HomeMy WebLinkAboutpitkin.planning.264334405053 (2018)[=� BLACK & VEATCH Building a world of difference: Suzanne Wolff- Assistant Director Pitkin County Community Development 130 S. Galena St, 3rd Floor Aspen, CO 81611 970-920-5093 Verizon Wireless (CO3 Aspen Airport) JUNE 11, 2018 Pitkin County — Special Review for a Wireless Communications Facility Verizon Wireless - Sectorization (CO3 Aspen Airport) 301 Aspen Airport Business Center, Aspen Co 81611 Parcel #264334405053 Dear Ms. Wolff; I'm writing to you on behalf of Verizon Wireless (VAW) LLC d/b/a Verizon Wireless which operates a wireless communications facility located on the property at the above-mentioned address. As we discussed Verizon Wireless is in the process of updating its existing infrastructure to accommodate advanced LTE technologies, and utilize acquired AWS/ PCS spectrum. It is necessary to upgrade the existing omni antennas and install new panel antennas. In reference to the Special Review for a Wireless Communications Facility application, please find enclosed the following documentation; • Signed Pitkin County Community Development Agreement • Check for review fees totaling $2,054 • Summary Letter - Compliance with County Land Use Code & Application Manual • Scenic View Protections Exhibits — Photo Simulations • Parcel Description and Vicinity Map • Copies of all resolutions and ordinances • Proof of Ownership — Title • Consent Letters; Owner / Aspen Business Center / Verizon • List of Property Owners within 300 • Copy of Pre -application Summary • Plan Set (1) 11"x17 & (1) 24"x36" Should you have any questions or concerns I can be reached at (303) 256-4079 or Nebel C(a_bv.com Sincerely, Colleen Nebel Site Acquisition Associate Black & Veatch Corp. Agent for Verizon Wireless Page 1 of 1 Colleen Nebel I Site Acquisition Specialist I Telecommunications Black & Veatch 14600 S. Syracuse St. Denver, CO 80237 +1303-256-4079 r I NebelC@BV.com PITKIN COUNTY COMMUNITY DEVELOPMENT DEPARTMENT AGREEMENT FOR PAYMENT OF LAND USE APPLICATION FEES PITKIN COUNTY (hereinafter COUNTY) and (hereinafter APPLICANT) AGREE AS FOLLOWS: 1. APPLICANT has submitted to COUNTY an application for (hereinafter, THE PROJECT). 2. APPLICANT understands and agrees that Pitkin County Ordinance No. 012-2016 establishes a fee structure for land use applications and the payment of all processing fees is a condition precedent to a determination of application completeness. The fee structure is based on the County's policy that development shall pay, in full, the cost of development review in Pitkin County. Fees have been set to be consistent and fair to the public and to reflect the expense incurred in providing such services to the public. 3. APPLICANT and COUNTY agree that because of the size, nature or scope of the proposed project, it may not be possible at the time of application to ascertain the full extent of the costs involved in processing the application. 4. APPLICANT and COUNTY agree that fees charged for the processing of land use applications shall accumulate if an application includes more than one type of land use review. 5. COUNTY and APPLICANT further agree that it is impracticable for COUNTY staff to complete processing or present sufficient information to the Planning Commission and/or Board of County Commissioners to enable the Planning Commission and/or Board of County Commissioners to make legally required findings for project approval, unless current billings are paid in full prior to decision. 6. Therefore, APPLICANT agrees that in consideration of the COUNTY's waiver of its right to collect full fees prior to a determination of application completeness, APPLICANT shall pay a base fee in the amount of $ which is based on _ hours of staff time, and if actual time spent by staff to process the application exceeds the average number of hours by more than 20%, then the COUNTY will bill the APPLICANT quarterly for the additional time spent. Such periodic payments shall be made within 30 days of the billing date. APPLICANT further agrees that failure to pay such accrued costs shall be grounds for suspension of processing. PITKIN COUNTY APPLICANT Cindy Houben Community Development Director Print 2e1 �4 e Signature ^ Date: Mailing Address: Lao ��0�37 L77] BLACK & VEATCH Building a World of difference: Pitkin County — Special Review for a Wireless Communications Facility Verizon Wireless - Sectorization (CO3 Aspen Airport) 301 Aspen Airport Business Center, Aspen Co 81611 Parcel #264334405053 Summary Letter Property Owner Burkholder Investments, LTD Attn: Craton Burkholder 1596 W. Buttermilk Road Aspen, CO 81611 Site Name: Site Address: Equipment Area Antennas Parcel Area: Parcel #: Zoning: Process: Planner: Request: Request & Justification Applicant Applicant's Representative Verizon Wireless Colleen Nebel 3131 S. Vaughn Way Black & Veatch Corp. Aurora, CO 80014 4600Syracuse St. Denver, CO 80237 CO3 Aspen Airport (Sectorization) 301 AABC, Aspen, CO 81611 310 sq. ft. (inside the office building) + Space on Rooftop for 23,837+/- sq. ft. 2643-344-05-053 B-2, General Business Special Review Suzanne Wolff Special Review approval to modify the original approval to allow the addition of two (2) new omni antennas and equipment on an existing building rooftop in the B-2 Zone District. Verizon Wireless is the nation's largest wireless telecommunication provider with over 116 million subscribers is in need of upgrading its antennas at an existing facility located at the above referenced address in order to ensure that adequate and uninterrupted service is maintained at all times per their License Agreement with the Federal Communications Commission (FCC) as well as provide the residents, businesses, and traveling public in the area with new and faster voice and data services through the deployment of advanced AWS LTE/4G technology. This site remains a critical component to the overall Verizon Wireless network and carries a high volume of call traffic every day making this an important site to receive these technological upgrades and remain in service. Verizon Wireless is in the process of updating its existing infrastructure to accommodate advanced LTE technologies, and utilize acquired AWS spectrum. It is necessary to upgrade the existing omni antennas and install new panel antennas. Verizon Wireless, through its agent and with the full cooperation of the parent parcel property owner, (Burkholder Investments LTD) as well as the Aspen Business Center, are proposing to upgrade the antennas and equipment that is currently located on the building rooftop (See attached plans for details). The subject property is a 0.44 acre parcel located in the Aspen Business Center development on the east side of the Hwy 82 and the airport as more particularly described on the enclosed plans, legal description and Vicinity Map. Per the BOCC resolution No. 032-201, the current facility is approved for eight (8) omni antennas mounted to the building rooftop at a height of 31'-4" above BLACK & VEATCH Building a World of difference: grade. It does not appear that the approved modifications were installed. The existing facility consist of a total six (6) omni antennas. All associated electronics and cables are located inside a leased equipment room measuring approximately 154" x 20' on the first floor of the office building. With respect to land use, the site is currently used for mix -use commercial (office) and a Building - Mounted Cellular Telephone Antenna Facility. Uses surrounding this property are predominately commercial in nature. The subject property and much of the surrounding parcels are zoned B-2 and within the Aspen Business Center development. Other parcels surrounding this property are zoned a mix of I, PUB and AR -10 within the County and SCI, R/MF and C within the City of Aspen. It should be noted that there are other rooftop antenna installations, similar in design, within the Aspen Business Center, City of Aspen, and Pitkin County. A review of this existing facility and the proposed upgrades as they conform to the adopted approval standards for One -Step Review, Special Review Uses, Cellular Telephone Facilities, and the County Land Use Application Manual has been provided as part of this application. The existing wireless communications facility and proposed upgrades will not adversely impact the surrounding land. The Verizon Wireless facility has been carefully designed to blend in with the site and surrounding area. The location of the facility was chosen to ensure that the greatest amount of buffer has been provided from the abutting land uses, public rights-of-way and view corridors when the site was originally approved by the County in 2002 and continues to be the case today. The existing and proposed antennas are located approximately 4 feet from the edge of the building parapet, to reduce the visual impact from the ground. The proposed antennas will be painted brown to blend in with the roofline of the building. Because it is an unmanned facility with no water or sewer needs, there will continue to be no negative impacts to the County's infrastructure. This site is typically visited by either one or two technicians once or twice a month for routine monitoring and maintenance unless there are outages that require immediate attention. All Verizon Wireless sites are secure with restricted access. All sites also have alarm systems that alert a 24-hour Verizon Wireless monitoring office if there are any issues or concerns. In the case of an emergency Verizon's NOC can be reached at 1-800-264-6620 Verizon Wireless and this facility will continue to comply with all FCC rules governing construction requirements, technical standards, interference protection, power and height limitations, radio frequency standards and Radio Frequency Radiation (RFR) emission levels with continual and regular monitoring as well as FAA rules of location and operation. All permits necessary for the proposed antenna and equipment modifications will be obtained prior to commencement of the enhanced AWS LTE/4G service if approved by the County. Site History (BoCC Resolution No. 113-2002 & 012-2012) Verizon Wireless originally received approval by the BOCC on June 26, 2002, through a Special Use review. The original approval was limited to four (4) omni/whip antennas up to a height of 28 feet. In 2012 Pitkin Board of County Commissioners approved Resolution No 12-2012, allowing for a modification to Verizon's existing Site Plans. The modification increased the number of omni antennas from 4 to 6. The overall height of the building and upgraded antennas were approved at 31'-6". This modification was completed per the approved specs. Subsequently, In 2014 the BOCC approved Resolution No 032. The modification consisted of; increasing the number of omni antennas from 6 to 8. The proposed omni antennas were to be 7 feet in height. For an overall building height of 31'-4". It does not appear that the approved modifications were installed. The existing facility consist of a total six (6) omni antennas. L77] BLACK & VEATCH Building a World of difference: Coverage Objective Verizon Wireless is committed to serving its customers and the community as a whole by providing the optimum level of service. Verizon Wireless is mandated by the FCC to provide wireless communication services for the benefit of the public good which requires the development of communication sites to provide this service. Without this site, adequate service to the citizens and visitors of Pitkin cannot be maintained and would result in a significant gap in coverage. Updating the existing omni antennas to panels is essential to ensure adequate coverage is maintained. The increase demand on LTE/4G wireless service for smart phone, tablets, etc, is creating significant capacity needs causing additional sites to be constructed. Capacity is as much of a concern, if not more, as coverage given the significant use of smart phones, tablets, wireless internet devices, and other data intensive technologies given their high bandwidth requirements especially in dense residential and commercial areas such as this. Modification Design & Details Verizon Wireless is proposing to sectorize the site and add AWS/PCS technology to this site. This upgrade includes upgrading to panel antennas and installing new accessory equipment. Antennas will be mounted to a new ballast frame installed on the roof. The antennas have been stepped back approximately 4' from the edge of the parapet to reduce the visual impact from ground level. In 2014 the BOCC approved a total of eight (8) antennas at the site. The total number of antennas will not increase beyond eight (8). Remote Radio Heads and OVP (surge protectors) units will be located on a secondary frame located behind the antennas. Per the enclosed drawings, Verizon is proposing to make the