HomeMy WebLinkAboutpitkin.eh.273503400039 (2010) Cliffhouse Restaurant-Patrol HutCOLT N Permit #: 10009A SITE WASTEWATER TREAT I.. ;NT SYSTEM (OWTS) CONSTRUCTION PERMIT 0405 Castle Creek Road, Suite 10 - Aspen, CO - 81611 Phone: 970.920.5070 Fax: 970.920.5077 Parcel ID #: 2735-034-01-001 Permit Issued: ❑NEW ®REPAIR ❑REMODEL/ADDITION ❑TANK ONLY ❑FIELD ONLY ❑AMENDMENT Owner(s): Aspen Skiing Company c/o Kevin Hagerty, Mountain Manager Property Address: 0319 Buttermilk Summer Road (Cliffhouse Restaurant) Legal Description: Size of Lot: Size of Building: Acres Sq. Ft. Detached Accessory Unit: ❑YES ®NO Size of Accessory Unit: Cliffhouse Restaurant - 275 seats a Iso See c-jC­S Ca -h -o l Sizing based on historic water records not exceeding flows of 1999 galls Designed By: Schmueser Gordon Meyer Project #: Phone #: 970-945-1004 Mailing Address Email Address: briane@sgm 2010.335.001 118 West Sixth Sq. Ft. tia l-�� � 1►t I I I - Dated: July 6, 2010 -eet. Suite 200 Fax # 970-345-5948 Perc Rate: 27 mpi Profile Hole Depth: Depth to Groundwater or Bedrock: Minimum Tank Capacity: 3750 gallons Minimum Absorption Area: 2182 sq ft w/ 50% reduction This OWTS Construction Permit is approved on the condition of compliance with the engineer design as submitted with the application and the specifications cited above. Changes must be approved by this Department and the engineer prior to construction. This system will consist of one 2000 gallon two compartment grease interceptor followed by two 2000 gallon single compartment tanks with an effluent filters on the outlets near the restaurant. The effluent will travel a significant distance to a,1.5Wgallon tank with a duplex pump system. An automatic distributing valve will be used to distribute effluent to one of two fields; one on Westward Ho and one on Teaser. Designation of the in -use field will be determined through an operation and maintenance agreement. Each field will consist of 15 gravelless chamber trenches with 14 Quick 4 chambers in each trench for a total of 225 chambers. In each field, 3 trenches will be connected via manifold, per engineer design specifications. There must be at least 6 feet of undisturbed soil between each trench. This Permit must be kept on-site during installation. The engineer must do a final inspection of the installation and submit an "as -built" letter to this Department within 30 days of the final inspection, unless a longer period of time has been agreed upon, in writing. This Department must also be called for the final inspection with a minimum of 48 hours notice. ystem and physical features shall conform to the requirements of the Pitkin County OWTS Minimum horizontal distances between components of the s Regulation. ing for regular inspection, cleaning, and maintenance of the system by qualified personnel, in This Permit is conditioned upon the property owner(s) provid accordance with the manufacturer's recommendations and the requirements of the Pitkin County OWTS Regulation. THIS PERMIT IS EXPRESSLY CONDITIONED UPON COMPLIANCE WITH ALL REQUIREMENTS OF THE PITKIN COUNTY OWTS REGULATION, INCLUDING BUT NOT LIMITED TO THOSE CONDITIONS SPECIFIED ABOVE. _:I -__r Dormiccinn i¢ h,=rmhv Plans and specifications for the proposed ovv 15 nave peen revieweu d1lu cl lolu -u--- given to the property owner(s) to perform the work indicated in accordance with the Pitkin County OWTS Regulation. This Permit will expire 1 year from the date of issuance unless construction on the system has commenced. An "as -built" drawing must be submitted and approved by EH/NR before final approval of the system will be issuedY Issued By: Installer: License #: Date: SZ/U / / v Expires: 5/IJ Reactivation Authorized by: �, ❑ Date: New Expiration Date: Fee paid Final Approval r sued B : H ////I,//o / lI i i n ONSITE WASTEWATER TREATM,.4T SYSTEM (OWTS) CONSTRUCTION PERMIT APPLICATION Fri/NR 0405 Castle Creek Road, Suite 10 • Aspen, CO • 81611 Phone: 970.920.5070 Fax: 970.920.5077 Parcel ID# (available from the Pitkin County Assessor's Office 2735 104 0000 1 970-920-5160 or at www.pitkinassessor.orq): Purpose of Permit: ❑ NEW W REPAIR DUE TO FAILURE ❑ REMODEL/ADDITION ❑ TANK ONLY ❑ FIELD Cost of System Repair or Remodel/Addition (approximate): $175,000 Property Address: Buttermilk Ski Area - US Forest Service Lease Land Possessory Lot: Block: Filing: Subdivision: N/A N/A N/A N/A Property Owner(s)*: Aspen Skiing Company Owner's Mailing Address: P.O. Box 1248 Home Email Address: mvogele@aspensnowmass.com City, State, Zip: Aspen, CO 81612 Business Phone: N/A (970)925-1220 *Contact information must be provided for the owner signing this application. Primary Contact Person/Applicant (if not owner): Company: Aspen Skiing Company Mark Vogele Contact/Applicant Mailing Address: City, State, Zip: P.O. Box 1248 Aspen, CO 81612 Cell Phone: 30 5019 Business Phone: 9 (970)923-8759 Fax Number: Email Ad( (970) 923-9617 Building Permit # (if applicable): N/A Repair to existing OWTS at Cliffhouse Restaurant at the top of Buttermilk Ski Area. Lot Size (in acres): Buttermilk US Forest Service Lease Land Possessory Size of Building (square feet): Number of Potential Bedrooms: 12,149 square feet N/A Detached Accessory Unit? ❑YES ME NO Size of Accessory Unit (square Number of Potential Bedrooms In or Fixture List for the Accessory Unit: N/A N/A .corn Water Source: Q PRIVATE WELL ❑SURFACE WATER ❑SPRING COMMUNITY/PUBLIC WATER SYSTEM Name of Community/Public Water System (if applicable): Aspen Skiing Company Well Permit Holder - See attached documents Engineering Firm: Job Number: Phone Number: Fax Number: Schmueser Gordon Meyer 2010-335-001 (970) 945-1004 (970) 945-59 48 Mailing Address: City, State, Zip: I 118 W. 6th St. Ste. 200 Glenwood Springs, CO 81601 PLEASE READ BEFORE SIGNING: I certify that the above information is complete and accurate and that I have provided complete and accurate information in all of the documents included in my application package. I acknowledge that EH/NR may revoke any permit I am issued if my application is found to contain any inaccurate, false, or misleading information. I understand that no construction may be undertaken on an OWTS until an OWTS Construction Permit is issued. Owner Signature (Required): Aspen Skiing Company - David Corbin Vice President 7/21/2010 Date: / Applicant Signature: n „' ^ m y // l =ICE USE ONLY I by EN/HR Staff: Fee &Receipt #: Date: 102�_dc 002- � Marcn 8, 2008 IVEW REG fice-Admin\Forms\OWTS Const Forms\OWTS constr ction permit application As Updated 10/7/08 SCHMUESER I CORDON I MEYER `w E N G I N E E R S j S U R V E Y O R S November 07, 2010 Mark Vogele Construction /Planning Manager SkiCo Planning Department P. O. Box 1248 Aspen, CO 81612 Subject: OWTS Installation Observation Cliff House Restaurant Buttermilk Mountain Aspen, Colorado 81611 Job# 2010-335.001 G t.t-.1J'.1'Cilil) 1 18 WEST SIXTH STREET, SUITE ZOO GLENWOOD SPRINGS. CO 8 1 601 970,94 5. 1 004 970.945.5948 FAX Mark, As required by Pitkin County Health, we have reviewed the wastewater installation at the Cliff House restaurant. The system was designed to serve the restaurant with a seating capacity of 188 persons. The design flows were calculated based on submitted historical water usage data supplied by Brad Hardman of the ski company. Because the system was permitted by the Pitkin County Health Department, the maximum daily flows must be kept under 2000 GPD to avoid the permit violation and triggering a site application with the state. It is recommended that accurate bookkeeping take place as part of the routine maintenance. The system was installed, as per our drawings, with the exception of the pump chamber, which was installed as a 1000 gallon single chambered tank. There was a wooden lid system installed on top of the tank to allow for access until a shed is built. The duplex pump system was installed in the second compartment of the 1000 gallon tank, which discharges through the diversion valve to separate ADV's for each field. For extended life of the system, it is recommended that the fields be rotated on an annual basis. Vehicular traffic should be kept to a bare minimum, if at all. There were ball valves installed on each end of the runs on both fields and contained in irrigation pots, accessible at grade for routine maintenance and, if necessary, field adjustments. It was noted that the Westward Ho field had been tracked by the excavator as part of the final grading, which was approved by SkiCo Staff (Robin) and clearly stated during our discussions that was not to have taken place to prevent soil compaction. The observed components of the OWTS were installed in general conformance with our design and as per the attached as built drawing. The installation observations do not imply a guarantee or warranty of materials or workmanship. 2010-335.0011L20101105\Cliff House OWTS Installation Observation Gfu1Jo Jt.1NC:TION iil:'.l:l<:-17 103 WEST TOMICHI AVE, SUITE A 10 1 FOUNDERS PLACE, KNIT 102 GUNNISON, CO 8 1 230 PO Box 2 155 970.64 1 .5355 ASPEN, CO 8 16 1 1 970.641 .53513 FAX 970.925.6727 970.925.4157 FAX Gfu1Jo Jt.1NC:TION iil:'.l:l<:-17 2768 COMPASS DRIVE, SUITE 102 320 THIRD STREET GRAND JUNCTION, CO 81 505 MEEKER, CO 8 164 1 970.245.257 f 970.876.5 180 970.245.2871 FAX 970.876.4185 FAX Cy� SCHML ESER j GORDON J MEYER 'q� ENGINEERS)SURVEYORSS If there are questions, please call. Sincerely, SCHMUESER GORDON MEYER, INC. Brian Edwards, ROWP cc: Pitkin County Environmental Health 2010-335.0011L201011051Cliff House OWrS Installation Observation 4 o=mn f= nouN�m m�Oo=nm �$anm 77 oma"�� - e g - L 7� 6640 u "0o°z u.° m 1 m � b �O O PI. .- o- R O IF I w R a S ■min Cliff House Restaurant Aspen Skiing Company Onsite Wastewater System c'YT11 lk LiiFrHOUS esu;ran-• I^ SCHMUESER GORDON MEYER !+vV� E N 0 1 N E E R S S U R V E Y 0 R S Cliffhouse Restaurant Onsite WW System OPERATION & Maintenance Manual Operation and maintenance of the wastewater treatment system should only be performed by trained and certified personnel. ■ Educating Users of the System System users should be educated and reminded that an onsite wastewater system is different from public sewer service. There are daily considerations such as not putting plastic or other non - biodegradable material into the system that should be followed. Signs should be posted in common areas around the facility that educate users about the system and includes a list of materials not suited for disposal into a septic system such as cigarette butts, floss, bleach, feminine products, paint, etc. The sign should also state to contact the facility manager if you are unsure about what items can be deposited into the septic system. ■ General Information Water use should be monitored so toilets are not allowed to leak when seals malfunction. Fixtures should not be allowed to flow continuously to prevent water lines from freezing. Although the proposed system can accommodate variable flows, spreading water use over several hours and eliminating peak flows is recommended. Water softeners can not be used because the chemical and hydraulic loading from the backwash of the water softener may be detrimental to the septic system. If a water softener must be installed at a later date, a separate drywell would be constructed for the backwash waste. No landscaping or plastic will be allowed over the field, which would reduce performance of the field. The design of the septic system is based on the treatment of domestic sewage only. No industrial or hazardous wastes should be introduced into the system. The each of the proposed fields are designed to process an average daily flow rate of 1999 gallons per day (GPD) and a peak flow of 2999 GPD. To prevent the overloading of the system the elapsed time meters and counters for each of the system's pumps should be recorded daily to monitor flows. The flow meter located within the warehouse on the potable water tanks should also be recorded daily to verify the data. In the septic tanks, heavy solids settle to the bottom of the tank (sludge) and the lighter material (scum) floats to the top of the liquid contents. Facultative and anaerobic digestion converts some of the organic matter to gases. Microbes consume and digest the complex organic materials to soluble organic acids while strict anaerobes ferment the organic acids to gases (methane, carbon dioxide, etc.). ■ System Components The system includes a gravity sewer to a grease trap that then gravity flows to 2- 2,000 gallon septic tanks joined in sequence. From the septic tanks the effluent gravity fees to a 1,500 gallon clarifier/ dosing tank with dual, alternating pumps that deliver effluent to the septic fields. The control system for the dosing tank includes a four float system with controls panels for each dosing tank and pump. The float system is as follows: the low float turns the circuit on for the pumps, the second float turns the pump on, the third float turns the lag pump on, and the top float SCHMUESER I GORDON I MEYER !+vY� ENGINEERS ISU RVEYORS Cliffhouse Restaurant Onsite WW System OPERATION & Maintenance Manual is a high level alarm. The control panel for each dosing tank controls the alternating pumps and includes an elapsed time meter and counter for each pump. Any additions, exclusions and/or modifications to the systems should be brought to the attention of the design engineer and maintenance contractor. ■ Maintenance Requirements Record Keeping. A written diary should be maintained that describes all activities relating to the onsite wastewater systems. This information will be used for analysis and trouble shooting if problems should occur. In addition, use the form provided with this O&M Manual for ease of recording and record keeping. The daily readings from the elapsed time meters and counters at the septic system control panel and flow meter in the warehouse shall be recorded in the diary and transferred to the provided spreadsheet. The spreadsheet will be used to verify daily and thirty day -average flows for each septic system are meeting CDPHE and Pitkin County requirements. Each month the completed spreadsheet and diary logs should be sent to Pitkin County, the Engineer of Record and maintenance contractor. This information should be available at all times if a site visit is performed by the State or Pitkin County Health and the information is requested. It is imperative in record keeping that each systems daily flows do not exceed the 1999 GDP limits. If the average daily flows are greater than the above mentioned number then the system or systems are in violation of Pitkin County's Health Regulations and CDPHE requirements. Action should be taken immediately to correct the amount of flow going to the system or systems in violation. The maintenance contractor and design engineer should be contacted immediately and notified of the situation and corrective actions being taken. ■ Routine Maintenance General Maintenance. Maintenance should only be performed by a trained person or professional that has an understanding of the system and its operation. It is recommended that a trained maintenance contractor/operator be hired to inspect the system on a monthly basis to verify the system is operating properly and maintenance, as outlined in the document, is being followed. Routine Inspection. Routine maintenance should be performed