTMENT OF '•V SEPTIC TANK. [^�y PRE -CAST REINFORCED CONCRETE MANHOLE' MINIMUM SLOPE: 27 BARREL ~ 121 -in. Effluent Force Main S use Sch. 40 -PVC OR SDR -9 NOTE: 5.0' (mi .) HDPE. Attach 12 -WAG, "UF" O -t pipe should extend from within COVER insulated trace wire. inside of access lid, to the floor mp Vault. Float levels for Pump Effluent Discharge to Off and Alarm conditions will be field. Design pumping volume is Distribution Manifold and 9 P P g Absorption field. `•1 [ fly 300 -gallons. Minimum height .imp Off) level must be 5 -inches p Intake. Pump shall be set off floor of the Pump Vault at least O 6 -inches. MANHOLE JOINTS TO BE SEALED WITH "Rub'R-Nek" MANUFACTURED BY K.T. SNYDER HJ COMPANY OR APPROVED EQUAL. RUBBER ry 0 -RING GASKETS MAY BE USED IF APPROVED BY THE ENGINEER. O Orenco Systems 48" (min.) Sewage Effluent Pump: PSE -5011 (NO JOINTS) BOTTOM SECTION OF MANHOLE/PUMP 32 gpm, }-Hp, 11OVAC, 6OHz CHAMBER SHALL HAVE NO JOINTS Assembly: M VP- -1 R-51FS-10 TO A HEIGHT OF 4 -ft. (min.) trol Panel: M-Y,B,R--HT-SA 48" (min.) 71 17, nJ i 0.50' Pump Bottom COMPACTED SCREENED ROCK BEDDING, OVER COMPACTED NATIVE SOILS. Profile View - Proposed Effluent Pump Vault Not to Scale NOTES ON DISTRIBUTION PIPING: 1) Use smallest size Hole Saw to drill hole in 4 -inch Diameter Inspection Port Pipe, to allow passage of 141 -inch Sch. 40 P.V.C. END CAP. 2) Drill :&-inch holes at the 5 o'clock and 7 o'clock positions, alternating positions, on 4 -foot centers along length of each Perforated Distribution Pipe. 3) Begin 33 -in. holes 2 -ft. INSIDE edge of the Adsorption Field Boundary. 4) Each Perforated Distribution Pipe is to start at the Distribution Manifold, and extend to within 2 -feet of the end of the Absorption Bed. 5) Distribution Pipes are to be set starting 4 -feet in from the Eastern Edge of the absorption field, and on 4 -foot centers thereafter. TWO (2) Perforated Distribution Pipes are required. Each perforated Distribution Pipe is to be variable in length, see Sheet #I- 6) DO NOT bury any portion of the Perforated Distribution Piping until inspected and approved by the Engineer. 14' -inch Sch. 40 P.V.C. Inspection Ports - present at the Distribution Pipe - WITH END ends of ALL Perforated Distribution Pipes. 14 -inch Dia.. Perforated Separation Fabric: Mirafi 60OX Distribution Pipes to or set or 140N, NO OTHER MATERIAL to LEVEL to within t 0.05 -feet. be used. From Distribution Manifold (typ.) Perforated / • • Pipes to be centered • - drilled C 6 o'clock 12 -inch thick bed of 34 -inch WASHED GRAVEL. position in End Cap. PERFORATED DISTRIBUTION PIPING 1 DETAILS Not to Scale C4 O Z w w 2 N • um IX N so O0 Z0Uo .. i' d; u ,> Z N� W1Z IL _ O v WN Wo U� (3)}y0 Z ZO m 50 Z m0.0 N J W N Utn t1J Qt7 Q n t M Fa (� N 0 ►/��� W% ^�1 m ►v/a� NO 1 4Z �a •H �W t� 0 O W F ui m NN ^j �y N 140 Ol t nz �U al' m W F �W O N �W ¢ .n V ¢ a c m Z m C V ILA O H � o 0 � N Qi m Q N 3 � fir mom w o W Q O M � � m r0 � 0 ? o 4 r U 0 0 QUJ ~ Z> j W ce AZ - J Certo Cw • T