HomeMy WebLinkAboutpitkin.eh.273503300012 (1988)2
Mob-
73-5 D33--D6-DIZ
-'� ASPEN*PITKINr
ENVIRONMENTAL HEALTH DEPARTMENT 7� 00kY,fir
INDIVIDUAL SEWAGE DISPOSAL PERMIT NO.
.YPE OF PERMIT:
( )Initial Construction ( )Emergency Use ( )Repair Work,(Piovious Permit 1
or installation
( )Use Permit as a result of Sale ( )Other:
ISSUED TO:
OL,rner__,L
Mailing
Address
Agent -U.
Mailing
Address
DATE
.) ( )Alteration of an existing system,
(Pr/eviousPer. it i
OF ISSUE C� 3 U�
Phone 92 '�3jj
Sewage Disposal System Work to be performed by
This permit {MESvaali/d/�onnly for premises )0 cation by the following legal description:
LO? SIZE �J / , WATER SUPPLY AVERAGE PERCOLATION RATE. I �'� 14
This Individual Sewage Disposal Permit is granted with regard to the following use:. \,%)l} 1 LcL 7 S f � 1
Nuta"V,7 oft Dodicoms _ �- Lofts Garbage Disposals_ Dishwashers �� Clothes Washers .
CALCULATED AVERAGE DAILY WASTE LOAD C��A—L-LLONS.
T F E NATURE OF THE SYSTEM INCLUDED UNDER THIS PERMIT:
Type of Tank or Treatment Unit:/e.�1I/�/�� Tank.Capaccity ��'L'(� _Callon Hinimu:a
Mrehod of Final Disposals
lt-VC-�/v6-Eie�p c16soleloln&- ��� Abeorptiop Area �(�? t Square Feet Minimum
A Description (including brand name, if any/) of other equipment or appurtnances:
Other C ndit ons or Specificationet PLANS 'A�� sP�G F/�!A-RCAPS' QF -
3 C) TO B� f=oLLr� CcJE O�-,-VAF
T//S. Rl;ga/?FD -r,') -GAAAD 4 i7/CC 7?11 I �'��I eF 7)1 S Fej6b J1W f ! PF.
STAGES REQUIRING INSPECTION BY THE HEALTH•DEPARTMENT: '
( )Ac -fore Excavation (/Upon completion of excavation and prior to placement of gravel�iBefore covering distribution
�Prior
' 1 ystem of absorptionfield
to backfill of any component ( IOther, Specify:Plans and specifications of the proposed sewage disposal system have been reviewed and are considered satisfactory. Permission
is harct;y granted to thf, owner or his agent to perform the work indicated above in accordance with the Pitkin County Indivi ual
Scwa;e Disposal Regulations in effect on the date of issue. In addition to general provisions set forth on the reverse hereei,
this Permit is subject to tl,c following additional terms and conditions:
APPROVED FOR ISSUE: BY (title)Ti/
The above in.iividual ecrra•)o disposal system installed by
I his tx•cn in:ipectcd fur use by a representative of the As(:cn I':t 1n Lnvironmcntal Health nepartinent. The owner as:i&.—os arl
renpeonsibiltty in cane_ of failure or inadequacy of this ewage ispoaal system. Complete as -built drawing attached.
DATE O1' F 'AL RLPET N 07
- _
TITLE x4vix %7�AG�f7 4�`G/ �
130 South Galena Aspen, Colorado 81611 303/925-2020
ASPEN40PITKIN
ENVIRONMENTAL HEALTH DEPARTMENT
APPLICAZION FOR AN INDIVIDUAL SEWAGE DISPOSAL•PERMIT
Name of OWNER /'N �� PHONE _
Address of OWNER
Name of APPLIC.ANT " L"Ikj5�
PERMIT TO BE: (vSPicked Up
'V -o. 20%2-
Mailed
01zMailed to:
( )Owner ( )Applicant
�-for j2. A -G.
