Loading...
HomeMy WebLinkAboutpitkin.eh.273503400036 (2010)2735-034-00-036 Permit Issued: ®NEW []REPAIR ❑REMODEL/ADDITION [-]TANK ONLY ❑FIELD ONLY ❑AMENDMENT Owner(s): 80 Buttermilk Landowner Property Address: 240 W Buttermilk Lane Legal Description: Size of Lot: 4.2 Size of Building 15000 The system is designed for: unit above the garage. _ Acres Sq. Ft. Detached Accessory Unit: Size of Accessory Unit: DYES ®NO Sq. Ft. An 8 bedroom home, 6 bedrooms in the main home and 2 in the attached accessory Designed By: All Service Septic 1R Phone #: 970-618-5033 Maili Fax #: 303-216-2796 Perc Rate: 15 Minimum Tank Capacity: 3000 Profile Hole(epttf-- 8 #: 1703 Dated: 5/10/10 dress: PO Box 2844 Glenwood Springs dress: TPetz1(o)-comcast.net ( )Depth to Groundwater or Bedrock: Greater than 8' Vi— nn umi AiasorDtion Area: 1301 sq ft w/ 30% reduction PerhAsCb*AtimrM` --I This OWTS Construction Permit is pproved on the ' ition com lian with the engineer design as submitted with the application and the specifications cited above. Changes must be tproved is rtment and th in er prior to construction. This system will consist of a 200 a n single compartment tank followed by a 2000 gallon FAST secondary treatment tank. This will then discharge into a split basin which will equally distribute the effluent to each of the 3 field areas. The splitter basin must be accessible from grade. Each area of the field will consist of 2 trenches connected serially, each with 24 "Quick 4" chambers. The trenches must be separated by at least 6 feet of undisturbed soil. A total of 144 chambers will be used for a total absorption area of 1422 square feet. If changes to the grade of the field area are done, a new design reflecting those changes will be required. This Permit must be kept on-site during installation. The engineer must do a final inspection of the installation and submit an "as -built" letter to this Department within 30 days of the final inspection, unless a longer period of time has been agreed upon, in writing. This Department must also be called for the final inspection with a minimum of 48 hours notice. Minimum horizontal distances between components of the system and physical features shall conform to the requirements of the Pitkin County OWTS Regulation. This Permit is conditioned upon the property owner(s) providing for regular inspection, cleaning, and maintenance of the system by qualified personnel, in accordance with the manufacturer's recommendations and the requirements of the Pitkin County OWTS Regulation. THIS PERMIT IS EXPRESSLY CONDITIONED UPON COMPLIANCE WITH ALL REQUIREMENTS OF THE PITKIN COUNTY OWTS REGULATION, INCLUDING BUT NOT LIMITED TO THOSE CONDITIONS SPECIFIED ABOVE. Plans and specifications for the proposed OWTS have been reviewed and are considered satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated in accordance with the Pitkin County OWTS Regulation. This Permit will expire 1 year from the date of issuance unless construction on the system has commenced. An "as -built" drawing must be submitted and alrovedefore final approval of the system will be issued. i ,�0Expires: �llqi 1 Issued By: '�S�-u� v.. Date: Installer: Reactivation Authorized by: Final Approval Issued By: Date: I New Expiration Date: [-] Feepil ,iNSITE WASTEWATER TREATME.. (SYSTEM (OWTS) CEH/NR �CONSTRUCTION PERMIT APPLICATION _ 0405 Castle Creek Road, Suite 10 • Aspen, CO • 81611 Phone: 970.920.5070 Fax: 970.920.5077 Parcel ID# (available from the Pitkin County Assessor's Office ^� _ 3 970-920.5160 or at www.pitkinassessor.Orgi: V lJ Purpose of Permit: NEW ❑ REPAIR DUE TO FAILURE ❑ REMODEL/ADDITION ❑ TANK ONLY ❑ FIELD ONLY Cost of System Repair or Ret nodel/ ddition (approximate): t/� ope ddress.--, l l � m 1 - 4/� ?/71</-1 0-0 j I 00o .. -a L : Block: Filing: Subdivision: PropeOwner( Email Address: O er's M gDA� dress:' p J� City,fState, Zip: c l Ho P one:Q Business hone: -0•-Lab U *Contact information must be provided for the owner signing this application. Prim ry Contact Person/App cant (if o>owner): gCompanp ✓ 5 5 t b G "04 Cqq ZTplical nt M- g Ad fess: _ \JV City, Stat e: Cell Phone: M 00 - 23 Business Phone: Fax Number Email A4dre -`` / e — Ci e-4• CA Detached Accessory Unit? Size of Accessory U t (square feet): ❑ YES NO p Number of Potential Bedrooms In or Fixture List for the Ac(3ssory Unit: Water Source: ❑ PRIVATE WELL El SURFACE WATER ❑SPRING COMMUNITY/PUBLIC WATER SYSTEM Name of Community/Public Water System (if applicable):Q—N) i ! Engierg Fir � I Job Numb Phone Nu ber: Fax Number: Mailing AddreCity, State, Zip: r,co PLEASE READ BEFORE SIGNING: 1 certify that the above information is complete and accurate and that I have provided complete and accurate information in all of the documents included in my application package. I acknowledge that EH/NR may revoke any permit I am issued if my application is found to contain any inaccurate, false, or misleading information. I understan at no construction may be undertaken on an OWTS until an OWTS Construction Permit is issued. �\ ,- Owner Signature (Requ d): Date: Applicant ign ture Date: 7 FOR OFFICE USE ONL Re ed by EN/H ff: Fee & Receipt #: y p Date: LO Q I �� � .,r� a inns nir n arr nfflra - Ari in Fnrms\OWTS Const forms OWTS construction permit application.As Updated 10/7/08 Pitkin County Environmental Health Department Contact Log Sheet 1►MIM 7 •Y May 10, 2010 PO Box 2844 Glenwood Springs, CO 81602 Ph 970-618-5033 Fax 303-216-2796 Coleman Brothers and Palladium Design PO Box 3287 Basalt, CO 81621 Project No. 1703 Subsurface Investigation and Onsite Wastewater Treatment System Design Proposed 8 -Bedroom Residence 240 West Buttermilk Lane Pitkin County, Colorado Jeffery, ALL SERVICE septic, LLC performed a subsurface investigation and an onsite wastewater treatment system (OWTS) design for the subject residence. The property is located outside of Woody Creek, in an area where OWTS and wells are necessary. SITE CONDITIONS A single-family residence presently exists and is utilizing a separate OWTS, although will be demolished. A barn with an attached CDU is being proposed. The CDU