HomeMy WebLinkAboutpitkin.eh.264321307006 (2019) ONSITE WASTEWATER TREATMENT SYSTEM (OWTS) CONSTRUCTION PERMIT 76 Service Center Rd· Aspen, CO · 81611 Phone: 970.920.5070 Fax: 970.920.5374 Permit #: 0010.2019.POWT Parcel ID #: 2643-213-07-006 Permit Issued: NEW REPAIR REMODEL/ADDITION TANK ONLY FIELD ONLY AMENDMENT Owner(s): Kurt Adam Property Address: 450 Solar Way Legal Description: Size of Lot: 2.734 Acres Detached Accessory Unit: YES NO Size of Building: Sq. Ft. Size of Accessory Unit: Sq. Ft. This system will serve 3 bedrooms, original permit (87025) was designed to serve 3 bedrooms Designed By: All Service Septic Project #: N/A Dated: 4/29/19 Phone #: Mailing Address: Fax #: Email Address: Carla.Ostberg@gmail.com Perc Rate: Profile Hole Depth: Depth to Groundwater or Bedrock:  Minimum Tank Capacity: N/A Minimum Absorption Area: N/A Permit Conditions: This OWTS Construction Permit is approved on the condition of compliance with the engineer design as submitted with the application and the specifications cited above. Changes must be approved by this Department and the engineer prior to construction. As a result of a Use Permit Inspection it was found that the existing dosing chamber is no longer in functional condition and must be replaced. The existing dosing chamber must be pumped of effluent prior to being removed or crushed in place. A new “IM-540 Infiltrator Poly Tank” will be installed with a dosing siphon to dose the existing field area with approximately 95 gallons per dose. This Permit must be kept on-site during installation. The engineer must do a final inspection of the installation and submit an "as -built" letter to this Department within 30 days of the final inspection, unless a longer period of time has been agreed upon, in writing. This Department must also be called for the final inspection with a minimum of 48 hours notice. Minimum horizontal distances between components of the system and physical features shall conform to the requirements of the Pitkin County OWTS Regulation. This Permit is conditioned upon the property owner(s) providing for regular inspection, cleaning, and maintenance of the syst em by qualified personnel, in accordance with the manufacturer's recommendations and the requirements of the Pitkin County OWTS Regulation. Issuance of this OWTS Construction Permit does not constitute a guarantee, warranty, or representation by the Department that the system will operate properly or will not fail. Issuance of this permit does not imply compliance with Pitkin County building and/or land use regulations, nor guarantee issuance of building and/or land use permits. THIS PERMIT IS EXPRESSLY CONDITIONED UPON COMPLIANCE WITH ALL REQUIREMENTS OF THE PITKIN COUNTY OWTS REGULATION, INCLUDING BUT NOT LIMITED TO THOSE CONDITIONS SPECIFIED ABOVE. Plans and specifications for the proposed OWTS have been reviewed and are considered satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated in accordance with the Pitkin County OWTS Regulation. This Permit will expire 1 year from the date of issuance unless construction on the system has commenced. An "as-built" drawing must be submitted and approved by EH before final approval of the system will be issued. Issued By: Bryan Daugherty, REHS Date: 5/6/19 Expires: 11/6/19 Installer: License #: Reactivation Authorized by: Final Approval Issued By: Date: New Expiration Date: EH Altitude Septic, LLC Bryan Daugherty, REHS 5/14/19 53 4/30/2019 Pitkin County Mail - Online Form Submittal: Septic (OWTS) Construction/Repair Permit Application https://mail.google.com/mail/u/0?ik=c2c72bb885&view=pt&search=all&permmsgid=msg-f%3A1632202677817473239&simpl=msg-f%3A16322026778…1/3 Bryan Daugherty <bryan.daugherty@pitkincounty.com> Online Form Submittal: Septic (OWTS) Construction/Repair Permit Application noreply@civicplus.com <noreply@civicplus.com>Mon, Apr 29, 2019 at 8:02 PM To: schuyler.clay@pitkincounty.com, ehapps@pitkincounty.com Septic (OWTS) Construction/Repair Permit Application Job Parcel ID 264321307006 Physical Address 450 Solar Way System Type OWTS (Septic) Type of Permit Existing System Repair Application Residences 1 Repair Type Tank Only No. of Bedrooms 3 Lot 6 Block 3 Filing 1 Subdivision Brush Creek Village Is this a multi-family structure? No Lot Size 2.734 Living Area Square Footage 3407 (Section Break) Uploads Site Plan septic site plan.jpeg Building Floor Plans dosing tank 3.jpg System Design dosing tank system design.jpeg Additional Reports, etc.Field not completed. (Section Break) Primary Contact Information Primary Contact First Name Kurt Primary Contact Last Name Adam 4/30/2019 Pitkin County Mail - Online Form Submittal: Septic (OWTS) Construction/Repair Permit Application https://mail.google.com/mail/u/0?ik=c2c72bb885&view=pt&search=all&permmsgid=msg-f%3A1632202677817473239&simpl=msg-f%3A16322026778…2/3 (Or Company Name) Primary Contact Email Address kurt_adam@comcast.net Primary Contact Address PO BOX 607 Primary Contact Phone Number 970-923-6970 Primary Contact City Aspen Primary Contact State Colorado Primary Contact Zip 81612 (Section Break) Primary Contact Information (If other than Owner) Primary Contact is Owner?Yes Indicate Preferred Method of Payment Debit/Credit Card Payment Contact Email for Debit/Credit Payment kurt_adam@comcast.net (Section Break) Designer Information Primary Contact is Designer?No Designer First Name Carla Designer Last Name Ostberg Designer Phone Number 9707040484 Designer Email Address carla.ostberg@gmail.com Designer Mailing Address 33 Four Wheel Drive Road Designer City Carbondale Designer State CO Designer Zip 81623 (Section Break) PLEASE READ BEFORE SELECTING SUBMIT: By selecting SUBMIT, I certify that I am the owner or representative with the legal authority to agree to the conditions of this permit, the above information is complete and accurate, and that I have provided complete and accurate information in all of the documents included in my application package. I acknowledge that this department may revoke any permit I am issued if my application is found to contain any inaccurate, false, or misleading information. Building Permit Instructions 4/30/2019 Pitkin County Mail - Online Form Submittal: Septic (OWTS) Construction/Repair Permit Application https://mail.google.com/mail/u/0?ik=c2c72bb885&view=pt&search=all&permmsgid=msg-f%3A1632202677817473239&simpl=msg-f%3A16322026778…3/3 If this application is part of a building permit application, please bring a copy of this application to your building Pre-Submittal meeting. To get a copy, either enter your email address to receive a copy of your application, or select "Submit and Print" below. Email not displaying correctly? View it in your browser. CBO Inc. 33 Four Wheel Drive Road Carbondale, CO 81623 cell) 970-309-5259 office) 970-704-0484 carla.ostberg@gmail.com April 29, 2019 Kurt and Trish Adam trishadam@comcast.net Onsite Wastewater Treatment System (OWTS) Use Permit Inspection 450 Solar Way Pitkin County, Colorado Kurt and Trish, As requested, CBO Inc. performed an Onsite W astewater Treatment System (OWTS) Use Permit inspection at 450 Solar Way, Aspen, Colorado on April 10 and April 17, 2019. The legal description of the 2.734-acre property is Lot 6, Block 3, Filing 1, Brush Creek Village Subdivision. The permit and record drawing were provided by Pitkin County Environmental Health Department (Parcel ID #2643-213-07-006). The subject