daily to start, but can be tapered back when a baseline of data and proper system performance has been established. The maintenance contractor and the design engineer should agree to all future inspection/maintenance schedules. If it becomes apparent that the system routinely experiences the same problem/ problems, then the daily inspection schedule should be reinstated. Routine inspection should include the following, but not limited to, matters: • Verify the integrity of the electrical conduit is maintained and any consolidation is remediated immediately • Verify riser lids are secured and have only been accessed by trained personal • Verify cleanouts, monitoring wells, and riser lids are accessible • Verify grading is away from all riser lids, alternating distribution valves/housing, leach fields and monitoring wells SCHMUESER I GORDON I MEYER ENGINEERS I SURVEYORS 0 • Cliffhouse Restaurant Onsite WW System OPERATION & Maintenance Manual • Verify pumps are cycling properly • Verify proper maintenance is being performed • Verify record keeping is correct and being performed on a daily basis • Verify snow clearing is being performed to allow access to the systems components for maintenance and inspection • Verify the system is being operated in a manner consistent with this manual Monthly Observations. The grease trap basin should be observed every month and cleaned as necessary. The grease trap should also have positive drainage away from the risers and the tank, as water from the roof of the restaurant may contaminate the grease trap. Visual inspections will be made of the septic tank's liquid level. The liquid level should be no lower than the outlet invert. If liquid leaks out of the tank, the scum layer can drop to the level of the perimeter holes in the effluent filters and cause plugging of the screen. A watertight septic tank is important and any leakage must be corrected. An effluent filter should be placed in the septic tank and be checked every month and cleaned when necessary. There is an alarm for the system at the control panel of the dosing tank. If an alarm sounds it first should be determined whether the alarm is for the septic tank or the pumps. This can be determined at the control panel on site. Three -Month Observations. The sludge and scum accumulations in the septic tanks will be checked every three months. A record will be kept for the depths of both the scum and sludge in the tank. When the sludge depth reaches 36 -inches or when the scum layer reaches 18 -inches, the septic tank will be pumped, and the contents hauled to a treatment facility. Removal of Components for Maintenance. The ability to easily remove the BiotubeTM filter cartridge and pumps for maintenance is essential. The filter cartridge should be able to be removed without removing the pumps or discharge piping. To ensure that correct reinstallation has been achieved and to avoid future maintenance problems, use the removal process described below in steps a -i below. a. IMPORTANT! Before doing any work on either the wiring to the control float switches or pumps, set the circuit breakers in the panel to the "OFF" positions, and then switch off the power to the system at the service entrance panel. b. Completely close ball valves on the pump discharge assemblies (if necessary). C. Disconnect the PVC union located next to the ball valve. d. Remove the pump from the BiotubeTM pump vault, setting it aside on the fiberglass lid or a piece of plastic to protect it from mud or sand. The pump's electrical cord should not be disconnected. e. Remove the float assembly from the vault and lay it aside. f. Pull the BiotubeTM filter cartridge from the pump vault; the filter cartridge should be able to be removed separately without removing the pumps. g. Once filter and pump have been inspected and cleaned (if required), replace the pump filter, pump and floats. h. Open the ball valves completely. i. Replace access riser lid and make sure it is properly secured to the riser; an unlocked lid or open tank access is a safety hazard. SCHMUESER I GORDON I MEYER ENGINEERSISURVEYORS Cliffhouse Restaurant Onsite WW System OPERATION & Maintenance Manual Corrective Maintenance. An alarm is triggered when the liquid in the tank reaches a level that is higher or lower than it should be, or when a pump has failed. To silence the alarm, push the alarm light button on the control or alarm panel. The operator will determine whether the alarm is caused by high or low level conditions or pump failure. When the problem has been corrected (i.e. effluent level raised or lowered, depending on conditions), the alarm light on the panel will deactivate and the audible alarm will reset automatically. When responding to an alarm, first determine whether the alarm is caused by a high or low level condition, or pump failure. If it is due to pump failure (as indicated by a light on the recirculation panel), test each pump in manual and locate the failed pump. To replace the pump, see Removing and Replacing Inoperative Pumps. Remove the access riser lid and visually inspect the liquid level. If a high liquid level has caused the alarm, follow the procedures below. If the condition is caused by a low liquid level, see Low Liquid Level Alarm section of this manual. High Liquid Level Alarm. 1. When a high liquid level is present, first check the circuit breakers, switches, and fuses in the system control panel. If separate breakers in the main panel were used for the pumps and controls, also check those breakers. If a breaker is found to be tripped, reset the breaker and observe the operation for continuous tripping. If tripping does not recur, then likely the problem has been found or corrected itself. Test the automatic function of the system as shown in this manual to verify proper operation. 2. If, after checking the circuit breakers, fuses, and switches, the pump still does not operate, move the MOA switch to manual (MAN). If the pump engages, the problem is likely in the float system. If the motor contactor engages, but the pump doesn't start, go to step 6. Pump the tank down to a level just above the "Redundant OFF/Low level ALARM" float and return the MOA switch to the automatic (AUTO) position. Do not leave a pump in the MAN position unattended; if you do, the "Redundant-OFF/Low-level ALARM" float should turn off the pump and sound a low level alarm. However, in the event of a redundant -off failure, the pump can continue to run and draw solids to the screen and operate the pump without liquid, causing failure problems. 3. IMPORTANT! Before doing work on either the wiring to the level control floats and pump in the vault or in the pump control panel, set the circuit breakers in the panel to the "OFF" positions, then switch off the power to the system at the service entrance panel. 4. Isolate the float switches and check all floats are operating properly. If a float is found to be faulty, proceed to the section entitled Removing and Replacing Inoperative Floats. 5. Check pumps for discharge flow. Close the valve and disconnect the union in the discharge plumbing assembly and turn the union so that it is facing down. Engage the pump and visually inspect the approximate flow rate being discharged. If you are unsure of the discharge rate, fill a five -gallon bucket with the discharge and record the fill time. Check this value against the appropriate pump curve. If the flow rate is deficient, the pump intake may need to be cleaned. 6. If the pump operates in the proper flow range, check all downstream valves to ensure they are in the open position. 7. Check the panel to verify that the motor contacter engages. If the pump doesn't operate, then it is either a pump failure or a bad electrical connection. 8. Remove the access riser lid. If the splice box was submerged, or if there is a crack in the conduit, there may be water in the splice box. If this is the case, remove water from the splice box with a syringe or other appropriate method. Carefully check the splices to ensure that they are intact and remain watertight. If all splices are found to be watertight, replace splice box lid. SCHMUESER I GORDON I MEYER \W�� E N G 1 N E E R 5 I 5 U R V E Y O R 5 Cliffhouse Restaurant Onsite WW System OPERATION & Maintenance Manual In the control panel, carefully tug on each wire going to the splice box. Reconnect any wires that are loose. Reactivate and retest the system. 9. If the pump operates, but can't keep up with the flow, check the system for water tightness. A leaking tank can infiltrate enough water to overcome the pump. Also check for leaking fixtures in restrooms, though it is unlikely a leaky fixture could provide enough liquid to overcome the pump. Low Liquid Level Alarm. When a low liquid level is present, the source of the problem is likely one of three things: 1. The "Pumps -OFF" float has failed in the closed position. If the liquid level is at the "Redundant- OFF/Low-level ALARM", it is possible that the "Pumps OFF" float has failed with the circuit closed or there is a loose electrical connection. To check this, lift the "Redundant-OFF/Low- level ALARM" float. If the pump immediately engages, check the electrical connections for the "Pumps -OFF" float. If the connections are found to be adequate, check for proper operation of the float switch. Replace if faulty. If the pump doesn't engage when raising the "Redundant- OFF/Low-level ALARM" float, go to step 2. 2. The tank may be siphoning. Inspect the liquid level in the tank. If the liquid level is below the "Redundant-OFF/Low-level-ALARM" float, then likely the problem is either a leaky tank or siphoning. Siphoning typically occurs when the system is pumping downhill into the main line. When the pressure is low in the main line and a system operates, even after the pump shuts off, the system may continue to draw liquid from the tank with a siphon action. 3. If the hydraulics of the system do not allow for siphoning, then it is likely that the tank is leaking. Fill the tank to a normal operating level and return and inspect the tank at a later time. If the liquid level is below the normal operating level, the tank is leaking and needs to be repaired. Removing and Replacing Inoperative Floats. 1. Remove the float assembly from the vault. There is no reason to move the settings of the floats to remove and replace a float. Snap the float out of the holding collar. 2. Using a Phillips screwdriver, remove the stainless steel screws from the splice box lid, being careful not to drop the screws into the tank. If the splice box was submerged, or if there is a crack in the conduit, there may be water in the splice box. Call the Installer or maintenance contractor to repair the splice box. 3. Remove the inoperative float and replace it with a new one. Push the float cable through the watertight cord grip into the electrical splice box. Leave an adequate length of electrical cord coiled inside the riser to allow for easy removal of the float assembly. Do not remove the colored markers or the paper tags from the float cords, and do not try to thread the markers and tag through the cord grip. Tighten the cord grip by hand, not by tool, and then test the tightness of the cord grip by tugging on the cord. A cord is secure when the cord grip is tight enough to prevent slippage. An adequate length of cord should be left within the splice box to allow for easy removal for future disconnecting and re -splicing. 4. Splice the float wire to the wire from the control panel following the instructions provided in Appendix A. Attach the common wire with the other commons using the waterproof wire nut. It may be necessary to replace this wire nut with a new watertight wire nut. Always use watertight wire nuts or heat shrink splice kits for all connections! 5. Replace the float in the collar and return the assembly to the pump vault. 6. Reconnect power and test the unit per the instructions provided in the Operation section of this manual. SCHMUESER I GORDON I MEYER !`+.�/ ENGINCERSISURVEYORS Cliffhouse Restaurant Onsite WW System OPERATION & Maintenance Manual Removing and Replacing Inoperative Pumps. IMPORTANT! Before doing any work on either the wiring to the level control floats and pumps in the vault or in the pump control panel, place the circuit breakers in the panel to the "OFF" positions, then switch off the power to the system at the service entrance panel. 1. Close the ball valve on the discharge plumbing assembly, disconnect the union, and carefully remove the pump and attached plumbing from the tank. Disconnect the pump from the discharge plumbing assembly. 2. Using a Phillips screwdriver, remove the stainless steel screws from the splice box lid, being careful not to drop the screws into the tank. If the splice box was submerged, or if there is a crack in the conduit, there may be water in the splice box. Call the Installer or maintenance contractor to repair the splice box. 3. Remove the inoperative pump and replace it with a new one. Push the pump cable through the watertight cord grip into the electrical splice box. Tighten the cord grip by hand, not by tool, and then test the tightness of the cord grip by tugging on the cord. A cable is secure when the cord grip is tight enough to prevent slippage. An adequate length of cord should be left within the splice box to allow for easy removal for future disconnecting and re -splicing. 4. Splice the pump wires to the appropriate wires from the control panel. Always use watertight heat shrink splice kits for all connections! 5. Reattach the discharge plumbing assembly and carefully lower the pump into the 4 -inch diameter PVC flow inducer inside the screened pump vault. Be careful not to lower the pump by the cable or to pinch the cable when lowering it into the flow inducer. Reconnect the union and open the ball valve. 