following changes; • Two (2) existing CDMA omni antennas would remain in place (A2.20). • Remove four (4) existing omni antennas • Install six (6) new panel antennas. Antennas are six (6) feet in height. • Install a new 8'x8' ballast frame, on the north end of the rooftop to support the new antennas (A1.00). • Install twelve (12) new remote radio head (RRHs) on a secondary equipment frame. • Install one (1) new OVP (surge protector) on the secondary equipment frame. The new panel antennas will reach a height of 29'-6", below the currently approved height limit of the business center. All new equipment will be painted brown to blend in with the existing building. No exterior light is proposed in association with this modification. Please see attached Photo Sims. The Aspen Business Center has reviewed and approved this proposed antenna modification. The existing facility does not require anyone to be staffed on site. Typically, a technician will visit the site approximately once or twice a month to make sure the site is in proper working order and to perform routine maintenance. These visits generally last only a couple of hours. Space for parking has been provided for these visits and shown on the submitted drawings. This site was originally designed to support Verizon Wireless antennas and equipment and does not restrict additional carriers who wish to collocate on this rooftop as well. All utilities necessary for the existing facility run underground. Access comes from either Aspen Airport Business Center or American Drive via existing access drives and curb cuts. BLACK & VEATCH Building a World of difference: This site shall continue to comply with all standards and requirements as listed in the County's Land Use Code for granting Special Review approvals for modifications to existing building mounted facilities in the B-2 District per Section 2-30-30(h), Section 2 -40 -20a -c, Section 4-30-40(g) and Section 4-30-50(c). Summary As demonstrated above, the Verizon Wireless proposal shall continue to comply with all standards and requirements as listed in the County's Land Use Code for granting Special Review approvals/renewals for modifications to existing building mounted telecommunications facilities in the B-2 District per Section 2-30-30(h), Section 2 -40 -20a -c, Section 4-30-40(g) and Section 4-30- 50(c). The facility shall continue to be compatible with the site and surrounding area through careful design, color, site placement, minimal height and type of antennas used. L77] BLACK & VEATCH Building a World of difference: Pitkin County — Special Review for a Wireless Communications Facility 6/11/2018 Verizon Wireless - Sectorization (CO3 Aspen Airport) 301 Aspen Airport Business Center, Aspen Co 81611 Parcel #264334405053 Compliance with County Land Use Application Manual Section 1.1-1.8: Application Submission Requirements 1) General Application Information (Required for all Applications) 1.1 Applicant's Background Information A full background of the proposed application and applicant has been provided in this report. 1.2 Parcel Description & Vicinity Map A separate vicinity map and parcel description has been provided as part of this application. 1.3 Demonstration of Legal Creation and Disclosure/Proof of Ownership Verizon Wireless currently has an active lease with Mr. Craton Burkholder and Burkholder Investments, LTD. As required by Verizon Wireless' lease with Burkholder Investments, LTD, Mr. Burkholder's documented consent for the on-going operation of the facility and proposed antenna and equipment upgrades has been obtained. A copy of this signed letter dated 11/7/13 has been provided as part of this application. Further, the current County Assessor's information regarding this parcel has been provided showing that Burkholder Investments, LTD is still the property owner of record. 1.4 Legal Access Access currently comes from either Aspen Airport Business Center or American Drive via existing access drives and curb cuts. No new access is proposed at this time. 1.5 Standards Report A detailed project narrative has been provided that outlines how this application complies will all applicable County Land Use Code requirements and Application Manual. 1.6 Pre -Application Conference Summary Sheet A pre -application conference was held with Suzanne Wolff on 6/1/2018. A copy of the pre - application summary has been provided as part of this application. 1.7 Site Utilization Maps Verizon Wireless has complied with this requirement and provided all necessary maps of the appropriate size and quantity as specified in the pre -application summary. 1.8 Copies of Application The required number of copies of this application and supporting documents have been provided. Section 2.1.12: Site Plan, Review Process & Criteria for Approval Scenic View Protection Exhibits: This section describes the information and exhibits necessary to evaluate compliance with the Scenic View Protection standards contained in Section 7-20-120 of the Pitkin County Land Use Code. It was originally found by the County that the facility would have minimal impact, if any, on the scenic quality as the site is not readily visible from Hwy 82. The new panel antennas will reach a height of 29'-6'; below the currently approved height limit of the business center. All new equipment will be painted brown to blend in with the existing scenery. Please see attached Photo Sims. :4 1 r14 i :49rIAS forIN _ ��„" °v � rte, - _ a .. •.. venzonv CO3 Aspen Airport VIEW 2 - LOOKING NORTH EAST EXISTING CONDITIONS (This photo simulation is for illustrative purposes only) venzon CO3 Aspen Airport VIEW 2 - LOOKING NORTH EAST PROPOSED CONDITIONS (BROWN ANTENNAS) (This photo simulation is for illustrative purposes only) 0 venzon%' CO3 Aspen Airport VIEW 3 - LOOKING NORTH WEST EXISTING CONDITIONS (This photo simulation is for illustrative purposes only) verizonil CO3 Aspen Airport VIEW 3 - LOOKING NORTH WEST PROPOSED CONDITIONS (BROWN ANTENNAS) (This photo simulation is for illustrative purposes only) Genre► wo PS�n P►►p°rt 9 Aspen Caterers and Aspen Parly Rentals 4 Aspen Mini Storage 6 usine5s Centel 19 p peo f ►,%Vo Aspen Animal Hospital Aspen Costume & Tuxedo Rentals 19 Mi Hair Aspen Repair Service 4 Francesca's Empanadas Go gle 301 Aspen Airport Business Center Aspe BLACK & VEATCH Building a World of difference: Pitkin County — Special Review for a Wireless Communications Facility 6/11/2018 Verizon Wireless - Sectorization (CO3 Aspen Airport) 301 Aspen Airport Business Center, Aspen Co 81611 Parcel #264334405053 VICINITY MAP: 8Z :aloraec �� 3 Gollepr g_ �-'%�r '3 a �l. 9 'S 82 Gg�et �a �.o y� �e b X57 ��fl P` s N � As4'.'nPi:kin � � CP4�h AirpPn - b2 n �n l 1 1`r Black Te Ski Rentals of ft- ler Legal Description: Aspen Business Center Block 5, Lot 3, Filing1 J Site Location 5 Old Republic National Title Insurance Company CELL TOWER INFORMATION BINDER Order Number: 01-17084129-01T Policy Number: OX -12040990 Liability: $75,000.00 Fee: $1250.00 Subject to the exclusions from coverage, the limits of liability and other provisions of the Conditions and Stipulations hereto annexed and made a part of this Binder, OLD REPUBLIC NATIONAL TITLE INSURANCE COMPANY A Corporation, herein called the Company GUARANTEES BLACK & VEATCH CORPORATION" Herein called the Assured, against loss, not exceeding the liability amount stated above, which the assured shall sustain by reason of any incorrectness in the assurance which the Company hereby gives that, according to the public records as of 10/31/2017 1. Title to said estate or interest at the date hereof is vested in: BURKHOLDER INVESTMENTS, LTD 2. The estate or interest in the land hereinafter described or referred to covered by this Binder is: Fee Simple 3. The land referred to in this Binder is situated in the State of Colorado, County of PITKIN, described as follows: SITUATED IN THE COUNTY OF PITKIN, STATE OF COLORADO: BEING LOT 3, BLOCK 5, AMENDED AND RESTATED PLAT OF ASPEN AIRPORT BUSINESS CENTER FILING NO. 1, ACCORDING TO THE PLAT THEREOF FILED APRIL 16, 1979, IN PLAT BOOK 7 AT PAGE 79. 4. The following documents affect the land: (1) RESERVATIONS IN FAVOR OF THE UNITED STATES OF AMERICA AS SET FORTH IN THE DEED, RECORDED 06/02/1944, AS BOOK 167, PAGE 561 OF THE PITKIN COUNTY RECORDS. (2) DECREE FOR AN ADJUDICATION OF PRIORITY OF RIGHT OF USE OF WATER FROM MAROON CREEK FOR IRRIGATION AND OTHER BENEFICIAL PURPOSES, THROUGH THE STAPLETON BROTHERS, DITCH IN WATER DISTRICT NO. 38, RECORDED 09/26/1944, IN BOOK 167, PAGE 589 OF THE PITKIN COUNTY RECORDS. (3) SUBJECT TO EASEMENTS, AND RIGHTS OF WAY AS SHOWN ON THE PLAT OF ASPEN AIRPORT BUSINESS CENTER FILING NO. 1, AS RECORDED IN PLAT BOOK 4, PAGE 188 OF PITKIN COUNTY RECORDS. NOTE: FIRST AMENDMENT TO ASPEN AIRPORT BUSINESS CENTER FILING NO. 1 RECORDED 08/20/1974, AS BOOK 4, PAGE 478A OF THE PITKIN COUNTY RECORDS. NOTE: AMENDED AND RESTATED PLAT OF ASPEN AIRPORT BUSINESS CENTER FILING NO. 1 RECORDED 04/16/1979, AS BOOK 7, PAGE 79 OF THE PITKIN COUNTY RECORDS. Old Republic National Title Insurance Company CELL TOWER INFORMATION BINDER Order Number: 01-17084129-01T Policy Number: OX -12040990 NOTE: CONSENT AGREEMENT TO AMENDED AND RESTATED PLAT OF ASPEN AIRPORT BUSINESS CENTER FILING NO. 1 RECORDED 04/16/1979, AS BOOK 366, PAGE 627 OF THE PITKIN COUNTY RECORDS. NOTE: AMENDMENT TO CONSENT AGREEMENT TO AMENDED AND RESTATED PLAT OF ASPEN AIRPORT BUSINESS CENTER FILING NO. 1 RECORDED 11/26/1979, AS BOOK 379, PAGE 772 OF THE PITKIN COUNTY RECORDS. (4) DECLARATION OF PROTECTIVE COVENANTS FOR ASPEN AIRPORT BUSINESS CENTER, RECORDED 06/17/1971, IN BOOK 255, PAGE 916 OF THE PITKIN COUNTY RECORDS. (5) AVIGATION EASEMENT IN FAVOR OF PITKIN COUNTY, COLORADO, RECORDED 08/20/1974, AS BOOK 290, PAGE 373 OF THE PITKIN COUNTY RECORDS. (6) RESTRICTIONS AND CONDITIONS AS SET FORTH IN RESOLUTION NO. 113-2002, RECORDED 08/13/2002, IN DOCUMENT NO. 470913 OF THE PITKIN COUNTY RECORDS. (7) MEMORANDUM OF OPTION AND LEASE AGREEMENT BY AND BETWEEN BURKHOLDER INVESTMENTS, LTD., A COLORADO LIMITED PARTNERSHIP, LESSOR(S) AND COLORADO RSA NO. 3 LIMITED PARTNERSHIP, D/B/A VERIZON WIRELESS, LESSEE(S), RECORDED 03/08/2004 AS INSTRUMENT NO. 495251 OF THE PITKIN COUNTY RECORDS. (8) RESTRICTIONS AND CONDITIONS AS SET FORTH IN ADMINISTRATIVE DECISION NO. 69-2008, RECORDED 07/23/2008, IN DOCUMENT NO. 551308 OF THE PITKIN COUNTY RECORDS. (9) OCCUPANCY DEED RESTRICTION AND AGREEMENT FOR A CARETAKER DWELLING UNIT APPROVED PURSUANT TO SECTION 6-30-40(C) OF THE PITKIN COUNTY LAND USE CODE, RECORDED 08/18/2008, IN DOCUMENT NO. 552042 OF THE PITKIN COUNTY RECORDS. (10) RESTRICTIONS AND CONDITIONS AS SET FORTH IN BOCC RESOLUTION NO. 012-2012, RECORDED 02/24/2012, IN DOCUMENT NO. 586983 OF THE PITKIN COUNTY RECORDS. (11) RESTRICTIONS AND CONDITIONS AS SET FORTH IN BOCC RESOLUTION NO. 032-2014, RECORDED 03/24/2014, IN DOCUMENT NO. 608882 OF THE PITKIN COUNTY RECORDS. Nebel, Colleen To: 'Craton Burkholder' Subject: RE: Verizon's New Antennas for the Aspen Airport Business Center From: Nebel, Colleen Sent: Thursday, April 19, 2018 3:47 PM To: 'Craton Burkholder' <cratonb@comcast.net> Subject: RE: Verizon's New Antennas for the Aspen Airport Business Center Hi Craton, thank you for your time today. As we discussed, I will submit the current Site Plans to Mr. McBride for approval. Once approved by the business center, I will submit a zoning application through Pitkin County. I greatly appreciate your patience as we work through this process. Please don't hesitate to give me a call if you have any questions or concerns. Thank you, Colleen +1303-256-4079 P I Nebe1CkBV.com From: Craton Burkholder Imailto:cratonb(@comcast.net Sent: Monday, April 02, 2018 10:22 AM To: Nebel, Colleen <NebelC@bv.com> Subject: FW: Verizon's New Antennas for the Aspen Airport Business Center Subject: Verizon's New Antennas for the Aspen Airport Business Center The last plans are a nice thoughtful redesign. I appreciate your effort and have a few questions. 1) Do the three sector antennas emit any sound? - (They are above an apartment.) The antennas and accessory equipment do not emit any sound. 2) Antennas are relocated because? - Some of the original antennas are replaced and some removed? Correct, we are changing out the existing omni antennas and replacing them w/ panel antennas. This is a necessary equipment upgrade to provide AWS3 / PCS wireless service. - Location has better coverage? Correct. The new panel antennas need to see over the edge of the roof, in order to avoid interference (in layman terms, the signal needs to see over the roof, or it will bounce off and scatter). - Utilizing newer roof? Verizon's architect has completed a Structural Analysis to ensure that the new roof will support the additional weight. Verizon will also use your roofer to ensure that warranty is maintained. 