Loading...
HomeMy WebLinkAboutpitkin.bldg.246313301008 (2018)DOCUMENT LAYOUT Certificate of Occupancy or Letter of Completion Permits Final Inspections Any Supporting Documents Site Plans (NOTE: All structural plans will be grayed out. If you require the ability to see structural plans, you must have a letter from the owner stating you are allowed to have plans. This letter must be submitted to Pitkin County Community Development Department) PERMITS PITKIN COUNTY COMMUNITY DEVELOPMENT 130 S Galena St Third Floor Aspen CO 81611 INSPECTION LINE 970-920-5532 PH: 970-920-5526 FX: 970-920-5439 0345.2017.PELE PERMIT NO. (Office Use Only) JOB ADDRESS 499 BULLWINKLE CIR. ASPEN CO 81611 OWNER PHONE WILSON GARTH PO BOX 11326 ASPEN CO 81612 ELECTRICAL CONTRACTOR MAILING ADDRESS PHONE ELECTRICAL OUTFITTERS INC 1500-A DEVEREUX RD GWS CO 81601 945-5793 BI JILDING FFOOTAGE ISTMD ALONE FRESIDENTIAL $ 2,500.00 110 USE OF BUILDING COMMERCIAL FRESIDENTfAL CLASS OF WORN 1:1 IMALTERATION ❑NEW ] CONSVRU TION 1:1 ®SOLAR 1[]OTHER DESCRIBE WORK IN DETAIL (For additions, alterations, indicate type, number and focation of source of circuits) REPLACING THE EXISISTING 100AMP OUTDOOR FEDERAL PACIFIC PANEL WITH A NEW OUTDOOR PANEL AND INSTALLING POWER TO A NEW SEPTIC SYSTEM CONTROL BOX Tiffany@electoutfitters.com 2643-22-3-02-001 OWNER: The undersigned applicant to personally perform electrical work on the described property or residence hereby certifies, as a condition of issuance of such permit, that the above described property or residence is owned by the applicant: that the applicant is not in the business of construction or remodeling; and „engaged such property Is not intended for sate or resale, nor is It rental property (occupied or to be occupied by tenants. whether transient or permanent), nor will it be generally open to the public. It is understood that compliance with these assurances is a condition of the issuance of an electrcal permit to the applicant pursuant to the provisions of C.R.S. Section 12-23-111 (2) (as amended), and that failure to comply herein will be grounds for revocation of the electrical permit or any certificate of occupancy issued with respect to the property or residence described. DO NOT SIGN THIS SECTION IF YOU AREA LICENSED CONTRACTOR. Signature of Owner r Date: Note; Engineer stamped electrical one -line plan required if service is over 400 amps. Low voltage drawings must be done by NICET engineer. PAYMENT OF PITKIN COUNTY USE TAX Tax I Permit Fee I Dauhle The General Contractor or Owner Builder Is required to pay a Use Tax Deposit to Pitkin County (.5%) an the building permit valuation at time of issuance. All sub -permits pulled under a building permit are paid by this deposit payment and should not pay Use Tax. Stand alone sub -permits are $ 6.25 $201 .8 4 111 1 required to pay a Use Tax Deposit to Pitkin County (.5%) Deposit .5% of 50% of project valuation. Approved by Fire Marshal Project Valuation (includes labor) $ Date: Exempt: Exempt Organization Approved by HPC Tax Exempt ID Number 0488376 Property lions may be placed on the owner's and/or the contractor's property Date: when Use Tax is not paid. ELECTRICAL, CONTRACTOR For all work done under this permit, the permittee accepts full responsibility for compliance with the Building Department Acceptance National Electric Coda and County resolutions, and/or state laws, whichever applies, Permit subject to revocation or suspension for violation of any governing same. An accepted final electrical inspection shall be obtained prior to using the electrical system. A final electrical Approved By: inspecti n she be requested within 48 hours after completing an electrical installation. � - �' E r� _ ,_.._... 