HomeMy WebLinkAboutpitkin.eh.264916101008 (2017)Page | 1
Pitkin County Environmental Health Department
Onsite Wastewater Treatment System (OWTS) USE PERMIT
Permit for Continued Use of an Existing OWTS
76 Service Center Road, Aspen, CO 81611
Phone: 970-920-5070 Fax: 970-920-5374
www.aspenpitkin.com/EHNR
Parcel ID #: 2649-161-01-008
OWTS Use Permit #: 0045.2017.POWU
Date Issued: 7/17/2017
Issued By: Bryan Daugherty
Expiration Date: 7/17/18
Owner(s): Carl and Vickie Smith
Property Address: 208 Crystal Circle
Legal Description: Lot 34, Block 2, Crystal River Country Estates
Licensed Inspector: Carla Ostberg
Inspection Date(s): 6/5/17
SYSTEM INFORMATION
Components Type Capacity/Size
Primary Treatment Unit Concrete two-compartment tank 1500 Gallons
Secondary Treatment Unit
Absorption Area Gravelless chamber bed 1039 ft2
Other System Components
OWTS Use Status:
In use at the time of the inspection. Not in use at the time of the inspection.*
*If the OWTS was not in use at the time of the inspection, it is recommended that the system be re-evaluated when it is in use for a more accurate
evaluation of the system.
System Records:
Permit #: 01021 Date of Issuance: 5/1/01 Date of Final Approval: 7/16/02
# of Bedrooms or fixtures served by OWTS: System is designed to serve 3 bedrooms.
Operational Status: After repairs were made to the inlet tee in the tank, the system was functioning as designed. The
field area did not show any signs of failure.
Inspector Recommendations: Annual maintenance or as needed.
Department Recommendations: N/A
Issuance of this OWTS Use Permit is based solely on the conditions observed and reported by the inspector to the Department on the date of the inspection(s) and
on Department records at the time of permitting. The issuance of this permit does not constitute a guarantee, warranty, or representation by the Department
that the system will operate properly or will not fail or that the system will not be subject to future enforcement action to correct non-compliant conditions.
Estimated capacity of the system has been listed on the permit and we recommend that you monitor and/or meter water use to prevent overuse and possible
failure.
CBO Inc.
33 Four Wheel Drive Road
Carbondale, CO 81623
cell) 970-309-5259 office) 970-704-0484
carla.ostberg@gmail.com
July 10, 2017
Kurt Dahl
Pitkin County Environmental Health Department
Kurt.dahl@pitkincounty.com
Onsite Wastewater Treatment System (OWTS) Use Permit Inspection – Verified Repairs
208 Crystal Circle
Pitkin County, Colorado
Kurt,
This letter is verification that the septic tank was pumped by Altitude Septic on June 29, 2017. At the time
of pumping, they were able to verify that the pipe entering the septic tank without a tee that we observed
during our inspection was NOT the inlet pipe. The inlet pipe, including the tee, was tucked under the lid
and entered the side of the septic tank. At the time of pumping, Altitude Septic also cleaned the effluent
filter and added an extension handle for easier access.
Please call with questions.
Sincerely,
Carla Ostberg, MPH, REHS
NAWT Certified Inspector
Certification # 11044ITC Exp. April 2018
Inlet tee handle extension on filter
CBO Inc.
33 Four Wheel Drive Road
Carbondale, CO 81623
cell) 970-309-5259 office) 970-704-0484
carla.ostberg@gmail.com
June 12, 2017
Jeff Kelley
jeff@riverstonereal.com
Onsite Wastewater Treatment System (OWTS) Use Permit Inspection
208 Crystal Circle
Pitkin County, Colorado
Jeff,
As requested, CBO Inc. performed an Onsite W astewater Treatment System (OWTS) Use Permit
inspection at 208 Crystal Circle, Carbondale, Colorado on June 5, 2017. The legal description of the 1.0-
acre property is Lot 34, Block 2, Crystal River Park Subdivision.