OWTS consists of one 1000-gallon, two-compartment poly Norwesco® septic tank followed by a dosing siphon in a separate chamber. Effluent is dosed to four SB- 2 trenches (minimum 550 linear feet). Individual Sewage Disposal System Permit 87025 documents this system. The system was sized to accommodate 3 bedrooms. The permit received final approval on August 5, 1987. The septic tanks are located off the eastern corner of the residence. A clean out was present between the house and septic tank. One manhole lid on the septic tank was just below grade. Both inlet and outlet tees were present. The mid tank baffle was present and appeared to be in good condition, separating solids and liquids in each compartment. The level in the septic tank appeared slightly high prior to pumping. It was later determined the high level was likely due to the pipe from the septic tank to the dosing chamber not having enough fall. The septic tank was pumped at the time of our inspection on April 10, 2019 by Altitude Septic. The dosing siphon was not accessible at the time of our first visit. Additional work was done to uncover the chamber and we returned on April 17, 2019. The manhole lid was approximately 3.5-feet below grade. The top of the chamber was tilted, and the siphon inside the chamber was also tilted. We added water via a garden hose and did not get the siphon to activate. Altitude Septic returned and pumped the tank and attempted to repair the siphon; however, the chamber was damaged, and a repair was not feasible. A replacement of the siphon and chamber is required. We walked the approximate STA at the time of both site visits. The STA is comprised of four separate SB-2 trenches, each with different lengths. It is possible they could be connected via drop boxes, but Pitkin County documents do not make that clear. No inspection ports were present at the time of our site visits. We walked the cleared area and found no evidence of surface saturation or failure at the time of our inspections. This evaluation is not a guarantee of future system performance. This inspection is good for one year. Required Repairs: • Install new dosing chamber and siphon. We have provided recommend chamber and siphon specifications. While the original dosing siphon had a 172 gallon dose, we recommend a smaller dose (95 gallons). Installation of the new chamber and dosing siphon must be done by a Pitkin County Licensed Systems Installer. An OWTS Construction Permit Application (tank only) must be submitted to the Pitkin County Environmental Health Department. Applications must be submitted to Pitkin County Environmental Health Department electronically. The following is the link to the required OWTS Construction Permit Application: https://pitkincounty.com/FormCenter/Environmental-Health-18/Septic-OWTS-ConstructionRepair-Permit- Ap-72 All questions regarding permit submission can be directed to Pitkin County Environmental Health Department, 970-920-5070. Disclaimer: This inspection is intended only as an evaluation of the present condition of the OWTS based upon what was observed and the Licensed Inspector’s expertise in onsite wastewater technology. The Inspector has not been retained to warrant or guarantee the proper functioning of the system for any period of time in the future. Because of numerous factors which may affect the operation of an OWTS, as well as the inability of the Inspector to supervise or monitor the use or maintenance of this OWTS, this report shall not be construed as a warranty by the Inspector that the system will function properly for any particular prospective buyer, and the Inspector disclaims any warranty, either expressed or implied, arising from the inspection of