Loading...
HomeMy WebLinkAboutpitkin.eh.273510101004 (2001)�MA Pitkin County Environmental Health Department Permit for an Individual Sewage Disposal System 0405 Castle Ck Rd, Aspen, Colorado 81611 Phone 970-920-5070 / FAX 970-920-5077 Replaces permit 20009 Permit # 01029 Parcel ID # 2735-101-01-004 Type of permit New(X ) Repair( ) Addition to House( ) Name of Owner Dr. & Mrs. Marc Epstein Street Address 300 W. Eagle Pines Rd Property legal description Lot 4 Eagle Pines Sub Size of lot 7.778 Total square footage of the house 13,319 Water source City of Aspen # of bedrooms in house 5 # of offices, lofts & similar sized rooms in house Caretaker unit Total square footage of the caretaker unit # of bedrooms in caretaker unit # of offices, lofts & similar sized rooms in caretaker unit Designed for what # rooms (list) SIX (6): 5 bedrooms plus 1 future bedroom or attached caretaker Permit information Designed by Dean Derosier, McLaughlin Water Engineers Mailing Address 111 P AABC, Aspen, CO 81611 Perc rate 30 Profile hole depth 8 ft Septic tank capacity 2,730 minimum Depth to groundwater or bedrock Absorption area 2,990 sq ft; 50% reduc= 1495 sq ft +8 ft r`nmmnnfa Septic permit approved per compliance with the engineer design and specifications dated May 9, 2001. Any changes must be approved by this department and the design engineer prior to them being made. Minimum horizontal distances between components of the system and physical features shall conform to the Pitkin County ISDS regulations. The design is for two 2,000 gallons tanks with effluent filters. There are two separate absorption fields with a total of 104 units. Installer must check with engineer to insure that flow is evenly divided into the different length trenches. This department does not endorse any brand of products. The engineer must do a final inspection of the installation and submit an as -built letter to this department. This department must also be called for an inspection with a minimum of 48 hours advanced notice. Permit approved by: ZG �►-t Date: Plans and specifications of the p posed individual sewage disposal system have been reviewed and are considered satisfactory. Permission is hereby granted to the owner or the agent to perform the work indicated in accordance with the Pitkin County ISDS Regulation in effect at the time of issue. This permit becomes invalid 6 months from the date that the permit was issued unless system construction has commenced or an extension has been approved in writing by the Department. As -built drawings must be included with this permit before the final approval will be issued. Installer: Final Inspection Approval: Date: /� ASi 'ITKIN ENVIRONMENTAL HEALTI �3ARTMENT APPLIGA 17ION FOR INDIVIDUAL SEWAGE DlarjuSAL SYSTEM 130 S. Galena St., Aspen Colorado 81611 ` Phone 970-920-5070/Fax 970-920-5074 Name of OWNER M,t VCS l C__E��re Owner's Mailing Address -V� i � T �� � 1 CZ 1!�-3 ((,;rp I Business Phone: Home Phone: q 70 22Y- 4 -1 44 - Primary Contact Person (all communication regarding this permit will go through this person) Name U Company j c -t Le tZ Contact Mailing Address 6E 1 % "ov/. Business Phone: qZ5 + 5 (j� Cell Phone: Fax: Parcel ID # (available from assessors orrice at 920-5160 or at www.aspen.com/assessorl) Street address of property Z7!3 i 6 0 i 0 ag Legal Description: Lot 4_5 ,Block Filing Subdivision 9,C�41& Size of lot: 7,77 acres. Type of proposed structure: 5 -FC Size of bldg. envelope: Total square feet of house �3 , J7 /9 -�,F # of bedrooms in house 15- # # of offices, lofts & similar sized rooms in house Caretaker Unit: Attached ( ) Detached ( ) Total area(sq. ft.) of caretaker unit 31,¢141 s_F. 1f of harlrnnmc in rAn-takPr unit # of offices, lofts and similar size rooms of caretaker unit Permit is for: New Home (y ) Repair due to failure ( ) Remodel/Addition ( ) Emergency use ( ) Water: Private well ( ) Spring ( ) Stream ( ) Community/Public Water System ( ) If community system: Name of system The fee for a ISDS application'lLfor a permit that takes 6 hours or less for the department to approve. If approval takes longer than 6 hours, a rate of $55 per hour will be charged. The maximum fee is $1000. The basic fee of $330 is due at the time of application. The remainder, if any, will be due in two stages: first, at the time of issuance of the ISDS permit; second, before final approval of the ISDS permit. Application for an individual sewage disposal system is hereby submitted. I hereby certify that the above information is true and accurate and that I have provided true and accurate information on locations of all existing and proposed wells, contour intervals, buildings, property lines, ditches, slopes, waterlines, springs, suction or irrigation lines, drinking water cisterns, drain tiles, irrigation ditches, lakes, water