6. Reconnect power and test the unit per the instructions provided in the Operation section of this manual. ■ Trouble -Shooting The diagnostic chart at the end of this manual lists the most commonly reported symptoms and their possible causes. Read across the top of the chart to find the symptom and then read down to find the likely cause. For any symptom, the possible causes are numbered in the order most likely to occur. The cause identified by #1 should be investigated first, followed by 2, etc. Drain fields. The surface area around should be observed monthly for signs of surfacing such as lush vegetation growth or effluent ponding. Liquid levels within each field should be observed through the observation pipes and the levels recorded. Fencing should be placed around each drain field to keep grazing animals and wildlife from accessing the fields. Control Panels. The control panels for the dosing tank's pump and float assemblies should be enclosed to protect them from the elements and extreme conditions. Water Quality/Testing. In order for the drain fields to work and filter the influent correctly it is essential that water quality for the septic tanks be kept below the following limits: 300 mg/I BOD5, 250 mg/I TSS, 180 mg/I TKN, and 25 mg/I fats, oils, and greases. This caution is intended to educate the operator and provide him/her with an understanding of the design parameters of the system. If wastewater strengths in excess of these values are observed, corrective action will be taken to reduce the influent levels to an expectable point. SCHMUESER I GORDON I MEYER E N G I N E E R S I S U R V E Y 0 R S Cliff House Restaurant Aspen Skiing Company Onsite Wastewater System �� u `, A 1 �CLIFF}tpUS �es to ii ra1Lt SCHMUESER GORDON MEYER E N 0 1 N E E R S S U R V E Y O R S Pitkin County Environmental Health Department Contact Log Sheet Pitkin Country Environmental Health Department Contact Log Sheet Name: Parcel lD#: Address: Date : Person S 9ken To Comments /-Action to be.Taken _._ Initials Time Lw.L ? i. i� v 1 _A ,' r - I, Cb6�a u SQ Carla Ostberg From: Mark Kadnuck[makadnuc@smtpgate.dphe.state.co.us] Sent: Thursday, July 29, 2010 1:46 PM To: Carla Ostberg Subject: Re: Cliffhouse OWTS replacment If the max month average daily flow is less than 2000 gal/day, the system can be regulated by the county. Based on historical data, that appears to be the case for the Cliffhouse OWTS. Mark A. Kadnuck, P.E. CDPHE-WQCD 222 S. 6th Street, Rm 232 Grand Junction, CO 81501 ph: 970-248-7144 fax: 970-248-7198 email: mark.kadnuck(@state.co.us >>> "Carla Ostberg" <Carla Ostberg(@co.pitkin.co.us> 7/28/2010 10:30 AM Hi Brian and Mark, I have a few questions and wanted to be sure the design of the OWTS (Onsite Wastewater Treatment System - aka septic system) we are preparing to permit to replace the existing failed Cliffhouse system is agreeable to the Forest Service, as well as the Colorado Department of Public Health and Environment (CDPHE) Water Quality Control Division (WQCD). I have cc'd Scott Snelson from the Forest Service as well as Barbara Dallemand and Mark Kadnuck from CDPHE WQCD. Scott- In reviewing the application, the Forest Service approval letter dated lune 22, 2010 states that "...this project is approved if the repair only involves replacement of the existing infrastructure, and all work occurs within the original disturbance area...". The replacement system will serve the existing restaurant; however, the proposed systems have been cited in a "new" area as the area of the existing system (absorption area) has poor percolation rates. The proposed areas are in the existing ski runs of Teaser and Westward Ho. Could you please confirm that you are agreeable to the proposed location of new absorption areas on Westward Ho and Teaser? Brian - Given the placement of the proposed absorption areas in ski runs, there will be traffic from snow cats. Generally it is recommended there be no traffic over the absorption area. I understand the weight will be distributed in a way that should not cause damage to the field areas; however, I was hoping you could provide some specific engineering documentation that the cat traffic will not harm the system. LI Mark K. - The Aspen Skiing Company has provided historic water meter readings showing that water use averages around or less than 1000 gallons/day and only a few times in the last several years has water use exceeded 2000 gallons/day. The wells used to supply the Cliffhouse are referred to as "Lover's Lane" and this system is a non -community public water 1 0 system PWSID 249127. Could yvu confirm your agreement that this permit may be issued locally as the design criteria will not exceed 2000 gallons per day? Vark V. and Brian - The system design proposes alternating fields. An operation and maintenance agreement should be in place prior to final approval of the OWTS Construction Permit to be sure the system is operated as designed. This is the last step, after the inspection of the installation and after the as -built drawing has been received. Zian - The percolation test results were somewhat problematic in that 50% (3 of 6) of the tests resulted in a 0 mpi perc rate. The regulations state, "The absorption area percolation rate shall be the average rate of the percolation tests after the rate has stabilized in all of the percolation test holes." I would think there was no stabilization of the test if the results were 0. I also understand that a gradation was conducted using the United Soil Classification system. Methods recommended in our regulation are the USDA NRCS field evaluation procedure or ASTM Standard D2487-00, as you pointed out in our previous discussions. In lieu of secondary treatment, I want to assure the effluent is provided some opportunity to be treated by the soil and not simply hit a fractured Mancos Shale layer and travel down- gradient without proper treatment. I think the system, as designed, will provide good treatment and was conservatively designed with a percolation rate of 27mpi. I would simply like to confirm that the areas where a percolation rate of 0 was found will not be counterproductive to the design efforts that have been made. Alternatives would be to conduct additional perc tests, do a gradation at a depth below the absorption area to properly classify the soils in the area of the absorption fields, or provide secondary treatment to obtain a higher quality effluent before being discharged to the absorption areas. I would be happy to discuss these alternatives and any other ideas you may have to assure the effluent is being properly treated by the soils in the absorption area. If each of you could reply to the parts of this correspondence that I have highlighted, I will proceed with permitting. Thank you and if there are any questions or concerns, do not hesitate to call me. Carla Ostberg, MPH, REHS Environmental Health Manager Pitkin County Environmental Health 970-920-5438 Email secured by Check Point 2 a Carla Ostberg From: Jim Stark [jstark@fs.fed.us] Sent: Monday, August 02, 2010 1:47 PM To: Carla Ostberg Cc: Scott I Snelson Subject: Re: FW: Cliffhouse OWTS replacement Hey Carla - Scott and I actually did a site visit last week. While the new system does not stay within the old system's "footprint", we did confirm that the new proposal will remain out of any forested stands and occur on terrain previously graded/disturbed for the ski runs. As such, I believe that Scott is OK with the proposal. We would, however, want to make sure that the proposed system works ... ie, that your questions below are adequately addressed, especially your perc question to Brian. Please keep us in the loop .... Thanks much! Jim Stark / Aspen Ranger Station w-jstark@fs.fed.us 970-945-3314 h - stark@rof.net 970-925-1875 mobile 970-948-6447 "Carla Ostberg" <Carla.Ostberg@co.pitkin.co.us> 08/02/2010 01:18 PM Hi Jim, To <jstark@fs.fed.us> cc "Vogele, Mark R." <mvogele@aspensnowmass.com> Subject FW: Cliffhouse OWTS replacment Mark Vogele asked me to forward this email to you. I have exchanged voice mails with Scott, but we haven't been able to connect yet today. The first paragraph is a question for the Forest Service. If you or Scott could respond, that would allow me to get started on the permit. Thank you, Carla Ostberg, MPH, REHS Environmental Health Manager Pitkin County Environmental Health 970-920-5438 From: Carla Ostberg Sent: Wednesday, July 28, 2010 10:31 AM To: 'Brian Edwards'; 'Vogele, Mark R.' Cc: 'Barbara Dallemand'; 'mark.kadnuck@state.co.us'; 'ssnelson@fs.fed.us' Subject: Cliffhouse OWTS replacment Hi Brian and Mark, I have a few questions and wanted to be sure the design of the OWTS (Onsite Wastewater Treatment System — aka septic system) we are preparing to permit to replace the existing failed Cliffhouse system is agreeable to the Forest Service, as well as the Colorado Department of Public Health and Environment (CDPHE) Water Quality Control Division (WQCD). I have cc'd Scott Snelson from the Forest Service as well as Barbara Dallemand and Mark Kadnuck from CDPHE WQCD. Scott- In reviewing the application, the Forest Service approval letter dated June 22, 2010 states that "...this project is approved if the repair only involves replacement of t9existing infrastructure, and all work occurs within the original disturbance area...". The replacement system will serve the existing restaurant; however, the proposed systems have been cited in a "new" area as the area of the existing system (absorption area) has poor percolation rates. The proposed areas are in the existing ski runs of Teaser and Westward Ho. Could you please confirm that you are agreeable to the proposed location of new absorption areas on Westward Ho and Teaser? Brian - Given the placement of the proposed absorption areas in ski runs, there will be traffic from snow cats. Generally it is recommended there be no traffic over the absorption area. I understand the weight will be distributed in a way that should not cause damage to the field areas; however, I was hoping you could provide some specific engineering documentation that the cat traffic will not harm the system. Mark K. —The Aspen Skiing Company has provided historic water meter readings showing that water use averages around or less than 1000 gallons/day and only a few times in the last several years has water use exceeded 2000 gallons/day. The wells used to supply the Cliffhouse are referred to as "Lover's Lane" and this system is a non -community public water system PWSID 249127. Could you confirm your agreement that this permit may be issued locally as the design criteria will not exceed 2000 gallons per day? Mark V. and Brian —The system design proposes alternating fields. An operation and maintenance agreement should be in place prior to final approval of the OWTS Construction Permit to be sure the system is operated as designed. This is the last step, after the inspection of the installation and after the as -built drawing has been received. Brian —The percolation test results were somewhat problematic in that 50% (3 of 6) of the tests resulted in a 0 mpi perc rate. The regulations state, "The absorption area percolation rate shall be the average rate of the percolation tests after the rate has stabilized in all of the percolation test holes." I would think there was no stabilization of the test if the results were 0. 1 also understand that a gradation was conducted using the United Soil Classification system. Methods recommended in our regulation are the USDA NRCS field evaluation procedure or ASTM Standard D2487-00, as you pointed out in our previous discussions. In lieu of secondary treatment, I want to assure the effluent is provided some opportunity to be treated by the soil and not simply hit a fractured Mancos Shale layer and travel down- gradient without proper treatment. I think the system, as designed, will provide good treatment and was conservatively designed with a percolation rate of 27mpi. I would simply like to confirm that the areas where a percolation rate of 0 was found will not be counterproductive to the design efforts that have been made. Alternatives would be to conduct additional perc tests, do a gradation at a depth below the absorption area to properly classify the soils in the area of the absorption fields, or provide secondary treatment to obtain a higher quality effluent before being discharged to the absorption areas. I would be happy to discuss these alternatives and any other ideas you may have to assure the effluent is being properly treated by the soils in the absorption area. If each of you could reply to the parts of this correspondence that I have highlighted, I will proceed with permitting. Thank you and if there are any questions or concerns, do not hesitate to call me. Carla Ostberg, MPH, REHS Environmental Health Manager Pitkin County Environmental Health 970-920-5438 Email secured by Check Point Carla Ostberg From: Carla Ostberg Sent: Wednesday, July 28, 2010 10:31 AM To: 'Brian Edwards'; 'Vogele, Mark R.' Cc: 'Barbara Dallemand'; 'mark.kadnuck@state.co.us'-, 'ssnelson@fs.fed.us' Subject: Cliffhouse OWTS replacment Hi Brian and Mark, I have a few questions and wanted to be sure the design of the OWTS (Onsite Wastewater Treatment System — aka septic system) we are preparing to permit to replace the existing failed Cliffhouse system is agreeable to the Forest Service, as well as the Colorado Department of Public Health and Environment (CDPHE) Water Quality Control Division (WQCD). I have cc'd Scott Snelson from the Forest Service as well as Barbara Dallemand and Mark Kadnuck from CDPHE WQCD. Scott- In reviewing the application, the Forest Service approval letter dated June 22, 2010 states that "...this project is approved if the repair only involves replacement of the existing infrastructure, and all work occurs within the original disturbance area...". The replacement system will serve the existing restaurant; however, the proposed systems have been cited in a "new' area as the area of the existing system (absorption area) has poor percolation rates. The proposed areas are in the existing ski runs of Teaser and Westward Ho. Could you please confirm that you are agreeable to the proposed location of new absorption areas on Westward Ho and Teaser? Brian - Given the placement of the proposed absorption areas in ski runs, there will be traffic from snow cats. Generally it is recommended there be no traffic over the absorption area. I understand the weight will be distributed in a way that should not cause damage to the field areas; however, I was hoping you could provide some specific engineering documentation that the cat traffic will not harm the system. ` Mark K. —The Aspen Skiing Company has provided historic water meter readings showing that water use averages around or less than 1000 gallons/day and only a few times in the last several years has water use exceeded 2000 gallons/day. The wells used to supply the Cliffhouse are referred to as "Lover's Lane" and this system is a non- community public water system PWSID 249127. Could you confirm your agreement that this permit may be issued locally as the design criteria will not exceed 2000 gallons per day? Mark V. and Brian —The system design proposes alternating fields. An operation and maintenance agreement should be in place prior to final approval of the OWTS Construction Permit to be sure the system is operated as designed. This is the last step, after the inspection of the installation and after the as -built drawing has been received. Brian —The percolation test results were somewhat problematic in that 50% (3 of 6) of the tests resulted in a 0 mpi perc rate. The regulations state, "The absorption area percolation rate shall be the average rate of the percolation tests after the rate has stabilized in all of the percolation test holes." I would think there was no stabilization of the test if the results were 0. 