3) Could new antennas be moved to south side of the drain? It would reduce the Animal Hospital parking lot visibility, etc. After some consider Verizon's RF engineer has determined that it would be detrimental to try and move the antennas any further away from the edge of the roof. 4) Verizon From: Rob Snyder To: Nebel, Colleen Subject: RE: Verizon Wireless (CO3 Aspen Airport - PCS/ Sectorization) Date: Wednesday, May 09, 2018 9:18:09 AM Colleen; John McBride, the declarant under the protective covenants for the Aspen Business Center has reviewed the photo shop renderings of what the new equipment on the Aspen Animal Hospital building and formally approves the installation of the new antennas. Thank you for generating these photos as it made visualizing what is planned quite easy and made granting an approval easy. Thank you- Rob Snyder Aspen Business Center Company From: Nebel, Colleen [mailto:NebelC@bv.com] Sent: Tuesday, May 08, 2018 12:38 PM To: Rob Snyder <rjsrsinc@comcast.net> Cc: Craton Burkholder <cratonb@comcast.net> Subject: RE: Verizon Wireless (CO3 Aspen Airport - PCS/ Sectorization) Rob, as requested our team has completed additional photo Sims of the proposed installation. I think you'll find that the proposed antennas blend in well with the sounding pine trees. Please see attached. Again, the upgrade from omni antennas to panel antennas is necessary to ensure Verizon is able to maintain adequate service. We are seeking consent from the Airport Business Center to the proposed Site Plans. Once received, I will be submitting a zoning application with Pitkin County. Please don't hesitate to give me a call if you have any questions or concerns. Thank you, Colleen +1303-256-4079 P I NebelCABV.com From: Rob Snyder [mail to:rjsrsincPcomcast.net] Sent: Thursday, April 26, 2018 9:31 AM To: Nebel, Colleen <NebelCna bv.com> Subject: RE: Verizon Wireless (CO3 Aspen Airport - PCS/ Sectorization) Colleen; John and I looked at the plans you sent us and he asked if we could get a photo from the north side, east side and south side of the building with the equipment photo shopped into the photo so we can really see what this is going to look like when the equipment is installed. The drawing we looked at that gave us the best indication of what this is going to look like was A3.00. That would really help in our review process. Thank you - Rob From: Nebel, Colleen [mailto:NebelCPbv.com] LETTER OF AUTHORIZATION To Whom It May Concern; jr�Lonw reies Vbeh9R 11rddiffiA NchMrk Deparbbea[ 3131 South Vaughn Way. Sm. 550 Aumm. CO 900+a Verizon Wireless hereby authorizes Black & Veatch Corporatian, its attorney's, agents, consultants, contractors or representatives to represent Verizon Wireless in real estate transactions and make any necessary zoning petitions including the filing of building permit applications - #?V I - Ae> q - Matt Butler Date Ve izon t fireless Real Estate & Regulatory Manager—Mountain Region Sworn to before me this- 'ef stay of An -,u, 2015_ Notary Public: BRAIDLEY&JOHNSON NOTARY PUBLIC STATE OF COLORADO My Commis5ivn Expires; I� r NOTARY la 20MOO4577 My COMMISSION EXPMES JUNE 09, 2017 > ir � � ■ § S FO @ . { � I w . g n gg m CL . g I � 0 \ \o> m -0 aD -Q1 - m \j32 - ¥ \ �E»§ EE[g o \C �\ § �Qlg §))k [7f / v` 2t 7 [§\ /CD§ z y% . .. z / \ CD 13130 2/ƒ / 0 m � 2 k - � . , - E o ) ` , 0 i \ \ / \ - { ƒ [ ^ \ 0 v 0 \ } } $ - § 0 , � _ � MCBRIDE JOHN P MCBRIDE JOHN P DALLMAN JACQUELYN S PO BOX 10493 303 E AABC PO BOX 70 ASPEN, CO 81612 ASPEN, CO 81611 CARBONDALE, CO 81623 DALLMAN JAMES DDABC LLC AABC 210 OWNERS LLC 534 DIAMOND A RANCH RD 15700 PARKERHOUSE RD #200 210 AABC #AA CARBONDALE, CO 81623 PARKER, CO 801349630 ASPEN, CO 81611-3513 MCBRIDE KATHERINE HAWLEY MCBRIDE KATHERINE HAWLEY MCBRIDE KATHERINE HAWLEY 303 E AABC 303 E AABC 303 E AABC ASPEN, CO 81611 ASPEN, CO 81611 ASPEN, CO 81611 JONES PAUL MCBRIDE KATHERINE HAWLEY TKG HOLDINGS LLC PO BOX 74 303 E AABC 214 AABC WOODY CREEK, CO 81656 ASPEN, CO 81611 ASPEN, CO 81611 TORNARE FELIX A & SARAH B CHILL LLLP TCI OF NORTH NEW JERSEY INC 5000 COUNTY RD 100 761 KALAMATH ST ONE COMCAST CENTER 32ND FL CARBONDALE, CO 81623-8862 DENVER, CO 80204 PHILADELPHIA, PA 19103 TCI OF NORTH NEW JERSEY INC ASPEN MINI STORAGE LLC PAM LLC ONE COMCAST CENTER 32ND FL 105 WOODWARD LN 208 AABC PHILADELPHIA, PA 19103 ASPEN, CO 81611 ASPEN, CO 81611 DANCE PROGRESSIONS LLC BUILDING 300 LLC MCBRIDE KATHERINE HAWLEY 403 ABC PO BOX 10493 303 E AABC ASPEN, CO 81611 ASPEN, CO 81612 ASPEN, CO 81611 MCBRIDE KATHERINE HAWLEY MCBRIDE JOHN P MCBRIDE JOHN P 303 E AABC 303 E AABC 303 E AABC ASPEN, CO 81611 ASPEN, CO 81611 ASPEN, CO 81611 HY-MOUNTAIN TRANSPORT INC FRONT AND CENTER LLC ANNIE MITCHELL HOMESTEAD HOA 214 B AABC 142 MAROON DR PO BOX 3149 ASPEN, CO 81611 ASPEN, CO 81611 ASPEN, CO 81612 PLETCHER EVAN GATES MICHAEL D CONARD M BRYAN 101 PASS GO LN #101 PO BOX 9143 PO BOX 9996 ASPEN, CO 81611 ASPEN, CO 81612 ASPEN, CO 81612 HOULIHAN SARA B DECARLO KIM VU TRUC K & TERESITA S 110 PASS GO LN PO BOX 9301 112 PASS GO LN ASPEN, CO 81611 ASPEN, CO 81612 ASPEN, CO 81611 HOWE PAUL BARSTOW JON F GASPERETTI JOHN 210 PASS GO LN 211 PASS GO LN 212 PASS GO LN ASPEN, CO 81611 ASPEN, CO 81611 ASPEN, CO 81611 HAAS JANET A CARROLAN SUSAN M MELTON LILY 220 PASS GO LN #220 PO BOX 206 310 PASS GO LN ASPEN, CO 81611 WOODY CREEK, CO 81656 ASPEN, CO 81611 SMITH ANDREW MARSH KAMALA LATHAM RYAN 311 PASS GO LN PO BOX 507 320 PASS GO LN ASPEN, CO 81611 ASPEN, CO 81612 ASPEN, CO 81611 MARX NICOLE E HOWELLS THOMAS HULSLANDER BRADFORD J & XIMENA 320 PASS GO LN 321 PASS GO LN 322 PASS GO LN # 322 ASPEN, CO 81611 ASPEN, CO 81611 ASPEN, CO 81611 GIAMPAOLO JOSEPH F JR WALKIEWICZ LAUREN L RUTLEDGE WILLIAM 0 IV PO BOX 7871 411 PASS GO LN #411 412 PASS GO LN ASPEN, CO 81612 ASPEN, CO 81611 ASPEN, CO 81611 DELAY JOHN P LIDDINGTON JENNIFER LYNK HARRY A II 420 PASS GO LN 421 PASS GO 510 PASS GO LN ASPEN, CO 81611 ASPEN, CO 81611 ASPEN, CO 81611 NAIBI MARIAM M ARIEL KYLE BARROW DAVID J 511 PASS GO LN 512 PASS GO LN 520 PASS GO LN ASPEN, CO 81611 ASPEN, CO 81611 ASPEN, CO 81611 FREEMAN PERRIN N III FULLER T NICOLE JAHN MARCIA L 521 PASS GO LN 522 PASS GO LN #522 610 PASS GO LN ASPEN, CO 816113421 ASPEN, CO 81611 ASPEN, CO 81611 REISCHE ERIC M RUTISHAUSER SANDRA KEANAAINA FARRAH K 611 PASS GO LN 611 PASS GO LN 612 PASS GO LN #612 ASPEN, CO 81611 ASPEN, CO 81611 ASPEN, CO 81611 NERBONNE ARTHUR R NORLUND KAREN L CASEY WILLIAM D 620 PASS GO LN 621 PASS GO LN 710 PASS GO LN #710 ASPEN, CO 81611 ASPEN, CO 81611 ASPEN, CO 81611 JOHNSON JEREMY R SMALL JACK E MONRONEY MICHAEL 711 PASS GO LN # 711 712 PASS GO LN 720 PASS GO LN ASPEN, CO 81611 ASPEN, CO 81611 ASPEN, CO 81611 DITTMAR GERMAN LEE JOEL D COLUMBINE STORAGE CTR INC 721 PASS GO 722 PASS GO LN #722 98 TOTTERDOWN RD ASPEN, CO 81611 ASPEN, CO 81611 ASPEN, CO 81611 ASPEN BUSINESS PARK INVESTORS LLC 583 HOLLAND HILLS DR BASALT, CO 81621 PITKIN COUNTY PRE -APPLICATION CONFERENCE SUMMARY PROJECT: Burkholder Investments LTD/Verizon Wireless Equipment Upgrade on Existing Building LOCATION: 301 AABC, AABC Block 5, Lot 3, Filing 1 PID# 264334405053 ZONE: B-2 OWNER: Burkholder Investments LTD REPRESENTATIVE: Colleen Nebel PHONE: 303-256-4079 EMAIL: NebelC@BV.com DATE: 6/1/18 PLANNER: Suzanne Wolff 970-920-5093 Type of Application: Special Review for a Wireless Communication Facility Description of Project/Development: The Applicant is requesting a Special Review to upgrade and expand the existing wireless antennas. • Two (2) CDMA omni antennas would remain in place (A2.20). • Install six (6) new panel antennas. Antennas are six (6) feet in height. • Install a new 8'x8' ballast frame, on the north end of the rooftop to support the new antennas (A1.00). • Install twelve (12) new remote radio head (RRHs) behind the antennas. • Install One (1) new OVP (surge protector) on the antenna frame. Background: BOCC granted Special Review approval for cellular/wireless facilities, pursuant to Resolution Nos. 113-2002, 012-2012 and 032-2014. The 2012 and 2014 modifications were not completed. Land Use Code Sections to be addressed in letter of reauest (aaDlication): Sec. 2-30-30(h): Special Review Criteria Sec. 2 -40 -20(a -c): Special Review Use Sec. 4-30-40(g): Wireless Communication Facility Sec. 4-30-50(d): Building Mounted Cellular Telephone Antennae Staff will refer the application to the following agencies: AABC, Aspen Fire Protection District Review by: BOCC Public Hearing? Yes, at BOCC. The Applicant shall post a public notice sign on the property at least 15 days prior to the date specified for the Administrative Decision pursuant to Sec. 2-20- 100(a)(3) of the Land Use Code. In addition, the Applicant shall mail notice (by first class mail) to all adjacent property owners within 300' of all property lines with the return address of the Community Development Department (form of notice to be obtained from the Community Development Department). The names and addresses shall be those on the current tax records of Pitkin County, as they appear no more than 60 days prior to the date of the public hearing. FEES: Total $2,054 (Please make check payable to "Pitkin County Treasurer") ■ Planning Office flat fee: $1,625 (non-refundable; based on 5 hours of staff time for review); if staff review time exceeds 6 hours, the Applicant will be charged for additional time above 5 hours at a rate of $325/hour) ■ $54 Public Notice Fee ■ $375 BOCC Clerk Fee To apply, submit 1 unbound and one-sided copy of the following information. Also provide all documents in PDF format as one combined file on a flash drive or email to plan ningapps(a)-pitkincounty.com. 1. Summary letter explaining the request, providing background on prior approvals and permits, and addressing each of the provisions of the Pitkin County Land Use Code identified above in sufficient detail to demonstrate that all substantive review criteria have been met. Summarize existing conditions, current uses and proposed futures uses or expansions as described in Section 1.1 through 1.8 of the Pitkin County Land Use Application Manual; 2. 24" by 36" and 11" by 17" site plan as designated in Section 2.1.12 of the Pitkin County Land Use Application Manual; 3. Special Review Uses submission requirements, standards report items and drawing requirements pursuant to Section 2.2.11 of the Pitkin County Land Use Application Manual, if not already addressed in 1 and 2 above including maintenance visits, emergency contact provisions, and FCC compliance for Radio Frequency Radiation (RFR) emission levels; 4. Scenic View Protection Exhibits as designated in Section 2.1.12 of the Pitkin County Land Use Application Manual; 5. Parcel description, including legal description and 8-1/2" x 11" vicinity map locating the subject property within Pitkin County; 6. Copies of all resolutions, ordinances and approvals including any recorded drawings for the parcel (as applicable); 7. Disclosure and proof of ownership of the property, consisting of a current certificate from a title insurance company or attorney licensed to practice law in the State of Colorado, listing the names of all owners of the property and all mortgagees, judgments, liens, easements, contracts and agreements affecting use and development of the parcel and proof of the owner's right to use the land for the purposes identified in the development application. 8. Consent from all owners to process application and authorizing the representative; 9. List of all property owners within a 300' radius of the all property lines; 10. Total fee for review of the application; 11. Executed Pitkin County Community Development Agreement for Payment of Land Use Application Fees Agreement (form attached); 12. Copy of this Pre -application Conference Summary form NOTES: ➢ PLEASE INCLUDE THE PARCEL ID NUMBER ON ALL DOCUMENTS INCLUDED IN YOUR APPLICATION. ➢ ALL MAPS SHALL BE FOLDED. ➢ This pre -application conference summary is advisory in nature and not binding on the County. The information provided in this summary is based on current zoning standards and staff's interpretations based upon representations of the applicant. Additional information may be required upon a complete review of the application. ➢ The Land Use Code is available on-line at http://pitkincounty.com/468/County-Code. ➢ The Land Use Application manual is available on-line at http://pitkincounty.com/196/Land-Use ➢ Applicant will be responsible for mailed and posted notice. Public Notice requirements are described in Section 2-20-100 of the Pitkin County Land Use Code. A signed, notarized copy of the affidavit confirming notice must be received from Applicant prior to approval. z z w 2 w Q Q � w Qz W Z U) ~ J W z z w 'm Z W W U) a w U W J J U) Z �o a(D (7 z 0 z OW O . O (� w w W a3� O a O w Df w m u- 0f �m LL w w J m U O O 2 06 o' D m m >- m 11 x verizon%I EXISTING CONDITIONS PROJECT DESCRIPTION REMOVE (4) EXISTING VERIZON WIRELESS OMNI ANTENNAS NEW BALLASTED ANTENNA FRAME WITH (6) 6'H VERIZON WIRELESS ANTENNAS NEW BALLASTED FRAME WITH RF EQUIPMENT ON (E) ROOF (2) NEW 6X12 HYBRID CABLES ROUTED FROM (E) VERIZON WIRELESS EQUIPMENT ROOM TO ANTENNAS NEW ROOFTOP CABLE TRAY REPLACE PDF IN VERIZON WIRELESS EQUIPMENT ROOM NEW D -RING ON ROOF I�:za�x.