The permit and record drawing was provided by Pitkin County Environmental Health Department (Parcel
ID #2649-161-01-008). The subject OWTS consists of one 1500-gallon, two-compartment concrete
septic tank. Effluent gravity flows to six rows of 12 ‘Standard’ Infiltrator chambers for a total of 1350
square feet of infiltrative area. Individual Sewage Disposal System Permit 01021 documents this system.
The system was sized to accommodate 3 bedrooms. The permit received final approval July 16,
2002.
A clean out was located near the northeast corner of the residence. The septic tank was just beyond the
planters under a railroad tie walkway that need to be removed in order to access the septic tank lids.
Both manhole lids of the septic tank we accessible once the railroad ties were removed with 2-feet of
risers on the inlet side of the septic tank and 1.5-feet of risers on the outlet side of the septic tank. The
inlet tee is missing, and the outlet tee is present with an effluent filter. The inlet tee must be replaced.
We recommend adding a handle extension on the outlet tee so the filter is more easily accessible for
future cleaning.
We measured approximately 1-inch of scum on the inlet side of the septic tank over suspended sludge as
the septic tank is in use. We measured approximately 4-inches of sludge on the outlet side of the septic
tank. While the septic tank does not need to be pumped at this time, it may be pumped as part of the
buyer’s contract. Depending on the timeframe of the sale, we can re-evaluate the level of solids in the
septic tank at that time. We also recommend repairs to the inlet tee be made when the septic tank is
pumped below the level of the tee.
A clean out was present between the septic tank and the soil treatment area (STA). Inspection ports
were present in four corners of the STA. There was approximately 4-inches of standing water the
southeast inspection port. According to the drawing provided by Pitkin County, effluent enters the
manifold closest to this chamber. All other inspection ports were dry. The inspection ports extend as
deep as 8-feet below grade. We walked the STA and found no evidence of surface saturation or failure
at the time of our inspection. This evaluation is not a guarantee of future system performance. This
inspection is good for one year.
Required Repairs:
• Install inlet tee.
Recommendations:
• Clean effluent filter annually, or as needed.
• Add handle extension on effluent filter.
This report and a completed OWTS Use Permit Application must be submitted to the Pitkin County
Environmental Health Department. Applications may be submitted to Pitkin County Environmental Health
Department electronically. The following are links to the required OWTS Use Permit Application and
Checklist.
Application: http://www.pitkincounty.com/DocumentCenter/Home/View/621
Application Checklist: http://www.pitkincounty.com/DocumentCenter/Home/View/620
All questions regarding permit submission can be directed to Pitkin County Environmental Health
Department, 970-920-5070.
Disclaimer: This inspection is intended only as an evaluation of the present condition of the OWTS
based upon what was observed and the Licensed Inspector’s expertise in onsite wastewater technology.
The Inspector has not been retained to warrant or guarantee the proper functioning of the system for any
period of time in the future. Because of numerous factors which may affect the operation of an OWTS,
as well as the inability of the Inspector to supervise or monitor the use or maintenance of this OWTS, this
report shall not be construed as a warranty by the Inspector that the system will function properly for any
particular prospective buyer, and the Inspector disclaims any warranty, either expressed or implied,
arising from the inspection of the OWTS or this report. The evaluation does not ascertain the impact the
system is having on groundwater.
Please call with questions.
Sincerely,
Carla Ostberg, MPH, REHS
NAWT Certified Inspector
Certification # 11044ITC Exp. April 2018
Clean out near northeast corner of residence
View of septic tank lids under railroad ties
Inlet tee missing Outlet tee with effluent filter (recommend handle extension)
STA Inspection ports under boxes
View of STA, looking southwest
Clean out on sewer line between septic tank and STA
INVOICE
Date
6/27/2017
Invoice #
1370
Bill To
208 Crystal Circle
Altitude Septic, LLC
PO Box 1534
Eagle, CO 81631
Total
Balance Due
Payments/Credits
970-471-0913
AltitudeSeptic@gmail.com
AltitudeSeptic.com
Due Date
Due upon receipt
DescriptionQuantity Unit Price Amount
Dump Fee1,500 0.20 300.00
Pump Fee1,500 0.23 345.00
Handle for filter1 10.00 10.00
Any balance not paid in 30 days will incur a 3% interest charge.$655.00