will have approximately 1000 square feet (SF). There is an existing drain field that will be abandoned. The proposed drain field area is relatively flat, and vegetation consists of a moderate cover of grasses. Water is provided by a spring, (also serving the main residence) which is located to the east of the proposed drain field. SUBSURFACE The subsurface was investigated by digging one profile pit and three percolation holes, as indicated. The materials encountered in the profile pit consisted of 1 -foot of a clayey root zone, underlain by sandy clay to the maximum depth explored of 8 feet. Groundwater or bedrock was not encountered. Three percolation holes were dug, in the area of the proposed drain field, as indicated. Percolation rates ranged from 10 to 20 minutes per inch (MPI). A 15 MPI rate will be used to design the OWTS. DESIGN SPECIFICATIONS The OWTS design is based on 8 -bedrooms and an average sewage load of 1600 GPD. The installation must include a 2000 -gallon, single -compartment, precast concrete septic tank, to be followed by a 2000 -gallon FASTTM secondary treatment tank. Tank alternatives may be considered. Six gravelless chamber trenches, using `Quick -4' InfiltratorTM chambers, must be installed as Subace Investigation and OWTS Design Project No. 1703 5110110 Page 2 indicated. Each trench must have 1 row of 24 chambers, for a total of 1422 square feet (SF) of infiltrative area, and 144 total chambers. A flow splitter basin, brought to grade must be installed to distribute effluent. Construction must be according to the Pitkin County Environmental Health and Natural Resources Department OWTS regulations, the OWTS Construction Permit provided by Pitkin County Environmental Health and Natural Resources Department, and this design. OPERATION INFORMATION AND MAINTENANCE The surface of the drain field should be seeded upon completion. Vegetation is an important factor in drain field performance. Erosion control should be practiced prior to and during re -vegetation. Geo - fabrics or plastics should not be used over the drain field. No heavy equipment, machinery, or materials should be placed on backfilled drain field. Livestock should not graze on the drain field. Plumbing fixtures should be checked to ensure that no additional water is being discharged to OWTS. For Example, a running toilet or leaky faucet can discharge hundreds of gallons of water a day and harm a drain field. The homeowner should pump the septic tank every two years and clean the effluent filter as needed. Garbage disposal use should be minimized, and non -biodegradable materials should not be placed into the OWTS. Grease should not be placed in household drains. Loading from a water softener should not be discharged into the OWTS. No hazardous wastes should be directed into the OWTS. Mechanical room drains should not discharge into the OWS. The OWTS is engineered for domestic waste only. ADDITIONAL CONSTRUCTION NOTES If design includes a pump, air release valves and weep holes should be installed to allow pump lines to drain to minimize risk of freezing. Excavation equipment must not drive in excavation of drain field due to the potential to compact soil. Extensions should be placed on all septic tank components to allow access to them from existing grade. Precast concrete tanks and distribution boxes should be used, unless plastic or fiberglass is required. Access to all tank compartments and distribution devices is optimal. INSTALLATION OBSERVATIONS ALL SERVICE septic, LLC, and the county must view the OWTS during construction. The OWTS observation should be performed before backfill, after placement of chambers and distribution pipes. Septic tanks, distribution devices, pumps, dosing siphons, and other plumbing, as applicable, must also be observed. ALL SERVICE septic, LLC should be notified 48 hours in advance to observe the installation. Subsurface Investigation and OWTS Design Project No. 1703 5/10/10 Page 3 LIMITS: The design is based on information submitted. If soil conditions encountered are different from conditions described in report, ALL SERVICE septic, LLC should be notified. All OWS construction must be according to the county regulations. Requirements not specified in this report must follow county regulations. The installer should have documented and demonstrated knowledge of the requirements and regulations of the county in which they are working. Please call with questions. Sincerely, ALL SERVICE septic, LLC Timothy R. Petz 3 copies Reviewed Richard H PITKIN COUNTY ENVIRONMENTAL HEALTH DEPARTMENT Percolation Test and Soils Data Form - TABLE 1 - PROJECT 1703 Performed by ALL SERVICE septic, LLC PROFILE PIT Date of Test: 4-27-10 0 - 1' Topsoil, Root Zone, Sandy 1'- 8' Sand, Silty, Angular Rock Fragments, Dense, Moist, Red/Brown Colluvium No Groundwater or Bedrock was Encountered Hole Hole Interval No. Depth (in.) (min.) Measurement at Start of Interval in. Measurement at End of Interval in. Change (in.) Percolation Rate (min./in.) MPI 1 29 20 0.25 1.75 1.50 20 1.75 3.50 1.75 20 3.50 4.50 1.00 20 4.50 5.75 1.25 20 5.75 6.75 1.00 20 6.75 7.75 1.00 20 2 31 20 4.00 6.00 2.00 20 6.00 7.75 1.75 20 7.75 9.00 1.25 fill 20 4.00 5.50 1.50 20 5.50 7.00 1.50 20 7.00 8.50 1.50 14 3 31 20 7.00 9.00 2.00 20 9.00 11.25 2.25 20 11.25 dry fill 20 3.50 5.75 2.25 20 5.75 7.75 2.00 10 20 7.75 dry AVERAGE = 15 OWTS DESIGN CALCULATIONS - for Pitkin Owners Name .. ,".. Parcel ID #-�:. House Size (sq. ft.) ? (75 gpd or 100 gpd) 100 Number of Bedrooms in Main House DXW4 Number of Offices, Libraries, Studies, Similar -sized Rooms in Main House, -711 Number of Bedrooms in Detached Caretaker unit Number of Offices, Studies, Similar -sized Rooms in Caretaker Unit , �• ,, (If the caretaker unit is ATTACHED, treat as if part of main house.) Average Daily Waste Flow 1600 State Review Required? no Perc Rate x (T) Design Flow (Q) = # potential bedrooms X 2 people/bedroom X gpd X 1.5 Q= 2400 Minimum tank capacity 3000 gallons Absorption Area (=Q/5 X SQRT perc rate)(1.4 loading factor) A = 2,603 sq. ft. of absorption area required Absorption Area (=Q/5 X SQRT perc rate) WITH SECONDARY TREATMENT (no loading factor) A= 1,859 sq. ft. of absorption area required Abs. Area w/ loading factor (B25) Trench Bed Quick4 Trench Pipe and Gravel (-10%) 2342 no red. 2603 237 Dosing (-20%) 2082 (-20%) 2082 211 Chambers (-30%) 1822 (-10%) 2342 185 Max Allowable L5m 1301 (-30%) 1822 132 Secondary Treatment Abs Area w/ out loading factor (B28) Trench Bed Pipe and Gravel (-10%) 1673 no red. 1859 170 Dosing (-20%) 1487 (-20%) 1487 151 Chambers (-30%) 1301 (-10%) 1673 132 Max Allowable (-50%) 930 (-30%) 1301 94 212 SETBACK FROM WELL # of feet = 162 SETBACK FROM POND, STREAM OR IRRIGATION DITCH # of feet = 137 SETBACK FROM DRY GULCH # of feet = Quick4 Bed 264 211 237 185 188 151 170 132 N 0' 10 1. 