courses, streams, floodplains, dry gulches, and existing septic systems. I hereby certify that any such features not shown on attached site map are not present. Issuance of the permit does not imply the approval of any other permit required for construction pursuant to Pitkin County codes. No construction may be undertaken until all approvals and permits have been obtained. The Aspen/Pitkin Environmental Health Department, Pitkin County and employees of these agencies will be held harmless should the individual sewage disposal system fail or malfunction. The permit to construct is issued on information submitted by the applicant or his/her representatives. The owner assumes full responsibility in case of failure of the system. Signature of applicant 1 A71 Date Received by Receipt # Date ,7�> G:\eh\isds\isdsapp.doc r Pitkin County Environmental Health Department Contact Log Sheet Person Spoken To WIN Il� y v ��.• .L '� i iOtt /M, A WMA _ Imo: � . � - �- iA,._�_�_ Pitkin Erwironmental Health Departmer Contact Log Sheet , Name: : Parcel ID#: Address: -3 d Date S Person Spoken To Comments / Action to be Taken Initials Time IZ ?D L -Q e t McLAUGI-ILIN WA"(FR ENGINEERS, itch I I I P AADC ASPt:N, Cpl,0RAD0 ` 01 I 970-925-1920 97U-425-19741iix inwcasPeiI(amI'Ilei MEMORANDUM Date: DeCember 4_j,200_l_ To: Pitkin County Environmental Health, From: Dean Derosier; McLaughlin Water Engineers, Ltd. RE: Epstein Septic System - Recommendation of Final Approval AO -004.02 The system was designed and installed and placed into service in December of 2001. MWE and GDD inspected the installation of the system and found it was installed according to MWE's design and PCEH requirements. This letter is to serve as the acceptance letter for MWE and recommendation to Pitkin County for final acceptanCe Of the system. To my knowledge the system was installed according to MWE standards, the system layout was changed as per the attached drawing, which can be used as the asbuilts. The system consists of 2 - new 2,000 gallon tanks or 4,000 gallons total, two Serial distribution systems with 51 units in one and 53 units in the other, for a total of 104 units. All trenches were installed using a infiltrator gravelless chamber system. All setback limitations were meet. Please call/, is yoW ve j y questions. if -- , G. Den Derosier,vP. �. r•d bLGI-S26-0L6 9N3 H31UM NIIHonuioW dSb:20 IO b0 oaQ LETTER OF TRANSMITTAL McLaughlin Water Engineers, Ltd. I I P AABC Aspen, Colorado 81611 (970) 925-1920 FAX 925-1974 EMML - MWEASPEN®ROF.NET WE ARE SENDING YOU C Shop drawings 0 Copy of letter 0 Attached O Under separate cover via the following items: O Prints U Pians 0 Sampk:s a Specification QChangc Order 0 REMARKS A,-'/(- rj '95-2, ^- G /4' ` �' A l N 6 5 — /; VC, r T ,,�,,., , 5�.-► , �. 71r7 ,)PY TO SIGNED If enclosures are not as voted, kindly uo&y us at number above. 1-d *L61 -926 -OLS 9N3 831UM WI-Msn iow d2b:20 10 LZ daS McLaughlin Water c Project Titic Project No. �" 4 o y C,/ Date Subject Designed Paye �ysfG- �AyaH� 7i N'< p (� �' 'i f •� y d bL61-926-OL6 SN3 631UM N I -lHonw-low d2b s ZO TO LZ daS • r McLaughlin Water Engineers, Ltd. ...... -._ ��' .. ., ... �.. . fit. v. •- R:-Ah.i1`-n !- A..Y - U 1 :,. , i -f - • < ��..,. Project Title fr' f-' 71"F/r_� 7 '`� Project No. Subject � N i ` S Designed Page �O G %?uA.I auT 60 -0 G y V' .L1 ! s .� �f 5161114(. as' ped s b/.B T-Sz6-OLG io o a,pa(i 6.4 7-AAX 9G [, o esptr���lz- N`+5 CA OW3 a31UM WI-Monu3oW dSb:20 TO b0 oaG McLau h1in I Water ung nccrs Itd. Project Title Project No. Date Subject Designed Page �G /4 C /7 A S /9 l fka .. .... . ... .. P • d bLG T-S2G-OLG JN3 a31UM N I IHonuioW dzb s ZO 10 LZ daS Li 173 MWEMcLAUGHLIN WATER ENGINEERS, ltd. 111 P AABC ASPEN, COLORADO 81611 970-925-1920 970-925-1974 fax mweaspen@rof.net MEMORANDUM Date: May 9, 2001 To: Pitkin County Environmental Health; Marc Epstein From: Dean De:rosier; McLaughlin Water Engineers, Ltd. RE: Epstein Residence - Septic System Design Notes - Eagle Pines The following are my design notes for the new Epstein Residence Septic System design. 6 - Bedrooms - Approx. 