the OWTS or this report. The evaluation does not ascertain the impact the system is having on groundwater. Please call with questions. Sincerely, Carla Ostberg, MPH, REHS NAWT Certified Inspector Certification # 11044ITC Exp. April 2020 Clean out pipes Access to septic tank (only one access) mid tank baffle in poly tank Inlet tee outlet tee (water level too high) Baffle pumping tank Inside of tank (integrity of septic tank appears to be good) Looking toward STA from septic tank approx. STA Looking up from STA toward septic tanks Lid to dosing siphon Pipe from septic tank to dosing siphon pipe between tanks was flat (resulting in high level) Level in the siphon chamber filling with water Access to siphon 3.5-feet below grade Lid angled / siphon angled 2&y3-2 13 —0?- 006. ASPEN40PITKIN ENVIRONMENTAL HEALTH DEPARTMENT Agent_ Mailing Address Phone Sewage Disposal System Work to be performed by CCONr)e '" Pf%% 6ViHlgeV/A& This permit va id only for, premises location by tho following legal descriptions br L//u G j S yPjf- LOT SIZE =eK' WATER SUPPLY LLL AVERAGE PERCOLATION RATF. J This Individual Sewage Disposal Permit is granted with regard to the following use: & C>1'6 ma Ntrahcr oft Dodicoms _' Lofts _ Garbage Disposals/ / Dishwashers Washers CALCULATED AVERAGE DAILY WASTE LOAD J GALLONS. THE NATUP.E OF THE SYSTEM INCLUDED UNDER THIS PERMIT: Typa :if Tank or Treatment Unitt E L' 1/1 J Tank Capa/¢ity Ur'C/ Callon Minix,= M.cthod of Final Disposals `Q G/©IJ A f"TE I Absorptiop Area /i Square Feet Mintmum Description (including brand names, if any) of other equipment or appurtnaneess Other Conditions or Speciticationas Cl E , /GDk00C:F1&Al .7D 13.2 v . Fi: (,-2.,,V, ./ Y V F SEPT/ g'6RPT7 AJ SYSiE/UJ' /S c 1>. TALES REQUIRING INSPECTION BY THE HEALTH DEPARTMENT: nc•fore Excavation ( )Upon completion of excavation and prior to placement of gravel 01 sss nefore covering distribution Kr y / system of absorption field Pror to backfill of any component ( )Other, Specifyi Plans and specifications of the proposed sewage disposal system have been reviewed and are considered satisfactory. Perninrion is hcrcl:y granted to tLc owner or his agent to perform the work indicated above in accordance with the Pitkin County Indivi ual Sewa;e Disposal Regulations in effect on the date of issue. In addition to general provisions set forth on the reverse hereof, this Parmit is subject to the following additional terms and conditions: APPROVED FOR ISSUE BY (title) O% The abt, ve individual sc%.ra')o disposal sy+tem inatallcd by QWN15/e —4'q I has been ln:gicctcd for use by a representative (;f the Asl:en Pit in Lnvironfr nta responsibility in Casc of faalure or inadequacy of the sy'wa.)c disposal 841tefi. D?`iTE 01 INIAL IPiST.'E ION4z P By f '/ j ' r _ _ .; l• v.SLY [ G,{ Imo' : N^ 1 11calth Department. The uwnor asau.:.oa aid compl/eto as -built drawing attached. 130 South Galena Street Aspen, Colorado 81611 • 303/925-2020 SEWAGE DISPOSAL PER21IT N0. INDIVIDUAL OF PERMIT: TY/PE MiM(Initial Construction Emergency Use ( )Repair Work,(Pieviou• Permit 1 .) ( )Alteration of an existing system, installation Previous Permit 1 ? Use Permit as a result of sale Othort ISSUED TO: T0: DATE OF ISSUE , Owner . Am Home Phone/S' Business Phone Mailing CJ. Dol clq Aspa),00nt AddressY l h Agent_ Mailing Address Phone Sewage Disposal System Work to be performed by CCONr)e '" Pf%% 6ViHlgeV/A& This permit va id only for, premises location by tho following legal descriptions br L//u G j S yPjf- LOT SIZE =eK' WATER SUPPLY LLL AVERAGE PERCOLATION RATF. J This Individual Sewage Disposal Permit is granted with regard to the following use: & C>1'6 ma Ntrahcr oft Dodicoms _' Lofts _ Garbage Disposals/ / Dishwashers