1 also understand that a gradation was conducted using the United Soil Classification system. Methods recommended in our regulation are the USDA NRCS field evaluation procedure or ASTM Standard D2487-00, as you pointed out in our previous discussions. In lieu of secondary treatment, I want to assure the effluent is provided some opportunity to be treated by the soil and not simply hit a fractured Mancos Shale layer and travel down- gradient without proper treatment. I think the system, as designed, will provide good treatment and was conservatively designed with a percolation rate of 27mpi. I would simply like to confirm that the areas where a percolation rate of 0 was found will not be counterproductive to the design efforts that have been made. Alternatives would be to conduct additional perc tests, do a gradation at a depth below the absorption area to properly classify the soils in the area of the absorption fields, or provide secondary treatment to obtain a higher quality effluent before being discharged to the absorption areas. I s°% would be happy to discuss these alternatives and any other ideas you may have to assure the effluent is being properly treated by the soils in the absorption area. If each of you could reply to the parts of this correspondence that I have highlighted, I will proceed with permitting. Thank you and if there are any questions or concerns, do not hesitate to call me. Carla Ostberg, MPH, REHS Environmental Health Manager Pitkin County Environmental Health 970-920-5438 • ASPEN&INOWMASS ASPEN SKIING COMPANY Planning Department July 21, 2010 Ms. Carla Ostberg, MPH, REHS Environmental Health Program Supervisor Pitkin County Environmental Health 0405 Castle Creek Road, St. 10 Aspen, CO 81611 Re: Supplemental Information Repair Permit Application Cliff house Restaurant OWTS Buttermilk Ski Area Dear Carla: Attached is the additional information you requested from our meeting on Monday regarding the repair to the failed OWTS at Cliff house Restaurant on Buttermilk Ski Area. This information includes: ■ Revised permit application signed by David Corbin, Vice President of Aspen Skiing Company. ■ 3 years meter reading from the Lovers Lane well that supplies water (inflow) to the Cliffhouse Restaurant. We do not meter outflow from the building. ■ Copies of Well Permits for Buttermilk Ski Area ■ Internal email discussion of snowcat (track vehicle) versus wheeled vehicle traffic over fields. The Cliff house Restaurant was built in 1966 with a later addition added taking the total square footage to 12,149 square feet on two levels. The facility is composed of 275 seats with servery on the upper floor and kitchens, bathrooms, ski school meeting room, mechanical room and employee lockers on the lower floor. It is a "Pan -Abode" building built on a CMU block lower level. The facility is open from early December to early April each year during the ski season and closed to the public the remainder of the year. Please do not hesitate to contact me with any questions or additional information needs you have. Sincerely, 1*44-k 17111:_,�_ Mark Vogele Construction Manager Attachments Cc: File, Brian Edwards SGM Box 1248 (970) 923-8759 desk P.O. Bo Aspen, x 1 48 (970) 309-5019 cell (970) 923-9617 fax mvogele@aspensnowmass.com ASPEN( SNOWMASS ASPEN SKh G COMPANY Planning Department July 15, 2010 Ms. Carla Ostberg, MPH, REHS Environmental Health Program Supervisor Pitkin County Environmental Health 0405 Castle Creek Road, St. 10 Aspen, CO 81611 Re: Repair Permit Application Cliff house Restaurant OWTS Buttermilk Ski Area Dear Carla: Attached is the original Permit Application for the OWTS repair at the Cliff house Restaurant at Buttermilk Ski Area. Along with this I have included two stamped copies of the engineering report and design by Brian Edwards of Schmueser Gordon Meyer and a copy of the signed USDA Forest Service, White River National Forest 2010 Summer Construction Plan for Buttermilk Ski Area. As per this report, we are repairing the failed OWTS by replacing the existing infrastructure and all work will occur within originally disturbed areas. No work will occur in new undisturbed areas. We have walked the site with their representative Jim Stark to insure that all aspects of this repair are clearly understood and approved. A copy of this report and application has been submitted to their office for inclusion in their file. At this time we are pricing the repair work with several contractors from the County listing. Please do not hesitate to contact me with any questions or additional information needs you have. Sincerely, i Y Mark Vogele Construction Manager Enclosures Cc: File, Brian Edwards SGM Box 1248 (970) 923-8759 desk P.O. Bo Aspen, x 1 48 (970) 309-5019 cell (970) 923-9617 fax mvogele@aspensnowmass.com MEH/NR JNSITE WASTEWATER TREA . ENT SYSTEM (OWTS) CONSTRUCTION PERMIT 0405 Castle Creek Road, Suite 10 - Aspen, CO - 81611 Phone: 970.920.5070 Fax: 970.920.5077 Permit #: 10009 Parcel ID #: 2735-034-01-001 Permit Issued: ❑NEW ®REPAIR ❑REMODEL/ADDITION ❑TANK ONLY ❑FIELD ONLY []AMENDMENT Owner(s): Aspen Skiing Company c/o Kevin Hagerty, Mountain Manager Property Address: 0319 Buttermilk Summer Road (Cliffhouse Restaurant) Legal Description: Size of Lot: Size r'` 0 ;IA;n Acres Sn Ft Detached Accessory Unit: ❑YES ®NO Size of Accessory Unit: ,I UUIIUII 1y - Emergency Repair — timeline response to Notice of Violation Designed By: Not yet submitted Project #: _ Phone #: Mailing Address: Fax #: Email Address: Perc Rate: Profile Hole Depth: Minimum Tank Capacity: Dated: Depth to Groundwater or Bedrock: Minimum Absorption Area: Sq. Ft. This OWTS Construction Permit is approved on the condition of compliance with the engineer design as submitted with the application and the specifications cited above. Changes must be approved by this Department and the engineer prior to construction. A Notice of Violation was issued on May 4, 2010. The system may not be used in any capacity until repairs are completed or emergency use provisions have been approved by this department. An approximate timeline for repair has been established... • Start soil evaluation and perc tests — June 1, 2010 • Submit plans for review by Pitkin County & National Forest Service — June 18, 2010 • Receive comments and make any necessary changes — June 25, 2010 • Receive contractor pricing — July 9, 2010 • Obtain OWTS Permit — July 30, 2010 • Complete repair of the system — August 27, 2010 Please notify this department of any changes to this timeline. A completed application packet must be submitted to this department no later than June 18, 2010. This Permit must be kept on-site during installation. The engineer must do a final inspection of the installation and submit an "as -built" letter to this Department within 30 days of the final inspection, unless a longer period of time has been agreed upon, in writing. This Department must also be called for the final inspection with a minimum of 48 hours notice. ystem and physical features shall conform to the requirements of the Pitkin County OWTS Minimum horizontal distances between components of the s Regulation. ing for regular inspection, cleaning, and maintenance of the system by qualified personnel, in This Permit is conditioned upon the property owner(s) provid accordance with the manufacturer's recommendations and the requirements of the Pitkin County OWTS Regulation. THIS PERMIT IS EXPRESSLY CONDITIONED UPON COMPLIANCE WITH ALL REQUIREMENTS OF THE PITKIN COUNTY OWTS REGULATION, INCLUDING BUT NOT LIMITED TO THOSE CONDITIONS SPECIFIED ABOVE. --_A Dormiccinn is hAr,='1v Plans and specifications for the proposed Ow 15 nave peen revieweu cu iu ai u given to the property owner(s) to perform the work indicated in accordance with the Pitkin County OWTS Regulation. This Permit will expire 1 year from the date of issuance unless construction on the system has commenced. An "as -built" drawing must be submitted and approved by .EH/NR before final approval of the system will be issued. Issued By: Y�KU� Date: 5 �q! 1U Expires: Installer: License #: Reactivation Authorized by: Final Approval Issued By: Date: New Expiration Date: Fee FW D �IIr ONSITE WASTEWATER TREATMENT SYSTEM (OWTS) CONSTRUCTION PERMIT APPLICATION 0405 Castle Creek Road, Suite 10 Aspen, CO 81611 Phone: 970.920.5070 Fax: 970.920.5077 Parcel ID# (available from the Pitkin County Assessor's Office 970-920-5160 or at www pitkinassessor.orq): Purpose of Permit: 0 NEW n REPAIR DUE TO FAILURE ❑ REMODEL/ADDITION ❑ TANK ONLY ❑ FIELD ONLY Cost of System Repair or Remodel/Addition (approximate) Property Address: 0319 Buttermilk Summer Road Lot: Block: Filing Subdivision: Property Owner(s)`: Aspen Skiing Company Owner's Mailing Address P.O. Box 1248 Home Phone: 970-920-0770 'r'nntart information must be provided for the owner signing this application. Email Address: khagerty@aspensi City, State, Zip: Aspen, CO 81612 Business Phone: 970-923-1220 Primary Contact Person/Applicant (if not owner) Company: Victor Gerdin Aspen Skiing Company ContactiApplicant Mailing Address City, State, Zip Aspen, CO 81612 P.O. Box 1248 Cell Phone: Business Phone 970-379-2821 970-923-0555 Fax Number: Email Address: 970-923-9617 vgerdin@aspensnowmass.com Building Permit # (if applicable) Lot Size (in acres): NA Size of Building (square feet): Number of Potential Bedrooms: 12.148 2 (Caretaker Unit) Detached Accessory Unit? ❑YES X NO Size of Accessory Unit (square feet): Number of Potential Bedrooms In or Fixture List for the Accessory Unit: Water Source: Q PRIVATE WELL [:1 SURFACE WATER ❑SPRING COMMUNITY/PUBLIC WATER SYSTEM Name of Community/Public Water System (if applicable): Engineering Firm: Job Number: Phone Number: Fax Number: Schmeuser, Gordon, Meyer, Inc. 970.945.1004 Mailing Address: City, State, Zip'. 118 West Sixth Street, Suite 200 Glenwood Springs, CO 81601 PLEASE READ BEFORE SIGNING: I certify that the above information is complete and accurate and that I have provided complete and accurate information in all of the documents included in my application package. I acknowledge that EHINR may revoke any permit I am issued if my application is found to contain any inaccurate, false, or misleading information. I understand that no construction may be undertaken on an OWTS until an OWTS Construction Permit is issued. r Signature (Required): / ;ant Sig turDate FOR OFFICE USE ONLY V Received by EN/HR Staff Fee & Receipt #: Date 5/5110 ' rfLJMon pc , , _ Updated 10/7/08 Carla Ostberg From: Brian Edwards [Brian E@sgm-inc.com] Sent: Wednesday, August 04, 2010 9:42 AM To: Carla Ostberg Cc: Brian Edwards Subject: Revised perc tests for Skico Attachments: Perc TeaserField Revised.xls; Westward Ho Field Revised.xls What I did Carla was do new perc tests in the same area of the holes that were unacceptable. They have been added to the original form for you to reviewSee you at 1 pm or sooner if you like(call cell 309-7753). If acceptable I would like to pick up the permit to construct and I will deliver to Ski co as I have other issues to discuss with them this aft Let me know and thanks Brian Edwards ROM Energy Team Leader WaterMastewater Group Direct (970) 384-9035 Cellular (970) 309-7753 brianeCaD-sgm-inc.com SCHMUESER GORDON j MEYER E NaINEElt5 $uRVtYOFit i I 1 B WEST 6TH STREET, SUITE 200 GLENWOOD SPRINGS, CO 6 1601 970-945-1004 ; FAX: 970-945-5948 WWW.SGM-INC.COM 1 Church and Associates, Inc. TABLE 1 - Percolation Test Results Job Address Cliff House Westward Ho Field Job County, Colorado Pitkin Date: 8/3/2010 Feet Description 0-14 Organics 14-62 cobbles and boulders 62-96 fractured mancos shale TIME START END NO GROUNDWATER WAS ENCOUNTERED WITHIN EXCAVATION Job No. AVG. = 19 MPI DEPTH TIME START END CHANGE MPI RATE 1 20 20 20 3.50 8.50 9.75 8.50 9.75 10.50 5.00 1.25 0.75 4 16 27 27 H2O @ N/A 20 10.50 11.25 0.75 27 20 11.25 12.00 0.75 27 20 12.00 12.75 0.75 27 2 20 3.65 empty #VALUE! #VALUE! 0 H2O @ N/A 20 3.50 empty #VALUE! #VALUE! 20 0.00 #DIV/0! 20 0.00 #DIV/0! 20 0.00 #DIV/0! 20 0.00 #DIV/0! 3 20 20 20 4.75 6.50 8.25 6.50 8.25 9.75 1.75 1.75 1.50 11 11 13 27 H2O @ N/A 20 9.75 11.00 1.25 16 20 11.00 12.00 1.00 20 20 12.00 12.75 0.75 27 4 20 20 20 3.00 6.25 8.25 6.25 8.25 9.75 3.25 2.00 1.50 6 10 13 20 H2O @ N/A 20 9.75 11.00 1.25 16 20 11.00 12.00 1.00 20 20 12.00 13.00 1.00 20 Job No. AVG. = 19 MPI Church and Associates. Inc. TABLE 1 - Percolation Test Results Job Address Cliff House Westward Ho Field Job County, Colorado Pitkin Date: 8/3/2010 Feet Description 0-14 Organics 14-62 cobbles and boulders 62-96 fractured mancos shale TIME START END NO GROUNDWATER WAS ENCOUNTERED WITHIN EXCAVATION Job No. JAVG. = 19 MPI DEPTH TIME START END CHANGE MPI RATE 1 20 3.50 8.50 5.00 4 27 H2O @ N/A 20 20 8.50 9.75 9.75 10.50 1.25 0.75 16 27 20 10.50 11.25 0.75 27 20 11.25 12.00 0.75 27 20 12.00 12.75 0.75 27 2 20 20 20 3.65 3.50 empty empty #VALUE! #VALUE! 0.00 #VALUE! #VALUE! #DIV/0! 0 H2O @ N/A 20 0.00 #DIV/0! 20 0.00 #DIV/0! 20 0.00 #DIV/O! 3 20 4.75 6.50 1.75 11 27 H2O @ N/A 20 6.50 8.25 1.75 11 20 8.25 9.75 1.50 13 20 9.75 11.00 1.25 16 20 11.00 12.00 1.00 20 20 12.00 12.75 0.75 27 4 20 20 20 3.00 6.25 8.25 6.25 8.25 9.75 3.25 2.00 1.50 6 10 13 20 H2O @ N/A 20 9.75 11.00 1.25 16 20 11.00 12.00 1.00 20 20 12.00 13.00 1.00 20 Job No. JAVG. = 19 MPI i i SCHMUESER ! GORDON I MEYER ENGINEERS I SURVEYORS jf I i Mark Vogele Construction Manager Aspen Skiing Company P.O. Box 11248 �Asrn'PO,81612 i RE: Cliff House Onsite Wastewater System (OWS) Design Buttermilk Mountain - Pitkin County, Colorado Job # 2010-335.001 Mark, GLENWOOD SPRINGS I 1 8 WEST SIXTH STREET, SUITE 200 GLENWOOD SPRINGS, CO 8 1 601 970.945.1 004 970.945.5948 FAx As requested, Schmueser Gordon Meyer, Inc. (SGM) has prepared an Onsite Wastewater System (OWS) design for the Cliff house Restaurant. The OWS design was prepared for Individual Sewage Disposal System (ISDS) permit submittal to Pitkin County Environmental Health. SITE CONDITIONS The site is within the USFS lands in rural Pitkin County, Colorado. The site is along a gentle to moderately sloping ski run ridge area at the top of Buttermilk Mountain as indicated. The areas for the proposed drain fields are in existing disturbed ski runs known as Teaser and Westward Ho. The slopes at the proposed drainfield are approximately 20% to the northwest. As noted the proposed areas are covered by existing native grasses PROPOSED CONSTRUCTION There are to be two drain fields constructed at proposed at the subject site. There is to be a primary and alternate drain field constructed. It is proposed that the fields be rotated on a yearly basis by means of an approved diversion valve so as to extend the life of each field The OWS wastewater system is designed for 1999 gallons per day (GPD) as per Pitkin County Health Regulations. The flow from the OWS will be monitored at the pump discharge to confirm a 30 -day average is less than 2000 GPD and the peak day flow is less than 3000 GPD. The Aspen Skiing Company has provided historical water data to substantiate monthly/daily flows from the building. The information provided was calculated using flow meter records from the storage tanks from 1995 to 2009 and based upon the season from approximately Dec12 thru April 04 when the restaurant closes. Last years data as an example used 136,800 gallons over that period. When calculated over 112 days this showed a daily use GUNNISON ASPEN GRAND JUNCTION 103 WEST TOMICHI AVE, SUITE A 10 1 FOUNDERS PLACE, UNIT 102 2768 COMPASS DRIVE, SUITE 102 GUNNISON, CO 8 1 230 PO Box 21 55 GRAND JUNCTION, CO 8 1 505 970.641 .5355 ASPEN, CO 8161 1 970.245.2571 970.641 .5358 FAx 970.925.6727 970.245.2871 FAx 970.925.41 57 FAx rIlEEKEH 320 THIRD STREET MEEKER, CO 81 641 970.878.51 80 970.878.4181 FAx SCHMUESER I GORDON I MEYER E N O 1 N E E R 8 S U R V E Y O R 3 e- GPD which is well within the Pitkin County Health regulations of 1999 GPD. It is interesting to note that with the implementation of telemetry that water usage has decreased significantly. Because the restaurant is located on USFS land and projected skier visits there is no planned expansion of the facilities at this time. As a -result it is expected that usage will remain fairly constant subject