���x�►•� OWNER BURKHOLDER INVESTMENTS, LTD ATTN: CRATON BURKHOLDER 1596 W. BUTTERMILK ROAD ASPEN. CO 81611 CLIENT RF ENGINEER VERIZON WIRELESS VERIZON WIRELESS MIKE HICKEY BRYAN EICENS CONSTRUCTION ENGINEER 3131 S. VAUGHN WAY 3131 S. VAUGHN WAY SUITE 550 SUITE 550 AURORA, CO 80014 AURORA CO, 80014 PHONE: 617.835.2690 PHONE: 951.413.9704 2 �a SITE ACQUISITIONIST BLACK & VETCH CORP. COLLEEN NEBEL 4600 S. SYRACUSE STREET SUITE 800 DENVER,CO 80237 PHONE:720.834.4362 14 ARCHITECT CSAi CHARLES STECKLY,AIA 5935 S. ZANG STREET SUITE 280 LITTLETON, CO 80127 CELL: 303.210.8972 OFFICE: 303.932.9974 SITE NAME: CO3 ASPEN AIRPORT PROJECT SMR - SECTORIZATION/PCS ADD SITE I.D.#: 264 PROJECT #: 20171640169 LOCATION #: 120049 SITE ADDRESS: 301 ASPEN AIRPORT BUSINESS CENTER G1.00 ASPEN, CO 81611 VICINITY MAP LS1 DRAWING INDEX PROJECT DATA JURISDICTION SHEET DESCRIPTION ASPEN AIRPORT BUSINESS ZONING DESIGNATION B-2 CENTER (36 MILES) T 1.00 TITLE SHEET SAGE WAY G1.00 GENERAL NOTES FULLY SPRINKLERED LS1 TOPOGRAPHIC SURVEY 2 LS2 TOPOGRAPHIC SURVEY OF SITE B, INCIDENTAL USE CONSTRUCTION TYPE FORK A1.00 SITE PLAN AND HYBRID CABLE DIAGRAM �O A2.00 EQUIPMENT ROOM FLOOR PLAN OOSA�/ FORK A2.10 EQUIPMENT ROOM RCP tiG A2.20 OMNI ANTENNA PLANS S A2.30 NEW ANTENNA PLAN AND DETAILS A3.00 ELEVATIONS ASPEN AIRPORT A4.00 DETAILS BUSINESS CENTER A5.00 RACK ELEVATION 82 A6.00 GROUNDING SCHEMATIC N NOT TO SCALE DIRECTIONS ATTACHMENTS FROM DENVER, CO 1-70W (147 MILES) EXIT 116 FOR GLENWOOD SPRINGS STRUCTURAL ANALYSIS RIGHT ON CO -82 (0.1 MILES) BY: OTEGUI STRUCTURAL SERVICES RIGHT ONTO 6TH ST (0.1 MILES) DATED: 01/05/18 RIGHT ON GRAND AVE./CO-82 (0.2 MILES) LEFT ONTO ASPEN AIRPORT BUSINESS CENTER (36 MILES) RIGHT ONTO SAGE WAY (50 FT) RIGHT AT FORK FOR ON ASPEN AIRPORT BUSINESS CENTER (25 MI) LEFT AT FORK TO STAY ON ASPEN AIRPORT BUSINESS CENTER SITE IS ON LEFT (0.2 MILES) PROJECT DATA JURISDICTION PITKIN COUNTY APN 2643-344-05-053 ZONING DESIGNATION B-2 EXISTING BUILDING TEMPE, AZ 85281 OCCUPANCY GROUP B CONSTRUCTION TYPE II -B FULLY SPRINKLERED NO NO. STORIES 2 EQUIPMENT ROOM OCCUPANCY GROUP B, INCIDENTAL USE CONSTRUCTION TYPE II -B FULLY SPRINKLERED NO NO. STORIES 1 GOVERNING CODES: 2015 IBC, 2015 IFC, 2015 IMC, 2014 NEC A.D.A. COMPLIANCE THIS FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION STRUCTURAL SURVEYOR OTEGUI STRUCTURAL RLE CONSULTING SERVICES,LLC 1214 N. STADEM DR. MICHAEL OTEGUI TEMPE, AZ 85281 8842 WEST POWERS PLACE PHONE: 480.445.9189 LITTLETON, CO 80123 PHONE: 720.981.5333 veria®nv' VERIZON WIRELESS SERVICES 3131 S. VAUGHN WAY, SUITE 550 AURORA, CO 80014 PROJECT INFORMATION SITE NAME CO3 ASPEN AIRPORT SITE I.D. 264 301 ASPEN AIRPORT BUSINESS CENTER ASPEN, CO 81611 CONSULTANT A 10/30/17 CONCEPT RSS B 11/06/17 RF COMMENTS RSS C 01/05/18 CLIENT COMMENTS RSS D 02/05/18 L.L. COMMENTS RSS E 03/01/18 CLIENT COMMENTS RSS 1st REVIEW SSB 2nd REVIEW KMS 5935 SOUTH ZANG STREET, SUITE 280 LITTLETON, COLORADO 80127 OFFICE: 303.932.9974 NOT FOR CONSTRUCTION TITLE SHEET T1.00 U) z O w z w o_ U) z z w z Z z z w w � w ¢z w z m ~ J W I - z w Z W z w W J F U) U) 00 U Z ¢ (W7 C7 z zz Lu 0 J LU w O d O III w m u- Ir �m LL 11 U) J m U 0 O U od � o tY � Z) m m > m11x ABBREVIATIONS @ AT H.M. HOLLOW METAL CL CENTERLINE HORZ. HORIZONTAL ° DEGREES HR. HOUR 0 DIAMETER HT. HEIGHT A/C AIR CONDITIONER ILC INTEGRATED LOAD CENTER APPROX. APPROXIMATE INT. INTERIOR ARCH. ARCHITECTURAL A.F.F. ABOVE FINISH FLOOR L.F. LINEAR FEET A.F.G. ABOVE FINISH GRADE LTE LIMIT TO EXTEND ALU ALCATEL LUCENT SS (E) SANITARY SEWER ATS AUTOMATIC TRANSFER SWITCH MAX. MAXIMUM AWS ADVANCED WIRELESS SYSTEM MECH. MECHANICAL FIBER (E) FIBER CABLE MFR. MANUFACTURER BBU BASE BAND UNIT MGB MAIN GROUND BAR BCEM BASE CHANNEL ELEMENT MIN. MINIMUM MODULE MSDS MATERIAL SAFETY DATA SHEET BLDG. BUILDING MTL. METAL B.O. BOTTOM OF MTS MANUAL TRANSFER SWITCH CLG. CEILING N.T.S. NOT TO SCALE COL. COLUMN CONC. CONCRETE O.C. ON CENTER O.D. OUTSIDE DIAMETER DBL. DOUBLE OVP OVER VOLTAGE PROTECTION DIA. DIAMETER DIM. DIMENSION PCS PERSONAL COMMUNICATIONS DISC. DISCONNECT SERVICE DN. DOWN DWG. DRAWING RAD. RADIUS R.O. ROUGH OPENING (E) EXISTING RRH REMOTE RADIO HEAD EA. EACH ELEV. ELEVATION SHTG. SHEATHING ELEC. ELECTRICAL SIM. SIMILAR EQ. EQUAL SPEC. SPECIFICATION EXT. EXTERIOR S.S. STAINLESS STEEL STL. STEEL F.E. FIRE EXTINGUISHER STRUCT. STRUCTURAL FIN. FINISH FLR. FLOOR T.C. TEMPERATURE CONTROL FUT. FUTURE TELCO TELECOMMUNICATIONS T.O. TOP OF GA. GAUGE TYP. TYPICAL GALV. GALVANIZED GEN. GENERATOR U.G. UNDERGROUND GPS GLOBAL POSITIONING SYSTEM U.N.O. UNLESS NOTED OTHERWISE GWB. GYPSUM WALLBOARD VERT. VERTICAL V.I.F. VERIFY IN FIELD W/ WITH SYMBOLS LEGEND — — — — — — — EASEMENT X ENLARGED VIEW LEASE LINE �_ — — PROPERTY LINE n n FENCE ELEVATION WOODEN MARKER X CHAIN LINK FENCE SPOT OH (E) OVERHEAD UTILITY ELEVATION OHE (E) OVERHEAD ELEC. X SECTION CUT SS (E) SANITARY SEWER W (E) WATER LINE X T (E) TELCO CABLE XX, EXTERIOR ELEVATION FIBER (E) FIBER CABLE E (E) ELECTRICAL INTERIOR ELEVATION COAX (E) COAX CABLE 0 REVISION NUMBER GENERAL CONSTRUCTION SOW HYBRID & COAX CABLES DC POWER FIBER ANTENNAS RRH/BBU PENETRATIONS —14 5 - ABBREVIATIONS, SYMBOLS AND LEGEND 1. GENERAL: PROVIDE ALL LABOR, EQUIPMENT AND MATERIALS NECESSARY FOR RECEIVING, INSTALLING, TESTING AND ADJUSTING ANTENNA CABLES FROM THE ANTENNA TO THE CONNECTORS AT THE BASE TRANSMISSION SYSTEM (BTS). THIS SHALL INCLUDE ALL EQUIPMENT SHOWN OR REQUIRED FOR A COMPLETE OPERATING SYSTEM. ANTENNA, ANTENNA CABLES, CONNECTORS, AND FITTINGS SHALL BE THIRD PARTY FURNISHED COMPONENTS AS SHOWN ON THE BILL OF MATERIALS. 2. MATERIALS: A. RE: HYBRID CABLE DIAGRAM FOR ADDITIONAL INFORMATION B. CABLE HANGERS: INSTALLED AT MAXIMUM 4' SPACING C. GROUND EQUIPMENT PER VERIZON WIRELESS SPECS 3. INSTALLATION: A. ANTENNA CABLE LENGTHS SHALL BE FIELD MEASURED PRIOR TO PURCHASE OF CABLE. INSTALLER SHALL NOTIFY VERIZON WIRELESS OF THE OVERALL LENGTH REQUIRED. B. CABLES SHALL BE LABELED IN ACCORDANCE WITH VERIZON WIRELESS SPECIFICATIONS. C. ALL OUTSIDE CABLE CONNECTIONS SHALL BE COVERED WITH WEATHERPROOFING TAPE. D. THE MINIMUM BENDING RADIUS FOR ALL ANTENNA CABLES SHALL BE AS SHOWN BELOW OR AS PER THE MANUFACTURER, WHICHEVER IS MORE CONSERVATIVE: ANTENNAS CABLE IN AIR/ CABLE TRAY IN CONDUIT 1/2" 5" 10" 7/8" 10" 18" 15/8" 20" 28" 1X1 HYBRID 5" 10" 6X12 HYBRID 12" 16" MW CABLE WITHOUT REBENDING WITH REBENDING ELEIPTICAL 6" E PLAN 7" E PLAN WAVEGUIDE 13" H PLAN 19" H PLAN E. CABLES SHALL BE INSTALLED WITH THE MINIMUM NUMBER OF BENDS. CABLES SHALL NOT BE LEFT UNTERMINATED IN THE FIELD. F. GROUNDING KITS - AFTER INSTALLATION OF GROUND STRAPS, THE CONNECTION SHALL BE MADE WEATHER TIGHT USING WEATHERPROOFING KITS AS IDENTIFIED ABOVE. GROUND PIGTAILS SHALL BE BROUGHT OUT IN THE DOWNWARD DIRECTION FROM THE CONNECTIONS TO THE ANTENNA CABLE WITHOUT ANY SHARP BENDS (MINIMUM BEND RADIUS 10") AND CONNECTION SHALL BE MADE TO GROUNDING SYSTEM 4 - ANTENNA NOTES AND REQUIREMENTS BATTERY SPECIFICATION: (C&D TRUE TEL 12-180F) EACH CELL HAS AN IMMOBILIZE ELECTROLYTE CAPACITY OF 0.4 GALLONS EACH. (48) CELLS IN THIS OCCUPANCY RESULTING IN AN AGGREGATE ELECTROLYTE VOLUME OF 19.2 GALLONS. A. STATIONARY LEAD -ACID BATTERY SYSTEM AND VALVE -REGULATED LEAD -ACID BATTERY SYSTEMS CONTAINING MORE THAN 50 GALLONS OF ELECTROLYTE SHALL COMPLY WITH IFC 608. THIS INSTALLATION IS BELOW 50 GALLONS. CONTRACTOR TO PROVIDE HAZMAT REPORTING & ADDITIONAL PERMITS FOR BATTERY & GENERATOR SYSTEMS PER LOCAL REQUIREMENTS 3 - BATTERY HAZMAT REVIEW CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTING DIMENSIONS AND CONDITIONS ON THE JOB SITE AND SHALL IMMEDIATELY NOTIFY THE ARCHITECT IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME THESE DRAWINGS ARE TO SCALE WHEN PLOTTED ON 11X17 SHEET CALL BEFORE YOU DIG - COLORADO LAW REQUIRES 3 WORKING DAYS NOTICE FOR CONSTRUCTION PHASE. THESE DRAWINGS MAY NOT SHOW ALL UNDERGROUND PIPING AND UTILITIES. THE CONTRACTOR SHALL EXERCISE EXTREME CARE DURING ALL EXCAVATION AND OTHER CONSTRUCTION ACTIVITIES. UTILITY NOTIFICATION CENTER OF COLORADO - 1-800-922-1987 THE CONTRACTOR IS RESPONSIBLE FOR ALL UTILITY LOCATES AND UTILITY RELOCATIONS REQUIRED FOR THIS INSTALLATION. THE CONTRACTOR W ILL SCHEDULE AND COORDINATE ALL WORK WITH THE OWNER TO ENSURE NO DISRUPTION TO OWNERS OPERATIONS. SUBCONTRACTORS SHALL VERIFY ALL PLANS & EXISTING DIMENSIONS & CONDITIONS ON THE JOB SITE & SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME 2 - GENERAL CONTRACTOR NOTES 1. DRAWINGS ARE NOT TO BE SCALED, WRITTEN DIMENSIONS TAKE PRECEDENCE, AND THIS SET OF PLANS IS INTENDED TO BE USED FOR DIAGRAMMATIC PURPOSES ONLY, UNLESS NOTED OTHERWISE. THE GENERAL CONTRACTOR'S SCOPE OF WORK SHALL INCLUDE FURNISHING ALL MATERIALS, EQUIPMENT, LABOR, AND ANYTHING ELSE DEEMED NECESSARY TO COMPLETE INSTALLATIONS AS DESCRIBED HEREIN. REFER TO BID PACKAGE FOR MORE DATA. 2. PRIOR TO THE SUBMISSION OF BIDS, THE CONTRACTORS INVOLVED SHALL VISIT THE JOB SITE AND FAMILIARIZE THEMSELVES WITH ALL CONDITIONS AFFECTING THE PROPOSED PROJECT WITH THE CONSTRUCTION AND CONTRACT DOCUMENTS, FIELD CONDITIONS AND CONFIRM THAT THE PROJECT MAY BE ACCOMPLISHED AS SHOWN PRIOR TO PROCEEDING WITH CONSTRUCTION. ANY ERRORS, OMISSIONS, OR DISCREPANCIES ARE TO BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/CONSTRUCTION ENGINEER IN WRITING. 3. THE GENERAL CONTRACTOR SHALL RECEIVE WRITTEN AUTHORIZATION TO PROCEED WITH CONSTRUCTION PRIOR TO STARTING WORK ON ANY ITEM NOT CLEARLY DEFINED BY THE CONSTRUCTION DRAW INGS/CONTRACT DOCUMENTS. 4. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE PROJECT DESCRIBED HEREIN. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES AND FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT. 5. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS ACCORDING TO MANUFACTURER'S, VENDOR'S, & VERIZON WIRELESS SPECIFICATIONS UNLESS NOTED OTHERWISE OR WHERE LOCAL CODES OR ORDINANCES TAKE PRECEDENCE NOTIFY CONSTRUCTION ENGINEER. 6. ALL WORK PERFORMED ON PROJECT AND MATERIALS INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS, AND ORDINANCES. CONTRACTOR SHALL GIVE ALL NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY, MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS, AND LOCAL AND STATE JURISDICTIONAL CODES BEARING ON THE PERFORMANCE OF THE WORK. 7. THE STRUCTURAL COMPONENTS OF THIS PROJECT SITE/FACILITY ARE NOT TO BE ALTERED BY THIS CONSTRUCTION PROJECT UNLESS NOTED OTHERWISE. 8. NEW TOWERS ARE UNDER A SEPARATE CONTRACT. THE CONTRACTOR SHALL ASSIST ANTENNA INSTALLATION SUBCONTRACTOR IN TERMS OF COORDINATION AND SITE ACCESS. ERECTION SUBCONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTION OF PERSONNEL AND PROPERTY FROM HAZARDOUS EXPOSURE TO OVERHEAD DANGERS. 9. GENERAL CONTRACTOR SHALL PROVIDE AT THE PROJECT SITE A FULL SET OF PERMITTED CONSTRUCTION DOCUMENTS UPDATED WITH THE LATEST REVISIONS AND ADDENDA OR CLARIFICATIONS FOR THE USE BY ALL PERSONNEL INVOLVED WITH THE PROJECT. 10. DETAILS INCLUDED HEREIN ARE INTENDED TO SHOW END RESULT OF DESIGN. MINOR MODIFICATIONS MAY BE REQUIRED TO SUIT JOB CONDITIONS OR SITUATIONS, AND SUCH MODIFICATIONS SHALL BE INCLUDED AS PART OF THE SCOPE OF WORK. 11. THE FACILITY IS CELLULAR RADIO EQUIPMENT, ANTENNAS, & SUPPORTING UTILITIES. 12. THE CONTRACTOR SHALL MAKE NECESSARY PROVISIONS TO PROTECT EXISTING IMPROVEMENTS, EASEMENTS, PAVING, CURBING, ETC. DURING CONSTRUCTION UPON COMPLETION OF WORK. CONTRACTOR SHALL REPAIR ANY DAMAGE THAT MAY HAVE OCCURRED DUE TO CONSTRUCTION ON OR ABOUT THE PROPERTY. 13. CONTRACTOR SHALL ENSURE THE GENERAL WORK AREA IS KEPT CLEAN AND HAZARD FREE DURING CONSTRUCTION AND DISPOSE OF ALL DIRT, DEBRIS, RUBBISH AND REMOVE EQUIPMENT NOT SPECIFIED AS REMAINING ON THE PROPERTY, PREMISES SHALL BE LEFT IN CLEAN CONDITION AND FREE FROM PAINT SPOTS, DUST, OR SMUDGES OF ANY NATURE. 14. THE ARCHITECTS/ENGINEERS HAVE MADE EVERY EFFORT TO SET FORTH IN THE CONSTRUCTION AND CONTRACT DOCUMENTS THE COMPLETE SCOPE OF WORK. CONTRACTORS BIDDING THE JOB ARE NEVERTHELESS CAUTIONED THAT MINOR OMISSIONS OR ERRORS IN THE DRAWINGS AND OR SPECIFICATIONS SHALL NOT EXCUSE SAID CONTRACTOR FROM COMPLETING THE PROJECT AND IMPROVEMENTS IN ACCORDANCE WITH THE INTENT OF THESE DOCUMENTS. THE BIDDER SHALL BEAR THE RESPONSIBILITY OF NOTIFYING (IN WRITING) THE CONSTRUCTION ENGINEER OF ANY CONFLICTS, ERRORS, OR OMISSIONS PRIOR TO THE SUBMISSION OF CONTRACTOR'S PROPOSAL. 15. SPECIAL INSPECTION TESTING REQUIRING SPECIAL INSPECTIONS SHALL BE PERFORMED BY AN INDEPENDENT SPECIAL INSPECTOR PER SECTION 1704 OF THE INTERNATIONAL BUILDING CODE (IBC) FOR ITEMS NOTED ON S1.00 IF INCLUDED IN CONSTRUCTION DOCUMENTS. THE INSPECTOR SHALL BE HIRED BY THE CONTRACTOR & COORDINATION SHALL BE ARRANGED BY THE CONTRACTOR FOR REQUIRED INSPECTIONS. 