HomeMy WebLinkAboutpitkin.bldg.246313301008 (2018)DOCUMENT
LAYOUT
Certificate of Occupancy or Letter of Completion
Permits
Final Inspections
Any Supporting Documents
Site Plans
(NOTE: All structural plans will be grayed out. If you require the ability to see structural
plans, you must have a letter from the owner stating you are allowed to have plans. This
letter must be submitted to Pitkin County Community Development Department)
PERMITS
PITKIN COUNTY COMMUNITY DEVELOPMENT
130 S Galena St Third Floor Aspen CO 81611
INSPECTION LINE 970-920-5532 PH: 970-920-5526 FX: 970-920-5439
0345.2017.PELE
PERMIT NO. (Office Use Only)
JOB ADDRESS
499 BULLWINKLE CIR. ASPEN CO 81611
OWNER
PHONE
WILSON GARTH
PO BOX 11326 ASPEN CO 81612
ELECTRICAL CONTRACTOR
MAILING ADDRESS
PHONE
ELECTRICAL OUTFITTERS INC
1500-A DEVEREUX RD GWS CO 81601
945-5793
BI JILDING FFOOTAGE
ISTMD ALONE
FRESIDENTIAL $ 2,500.00
110
USE OF BUILDING
COMMERCIAL
FRESIDENTfAL
CLASS OF WORN
1:1
IMALTERATION
❑NEW ] CONSVRU TION
1:1
®SOLAR
1[]OTHER
DESCRIBE WORK IN DETAIL (For additions, alterations, indicate type, number and focation of source of circuits)
REPLACING THE EXISISTING 100AMP OUTDOOR FEDERAL PACIFIC PANEL WITH A NEW OUTDOOR PANEL AND
INSTALLING POWER TO A NEW SEPTIC SYSTEM CONTROL BOX
Tiffany@electoutfitters.com
2643-22-3-02-001
OWNER: The undersigned applicant to personally perform electrical work on the described property or residence hereby certifies, as a condition of issuance of such permit,
that the above described property or residence is owned by the applicant: that the applicant is not in the business of construction or remodeling; and
„engaged
such property Is not intended for sate or resale, nor is It rental property (occupied or to be occupied by tenants. whether transient or permanent), nor will it be
generally open to the public. It is understood that compliance with these assurances is a condition of the issuance of an electrcal permit to the applicant pursuant to the
provisions of C.R.S. Section 12-23-111 (2) (as amended), and that failure to comply herein will be grounds for revocation of the electrical permit or any certificate of
occupancy issued with respect to the property or residence described. DO NOT SIGN THIS SECTION IF YOU AREA LICENSED CONTRACTOR.
Signature of Owner r Date:
Note; Engineer stamped electrical one -line plan required if service is over 400 amps. Low voltage drawings must be done by NICET engineer.
PAYMENT OF PITKIN COUNTY USE TAX
Tax
I Permit Fee
I Dauhle
The General Contractor or Owner Builder Is required to pay a Use Tax Deposit to Pitkin County
(.5%) an the building permit valuation at time of issuance. All sub -permits pulled under a building
permit are paid by this deposit payment and should not pay Use Tax. Stand alone sub -permits are
$ 6.25
$201 .8 4 111
1
required to pay a Use Tax Deposit to Pitkin County (.5%) Deposit .5% of 50% of project
valuation.
Approved by Fire Marshal
Project Valuation (includes labor) $
Date:
Exempt: Exempt Organization
Approved by HPC
Tax Exempt ID Number 0488376
Property lions may be placed on the owner's and/or the contractor's property
Date:
when Use Tax is not paid.
ELECTRICAL, CONTRACTOR
For all work done under this permit, the permittee accepts full responsibility for compliance with the
Building Department Acceptance
National Electric Coda and County resolutions, and/or state laws, whichever applies, Permit
subject to revocation or suspension for violation of any governing same. An accepted final
electrical inspection shall be obtained prior to using the electrical system. A final electrical
Approved By:
inspecti n she be requested within 48 hours after completing an electrical installation.