zj�•rn,�n„p. 6 f L co rL m Q a Y } m V V w Q m 0 y m Z O an V) w v d � a 0 N W o Q p 0 w O ceZ 1 \\ 10 0 10 20 301 \\\` LEGEND I o `\ • FOUND REBAR - NO CAP? GRAPHIC SCALE IN FEET I SFrsve ``\ ° REBAR SET, OR FOUND WITH CAP MARKED L.S. 14111 1 INCH = 10 FEET a ` ® EXISTING WELL I- 10.00' ro. ♦ EXISTING POWER POLE I sF __ EXISTING EDGE OF GRAVEL ROAD OR DRIVEWAY 9C� I \ ♦ C2` - oHE oHE EHE - Y \ EXISTING OVERHEAD UTILITY LINE I ro-`\ wsvc--wsvc EXISTING WATER SERVICE LINE h SFT \ �10f, `♦ EXISTING 4 -in. SEWER SERVICE LINE (SDR -35 or Sch. 40) EXISTING SEWER CLEANOUT ro" ` s \ i.a5^i.es' PROPOSED 1 1/4 -in. Sch. 40 P.V.C. PRESSURE SEWER LINE (SOLID) F \ I rg9C ` s W \ \ASy as asPa PROPOSED 1 1/4 -in. Sch. 40 P.V.C. PERFORATED DISTRIBUTION LINE UTILITY EASEMENT♦ 8. / `\O�kt, PROPOSED INSPECTION PORT P -v- PROPOSED PUMP VAULT P72 \ \ Oa2 PERCOLATION TEST HOLE (NUMBER 0 TOP RATE @ SIDE) � PROFILE HOLE LOCATION s \ 99 PTB PROPOSED NEW PERCOLATION TEST HOLES / Existing Potable Water Well �\ ♦\ Permit No. 214537 \ Reception No. 0438098 \ / \ Property Line FLOODPLAIN NOTE: This property is adjacent to Big Kline Creek. The FEMA Flood \ Insurance Rate Map for this area (08097C162 C of June 4, 1987) shows that this ` property is outside of the 100 -year floodplain for the Crystal River. No floodplain \, ` / yt\ •ty/ � mapping has been done on the Big Kline Creek. The area occupied by the residence and SFr \ N/ / the absorption field is at least 40 -feet vertically above the Big Kline Creek. It is extremely doubtful that the 100 -year flood will impact the property. \ \ C/ 4c Y \ Cv N/ s r\ \ m sF � ♦ � r \ C y bqC W ♦ Water Service Line -approximate location. LOT E-11 ro \ \ N 'r t 0.45 AC.+/ \`\ 3� rJ o / / Existing �\ y Shed J, n P6 \ \ 20' SETBACK �(` I I om 0m 0 L r/te" sdF L/ Z C1 NOTE: Steep slope northeast s f Shed and W o / / ' / \\ / \ N 1O sFr 20-11. Building offset o cry0' 9 / to Absorption Field / 0222 Bobcat Lane - / \ 1 Existing 2 -story frame house - 3 Bedrooms o1 o / Proposed NOTE: Steep slope northeast � O \ Deck with Relocated z c �of Shed and House. / / ; Room Above w Shed > / �/� 8Pc Aye / ♦rte IK �/ ✓ oma, E`, SEiBPGD N y,, SUB Y� / wELL , \ n SETH2C ELL S TB f �- -i v0.�" `\ •! aA / % J � � S. L .�� it m a� e\ Existing c/ \ �s Shed 9 Existing 1,000 gal sot �0>. s �O //a1\ Cis 4S Concrete Septic Tank �i�' O O m �Lc� wsv wsvc (to remain in place) �a /'' - p� O- \ e�r�s i / PTB Y' �s .az ee 3s Q �5 Existing Fence. \ \ ee ,4SA S e ee /ee ore e P,T22 ae ee N s_. C) h Proposed New Pump Chamber \ -o See Details, Sheet 2. o \\ m o 0,:p 0 0 n i �S SS ^ ' ee PT�/ / / / / / Rock Barrier between/ % driveway & absorption field. `� Bent rebar J11i L.S. 14111 / Perforated Distribufion Piping ' See Details, Sheet 2. / Absorplon Field Boundary Area Available: 652-sq.ft. Minimum Required Area: 1,225-sq.ft. Use Deep Gravel Formula to achieve required area. NOTES,- / 1) Existing Septic Tank is believed to be a Copeland 1,000 -gallon concrete tank, with a single baffle wall. 2) Actual physical measurements, or inspection of the cast -in tank label must be made to verify the tank size, excavate and expose as required. 