30' 40 Scale: 1' = 20' -T I I I I I I I I I I I I I I I I I I / > \ q Q \ \ 8 • BEDROO \ RESIDENCE , I I I � I / I / F CSDR 35 PIPE / 4" PVC SDR20/PIPE I (1 % FALL BASIN) 9. 14 O TBASIN CRETE SEP C LUENTF TFANK T 4.5 IT /R I I l I ) I � I � I I I \ / I \ / I Y I / I / I I / I / I / I \ / I / I / /' II I I Lam_ i SIX GRA LE.5 TRENCHES. EACH TRENC UAS24'QUICK-4' CHAMBERS, -0R ARC -36 CHAMBERS —. OTAL AREA - 1659 SF TOTAL QUICK -4 CHAMBERS = TOTAL ARC -36 (ALTERNATI OBSER ION�Flfq S / / / / Tank with the Addition of an Effluent Filter - 2000 Grwnd \ /=a)' from Rion Pate caro;age lanae IP of tee a came W ianM Aaplar (wal v Edletl 1- ap d tang IM ) det i Vat eilu EM t aiecnarye Z., tqu0 Lew Rodbtinq R=.narys tlnficae Wet hkt Pone ORENCO BRAND NAME NOT ENFORCED SWEEP 12 WAY CLEANOUT DETAILS (N.T.S) TYPICAL SLIP-ON PVC CAP FINISHED GRADE—t /—SLIP - NOT GLUE SEWER 4" PVC OBERVATION PIPE Outlet I Length 51" 162" LINE - q• Height LINE -4' SCHEDULE INSULATED SCHEDULE 4. MIN 40 OR COPPER 40 P.V.C. 4' SDR TRACER WIRE 35 MAY BE 'QUICK 4' GRAVELLESS FLOW P.V.C. INSTALLED TO (4'x3') PRIOR TO PLACEMENT OF SAND LOCATE LINE IN SDR 35 (1 % min fall to FUTURE DESIGN 8 BEDROOMS (>6000SF) - 100 gals/person x 2 pentonslhed—=1600 GPD LOADING - 1600 GALLONS PER DAY PEAK LOADING = Q = 1600 X 1.5 = 2400 GPD PERCOLATION RATE =t= 15 MINUTES PER INCH (MPI) CALCULATED AREA - ((Q X sqrt t) / 5) =1880 SF PROPOSED AREA - 1860 SF X SIM% REDUCTION =1302 SF TRENCH SPECIFICATIONS WIDTH OF TRENCHES - 3 FEET - 1 CHAMBERS LENGTH OF'QUICK-4' TRENCHES = 96 FEET = 24 CHAMBERS TOTAL NUMBER OF'QUICK4 CHAMBERS =144 TOTAL INFILTRATIVE AREA = 1422 SF SIX TOTAL TRENCHES 4" PVC SDR PIPE — — / (1%F ALL TO TRENCHf3S) Top View OP -1 I � I / � P -2i P-3 / STING HOUSE TO E ISHED > / 4 Rhr C=lnage Eff— FMr Flow Solitter Basin Scale: 31r - I' pp= a iw •Aw tt=Y� aeal". oea�xo.Larepe.l,ro,weasaee•,a DRAIN FIELD CROSS SECTION -TYP. 4" PVC OBERVATION PIPE Outlet I Length 51" 162" LIMIT OF Height EXCAVATION 2.0'MIN V MIN 3.0' MAX 'QUICK 4' GRAVELLESS FLOW CHAMBER SCARIFY SURFACE SPLITTER (4'x3') PRIOR TO PLACEMENT OF SAND 4' PVC PIPES SDR 35 (1 % min fall to PLAN VIEW - TYP. trench) 20" Clear Access 1.5 MicroFAST f O Unit 6" Coupling for Pumping Access •. Digging Spee - Invert I Dimanalona 15' Long x 8' Wide Inlet 56' below inlet In 56' Outlet I Length 51" 162" Width Height 'Meets ASTM C-1227 spec including C-1664-06 for resilient connectors ° • 4000 psi concrete ° o • Delivered complete with internal piping nSITE PLAN / PROPOSED OWS PguadiurnDesign Associates P.O. Box 2844 1" = 20•_0' 323WtsrMAW STitil Glenwood Springs, Colorado 81602 St?rM #:Z(30 pr rr Phone 970.618.5033 ASMNICA'x-ORAM51611 S�IIII�L Fax 303.216.2796 870.61&51588 MOUL,E UL 1 L PIPE b=p Qmm xtems• wI1FaN!PFWp xu ase pool w -ow IStO.a-ue (•na ers-� O a �t Wlbl (Cape at I/r' pldp ae Ahpe TmNen (aero s' ayane eaMl BSERVATION INFILTRATOR(R) OUICK4(TM) CUT SHEET PIPE 12 48' 11 +� FET LN 34' 6" 2' ZJA 34" PVC PIPE TO ENTER IN TOP PORT OF END PLATE PIPE TO ENTER CHAMBER IN TOP PORT OF END PLATE GRAVELLESS CHAMBER 'QUICK -4' 1 4" PVC PIPES 6' MIN SDR 35 Butyl Section View PLATE I 24 CHAMBERS PER TRENCH — 96 FEET n CHAMBER DETAILS L NOT TO SCALE Net Weight Ud Tank Total 4,340 lbs 15.5301bs 19,870lbs ............ n MICROFAST DETAILS aGroFnn —n Um J NOT TO SCALE Palladium Design 240 West Buttermilk Lane \ /fr / ' O Pitkin County, Colorado W/ �/ Project Number. 1703 Sheet 1 of 1 Inlet Side 604 gallons �.dtal Net Weight Ud Tank Total 4,340 lbs 15.5301bs 19,870lbs ............ n MICROFAST DETAILS aGroFnn —n Um J NOT TO SCALE Palladium Design 240 West Buttermilk Lane \ /fr / ' O Pitkin County, Colorado W/ �/ Project Number. 1703 Sheet 1 of 1 o o - I I � I I I S Z bp ,I/ NOTE: TOPO. 8154'-0" = 100'0" ARCHITECTURAL CB73 R SUITE #200 ASPEN. COLORADO 81611 970-618-5588 M O w U o zWQ wZrr ) U1 U W z rl m U t LLZ } 00 r IL I^WI W ISSUE: PERMIT! 01-2610 4) PLAN NORTH MAIN LEVEL REFERENCE PLAN SHEET NO. scuF: ve"_l,o^ A3.2 NOTE: TOPO. 8154-0" = 1 00'-0" ARCHITECTURAL mm 13!Wl.. SUITE #200 ASPEN. COLORADO 81611 970.618-5588 M inI U o W z a 0 J 0 U� U W >: D m0 Z }co Fy n 0. PLAN NORTH LOWER LEVEL REFERENCE PLAN SHEET NO. A3. 1 Jan e2 2010 8:4361+ lel.':�:; ,.-�;:, •.r 0 LASERJET 3200 • Butterrw:k ?`vletrapai Car: District j i r^^r.�apt�ter EZ3ad. �uxrx -F�I�1 +Aper Col xado 8161 It I'r-.• `iaxox Fuad um Desi Assatiat±s i'? 1,4'nt `.lain 5tteei Suitt 200 Aspen. Col,:radv 9t611 DeAr Mike n„t{Y^.za ��lJ:iite.y_i. r iSty afY4 Rc: Water Service tic $t) Banetsritb Limt .r.. Sazz�a_z. S�.zxawi IV -Amzk 9."Mr ?anuay 2tl. 201Q Th --s iener will 000firm that the Mperty at Sa Hutt-r.u:lk Lane lies whc ty sv0lin the gate Bourdanes of the Sune*T.nilk .Mttrw)ita:-i Dist*izL The Tl v errniA M tx-� Disriol xo4idcs pQtabie wafter wrvicc to propet?:es within the District through a Calpra& State approvv-- publi: vcattr s,stet n Tl a s:^stern identification rumbec is PU-SID k CO 0149160 and around water some has been ediudicated U cler Case has. 04CA'305 and 01CW28 in Water Court DivWon 5. •nd the Nater supply meets or excee3a all federal and state water quality standO& and a fully opmational pumpxg. *reamwnt and distri3istitxi system is in Ylacc 10ttl .er wate-. tO all prrpcm,cs exigible for service frogs+ the Distri- no 30 Buttt:'ratik Lane Propert}" is cligibit fx water service f*om the District. tx.t pnot to actua KatCr dtiivenes, tl#0 pcoFt*ty 04AM i tt u% 11:ctnp etz 8 water se 3ice applA;tt1C2 . q{tarltifying the servi.e la el requrszed, 7) tender paymer:t of as appropriate :ets and a irc?u ding tap fees (if requiredt. Heat• Vehicle Use fees, ti;sitec rght :ees aid strv'cc a*sd water !iiia cwist-uction and TwttK inspection fees'. azt! 3) install a Mer -o District appmvtd aatzr semice liar and eiecr-anic water meter. Cernin resnWIons on water use amly- `lite 80 Buttertndi Lane Fruperpy is a1w eligible to access t:-ust roads, and use of nht roads during, c instructior+ b< heavy vchic'a it pewit tttd fo low,ng tse pay'rr_en*. of a Wma-q Vehicle Use Fee. lbs fee is mculated b1, and paid to, the Yetro District for tate;A:W.