13,000 Square Feet of living area 130 gallons per day per person - 30 minutes per inch pert rates (avg) - Perc Test by HP Geotech Attached Ground water 100+\- feet from surface Flow = Q = 6 bed rooms x 2 peo/br x 130 gal/day/per x 1.75 = 2,730 gallons per day. Tank_sizin - 6 - Bed Rooms requires 3,500 gallons of septic tanks; Q 1.25 The effluent. from the house will enter a 2,000 gallon tank for initial ent settling of solids. The tank will have a Bioerbtankswilled in flow downetheuhill to line of the tank. The effluent from this upper a second 2,000 gallon tank, also with a BioTube -- 400, away. This will provide 4,000 gallons of storage. The second tank is being placed near the the hill to provide a tank to stabilize the flows system at the bottom of after the steep run down from the upper tank, and to provide an additional location with better access for pumping and Biotube maintenance. Area of Septic field required = A A = (Q\5) x square roots of the pert rate (AVG) = 2,730/5 X SR(30) � A = 2,990 square feet = 193 Infiltrators Infiltrators 50% reduction for trenches = 1,495 SF Infiltrators = 15.5 square feet = 97 infiltrators System size is for 104 infiltrators to allow for even length oftrenches. he Two ty. separate disposal systems are being installed on t ottom with 15 units 60 tal System A will consist of 4 trenches units. System A is located on the east side of the disposal area. The trenches will be 10' apart stem and step down to match the 2°trenchesours fofh7 units lfor ae. ytotal Bof144 onsist of 2 trenches of 15 units a (go is infiltrators. System B is located in the west of system A�nd Each sated on the ridge and flat area and again trenches will be 10' apar will have a 4" Sch 40 PVC line into each row of infiltrators. Tees will be o rows. The layouts of the used to split the flow evenly into each set of tw systems are required to fit site conditions and meet all setbacks as shown on the attached drawing. A concrete splitter box will be installed just outside the lower tank to split the flow into each system evenly. The soil under the splitter box will be road base a minimum of 6" thick and compacted to 95%. The box will be set level and water tested to verify even distribution into each system. hown on the drawings. Tees will be installed on Tanks will be installed as s both the inffluent and effluent lines of the tank, set on the inside of the he tank a tank. Set top of line from tee within 1" of the roof of t er line of tee. Fill tank with water prior nd oYxo line downward 12" below cent backfill to check for leaks and leave water in tank for placing the system in service. Septic tanks will be a two -chambered tanks. Install a OSI 4" diameter Biotube in each new 2,000 gallon tank effluent line, inside the tank. The housing is to be 36" high with a cartridge length of 28", using SDR 35 PVC piping per Pitkin County ISDS requirements. Piping from the home to the tanks will be 4" SDR 35 PVC laid at a minimum of 1%. Insulate lines with less than 5 -foot of cover or in uninsulated crawl spaces. Maximum bend angle is 45 degrees. All piping, including the manifold lines, 4" PVC and, others are to be bedded in a minimum of 2" under and 6" over of 3/4" screened rock. The 104 units will be installed in a trench configuration as laid out to fit not be installed at the site, setbacks, and other restrictions. Trenches can one elevation, several terraced levels may be required to meet contours, individual trenches will be installed to within 1" of level. Other chances may be required to meet contours and site conditions with maximum of 6' of cover over the units, and a engineers' approval. Provide a max minimum of 2'. Return the slope of the hillside to preconstruction contours. Adjustments to fit site contourioandnArchitectexisting conditions domay Elevationsofthetank be made per approval of the eng'neer . installation and and trenches will be finalized in thefield brloretonfinal racceptance. System operation will be approved by the engineers p must meet all PCEH and MWE standards. No trees or irrigation systems will be installed on top of the septic disposal d shrubs that do not require watering may be planted field. Native grasses an over the top of the field. Maintain minimum setback backs from property lines and other spt3�aG$, as note ti d on the drawing to minimize disturbance and , xif•,ual blocking with natural vegetation. maintain;, �.,,. �,. G. De erri"s re's. gdd\( te:inn FROM : 1 CC-EPSTE I N Res. FAX N0. G99bw:h October 31, 2000 Marc and Nancy Epsteia 205 North 6th Street Asj=, Colorado 81611 970 544 0594 Apr. 10 2001 02:23PM P2 Cr.aca t'rWeCth'pawlak Geowbnical. tw- SM Cama Read IS4 Glenwood spriKm Colorado 81601 P'ho(W 970.%9-7488 fax: 970.915.8454 bPVeu ®hPBe*Wb—M Job No. 198 288 Sul)jeot: Additional Percolation Testing, Proposed Septic Disposal Sy3tem, Lot 4, Eagle Pines Subdivision, Pitkin County, Colorado. Dear Mr. and Mrs, Epstein: Ar rNuested by Marc $alter with Iglebart Constna:tion. a representative of Hepworth- Pawlak Geotechnical, Inc. conducted additional percolation testing at the subject site to evaluate the feasibility of an infiltration septic disposal system. The results of our work are pry in this report. We previously conducted a subeoil study for the proposed residence and perdolation testing for the leach field and presented our findings in reports dated iwe 3, 1998 and Decer;bt_r 21, 1999, Job No. 198 288. Additional percolation tesfing was conducted in the � of the Nordic Trail and presented in a report dated August 2. 