Washers CALCULATED AVERAGE DAILY WASTE LOAD J GALLONS. THE NATUP.E OF THE SYSTEM INCLUDED UNDER THIS PERMIT: Typa :if Tank or Treatment Unitt E L' 1/1 J Tank Capa/¢ity Ur'C/ Callon Minix,= M.cthod of Final Disposals `Q G/©IJ A f"TE I Absorptiop Area /i Square Feet Mintmum Description (including brand names, if any) of other equipment or appurtnaneess Other Conditions or Speciticationas Cl E , /GDk00C:F1&Al .7D 13.2 v . Fi: (,-2.,,V, ./ Y V F SEPT/ g'6RPT7 AJ SYSiE/UJ' /S c 1>. TALES REQUIRING INSPECTION BY THE HEALTH DEPARTMENT: nc•fore Excavation ( )Upon completion of excavation and prior to placement of gravel 01 sss nefore covering distribution Kr y / system of absorption field Pror to backfill of any component ( )Other, Specifyi Plans and specifications of the proposed sewage disposal system have been reviewed and are considered satisfactory. Perninrion is hcrcl:y granted to tLc owner or his agent to perform the work indicated above in accordance with the Pitkin County Indivi ual Sewa;e Disposal Regulations in effect on the date of issue. In addition to general provisions set forth on the reverse hereof, this Parmit is subject to the following additional terms and conditions: APPROVED FOR ISSUE BY (title) O% The abt, ve individual sc%.ra')o disposal sy+tem inatallcd by QWN15/e —4'q I has been ln:gicctcd for use by a representative (;f the Asl:en Pit in Lnvironfr nta responsibility in Casc of faalure or inadequacy of the sy'wa.)c disposal 841tefi. D?`iTE 01 INIAL IPiST.'E ION4z P By f '/ j ' r _ _ .; l• v.SLY [ G,{ Imo' : N^ 1 11calth Department. The uwnor asau.:.oa aid compl/eto as -built drawing attached. 130 South Galena Street Aspen, Colorado 81611 • 303/925-2020 ft ?- -21 a ASPEN*PITKIN ENVIRONMENTAL HEALTH DEPARTMENT Legal decription: FIELD TEST DATA SHEET Name of Owner: l Address: st. / p.o. box) (city) (state) (zip) Name of Agent: Water Supply: Public Utility Subdivision Private Well , Lot Area: Distance to Nearest Surface Waterj.t,. Dates Observations Made: Soil Borings: 1.1lq by Percolation Tests: d by SOIL BORING TESTS ft. PERCOLATION TESTS AT DEPTH TO SROVND —'CR. TL[T N. TCST Y6 NVML[D TOTAL DEPTH T OBSERVED ESTIMATED NIGCHARACTER OF SOIL 'IT' TNICRN[[! IN /[[T HkC LASTTESTOCTM TO FALL UMBER INCHES THICKNESS IN INCHES IST NET OVERNIGHT IN MINUTES X•. LAST PERIOD PERIOD ONE INCH P-1 B+ - 2 F` gg Cgg Ogg Cg Ai 9A SOC PR £2 g ( ` y 7ft 7R 7R SOC 702 7TC g } ( Ri FR A 0 j ( g j }yj ( } j g gyp{ y ` } y ( y Sp ( yy A g A A AR SR g SR g g YR 7& SR fA R2 PR R4 SR g £t 3a N•: t PERCOLATION TESTS Average Rate: _,?4 minutes/inch Plan of the site on the back Date Signature BIOS NELSON ASPEN/PITKIN SANITARIAN 130 S. GALENA ASPEN, CO 81611 RsHONWATER TEST TIME DROP IN WATER LEVEL. INCHES MINVTES SECOND TO NEAT TO LASTTESTOCTMCNARACTEROFSOILSINCENOINHO}C IN TCRVAL TO FALL UMBER INCHES THICKNESS IN INCHES IST NET OVERNIGHT IN MINUTES LAST PERIOD LAST PERIOD PERIOD ONE INCH P-1 n 0 P-2 2y q fl 2 Z„ P-3 d P-4 r Average Rate: _,?4 minutes/inch Plan of the site on the back Date Signature BIOS NELSON ASPEN/PITKIN SANITARIAN 130 S. GALENA ASPEN, CO 81611 ASPEN*PITKIN 0 ENVIRONMENTAL HEALTH DEPARTMENT FIELD TEST DATA SHEET Legal decription: Name of Owner: Cav, A Address: 4.O 0 L Z- St. / P. 0. box) (city) (state) (zip) Name of Agent: Water Supply: Public Utility Subdivision Private Well Lot Area: 'Zoi OA-- Distance to Nearest Surface Water ft. Dates Observations Made: Soil Borings: by Percolation Tests: by &F' If SOIL BORING TESTS TEST TOTAL OCPDV TN TO GROUND WATER. TELT TN 4S NUM![A T[[T OSILRV[D ESTIMATED NIGH CHARACTER OT SOIL WITH TNICRN[SS IN •[[T iR $x N B-1 B-2 PERCOLATION TESTS Average Rate: 12.9 minutes/inch Plan of the site on the back _ Date