-rated weer csuf:i by heavy trues and equipment eornxnonly used to buaki ho;r-es ir. tN's arm" Any pnYposed cut to ar.y district read and all access paints ii.e drivc%vWs) mus: be pre -approve by cne District. All p-opem owners writhm t'te But-amilk Metropol An District must amply with all auks an- ,eSulstiors of the Ristrici as adeand d periodically- changed by ft District's So 'd of Directors. vA#er Tal. d`•1� 3�'; tAA-- 4,13'44..47•=3 W1 twaerra Lager -. jib= m -Ila 0.2 TITISSNAMAW r,•s.. . ram �t !!t A t 0 some ivAR a sit COT r ria rrr r r..ar .Q wv ` l N SAUNA 0x Ty I' n .7c �5% , ; 1IX T % SUPS I 6 ADMINISTRATIVE DECISION OF THE COMMUNITY DEVELOPMENT DIRECTOR OF PITKIN COUNTY, COLORADO, APPROVING THE ANDERSON 1041 HAZARD REVIEW Decision No.1;q-2007 RECITALS I . Daryl Anderson ("Applicant") has applied to the Community Development Director (hereafter "Director") for 1041 Hazard Review approval to establish a building envelope with vested rights. 2. The Lot is located at 0080 Buttermilk Road and is specifically described in Exhibit A. 3. The property is zoned AR -10 and contains approximately 4.5 acres. 4. The Applicant submitted a complete application prior to July 6, 2006, therefore, the application is being considered pursuant to the 1994 Land Use Code, as amended. 5. The Director finds that the wildfire hazard within the envelopes can be mitigated, and that the request is in compliance with the Code. THE DIRECTOR DOES HEREBY APPROVE the Anderson 1041 Hazard Review subject to the following conditions, which shall run with the land and be binding on all successors in interest: The Applicant shall adhere to all conditions and material representations made in the application and public meetings except as amended herein. 2. Prior to submission of any future building permit applications, the Applicants shall be required to submit for approval by the County Attorney and Community Development Site Plan in accordance with 1 -and Use Code Section 5-70-040, which shall depict the envelopes. The above referenced approvals shall be a condition precedent to finalization and recordation. 3. Prior to issuance of any building permits for the new residence, the Applicant shall: A. Complete a fireplace/woodstove registration form with the Community Development Department, if necessary. B. Submit a drainage and erosion control plan for review and approval by the County Engineer. C. Submit a construction management plan for review and approval by the County Engineer showing the locations of staging, material storage and employee and construction traffic parking. D. Pay the applicable road and housing impact fees. E. Provide proof that the existing residence has been removed/demolished. F. Provide a letter of compliance from the Buttermilk Metro District regarding water service to the parcel. 4. The Applicant shall comply with the following to mitigate impacts on wildlife: A. Dogs shall be leashed or kenneled. 534909 01.55E JANICE K VOS CAUDILL PITKIN COUNTY CO R 0.00 D 0.00 Hearing Officer Determination No.Oq-20% Page 2 B. Fencing outside of the building envelope shall comply with the wildlife fencing standards in the Land Use Code. C. Instal I and use an approved bear -proof trash container as required by the County. D. Maintain native vegetation outside of the building envelope. E. Avoid fruit -bearing trees and shrubs in any landscaping. The Applicant shall comply with the following landscaping and wildfire defensible space mitigation standards as can be accomplished within the boundaries of the property: A. From the edge of any structure, or deck projection, for a distance of 15', vegetation shall be less than 6" in height, with the exception of if the Applicant desires to maintain or plant one or more ornamental trees, in which case vegetation shall be less than 6" for 15' beyond the drip line of the expected mature size of the trees. B. Beyond the 15' area, and up to 45' from the edge of any structures down the slope, and 35' cross slope and up slope maintain grasses to less than 6", and thin and cluster brush and trees. Lower limbs of trees and bushes shall be pruned to %z the height of the trees, or 10% whichever is less. Clusters of trees and bushes or shrubs shall be separated from each other, and from those beyond the perimeter by a distance of 2'/z times the height of the mature vegetation. The diameter of clusters at their crown shall not exceed 2 '/i times the height of the mature vegetation. C. All thinned snowberry, serviceberry or chokecherry stumps must be painted with Garlon, (or equivalent) herbicide to prevent aggressive re -sprouting. D. All branches which extend over the roof eaves shall be trimmed and all branches within 15 feet of the chimneys shall be removed. E. All deadfall within the 60 -foot perimeter shall be removed. F. The Applicant shall be responsible for the continued maintenance of the defensible space vegetation requirements. 6. The Applicant shall comply with the following additional wildfire mitigation standards: A. Roofs shall be constructed with a Class A roof covering on a Class A assembly as defined in the International Building Code (TBC) Section 1505.2. Wood shake/shingle roof coverings are prohibited. Roofs with less than a 3:12 pitch are not permitted unless they comply with the following: I . All roof coverings shall be noncombustible materials and installed on a Class A roof assembly. 