2000, lob No. 198 288. A profile pit and three shallow backhoe pits had been excavated is two are" at the locations shown on Fig. I. Percolation test holes were hand dug in the bottom of the backhoe pits. The test holes were soaked one day prior to testing. The soils exposed in profile Pit 4 consisted of about 2 feet of topsoil overlying stiff clay and gravel to the proffie pit depth of 852 feet. The soils exposed in ProQ,e Pit 5 consisted of about 1 foot of topsoil, .1 foot of clayey sand with gravel and I S6 fleet of topsoil overlying relatively dense 4ayey sand and gravel with occasional cobbles to the profrle pit depth of 81A feet. Groundwater was not observed in the profile pits and the soils were slightly moist to moist. Percolation teals were performed ou October 27, 2000 by a representative of Hepworth- Pawlak Geotechnical. Inc. The percolation test results are presented on Table I. The percolation Lost results in area 4 indicate an lnfiltr 600 rate of between about 18 and 60 minutes per inch with en average *f-46srunutee per inch- The festrr rate of P-11 wee due to the looser matrix of the soil. The percolation test results in area S indicate an infiltration rate of 30 minutes per inch for P-14 and P-15. Test hole P-13 had 5% imba of water from s Oepreviom day and no percolation rate. Based on the FROM : ICC-EPSTEIN Res. FAX NO. : 970 544 0594 Mar. 09 2001 e8:43AM P2 Marc and Nancy Epstein October 31, 21)0(1 Page 2 subsurftce mcd1dom observed and the variable percolation test results, we rCCOWnmd a civil cagiam by eWgcd tO design the septic disposal sysieftL If them are auy questions or if we may be of fi3rtber assistance, please let us know. siv=ely. HBpWORTH - PAWj4N&5@Wft , _WCAL, INC. jordy Z. A i tea. Rev. by: NAI- JZA/kSW attachments ;!ion - AttDL;..NX)L-.Bak19 14-P GEOTECW I FPOM :]CC-EPSTEIN Res. FAX N0. : 970 544 0594 Mar_ 09 2001 08:43AM P3 I_,,. ALL- IIVLL _VI._ ..I!.J'.2 I }1 L'. J 1 - APPROMAIX V •r ar LOT 3 A Ma I ic P 1!6PRaDFi13 / P '!Z 11, PFT 4 PFF 5 LOT 4 rff� .ra. � RT 3�► IRAL P-6 A ,PROFILE BaVW 2 Aso f wY 2 P-2 ,& %* Al AJ /P-3 LEGIM A pDana+AL PEIM AIM IES1 EM' E PMIES W:VE • WFOWIS DMLUD FOR SUBSCIL S WY 6/3/" Lot 5 ll }EpWd�EN - PAILM LOCATION OF PERCo"moN imy HOLES E'�g. 198 291 GEOTECHNICAL, ING FROM : ]CC-EPSTEIN Res. �r FAX NO. : 970 544 0594 Mar. 09 2001 08:44AM P5 : l'P!�1 LroSCa • ,De.—t -__ "t, u - HEPWORTH-PAWLAK GEOTECHNICAL, INC. TABLE I PERCOLATION TEST RESULTS JOB NO. 198 288 Pam 7 of 2 HOLE NO. HOLE DEPTH S1tWWS? L NGM OF MITMAL (MINI WATER DEPTH AT $TMr OF ■ 71MAL gUC)1E6I WATER OEM AT EIS OF WW"AL 1 DROP IN WATO LEVEL amem) AVERN E PERCOWTgM RATE (WXANCH) P-70 48 1s MOos. added 6 D4 Y► so 4X 4% K 4 3% 1f' 3 v 3% X 3A 214 K a a % 4 iG 414 yi P-111 So 16 wear added 5 3 YA1 SS 18 3Yi 2V& 'X 7 A 6 X 1 e x y 5A 4% rA 4% 4 �G q a l 8 2 IL X P-12 so is water added 4% 4% x L OR 4 K 4 Y. 4 31 'k 3 y 3 I x' 316 3 Y` 3 2: x 5 • is X 4x 41 Noce: Percolation test holes were hand dug in the bottom of backhoe pita and soaked on October 218, 2000. percolation tests were conducted on October 27, 2000. The average percolation rates were based on the last three readings of each lost- FROM : ICC-EPSTEIN Res. FAX NO. : 970 544 0594 Mar. 09 2001 08:44AM P4 .. . r. ! i 1 I F'— . -R'T C.;i lam. i � I � r. L .1 . .1 1 . - 'I •'' : 13 .. "I-• HEPWORTH-PAWLAK GEOTECHNICAL, INC. TABLE I PERCOLATION TEST RESULTS JOB NO. 198 288 . Peae 2 of 2 i101r lVGG. HOLE D6PTM t +Es1 t EIiaTH OF RaERVAL (Mal: WATER DEPTH AT STMT of WTVWAL MiIClIE6 WATW DEPT" AT 00 OF WT1iWAt DMP IN WAWR (Wim! AVERAGE PERGALAT30N PATE (AIgP.lalCtl! P-13 so t5 S% 6 3S o did eat Pate SK sx a 8 6 3G 0 6% 636 0 51E 0 694 6'A 0 6 % 5 3E 6Y, aK 0 P-14 53 15 wew added S Z 30 6 4 7 4 3% K 3 >5 g 15 9 2 34 Z 2 R 5 4 sh Yb 4 3S 4 '4 P-15 90 15 8 Xe 6 V4 __. _ B iL 5 14 5 4% Y, 4K 4 4 3 Y+ K 3% $ Y' s x Nene: Percolation test holes were hand dug in the bottom of backhoe pits and soaked on October 26, 2000. Percolation tests were conducted on October 27, 2000. The average Percolation rates were based on the last three readings of each test. P-17 appeared to be more clayey than other percolation taste- The water in P-13 was left from the wetting on `_; October 26. IeUeivea: :y/ is/ul 10:29AM; 03-Oe-zool i w 5 From -GRAND JUN, .jN PIPE 9709631229 -> McLaughlir Water Engineers, Ltd; Page 2 9709631229 T-406 P.002/004 F-303 First -Line Defense for Your Septic System 11 � 05a patented Screened Vault Technology retains solids within the tank ensuring that high quality effluent is discharged. ou've put your money (or your reputation) into a quality septic system. Protect your investment with OSI's advanced filtration technology. The OSI Biotube® Effluent Filter dramatically improves the quality of effluent discharged from