Signature 4,II........., BIOS NELSON ASPEN/PITKIN SANITARIAN 130 S. GALENA ASPEN, CO 81611 NO 1RS WATER DROP IN WATLA LEVEL. INCHES TEST TIME MINUTES TEST DEPTH CHARACTER O. TOIL SINCE NO 1N HOLE 1N T[RVAL SECOND TO M[iT TO LAST TO /All M UMBER INCHES THICKNESS IN INCHES J!T WCT OVERNIGHT N MINUTE LAST PERIOD LAST PERIOD PERIOD OM[ INCH P-1 Z r Y P-2'47, Z/07. Z P-3' 11-T l2.13 P-4 Average Rate: 12.9 minutes/inch Plan of the site on the back _ Date Signature 4,II........., BIOS NELSON ASPEN/PITKIN SANITARIAN 130 S. GALENA ASPEN, CO 81611 t 0 I , ASPEN#PITKIN ENVIRONMENTAL HEALTH DEPARTMENT FIELD TEST DATA SHEET Legal decription: Zj-4 6" ..7 ` Name of Ot4ner: Address: st. / p.q. box) Name of Agent: A4 w6/a. cit (state) (zip) Water Supply: Public Utility Subdivision Private Well 114 ten- Lot Area: A, Distance to Nearest Surface Water, ft. Dates Observations Made: Soil Borings: 4 by Percolation Tests: ?by XF—d SOIL BORING TESTS M 4: } x*'. DEPTH TO GROUND WATER, EGET TEST TOTAL DEPTH \. lQS MUM\[11 FELT OS]CAv[D [STIMAT[O NIGH CHARACTER 01 SOIL WITH TNIC«NESS IN /[[T fR ti Sat B—Z A. X B-2 n: r> PERCOLATION TESTS Average Rate: minutes/inch Plan of th site on the back Date Signature ; BM NELSON ASPEN/PITKIN SANITARIAN 130 S. GALENA ASPEN, CO 81611 11111 11111K9 NOVR] DROP IN WATER LEVEL. INC"[* WATER TEST E'IMC MI.UT[S TEST I DCP,I I CHARACTER OF SOIL I SIN CC NO IN NO.LE INTERVAL SECOND TO MEET TO LAST TO PALL NVM SC/l INCHES THICKNESS IN IN CNES 1ST WILT Oyf R.IG.T N MINUTE LAST PERIOD LAST CRIOD PERIOD ONE IN" C4P-1 P-2 Ow Z 3C i P-3 P-4 Average Rate: minutes/inch Plan of th site on the back Date Signature ; BM NELSON ASPEN/PITKIN SANITARIAN 130 S. GALENA ASPEN, CO 81611 0 9 2 4 ADS, Inc. Drainage Handbook Specifications ¨ 1-24 Ó ADS, Inc., February 2017 ADS SB2® PIPE SPECIFICATION Scope This specification describes ADS SB2 pipe available in 8- and 10-inch (200 and 250 mm) diameters for use in on-site waste disposal applications. Pipe Requirements ADS SB2 pipe shall have a corrugated interior and corrugated exterior a pre-installed septic fabric. · 8- and 10-inch (200 and 250 mm) pipe shall meet the requirements of ASTM F667. · There shall be two ½ inch (12.7 mm) holes 120 degrees apart on the length of the pipe. · The 8-inch (200 mm) and 10-inch (250mm) pipe shall have 1.0 square inches per foot of open area. Joint Performance Pipe shall be joined with internal or external snap couplers covering at least two full corrugations on each end of the pipe. Fittings Fittings shall conform to ASTM F667. Material Properties Pipe material shall be high density polyethylene conforming with the minimum requirements of cell classification 424410C as defined and described in the latest version of ASTM D3350; or ASTM D1248 Type III, Class C, Category 4, Grade P33. Filter Fabric Properties Material Nylon (100%) Fabric Spun Bond Fiber Size (denier per filament) 5 Weight (ounces per yd2, ASTM D3776) 0.85 Burst Strength (pounds per in2, ASTM D3786) 28 Air Permeability (CFM per ft2, ASTM D737) 650 Equivalent Opening Size (Army Corps of Engineers, W 02215) 50 Water Flow Rate (gal/min/ft2, ASTM D4491) 163 Melt Temperature (ASTM D3786) 218˚ C (425˚ F) Installation Installation shall be in accordance with ADS recommended installation instructions and those issued by a local health department. For leachfield applications, installation shall be in accordance with ASTM F481 and as regulated by regional, state, and local agencies. Proper authorization for specific applications and designs should be obtained prior to installation to ensure suitability in certain locales. Contact your local ADS representative or visit our website at www.ads-pipe.com for a copy of the installation guidelines.