to the skier visits. There is a planned renovation which will take place this summer to install waterless urinals and water conserving fixtures to maximize water flow reduction. This too will have a significant impact on wa�er reducing usage. SUBSURFACE CONDITIONS i Subsurface conditions have been investigated by excavating profile holes and percolation holes at four potential drain field areas as indicated, Proposed Field 1, and 2, were eliminated for various reasons. Subsurface conditions are relatively uniform. Subsurface conditions were investigated at four sites and consisted of approximately12 to 16 inches of topsoil, underlain to 8 feet by silty, clayey sand with cobbles and boulders, underlain by Mancos shale. At some of the base of test pits, backhoe refusal was approached for the light duty rubber tired backhoe. It was noted that the Mancos shale was fractured. No free water was encountered in the test pits at the time of excavation. No water was observed in the test pits the next day when percolation tests were performed. Three percolation tests were performed at each of the sites. The percolation tests were performed at depths of approximately 3 feet and in the proposed construction soil zone. The results of the percolation tests and location of percolation tests are presented. The average percolation rates ranged from 0 to 40 minutes per inch (MPI). A percolation rate of 27 MPI is recommended for the design of the drainfields. A geotechnical investigation by CTL/Thompson was performed at the site. The CTL/Thompson report encountered similar silty and clayey gravel underlain by Mancos shale. The lab testing determined that the samples classify as GM silty gravel using the Unified Soil Classification System (ASTM D2487). For the purposes of this design we recommend the field testing percolation results be used for the calculations. RECOMMENDATIONS The results of the subsurface investigations indicate a septic tank preceded by a grease trap and drain field OWS can be installed at the site. Considering the commercial nature of the wastewater, the following recommendations are provided: 1) an oversized septic tank capacity, 2) grease trap, 3) effluent filters, 4) pressure dosing of the drain field by pumps, 5) the drain field consist of chamber trenches. SANITARY OWS CA 1-0 S A' r 44 Septic Tank: A 3000 -gallon, two compartment concrete septic tank equipped with an effluent filter preceded by a 2000 gallon grease trap is recommended. The septic tank capacity is greater than the minimum size required and will allow for wastewater strength reduction. Due to the size of the wastewater flows and drainfield effluent it must be dosed with a preset dose volume. The timer will control discharge of effluent by the pumps over 24 hours. The effluent pump must be capable � j I SCHMUESER I GORDON MEYER E N G I N E E R S j s u l! v E Y o R s of pumping 30 -gallons per minute and 15 -feet of head. The pumping system is discussed below. If the septic tank is installed in traffic areas, the septic tank, access risers and lids should be installed with minimum AASHTA H-20 traffic loading ratings. Grease Trap: A 2000'gallon grease trap should be installed on the plumbing from the kitchen area prior to discharge into the septic tank. Access risers are to be installed to grade and sealed so as to prevent groundwater infiltration, contamination and provide for routine access and inspection as part of the maintenance program. 1 All sewer pipes beyond the septic tank are to be 4 -inch Schedule 40 PVC pipe. Cleanouts are to be installed every 100 feet. Drainfield: The drainfield of OWS 1 is to consist of five sections of field with three trenches per section, as presented. The OWS design is based on a 30 -day average sewage load of 1999 GPD, and a percolation rate of 27 MPI. The area required for a rock and gravel trench field would be 4365 ftz. With the use of infiltrator chambers and pressure dosing, a 50% reduction is allowed for a required area of 2182 ftz. This would be a minimum of 221 chambers. The proposed -- configuration is 225 chambers in 15 trenches 66 feet long at a maximum depth of 30 inches. The drainfield is to be dosed with a BiotubeTm duplex pumpvault located at the dosing tank as presented. Both Automatic Distributing Valves (ADV's) rotate dispersal to the five sections of each - drainfield. CONSTRUCTION M41- Movement over the drainfield area during construction should be kept to a minimum to avoid compaction of the soils. Once installed the drainfield areas should be protected from construction traffic or stockpiling of soils. Rubber tired equipment is to be kept out of the drainfield excavations and it is recommended that a track hoe be used The surface of the field should be seeded with a native seed mix as per USFS and Pitkin County guidelines after installation of the system. These mixes typically do not require irrigation and develop a growth 10 to 15 inches high. No utilities should be installed over the fields. All OWS components are to be installed in accordance with manufacture recommendations, and state, county, and local building and health code requirements. Commercial restaurant wastewater only, no (chemical, motor oil or hazardous waste) should be disposed of into the OWS. The proposed OWS should comply with Colorado ISDS Regulations. SEPTIC TANK EFFLUENT PUMPING SYSTEM The installation of an Orencoo Biotube° Pump System is depicted in the attached manufacturer detail. Pumping system substitutions that meet the following minimum specifications are acceptable. SCHMUESERIGORDON IM E N O 1 N E E R S I S U R V E Y O R 8 i Pumps --'tbe !pumps selected for the pump vault should have a minimum capacity of 30 gallons per minute (GPM) and a minimum Total Dynamic Head of 15.2 feet. A minimum power rating of 1/2 -Horsepower (208 -volt) is required for the pumps, Pumps shall be UL and CSA listed as an Effluent Pump .------ 4 -Two- OSI Model,-PF30 HH pumps are recommended. Electrical power requirements are presented on Figure 3. The design engineer should approve the effluent pumps selected for the OWS prior to installation. A manufacturer pump curve diagram is attached. Access Risers — Access risers that extend to final grade must be provided. The risers are to be watertight and attached to the septic tanks such that a watertight seal is provided. Risers should be rated for the appropriate load requirements. Discharge Assembly — The pump discharge assembly (OSI cold weather style) is to have a disconnect union accessible from the ground surface to allow pump replacement. The discharge assembly is to be plumbed to allow drainage between cycles to minimize freezing potential. Float Switch Assembly — The on/off and high water alarm floats are to be accessible for adjustment without removing the pumps or vault. Pump float switches should be set to discharge between 200 gallons per dose to the drainfield. The floats for the pump basin should be set to allow for the pump basin to discharge 50% of the volume of the dosing chamber to allow for surge capacity during peak flows. i Electrical Splice Box — The splice box shall be UL approved for wet locations. All wire splices are to be completed with UL listed waterproof splice connectors. It is recommended that an external splice box be used with grade access because of the caustic environment. Control and Alarms — Controls and alarms shall be listed per UI -508. Controls are to include a ' -- toggle switch for manual operation of the pumps; separate dedicated circuits for the pumps and the high water alarm; an audible and visual alarm; and an elapsed time meter and counter for system record keeping.. Panels are to be NEMA 4X rated. The control panel must be a MVP - DAX -208 -PT, RO, CS, EMT, ET. Location — The pump control panel is to be mounted within sight of the pump system. The panel is also to be located such that the alarm can be readily seen and heard (remote alarms to a location within the buildings can be provided). The panel is to be mounted at convenient heights to allow routine access and maintenance. INSTALLATION OBSERVATIONS The installation of OWS is to be observed by the Design Engineer. These observations include drainfield construction observations. At those times, subsurface conditions and scarifying will be reviewed. Other observations are prior to backfill. At those times, the septic tank and pumping system are to be installed with risers on the tanks, and inlet and outlet connections property bedded. The drainfield is to have an automatic distribution valve and perforated lateral pipes in place. A final observation will be required once the final electrical connection has been made prior to placing the OWS into service. 4 SCHMUESER , GORDON E N 6 1 N E E R 9 I S U R V E Y O R 9 Our -office should be called at 970-384-9035 to observe the installation of the OWS at least 24 hours in advance. These observations, any _repeat observations, OWS design revisions, staking of drainfield or additional site visit requirements are'not included with this design and will be at an additional unit rate fee per our fee schedule and contract arrangements. I OPERI►TION AND PREVENTATIVE MAINTENANCE SCHEDULE The goal of an operation and maintenance (O&M) schedule is to observe the operation, and perform minor maintenance to the onsite wastewater system to allow for proper, long term functioning of the system. An operation and maintenance schedule or contract with a private maintenance company should exist at all times. Septic Tanks: The scum and sludge accumulation in the septic tanks should be monitored yearly. —- (Once the scum or sludge thickness reaches 25% of the chamber depth, the entire chamber should ___tbe pumped. SGM anticipates a pumping frequency of 1 to 3 years at design flows. An alternative is a regular pumping frequency of every year. Tti�_.. _ Filter and Effluent Pumping System: The effluent filter at the septic tank discharge should be cleaned (hosed off) at the time of pumping or as needed. The effluent pumps should be checked semi-annually to ensure pumps are functioning properly. If the alarm sounds, the pumps and floats should be checked and/or serviced immediately. Drainfield: The surface area around the fields is to be observed monthly for signs of failure such as lush vegetation growth or effluent ponding. Liquid levels within each field are to be observed through the observation pipes, and levels recorded. Flow to each field is to be controlled through the automatic distribution valve (ADV). The ADV is to be insulated to prevent freezing. General: System users must realize an onsite wastewater system is different from public sewer service. There are daily considerations such as not putting plastic or other non -biodegradable material in the system. Water use should be monitored so toilets are not allowed to flow when seals malfunction. Allowing fixtures to flow continuously to prevent water lines from freezing is not acceptable. Although the proposed system can accommodate variable flows, spreading water use over several hours and eliminating peak flows is recommended. To illustrate the point, a malfunctioning toilet can consume in excess of 1000 GPD. An excess 1000 GPD to daily loading could flood and irreparably harm the OWS. SGM cautions against installation of a water softener. The chemical and hydraulic loading from the backwash of a water softener may be detrimental to the OWS and a separate drywell should be constructed for the backwash waste, if a softener is installed. No landscaping or plastic can be used over the field, which will reduce performance of the field. Chemically treated water from any source should not be introduced into the OWS. The design of the OWS is based on the treatment wpf domestic sewage only. No industrial or hazardous wastes should be introduced into the OWS. SCHMUESER I GORDON I MEYER ENGINEERS j SURVEYORS The proposed system design is based on an average daily flow rate of 1999 GPD. Greater flows may hydraulically or organically overload the system, causing premature failure. A water meter should be installed and recorded monthly to monitor flows. ITATIONS Our investigation, layout, design, and recommendations are based on data submitted. If conditions different from those described in this report are encountered, SGM should be called to observe the coditions. If proposed construction is changed, SGM should be notified to evaluate the effect of the changes on the wastewater system. All construction is to be in accordance with the ISDS regulations. Pipe type and size, burial requirements, and other specifications, which are not depicted in our report, are to conform to the requirements of the Pitkin County Health ISDS regulations. The installer of the system is to be approved by the Pitkin County Health Department, and is to have demonstrated knowledge of the ISDS regulations and requirements. Questions concerning this report are to be directed to Brian Edwards in office at 970-384-9035. RE Sincerely, d\ SCHMUESER GORDON MEYER, INC. 9'9 T ;- Brian Edwards, ROWP Dan Cokley P.E. 2 M OWTS DESIGN CALCULATIONS - for Pitkin 0 Owner's Name Oftou" Restaurant Parcel ID # House Size (sq. ft.) (75 gpd or 100 gpd) Number of Bedrooms in Main House Number of Offices, Libraries, Studies, Similar -sized Rooms in Main House Number of Bedrooms in Detached Caretaker unit Number of Offices, Studies, Similar -sized Rooms in Caretaker Unit (If the caretaker unit is ATTACHED, treat as if part of main h .) Average Daily Waste Flow 1999 State Review Req ' , no Perc Rate 2'1" Design Flow (Q) _ # potential bedrooms X 2 people/bedroom X gpd X 1.5 Q= 3000 Minimum tank capacity 3750 -gallons Absorption Area (=Q/5 X SQRT perc rate)(1.4 loadin A = 4,365 sq. ft. of absorption area required Absorption Area (=Q/5 X SQRT perc rate) WITH SECONDARY TREATMENT (no loading factor) A= 3,118 sq. ft. of absorption area required Abs. Area w/ loading factor (B25) Trench Bed Quick4 Trench Quick4 Bed Pipe and Gravel (-10%) 3928 no red. 4365 398 442 Dosing (-20%) 3492 (-20%) 3492 354 354 Chambers (-30%) 3055 (-10%) 3928 310 398 Max Allowable r 5M n (30%) a� 310 Secondary Treatment 1111 Abs Area w/ out loading factor (B28) Tren!!: Bed Pipe and Gravel (-10%) 2406 no red. 3118 284 316 Dosing (-20%) 2494 (-20%) 2494 253- 253 Chambers (-30%) 2182 (-10%) 2806 221 284 Max Allowable (-50%) 1559 (30%) 2182 158 221 260 SETBACK FROM WELL # of feet = 210 SETBACK FROM POND, STREAM OR IRRIGATION DITCH # of feet = 185 SETBACK FROM DRY GULCH # of feet = Schmueser Gordon Mever TABLE 1 - Percolation Test Results Job Address Cliffhouse Restaurant Westward Ho Field Job County, Colorado Pitkin County 6/25/2010 Feet Description 0-14 organics 14-62 cobbles and boulders 62-96 fractured mancos shale START END CHANGE NO GROUNDWATER WAS ENCOUNTERED WITHIN EXCAVATION Job No. I AVG. = 18 MPI 6MI DEPTH TIME START END CHANGE MPI RATE 1 20 3.50 8.50 5.00 4 27 H2O @ N/A 20 8.50 9.75 1.25 16 20 9.75 10.50 0.75 27 20 10.50 11.25 0.75 27 20 11.25 12.00 0.75 27 20 12.00 12.75 0.75 27 2 20 3.65 empty #VALUE! #VALUE! 0 H2O @ N/A 20 3.50 empty #VALUE! #VALUE! 20 0.00 #DIV/0! 20 0.00 #DIV/0! 20 0.00 #DIV/0! 20 0.00 #DIV/0! 