a septic tank by preventing large solids from leaving the tank. Now It Works Effluent from the relatively clear zone of the septic tank, between the scum and the sludge layers, enters the Biotube Effluent Filter through its inlet holes. Effluent then enters the space between the housing and Biotubes, utilizing the entire screen surface for filtering. Particles larger than 1/8" are detained in the interior space, where continued decomposition of organic material occurs. Once the effluent has been filtered through the Biotubes, it flows through the modulating orifices at the outlet of the filter. If inflow becomes temporarily excessive, the fluid level in the tank will rise as the modulating orifices slow the flow through the tank, allowing maximum settling of solids. 0 • r�C�.01V CU J/ o/vi IV=JVHM; `J /VLl CJJI'GL`J- -> MCLaugnlin water Engineers, Ltd; Page 3 03-i18-2001 11:16 From -GRAND JUi jN PIPE 9709631229 T-406 P.003/004 F-303 Pure Performance o• • o ' 0 F The OSI Biotube Effluent Filter i; the most advanced in the indusl engineered to provide maximun protection for your septic syster Features and Benefits • Improves effluent quality. Average Total Suspended Soli (TSS) is less than 30 PPM, ne, 2-1/2 times lower than a non - screened system! • Allows for smaller diameter drainfield pipe. Lowers drainfield material co! • Superior patented design. Extends drainfield life_ Reliably corrosion -proof construction. • Easy installation. Installs in minutes in new or existing tanks. • Simple, hassle -free maintenance. • Available alarm. Indicates when maintenance needed. • Ideal for variable -grade sewe Allows reduction of the transl line size and associated cost: • Custom sizes. Call for availability. nCl:C1VCU J/ O/VI IV: JVNMj Ll, uwaO iLGw MU uuyr111/1 VVd Luc =nglrievr' LIU� 33-08-2001 11:16 From -GRAND JU 1N PIPE 9709631229 T-406 P.OD4/004 F-303 Sizes and Applications OSI Biotube Effluent Filters are available in several diameters, suitable for a variety of applications. r and 4" models shown 4" Diameter Best for most residential applications. 6" and 8" Diameter Ideal for larger residential applications, such as large homes or duplexes, or for small commercial flows. 12" and 15" Diameter For larger commercial flows. Multiple filters may be used to accommodate larger flows. Excellent for: • Gravity Septic Tank Filters • Effluent Pumping Systems • Dosing Siphon Systems • Grease Trap Filters • Industrial Process Filtering • Groundwater Remediation • Variable -grade sewers Custom designs available to satisfy specialized needs. ASPEN/Pi. _,N ENVIRONMENTAL HEALTH DEPAR' ISDS DESIGN REQUIREMENTS -DEPARTMENT UE Name Epstein House Size (75 gpd, 100 gpd, or 130 gpc #of Bedrooms, Similar Rooms accessible to baths in Main Residence # of Bedrooms, similar rooms w/ access to bath in ATTACHED caretaker # of Bedrooms & Similar Rooms w/ access to baths in DETTACHED caret, Average Daily Waste Flow 900 # bedrooms X 2 people/br X State Review Required? no Perc Rate 30 (T) 3 equals # of Perc Holes Req Design Flo w (Q) = # bedrooms X 2 people/bedroom X gpd X 1.75 Q= 2730 Minimum tank capacity 3413 gallons Absorption Area (A= Q/5 X SQRT) A = 2991 sq. ft. of absorption area required 193 infiltrator units without reduction A maximum 30% reduction is bed- gravelless chambered system. 2093 sq.ft. with reduction 135 infiltrator units with reduction AREA NEEDED FOR STANDARD ABSORPTION TRENCHES 97 2991 Total sq ft /3 =lineal ft of trench needed 1495 96 0 A maximum �0% reduction i 17 997 lineal ft/assumed trench length of 60ft = # of 60ft trenches needed 1L # trenches minus 1 = rows of 6ft wide undisturbed soil between trenches 51 17 times 3 = total width of of 60" long field needed for just the trenches 96 16 times 6' = total width of 60' long field needed just for undisturbed soil 1_47 width of trench +width of undisturbed soil = total width needed 147 by 60 ft is the area needed for a standard absorption field in a trench configuration with no reductions taken and ASSUMING AN AVERAGE PERCOLATION RATE OF 3.4 SLOWER PERCOLATING SOILS WOULD REQUIRE MORE AREA. SETBACK FROM WELL SETBACK FROM POND, STREAM OR IRRIGATION DITCH # of feet = 238.4 # of feet = 188.4 SETBACK FROM DRY GULCH # of feet = 163.4 Remember: 8 feet of additional distance for each 100 gallons/day of design flow over 1,000 gallons/day should be added unless an RPE can verify that it is not necessary to prevent contamination. 