2. All roof coverings shall have a surface that shall facilitate the natural process of clearing the roof. 3. All roof designs shall facilitate the natural process of clearing roof debris. Protrusions above the roofline, such as parapets, shall be prohibited. 4. Roofs shall be installed as required by the adopted building code and shall have a minimum slope of 1:48. 5. All roof designs, coverings or equivalent assemblies shall be specifically approved by the Fire Marshall prior to submittal of a building permit application. B. Projections: 534909 III�������IIIIIIIIII I 02/28/2007 4 III III IIII 7 e1:55; JANICE K VOS CAUDILL PITKIN COUNTY CO R 0.00 D 0.00 J 440 11111 1�1111111111111111111111111111111111111 Pa:az4 $9�9 01:55F Administrative Decision No()!a-2007 JANICE K VOS CAUDILL PITKIN COUNTY CO R 0.00 0 0.00 Page 3 1. Projections at the roofline (which includes, but are not limited to: eaves, cornices, soffits and roofs over open decks) shall be sheathed with materials approved for one-hour fire -resistive construction; 2. For projections below the roofline (including, but not limited to: exterior balconies, decks, porches, and bay windows which extend over a flat or sloped surface), the open space between grade and the underside of projections below the roofline shall be enclosed by solid, vertical walls. These walls shall be constructed with materials approved for one-hour fire -resistive construction on the exterior side of the wall, and shall extend from the top of grade to the underside of the floor decking or walls of the projection, AND: 3. Any porch or deck or projection shall be void of vegetation below it, and areas below such projections shall be protected from accumulation of vegetation materials by placement of a vegetation barrier covered with rocks or gravel, or by coverage with concrete or stone. Walls underneath projections shall be constructed with materials approved for 1 hour fireresistive construction on the exterior side of the wall. C. Any windows shall be tempered glass. Doors on this side (if any) shall be non- combustible, or I Y4" solid wood. D. Exterior Wails and Siding shall have a minimum one-hour fire resistive. E. Foundations, skirting and crawl space openings shall be fully enclosed and constructed with materials approved for 1 hour fire -resistive construction on the exterior side of the walls and shall extend from the top of grade to the underside of the floor decking or walls. F. Stilt foundations shall be fully enclosed and constructed with materials approved for 1 hour fire -resistive construction on the exterior side of the walls and shall extend from the top of grade to the underside of the floor decking or walls (not including porches, patios, etc.). G. Vents shall be screened with corrosive resistant wire mesh with mesh 1/4 inch maximum. H. Firewood/wood piles shall be stacked on a parallel contour a minimum of 15 feet away from the structure. 1. Fences shall be kept clear of brush and debris. J. Wood fences shall not connect to the structure. K. Any outbuildings or additional structures shall adhere to the same standards as structures. L. Fuel tanks shall be installed underground with an approved container. M. Propane tanks shall be installed according to NFPA 48 standards and on a contour away from the structure with standard defensible space vegetation mitigation around any above- ground tank. Any wood enclosure around the tank shall be constructed with materials approved for 2 hour fire -resistive construction on the exterior side of the walls. N. Each structure shall have a minimum of one 10 pound approved ABC fire extinguisher placed in a visible and accessible location. 0. Addresses shall be clearly marked with 2 inch non-combustible letters and shall be visible and installed on a non-combustible post. P. All flammable materials shall be stored on a parallel contour a minimum of 15 feet away from any structure. Q. Swimming pools shall be accessible to Fire Department vehicles. R. Any fire department recommendation for individual structure water supply and storage shall be accessible to fire department vehicles from the exterior of the structure through a Administrative Decision No.60-2007 Page 4 Fire Department approved mechanism (such as a fire hydrant). The amount of storage capacity shall be determined by the fire protection district. S. New utility lines shall be buried. T. Roofs and gutters shall be kept clear of debris. 7. No development, including grading, excavation, fill placement, berming, landscaping, entry or ranch gates, and vegetation removal or disturbance shall occur outside of the approved building [and/or] access envelope except for wildfire mitigation. Construction, staging, parking, utility and driveway extension and maintenance shall occur within approved building envelope, or access envelope. S. Prior to commencement of any earthmoving or construction activity, the Applicant shall stake the corners of the building envelope and install construction fencing around the perimeter of the building envelope. The fencing shall remain in place until issuance of Certificate of Occupancy. No vegetation shall be damaged or removed outside the building envelope. 9. Any areas disturbed outside the building envelope must be revegetated with native vegetation according to a revegetation plan submitted by the Applicant and approved by the County prior to issuance of a Certificate of Occupancy, 10. The exterior of the residence shall be finished in the natural earth tones of the immediate vicinity, as represented in the application. Roof and siding materials shall be non -reflective. Color and material samples shall be provided to Community Development for approval prior to issuance of building permits. H. At time of building permit submittal a landscape plan shall be submitted and approved by Community Development prior to issuance of a building permit. A specific visual mitigation plan for the southern retaining wall for the main residence and the retaining associated with the access shall be submitted as part of the landscape plan. Included in the plan shall be retaining wall design and coloration, as well as methods for minimizing the visual impacts. 