1 - GENERAL NOTES UNDERGROUND SERVICE ALERT UTILITY NOTIFICATION CENTER OF COLORADO 1-800-922-1987 W W W.UNCC.ORG 3 WORKING DAYS UTILITY NOTIFICATION PRIOR TO CONSTRUCTION veria®nv' VERIZON WIRELESS SERVICES 3131 S. VAUGHN WAY, SUITE 550 AURORA, CO 80014 PROJECT INFORMATION SITE NAME CO3 ASPEN AIRPORT SITE I.D. 264 301 ASPEN AIRPORT BUSINESS CENTER ASPEN, CO 81611 CONSULTANT A 10/30/17 CONCEPT RSS B 11/06/17 RF COMMENTS RSS C 01/05/18 CLIENT COMMENTS RSS D 02/05/18 L.L. COMMENTS RSS E 03/01/18 CLIENT COMMENTS RSS 1st REVIEW SSB 2nd REVIEW KMS 5935 SOUTH ZANG STREET, SUITE 280 LITTLETON, COLORADO 80127 OFFICE: 303.932.9974 NOT FOR CONSTRUCTION GENERAL NOTES Gl .00 SURVEYOR NOTES 1. ALL TITLE INFORMATION IS BASED UPON A COMMITMENT FOR TITLE INSURANCE PREPARED BY OLD REPUBLIC TITLE INSURANCE COMPANY, ORDER NO.: 01-17084129-017 EFFECTIVE DATE: 10/31/2017. 2. SURVEYOR HAS NOT PERFORMED A SEARCH OF PUBLIC RECORDS TO DETERMINE ANY DEFECT IN TITLE. 3. THE BOUNDARY SHOWN HEREON IS PLOTTED FROM RECORD INFORMATION AND DOES NOT CONSTITUTE A BOUNDARY SURVEY OF THE PROPERTY. 4. SURVEYOR DOES NOT GUARANTEE THAT ALL UTILITIES ARE SHOWN OR THEIR LOCATIONS, IT IS THE RESPONSIBILITY OF THE CONTRACTOR AND DEVELOPER TO CONTACT BLUE STAKE AND ANY OTHER INVOLVED AGENCIES TO LOCATE ALL UTILITIES PRIOR TO CONSTRUCTION. REMOVAL, RELOCATION AND/ OR REPLACEMENT IS THE RESPONSIBILITY OF THE CONTRACTOR. PROJECT META DATA 1. ELEVATIONS SHOWN HEREON ARE REPRESENTED IN NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD88) ESTABLISHED FROM GPS DERIVED ELLIPSOID HEIGHTS, APPLYING GEOID 09 SEPARATIONS CONSTRAINING TO NGS CORS STATIONS PROVIDED IN THE "ONLINE POSITIONING USER SERVICE" (OPUS) SOLUTION FOR THIS SPECIFIC SITE. 2. BEARINGS SHOWED HEREON ARE BASED UPON U.S. STATE PLANE NAD83 COORDINATE SYSTEM COLORADO STATE PLANE COORDINATE ZONE CENTRAL, DETERMINED BY GPS OBSERVATIONS. 3. FIELD WORK FOR THIS PROJECT WAS PERFORMED ON 11/13/2017. FLOOD ZONE DESIGNATION THE PROPOSED LEASE PREMISES SHOWN HEREON APPEAR TO BE WITHIN FLOOD ZONE "X" AS DELINEATED ON THE FEDERAL EMERGENCY MANAGEMENT AGENCY FIRM MAP NO. 08097CO201C DATED 06/04/1987. FLOOD ZONE "X" IS DEFINED AS: AREAS DETERMINED TO BE OUTSIDE 500 -YEAR FLOODPLAIN; DETERMINED TO BE OUTSIDE THE 1% AND 0.2% ANNUAL CHANCE FLOODPLAINS. LESSOR'S LEGAL DESCRIPTION SITUATED IN THE COUNTY OF PITKIN, STATE OF COLORADO: BEING LOT 3, BLOCK 5, AMENDED AND RESTATED PLAT OF ASPEN AIRPORT BUSINESS CENTER FILING NO. 1, ACCORDING TO THE PLAT THEREOF FILED APRIL 16, 1979, IN PLAT BOOK 7 AT PAGE 79. SCHEDULE B EXCEPTIONS OSUBJECT TO EASEMENTS, AND RIGHTS OF WAV AS SHOWN ON THE PLAT OF ASPEN AIRPORT BUSINESS CENTER FILING NO. 1, AS RECORDED IN PLAT BOOK 4, PAGE 1 S8 OF PITKIN COUNTY RECORDS. NOTE: FIRST AMENDMENT TO ASPEN AIRPORT BUSINESS CENTER FILING NO. 1 RECORDED 08/20/1974, AS BOOK 4, PAGE 478A OF THE PITKIN COUNTY RECORDS. NOTE: AMENDED AND RESTATED PLAT OF ASPEN AIRPORT BUSINESS CENTER FILING NO. 1 RECORDED 04/16/1979, AS BOOK 7, PAGE 79 OF THE PITKIN COUNTY RECORDS. NOTE: CONSENT AGREEMENT TO AMENDED AND RESTATED PLAT OF ASPEN AIRPORT BUSINESS CENTER FILING NO. 1 RECORDED 04/16/1979, AS BOOK 366, PAGE 627 OF THE PITKIN COUNTY RECORDS. NOTE: AMENDMENT TO CONSENT AGREEMENT TO AMENDED AND RESTATED PLAT OF ASPEN AIRPORT BUSINESS CENTER FILING NO. 1 RECORDED 11 /26/1979, AS BOOK 379, PAGE 772 OF THE PITKIN COUNTY RECORDS. ITEMS 1, 2, AND 4 THRU 11 OF THE CLIENT PROVIDED TITLE REPORT DO NOT CONTAIN GRAPHICALLY PLOTTABLE EASEMENTS, SETBACKS, RESTRICTIONS OR OTHER ENCUMBRANCES. THE SURVEYOR CANNOT GUARANTEE THAT NON-PLOTTABLE ENCUMBRANCES DO NOT EXIST THAT MAY AFFECT THE SUBJECT LEASED PREMISES. R CENtE �p)RRrN 10NESs pSPEO�eI� N1'"9257 `•. _EO I � T ? ASPHALT PARKING Y/ LOT 1 1 1 1 NATURAL ` GROUND I 1 0 1 �m 1 Z 1 NO 1 aN - 1 ¢ o F 1 z 1 1 1 R=230.00 1 (E) BACK OF CURB Rry exy D ACFL 22580 ASPEN AIRPORT BUSINESS CENTER O(El 30' W W SAGEWAY PROJECTAREA 4 N.T.S. verizonJ 3131 S. VAUGHN WAY, SUITE 550 AURORA, CO 80014 LEGEND H-Alla"Im OO FOUND AS NOTED 0 AIR CONDITIONING UNIT • ELECTRIC METER • ELECTRIC SWITCH 0 ELECTRICAL TRANSFORMER © FIBER VAULT - . • o TELEPHONE PULL BOX POWER POLE c DOWN GUY FIELD BY: JWS Qo VENT RISER o VENT PIPE DRAWN BY: cRs s ROOF DRAIN ( ANTENNA CHECKED BY: ABTA © GAS METER Sb FIRE HYDRANT REVISIONS pQ WATER VALVE WATER METER BACKFLOW PREVENTER IRRIGATION CONTROL VALVE ® STORM DRAIN GRATE $ DECIDUOUS TREE BREAKLINE x 52WP NG SPOT ELEVATION 2 12/13/17 TITLE REVIEW AND FINAL POSITION OF GEODETIC COORDINATES 1 11/20/17 PRELIMINARY PROPERTY LINE NO. DATE DESCRIPTION PROPERTY LINE (OTHER) CENTERLINE O O CHAIN LINK FENCE OHE OHE OVERHEAD ELECTRIC LINE uGE UGE U/G ELECTRIC LINE T T T U/G TELECOMMUNICATION LINE —FO FO—FO— U/G FIBER OPTIC LINE , G G G U/G GAS LINE SD SD SD STORM SEWER LINE ,C APN ASSESSORS PARCEL NUMBER =NSLJ LT I N G ANT ANTENNA BLDG BUILDING �allo sunvEr . r.na��n.x3 ao�urior,s CS CONCRETE SURFACE �W H ST.4L1eM de • TEN7rE A= 9e29i D/W DRIVEWAY www.rxxwsU�rirv�.corn . �aaw•�aao FS FINISH SURFACE NG NATURAL GRADE OVH OVERHANG TOP PV ASPHALT SW SIDEWALK RIW RIGHT OF WAY SEE SURVEY DETAIL SHEET LS -2 DO L/CFS 38207 p 0 12/13/17 s��ONq L S r go 5. LA MAGNETIC NORTH DECLINATION GRAPHIC SCALE 20 0 10 20 40 80 ( IN FEET ) 1 inch = 20 It REUSE OF DOCUMENT THE IDEAS& DESIGN INCORPORATED HEREON, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF RLF CONSULTING, LLC & IS NOT TO BE USED FOR ANY OTHER PROJECT WITHOUT WRITTEN AUTHORIZATION OF RLF CONSULTING, LLC. PROJECT No. 15010134 SITE NAME: ASPEN AIRPORT SITE ADDRESS: 301 ASPEN AIRPORT BUSINESS CENTER ASPEN, CO 81611 SHEET TITLE: TOPOGRAPHIC SURVEY SHEET NO. REVISION: LS -1 I I I 77]8.8 EPI -A Al I 7718.3 N ASPHALT)_ / PARKING (E) 10' EASEMENT(3>_� �-- -}-r I 7776.5 EP LOT \ I� I - 77781 REED � I �� CENTER OF GEODETIC COORDINATES / LAT = 39° 13'07.28" NORTH I I 7 .4 TREE LON.-106° 51' 35.45" WEST / JJJIII ELEV. tQ GROUND = 7777 7776 '1. (E) OVERHANG OH J/ v YTJ 7]76a EP 7787.90H � � I 7776.6 EP 7818.5 7772 SW ly, a I a ° (E) SIDEWALK a � 80738T EE 11I 7797.8 PRPP NATURAL GROUND 77 /wj E 7777.0 NG 1T�Sj iR RW.8 PRPT 719'!.7 PRPP Q 7797.9 PRT 7197.8 RT O 7197.2 FS ]]97.3 PRT ' I 1808.7 TREE 7178.1 EP NATURAL ]778. 7798.7 F5 1 3W (E) ROOFTOP � 1]96.8 FS / / GROUND / 7199.1 BLDGV Y/ JC D xxxx 760BA N O 0 � 3 (E) ROOFTOP 7808 7 TREE II p ® 7198.] FS e 7197.4 PRPT " 7804.8 T ® DO 7197.9 PRT 7]97.] PRT O ]191.0 FS MT PRT , - 7 8IT EE e 0 O 7/92.0 BLDG 7006.8 ANT 5 O 7808.9 ANT 7799.2 BLDG ]797.2 OH 7187.5 OH ( )°P (E)BUILDING 7804.5 ANT 7791A BLD 77'T9EP V N 7]98.7 FS / 7808.4ANT (E)OVERHANG (E) WIRE FENCE 7796.9 FS 77971 PRT I / W 7799.1 BLDG O 7791.5 BLDG z I� (E) ROOFTOP I I 77996 BLDG (E) ROOFTOP J7798.2 Fs 7191.2 PRT 7/912 PRPT I (E) EDGE OF PAV[� I WI G (E)GATE 7783.8 BLDG 7791.2 PRT N Gam° (E) ROOFTOP L18 6 779 83 GPRT 1.3 PRT 91.5 GPS L9 L23 v 7785A OH /NATURAL r ) / GROUND 7182.8 BLDG ]776.8 EP7 .6 BLDG NATURAL o 77]6.9 EP U L11 (m8.8 PV I 4/ I m I GROUND u (E) EDGE OF PAVEMENT i L add O/ IX G 7778.7 EP 1� L7 RRX EP _777. 8 EP G_ G G 10 G G 0 4 r 7778.7NG (E) BUILDING I 'D ASPHALT 77 G- 0 n m / PARKING I 7 .0MEE /o (P)VERIZON WIRELESS I UTILITY EASEMENT .2 TRE r I (P) VERIZON WIRELESS m / ACCESS EASEMENT -7778 'o /ko v o Oo / PO. .C. (P) VERIZON WIRELESS / jCCESS EASEMENT P.O.C. (P) VERIZON WILES UTILITY ENi 25' 33W y�10'2-rw 3e.ea' _ oRS "_ 1 L2 61.aa - - u I ( / c L28� l � P.06 -; VCRIZO\' VJ112(P) VERIZON WIRE S ACCESS EASEMENT LL_SS - UTILITY EASEMENT VERIZON WIRELESS ACCESS EASEMENT LEGAL DESCRIPTION A PORTION OF LOT 3, BLOCK 5, AMENDED AND RESTATED PLAT OF ASPEN AIRPORT BUSINESS CENTER FILING NO. 1, ACCORDING TO THE PLAT THEREOF FILED APRIL 16, 1979, IN PLAT BOOK 7 AT PAGE 7, PITKIN, COUNTY COLORADO, DESCRIBED AS FOLLOWS: COMMENCING AT THE SOUTHEAST CORNER OF SAID LOT 3; THENCE NORTH 89'10'27" WEST ALONG THE SOUTH LINE OF SAID LOT 3, 40.81 FEET TO THE POINT OF BEGINNING. THENCE CONTINUING ALONG SAID SOUTH LINE NORTH 89°10'27" WEST, 12.41 FEET; THENCE DEPARTING SAID SOUTH LINE NORTH 37°08'40" EAST, 18.81 FEET; THENCE NORTH 49"58'23" EAST, 32.38 FEET; THENCE NORTH 19°07'54" EAST, 20.89 FEET; THENCE NORTH 01°51'40" EAST, 2.96 FEET; THENCE NORTH 90°00'00" WEST, 52.47 FEET; THENCE NORTH 00°00'00" EAST, 17.49 FEET, THENCE SOUTH 89°15'56" EAST, 12.49 FEET;THENCE SOUTH 00°00'00" EAST, 7.33 FEET; THENCE NORTH 90°00'00" EAST, 50.32 FEET; THENCE SOUTH 01°5140' WEST, 14.81 FEET; THENCE SOUTH 19°07'54" WEST, 2516 FEET; THENCE SOUTH 49°5823" WEST, 34.02 FEET; THENCE SOUTH 37°08'40" WEST, 10.34 FEET TO THE SOUTH LINE OF SAID LOT 3 ALSO BEING THE POINT OF BEGINNING. VERIZON WIRELESS UTILITY EASEMENT LEGAL DESCRIPTION A PORTION OF LOT 3, BLOCK 5, AMENDED AND RESTATED PLAT OF ASPEN AIRPORT BUSINESS CENTER FILING NO. 1, ACCORDING TO THE PLAT THEREOF FILED APRIL 16, 1979, IN PLAT BOOK 7 AT PAGE 7, PITKIN, COUNTY COLORADO, DESCRIBED AS FOLLOWS: COMMENCING AT THE SOUTHWEST CORNER OF SAID LOT 3; THENCE NORTH 85°25'33" EAST ALONG THE SOUTH LINE OF SAID LOT 3, 10.92 FEET TO THE POINT OF BEGINNING. THENCE DEPARTING SAID SOUTH LINE NORTH 01°45'25" WEST, 81.88 FEET; THENCE SOUTH 89°08'13" EAST, 5.01 FEET; THENCE SOUTH 01°45'25" EAST, 65.09 FEET; THENCE NORTH 26°59'14" EAST, 34.35 FEET; THENCE NORTH 17°38'24" EAST, 16.12 FEET; THENCE NORTH 39°2455" EAST, 19.80 FEET; THENCE SOUTH 89°1656" EAST, 6.41 FEET; THENCE SOUTH 39°24'55" WEST, 22.84 FEET; THENCE SOUTH 17°38'24" WEST, 15.56 FEET; THENCE SOUTH 26°59'14" WEST, 43.87 FEET; THENCE SOUTH 01 °45'25" EAST, 5.91 FEET TO THE SOUTH LINE OF SAID LOT 3; THENCE SOUTH 85°25'33" WEST ALONG SAID SOUTH LINE, 5.01 FEET TO THE POINT OF BEGINNING. LINE TABLE LINE LENGTH BEARING L1 40.81 N89° 10'27W L2 12.41 N89° 10' 27"W L3 18.81 N37° OB' 40"E L4 32.38 N49° 58' 23"E L5 20.89 N19° 07' WE L6 2.96 N7°5V40"E L7 52.47 N90° 00'00"W L8 17.49 NO* 00' 00"E L9 12.49 S89° 15' 56"E L10 7.33 SO' 00' OWE L71 50.32 N90° 00' 00"E L12 14.81 S1°51'40"W L13 25.16 S19° 07' 54"W L14 34.02 34V 58'23W LINE TABLE LINE LENGTH BEARING LIS 10.34 S37° OB' 40"W L16 10.92 N85° 25' 33"E L17 81.88 N1°4625"W L18 5.01 389° OV 13"E 1-19 65.09 $1 ° 45'25"E L20 34.35 N26° 59' 14"E L21 16.12 N17° 38' 24"E L22 19.80 N39° 24' 55"E L23 6.41 S89° 15' 56"E L24 22.84 S39" 2455"W L25 15.56 S17° 38' 24W L26 43.87 S26° 59114W L27 5.91 81 ° 45' 25"E L28 5.01 SW 25' 33"W LEGEND r / go 5, MAGNETIC NORTH DECLINATION GRAPHIC SCALE 10 0 5 10 20 40 ( IN FEET ) 1 inch = 10 ft verizon%l 3131 S. VAUGHN WAY, SUITE 550 AURORA, CO 80014 FIELD BY: JWS DRAWN BY; CRS CHECKED BY: ABM REVISIONS 1 2 12/13/17 TITLE REVIEW AND FINAL 1 11/20/17 PRELIMINARY NO. DATE DESCRIPTION !�TF==�) L CONSULTING �W k STAL1eN1 de hn. TErr1rE A2u 9�J29i www.rxxws��rirv�.carn �aa��aiao REUSE OF DOCUMENT THE IDEAS& DESIGN INCORPORATED HEREON, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF RLF CONSULTING, LLC & IS NOT TO BE USED FOR ANY OTHER PROJECT WITHOUT WRITTEN AUTHORIZATION OF RLF CONSULTING, LLC. PROJECT No. 15010134 SITE NAME: ASPEN AIRPORT SITE ADDRESS: 301 ASPEN AIRPORT BUSINESS CENTER ASPEN, CO 81611 SHEET TITLE: TOPOGRAPHIC SURVEY SHEET NO. REVISION: LS -2 OO FOUND AS NOTED ® AIR CONDITIONING UNIT N ELECTRIC METER N ELECTRIC SWITCH © ELECTRICAL TRANSFORMER D FIBER VAULT o TELEPHONE PULL BOX POWER POLE F DOWN GUY Q VENT RISER o VENT PIPE ® ROOF DRAIN ANTENNA O GAS METER $ FIRE HYDRANT pQ WATER VALVE 0 WATER METER ® BACKFLOW PREVENTER IRRIGATION CONTROL VALVE ® STORM DRAIN GRATE • DECIDUOUS TREE BREAKLINE X szeo.00 Nc SPOT ELEVATION POSITION OF GEODETIC COORDINATES - - PROPERTY LINE - - PROPERTY LINE (OTHER) - CENTERLINE O O CHAIN LINK FENCE OHE OHE OVERHEAD ELECTRIC LINE uGE UGE U/G ELECTRIC LINE T T T U/G TELECOMMUNICATION LINE -FO-FO-FO-U/G FIBER OPTIC LINE c c c U/G GAS LINE SD SD SD STORM SEWER LINE APN ASSESSORS PARCEL NUMBER ANT ANTENNA BLDG BUILDING CS CONCRETE SURFACE DAV DRIVEWAY FS FINISH SURFACE NG NATURAL GRADE OVH OVERHANG TOP PV ASPHALT SW SIDEWALK RA/ RIGHT OF WAY r / go 5, MAGNETIC NORTH DECLINATION GRAPHIC SCALE 10 0 5 10 20 40 ( IN FEET ) 1 inch = 10 ft verizon%l 3131 S. VAUGHN WAY, SUITE 550 AURORA, CO 80014 FIELD BY: JWS DRAWN BY; CRS CHECKED BY: ABM REVISIONS 1 2 12/13/17 TITLE REVIEW AND FINAL 1 11/20/17 PRELIMINARY NO. DATE DESCRIPTION !�TF==�) L CONSULTING �W k STAL1eN1 de hn. TErr1rE A2u 9�J29i www.rxxws��rirv�.carn �aa��aiao REUSE OF DOCUMENT THE IDEAS& DESIGN INCORPORATED HEREON, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF RLF CONSULTING, LLC & IS NOT TO BE USED FOR ANY OTHER PROJECT WITHOUT WRITTEN AUTHORIZATION OF RLF CONSULTING, LLC. PROJECT No. 15010134 SITE NAME: ASPEN AIRPORT SITE ADDRESS: 301 ASPEN AIRPORT BUSINESS CENTER ASPEN, CO 81611 SHEET TITLE: TOPOGRAPHIC SURVEY SHEET NO. REVISION: LS -2 (0 Z_ 0 Z w 0 w W W O 0_ O w w m L �m LL w W m m U 0 U ces m r m= RACK OVP VAPPROX. K OVP @ EQ. EQ. ROOM OOM PAIR DC W IRE PAIR DC W IRE APPROX. 