p�Shep,� S 16�
TYPE OF PERMIT: ( )New Installation ( )Repair
( )Emergency use ( )Alteration NOT due to failure
PHONE a?,�- 4364
LOCATION OF PROPOSED SYSTEM:
Legal Description
Lot Block Filing Subdivision Size of Lot acres
TYPE'OF STRUCTURE: (4 Single Family Dwelling ( )Other: Do you plan any further additions to the
residence? ( )YES NO
No. of bedrooms / NO. of Lofts ` No. of Garbage Disposals �_ No. of Automatic Dishwashers
No. of Automatic Clothes Washers
'
WATER SUPPLY: ( )Private Well, Depth A¢V or ( )Public, Name of System -
( )Spring
( )Stream or Creek
TYPES OF T.NDIVIDUAL SEWAC:E DISPOSAL SYSTEM PROPOSED:
(.h Septic Tank/Absorption Field ( )Aeration Plant/Absorption Field ( )Composting Toilet ( )Incineration Toilet ( )Mound
( )Recycling, potable use ( )Recycling, other use t )Vault Privy ( )Other:
The initial site inspection must be arranged with the Aspen/Pitkin Environmental Health Department (925-2020. 8:30-9:30 a.m.)
before a permit can be issued. The individual sewage disposal permit must be issued before a building permit can be obtained.
FINAL INSPECTION APPROVAL.MUST BE GIVEN BY THE ASPEN/PITKIN ENVIRONMENTAL HEALTH DEPARTMENT PRIOR TO BACKFILLING ANY PORTION
OF THE SYSTEM.
Application for an indivAuasewLge disposalermit is hereby submitted. The andgraigned acknowledges that the above information
is true and that false illiinval ate the�a�p/li�cation and any subsequent p r it. (�
Signature of Applicant ►":"�• DATE \ �-1��
(This application becomes. invalid 12 month4 from the above date.)
NOTE: PLOT PLAN must be filed with this application.
Please locate the following items by measured distances:
1. Property 'Lines and dimensions.
2. Proposed and existing water wells on subject property and
adjacent property.
3. Domestic water service lines.
4. Proposed and existing buildings, driveways, and other
structures.
S. Streams, .Lakes, ponds, irrigation ditches, and other water
courses.
6. Proposed and existing individual sewage systems on subject
property.
SUBMIT A REVISED PLOT PLAN PRIOR TO CONSTRUCTION IF INSTALLATION IS TO
BE CHANGED FROM ORIGINAL PLAN.
The undersigned hereby acknowledges receipt of this individual sewage disposal permit application and a permit fee in the amount
of S i)0 Receipt Number , Date Fee Received _ `/ // Sr -by ji."l/%
—�-�— Administrative Officer
130 South Galena Street ' Aspen, Colorado 81611 303/925-2020
E S E C Ci?4P
O Irl M EY E R, i N C.
1 +�iR,A Q A4'Et�Utm, !TE 2 1 �3LENV1ft]®D Nt3�3, CO ®ISO I
(303) 9455-1004
TO
�� �► irfi�Iv
DATE�'�
DATE
W
In
L
BY _
Item o NN73 The Drawing Board, Dallas, Texas
, Wheeler Group, Inc., 1982
DATE AND FILE
TO
SC:HMUESER GORDON MEYER, INC.
1 E:? ? 14gm�4D AVE -NUE', SUITE 212 s GLENWOOD S=RIRVQS, CO ®16!]1
(3031 94S-1004
7
J
DATE
DATE
BY
.._. _. _ ._ SIGNED
Item n NN73 The Drawing Board, Dallas, Texas 75286042
0 Wheeler Group, Inc., 1982
DETACH AND FILE FOR FOLLOW
CIRCLE FOLLOW-UP DATE AND FILE
MO H J F M A M J J A S O N D
X
/-�v�� -/tel/ .t3%�Z��l _/a�q/�
MEMORANDUM
TO: Aspen/Pitkin County Regional Building Departmentn
. r
FROM: Bob Nelson, Department of Environmental Health
DATE: September 20, 1988
RE: Alan Marcus Residence, Lot #4, "Aspen Oaks" Subdivision
This department has been requested by the contractor, Red
Mountain Construction, to summarize the progress on the sewage
disposal system permit for the proposed residence. we have
visited the lot several times and inspected the percolation test
and soil profile holes. The conditions are such on this property
that conventional on-site waste water system will not work. The
percolation test has been done, and the results were acceptable.