12. The Applicant shall comply with the requirements of the Aspen Fire Protection District 13. Statutory vested rights for the approval contained herein are granted pursuant to the Pitkin County Land Use Code and Colorado Statutes, subject to the exceptions set forth in Pitkin County Land Use Code, § 4-140 and C.R.S., § 24-68-105. The statutory vested rights granted herein shall expire on APPROVED by the Director, this (S� day of ;:4--±3, 2007. tr Cindy Houben, Community Development Director P 18406 PID# 273503400036 534909 1�1�11 ��111 02D/2812007 01:551 �1CAUD a 00 D JRNICf K V05 CAUOiLL A[TKIN CdUNTY CO R 0. I IIIII lllll 111111 IfID 111111 IIIIIII�IIII�I IIIIIIII 93/13/2007 535368 3 ; I of 01;441 JANICE K VOS CAUDILL PITKIN COUNTY CO R 0.00 D 0.00 ADMINISTRATIVE DECISION OF THE COMMUNITY DEVELOPMENT DIRECTOR OF PITKIN COUNTY, COLORADO, APPROVING THE ANDERSON 1041 HAZARD REVIEW Decision Noa-2007 RECITALS 1. Daryl. Anderson ("Applicant") has applied to the Community Development Director (hereafter "Director") for 1041 Hazard Review approval to establish a building envelope with vested rights. 2. The Lot is Iocated at 0080 Buttermilk Road and is specifically described in Exhibit A. �— 3. The property is zoned AR -10 and contains approximately 4.5 acres. 4. The Applicant submitted a complete application prior to July 6, 2006, therefore, the application is Ibeing; considered pursuant to the 1994 Land Use Code, as amended. 5. The Director finds that the wildfire hazard within the envelopes can be mitigated, and that the request is in compliance with the Code. THE DIRECTOR DOES HEREBY APPROVE the Anderson 1041 Hazard Review subject to the following conditions, which shall run with the land and be binding on all successors in interest: The Applicant shall adhere to all conditions and material representations made in the application and public meetings except as amended herein. ^71 2. Prior to submission of any future building permit applications, the Applicants shall be required to submit for approval by, the County Attorney and Community Development Site Plan in accordance V with Land Use Code Section 5-70-040, which shall depict the envelopes. The above referenced approvals shall be a condition precedent to finalization and recordation. 3. Prior to issuance of any building permits for the new residence, the Applicant shall: A. Complete a fireplace/woodstove registration form with the Community Development Department, if necessary. B. Submit a drainage and erosion control plan for review and approval by the County Engineer. C. Submit a construction management pian for review and approval by the County Engineer showing the locations of staging, material storage and employee and construction traffic parking. D. Pay the applicable road and housing impact fees. E. Provide proof that the existing residence has been removed/demolished. F. Provide a letter of compliance from the Buttermilk Metro District regarding water service to the parcel. 4. The Applicant shall comply with the following to mitigate impacts on wildlife: A. Dogs shall be leashed or kenneled. II IIIIII11111II� III IIII IIII � Page I of 01:55f i 111111 IIII 111111 II I I I I JANICE K V05 CAUDILL PITKIN COUNTY CO R 0.00 D 0.00 IHH���!!I 535368 Pege: 2 of 5 llNIJ 0312ANIC£K iLLPITKIYO 3/2007 01.441 Hearing Officer Determination Nom -200 R 0.00 0 0.00 Page 2 B. Fencing outside of the building envelope shall comply with the wildlife fencing standards in the Land Use Code. C. Install and use an approved bear -proof trash container as required by the County. D. Maintain native vegetation outside of the building envelope. E. Avoid fruit -bearing trees and shrubs in any landscaping. 5. The Applicant shall comply with the following landscaping and wildfire defensible space mitigation standards as can be accomplished within the boundaries of the property: A. From the edge of any structure, or deck projection, for a distance of 15', vegetation shall be less than 6" in height, with the exception of if the Applicant desires to maintain or plant one or more ornamental trees, in which case vegetation shall be less than 6" for 15' beyond the drip line oFthe expected mature size of the trees. B. Beyond the 15' area, and up to 45' from the edge of any structures down the slope, and 35' cross slope and up slope maintain grasses to less than 6", and thin and cluster brush and trees. Lower limbs of trees and bushes shall be pruned to 1/2 the height of the trees, or 10', whichever is less. Clusters of trees and bushes or shrubs shall be separated from each other, and from those beyond the perimeter by a distance of 2'/z times the height of the mature vegetation. The diameter of clusters at their crown shall not exceed 2 '/2 times the height of the mature vegetation. C. All thinned snowberry, serviccberry or chokecherry stumps must be painted with Garlon, (or equivalent) herbicide to prevent aggressive re -sprouting. D. All branches which extend over the roof eaves shall be trimmed and all branches within 15 feet of the chimneys shall be removed. E. All deadfall within the 60 -foot perimeter shall be removed. F. The Applicant shall be responsible for the continued maintenance of the defensible space vegetation requirements. 6. The Applicant shall comply with the following additional wildfire mitigation standards: A. Roofs shall be constructed with a Class A roof covering on a Class A assembly as defined in the International Building Code (IBC) Section 1505.2. Wood shake/shingle roof coverings are prohibited. Roofs with less than a 3:12 pitch are not permitted unless they comply with the following: 1. All roof coverings shall be noncombustible materials and installed on a Class A roof assembly. 2. All roof coverings shall have a surface that shall facilitate the natural process of clearing the roof. 3. All roof designs shall facilitate the natural process of clearing roof debris. Protrusions above the roofline, such as parapets, shall be prohibited. 