6 L.F. 6 L.F. 1 PDU 1 °O W Q M o W z W d 13- m m m a m W w 2 - HYBRID CABLE DIAGRAM —iIL_ (E) MECHANICP EQUIPMENT ROUTE (2) NEW CABLES IN (E) Al COVERED CABLI -NEW COVEREF RE: 4/A4.00 J■ (E) COVERED C ■ d— (E) EXHAUST PI e (6) (E) VERIZON ® ANTENNAS OMI REMOVE (4) RE ■ (E) HIGH ROI ■ (E) LOW ROOF (2) NEW 6X12 HYBRID CABLES, ROUTE IN (E) VACANT U.G. 6"0 CONDUITS TO VERTICAL CABLE CHASE RE: 2/A1.00 FOR LENGTH I WI I I co —�W I I. II / cm II / L. Lu W 1 Ti W1 ui 1 / co co I W I Lj / (E) U.G. FIBER f v 1 -SITE PLAN veria®nv' VERIZON WIRELESS SERVICES 3131 S. VAUGHN WAY, SUITE 550 AURORA, CO 80014 PROJECT INFORMATION SITE NAME CO3 ASPEN AIRPORT SITE I.D. 264 301 ASPEN AIRPORT BUSINESS CENTER ASPEN, CO 81611 CONSULTANT A 10/30/17 CONCEPT RSS B 11/06/17 RF COMMENTS RSS C 01/05/18 CLIENT COMMENTS RSS D 02/05/18 L.L. COMMENTS RSS E 03/01/18 CLIENT COMMENTS RSS 1st REVIEW SSB 2nd REVIEW KMS 1/16" = 5935 SOUTH ZANG STREET, SUITE 280 LITTLETON, COLORADO 80127 OFFICE: 303.932.9974 NOT FOR CONSTRUCTION SITE PLAN AND HYBRID CABLE DIAGRAM A1.00 RACK OVP @ EQ. ROOM TO MAIN OVP ANTENNAS RACK OVP @ EQ. ROOM 6X12 HYBRID CABLE MAIN OVP @ ANTENNAS QTY. LENGTH QTY. WEIGHT QTY. U ZU g (2) 220 L.F. EACH (2) 633.6 LBS (1.44 LBS/L.F.) (1) llY w 0 MAIN OVP TO RRH CONNECTION LL 1X1 HYBRID CABLE 700 RRH PCS AWS RRH RRH 850 RRH LENGTH QTY. QTY. QTY. QTY. QTY. X 10'-01. 4 1 1 1 1 Y 10'-01. (4) (1) (1) (1) (1) Z 10'-0"(4) 1 1 1 1 NOTE: 1. RE: 1/A2.30 FOR ANTENNA CONFIGURATION AND RRH AND MAIN OVP LOCATIONS. O RACK OVP VAPPROX. K OVP @ EQ. EQ. ROOM OOM PAIR DC W IRE PAIR DC W IRE APPROX. 6 L.F. 6 L.F. 1 PDU 1 °O W Q M o W z W d 13- m m m a m W w 2 - HYBRID CABLE DIAGRAM —iIL_ (E) MECHANICP EQUIPMENT ROUTE (2) NEW CABLES IN (E) Al COVERED CABLI -NEW COVEREF RE: 4/A4.00 J■ (E) COVERED C ■ d— (E) EXHAUST PI e (6) (E) VERIZON ® ANTENNAS OMI REMOVE (4) RE ■ (E) HIGH ROI ■ (E) LOW ROOF (2) NEW 6X12 HYBRID CABLES, ROUTE IN (E) VACANT U.G. 6"0 CONDUITS TO VERTICAL CABLE CHASE RE: 2/A1.00 FOR LENGTH I WI I I co —�W I I. II / cm II / L. Lu W 1 Ti W1 ui 1 / co co I W I Lj / (E) U.G. FIBER f v 1 -SITE PLAN veria®nv' VERIZON WIRELESS SERVICES 3131 S. VAUGHN WAY, SUITE 550 AURORA, CO 80014 PROJECT INFORMATION SITE NAME CO3 ASPEN AIRPORT SITE I.D. 264 301 ASPEN AIRPORT BUSINESS CENTER ASPEN, CO 81611 CONSULTANT A 10/30/17 CONCEPT RSS B 11/06/17 RF COMMENTS RSS C 01/05/18 CLIENT COMMENTS RSS D 02/05/18 L.L. COMMENTS RSS E 03/01/18 CLIENT COMMENTS RSS 1st REVIEW SSB 2nd REVIEW KMS 1/16" = 5935 SOUTH ZANG STREET, SUITE 280 LITTLETON, COLORADO 80127 OFFICE: 303.932.9974 NOT FOR CONSTRUCTION SITE PLAN AND HYBRID CABLE DIAGRAM A1.00 00 ¢orb 0o aLr?c U ZU g Z wg 0 w 0 LL LL LL LL LL LL xx xx (V cV (V IV (V (V O O 7 N N N N 7 W W Of rn o^ a o O U �W MW _ MW _ mW W (n J J J J Q 2 Q U 2 Q 2 Q2 U Q U U X x X X F �} U Lu F -> z Q RACK OVP VAPPROX. K OVP @ EQ. EQ. ROOM OOM PAIR DC W IRE PAIR DC W IRE APPROX. 6 L.F. 6 L.F. 1 PDU 1 °O W Q M o W z W d 13- m m m a m W w 2 - HYBRID CABLE DIAGRAM —iIL_ (E) MECHANICP EQUIPMENT ROUTE (2) NEW CABLES IN (E) Al COVERED CABLI -NEW COVEREF RE: 4/A4.00 J■ (E) COVERED C ■ d— (E) EXHAUST PI e (6) (E) VERIZON ® ANTENNAS OMI REMOVE (4) RE ■ (E) HIGH ROI ■ (E) LOW ROOF (2) NEW 6X12 HYBRID CABLES, ROUTE IN (E) VACANT U.G. 6"0 CONDUITS TO VERTICAL CABLE CHASE RE: 2/A1.00 FOR LENGTH I WI I I co —�W I I. II / cm II / L. Lu W 1 Ti W1 ui 1 / co co I W I Lj / (E) U.G. FIBER f v 1 -SITE PLAN veria®nv' VERIZON WIRELESS SERVICES 3131 S. VAUGHN WAY, SUITE 550 AURORA, CO 80014 PROJECT INFORMATION SITE NAME CO3 ASPEN AIRPORT SITE I.D. 264 301 ASPEN AIRPORT BUSINESS CENTER ASPEN, CO 81611 CONSULTANT A 10/30/17 CONCEPT RSS B 11/06/17 RF COMMENTS RSS C 01/05/18 CLIENT COMMENTS RSS D 02/05/18 L.L. COMMENTS RSS E 03/01/18 CLIENT COMMENTS RSS 1st REVIEW SSB 2nd REVIEW KMS 1/16" = 5935 SOUTH ZANG STREET, SUITE 280 LITTLETON, COLORADO 80127 OFFICE: 303.932.9974 NOT FOR CONSTRUCTION SITE PLAN AND HYBRID CABLE DIAGRAM A1.00 z Z Lu w Q QU)Q W W Q C7 Lu Z ~ W xtxn J W F Z Lu Z LU Z w Lu U) ug S J F Z i5 O U U W U Z Q (w_7 1 - EQUIPMENT ROOM FLOOR PLAN 1/2" = T-0" veria®n,wl VERIZON WIRELESS SERVICES 3131 S. VAUGHN WAY, SUITE 550 AURORA, CO 80014 PROJECT INFORMATION SITE NAME CO3 ASPEN AIRPORT SITE I.D. 264 301 ASPEN AIRPORT BUSINESS CENTER ASPEN, CO 81611 CONSULTANT A 10/30/17 CONCEPTRSS B 1 1/06/1 7 RF COMMENTS RSS C 01/05/18 CLIENT COMMENTS RSS D 02/05/18 L.L. COMMENTS RSS E 03/01/18 CLIENT COMMENTS RSS 1st REVIEW SSB 2nd REVIEW KMS 5935 SOUTH ZANG STREET, SUITE 280 LITTLETON, COLORADO 80127 OFFICE: 303.932.9974 NOT FOR CONSTRUCTION EQUIPMENT ROOM FLOOR PLAN A2.00 z Z Lu w Q QU)Q W W Q C7 Lu Z ~ W xtxn J W F Z Lu Z LU Z w Lu U) ug S J F U) i5 O U U W (.5 Z Q (w_7 O W !Y W m LL X �m LL 11 J m Q U 0 0 U 2 °d �0 7 m mr m= 1 - EQUIPMENT ROOM REFLECTED CEILING PLAN "GROUND BAR J -BOX IS SPLITTER ) ADD NEW GPS TER AND 4 -WAY 'FLITTER ;HAUST FAN AND HOOD 1/2" = T-0" veria®nv' VERIZON WIRELESS SERVICES 3131 S. VAUGHN WAY, SUITE 550 AURORA, CO 80014 PROJECT INFORMATION SITE NAME CO3 ASPEN AIRPORT SITE I.D. 264 301 ASPEN AIRPORT BUSINESS CENTER ASPEN, CO 81611 CONSULTANT A 10/30/17 CONCEPTRSS B 1 1/06/1 7 RF COMMENTS RSS C 01/05/18 CLIENT COMMENTS RSS D 02/05/18 L.L. COMMENTS RSS E 03/01/18 CLIENT COMMENTS RSS 1st REVIEW SSB 2nd REVIEW KMS 5935 SOUTH ZANG STREET, SUITE 280 LITTLETON, COLORADO 80127 OFFICE: 303.932.9974 NOT FOR CONSTRUCTION EQUIPMENT ROOM RCP A2.1 0 z z w Z W z w W U) ug S J F 7 Z i5 O U) U (w7 veria®nv' VERIZON WIRELESS SERVICES 3131 S. VAUGHN WAY, SUITE 550 AURORA, CO 80014 PROJECT INFORMATION SITE NAME CO3 ASPEN AIRPORT SITE I.D. 264 301 ASPEN AIRPORT BUSINESS CENTER ASPEN, CO 81611 CONSULTANT A 10/30/17 CONCEPTRSS B 1 1/06/1 7 RF COMMENTS RSS C 01/05/18 CLIENTCOMMENTS RSS D 02/05/18 L.L. COMMENTS RSS E 03/01/18 CLIENT COMMENTS RSS 1st REVIEW SSB 2nd REVIEW KMS 5935 SOUTH ZANG STREET, SUITE 280 LITTLETON, COLORADO 80127 OFFICE: 303.932.9974 NOT FOR CONSTRUCTION OMNI ANTENNA PLANS A2.20 (E) LOW ROOF NEW COVERED CABLE TRAY (NON PENETRATING) (E) CDMA OMNI RE: 5/A4.00 CDMA OMNI (E) (TO REMAIN) (E) 700 OMNI (REMOVE) O (E) EXHAUST PIPE (E) EXHAUST PIPE (E) AWS OMNI (REMOVE) O — (E) AWS OMNI (REMOVE) (E) PARAPET (TYP.) (E) PARAPET (TYP.) (E) EMPTY PIPE MOUNT (TYP. OF 4) (E) 700 OMNI (REMOVE) (E) COVERED CABLE TRAY (E) COVERED CABLE TRAY O (E) HIGH ROOF (E) VERTICAL COAX CHASE (E) VERTICAL COAX CHASE AND COVER AND COVER (E) CDMA OMNI yt (E) CDMA OMNI (TO REMAIN) t t 2 -OMNI ANTENNA DEMO PLAN 1/4" = 11-01, 1 - NEW OMNI ANTENNA PLAN 1/4" = V-0" veria®nv' VERIZON WIRELESS SERVICES 3131 S. VAUGHN WAY, SUITE 550 AURORA, CO 80014 PROJECT INFORMATION SITE NAME CO3 ASPEN AIRPORT SITE I.D. 264 301 ASPEN AIRPORT BUSINESS CENTER ASPEN, CO 81611 CONSULTANT A 10/30/17 CONCEPTRSS B 1 1/06/1 7 RF COMMENTS RSS C 01/05/18 CLIENTCOMMENTS RSS D 02/05/18 L.L. COMMENTS RSS E 03/01/18 CLIENT COMMENTS RSS 1st REVIEW SSB 2nd REVIEW KMS 5935 SOUTH ZANG STREET, SUITE 280 LITTLETON, COLORADO 80127 OFFICE: 303.932.9974 NOT FOR CONSTRUCTION OMNI ANTENNA PLANS A2.20 ug Q Lu ug J z z Lu w ug F U) U) Lu U d Lu d Lu J Lu d O d w w m LL 1. REMOVE EXISTING ROOFING MATERIALS DOWN TO (E) DECKING OR AS REQUIRED FOR t PENETRATIONS. Y 1 2. RE -ROOF TO MATCH EXISTING ROOFING. INSTALL FLASHING & LAPPED JOINT TO Li EXISTING ROOFING AS REQ. AND PER SPECIFIC ROOFING SYSTEM SPECIFICATIONS. L 3. INSTALL FLASHING AND ROOFING SYSTEM PER THE MANUFACTURER'S CURRENTLY PUBLISHED DETAILS AND NRCA DETAILS. 4. SUBMIT ROOFING DETAILS AND SPECS TO PROJECT MANAGER FOR REVIEW PRIOR TO INSTALLATION. t 5. RE -ROOF, FLASH AND SEAL ALL OPENINGS PRIOR TO LEAVING THE JOB SITE. DO NOT Li LEAVE ROOFING PENETRATIONS OPEN OVERNIGHT OR UNATTENDED. t 6. SCHEDULE ROOFING OPERATIONS TO AVOID INCLEMENT WEATHER. 7. PROVIDE PROTECTION AS REQUIRED TO AVOID LEAKAGE AND DAMAGE TO INTERIOR. 8. MAINTAIN EXISTING ROOFING DRAINAGE PATTERNS. 9. MAINTAIN EXISTING ROOFING WARRANTY. CALL FOR REQUIRED INSPECTION. USE u ROOFING COMPANY RESPONSIBLE FOR WARRANTY. CONTACT OWNER. Li 10. ALL METAL FLASHING SHALL BE PRIMED AND PAINTED OR GALVANIZED PER PLANS & DETAILS. 7 11. PROTECT EXISTING ROOF SYSTEM DURING NEW CONSTRUCTION AND DEMOLITION WITH SURFACE SHEATHING CONTINUOUS THROUGHOUT WORK AREAS. Li 12. IDENTIFY ALL LEAK LOCATIONS AND REMOVE AND REPLACE ALL WET MATERIALS TO MATCH EXISTING CONDITIONS. II 3 - ROOFING NOTES ATTACH PL 1/2"X36"X36" WITH 1/4"X1" LAG SCREWS TO (E) JOISTS AND PLYWOOD RE: PLAN 11/2." 3" STYE .) WELD ON POST D -RING GUARDIAN MODEL #: CB -18 WELD ON POST (OR EQ.) PIPE BOOT FLASHING RE: 6/A4.00 5/16" V (E) SPM ROOFING OVER RIGID INSULATION (E) 3/4" T&G PLYWOOD (E) 14" BCI/6000 JOISTS @ 16" O.C. SECTION LATTACH PL 1/2"X36"X36" WITH 1/4"X1" LAG 1/2" SCREWS TO (E) JOISTS elK_ AND PLYWOOD —= 0 0 0 0 0 0 0 0 0 0 Y Li n L 1 1/2" 3" - r 0---a y --- 5/16" C 0 0 0 0 0 0 0 0 0 0 0 PLAN 2 - D -RING ATTACHMENT DETAIL WELD ON POST D -RING GUARDIAN MODEL #: CB -18 WELD ON POST (OR EQ.) 1/2" (E) 14" BCI/6000 JOISTS @ 16" O.C. - (E) PARAPET (TYP.) --\6' 4" l 10'-11" (E) MECHANICAL EQUIPMENT NEW STANDOFF MOUNT SITE PRO PART #: MM02 (OR EQ.) - -N - - - - - - - \ Gm Z O�NEW PCS/700/850 MODEL #: JAHH-6513- 0 — .R3B (TYP. OF 3) RE: 2/A4.00- — NEW AWS/700/850 MODEL #: JAHH-65B-R3B (TYP. OF 3) RE: 2/A4.00 NEW CROSSOVER KIT SITE PRO PART #: SCX6- (TYP. OF 2 PER SECTOR) U (OR EQ.) (TYP. OF 2 — — — — — — — — — —PER ANTENNAr NEW 2-3/8" O X T-0" SCHED. 40 GALV. i ANTENNA PIPE (TYP. OF 6) — — NEW TRIPOD BALLAST F FRAME SITE PRO PART #: TRPD-HD (OR EQ.) WITH NO2 — — — — — — — — — / ON ISOLATION PADSPLACE V �AT \M CORNER TO ALLOW WROOF -- — -- — TODRAN- NEW / E ! �MSTRE: STRUCTURAL �Oo40 GALVHORIZONTAL PPE 1iL Oo (TYP. OF 2 PER SECTOR) — — — — — — — — — — — — — — - --- -- ~-------- LL NEW COVERED CABLE— — — — — — — — — — — — — (E) ROOF DRAIN TRAY (NON PENETRATING) RE: 4/A4.00 MIN. 10'_ 0" — — — — — — — — — — — — — - — - - (E) ROOF OVERHANGI I - — — — — — — — (E) WALL BELOW ROOF OVERHANG(TYP.) — NEW D -RING, ATTACH TO (E) o — — — — ROOF JOISTS RE: 2/A2.30 (3) ALU RRH 4X45 -AWS (3) ALU RRH 4X30 -PCS 50 —--------- ()-- --- E 14" BCI/6000 JOISTS (3) ALU RRH 4X30-700 AT (3) NOKIA RRH 4X40-850 ------------------------ (1) OVP MODEL #: RCMDC-6627-PF-48 ON — — NEW BALLASTED H -FRAME — — — — — — — — — — — — — — RE: 2/A4.00 0 3/4" = 13/a" _ -011 - NEW ANTENNA PLAN- NEW ANTENNA PLAN (E) ROOF SYSTEM: SPM ON RIGID INSULATION 3/4" T&G PLYWOOD 14" BCI/6000 JOISTS AT 16" O.C. NOTES: 1. RE: STRUCTURAL BY: OTEGUI STRUCTURAL DATED: 01/05/17. 2. MAINTAIN (E) ROOF DRAINAGE PATTERN. 3. RE: 4/G1.00 FOR ANTENNA NOTES. 4. CONTRACTOR TO UTILIZE (E) BUILDING ROOFER. 1/4" = V-0" veria®nv' VERIZON WIRELESS SERVICES 3131 S. VAUGHN WAY, SUITE 550 AURORA, CO 80014 PROJECT INFORMATION SITE NAME CO3 ASPEN AIRPORT SITE I.D. 264 301 ASPEN AIRPORT BUSINESS CENTER ASPEN, CO 81611 CONSULTANT A 10/30/17 CONCEPT RSS B 11/06/17 RF COMMENTS RSS C 01/05/18 CLIENT COMMENTS RSS D 02/05/18 L.L. COMMENTS RSS E 03/01/18 CLIENT COMMENTS RSS 1st REVIEW SSB 2nd REVIEW KMS 5935 SOUTH ZANG STREET, SUITE 280 LITTLETON, COLORADO 80127 OFFICE: 303.932.9974 NOT FOR CONSTRUCTION NEW ANTENNA PLAN AND DETAILS A2.30 U) z O Q w z w o_ z z Lu z I z z w w Q QmQ W W Q C7 Lu Z ~ W xtxn J W z z w Z W Z w W U) ug S J F Z i5 O W U U Z Q (w_D (D z 0 z Lu. w cD w w d � O d O Lu Ir Lu m LL �m LL V) Lu J m U 0 O U x °d �0 � m m Y m x NEW RF EQUIPMENT (6) (E) VERIZON WIRELESS ON BALLASTED FRAME ANTENNAS OMNI ANTENNAS, RE: A2.30, NOTE 2 T.O. E OMNI ANTENNAS REMOVE (4) RE: A2.20 (E) EXHAUST PIPE 30' - 0" n n II II II II 1 II II � II II i u u i u u (E) VERIZON WIRELES EQUIPMENT ROOM RE: A2.00, A2.10 2 - EAST ELEVATION T.O. NEW ANTENNAS 29' - 6" NEW VERIZON WIRELESS RAD CENTER- 2 ENTER 26' - 1. 1 -NORTH ELEVATION (6) NEW 6'H VERIZON WIRELESS ANTENNAS ON BALLASTED NEW COVERED CABLE ANTENNA FRAME RE: A2.30, NOTE 2 TRAY W ITH (2) 6X12 HYBRID CABLES RE: A1.00 T.O. NEW ANTENNAS 29'- 6" 1 NEW VERIZON WIRELESS RAD CENTER i 26'-6° (E) MECHANICAL In EQUIPMENT T.O. HIGH PARAPET 22'- 6" T.O. MID PARAPET 20'- 6" (6) NEW 6'H VERIZON WIRELESS ANTENNAS ON BALLASTED ANTENNA FRAME RE: A2.30, NOTE 2 NEW RF EQUIPMENT ON BALLASTED FRAME RE: A2.30, NOTE 2 (E) EXHAUST PIPE (E) MECHANICAL EQUIPMENT NEW COVERED CABLE TRAY WITH (2) 6X12 HYBRID CABLES RE: A1.00, 4/A4.00 (E) BUILDING GRADE 0' - 0" 1/8" = 1'-0" T.O. (EOMNI ANTENNAS I1 (6) (E) VERIZON WIRELESS ANTENNAS OMNI ANTENNAS, REMOVE (4) RE: A2.20 (E) COVERED CABLE TRAY T.O. HIGH PARAPET 2�6" T.O. MID PARAPET L 2 (E) VERTICAL COVERED COAX CHASE (E) BUILDING NOTES: 1. RE: STRUCTURAL BY: OTEGUI STRUCTURAL SERVICES DATED: 01/05/18 2. NEW ANTENNAS AND EQUIPMENT PAINTED TO MATCH (E) BUILDING BROWN. GRADE III� 1/8" = 1'-0" veria®nv' VERIZON WIRELESS SERVICES 3131 S. VAUGHN WAY, SUITE 550 AURORA, CO 80014 PROJECT INFORMATION SITE NAME CO3 ASPEN AIRPORT SITE I.D. 264 301 ASPEN AIRPORT BUSINESS CENTER ASPEN, CO 81611 CONSULTANT A 10/30/17 CONCEPTRSS B 1 1/06/1 7 RF COMMENTS RSS C 01/05/18 CLIENT COMMENTS RSS D 02/05/18 L.L. COMMENTS RSS E 03/01/18 CLIENT COMMENTS RSS 1st REVIEW SSB 2nd REVIEW KMS 5935 SOUTH ZANG STREET, SUITE 280 LITTLETON, COLORADO 80127 OFFICE: 303.932.9974 NOT FOR CONSTRUCTION ELEVATIONS A3.00 z z Lu w Q QmQ W W Q C7 Lu Z ~ W xtxn J W z z Lu Z LU z w Lu U) ug S J F Z i5 O U U W U Z Q (w_7 O w !r w m LL W �m LL 11 m U O U od �0 �m mr m x COLUMN / CONDUIT RE: PLAN CONT. SEALANT (TYP) DRAWBAND 2-3/8"0 SCHEDULE 40 GALVANIZED PIPE MOUNT FULLY ADHERED MEMBRANE RRH ATTACHED PER COUNTER MARCHING MFR. SPECS. REMOVE (E) SPM & (BEYOND) 2 INSULATIONAT BASEPLATE Z) FULLY ADHERED MEMBRANE 2 LOCATIONS, REPLACE W/ FLASHING z FOAM INSULATION i g MOUNTING BRACKE BY MANUFACTURE 3"0X3'-0" SCHED. 