However, bedrock was located at 50 inches below the surface on
the portion of the lot checked, and with this limiting
condition, this department cannot issue a sewage disposal permit.
As a result, the contractor has decided to hire a registered
professional engineer to do a design based on the information now
available. The consulting engineering firm should finish plans
next week. While the specific septic system requirements have
not yet been determined, it is possible to engineer a system
which conforms to the County code.
In the meantime, due to the late starting date, the observed
site conditions on this lot, and the expected engineered design,
this department has no objection to your issuing a building
permit to expedite the construction schedule.
cc: Dan Levinson
ASPEN06PITKIN
ENVIRONME.vTAL HEALTH DEQ-ARTMENT
FIELD TEST DATA SHEET
Legal decription: ,jZ ( 1V ,--
Name of Owner:_
Address:
(# & St. / P.O.
Name of Agent:
ax 4:=�
(city)
(state) (zip)
Water Supply: Public Utility__ Subdivision Private Well
Lot Area:: '; '"5 Distance to Nearest Surface Water ft.
Dates Observations Made: Soil Borings: q11', (I by
Percolation Tes s: by
SOIL BORING TESTS
ARAI INA 9 N g I g �nl 3�
TEST
MUM[[A
D[PTN TO [ROVND W ATEA, 'ELT
TOTAL D[/TM
/[[T CHARACTER 01 BOIL WITH TNTC
OBSERVED [STIMAT[O NIGH
\r
�
RM [[• IM I[[T
•Z I_
B-1
"OWNS
I WATER
TEST TIME
DAO► IN VIATEN LEVEL. INCHES
go
6�4� %
NK.T TO
LAST
TEST
DE►T.
CHARACTEA 01 SOIL SINCE Ot4i
IN HOLE
INTERVAL
egYA g
PERCOLATION TESTS
Average Rate:^ minutes/inch
Plan of he ite on the back
Date Signature
BOB NELSON
ASPEN/PITKIN
SANITARIAN
130 S. GALENA
CO 81611
"OWNS
I WATER
TEST TIME
DAO► IN VIATEN LEVEL. INCHES
MIM UT[f
SECOND TO
NK.T TO
LAST
TEST
DE►T.
CHARACTEA 01 SOIL SINCE Ot4i
IN HOLE
INTERVAL
TO ALL
H VM BER
INCHES
THICKNESS IN INCHES I ST WET
OVERNIGHT
N MINUTES
LAST PERIOD
LAST PERIOD
P[RIOO
ONE INW
/Ut
sib
3 g
P-1
P-2
'
S�
'
20
P-3
�/
c� (
r
if)
• ,
l '7
3 / �v
C
J7
If
Average Rate:^ minutes/inch
Plan of he ite on the back
Date Signature
BOB NELSON
ASPEN/PITKIN
SANITARIAN
130 S. GALENA
CO 81611
"P M
V
S(CHMUESER GORDON MEYED INC.
1512 Grand Avenue Suite 2
GLENWOOD SPRINGS, COLORADO 81601
(303) 945-1004
TO Er/ f DA jl�pj \( . di
WE ARE SENDING YOU lAttached ❑ Under separate cover via
Vk
❑ Shop drawings ❑ Prints [I Pla
❑ Copy of letter, ❑ Change order bL:
DATE
JOB NO.
ATTENTION
RE:
❑ Samples
COPIES DAT iNO. DESCRIPTION
THESE ARE TRANSMITTED as checked below:
For approval ❑ Approved as submitted
For your use ❑ Approved as noted
As requested ❑ Returned for corrections
r review and comment ❑
❑ FOR BIDS DUE 19
REMARKS
COPY
the following items:
❑ Specifications
❑ Resubmit copies for approval
❑ Submit copies for distribution
❑ Return corrected prints
❑ PRINTS RETURNED AFTER LOAN TO US
SIGNED -._J
PRODUCT 240-3 � mc., Gldm Mass. 01471. if enclosures are not as noted, kindly notify us at once. ;_� _ _ ,�•D
C
" 'WR 5•Rev. 76 1LORADO DIVISION OF WATE. .ES( .RCES
81b Centennial Bldg., 1313 Sherman St., Denver, Colorado 80203 Mq�2
E-CEIVEG PERMIT APPLICATION FORM `J �3.