1/20/99 Printed on Recycled Paper Permit # 20009 Type of permit Name of Owner Aspen/Pitkin Environmental Health Department Permit for an Individual Sewage Disposal System 130 S. Galena St. Aspen, Colorado 81611 Phone 970-920-5070 / FAX 970-920-5074 Parcel ID # 2735-101-01-004 New( X ) Re Dr. & Mrs. Marc E Street Address 300 IN. Eagle Pines Road Property legal description Size of lot 7.778 acres Water source City of Aspen # of bedrooms in house 5 Caretaker unit # of bedrooms in caretaker unit Designed for what # rooms (list) Addition to Housei Lot 4, Eagle Pines Sub. Total square footage of the house 319 # of offices, lofts & similar sized rooms in house Total square footage of the caretaker unit # p # of offices, lofts & similar sized rooms in caretaker unit SIX : 5 bedrooms plus 1 future bedro&h,gr attached caretaker Permit information Designed by Dean Derosier, McLaughlin Water Engineers Mailing Address 111 P AABC, Aspen, CO 81611 Perc rate 36 mpi Profile hole depth 8 ft Depth to groundwater or bedrock Septic tank capacity 35000 +8ft Absorption area 3276 sq ft, 2293 w/ 30% infiltrator reduction Comments Septic permit approved per compliance with the engineer design and specifications dated February 2, 2000. Any changes must be approved by this department and the design engineer prior to them being made. Design is for one 1,500 gallon tank then split into two equal components, System A and�ystem B. Each system has a 1,000 gallon tank followed by a 1,000 gallon dosing tank, and a disposal field witK74 to 75 units (149 units total). The engineer must be consulted for instructions on the manifod installations. Minimum horizontal distances between components of the system and physical features shall conform to the Pitkin County ISDS regulations. This department does not endorse any brand of products. The engineer must do a final inspection of th`i •i.nstallation and submit an as -built letter to this department. This department must also be called for an inspection with.a minimum of 48 hours advanced notice. Permit approved by: Date: Z I Plans and specifications of the propo ed individual sewage disposal system have been reviewed and are considered satisfactory. Permission is hereby granted to the owner or the agent to perform the work indicated in accordance with the Pitkin County ISDS Regulation in effect at the time of issue. This permit becomes invalid 6 months from the date that the permit was issued unless system construction has commenced or an extension has been approved in writing by the Department. As -built drawings must be included with this permit before the final approval will be issued. Installer: Final inspection approval Date: Go otech December 21, 1999 Hep ,i-Pawink Geotechnical, Inc. 5020 -.ounty Road 154 Glenwood Springs, Colorado 81601 Phone: 970-945.7988 Fax: 970-945-8454 hpgeo@hpgeotech.com Marc and Nancy Epstein 205 North 6th Street Aspen, Colorado 81611 Job No. 198 288 Subject: Percolation Testing, Proposed Residence, Lot 4, Eagle Pines, Pitkin County, Colorado Dear Mr. and Mrs. Epstein: As requested by Rod Dyer, we have conducted percolation testing at the subject site to evaluate the feasibility of an infiltration septic disposal system. The results of our work are presented in this report. We previously conducted a subsoil study at the subject site and presented our findings in a report dated June 3, 1998, Job No. 198 288. A profile pit and three shallow backhoe pits were excavated on November 12, 1999 at the locations shown on Fig. 1. Access on the downhill side of the building envelope was not possible due to the steep terrain and vegetation. Percolation test holes (about 12 inches in diameter and 12 inches deep) were dug in the bottom of backhoe pits and soaked one day prior to testing. The soils exposed in the percolation test holes and Profile Pit 1 consist of about 11/2 feet of topsoil overlying clayey gravel with cobbles and boulders to the profile pit depth of 8 feet. No free .water was encountered in the pits and the subsoils were slightly moist to moist. Another profile pit and three shallow backhoe pits were excavated to the north of the building envelope on December 9, 1999. Percolation test holes (about 12 inches in diameter and 12 inches deep) were dug in the bottom of backhoe pits and soaked one day prior to testing. The holes were covered with rigid foam insulation to protect against freezing overnight. The soil temperature at the time of these tests was between 34° and 39° F and no frost was indicated in the holes. The soils exposed in the percolation test holes and Profile Pit 2 consist of about 2'/2 feet of topsoil overlying clayey to silty gravel with cobbles and scattered boulders to the profile pit depth of 8 feet. No free water was encountered in the pits and the subsoils were slightly moist to moist. Marc and Nancy Epstein December 21, 1999 Page 2 Percolation tests were performed on November 13 and December 10, 1999 by a representative of Hepworth-Pawlak Geotechnical, Inc. The percolation test results are presented on Table I. The percolation test results indicate an infiltration rate between 30 and 40 minutes per inch with an average of 37 minutes per