40 (TYP) SUPPORTS EA. SIDE OF ROOF 5 - PIPE BOOT FLASHING DETAIL SECTION B -B 4 - ROOFTOP CABLE TRAY DETAIL N.T.S. CONDUIT SIZE & COUNT PER PLAN (ATTACH TO CABLE TRAY RUNGS @ 4'-0" W/ STAINLESS STEEL CLIPS) SHT. METAL COVER ATTACHED TO RAILS WITH TEK SCREWS AT 12" O.C. 12"W X 4"D CABLE TRAY ATTACH CABLE TRAY TO EACH W.F. W/ 3/8"0 THRU BOLT EA. SIDE W8x10 CABLE TRAY SUPPORT @ 48" O.C. 1/2" WALK -PAD BELOW NEOPRENE PAD ON ROOF (DO NOT ADHERE TO ROOF) NEOPRENE PAD, ADHERE TO W.F. SUPPORT WITH APPROVED ADHESIVE :S: MENSIONS ARE FOR 12"W TRAY EOPRENE PAD MUST BE 2" LARGER THAN I -BEAM FOOTPRINT (CENTER AND ADHERE TO BOTTOM OF W.F. 3. PRIME AND PAINT OR HOT DIP GALV. W.F. 4. DO NOT ADHERE PAD TO ROOF. 4 _u 5'-0" PLAN OVP ATTACHED PER MFR. SPECS. P1000 UNISTRUT T&B (4) SIDES, ATTACH TO EA. POST W/ 1/2"0 U- BOLTS(SET LEVEL) RRH ATTACHED PER MFR. SPECS. 3"0X3'-0" SCHED. 40 GALV. PIPE (TYP.) 1/2"0 U -BOLT (TYP.) W10X12X4'-0" (TYP.) 1/2" NEOPRENE ROOFING PAD (DO NOT BOND TO ROOF) (E) ROOF SYSTEM ELEVATION 3/4"=V-0" I 3 - H -FRAME DETAIL BALLAST FRAME L2X2X3/16 X 0-10" THRU-BOLTED TO W.F. W/ (2) 1/2"0 THRU BOLTS (TYP. OF 4) TRIM TO FIT ANTEN (TYP.) PANEL ANTENNA 1/2"0 COAX TO RRH RE: PLAN NOTES: 1 REFER TO ANTENNA MANUFACTURER SPEC FOR QUANTITY OF MOUNTING BRACKETS REQUIRED. 2. GROUND RRH PER VERIZON WIRELESS SPECIFICATIONS RE: A6.00 2 -ANTENNA MOUNTING DETAIL 1/2" = V-0" INTERIOR VIEW XO X1 (6) (E) 7/8" COAX, ® O O O REMOVE (4) O LXOLX1 AXO AX1 (2) NEW 6x12 HYBRID CABLES Q (4) (E) 6"0 FLOOR 0( PORTS NEW7EXISTINGI DEMO/[--] EXISTING ACTIVE REMOVED INACTIVE 1/2" = 1'-0° I 1 - COAX ENTRY PORT DETAIL 1 1/2" = 1'-0" veria®nv' VERIZON WIRELESS SERVICES 3131 S. VAUGHN WAY, SUITE 550 AURORA, CO 80014 PROJECT INFORMATION SITE NAME CO3 ASPEN AIRPORT SITE I.D. 264 301 ASPEN AIRPORT BUSINESS CENTER ASPEN, CO 81611 CONSULTANT A 10/30/17 CONCEPTRSS B 1 1/06/1 7 RF COMMENTS RSS C 01/05/18 CLIENT COMMENTS RSS D 02/05/18 L.L. COMMENTS RSS E 03/01/18 CLIENT COMMENTS RSS 1st REVIEW SSB 2nd REVIEW KMS 5935 SOUTH ZANG STREET, SUITE 280 LITTLETON, COLORADO 80127 OFFICE: 303.932.9974 NOT FOR CONSTRUCTION DETAILS A4.00 U) z O a w z w 0_ U) Q Z Z W z Q z z w w Q Q w Q z Z W F V) V) J W R F - z w Z W z w W U) J F Z i5 O U) V U Z C7 z zz Lu. U C7 Lu a J LU w d � O d O Lu Df Lu 00 u- Of �m 2 LL 11 J m Q U 0 0 U 2 °d �D 7 m mr m= 11 SIDE A SIDE B CKT 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 BREAKER 20 20 20 20 20 20 20 20 20 1 1 20 20 20 1 50 50 OO O o 0 8 O a O a O d X r IV X Y fJ X r fJ z z z z w z z z z z 2-PDU CKT BREAKER SCHEDULE 1 - RACK ELEVATION O O O d d a O O O oo oo oD > X r IV m m z z z z z z z z z z NEW PDU RE: 2/A5.00 NEW RACK OVP (TYP. OF 2) NEW FIBER PATCH PANEL (TYP. OF 2) FUTURE CDIU (TYP. OF 2) (E) BBU AND FINGER TRAY, SHIFT DOWN AS REQUIRED FOR NEW EQUIPMENT AND ADD BCEM CARDS NEW BBU NEW FINGER TRAY (E) ENODE B (E) VERTICAL CABLE MGMT TOTAL BREAKERS = 20 OCCUPIED BREAKERS = 14 AVAILABLE BREAKERS = 6 NEW BREAKER EXISTING BREAKER NOTES: 1. CONTRACTORS TO PROVIDE CIRCUIT BREAKERS FOR OVP. 2. CONTRACTOR TO PROVIDE CIRCUIT BREAKERS & WIRING FOR NEW BBU. N.T.S. 3/4" = 1'-0" veria®nv' VERIZON WIRELESS SERVICES 3131 S. VAUGHN WAY, SUITE 550 AURORA, CO 80014 PROJECT INFORMATION SITE NAME CO3 ASPEN AIRPORT SITE I.D. 264 301 ASPEN AIRPORT BUSINESS CENTER ASPEN, CO 81611 CONSULTANT A 10/30/17 CONCEPT RSS B 11/06/17 RF COMMENTS RSS C 01/05/18 CLIENT COMMENTS RSS D 02/05/18 L.L. COMMENTS RSS E 03/01/18 CLIENT COMMENTS RSS 1st REVIEW SSB 2nd REVIEW KMS 5935 SOUTH ZANG STREET, SUITE 280 LITTLETON, COLORADO 80127 OFFICE: 303.932.9974 NOT FOR CONSTRUCTION RACK ELEVATION A5.00 U) z O Q w z w o_ U) z z zZ z z Lu w m W ¢z Lu z W X J w z z Lu Z LU z w Tu Lu J F U) m O U) U U Z ¢ (w_7 (D z 0 z Lu. U C7 Lu a J LU w d � O d O w Ir w m u- Of m 2 LL 11 veria®n,wl VERIZON WIRELESS SERVICES 3131 S. VAUGHN WAY, SUITE 550 AURORA, CO 80014 PROJECT INFORMATION SITE NAME CO3 ASPEN AIRPORT SITE I.D. 264 301 ASPEN AIRPORT BUSINESS CENTER ASPEN, CO 81611 CONSULTANT A 10/30/17 CONCEPTRSS B 1 1/06/1 7 RF COMMENTS RSS C 01/05/18 CLIENT COMMENTS RSS D 02/05/18 L.L. COMMENTS RSS E 03/01/18 CLIENT COMMENTS RSS 1st REVIEW SSB 2nd REVIEW KMS 5935 SOUTH ZANG STREET, SUITE 280 LITTLETON, COLORADO 80127 OFFICE: 303.932.9974 NOT FOR CONSTRUCTION GROUNDING SCHEMATIC A6.00 TYPICAL ANTENNA SECTOR GROUNDING NOTES KEY NOTES: 1) COPPER GROUND BAR OR APPROVED EQUAL, 1/4" x 4" X 12".HOLE 1. REFER TO VERIZON WIRELESS GROUNDING SPECIFICATIONS FOR ALL CENTERS TO MATCH NEMA DOUBLE LUG CONFIGURATION. GROUNDING REQUIREMENTS. 2) SPACERS AS REQUIRED 2. BOND AND GROUND ANY PROPOSED STRUCTURAL STEEL, CONCRETE 3) 5/8" LOCKW ASHERS ONLY NEEDED WHEN YOU ARE 4) WALL MOUNTING BRACKET _ c[ REINFORCING AND OTHER METALLIC BUILDING ELEMENTS, REFER TO VERIZON 5) 5/8" -11 H.H.C.S. BOLTS (VERIFY LENGTH) INSTALLING A NEW GROUND BAR RRH INTERNAL WIRELESS SPECIFICATIONS FOR EXACT REQUIREMENTS. 6) USE TAMPER RESISTANT MOUNTING HARDWARE z OVP GROUNDING KIT PER 3. THE ELECTRICAL CONTRACTOR SHALL PERFORM ALL BONDING AND GROUNDING MANUFACTURER TO THE SITE'S OUTER GROUNDING SYSTEM DURING THE CONSTRUCTION PHASE z SPECS. (TYP) OF THE BUILDING. O 4. CONTRACTOR IS TO CONDUCT FREQUENT INSPECTIONS DURING THE 5 GROUND OVP METAL CONSTRUCTION PHASE TO ENSURE THAT ALL GROUNDING ARRANGEMENTS ARE � MOUNTING STAND W/ MADE ACCORDING TO THE GROUNDING DESIGN SPECIFICATIONS. 5. DO NOT RETROFIT (OR UPGRADE) ESTABLISHED SITES THAT DO NOT MEET ALL THE REQUIREMENTS OF VERIZON WIRELESS GROUNDING STANDARD UNLESS n WEATHERPROOF KIT (TYP) THERE ARE DOCUMENTED OCCURRENCES OF EQUIPMENT DAMAGES AND/OR SERVICE AFFECTING CONDITIONS. PIPE GROUND CLAMP 6. USE ONLY VERIZON WIRELESS -APPROVED MATERIALS SUCH AS COPPER FOR O O MOST ELECTRICAL WORK AND ALUMINUM FOR CERTAIN APPLICATIONS FOR SITE O O O GROUNDING SYSTEM, ELECTRICAL PROTECTION COMPONENTS AND AC WIRING. O O O #6 THWN GREEN 7. USE THE SAME METAL THROUGHOUT THE GROUND SYSTEM WHEN POSSIBLE. O O O O O O INSULATED 8. IF DIFFERENT METALS MUST BE CONNECTED, BOND THEM BY EXOTHERMICALLY O O O O O 0 WELDING THEM TOGETHER. O O p p 0 9. USE TINNED COPPER WHEN CONNECTING TO GALVANIZED STEEL. O O 10. DO NOT BOND COPPER AND ALUMINUM TOGETHER UNLESS USING / O SPECIFICALLY DESIGNED EXOTHERMIC MATERIALS DESIGNED FOR THIS APPLICATION ARE USED OR A BIMETALLIC TRANSITIONAL CONNECTION IS O p O SECTOR GROUND BAR o 0 0 0 0 0 o :3/A6.00 UTILIZED. ° 0 0000000 0 ° 11. MAKE ALL BONDING ATTACHMENTS TO CLEAN, UNPAINTED METAL SURFACES OR USE APPROVED PAINT PIERCING WASHERS. 12. PAINTED SURFACES MUST BE SCRAPED, CLEANED, AND LIGHTLY COATED WITH THE APPLICABLE COMPOUND. 13. ALL INDOOR OR OUTDOOR POWER OR GROUNDING CONNECTIONS SHALL BE PROTECTED AGAINST CORROSION BY USE OF A THIN COATING OF ANTI - OXIDATION COMPOUND. A COPPER COSMOLINE GREASE BASED COMPOUND (NO NOTES: #2 AWG SOLID BTCW (TYP) OX -ID) SHALL BE USED ON ALL COPPER TO COPPER CONNECTIONS. A ZINC 1. THE DISTANCE BETWEEN COAXIAL CABLE SHIELD CIGBE BARS SHALL BASED (GREY COLORED) COMPOUND SHALL BE USED ON ALL COPPER TO STEEL NOT EXCEED 109. THIS MAY REQUIRE BONDING AT THE TOP, BOTTOM CONNECTIONS. WHERE OTHER COMPOUNDS SUCH AS KOPPER-SHIELD ETC AND TWO LOCATIONS IN THE MIDDLE OF THE TOWER FOR TALLER EXIST, THEY MAY BE'GRANDFATHERED' IN PLACE. PENTROX GREASE OR AN TOWERS. EACH RF CABLE SHIELD SHALL BE BONDED AT A MINIMUM OF ATTACH TO EXISTING BUILDING APPROVED EQUAL SHALL BE USED ON ALUMINUM CONNECTIONS. TWO (2) POINTS ON THE 14. DO NOT WELD GROUNDING CONDUCTORS TO THE STRUCTURAL MEMBERS OF TOWER (TOP AND BOTTOM). GROUNDING SYSTEM TOWERS, INCLUDING DOWN GUYS AND ANCHOR RODS. 15. BOND ALL METALLIC OBJECTS (SUCH AS WATER PIPES, CONDUITS, METAL FUEL 3 -GROUND BAR DETAIL N.T.S. TANKS WITHOUT CATHODIC PROTECTION, METAL FENCES, HVAC, ETC.) THAT ARE WITHIN 6 FEET (1.8 M) OF THE GROUND RING, OR FROM ANY OTHER ONLY NEEDED FOR NEW INTERIOR GROUNDED CONDUCTOR, TO GROUND RING OR TO THE GROUNDED MIN. #6 AWG BATTERY RACK EQUIPMENT RACKS CONDUCTOR. HARDWARE MIN. #6 AWG STRANDED STRANDED 16. ALL OUTDOOR HARDWARE (BOLTS, SCREWS, NUTS, WASHERS) SHALL BE 18-8 GREEN COPPER GREEN COPPER EQUIPMENT RACK STAINLESS STEEL TYPE GRADE. INDOORS, GRADE 5 STEEL HARDWARE MAY BE CONDUCTORS TO EACH CONDUCTOR TO USED. CHOOSE BOLT LENGTH TO ALLOW THE EXPOSURE OF AT LEAST TWO EQUIPMENT RACK (TYP INTERIOR HALO THREADS. (2) LEADS PER CABINET 17. WHEN BONDING TO A METALLIC OBJECT WHERE ACCESS IS LIMITED TO ONLY GROUND EQUIPMENT RACK ONE SURFACE, USE DRILLING & TAPPING OR SELF DRILLING SCREWS. DO NOT OR BATTERY CONNECTION USE SHEET METAL SCREWS. 18. ALL GROUNDING CONDUCTORS SHOULD PRESERVE A DOWNWARD TO COURSE AND BE AS STRAIGHT AS POSSIBLE AND AVOID SHARP Fl Fl TURNS.HORIZONTAL GROUND BAR o o #6 THWN GREEN 19. DO NOT USE U -SHAPED GROUNDING CONDUCTOR RUNS (U-TURNS IN THE AT EXTERIOR o o INSULATED WIRING) OR BONDING LAYOUTS TO REDUCE ARC -OVERS OF SHELTER 0 0 0 0 0 0 0 0 0 20. ALL GROUNDING CONDUCTS MUST BE RUN IN NONMETALLIC CONDUIT. ROUTE ONLY NEEDED WHEN ALL CONDUCTORS THROUGH NONMETALLIC SLEEVES WHEN PENETRATING YOU ARE INSTALLING GROUND BAR AT INTERIOR FLOORS, CEILINGS, AND WALLS. EQ NEW EQUIPMENT OF EQUIPMENT SHELTER EQUIPMENT 21. IF THE USE OF METALLIC CONDUIT CANNOT BE AVOIDED, BOND BOTH ENDS OF RACK CABINET RE: 2, & 000000000 THE CONDUIT TO THE GROUNDING CONDUCTOR BEING ROUTED THROUGH THE3/A6 o 0 CONDUIT MIN.#2 AWG o 0000000 0 22. KEEP LENGTHS OF CONDUCTORS TO A MINIMUM SOLID BTCW 23. USE MULTIPLE CONDUCTING PATHS. PARALLEL PATHS ARE ONLY DESIRABLE #2 AWG SOLID BTCW (TYP) WHEN SENSITIVE ELECTRONIC EQUIPMENT IS NOT PART OF THE CONDUCTOR GROUND �. PATH 24. KEEP BENDS IN CONDUCTORS TO A MINIMUM. NOTES: RING 25. THE MINIMUM INSIDE BENDING RADIUS IS: 1. VERIFY EXISTING INTERIOR GROUNDING IS SUFFICIENT FOR NEW EQUIPMENT A. 6 INCHES (0.15M) FOR CONDUCTORS UP TO #6 GAUGE. INSTALLATION AND GROUND ALL NEW INSTALLED EQUIPMENT AS REQUIRED BY VERIZON B. 12 INCHES (0.3M) FOR CONDUCTORS #6 TO #4/0 GAUGE. WIRELESS STANDARDS C. 24 INCHES (0.6M) FOR CONDUCTORS #4/0 GAUGE AND LARGER 2. CONNECT THE EQUIPMENT FRAMES TO THE MGB/FGB, USING A MINIMUM OF #6 AWG 26. GROUND CONDUCTORS MUST NEVER BE ENCIRCLED WITH FERROUS METAL STRANDED COPPER, GREEN -INSULATED CONDUCTOR. TO ASSURE A GOOD CLAMPS, PLACED THROUGH METAL WALLS, METAL PLATES, OR SHORT CONNECTION AT THE FRAME, CLEAN THE CONNECTION POINT ON THE FRAME TO BARE ATTACH TO EXISTING BUILDING SECTIONS OF METAL CONDUIT, AND MUST NEVER BE PLACE IN THE SAME CABLE METAL, APPLY GROUNDING SYSTEM RACK AS DC POWER CABLES, HIGH FREQUENCY CABLES, ETC. AN ANTI -OXIDATION COMPOUND, AND CONNECT USING A TWO -HOLE, LONG -BARREL 27. WHEN ATTACHING PVC CONDUITS TO ANY SURFACE UTILIZE NONCONDUCTIVE COMPRESSION LUG. SOME EXISTING SITES MAY BE USING SINGLE HOLE LUGS FOR FASTENERS OR NONFERROUS FASTENERS ONLY. THESE PURPOSES. THESE CONNECTIONS SHOULD NOT BE REPLACED "IF" THE RUNS 28. IF CONNECTIONS BETWEEN ALUMINUM CONDUCTORS AND STEEL OBJECTS ARE TO SHORT AND THERE IS NO LIKELIHOOD OF MECHANICAL STRESS ON THE CABLE MUST BE MADE, TINNED LUGS AND PENTROX SHALL BE USED. WHERE THERE THAT WOULD LOOSEN THESE CONNECTIONS. COMPRESSION TYPE NOTE: ARE CONCERNS THAT THE PENTROX MAY NOT PROVIDE ADEQUATE 3. DC DISTRIBUTION PANELS, CHASSIS, BATTERY RACKS, FRAMES AND CHASSIS OF CONNECTION GROUNDING SCHEMATIC IS DIAGRAMMATIC INTERFACING, THEN A BIMETAL SPLICE BETWEEN THE ALUMINUM CONDUCTOR RECTIFIERS AND RECTIFIERS SHOULD BE BONDED DIRECTLY TO THE MGB/FGB. WHEN AND DOES NOT REFLECT ACTUAL EQUIPMENT AND A SHORT LENGTH OF COPPER CONDUCTOR MAY BE USED. UTILIZING AN INTEGRATED DC/DC CONVERTER SYSTEM, THE 48 -VOLT RETURN EXOTHERMIC WELD LAYOUT ORIENTATION. REFER TO PLANS FOR 29. ALL OF THE BONDING AND GROUNDING CONDUCTORS SPECIFIED FOR ROOFTOP DISTRIBUTION BAR SHALL BE BONDED TO THE 24 -VOLT RETURN DISTRIBUTION BAR WITH DIRECTION. CELL AND MICROWAVE SYSTEMS IS BARE WIRE. INSULATED WIRE SHALL NOT BE A MINIMUM CONDUCTOR SIZE OF A #2, STRANDED COPPER CONDUCTOR, IN A WIRELESS SPECIFIED OR SUBSTITUTED FOR THE BONDING AND GROUNDING CONDUCTORS SHELTER WITH A DEDICATED 48 -VOLT PLANT, THE 48 -VOLT RETURN DISTRIBUTION BAR OF ROOFTOP INSTALLATIONS. SHALL BE BONDED TO THE MGB. ALL BATTERY FRAMES SHALL BE BONDED TO THE MGB WITH A #6 GREEN THWN INSULATED CONDUCTOR. (ONLY APPLICABLE WHEN MODIFICATIONS ARE REQUIRED TO THE BATTERY OR POWER PLANT.) 