Application mus �- �/� �3
be complete where XX) A PERMIT TO USE GROUND 'NATER a� >'y� o0.
applicable. Type or MAR 1 4 i9�3 XX) A PERMIT TO CONSTRUCT A WELL
Print in ° jF46
BLACK FOR: XX) A PERMIT TO INSTALL A PUMP l i L
INK. No overstrikes YIATEE RG&mR= ou.%0
or erasures unless STA71 • EflL MW i. -Z=;;_
initialed.t�14 ( ) REPLACEMENT FOR ,NO.
( ) OTHER
WATER COURT CASE NO. CL-i�p -
(1) L1pp1 Ir'An111•
NAME Alan M -Arcus
STRE:TZ,Q. Box 4.87
CS T'r�3a ;, e Co 8162'
(scare) (ZIP)
TELEPHONE NC7.6?-,1606
(Z) LOCATION OF PROPOSED WELL
County Pij'
'! %: of the %, Section
Twp. _10 �. Rng. 8�_ 4] 6
ft s) I E.'N) P. M
(3) WATER USE AND, WELL DATA
Proposed maximum pumping rate (gprm) _ 1-5
Average annual amount of ground water
to be appropriated (acre-feet): R
Number of acres to be irrigated: 0
Proposed total depth (feet): ?00
Aquifer ground water is to be obtained from:
— M nn_a— s Shale -
Owners well deslgnatlon _
GROUND WATFpI TO BE USED FOR•
( X) HOUSEHOLD USE ONLY - no irrigation (0)
( ) DOMESTIC (1) ( ) INDUSTRIAL (5)
( ) LIVESTOCK (2) ( ) IRRIGATION (6)
( ►COMMERCIAL (4) ( )MUNICIPAL (8)
( ) OTHER (9)
DETAIL THE USE: ON BACK IN (11) _
FOR OFFICE USE ONLY: DO NOT 'WRITE IN THIS C0L'-t%1Pi
I
Receipt Sb 1
i pt No. /
3asin Dist.
NDITlOt`1� r1t= ppoROVAL
This well shall be used in such a Hay as -o cause
no material injury to existing water rights. The
issuance of the permit does not assure the appiicant
that no injury will occur to another vested ',eater
right or preclude another owner of a vested '.eater
right from seeking relief in a civil court action.
1) APP=20VED PURSUANT TO CHS 37-92-802(3)(b)l:
AS TEZ ONLY WELL ON A RESSIDENTIAL SITS OF
ACRES DESCRIBED AS LOT NO. 4, ASPM OAK LO:S
PIMUN COUNTy.
2) TBH USE OF GROUND WATER FROM THIS WELL IS
LIMITED TO ORDINARY HOUSEHOLD PURPOSES I`JS IDi'
SINGLE FAMILY DWELLING
,'AND SHALL NOT BE USO
OUTSIDE THE HOUSE FOR ANY PURPOSE.
3) THE RETURN FLOW FROM THE USE OF THE WELL
MUST BE THROUGH AN INDIVIDUAL WASTEWATER
DISPOSAL SYSTEM OF THE NON_EVAPORATIVE TYPE
WHERE TBH WATER. -IS BET== TO THE SAME STRE,
SYSTEM IN WHICH THE WELL IS LOCATED.
- 7rJ tel• 3-3c ->��
QR1LLER,*S.C,-p*t,
ZL
APPLICATION APPROVED
(4) PERMIT NUMBER i S O b O:)
DATE ISSUED
Name g1e1 tmn T1—_ a 111 ws
EXPI RAT ON DATE ' 31199Q
Street —P. 0 bar 10 59
ate t of A R)
Telephone No. 92 -4talz Lie. No. —095 BY
_ G
(5} THE LOCATION OF THE .. 'POSED WELL and the area on
which the•water will be used must be indicated on the diagram below.
;�Z llse�thee CENTER SECTION 0 section, 640 acres) for the well location.