3 20 20 20 4.75 6.50 8.25 6.50 8.25 9.75 1.75 1.75 1.50 11 11 13 27 H2O @ N/A 20 9.75 11.00 1.25 16 20 11.00 12.00 1.00 20 20 12.00 12.75 0.75 27 Job No. I AVG. = 18 MPI 6MI Schmueser Gordon Meyer TABLE 1 - Percolation Test Results Job Address Cliffhouse Restauant Teaser Field Job County, Colorado Pitkin County 6/25/2010 Feet Description 0-18 organics 18-70 silty clay w cobbles and boulders 70-96 mancos shale END CHANGE MPI NO GROUNDWATER WAS ENCOUNTERED WITHIN EXCAVATION Job No. AVG. = 13 MPI DEPTH TIME START END CHANGE MPI RATE 1 20 4.75 empty #VALUE! #VALUE! 0 H2O @ N/A 20 4.50 11.75 7.25 3 20 11.75 empty #VALUE! #VALUE! 20 0.00 #DIV/0! 20 0.00 #DIV/0! 20 0.00 #DIV/0! 2 20 3.75 7.50 3.75 5 40 H2O @ N/A 20 7.70 10.00 2.30 9 20 10.00 11.50 1.50 13 20 11.50 12.63 1.13 18 20 12.63 13.50 0.88 23 20 13.50 14.00 0.50 40 3 20 20 20 5.25 4.75 empty empty #VALUE! #VALUE! 0.00 #VALUE! #VALUE! #DIV/0! 0 H2O @ N/A 20 0.00 #DIV/0! 20 0.00 #DIV/0! 20 0.00 #DIV/0! Job No. AVG. = 13 MPI Pump Selection for a Pressurized System - Input Parameters Effluent Pumps PF30 Series 1/2hp to 1-1/2hp Orifice Size 1/8 inches Residual Head at Last Orifice 2.00 feet Orifice Spacing 3.0 feet Number of Laterals per Cell 15 Lateral Length 61.0 feet Lateral Line Size 1.25 inches Lateral Pipe Class/Schedule 40 Distributing Valve Model 6605 Manifold Length 18.0 feet Manifold Line Size 1.50 inches Manifold Pipe Class/Schedule 40 Lift to Manifold 0.0 feet Transport Length 315.0 feet Transport Line Size 1.50 inches Transport Pipe Class/Schedule 40 Discharge Assembly Size 1.50 inches Flow Meter None inches 'Add-on' Friction Losses 0.0 feet Calculations Effluent Pumps PF30 Series 1/2hp to 1-1/2hp Minimum Flow Rate per Orifice 0.27 gpm Number of Orifices per Zone 63 Total Actual Flow Rate 17.4 gpm Number of Lines per Zone 3 % Flow Differential 1 st and Last Orifice 2.7 % Lift to Manifold 0.0 feet Residual Head at Last Orifice 2.00 feet Head Loss in Laterals 0.1 feet Head Loss Through Distributing Valve 6.0 feet Head Loss in Manifold 0.1 feet Head Loss in Transport Pipe 6.1 feet Head Loss Through Discharge 0.9 feet Head Loss Through Flow Meter 0.0 feet 'Add-on' Friction Losses 0.0 feet Total Flow Rate 17.4 gpm TDH 15.2 feet 3( 25 1 20 w O 9 100 50 0 PF3015 0 0 Effluent Pumps PF30 Series 1/2hp to 1-1/2hp PF3010 PF3007 PF3005 0 10 20 30 40 Net Discharge, gpm Orenco Systems Incorporated 814AIRWAYAVENUE SUTHERLIN, OREGON 97419 • TOLL FREE: (800)348-9843 TELEPHONE: (541)459-4449 FACSIMILE: (541)459-2884 www.orenco.com • tIMlO12010,W CW IJH.. g� a MY p S ..• Tu. IS . 2010 2'I4wn PAW** Mx IJ .W 7010 TZJPM &l En 0l3 ODj)O-in i m Oz; 2 o� n �m� cm . 6 0OI hm 0 co, A--�c� WI'D ,o -N Ln 0 O OZ ,0)0030 NO cp- m AW � b 4 iq u � � ,>'•• �`'96�p `-•�"'-, iJ` _ _.��Y_`_ .,.� •-..,`~�, ~•~,~ ~~,,may~~ '~ , •.�\ t•,t`,,� \ � � / "C� � � Ing t L ' '•. ���fff G � .`_✓ t � jy \,..~ `` ...i _ � [+5 Y � � `\ ~ t 'K`,tk t t .t `,. .0 t `, O �t•`+� r ]/, ,`ice O // ,R M1 `l. ` Mme"• -`t � '/ ` �•..� .ori �``` y`•\..•�•• . M_ M M� g �• ° n 0 H � P a !1201012010—Su Mr AA -1N. V� rs Mdg so..¢' M. 15 M 2010 2'ldW. PWW.- V. 17 Ad 2010 2zNp *M1 C) T 0 Z m Ti Z z oO-K C: Z :1 D 0 � Z 0 3 m G,D3O—(n i m Vzo m? ��00?.�_ o �N� m 00—v=(n $ OAS 0co, Azmm �n b- o cM _ �NID�A� NGn000O cn 100)0 N , 3 14600 A nl O 4 4, x Iry so qla U) O� \ A 0 C USDA United States Forest White River Aspen-Sopris Ranger District Department of Service National PO Boz 309/620 Main St. Agriculture . Forest Carbondale, CO 81623 (970) 963-2266 Fax: (970) 963-1012 File Code: 2720 Date: June 22, 2010 Kevin Hagerty Mountain Manager termilk Ski Area ! P.O. Box 1248 Aspen, CO 81612 Dear Kevin: I have reviewed all of the proposed summer projects contained within your 2010 Summer Construction Plan for the Buttermilk Ski Area with Jim Stark. As discussed in more detail below, some projects will need some follow-up in the field to properly assess the merits and impacts of each. By this letter, I am approving projects that have been previously approved, as well as ones that do not warrant further review under the NEPA process due to the limited scope and intensity of their impacts to National Forest System land. Project specific details are as follow: Project #1 — Snowmelt Runoff Management: At the time of this letter, this project is a mute point. I will, however, look forward to reviewing your mountain drainage plan just recently completed and hopefully have the opportunity to discuss the plan with you in the field sometime this summer. Project #2 — Mowing/Brushing: This is considered normal ski traiLmaintenance, and as such, is approved. Project #3 — Noxious Weed Control: This too is considered normal maintenance for the ski area. For any treatment on National Forest System land, I would like for you to keep track of the number of acres treated, the species treated, and a rough description of the locations of treatment. At the end of the season, please send this information to Wayne Ives at the Sopris Ranger Station (wivesa,fs.fed.us) so that he can keep a record of your treatments. Project #4 — Removal of hazard trees, inspection of infected trees: The clean-up of dead and downed treeson existing ski trials, and/or in areas where there is an immediate threat to high occupancy areas or facilities, is approved. Removal of trees beyond these parameters will require further site review by members of my staff prior to an approval being given. Project #5,— Snowmaking upgrades and hydrant maintenance: All work occurring on existing lines will be considered normal maintenance and repair. No new snowmaking installations are. authorized under this letter of approval. r� s Caring for the Land and Serving People Printed on Recycled Paper � n Project #6 — General upkeep of buildings: All of the proposed activities are considered to be normal maintenance and upkeep, and are therefore approved as submitted. Project 97 — Regrade and revegetate Teaser Crossing bridge: This is considered to be a normal continuation of the project that was initiated last year, and is approved. Please follow all revegetation guidelines contained in the Buttermilk Mountain Resource Management Plan to have the best chance for successful vegetation growth. Project #8 — Winch Anchor Install: The anchors have been previously approved in prior summer construction plans. Accordingly, this project remains as being approved. Project #9 — Kid's Trail Maintenance: Continuing to remove potential hazard trees adjacent to kids ski trails is approved. In regards to the construction of a new tunnel structure in Wookie Woods, and creating a "clear separation between a kid's trail and snowmobile route", not enough detail is presented for me to make a decision at this time. Please schedule a site visit with Jim Stark and myself at your earliest convenience to review your proposal in the field. Project #10 — Summer road maintenance: Approved. Please reference the 2010 Drainage Management Plan for any guidance on placement of new water bars, rolling dips, etc. Project #11 — Mountain -wide revegetation: Approved. Normal summer operations. Reference the Buttermilk Resource Management Plan for revegetation guidance. Project #12 — Panda Hill Earthwork: Private land. No Forest Service approval necessary. Project #13 — Mountain -wide cleanup: Approved. Project #14 — Reposition Guest Services Building: Approved. Project #15 —Control Building Area Storage: More detailed information on this proposal, including a site visit, is needed prior to approval. Project #16 — Cliffhouse Septic System: This project is approved if the repair only involves replacement of the existing infrastructure, and all work occurs within the original disturbance area. Should the repair/installation involve impacts to new areas, a more detailed plan will be required to be submitted and reviewed prior to approval. Project #17 — Widen entrance to Uncle Chuck's Glade: Not enough information has been submitted for me to adequately assess the scope/impacts of this proposal. A more detailed proposal and site visit will be required prior to any prof ect approval. NEPA may be required if the scope of the project would result in any meaningful and measureable effects to NFS land. Project #18 — Install Magic Carpet: This project is not approved at this time. More discussion will be required, including all of the associated impacts that may be associated with the construction of the lift, as well as a detailed purpose and need for the lift. Sincerely, V'— SCOTT SNELSON District Ranger C \ USDA United States Forest White River Aspen-Sopris Ranger District Department of Service National PO Boz 309/620 Main St. Agriculture Forest Carbondale, CO 81623 (970)963-2266 Fax: (970) 963-1012 M File Code: 2720 Date: June 22, 2010 Kevin Hagerty Summer Area Manager Aspen Highlands P.O. Box 1248 Aspen, CO 81612 Dear Kevin: I have reviewed all of the proposed summer projects contained within your 2010 Summer Construction Plan for the Aspen Highlands Ski Area with Jim Stark. As discussed in more detail below, some projects will need some follow-up in the field to properly assess the merits and impacts of each, as well as the potential need for some level of NEPA analysis. Normal projects such as year-to-year maintenance, upkeep, and re -vegetation are approved by this letter. These include projects #1, #2, #4, #6, and #7. Discussion on the remaining projects is as follows: Project #2 — Noxious Weed Control: While approved above, I would like you to send any treatment activity, such as type of weeds treated, location, and treatment acreage, to Wayne Ives at our Carbondale. Office at the end of.the season. His e-mail is wives(a,fs.fed.us. Project #3 — Pine Beetle tree removal: I understand from Jim that this has occurred already this season. Should there be any additional brood trees identified, please get with Jim so that he can coordinate the efforts with our timber shop if necessary. Project #5 — Wind Damaged/Dead Fall Clean-up: This is approved only if the trees are in existing skiing terrain, and/or the trees will pose a threat to humans in high use areas and/or have the potential to damage facilities such as buildings or lifts. Any cutting outside of this scope will require site review from Jim or Aurora, and a subsequent approval from me prior to any, action being taken. Project #8 — Deep Temerity Trail Work: This project needs further discussion and review. It is unclear from the project description what exactly is being proposed. Please discuss with Jim in more detail so that he can better inform me of the scope of the project Project #9 — Gully clean-up: Approved, as this is clean-up associated with past years projects. Project 10 — Lower Oly Face tree removal: This project has not been previously reviewed or approved under any NEPA analysis, and therefore will not be approved at this time. A formal,: Caring for the Land and Serving People Printed on Recycled Paper M detailed proposal should be submitted if you wish to consider implementing this project in the future. If you should have any questions on any of the above, please do not hesitate to call with Jim Stark or myself to discuss. Sincerely, st'(S-� SCOTT SNELSON District Ranger v J I C GERDIN, VICTOR C From: GERDIN, VICTOR Sent: Sunday, June 20, 2010 5:07 PM To: Corbin, David; Vogele, Mark R.; 'briane@sgm-inc.corn' Subject: RE: new timeline? A snowcat weighs 15,000 pounds and that weight is spread out feet of tracks. Therefore the point load, even without snow, pick up truck. Victor � -----Original Message----- From: Corbin, David Sent: Sat 6/19/2010 3:18 PM To: Vogele, Mark R.; 'briane@sgm-inc.com' Cc: GERDIN, VICTOR Subject: RE: new timeline? Mark, You may want to get some data on snowcat and /or our Ops guys. My recollection is surface of their tracks is pretty modest figures, I've seen data before for bridge differences. David From: Vogele, Mark R. Sent: Wednesday, June 16, 2010 11:27 AM To: briane@sgm-inc.com Cc: Corbin, David Subject: FW: new timeline? Brian: over more than 200 square would be a fraction of even a 754'/s�- //__ weight bearing loads and distribution from Victor that the snowcat weight distributed over the compared to trucks. Though I don't remember the design purposes and was surprised at the This morning I called Carla about updating our schedule and to see if she has any concerns. No problem updated the permit timeline so you and I just need to recast it in a more realistic timeframe. Her only concern is snowcats driving over the field. I told her that Buttermilk has a policy to keep all equipment off the original field except for lighter weight grooming equipment and that we would implement a similar policy for this new one. What we will need is a statement in your report that says we cannot drive any trucks or heavy equipment over the field but that the lighter weight snowcats with cat tracks are fine. 1 Call me when you get a minW so we can update the schedule Once we have talked I will send it over to her for update. Mark Mark Vogele Construction Manager Aspen Skiing Company P.O. Box 1248 Aspen, CO 81612 970.923.8759 desk 970.309.5019 cell 970.923.9617 fax mvogele@aspensnowmass.com -----Original Message ----- From: Carla Ostberg[mailto:Carla.Ostberg@co.pitkin.co.us] Sent: Wednesday, June 16, 2010 10:45 AM To: Vogele, Mark R. Subject: new timeline? KDW11 Start soil evaluation and perc tests - June 1, 2010 Submit plans for review by Pitkin County & National Forest Service - June 18, Receive comments and make any necessary changes - June 25, 2010 Receive contractor pricing - July 9, 2010 Obtain OWTS Permit - July 30, 2010 Complete repair of the system - August 27, 2010 Please notify this department of any changes to this timeline. A completed application packet must be submitted to this department no later than June 18, 2010. 