4. Roofs shall be installed as required by the adopted building code and shall have a minimum slope of 1:48. 5. All roof designs, coverings or equivalent assemblies shall be specifically approved by the Fire Marshall prior to submittal of a building permit application. B. Projections: 111534 N 11111111111111111111111111111111111111111 g8809111101:551 JANICE K VOS CAUDILL PITKIN COUNTY CO. R 0.00 D 0.00 to W 5 III III oil 1111111 /4909 01.551 I INIII IIIA f1N I Administrative Decision No()C -2007 JANICE K VOS CHILL AITKIN COUNTY CO R 0.08 D 0.00 Page 3 1. Projections at the roofline (which includes, but are not limited to: eaves, cornices, soffits and roofs over open decks) shall be sheathed with materials approved for one-hour fire -resistive construction; 2. For projections below the roofline (including, but not limited to: exterior balconies, decks, porches, and bay windows which extend over a flat or sloped surface), the open space between grade and the underside of projections below the roofline shall be enclosed by solid, vertical walls. These walls shall be constructed with materials approved for one-hour fire -resistive construction on the exterior side of the wall, and shall extend from the top of grade to the underside of the floor decking or walls of the projection, AND: 3. Any porch or deck or projection shall be void of vegetation below it, and areas below such projections shall be protected from accumulation of vegetation materials by placement of a vegetation barrier covered with rocks or gravel, or by coverage with concrete or stone. Walls underneath projections shall be constructed with materials approved for 1 hour fireresist'Ive construction on the exterior side of the wall. C. Any windows shall be tempered glass. Doors on this side (if any) shall be non- combustible, or 13/4" solid wood. D. Exterior Walls and Siding shall have a minimum one-hour fire resistive. E. Foundations, skirting and crawl space openings shall be fully enclosed and constructed with materials approved for 1 hour fire -resistive construction on the exterior side of the walls and shall extend from the top of grade to the underside of the floor decking or walls. F. Stilt foundations shall be fully enclosed and constructed with materials approved for 1 hour fire -resistive construction on the exterior side of the walls and shall extend from the top of grade to the underside of the floor decking or walls (not including porches, patios, etc.). G. Vents shall be screened with corrosive resistant wire mesh with mesh '/4 inch maximum. H. Firewood/wood piles shall be stacked on a parallel contour a minimum of 15 feet away from the structure. I. Fences shall be kept clear of brush and debris, I Wood fences shall not connect to the structure. K. Any outbuildings or additional structures shall adhere to the same standards as structures. L. Fuel tanks shall be installed underground with an approved container. M. Propane tanks shall be installed according to NFPA 48 standards and on a contour away from the structure with standard defensible space vegetation mitigation around any above- ground tank. Any wood enclosure around the tank shall be constructed with materials approved for 2 hour fire -resistive construction on the exterior side of the walls. N. Each structure shall have a minimum of one 10 pound approved ABC fire extinguisher placed in a visible and accessible location. O. Addresses shall be clearly marked with 2 inch non-combustible letters and shall be visible and installed on a non-combustible post. P. All flammable materials shall be stored on a parallel contour a minimum of 15 feet away from any structure. Q. Swimming pools shall be accessible to Fire Department vehicles. R. Any fire department recommendation for individual structure water supply and storage shall be accessible to fire department vehicles from the exterior of the structure through a 535368 Paque: 3 of 5 11IN 111111111111111111111111103/ . 13/2887 01.441 JANICE K VOS CAUDILL AITKIN COUNTY CO R 0.00 0 0,08 535368 Page: 4 of S 83/13/2 Administrative Decision No.�-2007 JANICE K VOS CAUDILL PITKIN COUNTY c0 R 0.00 D0.00 1.441 Page 4 Fire Department approved mechanism (such as a fire hydrant). The amount of storage . capacity shall be determined by the fire protection district. S. New utility lines shall be buried. T. Roofs and gutters shall be kept clear of debris. 7. No development, including grading, excavation, fill placement, berming, landscaping, entry or ranch gates, and vegetation removal or disturbance shall occur outside of the approved building [and/or] access envelope except for wildfire mitigation. Construction, staging, parking, utility and driveway extension and maintenance shall occur within approved building envelope, or access envelope. 8. Prior to commencement of any earthmoving or construction activity, the Applicant shall stake the corners of the building envelope and install construction fencing around the perimeter of the building envelope. The fencing shall remain in place until issuance of Certificate of Occupancy. No vegetation shall be damaged or removed outside the building envelope. 9. Any areas disturbed outside the building envelope must be revegetated with native vegetation according to a revegetation plan submitted by the Applicant and approved by the County prior to issuance of a Certificate of Occupancy. 10. The exterior of the residence shall be finished in the natural earth tones of the immediate vicinity, as represented in the application. Roof and siding materials shall be non -reflective. Color and material samples shall be provided to Community Development for approval prior to issuance of building permits. H. At time of building permit submittal a landscape plan shall be submitted and approved by Community Development prior to issuance of a building permit. A specific visual mitigation plan for the southern retaining wail for the main residence and the retaining associated with the access shall be submitted as part of the landscape plan. Included in the plan shall be retaining wall design and coloration, as well as methods for minimizing the visual impacts. 