HomeMy WebLinkAboutPitkin.EH.246720101001 (2018)Pitkin County Environmental Health Department
Onsite Wastewater Treatment System (OWTS) USE PERMIT
Permit for Continued Use of an Existing OWTS
76 Service Center Road, Aspen, CO 81611
Phone: 970-920-5070 Fax: 970-920-5077
www.aspenpitkin.com/EHNR
Parcel ID #: 2467-201-01-001
OWTS Use Permit #: 0031.2018.POWU
Date Issued: 7/5/2018
Issued By: Bryan Daugherty
Expiration Date: 7/5/2019
Owner(s): Monrow George and Glenda Gayle Summers
Property Address: 88 Hollands Hills
Legal Description:
Licensed Inspector: Carla Ostberg
Inspection Date(s): 4/23/18 & 4/27/18
SYSTEM INFORMATION
Components Type Capacity/Size
Primary Treatment Unit 2 compartment concrete tank
2 compartment concrete tank
1000 Gallons
1000 Gallons
Secondary Treatment Unit
Absorption Area Dry Well x2 12’x12’x10’
Other System Components Bull Run Valve
In use at the time of the inspection. Not in use at the time of the inspection.*
*If the OWTS was not in use at the time of the inspection, it is recommended that the system be re -evaluated when it is in use for a more accurate
evaluation of the system.
System Records:
Permit #: 95021 & 76079 Date of Issuance: 1/29/96 Date of Final Approval: 10/2/96
# of Bedrooms or fixtures served by OWTS: System was designed for 6 bedrooms, floor plans show 5 bedrooms in the
home.
Operational Status: After repairs were made to the system, it appeared to functioning as designed. Sewer lines were
replaced on the 1976 tank and an outlet tee was replaced. Risers were added to the 1995 tank to bring access to grade.
Bull Run valve was repaired and is functional. Tanks were in good water-tight condition, the dry wells did not have an
signs of failure such as surfacing effluent.
Inspector Recommendations: Clean filters annually
Department Recommendations: Annual maintenance
Issuance of this OWTS Use Permit is based solely on the conditions observed and reported by the inspector to the Department on the date of the inspection(s) and
on Department records at the time of permitting. The issuance of this permit does not constitute a guarantee, warranty, or representation by the Department
that the system will operate properly or will not fail or that the system will not be subject to future enforcement action to correct non-compliant conditions.
Estimated capacity of the system has been listed on the permit and we recommend that you monitor and/or meter water use to prevent overuse and possible
failure.
"
0-
ON
i,x, K I N Onsite Wastewater Treatment Systems (OWTS) Use
Permit Inspection Form
""'COUNT Pitkin County Environmental Health Department
76 Service Center Rd, Aspen, CO 81611
Phone:970-920-5070 Fax: 970-920-5374
Website: I http://pitkincounty.com/248[Wastewater-Treatment
Inspection form for continued use of an existing OWTS
Owner's Name:
Address:
Parcel Number:
Inspection Date:
Inspector's Name:
Business Name:
Phone Number
Email:
Pitkin County Systems
Monroe Geor e and Glenda Gayle Summers
88 Holland Hills Road
Basalt CO
2467 201 01 001
A ril 23 & 27 2018
Carla Ostber
CBO Inc.
(970) 309-5259
carla.ostberg@gmail.com
Inspector License Number:
1017
A copy of this inspection report will be remitted to Pitkin Countv Environmental Health Department b
the Licensed Systems Inspector within 60 days of the inspection regardless of whether the system
passes or fails.
QUESTIONS FOR PROPERTY OWNER PRIOR TO INSPECTION:
Is the home currently occupied? EYES ❑NO
If NO, how long has the home been vacant? assessor's records
How many bedrooms are in the home? 14 show 4 bedrooms
If secondary treatment is used, who is the
maintenance provider? I n/a
RECORDS:
Were system records available from Pitkin County? EYES
❑NO
Permits 76079
'
If YES: Permit number: 1
92050, and 95021
Date of Final Approval: October 2, 1996
# of bedrooms permitted:
Was an as -built drawing available? E YES
❑ NO
Is the as -built drawing accurate? ❑YES
❑NO
If NO: Complete a drawing of the system on last page of
this form as accurately as
possible.
Any question marked FAIL will require correction before an OWTS Use permit is issued.
SITE CONDITIONS:
Proper grading, no evidence of erosion?
EPASS
❑FAIL
Improper vegetative cover?
0
NO
❑
YES
Evidence of compaction such as heavy machinery or livestock?