3) An effluent filter must be installed. A Polyl-ok PL -122 residential filter, available from the manufacturer shall be installed. 4) An effluent filter alarm is strongly recommended, product is available directly from Polyi-ok. 5) The existing absorption system(s) are believed to be: a) An Infiltrator BED system, with 30 -units, most apparently crushed by being driven over, Pitkin County Permit #98006. b) A gravel bed of some description, placed where the Infiltrators had failed, details and extent unclear. 6) The existing Infiltrator chambers must be removed in their entirety, and disposed of in accordance with Pitkin County regulations. 7) The extent of the existing gravel field is unknown. It may be left in place if: a) Its extent can be determined to not impact any setback requirements for the house, the property line, or the well. b) It does not show signs of failure. AND c) Pitkin County Environmental Health approves its remaining in place. 8) The existing gravel field shall not be counted toward the area required for the new absorption field. 9) Extend the existing profile hole to a depth of at least 15 -ft., due to greater gravel depth. Take soil sample at depth of 15 -ft for gradation and hydrographic analysis. Pitkin County Health Department Onsite Wastewater Treatment System Pressure -Dosed Pipe with Deep Gravel - Revised October 3, 200_8_ Individual Sewage is osal/Treatment S stem T e: Se` tic Tank' Parcel No. 2729-293-04-01 1 Enc Petterson 0222 Bobcat Lane' Project; Owner's Name and Address Redstone, CO Number:; 08706 House Size (sq ft.):1 1,0P01 75 gallons/person/day Number of Bedrooms in Main House Number of Offices, Libraries, Studies, Similar -sized Rooms in Main House Number of Bedrooms in Detached Caretaker unit Number of Offices, Studies, Similar -sized Rooms in Caretaker Unit (If the caretaker unit is ATTACHED, treat as if part of main house.) Total Bedrooms and Potential Bedrooms:' U U Average Daily Waste"Flow : 450 gallons/day State Review Required?: No Average Percolation Rate (t) =F 42.0 minutes/inch Design Flow (Q) - Average Daily Waste Flow X 1.5 Design Flow, Q = 675 gallons/day Absorption Area = A - 1.4(_40 1224.86 sq. ft. of absorption area rec 3 persons using additional bathrooms. /N) num of 2 bedroom . I Percolation rate is WORST (slowest) encountered in tests by TJK on 09/02/08 - >5-mpi, 42-mpi, 4-mpi. ELGIN EN -DRAIN I I 8.8scift-. Tank Size for Pitkin )County and kSepbc Tank is Garbage Increase tank size with Disposal in S Garbage Disposal! (25%) use. Minimum Tank Capacity = 1,055 gallons (750 gallon absolute minimum) Suggested Practical Tank(s) 1250 In -Place -tank is 1,000 gal. concrete. size:' form of a pump tank. 1,225.00 an in DEEP GRAVEL AREA REDUCTION 1) Formula: Lr = [(Li(W+2)]/[W + 1 +2d] Where: Lr = reduced length (available length); Li = required length; W = Width of Field; d = depth of gravel below pipes. 