inch for the area on the uphill southwest side of the envelope. An infiltration rate between 15 and 30 minutes per inch with an average of 22 minutes per inch was indicated for the northern area tested. Based on the subsurface conditions encountered and percolation test results, a conventional infiltration septic disposal system appears feasible at the tested locations. If you have any questions or if we can be of further assistance, please call our office. Sincerely, HEPWORTH - PAWLAK GEOTECHNICAL, INC. Jordy Z. Adamso , Jr P Rev. By: SLP JZA/sd/ksm attachments cc: Dyer and Associates - Attn: Rod Dyer t APPROXIMATE SCALL t3370 8380 1" = 60'/ / ♦ 100 �o/ ♦ ♦ / 8390 / / / 8400 001.01 8370 / 4-1 de Ile / 8410 8380� � / .n.� / ..r ' ,yam EXISTING NORDIC TRAIL / 8390 -- —-------- ._..—_--_...-7/._ / 8400 -- ! _ _ _ ` — — — / 8420 LOT 4 8410 '� _ ��-�♦ / / 8430 8420 ..r 00, 00 8430— ' 1 — � � � / ����.��,+...'�' 8440 LOT 3 P�..—._. r/ ........_----- \�' 8450 P5 PROVLE PIT 2 8440 Q -� LOT 5 ' BORING 3 � ��'• � /�� 8460 A ♦♦rte BORING 2 '���� we BORINGS DRILLED PROFILE PIT 1 / ♦ � 8470 --- FOR PREVIOUS STUDY / / / BUILDING BORING 1�/Q QP2 ENVELOPE // PLl , 0 / q P3 8450 8460 BROAD SWALE ACCESS DRIVE I 8470 198 288 HEPWORTH - PAWLAK I LOCATION OF PERCOLATION TEST HOLES I Fig. 1 GEOTECHNICAL. INC. ri S, HEPWORTH-PAWLAK GEOTECHNICAL, INC. TABLE I PAGE 1 OF 2 01:Rrn1 ATIMU TEST RESULTS JOB NO. 198 288 HOLE NO. HOLE DEPTH (INCHES) LENGTH OF INTERVAL (MIN) WATER DEPTH AT START OF INTERVAL (INCHES) WATER DEPTH AT END OF INTERVAL (INCHES) DROP IN WATER LEVEL (INCHES) AVERAGE PERCOLATION RATE (MIN./INCH) P-1 36 10 61/2 6 114 1/4 40 61/4 6 1/4 6 53/4 114 53/4 5 112 1/4 61/2 5 114 1/4 5114 5 1/4 5 43/4 114 4 314 41/2 114 P-2 38 10 7 63/4 1/4 40 63/4 61/2 114 61/2 61/2 0 61/2 61/4 1/4 61/4 6 114 6 53/4 1/4 53/4 51/2 1/4 51/2 51/4 1/4 P-3 37 10 7 61/2 1/2 30 61/2 6 114 114 61/4 53/4 112 51/2 1/4 ---63/4 51/2 5 114 114 51/4 5 114 5 4 112 112 41/2 41/4 1/4 Note: Percolation test holes were hand dug in the bottom of backhoe pits, soaked and covered with rigi� insulation on November 12, 1999. Percolation tests were conducted on November 13, 1999. The average percolation rates were based on the last three readings of each test. HEPWORTH-PAWLAK GEOTECHNICAL, INC. TABLE I PAGE 2 OF 2 PERCOLATION TEST RESULTS Juts Nu. -I U6 ZOO HOLE NO. HOLE DEPTH (INCHES) LENGTH OF INTERVAL (MIN) WATER DEPTH AT START OF INTERVAL (INCHES) WATER DEPTH AT END OF INTERVAL (INCHES) DROP IN WATER LEVEL (INCHES) AVERAGE PERCOLATION RATE (MIN./INCH) P•4 51 10 15 water added 61/2 5114 1 114 30 51/4 4 3/4 112 43/4 41/4 1/2 4 114 33/4 1/2 61/4 51/2 314 51/2 5 112 5 41/2 1/2 41/2 4 112 P-5 55 10 15 water added 9 7 112 1 1/2 15 71/2 6 1 112 6 41/2 1 1/2 41/2 3 1 1/2 73/4 6 1/2 1 114 61/2 5 112 1 51/2 41/2 1 41/2 31/2 1 P-6 40 10 15 water added 10114 91/4 1 20 91/4 8 1 1/4 s 63/4 1 114 63/4 51/2 1 1/4 7 6 1 6 51/2 1/2 51/2 41/2 1 4 112 33/4 3/4 e hand dug in e bottom of backhoe ts, soaked nd covered with n on Note: Percolation test 1999!ePe Percolation on tests were ed on Decembeir 10, 1999.aThe average percolationso December 9, rates were based on the last three readings of each test. ASPEN/PITKIN ENOVIRONMENTAL HEALTH DEPARIIA' ENT ISDS DESIGN CALCULATIONS Owners Name y� Parcel ID # «»...�, , ¢ �� House Size (sq. ft.) ,.r (75 gpd, 100 gpd, or 130 gpd) Number of Bedrooms in Main House Number of Offices, Libraries, Studies, Similar -sized Rooms in Main House Number of Bedrooms in Detached Caretaker unit Number of Offices, Studies, Similar -sized Rooms in Caretaker Unit (If the caretaker unit is ATTACHED, treat as if part of main house.) Average Daily Waste Flow 1560 State Review Required? no Perc Rate (T) Design Flow (Q) = # potential bedrooms X 2 people/bedroom X gpd X 1.75 Q = 2730 Absorption Area (=Q/5 X SQRT perc rate) A = 3276 sq. ft. of absorption area required 211 gravelless chamber units without reduction # of Perc Holes Required: 3 1 in every soil type? Spaced uniformly over proposed area? A maximum 30% reduction is allowed for use of deep gravel or gravelless chambered system, only if the lot size and soil conditions are optimal. If a reduction is being proposed, describe why lot size and soil conditions are optimal: A = 229 -a.2 -so. ft. with reduction 148 pravelless chamber units with reduction Type of system: []Absorption trenches []Absorption bed [] Gravelless chambers []Dry well []Seepage Pit []Other (type) Minimum tank capacity 3412.5 gallons SETBACK FROM WELL # of feet = 238.4 SETBACK FROM POND, STREAM OR IRRIGATION DITCH # of feet = 188.4 SETBACK FROM DRY GULCH # of feet = 163.4 Printed on Recycled Paper 130 00V2l0-100 'N3dSV S.IOlaalui a.InjoaligDaDN131Sd3 MW4 'S6A 'da ° o -D-d Da I DJDIDia :d03 30N3GIS36 M3N 4w 0 Z m G 0 OUVRO100 'N3dSV ::;K1 N131Sd3 ONJVA 'SW4 V -�Ja :JOJ 3:DN3CIIS3H M3N 0) CD gdlDji OGVHOI03 'N3dSV sJolialul N131Sd3 OdVN *SWN V 'dG -a-d 0@ 0) :NOA 30N3GIS3N M3N 44!q3_JD C; Ll 0 m„ . 