2 Carla Ostberg, MPH, REHS G Environmental Health Program Supervisor Pitkin County Environmental Health 970-920-5438 �J Carla Ostber From: Brian Edwards [Brian E@sgm-inc.com] Sent: Tuesday, August 03, 2010 10:22 AM To: Carla Ostberg Cc: Vogele, Mark R.; vgerdin@aspensnowmass.com; Corbin, David; Danny Stewart; Dan Cokley; Brian Edwards Subject: Snow cat load pressure The purpose of this email is to address your concern about the ground pressure exerted by the Aspen Skiing Company's snow cats driving over the new proposed septic fields on Buttermilk Mountain. SGM has researched the technical specifications of the equipment used. It was determined that the snow cats used will apply 1.16 psi (pounds per square inch) of pressure on the receiving surface. When calculating load dispersal and bridging properties through the snowpack there will be even less pressure exerted on the receiving ground surface. It is our opinion the snow cats will have very little impact on the absorption area which would impact the systems performance. I will be forwarding additional support documentation from the manufacturer and a thread of email correspondence to support this. Please let me know if there is anything else I can do to assist the permitting. Brian Edwards ROWP Energy Team Leader Water/Wastewater Group Direct (970) 384-9035 Cellular (970) 309-7753 briane(a--)sgm-inc.com SCHMUESER GORDON ! MEYER E 14 0 1 N[ E R 5 S U R V E Y O R S 1 1 8 WEST 6TH STREET, SUITE 200 GLENWOOD SPRINGS. CO 8 1601 970-945-1004 / FAX: 970-945-5948 WWW,SGM-INC.COM Email secured by Check Point Carla Ostber From: Brian Edwards [Brian E@sgm-inc.corn] Sent: Tuesday, August 03, 2010 10:24 AM To: Carla Ostberg Cc: Vogele, Mark R.; vgerdin@aspensnowmass.com; Corbin, David; Danny Stewart; Dan Cokley; Brian Edwards Subject: FW: Ground pressure, Attachments: BR350 English Dec 2006ok.pdf; PRI-090230-RZ3-NA-EN-Folder Bison-LOW.pdf; pic11478.jpg This is the email support letter from the manufacturer -----Original Message ----- From: Jim.Larson@prinoth.com [mailto:Jim.Larson@prinoth.com] Sent: Tuesday, August 03, 2010 9:24 AM To: Brian Edwards Cc: 7oe.Clark@prinoth.com Subject: Fw: Ground pressure, Brian, I am forwarding you this e-mail from our Director of North American Engineering, Martin Pelletier. In addition I am attaching the brochures for the BR -350 and Bison vehicles. In the BR -350 brochure you will find the published ground pressure data. The BR -350 was our previous version of vehicle that was operated by Aspen Ski Co. The current vehicle used by Aspen is the Bison. Our ground pressure specification for the Bison is now sensitive information, so you won't find it in the Bison brochure. The BR -350 and the Bison utilize the same chassis, track, implements, etc... The only significant difference is the cabin which is slightly heavier. Mr. Pelletier's e-mail reflects this. I hope this satisfies your needs. Regards, Jim Larson Service Manager Prinoth Rocky Mountain 970-242-7150 office 509-670-0395 cell (See attached file: BR350 English Dec 2006ok.pdf)(See attached file: PRI-090230-RZ3-NA-EN-Folder Bison-LOW.pdf) ----- Forwarded by Tim Larson/PrinothAmerica on 08/03/2010 08:36 AM ----- Martin Pelletier/Prinoth America Jim To 08/03/2010 08:19 Larson/PrinothAmerica@PrinothAmeric AM a cc Ground pressure, Hi Jim, See below the specifications you requested, Call me if you need more, Regards, Martin (Embedded image moved to file: pic11478.jpg) Martin Pelletier Ing. M.Sc.A. Research & Development PRINOTH LTD 1001, rue J. -A. -Bombardier Granby, Quebec Canada 323 1E9 Mobile 450.522.7178 Te1. 450.776.3600 ext: 3912 Telec. 450.776.3625 http://www.prinoth.com martin.pelletier(@prinoth.com A LEITNER TECHNOLOGIES Company 2 Subject Carla Ostberg From: Vogele, Mark R. [mvogele@aspensnowmass.coml Sent: Thursday, June 24, 2010 11:39 AM To: Carla Ostberg Cc: GERDIN, VICTOR; Corbett, Cathy M.; briane@sgm-inc.com Subject: RE: new timeline? Dear Carla: Here is the revised schedule based on additional investigation of areas of the mountain that will perc. • Submit a completed application packet — July 15, 2010 • Obtain County permit — July 30, 2010 • Complete repair of the system — September 17, 2010 Thanks for your patience and assistance in this process. I will be on vacation all next week and will be back in the office on Monday July 5th. In my absence please contact Victor Gerdin with any questions or information needs you may have Victor Gerdin (970) 923-0555 vgerdin(@aspensnowmass.com Thank you, Mark Mark Vogele Construction Manager Aspen Skiing Company P.O. Box 1248 Aspen, CO 81612 970.923.8759 desk 970.309.5019 cell 970.923.9617 fax mvogele(a)aspensnowmass. com -----Original Message ----- From: Carla Ostberg[maiIto:Carla.Ostberg@co.pitkin.co.us] Sent: Wednesday, June 16, 2010 10:45 AM To: Vogele, Mark R. Subject: new timeline? • Start soil evaluation and perc tests — June 1, 2010 • Submit plans for review by Pitkin County & National Forest Service — June 18, 2010 • Receive comments and make any necessary changes — June 25, 2010 • Receive contractor pricing — July 9, 2010 • Obtain OWTS Permit — July 30, 2010 • Complete repair of the system —August 27, 2010 Please notify this department of any changes to this timeline. A completed application packet must be submitted to this department no later than June 18, 2010. Carla Ostberg, MPH, REHS Environmental Health Program Supervisor Pitkin County Environmental Health 970-920-5438 [I Carla Ostberg M From: Vogele, Mark R. [mvogele@aspensnowmass.com] Sent: Monday, June 14, 2010 9:08 AM To: Carla Ostberg Cc: briane@sgm-inc.com; GERDIN, VICTOR; Corbin, David Subject: Buttermilk OWTS Schedule Good Morning Carla: Just a quick update to let you know that due to the weather, our schedule is put off for about a week. We have excavated half of our test holes and hope to do our percolation tests mid to late week. This means design will start first of next week. Please contact me if you have any questions or additional information needs. If not, I will keep you posted on our progress. Thanks you, Mark Mark Vogele Construction Manager Aspen Skiing Company P.O. Box 1248 Aspen, CO 81612 970.923.8759 desk 970.309.5019 cell 970.923.9617 fax myogele(&aspensnowmass com Aspen Skiing Company was recently named one of Outside Magazine's "Best Places to Work" for 2010. Join us today by visiting www aspensnowmass.comfobs Email secured by Check Point 1 EG 412445665 US ORIGIN '• ONLY) Delivery Attempt Day of Delivery Postage IPOZIPIle 1 Next 2nd ❑ 2nd Del. Day $ r Delivery Attempt S led Date of Delivery r L Return Receipt Fee 1. + Month � Day Scheduled Time of Delivery .__ Noon r❑3PM COD Fee -7 $ Insurance Fee Year '''```��� ❑ 2nd Day ❑ 3rd DayInt'I Total Postage &Fees 11? jA LRate Weight Alpha Country Code Acceptance Emp. Initial i /] ^{ FROM: (PLEASE PRINT) PHONE ( � / 0) 9 eo (.j)*tT ~ 5 I V 9 pdkl,-� (0tio Fov/ron/tVAicxl l icr t q0�5 ocrSI C, C'r-ep i( e,,,/, D P-15pr.-), (v R 10 11 rte" JGEXPRESS Customer Copy Md I L Label 11-B, March 2004 UNITED STATES POSTAL SERVICE® Post OfficeTo Addressee (POSTALDELIVERY Delivery Attempt Time ❑ AM Employee Signature Mo. Da ❑ PM Delivery Attempt Time ❑ AM Employee Signature Mo. Da ❑ PM Delivery Date Time ❑ AM Employee Signature Mo. Day ❑ PM U111STOMENoISE ONLY PAYMENT BY ACCOUNT WAIVER OF SIGNATURE (Domestic Mail Only) Express Mail Corporate Acct. No. Additional merchandise insurance is void R customer requests waiver of signature. I wish delivery to be madewithout obtaining signature Federal Agency Acct. No. or of addressee or addressee's agent (if delivery employee judges that article can be d I left in secure location) an Postal Service Acct. No. authorize that delivery employee's signature constitutes valid proof of delivery. ❑ Weekend � Holiday ❑ Mailer Signature TO: (PLEASE PRINT) PHONE ( 1 ! R5pf to SkIiiAji (vYvP0Y1UI C U kp v) , -,y H a `- r 1 130 X 12 q's ZIP s 4 (U.S. ADDRESSES ONLY. DO NOT USE FOR FOREIGN POSTAL CODES.) LJ� 0 El D E FOR INTERNATIONAL DESTINATIONS, WRITE COUNTRY NAME BELOW. _._.... .............. ____ryry Pitkin Connly___ May 4, 2010 BY OVERNIGHT MAIL Aspen Skiing Company, LLC c/o Kevin Hagerty, Buttermilk Mountain Manager PO Box 1248 Aspen, CO 81612 khagerty(@-aspensnowmass.com EAvironmeAlal Health _Natural Resources Re: Notice of Violation of Pitkin County Onsite Wastewater Treatment System (OWTS) Regulation — 319 Buttermilk Summer Road - Cliffhouse Restaurant - Buttermilk Mountain Ski Area Dear Mr. Hagerty, It is the understanding of this department that the Aspen Skiing Company, LLC (ASC) has retained the services of Brian Edwards with Schmusser Gordon Meyer to design a new OWTS for the Cliffhouse Restaurant, located at 319 Buttermilk Summer Road on Buttermilk Mountain Ski Area. Mr. Edwards has conducted recent site visits and his observations are that the existing OWTS serving the Cliffhouse Restaurant has failed and is surfacing. Mr. Edwards has consulted with this department to determine if an OWTS Construction Permit could be issued locally. After reviewing the conceptual design criteria for a proposed replacement OWTS, it appears to be feasible. Unfortunately, a failed system presents very real public health and environmental issues requiring prompt action by a property owner. Pursuant to Section 6.28.030(A)(6) of the Pitkin County Onsite Wastewater Treatment Regulation you are required to submit an application for an OWTS Construction Permit for a replacement system to this Department within 2 business days after receipt of this Notice of Violation. You can find the OWTS application and checklist at the following links. Application: http://www aspenpitkin com/Portals/0/docs/county/Com%20Dev/EHNR/OWT Constructi on Perm it%20Applicatio n. pd Checklist: http://www aspenpitkin com/Portals/0/docs/county/Com%20Dev/EHNR/OWT Constructi on permit appl checklist.pdf Due to the limited timeframe mandated for application submittal, it is likely that the items on the checklist will need to be submitted at a later date. It is only the application that is being requested at this time. Addressing this failure appears to be timely as the Cliffhouse Restaurant is currently closed for the season. This system may not be used until a repair can occur. If emergency or infrequent use is necessary, the tank serving the building may be pumped and plugged and used as a vault while these emergency repairs are conducted. Interim use should be discussed in conjunction with the application submittal. 0405 Castle Creek Road, Suite 10 Aspen, Colorado 81611 Phone: (970) 920-5070 Fax: (970) 920-5077 www.aspenpitkin.com/ehnr N kill County Environmental Health and Natural Resurees Please be advised that until this violation is addressed, no Pitkin County land use approval or permit will be issued for any property under the ownership or control of ASC. Additionally, failure to institute timely repair of this failed system may result in issuance of a cease and desist order and the assessment of monetary penalties for each day of violation. Please do not hesitate to call with any questions. Sincerely, oe- Carla Ostberg, MPH, REHS Pitkin County Environmental Health Program Supervisor 970-920-5438 cc: Mark Vogle, ASC Construction Manager (mvogle(o-)-aspensnowmass.com) David Corbin, ASC VP Planning and Development (dcorbin(a)-aspensnowmass. com) Victor Gerdin, ASC (vgerdin(a)-aspensnowmass.com) Brian Edwards, Schmusser Gordon Meyer (briane(a-)-sgm-inc.com) Jim Stark, US Forest Service (jstark(a�fs.fed.us) Mark Kadnuck, CDPHE Water Quality Control Division (mark. kad nuck(c)-state. co. us) 0405 Castle Creek Road, Suite 10 Aspen, Colorado 81611 Phone: (970) 920-5070 Fax: (970) 920-5077 www.aspenpitkin.com/ehnr Carla Ostberg From: Vogele, Mark R. [mvogele@aspensnowmass.com] Sent: Wednesday, May 12, 2010 1:16 PM To: Carla Ostberg Cc: GERDIN, VICTOR; Corbin, David Subject: RE: timeline Hi Carla: I'll call you to go over this in just a bit but I wanted to first get it down in email format June 1, 2010 Start Soils / Perc Test June 18, 2010 Submit Plans for Review to Pitkin County & National Forest Service June 25, 2010 Receive Comments and make any necessary changes July 9, 2010 Receive Contractor Pricing July 30, 2010 Have Permit in hand August 27, 2010 Complete repair of system Mark Mark Vogele Construction Manager Aspen Skiing Company P.O. Box 1248 Aspen, CO 81612 970.923.8759 desk 970.309.5019 cell 970.923.9617 fax mvo.q le(a)aspensnowmass.com -----Original Message ----- From: Carla Ostberg [mailto:Carla.Ostberg@co.pitkin.co.us] Sent: Tuesday, May 11, 2010 4:40 PM To: Vogele, Mark R. Subject: timeline Hi Mark, Can we talk tomorrow about a proposed timeline for Cliffhouse OWTS repairs? I'd like to draft a permit but would like to let you give me the timeline. Thanks, Carla Ostberg, MPH, REHS Environmental Health Program Supervisor Pitkin County Environmental Health 970-920-5438 Carla Ostberg From: Jim Stark Ustark@fs.fed.us] Sent: Tuesday, May 04, 2010 4:31 PM To: Carla Ostberg Cc: briane@sgm-inc.com; Corbin, David; Hagerty, Kevin J; mark.kadnuck@state.co.us; mvogle@aspensnowmass.com; Scott I Snelson Subject: RE: Cliffhouse Restaurant We are also in the loop on this. I have met with Brian to discuss this issue, and have briefly discussed with Victor. This is on NFS land, and as such, we will be directly involved with any solutions that are proposed. While Pitkin County may require that an application for a OWTS Construction Permit be submitted by May 6, it will merely be a paper exercise as far as the Forest Service is concerned, as we have not been able to look at the system's impacts to the ground sans snow, nor has a system been proposed that we can properly review and access the potential impacts to NFS land. I will suggest that a site visit be scheduled when the snow is melted so that we can all discuss on site to come up with a plan of action that best satisfies everyone's needs, requirements, etc. Victor and Kevin, I'll leave that up to you guys on when access to the top of the mountain is feasible. Thanks Jim Stark / Aspen Ranger Station w - Istark'Dfs.fed.us 970-945-3314 h - stark(o)rof.net 970-925-1875 mobile 970-948-6447 "GERDIN, VICTOR" <VGERDIN(ZDaspensnowmass.com> To "Carla Ostberg"<Carla.Ostberg(&co.pitkin.co.us> cc <mvogle(a)aspensnowmass.com>, "Corbin, David" <dcorbinna.aspensnowmass.com>, 05/04/2010 03:57 PM <briane(a)sgm-inc.com>, <istarkgfs.fed.us>, <mark.kadnuck(c)-state.co.us>, "Hagerty, Kevin X <KHagerty(a)aspensnowmass.com> Subject RE: Cliffhouse Restaurant Carla, Thanks for this notice and I'm sorry you had such a difficult time contacting Kevin. He had shoulder surgery last week and has been out for a few days. I'm glad to hear we can apply for an OWTS Construction Permit locally. I understand we are required to submit an OWTS Construction Permit application within 2 days of receiving the violation notice. We can comply with this requirement but understand we will not have a final repair design for some time. As soon as the snowmelts, we will conduct percolation tests that will facilitate a repair design for the system. In the meantime, the restaurant and its wastewater system will be shut down. As you suggest, we will pump the tank (when truck access is available), and plug the downstream line, to allow for emergency or intermittent use until repairs are completed. Please contact me at 923-0555 if you have any further questions. Thanks, Victor 0 From: Carla Ostberg Imailto:Carla.Ostberg@co.pitkin.co.us] Sent: Tuesday, May 04, 2010 2:35 PM To: Hagerty, Kevin J Cc: mvo_ Iq a@aspensnowmass.com; Corbin, David; GERDIN, ma rk. kad n uck@state.co. us Subject: Cliffhouse Restaurant Kevin, VICTOR; briane@sgm-inc.com; istark@fs.fed.us; I left both you and your assistant phone messages and am sorry I was unable to reach you. Please see the attached document. It has also been sent overnight US Mail. I have cc'd a number of other Aspen Skiing Company employees in hopes of reaching the right hands given that we are in the off-season. Please give me a call when you receive this and have a chance to review the letter. Thank you, Carla Ostberg, MPH, REHS Environmental Health Program Supervisor Pitkin County Environmental Health 970-920-5438 D o W N O CO N 00 N -J N (3) N ()1 N .A N co fJ N —> N N —� O CO —• co --• —, —a —a W —' N —' —' O CO00 I CA CT -P W N —� m —1 - ;i .p C3 m _ �� I �.rz Ol T' 5 , , —:t � -4-1> m r ci y m N :. 1 • y 1 N e� .t" q �►J -.a s ,x ��. ij � Ulm ' �, �T a � N 7� r m� C� 04 LY n N F m m C � T 4 ate.. ■ �. 1 O^: c CIIl / > ,1' V m m c`i y W (I, m K D, m a c o D r N -� G � � m T.� --� O cid W J Cn .A W N —� O CO co J W Cn m .p W N —�. CD p LJi �1 VF 43 i —• Ci i csy 6f3 ( Jz �T i U" U` \ �� % lrg c' D L)J W ZZ x O • 1 h w V 9 A � y VJ.H � � � w � r1s, LIP) M f 1 - cy- •.-.• .':. � :. ,� n •mow;. •� +"r_.'