� - �' E r� _ ,_.._... 11-17-17
Signature a'. tical Carstractor Date
�f
Date: 11/29/17
Permit Validation
Date
I Receipt #
Total
12/6/17
43479
[�208_09
TIFFANY B. EGGLESTON TREASURER
Print Name
Begin Building Review Effective Date 06/05/2017
11/27/2017
APPLICATON
MATERIAL
ONSITE WASTEWATER TREATMENT SYSTEM (OWTS)
CONSTRUCTION PERMIT
76 Service Center Rd- Aspen, CO • 81611
Phone: 970.920.5070 Fax: 970.920.5374
Permit #: 0044.2017.POWT Parcel ID #:
2643-223-02-006
Permit Issued: ❑NEW ®REPAIR ❑REMODEL/ADDITION ❑TANK ONLY ❑FIELD ONLY ❑AMENDMENT
Owner(s): Garth Wilson
Property Address
499 Bullwinkle Circle
Legal Description: Lot 1 Block 2 Filing 3 W/J Ranch Homes
Size of Lot: 0.466
Size of Building: 1126 ft2
Acres Detached Accessory Unit: ❑YES ®NO
Size of Accessory Unit:
This system is designed to serve 2 bedrooms
Designed By:
Phone #:
Fax #:
All Service Septic Project #:
970-704-0484 Mailing Address:
Email Address:
C1310
Dated: September 30, 2017
LTAR: 0.5 (TL 3, sand filter) Profile Hole Depth: 7' Depth to Groundwater or Bedrock
Minimum Tank Capacity: 1000 gal. Minimum Absorption Area: 600 ft2
Permit Conditions:
➢ 7'
This OWTS Construction Permit is approved on the condition of compliance with the engineer design as submitted with the application and the specifications
cited above. Changes must be approved by this Department and the engineer prior to construction.
This permit is for the replacement of a shared OWTS system that has failed (Shared with 489 Upper Bullwinkle, now on permit
# 0037.2017.POWT). This new system will no longer be a shared system and will only serve the existing 2 bedroom residence
at this address. The existing OWTS shall be abandoned properly and evidence of proper abandonment shall be submitted to
this department for final approval of this permit.
Sewage will flow via gravity to a new 1000 -gallon, two-compartment poly septic tank with an effluent filter installed on the
outlet tee. Effluent will then flow via gravity to a new 500 -gallon poly pump tank with an Orenco pump. Effluent will be pumped
to an automatic distribution valve (ADV) and then to an unlined sand filter soil treatment bed with 2 zones. The sand bed will
be 15' X 40' and three feet deep with (2) 1.5" distribution pipes per zone. Due to this permit being a repair and the proposed
system cannot meet the required setbacks for the property line and residence, the STA may violate these setbacks. Water line
and cistern setbacks shall be maintained.
This Permit must be kept on-site during installation. The engineer must do a final inspection of the installation and submit an "as -built" letter to this
Department within 30 days of the final inspection, unless a longer period of time has been agreed upon, in writing. This Department must also be called for
the final inspection with a minimum of 48 hours notice.
Minimum horizontal distances between components of the system and physical features shall conform to the requirements of the Pitkin County OWTS
Regulation.
This Permit is conditioned upon the property owner(s) providing for regular inspection, cleaning, and maintenance of the system by qualified personnel, in
accordance with the manufacturer's recommendations and the requirements of the Pitkin County OWTS Regulation. Issuance of this OWTS Construction
Permit does not constitute a guarantee, warranty, or representation by the Department that the system will operate properly or will not fail. Issuance of this
permit does not imply compliance with Pitkin County building and/or land use regulations, nor guarantee issuance of building and/or land use permits.
THIS PERMIT IS EXPRESSLY CONDITIONED UPON COMPLIANCE WITH ALL REQUIREMENTS OF THE PITKIN
COUNTY OWTS REGULATION, INCLUDING BUT NOT LIMITED TO THOSE CONDITIONS SPECIFIED ABOVE.
Plans and specifications for the proposed OWTS have been reviewed and are considered satisfactory. Permission is hereby
given to the property owner(s) to perform the work indicated in accordance with the Pitkin County OWTS Regulation. This
Permit will expire 1 year from the date of issuance unless construction on the system has commenced. An "as -built" drawing
must be submitted and approved by EH before final approval of the system will be issued.
Issued By: Kurt Dahl, REHS
Date: 11/03/2017 Expires:
11/03/2018
Installer:
License #:
Reactivation Authorized by:
Final Approval Issued By:
Date:
New Expiration Date: ❑ Fime paw
Begin Building Review
11/27/2017
PLANS
These plans must be kept at building
ing 0345.2017.PELE
site or inspection delays may occur.
Construction shall conforms to these
plans. All Changes shall be approved
by the building official.
MP CE EXISITIN -ADD --POWER-TO _NEjq0j!ii
MRAL PACIFIC L ---SE PT I a AWNWAgift
A NEW 100/1 5A PANEL_- BE MOUNTED ON 'THIS
E
L�APM
7
0_1
A
INSTAL
G
Reviewed
Electrical
jeffrey.erickson
11/29/2017
Begin Building Review
11/271201
WIRES
ILI -