�w
-� ' — — — _ I
{� 1 MILE. 5280 FEET ---yl
_
i NORTH SECTION LINE
I
NORTH
D ' I
' J H
C I m
I n
X —
j W
1 _ y r
--.: _ _ -
R I �
— I
-SOUTH SECTION
The scale of the`diagram is 2 inches - 1 mile
'•fach iiria)r s4`uare represents 40'acres:' - '
- - -WATER EQl11. L ' TS TABIH (Rounded Figures)
- - AYi a'cre-toci eov+rs t's"bf lindl'tooi demo - 1
I cubit foot per second (efsl 443 yahoos per minute (9pet)
A family of 5 will require apmximst ly t acn foot of water per year.
I acre-foot ... 43.560 cubic feet ... 325,900 gallons.
— 1',000 gpm Dumper! continuously for one deypoduces 4.42 acre-feet.
(6) THE WELL MUST BE LOCATED BELOVti
Y �1:i4a m section lines.
ft. from North sec. I i n e
in ,in or soutn)
1120ft from West
(east or wast) sec. line
LOT 4 BLOCK FILING e
SUBDIVISION Aspen Caks
(7) TRACT ON WHICH WELL WILL BE
LOCATED Owner: Alan warcus
No. of acres S.0 . Will this to
the only well on this tract?—yes
(8) PROPOSED CASING 'PROGRAM
Plain Casing
= in. from 0 ft. to 40 ft.
1
5 in. from 35 _n, to 2-`0
Per, -orated casing
52I in. from 2�0 ft. to '00 4.
in. from ft, to
(9) FOR REPLACEMENT WELLS givedistance
and direction from old well and plans for plugging
it:
(10) LAND ON. WHICH �GHOUND WATER WILL BE US D• - --
Qwner(si •AT ATS I'Sa-Tf Q �.r. « W, sC.. -
V No. of acres• 5.0
Legal description:, rt �1E� 4 As;; r Q e
1e-
(11) DETAILED DESCRIPTION of the use of ground water._ Household use and domestic wells must indi. n type of disposal
System used. Household. Use with State and County approved septic and leach field
(12) OTHER WATER RIGHTS used on this land, including wells. Give Registration and Water Court Case Numbers.
Type or right Used for (purpose) Description of land on which used
'•.L%i.Ls;,e t .` - ;arsal,M+,,ti,<.;��:� �__.._..._.......�:..__�_.......,_._......_._. _ w� -' -
(13) THE
.TRU
-� Z�
VONArU,99 OF
AT THE INFORMATION SET FORTH HEREON IS
PLEDGE.
`5,,�, �.w`'+^as..,.....:• _._..... .. _.: •.lam+..... -�=:'. L._: +..__.
_ ...r
•' .w✓ .,R� .. a .. . ".i�.... _..- -
•_,»�••►r, 'Usw additron sheets of D required.,
- .ra•*��. „ • • paper it more space is r ui __ .....,. - ..
vCXJNf7 KEP5Nz, N�)UP
SCALE. I" = IOO'
7N'/4 CCaZNEfZ
T
(s c lo)
N N
D 10 20 40 (00 50 I00 FEk"-T
�jCALE I " = 20'
PAS l-) 01 f3E ° KIf Cfi FC�JNO I�IONUME}�rS A5 ZHOWN
DATUM FLAthIE AS�UMF-JD EL-E-VATION 100.0 AT r5EI,CH
MARK ir1CWN
5URYE.YOK5 CEKTIFICATE
I, DA-JIEL P. M`KENZIE, CtKTIF`( 'THAT TN(-) hAAF
NCCUIZATELK )E-PICT`S A 5URVE`I PEKF0ICME-D UNnE,, M`i
�Ut'1=RVISIcN <7N AFFIL 1 t 41 llbfP, OF A FAKCEL OF LAND
AS SHOWN 1 -[ERF -b CAL -h0 KN6WN �i "-0T 4, ;ASPEN OAY-
LOTS° FLAT or 5A11J "^SPEN OAK LOTS" NEVER KECORTDED).
Ad
ALPINE SUIZ�/E`fS, 1 f1 DANIEL F M`KENZIE
A�KZIL 5, `i?�Y L 62 20151
ti r,CE A
lC G„TTC -,pi mnl, It 1 , j,,I,G I , 1
1n,.� ,,, 1..',1 w
Alpine Surveys; Inc.