.: 'r'�p y,, ��j. �<jj O' i 1 `I +►J TO rn Ll ^= CEJC U'I Y. p -a CJ Cr Z m r - m +� C. �S . c_- Tl_ Ly, Cl U� ©( � G f$ 1 `w 1$ U, I �t, 1$Q, �` Ai 1-s--. _ `� D OEll c It Ai 14 W v W W N I V D O Q CO Oo N -J N W N Ui N A N W N N N N O —� CD —� b v m cn A W N O O co O Uti h co N —� z --y m is cp Qw W vg f Cr3 1 W l i� Qj c— C3 ^ fi tS ? -© Cst D m Olt LIJ CO 6 ) \Jo, _ �' Citi V`J A- j � � 9 ` � � P 41 —37 33 < m U K 'vi rV U > MI -ZI z "= lo Q _ Z 0 O` .e C C: retry cry Chm0 kAj O \� n C, r, �n m Ll A O N 00 (o OD —1 (Y) co CD (0 00 --j (3) ()1 4_1 -A" CD W co _r� Cl) — > 0 s cf- (S --o rn 1c, ID 10 U) _5 • -X, s. L71vi J, ,, Fp r- . Q" T p CIS cn m 97 m na Lrj "u, rl- 4 4k. (n 0 a VLrlA 011% -SM - _Z3 ma 1 Vwt I -4- olz cn Q0 --se, 4�r U, > m C, --4 z m 0 f� y' c- -e, q - m 14) --s:% mi m > --1 —Z m LY Z 14R, -D > q 90 Q ci- F -IT CA Zs Ll A O N 00 G1 --• WN O CO N OJ N 1 N 07 N CJ7 N .A N W N N N —� o co co 1 M cn .A CO N —� O (O co 1 m m -P W'Z ' rn z� 7 rn " -j > m =W m ro UZI C� ro r� C rn tJ rn z N � t r- i" �y jar °7f1 � ' rn -i . 4 >' rn � qr —' D I�T1 rn r O , m cin m lai (P rn i j b m � �o .. > r 7u !' U, C O r d .D G) ci, rn —' O c0 CXi �I m CJS -A W N C] p —� W J Cn Cn .A W N —e p cD W V CT A W N 114 ('� p m r G -� ca •• U c Cj+ n �s o <ri _ (A s cn cc p Z - Q cf` Q j , h Y� - m tt'+��� C .n - -td m goo, f < Z7 p cr CG 1 �. rn -n 41%1 M' gab v. (31 CIN�:� -� Xf v �' rD Ca l 171a'' AUX (si Cis ar, ui �rY c+� r U3 ^' 1� �, t� y va P s v\ � � � �'► tt 0 -moi In m r� ,�� tQ to IN �d WO, , D m Ic�Cf.) r� 1e3 1C' P 1G � m os a -- � o— crs csa . ' J, ks) f' q .� � c D O G) QQ m L�! IR g1 -Z-1 --� O (O OO --AW Ui N -A N co tV N N N O CfJ W C)) (Y] .A W +a N p (O co N -� D m J T- 9�� J (°� C` s tN �.• `� �; :J J J t "J4 cde; ti 1 k W _yJ C V • 14 v/ r ( kA i.TI t11 'J'+(�� cn v i I U'i r ti LF) — N O L4c D ®� I�� (?J QJ �J � JJ ?4 rj (T, NI' I CA cn '' 0�', - -r `la w -1V n q • C Iw " - ' i 3 - __ 1e _ Ttk Nf1iye Nom ' N f� �. CA ij y' � Cl)N � 10 G cp r O B f9. e� ICJ 6 h A i G i Do rn T'� D C C§ kA o', r m r c ,!b � u g3 ZDO pzr-„ ,,,c o� -r ..i �. z r $. -c;QJ IZN �. ... _ C C � I © � C"• 1� � � (j x C�'�" y' (�'�- t pt~4�i f� ? m �f V ai ''tt ✓� r�� �,,rA �"? 0�2 'J' ,,y� 9 �,yj `..� �l, '.5 � il`1 :,s t • - ,3.� ..� Z7 et �3 t , ($,�' a I� I � � IrT 9 x ®� W W N (O N OJ N N (T N Cn N N N N -� -� --� -�o,• -+ N -� -' O (D W J Ct W D O . d G C= c cr �-a c--.�• c c-� - 7-0 `NcJ mNTz�, t vrA Fl— uj Qj 9,j W 4 _jv C3 �,� c� V 1 �N Lnr I lid m vi OP co . yJ � �� i^\ 'V � �. rte- `%S � v • x/11 '� '„F � _C _ _ �t _ J jy V� O �s io i' tit ;u IN VlJ r-41 ]r,o- m Z; 0 T `fI U trp .� V1 J' (h Ut Vt Vg tli o Mf U) �5 C G Q C r N• rr1 ? ' `.s' ; �' + �? OQ J` , crZ -C .0 Opo Oma W }�� ?� -j D mZJ Z ` p 6 (. 1 0 o a lam, Q £ I-,& �:+ ~. _ `` can Co $� Qs OC m m Ff4r ZL -�, f" qi ' Y. n� e n � W W N O N (b N �l N m N Cn N .A N W N N N N O -� (D -� W --' -J -� M -• C)l -� A -.�, W -a N -� � 7"m �l (31 CT -P WO '•-I m L,4 1UR `:. - cgs s� ` `J'? I� r j Ut � 0, -' N 00, �— __ `•'� �` iu,R'�,1 � `� 1 � � :� 1 �J3 _ .�.� jam, "� � .� 3 Zt .til . !v N cn 1 C� rJ r 1C'J G �, i5Ci mi r+' 4-1 m< T (� r O, ^ i11 o c� "� U �" N c r 0( ?1 v`\` U� c�`irt� a C cam, cs,KA � � �► � ; �. �c� � � � �. ca�-�' ,.cam— ` C z M I, GO v:1 _7 ;� X, ,T ul gr D G rn m c~ 4� i c n Ca a < --VN ._ •p �.cn c vJ c IiiiNUN � o i i■� � i�.� 1�11��11 ���• 1 ��II� W --' W O N (D N Cb N —I IQ CT N Ch N .P N W fJ N N iV (D � !D � Co -. ^J � CY) _. CTI � A � GJ � N _, -> � pCO Oo �1 Cn .A W N -' � i O e- Z al C. W Q!5 LIT- m V6�� N �I� iii Vi '.` CO ri :s � e -, z Q'13 • 60 -.Q sT `� cr ,N m -1 ZZ010 _ c a �E m c7 r m N nr N -" m CO CO qp c�V D C • t cr � A "W�� ��' ., i� t`' •� 6 m r -n rn, _ � d its 1 � Cs 4G)O 1 00 03 D 4� > fl m N It -� O t0 w �I m (Ji .p W N O c0 W m cn .p co N —> O O \, / V ` 77 m -Zi �i -G IV v m r m 4 ca� �, 1 c v O a t• CD E �' r� 4A 13A �3 k/ 3J N ol 01 vr= N' LIA `g LyiD c c! � j ' 1 ? r m ' �'+� Q� �r cs� c. 3. c-, C _ -�i •S 6�. �. M C7 jr- ��i D m G) Ll41 rn F -1 C M D r ,� 171 -S� !7) q, -r JAW&, T W W O N C N W N --AD I N G) N LJi N A N C..; N N IV ,� O CO W -�! 0')U �i N ,a W Np �Ff-- CD co i -J (3) CT -h—I Z �I Lp 9� D m W W M cf) CA W W _ Lvj 1 ro o. 4 ` ' e 3 �, �� ,,,• tea,,, \ _ m Q jFlD- N (� UaY m n < Z r' �— kal pl, 'ten v �i <r, 1 .r `� vy ' -C U, `� `v rn- X N 'Rl LA dr, c 0 col rn r— tr1 > Z o m m TCf)z =n- Cf) Cl) D m m iJ lK' Cau .V. i7 -. Oco a �J• W m D cn r m OW W -'� W O N (O N W N -4 N Q7 N (r N A N W N tJ N -- N O --' (D ---t 00 �I O) -' Ch --• .A -• W .� N -� -i O (t� GYM 1 -Tc Q> CT -P W N -� -D-{ 0 "' Z m z S) no r 'K` 1 s �J ~ �v GG - m m jar ,`,.c' s J �` ' -r e ` `'rt X: ' m W w =, w w v,, '� -C vu m o U) r- olv Oil _E41, zz IYV .+. f y j `� ~� A4O CI i ' ' m z N +?Y �r N �. �� C O Ln V) t4 a .A Un 4,4VeGi 70 .t 4 _moi r O, V V e D m M UIN -i DO X t �11� 1 -� w �, . �I�� N. INII �� BUTTERMILK WELLS PERTINENT FACTS & DESCRIPTIONS BUTTERMILK Vii L #1 1. Serves Cliffhouse Restaurant 2. Adjudicated as case #W-1341, priority date of in Water Div. #5, State of Colorado.,, 3. Recorded on January 14, 1974 by Pitkjn',County Book 283, page 415. (Adjudication) 4 4. Well owned by ASC. BUTTERMILK WGh2,*.. JWVBRS LANE) : 1. Serves Cliffhouse Restaurant. 2. Adjudicated as case #W-1341, priority date of in Water Division #5, State of Colorado. 3. Recorded on January 14, 1974 by Pitkin County Book 283, page 416. (Adjudication) 4. Well owned by ASC. Nov. 1975 October 10, 1969, Recorder,- July ecorder, July 31, 1968, Recorder, BUTTERMILK WELL #3 (LITTLE TEASER): 1. Owned by Art Pfister. The agreement between Art Pfister and Buttermilk Mountain Skiing Corporation dated November 27,,1969 describing the rights of Buttermilk Mountain to use water from this well is recorded at Pitkin County, book 246, page 733, and is section 5 of the Amendment to Lease of November 27, 1969, which is recorded in book 246, pages 728 through 739, inclusive. 2. Adjudicated as case #W-1341, priority date of September 30, 1966, in Water Division #5, State of Colorado. Adjudicated by ASC. 3. Adjudication recorded by Pitkin County Recorder on January 14, 1974, book 283, page 417. BUTTERMILK WELL #4 ("CREPES WELL ---BUTTERMILK WEST") 1. Serves Crepes Restaurant. 2. Permit #019990-F, issued July 21, 1975; expiration date July 21, 1976. 3. Statement of Beneficial Use sent to Div. of Water Resources on October 15, 1975. 4. Adjudicated as application #W-2423, with APPROPRIATION date of June 20, 1974, in Water Division #5, State of Colorado. Signed by Water Judge on May 27, 1975. The appropriation of water is "awarded conditionally to the Buttermilk Well No. 4...., said use to be restricted to use between November first and April first of each year.... Application for a quadrennial finding of reasonable diligence shall be filed in March of 1979 and in March of every fourth calendar year thereafter so long as a claimant desires to maintain this conditional water right or until a determination has been made that this conditional water right has become an absolute water right by reason of the completion of the appropriation." 5 Adjudication recorded at Pitkin County on June 30, 1975, book 300, pages 309 and 310. 6. Well is owned by ASC. 7. On Dec. 15, 1978 Buttermilk's conditional right was made ABSOLUTE BUTTERMILK WELL #4 (cont'd,) "for COMMERCIAL PURPOSES...... with use restricted to use between November lst and April 1st of each year." 0 Nov. 1975 BUTTERMILK WELL #5 (TIEHACK WELL) 1. At various times in summer of 1975 this well was called Tiehack Well #1 and Buttermilk Well #3, but pending adjudication will be amended by Ken Sanford of Holland Hart to designate the well as Buttermilk Well #5 (11/19/75). (See attached memo to file of 11/19/75) 2. Permit #72216-A, issued October 31, 1973. 3. Statement of Beneficial Use sent to Div. of Water Resources on April 3, 1975. 4. Adjudication of Application for UndefgTound Water Right has been assigned a case number of W-2819 and`(is''pending the ruling of the referee in Water Division #5 as of November 21, 1975. 5. Well is owned by ASC. 11/19/75 DON RAYBURN DISCUSSED WELL NUMBERING , OWNERSHIP & ADJUDICATION PROBLEMS ON BM WELLS WITH KEN SANFORD OF HOLLAND & HART. 1. Sanford says that there is no problem caused by ASC's having adjudicated Buttermilk Well #3 (Little Teaser) even though the well is owned by Art Pfister. In fact, ASC would hav e priority in usage of water°tecause we have adjudicated it with a priority date of Sept. 30, 1966 (presumably before any adjudication by art Pfister). This was case #W-1341. 2. There is no legal problem with having two Buttermilk Wells #3, but for the sake of clarity, Sanford will amend the pending adjudication on the Tiehack well and number the well Buttermilk well #S. (Rayburn had previously requested that the Tiehack well be numbered Buttermilk Well #3 and later discovered that the Little Teaser well already had the designation of Buttermilk Well #3.) This is case #W-2819. 43 No Problem Cabin 196 44 Fort Frog Building (Video) 253 TOTAL SQUARE FEET: 63,045.50 8605 600 Source: ASC Property Services and Buttermilk Ski Area Mountain Manager I Utilities a. Cliffhouse: Water - Currently the source is Buttermilk Wells #1 and 2. ' 1+G in Lovers l.antyr Each are 150 feet deep with adjudicated flow of .044 cubic feet perr'second (each). fThe wells pump to a 6 j ion stora$e tanit. The water is chlorinated and then re -pumped through a 3,600 foot long pipeline to f0o'(i4 gallon storage tanks above the Cliffhouse,, Water is gravity fed to the Cliffhouse and there are canister filters in the restaurant. Water is supplied to the Cliffhouse through gravity fed water lines and filtered through canisters once it has reached the restaurant. Sewer - There is a 10,000 gallon septic tank and three seepage pits northwest of the building. The current approvals call for a water and sewer line to be constructed from the base to the Cliffhouse, which would tap into the city water and sewer system. As approved in the Environmental Assessment, a 10% increase in the overall footprint of the Cliffhouse will accompany these connections. b. Tiehack Water - Source is Buttermilk Well #4. This well is 75 feet deep with an adjudicated flow of .033 cubic feet per second. There is one 10,000 gallon fiberglass underground storage tank with chlorination. Sewer - The system, upgraded in 1986, has one 2,000 gallon septic tank and one 1,000 gallon septic tank, a dry well of 117 cubic feet and a leach field of 1,500 square feet. 16 order I— n iation, ress the r party :cond lged, id by CLAIM fins rhich ng , the ,)ns 's ingular n title, rst efit and has st t UK- - Y at 2:02 c ltgorded at 2:00 o'clock PM, Jan. 14.1974 l- L t U Recepjrion # 164861 Peggy E. Miklich, Recorder IN WATER CJ:':Z r 2 1O° 16486: Division Nu. • 3 MAY 2 IN THE DI;TRICT COURT IN AND FOR S TE OF CO aCq, WATER DIVISION NO. 5 , STATE OF COLORADO CASE NO. w-1341 Buttermilk._....------•--r`; c­";-_:. ----- - i JCWe o. IN THE MATTER OF THE ) APPLICATION FOR } WATER RIGHTS OF ASPEN SKIING CORPORATION } RULING OF THE REFEREE IN THE ROARING FO -1K RIVER OR ITS TRIBUTARIES ABSOLUTE DECREE FOR 0- ----6N-DER GROUND WATER RIGHTS TRIBUTARY } IN PITKIN COUNTY And the Referee having made the investigations required U'< by Article 21 of Chapter 148, C.R.S. 1963, as amended does hereby make the following ruling, to wit: This application was referred to the Water Referee of Water Division No. 5 on the 23rd day of January , 1973 - 1. Name of Applicant Aspen Skiing" Corporation Address Box 1243; Aspen, Colorar'o 2. The name of the structure is Buttermilk Well No. 1. 3. The Legal description of the structure is: The well is located in the SE4SWa of Section 10, T. 10 S., R. 85 47. of the 6th P.M. at a point whence the Northwest Corner of said SE-SW4 bears: N. 330301 td. 845 feet. 4. The depth of the well is 150 feet. 5. The date of initiation of appropriation is October 10, 1969. 6. The amount of water claimed is 0.044 cubic foot per second of time. 7. The use of the,water is domestic and commercial. 8. The State Engineer's number is 14284-F. 9. The Priority date is October 10, 1969. 10. The date of the application was June 30, 1972. It is the ruling of the Referee that the statements in the application are true and that the above described water right is approved and granted the indicated priority; subject, however, to J all earlier priority rights of others. It is accordingly ordered that this ruling shall become i effective upon filing'vith the Water Clerk, subject to Judicial review as provided by law. 4 Done at the City of Glenwood Springs, Colorado this & 1f�,�[, 197. ZZ day of no protest was filed in this natter. x G The foregoing ruling is confirmed Ji- ar►: approved, and is made the Judgment and Decree of this court. vi No protezt was The foregoing r ani approved, a Judgumt and De &Z'dRAOR eferee This application was referred to the Water Referee of t" i % L1 ftdadootcpoeck 01i,.Jan.14,1974 i I IN WATER C:� i.: p t # 1648b2 ASY E. Miklich, Rer_oxder IN WATL1. Division Nu. -i Division No. , 3 ??'� S F,DO, �OF 2 IM IN THE DISTRICT COURT IN AND FOR F 2 C (0 WATER DIVISION NO- 5TE O/c o he well is located STATE OF COLORADO ......-.... k .........".......-".---"----"-------.-- , 2 ... -------------------" -.- 2 CASE NO. w- 1341 or )cru'v le o. 1. Buttermilk Well No. 2 ' It is accordingly ordered that this ruling shall become IN THE MATTER OF THE } shall become APPLICATION FOR ) tober 10, 1969. WATER RIGHTS OF REFEREE ASPEN SKII`:G CO FO aATION ) RULING OF THE REFEREE per time IN THE RO.,,aI.11 r^'K DECREE FOR Iti RIVER OR ITS TRIBUTARIES } ABSOLUT% DECREE FOR � VD WATER RIGHTS } UNDER GRCUND WATER RIGHTS TRIBUTARY INVOLVED: )" 11%. W IN FITKIN COUNTY } as required C> And the Referee having made the investigations required 3oes hereby by Article 21 of Chapter 148, C.R.S. 1963, as amended does hereby }.. make the following ruling, to wit: eferee This application was referred to the Water Referee of 19773 ,—, . Water Division No. 5 on the 23rd day of Januar) , 197 3. — ation 1. Nage of Applicant Aspen Skiing Corporation Aorado olora Address Box 1248; Aspen, Colorado , 11 No. 1. 2. The name of the structure is Buttermilk '.Yell No. 2. he well is located 3. The Legal description of the structure is : The well is located R. 85 W. of the in the SE4S; of Section 10, T. 10 S., R. 85 W. of the 6th t Corner of said P.M. at a point whence the Northwest Corner 14 *• of said SE4S�1-'� It is accordingly ordered that this ruling shall become bears: N. 33030' W. 890 feet. shall become 4. The depth of the well is 150 feet. tober 10, 1969. 5. The date of in4 tiation of appropriation is July 1968. foot 6. The amount of water claimed is 0.044 cubic foot per per time second of time. mercial. 7. The use of the water is domestic and commercial. ZZ JV day of 197.3. 8. The State Engineer's number is none. 9. The Priority date is July 31, 1968. 1972. 10. The date of the application was June 30, 1972. atements in the It is the rating of the Referee that the statements in the application are true and that the above described water right is er right is approved and granted the indicated priority; subject, however, to however, to all earlier priority rights of others. It is accordingly ordered that this ruling shall become shall become effective upon filing with the Water Clerk, subject to Judicial review :o Judicial review as provided by lay. Dome at the City of Glenwood Springs, Colorado this this ZZ JV day of 197.3. , �+ No p+�otest eras filed in this mattar. i5 � The forcgaing ruling is confirmed++ Hamm AMUWroved, and is =W* the ai this' eft. ;. .. _.. .r�A __.a