2) Required minimum area: A(min.) = 1,225-sq.ft. Available area is 652-sq.ft, in a roughly rectangular area. Rectangular field with area of 650-sq.1t., approximately the some dimensions as the actual field is 13 -ft. by 50 -ft. (650-sq.ft.) 4) Therefore, minimum length (at W = 13 -ft.) PERCOLATION TEST RESULTS FORM = 95 -ft. (value rounded up) 5) Place values into formula, solve for depth: 50' _ [95'(13' + 2')]/[13' + 1' + HOLE No. DEPTH OF TEST HOLE - below existing ground TIME TME TME INTERVAL INTERVAL DEPTH To WATER I.EVII. (FROM Tor OFSTAKEI DROP in WATERLEVEL PERCOLATION RATE IL �'IL ($.) (military) (min) on inches (inches) (ma✓in) #1 4'00 14:00:00 "J WW Hole did not hold water - running hose would not fill hole more than 0.1-f)ot, which emptied immediately upon hose removal. Hole might be sited over a void, or beside a large rock, or a gravel lease. Area to he re -tested when final absorption field has Q1% M0 Ea o U o �W W a' (7 c ed N' m NZ m aZ �NOO �a 'ry 17:15:00 0 Hole Percolation Rate: Q Z in to r . #2 IIG N0 Q0 15-40:00 , U IL 0.00 15:4290 002 2.0 1.00 1.00 2.00 15'44'00 092 2.0 2.00 1.00 2.00 o 3.00 15:4800 094 4.0 3.00 1.00 4.00 1630:00 042 42.0 4.00 1.00 42.00 170300 033 1 33.0 5.00 1.00 33.00 � o Hole Percolation Rate: 42.00 V (!f o #3 16:4490 N M O 0.00 _ d 16:4600 002 2.0 1-00 1-00 2.00 16:48:00 002 2.0 2.00 1.00 2.00 1650:00 002 2.0 3.00 1.00 2.00 165200 092 2.0 4-00 1.00 2.00 165490 002 2.0 5.00 1 1.00 2.00 163800 004 4.0 6.00 1 1.00 4.00 17:0000 092 1 2.0 6.50 1 0.50 4.00 mom Vi U O E 8 Hole Percolation Rate: 4.00 M O N i N � Notes: Percolation Tests #1, #2, & #3 were performed on Sepetmber 2nd, 2008. The "Hole Percolation Rate" in this case, is the worst rate recorded during the testing period. DEEP GRAVEL AREA REDUCTION 1) Formula: Lr = [(Li(W+2)]/[W + 1 +2d] Where: Lr = reduced length (available length); Li = required length; W = Width of Field; d = depth of gravel below pipes. 2) Required minimum area: A(min.) = 1,225-sq.ft. Available area is 652-sq.ft, in a roughly rectangular area. Rectangular field with area of 650-sq.1t., approximately the some dimensions as the actual field is 13 -ft. by 50 -ft. (650-sq.ft.) 4) Therefore, minimum length (at W = 13 -ft.) is: Li 1,225-sq.ft./13-ft. = 95 -ft. (value rounded up) 5) Place values into formula, solve for depth: 50' _ [95'(13' + 2')]/[13' + 1' + 2d] 6) 50 - [1,425]/[14 + 2d] 7) 50[14+2d] = 1,425 8) 700 + 100d = 1,425 9) 100d = 1,425 - 700 10) 100d = 725 11) d - 7.25 -ft. Use 7.5 -ft. for construction purposes. O w w S • U� N stD Z0 Ua .. W 6U �> z_ IL �'IL 0 i�� N W in LW 1 "'0 Z o 44a Z3 JN "J WW Q1% M0 Ea o U o �W W a' (7 c ed N' m NZ m aZ �NOO �a 'ry W 0 14 0WW Q Z in to r . IIG N0 Q0 I - U IL P,Z (n a� M W f - a 4" z g UP o N a m ^' o m Z m � o 0 V (!f o O a N M O _ d o y d N F O mom Vi U O E 8 M O N i N � L 2 a O O Z u w t - w o 0 ,1 a o r Qm s $ � T m U V n W m < 0 -e m z O cn v, w •` 42 0 r w e �p e w O