Post Office Box 1730
Aspen, Colorado 81612
303 925 2688
FC1JNi7 - KEO,&F, W1 PLA CAP
L. h. 20i5I --
7o\\ °LOT 4
10
\\ \\ \\ \ \\\\\
` \ \\\ \� \ \ \ \ \ \\ \� 70
\
\ \ \ \ \
C
/ xRufs> OAK:go
\ \ \ \ \ \
vvv
\ yET SPIKE
T-
Surveyed 4 1 f7f5 5J -JI Hevisions
Drafted 4 5 8b r-�) K,
IIUG , , , ,, r,, , , , v
"LOT 4 "
ASPEN OAK- LOTS"
?ITKIN C_OUNT,�[, GOLOKflr�D
1,4 . i'-
�,.�..�,, ctia _.0
Client V M,&rzCU`D
NOTE:
PROVIDE SN
DRA/NAGE L
3'
/.5.1- 1 8'
8'
SAND AS REO D _
SEE TRENCH DETAIL
sic'Yk 400
Ka
r 07:�
OF CC
43'
&A
B IAPPRp—
J
SECTION A -A
SCALE.• -,'y " = /'-0'"
M/RAFI 400-N
FILTER FABRIC
NATIVE BACKFKL WITH
6" Of TOPSO/L
6-
(T YP)
"'(TYP.))
�a — 1
REMOVE TOPSOIL
MIL. PVC LINER
EOD ALL AROUND
)N TRENCH
21
/.5'
0
� SUGGESTED TOPSOIL
FIL L LINE
—SEE TRENCH DETAIL
u17.5'Oe •-�
4 "PVC CL 160 PERFORATED
PIPE SLOPE O"/FT.
a " TO 21 '"
SCREENED ROCK
CA' L E 4
DEPTH AS REQUIRED TO PROVIDE MIN. 4' FROM
BEDROCK TO BOT TOM OF
AFTER TOPSOIL IS REMO/ED (TYP.)
ABSORPTION TRENCH
DETAIL
SCALE: J"= l'-0"
DESIGN CRITERIA
1. Number of bedrooms = 3
2. Assume 2 persons/bedroom and 75 gpcd
3. Flow = 450 gpd (average daily)
4. Perc = 40 min/inch
5. Area (bottom of trench)
A = 1.5 0 = 0.055 Q
L
Where: 0 = averaae daily flow
L = loading rate based on 40 MPI
(L = 0.40 qal/sq.ft./day)
A = 1.5 (450) _ 0.055 (450)
0.40
A = 1662.75 sq.ft.
6. Length of trench:
Width = 3'
Length - 1662.75/3.0 = 554.25'
7. Make trench combine for total length equal to 555 feet.
lv .9
F•
1. All materials, installation practices, setback requirements, etc.,
shall comply with the Pitkin County Individual Sewage Disposal
System Regulations.
2. The absorption trenches shall be constructed so that the bottom is
level + 0.1 inches. Place trench in natural ground; no portion of
the trench shall be placed in fill. Provide positive drainage away
from trenches.
3. All areas disturbed by construction shall be reseeded with native
grasses to prevent erosion.
4. The location of the trenches may be adjusted in the field to better
fit the site, provided all setbacks are met.
5. Use risers as needed to bring septic tank access hatch within 6" of
finished grade.
6. Cast iron pipe or pipe of equal strength or other pipe properly
supported to prevent failure by settling shall extend from tank for
a distance of at feast five feet (5') from the inlet and outlet
ends.
7. The Contractor and Owner shall take whatever measures are necessary
to assure that (a) septic tank and sewer lines are completely
water -tight to prevent infiltration of groundwater into the system,
and (b) the system is to be installed to prevent freezing of all
gravity sewer lines.
8. The location of existing utilities must be verified by Contractor
prior to commencing work.
9. The Pitkin County Environmental Health Department and the Engineer
shall be notified when construction commences and kept abreast of
the construction progress so that sufficient inspection can be
performed to assure conformance with these plans.