12. The Applicant shall comply with the requirements of the Aspen Fire Protection District 13. Statutory vested rights for the approval contained herein are granted pursuant to the Pitkin County Land Use Code and Colorado Statutes, subject to the exceptions set forth in Pitkin County Land Use Code, § 4-140 and C.R.S., § 24-68-105. The statutory vested rights granted herein shall expire onZZ Iia APPROVED by the Director, this day of 2007. _C"& tC Cindy Houben, Community Development Director P 184-06 P1D# 273503400036 { 534909 0ag 2/28/2807 01'.55; 0.00 JRNTCE K VOS CAUDILL PITKIN COUNTY CO R 0.00 EX13[iiITA tVLIW;kjjl A tract of land situated in Lot 13, Section 3, Township 10 South, Range 85 West of the 6m Principal Meridiary beginning at a point from which the South one-quarter corner, Section 3, Township 10 South, Range 85 West of the 6i° Principal Meridian, bears S. 08'54' W. a distance of 623.20 feet; Thence S. 50"1�2' B. a distance of 408.5 feat; thence N. 05'36'15" E. a distance of 99.72 feet; thence N. 15045'15" W. a distance of 192.95 feet; thence N. 28'39'40" W. a distance of 209.66 feet; thence S, 39'4-0'W. a distance of 273.08 felt to the place of beginning. PARCEL 2: A trail ofland situated in Lot 13, Section 3, Township 10 South Range, 85 West of the 6's Principal Meridian, beginning at a point on the West line of Lot 13 from which the South one-quarter corner of Section 3, Township 10 South., Range 85 West of the & principal Meridian bears S. 00'28' W 690.44 feet; thence S. 50'32'E. 526.10 feet to a60 foot access road; thence S. 05'36'15"W. 39.19 feet along the West line ofthe said 60 foot right of way to the South lint of said Lot 13; thence S. 89'22 W. 405.70 feet along the South line of Lot 13 to the Southwest comer of said Lot 13; thence N. 00'28' E. 377.89 feet along the West lice of said Lot 13 to the point of beginning. County of Pitkin, State of Colorado 11l1M1111111 DIN 111111111 HE 111111111111141111 IN 4333SZ 07/11/Wa8 0I.3EP AMOMM DAVIS STLY2 S of 6 R 30.00 0 0.08 N 0.00 FMIN COUNTY Co F:,wenoC=0P.wnc ce.9ma 535368 Page; 5 of 5 r 011f 1!Hll��1�f 03, . 13/2007 81 44 JANIM K VOS CAUDILL PITKIN COUNTY CO R 0.00 0 0.00 Parcel #273503400036 rJ MEMORANDUM To: Michael Kraemer, Planning Department From: Nancy MacKenzie, Environmental Health & Natural Resources Department Date: September 7, 2007 Re: West Buttermilk LLC Special Review for a Caretaker Dwelling Unit and Site Plan Review (PID 2735-034-00-036; Case P087-07) SUMMARY" OF RELEVANT PARTS OF APPLICATION: The applicant is seeking approval of a detached CDU with GMQS Exemption and Vested Rights and Site Plan Review. DISCUSSION: A site visit was conducted on September 4, 2007 by Nancy MacKenzie and Michael Kraemer from the Community Development Department. Glenn Horn was on site representing the owner. The Pitkin County Environmental Health & Natural Resources Department has reviewed the details of the West Buttermilk LLC application under the authority of the Pitkin County Land Use Code and the Pitkin County ISDS Regulation and has the following comments. ADEQUATE PROVISION FOR WATER NEEDS: 1-60-310: Identification of a property's water supply is necessary for siting of an onsite wastewater treatment system ("OWTS") due to setback requirements. The application indicates that this parcel is served by the Buttermilk Metro water system, which is typical in this area. The Metro District is responsible for determining if the District has enough water to serve the project. Administrative Decision No. 09-2007of the Community Development Director of Pitkin County requires a letter of compliance from the Buttermilk Metro District regarding water service to this parcel prior to issuance of any building permits. This Department has the same requirement prior to issuance of an OWTS permit. SEWAGE TREATMENT: 1-60-320: There is an existing OWTS installed in October 2003 under this Department's Permit #03061 which was sized for 4 bedrooms. It serves the current residence, which is proposed to be demolished and replaced with a 1,000 sf CDU. The OWTS has one 2,000 gallon septic tank and gravity feed to a gravelless chamber bed with six rows of fourteen chambers for a total of 1,302 sf of area. During the site visit the location of the bed was obvious but not the tank, since no lids to the septic tank were visible. Due to the recent installation of this system, it would be possible to reuse this system for a new caretaker dwelling unit of <2,000 sf and no more than 4 bedrooms under the following conditions: A new OWTS permit must be obtained for this system to serve the new CDU. To secure that new permit: 1. The tank must be located and pumped. 2. All components of the system must be inspected by an engineer knowledgeable in septic system design to insure the integrity of the components of the system and that the system is functioning as designed. This shall include exposing the distribution box and the inlet ends of the pipes. Observation pipes were not visible during the site visit and these must be located or re -installed. The system must meet all setback distances as required in the Pitkin County OWTS regulations. The development intent for this parcel is to construct up to a 14,000 sf house, in addition to the 1,000 sf CDU. No visible constraints on this parcel for locating a new OWTS were observed during the site visit. There were no observed irrigated areas, irrigation ditches, rivers, streams, ponds, gulches, wetlands or riparian habitat. However, the driveway, slopes, CDU and the area taken up by a 14,000 sf main house will limit a suitable area for siting the soil absorption component of the OWTS for the main house.' This Department strongly recommends that the applicant prepare the OWTS design for the main house in consort with siting of the CDU and the OWTS for the CDU. For example, previous soil data for this parcel indicated a 40 mpi percolation rate for the soil. A six bedroom 14,000 sf house will require an area 48 ft X 100 ft for the absorption area. This size assumes six 3 -ft wide trenches, 6 ft apart and a 50% reduction allowed for use of a gravelless chamber system.