0 0 Ln sa0palUf aan0aligaa0) N131Sd3 O�Wh o -d as i aao `.J :dOJ 30N30IS38 M3N � �.0 o �� �d �o N C 0 C OOVWIOJ 'N3dSV saoiaa u+ asn��a�iy ap N131Sd3 ONVA 'SNN V '?JG s Q od as i aaa�.J :WA 33NKIS3d M3N � IrDil- 0- N OaVV01W 'N3dSV ED S-Jouajul @j nloaliqojD N131Sd3 O2AVV4 'SIA V *�Rl s < :HOJ 33N3GIS3?J M3N -D -d joal! qo-jo 19 0 u 3 d FT I cw N— 1 0 G Mull OaVE0100 'N3dSV siolialul N131Sd3 O�JVVN .D -d 0@;!qDJD :�JO-J 3ON3GIS3H M3N ; 3 aj P., 0 OGVHO'lOO 'N3dSV siolialul N131Sd3 DNVV4 'SW4 V *�a .D :NOJ 3ON3(]IS3?J M3N -d go q 3 qdlc)il c . ..... ............ ... Q 0 SaoiaaI UI aanloGllgOao •a•d Oa i Oap R 0 U:D qdliDi _j -_j I :a 4 1 a oaV8OIO3 'N3dsv Lli N131Sd3 OLIVA 'S�JW ?8 '�1a o V) :�]Od 33N3GIS3?l M3N EXISTING AND FUTURE GROUND BACKFILL - 3'MINUS MAX, 6' - TOP SOIL BEDDING ZONE - FINE NATIVE MATERIAL NO LARGER THAN 1' IN DIAMETER WITHIN 6 ' OF INFILTRATOR vvv vv vvv vvvvvvv vv v vvv vv vvv v v / v v INFILTRATOR NOTES= BYSTEM TO BE 1N57ALLEC PER DESIGN NOTES BY MIUE ANO PER PITKIN COUNTY ISDS 2001 REGULArONS ENGINEER TO VERH=Y rANK AND SYSTEM /- OCAT10N5 AND EL-1Ar/ON.5 WATER 6y -6M7"1 /S COASPEN PUBLIC SYSTEM 6 - 90 -FOOT AND 1 - 48 -FOOT INFILTRATOR TRENCHES 15 UNITS IN 6 ROWS AND 1 W/ 8 - 98 TOTAL TRENCHES, IE TO BE FIELD DETERMEINED MINIMUM DEPTH IS 3 -FOOT TO BOTTOM OF TRENCH, 10' APART MINIMUM, MAX DEPTH IS 6' IE TO BE F'IELD DETERMINED BY ENGINEER V 4' SDR PVC PIPING TO EACH END OF INFILTRATOR TRENCHES INSTALL OPEN TEE AT EACH TRENCH TRENCH DETAIL FOUND REBAR & CAP %LS. 15710 1/ ELEC. PEDESTAL ELEC. TRANSFORMER TELE. PEDESTAL PAVEMENT I IN5r4f-L 4"6DR 35 FROM F,2/S,E r0 SEPrk, 7,4NK 4NC TANK To SYSTEM .81 ANSTALL Y,ERrA:;;4L BENDS A$ AdSSMW /N L//VE r0 -51-CFE SLOPE MATCH AA$rALL / 2000 GALLON SEPrC \ rANK wlh4 Blonoe Oiv Emma-wr LINE E OF TANK rO BE SET BY ENG - 128.o LCCArE TANK ro eESr F/r SITE AAQ7 f lh1P/NG A?EaOeSr�6 /NSTALL CLEAA10Ur5 - � 100 AND Ar AU BEI M�111 30' WIDE ACCESS /T EASEMENT TO LOT 6 BK. 629, PG. 594 18' DATE I in - I REVISIDN Ir ID REBAR & CAP 20133 VALVE BY Iac*10 LOT 3 iER' 60i WIDE ROAI EASEMENT 1 PROFILE HOLE • (BK. 246, PG. 1 PERCOLATION TEST HOLES 4 1 1. ,�Ilill 1 F 1 35 TO 1 1 \2L L LOT 5 LOT 5 i FOUND REBAR & CAP L.S. 15710 EXISTING I FENCE FOUND REBAR & CAP L.S. 15710 TRENCH SYSTEM- 8 TOTAL RCW$ I SYSTEM 2= FOLLGYUS 6 ROICGS OF 15 UNITS AND 2 RCU6 OF i' UMTS ovERHEAD CONTOURS AND FOR 104 TOTAL ROWS ARE TO BE 10 ' PART UTILITIES ACRg5S-R! AAl1 FLATS STEP DOIUN TO MATCH CONTOURS OF .SITE, ?%sz ANP3-2 RCW 4 RCIUS FOLLC:U HILLSIDE AND 3 RCU6 rOT4L ARE LOCATED ON THE R� AND FLS r AREAS. INSTALL YENT5 ON EVERY oz-1ER ROIU SYSTEM P FOL -CWIS CON70UR6 AND SrEPS COG/N HILL5/CE 4 RCU6 0C /5 UMTS/ 60 TOTAL REBAR & CAP 184 \/M3rAL - 4" TEE r0 i €4CH 2 RCU6 OF UN10 ,AND AGAIN TO =7C ACH RCw OF /NF/L TRArCR /NSTALL 4"S CH 40 PVC FROM TANK rO SFLIrrER BOX AND BOX r0 SYSTEM 1NSrALL CoNCI�rE 5PLjl7 BOX r01o1vr E FL01U EVENL Y 8 O 1NT0 EACH SY57FM _ a \ FOUND REBAR & CP \\ _Y L.S. 15716\ � N C8 POWER POLE GRAPHIC SCALE O 0 20 40 80 1e ( IN FEET ) 1 inch = 40 ft PROJECT NUMBER AO -004.01 DESIGN: GDD DETAIL: GOD CHECK: DATE: 501 IGLEHART CONSTRUCTION CO. 617 WEST MAIN STREET ASPEN, CO 81611 PH: (970) 925-5990 FAX: 925-5485 h1 AY 1 4 2001 f --------------1 EPSTEIN a3�oy1PPhP,�,,/��� SEPTIC SYSTEM —771 i SITE PLAN DETAILS AND NOTES , F - w `\1 2420 Alcott Street, Denver, CO 80211 PH. 303.458.5550; Fat 303.480.9 666 email mwe@mwewat�.com LOT 5 LOT 5 i FOUND REBAR & CAP L.S. 15710 EXISTING I FENCE FOUND REBAR & CAP L.S. 15710 TRENCH SYSTEM- 8 TOTAL RCW$ I SYSTEM 2= FOLLGYUS 6 ROICGS OF 15 UNITS AND 2 RCU6 OF i' UMTS ovERHEAD CONTOURS AND FOR 104 TOTAL ROWS ARE TO BE 10 ' PART UTILITIES ACRg5S-R! AAl1 FLATS STEP DOIUN TO MATCH CONTOURS OF .SITE, ?%sz ANP3-2 RCW 4 RCIUS FOLLC:U HILLSIDE AND 3 RCU6 rOT4L ARE LOCATED ON THE R� AND FLS r AREAS. INSTALL YENT5 ON EVERY oz-1ER ROIU SYSTEM P FOL -CWIS CON70UR6 AND SrEPS COG/N HILL5/CE 4 RCU6 0C /5 UMTS/ 60 TOTAL REBAR & CAP 184 \/M3rAL - 4" TEE r0 i €4CH 2 RCU6 OF UN10 ,AND AGAIN TO =7C ACH RCw OF /NF/L TRArCR /NSTALL 4"S CH 40 PVC FROM TANK rO SFLIrrER BOX AND BOX r0 SYSTEM 1NSrALL CoNCI�rE 5PLjl7 BOX r01o1vr E FL01U EVENL Y 8 O 1NT0 EACH SY57FM _ a \ FOUND REBAR & CP \\ _Y L.S. 15716\ � N C8 POWER POLE GRAPHIC SCALE O 0 20 40 80 1e ( IN FEET ) 1 inch = 40 ft PROJECT NUMBER AO -004.01 DESIGN: GDD DETAIL: GOD CHECK: DATE: 501 IGLEHART CONSTRUCTION CO. 617 WEST MAIN STREET ASPEN, CO 81611 PH: (970) 925-5990 FAX: 925-5485 h1 AY 1 4 2001 f --------------1 EPSTEIN a3�oy1PPhP,�,,/��� SEPTIC SYSTEM —771 SITE PLAN DETAILS AND NOTES , F - w 2420 Alcott Street, Denver, CO 80211 PH. 303.458.5550; Fat 303.480.9 666 email mwe@mwewat�.com C C NUMBER J J