11-17-17 Signature a'. tical Carstractor Date �f Date: 11/29/17 Permit Validation Date I Receipt # Total 12/6/17 43479 [�208_09 TIFFANY B. EGGLESTON TREASURER Print Name Begin Building Review Effective Date 06/05/2017 11/27/2017 APPLICATON MATERIAL ONSITE WASTEWATER TREATMENT SYSTEM (OWTS) CONSTRUCTION PERMIT 76 Service Center Rd- Aspen, CO • 81611 Phone: 970.920.5070 Fax: 970.920.5374 Permit #: 0044.2017.POWT Parcel ID #: 2643-223-02-006 Permit Issued: ❑NEW ®REPAIR ❑REMODEL/ADDITION ❑TANK ONLY ❑FIELD ONLY ❑AMENDMENT Owner(s): Garth Wilson Property Address 499 Bullwinkle Circle Legal Description: Lot 1 Block 2 Filing 3 W/J Ranch Homes Size of Lot: 0.466 Size of Building: 1126 ft2 Acres Detached Accessory Unit: ❑YES ®NO Size of Accessory Unit: This system is designed to serve 2 bedrooms Designed By: Phone #: Fax #: All Service Septic Project #: 970-704-0484 Mailing Address: Email Address: C1310 Dated: September 30, 2017 LTAR: 0.5 (TL 3, sand filter) Profile Hole Depth: 7' Depth to Groundwater or Bedrock Minimum Tank Capacity: 1000 gal. Minimum Absorption Area: 600 ft2 Permit Conditions: ➢ 7' This OWTS Construction Permit is approved on the condition of compliance with the engineer design as submitted with the application and the specifications cited above. Changes must be approved by this Department and the engineer prior to construction. This permit is for the replacement of a shared OWTS system that has failed (Shared with 489 Upper Bullwinkle, now on permit # 0037.2017.POWT). This new system will no longer be a shared system and will only serve the existing 2 bedroom residence at this address. The existing OWTS shall be abandoned properly and evidence of proper abandonment shall be submitted to this department for final approval of this permit. Sewage will flow via gravity to a new 1000 -gallon, two-compartment poly septic tank with an effluent filter installed on the outlet tee. Effluent will then flow via gravity to a new 500 -gallon poly pump tank with an Orenco pump. Effluent will be pumped to an automatic distribution valve (ADV) and then to an unlined sand filter soil treatment bed with 2 zones. The sand bed will be 15' X 40' and three feet deep with (2) 1.5" distribution pipes per zone. Due to this permit being a repair and the proposed system cannot meet the required setbacks for the property line and residence, the STA may violate these setbacks. Water line and cistern setbacks shall be maintained. This Permit must be kept on-site during installation. The engineer must do a final inspection of the installation and submit an "as -built" letter to this Department within 30 days of the final inspection, unless a longer period of time has been agreed upon, in writing. This Department must also be called for the final inspection with a minimum of 48 hours notice. Minimum horizontal distances between components of the system and physical features shall conform to the requirements of the Pitkin County OWTS Regulation. This Permit is conditioned upon the property owner(s) providing for regular inspection, cleaning, and maintenance of the system by qualified personnel, in accordance with the manufacturer's recommendations and the requirements of the Pitkin County OWTS Regulation. Issuance of this OWTS Construction Permit does not constitute a guarantee, warranty, or representation by the Department that the system will operate properly or will not fail. Issuance of this permit does not imply compliance with Pitkin County building and/or land use regulations, nor guarantee issuance of building and/or land use permits. THIS PERMIT IS EXPRESSLY CONDITIONED UPON COMPLIANCE WITH ALL REQUIREMENTS OF THE PITKIN COUNTY OWTS REGULATION, INCLUDING BUT NOT LIMITED TO THOSE CONDITIONS SPECIFIED ABOVE. Plans and specifications for the proposed OWTS have been reviewed and are considered satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated in accordance with the Pitkin County OWTS Regulation. This Permit will expire 1 year from the date of issuance unless construction on the system has commenced. An "as -built" drawing must be submitted and approved by EH before final approval of the system will be issued. Issued By: Kurt Dahl, REHS Date: 11/03/2017 Expires: 11/03/2018 Installer: License #: Reactivation Authorized by: Final Approval Issued By: Date: New Expiration Date: ❑ Fime paw Begin Building Review 11/27/2017 PLANS These plans must be kept at building ing 0345.2017.PELE site or inspection delays may occur. Construction shall conforms to these plans. All Changes shall be approved by the building official. MP CE EXISITIN -ADD --POWER-TO _NEjq0j!ii MRAL PACIFIC L ---SE PT I a AWNWAgift A NEW 100/1 5A PANEL_- BE MOUNTED ON 'THIS E L�APM 7 0_1 A INSTAL G Reviewed Electrical jeffrey.erickson 11/29/2017 Begin Building Review 11/271201 WIRES ILI -