4. VERIFY (E) SYSTEM IS PER ATTACHED NOTES AND DETAILS AND IF NOT NOTIFY P.M. FOR REQUIRED UPGRADES. 4 -GROUNDING NOTES 2 - INTERIOR GROUNDING N.T.S. 1 -GROUNDING SCHEMATIC N.T.S. veria®n,wl VERIZON WIRELESS SERVICES 3131 S. VAUGHN WAY, SUITE 550 AURORA, CO 80014 PROJECT INFORMATION SITE NAME CO3 ASPEN AIRPORT SITE I.D. 264 301 ASPEN AIRPORT BUSINESS CENTER ASPEN, CO 81611 CONSULTANT A 10/30/17 CONCEPTRSS B 1 1/06/1 7 RF COMMENTS RSS C 01/05/18 CLIENT COMMENTS RSS D 02/05/18 L.L. COMMENTS RSS E 03/01/18 CLIENT COMMENTS RSS 1st REVIEW SSB 2nd REVIEW KMS 5935 SOUTH ZANG STREET, SUITE 280 LITTLETON, COLORADO 80127 OFFICE: 303.932.9974 NOT FOR CONSTRUCTION GROUNDING SCHEMATIC A6.00 PUBLIC NOTICE RE: Burkholder Investments LTD/Verizon Wireless Special Review for a Wireless Communications Facility (CASE# P048-18; PID 2643-344-05-053) NOTICE IS HEREBY GIVEN that a public hearing will be held on Wednesday, August 8, 2018 at a regular meeting to begin at 12:00 PM or as soon thereafter as the conduct of business allows, before the Board of County Commissioners, BOCC Meeting Room, 530 East Main Street, 1St Floor, Aspen to consider an application submitted by Verizon Wireless LLC (Colleen Nebel, Black & Veatch, 4600 S. Syracuse St. Denver, CO 80237) requesting Special Review approval to upgrade and expand the existing wireless antennas. The property is owned by Burkholder Investments Ltd, is located at 301 AABC, and is legally described as Lot 3, Block 5 Filing 1, Aspen Airport Business Center. The State Parcel Identification for this property is 2643-344-05-053. The application/resolution are available for public inspection in the Community Development Department, City Hall, 130 S. Galena St., Aspen CO 81611. For further information, contact Michael Kraemer at (970) 920-5482. Jeanette Jones, Deputy County Clerk Board of County Commissioners Published in the Aspen Times Weekly on July 5, 2018. Attention Applicant/Representative: It is your responsibility to do the following: 1. Mail this Public Notice to all property owners and mineral estate owners within 300' of the subject property at least 30 days prior to the hearing with the return address of the Community Development Department. The names and addresses shall be those on the current tax records of Pitkin County as they appeared no more than 60 days prior to the date of the public hearing. 2. Submit the Affidavit of Notice by Posting & Mailing (previously sent to you with your applicant letter) as proof of compliance with the Code at the hearing. 3. Pick up Public Notice sign from the Pitkin County Community Development Department, 130 South Galena Street, Aspen, CO (970) 920-5526. 4. Post the Public Notice sign on the property at least fifteen days (15) prior to the hearing. 5. Remove the Public Notice sign within one week after hearing date. 7- 9 a G o C/] O Z O O O ►�f `e �C rb CD �x S 'CJ. � C7 w < >y O � O C-1 ] C7 C O � O � N O'er > o D Gz'a C c�D w, a1 301 ABC — Affidavit of Notice (Verizon - CO3 Apsen Airport).pdf 1 OV CD W N b `ti CG E� C p^ �•G T � (7• f7• O C O CD � W G n• n• a W CD O _Z n n O 0- `J CD r+ CD y CL O. O u C1q CCD O O lv CD r* (D cn O O n 0 0 cn O as ° CD (D C) o 0 CD UQ.� �'w .t 0. T CD CD .Z 0. CSD UQ (D p CD p F p CD a CD °O CD lc� a, C-11 O O (7 h CCD CSD O CCD CD (D O' p_+ a D O N CD D O F�- (mN (�D O¢7T' p rD 7 �C O O < O. `G p p a CD C'D O O � � O O' y � �•n 'J .�. CD CD wJC—D :z' O M N o CD cn `* CD ° CD �, o o CD CD•omaICD CD o ° Cl m ° o= cm '- .o •, CP ° r�i ❑ to �. cr O cn ° vi c �° CD CCD 8/7/2018 12:40:26 PM O O O ►�f CD 0 0 COD � C7 w < >y O � C-1 ] C7 C O � O � N �z�d o D Gz'a C c�D w, H�Cy py�Oil Nrzo o� � T°° oz � �C) oodOC�7 C CD CD v�o n aCDo CD W c a ❑ w � o' 0 8/7/2018 12:40:26 PM Wd£S:ObZL 8LOZ/L/8 � Z)pd•(uodnVuasdV£pD-uozuaA)a�i;oNJo;inepiJ)V—DSVLOE L ■■■ 0 ■■■■■W 1 Gid17oGi� C'Z� C'Z� Z o cD o o O O CD Q P7- CD 00 NCD y�i�•UJ CDcn CCD n CL CD CL CDCD N O CD � DCD i n CD o n o Z CDCD p CD Z CD CD Z Ocr CD CD 00 C M$ CD CCD W'CDP. 00 CD CD Cnr CD pp p N n CD CD z `r .+. CD ¢ O C �d P n- P-. z O CL ID .Z CDD (7 W CD CD w ; O P- m 0 CD � � 0 N CD CD O o' r -L n Q M• O UDCD v �C CCD C/1 p --h n d� CI. AO N C w 00 CD' CD "! Z N N (') '( � � O rL CD 00 x � PD W O� y CD CD CD W CD C CD CD CD d 11 CD Zr C d pa � "� N • ►S p Ur ` N CD CD O O C O A CDCD '.��CD ¢ CD CD Q. cnn b c �. C0 N !D IDZY, cr0.� cn CD A a > O CD C � CD - A A un CD CD , CD CD CD O Q A� �t [7 NA A C\ CD O CD cro CDD .o CD Yz CD �• n �• A D CD o CDCD a 11 D D N = D W D 4:�- p -10 O n vi -i :E -0O D w n Ln v) o r v) N cn o Ln o D = z n D o O O v) o D W D N p a N m v A w n v w z r yNN Zy* N N A rnN D O W O w :)o -0m m m m m DO O O com m W F co W W m D W m W z O Ln Z O D D m � D D XV)m m Z O 70 D n n D D � D p p W O W O z XD zco m z m G) O D O o O 00 00 00 D 00 D m m 00 D 00 OD z oi D rn 0) L=m m rn m ZZ X m n D m N m D m mO nAp O Ln N Z m O Z 00F- o R0 00 m 00 Z M m 0)N Ol a 2 N 0 ;)o � N D Ol 2 N n O D r W w cn w 70 u' D w _ r m D n z 00 2 p Z < p Z N W n m n r 0 n >-> W D W v N p D v Ln O Dn m Z O oo N O W O N z z m n 2 m O m m N mr cD i, v m Z O 00 N a) O w m D n W 22Z p m O 2 z L/) -own m n0 ao N rn O C Ln Ln a --j� N0 D � W m � .i m -0'7 -0V m W O m to mz z m p m z m W m Z W O r p z* Z Z r Z D Z D m O Z Z O n x E n � D n D n -0n D r n K OOpO00 Oo 0o w O oOAnN O > n n O O � 00 "'=ao z aoLO 00 D �' N Oo o N N a) rn m N Nw rn A -zi m p z O N p N 70 �"' 7m0 O m 70 Z l0 V) Z GDl r m al m m r 2 W O n C n 0 n >-> W D W v N p D v cDii O m co Z O O t1Oo N Oi O z > p 00 Z m Z O oo N O W O N z z m n 2 m O m m N mr cD i, v m Z O 00 N a) O w m D n W 22Z p m O 2 z L/) -own m n0 ao N rn O m D 00 n co A 0 00 = z m _ D L/I v m Z n O Oi o 00 D D W n n p T z n w D w m .i m -0 w r m m p m m co O � m m W r Z D Z D m O Z D A D n D O n D z -0n D r n D D n 0o n 0 co p � n D W D W v N p D W m rn 2 cn o n cn O n D to p cn o n p T z n w w m .i D -0 w r m m W m m co O p0 m m W r Z D Z D m O Z D A D n D o n D z -0n D r n D n 0o n 0 co O > n > n D O � n O 00 00 00 00 �' N Oo N 2 O O N m �"' 7m0 O m Z Z l0 V) m m al m 2 2 W O C C r r N m m O -< -< o v O -j D N D W D N D n v p = Z r ^' o n„ m O r D D D m z C w Z n O z O = m N v m Z n rn N D W n 7z = p G)rn n � m z n N ow m > D n n co 70 p m = m D m z n rn N LQ w p D W n D D n N N O z � L/) n D 0700 O Z p m p W w O D co r O X D v Z o p m V)w p T z n m r D rn z D to m D � D D N> V) N m N N 70 (/) I D N N m m -V n V) O G) 00 O z N N m m n O 00 N -1 LnD O Z m Z m z m n O 00 N L/I O Z m > D m n O 00 N O D LnO 2 O z Z N -00 z n O 00 ~' O C D r N D G) z O cn > z D m C r r z O r m = T N D Ln O r Z — m r m to -0 m Z n O 00 N rn N N N D Ln G7 O p p z O Z m Z T m L/)N -0N m Z n O 00 N rn N N D Ln O r Z � N N O A N D (A G7 Q r Z Z cn -0D m Z n O 00 N N N O m O u, O V z 7 D D D O Q p m m n O 00 � O m O N O rn D x O D Z v, C D Z �n -0 m Z n O 00 N N N N D cn O O z m — O m n 00 D O �o O w O D m G)D D w m D w D D N> 2 D N 2 D N -0 m Z n O 00 Ol N N N 2 V) Q v Z O n 1 O v 0000 0, rV _ D D Or O O m a l/) Z n O 00 N O D Ln G) O Z D X z n0 m m V) z n O 00 N N D V) G) O z = D 0 70 M : N -0 z n O 00 N o D L G) O zz N D D v, D m D N -0 z n O 00 N o D � G) Q O m > C r N -00 z n O 00 ~' O C D r N D G) z O cn > z D m C r r z O r m = T N D Ln O r Z — m r m to -0 m Z n O 00 N rn N N N D Ln G7 O p p z O Z m Z T m L/)N -0N m Z n O 00 N rn N N D Ln O r Z � N N O N -0N m z n O 00 N rn N N N D (A G7 Q r Z O m N = O K D cn cn -0D m Z n O 00 N N N O m O u, O V z 7 D D D O Q p m m n O 00 � O m O N O rn D x O D Z v, C D Z �n -0 m Z n O 00 N N N 00 N D � G) Q r Z D cn O O z m L/) - m Z n O oo N rn N O m n 00 D O �o O w O D rn 00 D Ln m D Lrl D D A C D AD x C r m m r r D O D N -0 m Z n O 00 Ol N N w 2 D v E:* N -0 m Z n O 00 N v n D ry m D - p a N m Z D n L,) O n 00 Q N rn r N Z N C = D LI) m � z p 70 v) -0 m Z n O ao N rn N N N N D vN) G1 O r Z g rev N C r r z O r m L/)N m m Z n O 00 N rn N N N D Ln O r Z — m r m to -0 m Z n O 00 N rn N N N D Ln G7 O p p z O Z m Z T m L/)N -0N m Z n O 00 N rn N N D Ln O r Z � N D r N r D C m Z r N -0N m z n O 00 N rn N N N D (A G7 Q r Z O m N = O K D cn cn -0D m Z n O 00 N N N O m O u, O V z 7 D D D O Q p m m n O 00 � O m O N O rn D x O D Z v, C D Z �n -0 m Z n O 00 N N N 00 N D � G) Q r Z D cn O O z m L/) - m Z n O oo N rn N O m n 00 D O �o O w O 90 to x >CY) N m -0 zD cn O 00 O N Z 00 It m D Z D D Z T D x _ 7K > > -0 m z O oo a N m O -0 D V) O r Z D 2 Z D r -0 m z O 00 0 N N O - D cn O r Z m D :)o O p < p D In -a m z n O 00 � Lrn F -A O -0 D cn to O r Z r -< Z 7Z 2 DLr)p D D Ln -0 m z n O 00 C N A N N - D cn O r Z x C r m m r r D O D N -0 m Z n O 00 Ol N N w NN N -0 D N to O r Z w N 2 F_ N r D z p m 70 D p O D -0 m Z n O 00 a) N w N O D cn Ln O r Z r D —1 2 D X D Z N -0 m Z n O 00 N w F O - D N cn O r Z E:D � O z r D (n m Z n O 00 rn N N N F N D Ln Ln ) O r Z G) CDi) m m `p = Z D N -0N m z n O 00 M N N N < F C Ca D C N cn n O 90 r Z m m cn D 90 x m Z D D v m Z LnC Z m V) Ln D 7z z m O r r n N N p N N O N N z z Z l� On v V)i � G7 Z n O >Z L/)Z � z m D m r n O(,) > W N z m 00 O m �o 00 N O r Z m m 00 rn O D r z Z = N V D Z N J N � N C � N N � NN z z n O 00 N D N C) O m m O r p Ln -0 n O 00 F-� N D Ln (j) O D D n ;,K N z n O 00 No D C N 0 O D Gl r Z co z m Nrn D G) m Q) N r Z � z m D m r Gl N r X Z m N n N N Z V r N N Z N"o O 00 -j n r- 0 Ln -0 N O � O N -0 F-' D O (/) z l7 O 0 m 7o p O p co z m Nrn D G) m Z n O 00 D � G) O r � z m D m r Z n O 00 M D N 6) r- 00 O r D v O n Z n 4t PITKIN COUNTY COMMUNITY DEVELOPMENT DEPARTMENT 130 S. Galena Street Aspen, Colorado 81611 (970) 920-5526 FAX # (970) 920-5439 June 28, 2018 Colleen Nebel 4600 S Syracuse Street Denver, CO 80237 nebelc@bv.com Re: Burkholder Investments LTD Special Review for a Wireless Communications Facility (PID 2643-344-05-053; Case P048-18) Dear Ms. Nebel: The Planning Office has completed its preliminary review of the captioned application. We have determined that this application is complete. After a more detailed review of the submittal information, additional information specific to the application may be requested in order to adequately review and process the application. The planner in charge of the review will request the information from you directly. We have scheduled this application for review at a public hearing by the Board of County Commissioners on Wednesday, August 8, 2018 at a meeting to begin at 12:00 P.M. in the BOCC Meeting Room, 530 East Main Street, 1St Floor, Aspen. Should this date be inconvenient for you, please contact me within 3 working days of the date of this letter. After that the agenda date will be considered final and changes to the schedule or tabling of the application will only be allowed for unavoidable technical problems. The Friday before the meeting date, we will call to inform you that a copy of the memo pertaining to the application is available at the Planning Office. Please note that it is your responsibility to post a public notice sign on the property at least fifteen days prior to the hearing (and remove it within one week after) and to mail notice to all property owners and mineral estate owners within 300' of the subject property at least 30 days prior to the hearing with the return address of the Community Development Department (copy of notice will be sent to you by the Community Development Department). The names and addresses shall be those on the current tax records of Pitkin County as they appeared no more than 60 days prior to the date of the public hearing. Please submit the enclosed Affidavit of Notice by Posting & Mailing as proof of compliance with the Code at the hearing. If you have any questions, please call Mike Kraemer, the planner assigned to your case, at 920- 55482. Sincerely, Bonnie Shiles Administrative Assistant Encl: Affidavit of Notice (Code Section 2-20-100) 19. 10_"11►[K1111'"", COMMUNITY DEVELOPMENT DEPARTMENT 130 South Galena Street Aspen, Colorado 81611 Phone (970) 920-5526 FAX (970) 920-5439 MEMORANDUM TO: Aspen Fire Department Pitkin County Attorney Aspen Airport Business Center (AABC) FROM: Mike Kraemer, Community Development Department Michael.kraemer&pitkincount. RE: Burkholder Investments LTD Special Review for a Wireless Communications Facility (CASE P048-18; PID 2643-344-05-053) DATE: June 28, 2018 Attached for your review are materials for an application submitted by Burkholder Investments LTD. The Board of County Commissioners will review the application on Wednesday, August 8, 2018. Please return your comments to me by Friday, July 27, 2018. hLtp://pitkincounly.com/DocumentCenterNiew/ 165 5 8 Thank you. PITKIN COUNTY COMMUNITY DEVELOPMENT Permit Receipt RECEIPT NUMBER 00044385 Name: Black & Veatch Corporation Date:6/20/2018 Project Address: 301 AABC Type: check # 65271168 Permit Number Fee Description Amount 0048.2018.PLAN PP- Flat Fee 1,625.00 0048.2018.PLAN PP- Clerk Fee 375.00 0048.2018.PLAN PP- Public Notice Fee 54.00 Total: 2,054.00