0
NO
❑
YES
Improper discharges such as straight pipes?
❑'
PASS
❑FAIL
possible infiltration
Evidence of high ground water?
❑
NO
M
YES
of ditch into
Snow cover present?
❑ NO
❑ YES
seepage pit(s)
Page 1 Effective Date 1/12/2017
1976 1996 ::]
TANK:
Tank 1
Tank 2
Tank 3
Tank capacity
1,000
=gallons
1,000 j
gallons
gallons
Tank material
concrete
concrete
# of compartments
2
2
Date of last pumping
April 23, 207 (B&R)
May 2018 (Altitude)
Lids/risers in good condition
Pass
Pass
Select One
Risers to grade
Yes
Yes
Select One
Riser height
2'
2'
Riser condition/watertightness
ok
ok
Inlet sanitary T/baffle
Pass
Pass
Select One
Outlet sanitary T/baffle
Pass
Pass
Select One
Effluent filter (if part of design)
N/A
N/A
select One
Condition of tank material
Pass
Pass
Select One
Tank was pumped for inspection
Yes
Yes
Select One
If YES, list the pumping company
B&R
Altitude
If NO, when was the last pumping
Scum level (1st compartment)
inches
inches
inches
Sludge level (1st compartment)
inches
inches
inches
Scum level (2nd compartment)
inches
inches
inches
Sludge level (2nd compartment)
inches
inches
inches
Backflow (if pumped)
Pass
Pass
Select One
Midtank baffle
Pass
IPass
Select One
Watertightness
IPass
IPass
ISelect One
PUMPS/DOSING SIPHONS:
Is a pump or dosing siphon present? ❑ YES NO
If YES, is the pump/dosing siphon functioning properly? ❑PASS ❑FAIL
Does the pump/wiring/dosing siphon appear to be in good condition? ❑PASS ❑FAIL
Is the high water alarm working, both visible and audible? ❑PASS ❑FAIL
SECONDARY TREATMENT:
Is a secondary treatment unit present? ❑YES 0 NO ❑UNKNOWN
If YES, does the unit appear to be in good working condition? YES NO
Does the owner have a current maintenance contract for the unit? YES H NO ❑UNKNOWN
Maintenance Provider: n/a Phone:
If there is no maintenance contract, a contract must be in place prior to occupancy of the home. A
copy of the contract must be submitted to Pitkin County Environmental Health Department.
ABSORBTION AREA:
Effluent surfacing?
Evidence of past surfacing?
Surface dampness?
Excessive odors?
Field location verified by observation ports or probing:
Liquid in observation port?
If YES, record depth:
Distribution Box or ADV part of original design?
If YES, is it accessible from grade?
Is it level and in good condition?
❑�
PASS
❑FAIL
E
NO
❑YES
F.
NO
❑
YES
❑�
NO
❑
YES
❑Ports [--]Probing
NO ❑ YES
inches
❑ YES ❑ NO
YES NO
PASS FAIL
access to 1976 seepage pit
camera located 1992 seepage pit
UNKNOWN
Page 2
Effective Date 1/12/2017
The ditch had just been turned on and was saturating areas below, including driveway. Water
levels in the 1976 seepage pit were at 3'. In order to determine of the ditch is influencing levels in
the seepage pit, levels should be monitored throughout the year when the ditch is both on and off.
'lease list any recommendations for the continued use of the system:
see "additional notes"
Were any repairs done as a result of this inspection? ❑ NO ❑ YES
If YES lease describe the repairs.
• Pumped 1976 septic tank.
• Replaced outlet tee on 1976 septic tank.
• Replaced sewer line from 1976 septic tank to 1976 seepage pit.
• Uncovered lids to 1995 septic tank and added risers to make the lids accessible from grade.
• Repaired Bull Run Valve so it is functional.
To the best of my knowledge and training, the information collected in this inspection is accurate as of
June 11 1, Zp 18
barg
Licensed Systems Inspector Signature: Carla Ostber Digitally18.06.ned byC:57:51arla [06'0
Y p g g Date: 2018.06.110757:51 O6'00'
Additional Notes:
• Consider containment of ditch as it is likely infiltrating into seepage pits. Verification will require
additional monitoring at different times of the year.
• Monitor condition of 1976 septic tank.
• Add effluent filters to outlet tees of septic tanks. If added, the effluent filters must be cleaned
annually, or as needed.
Clearly label any pictures and attach them to this form.
Save Form Clear Form
Print Form
Page 3 Effective Date 1/12/2017
CBO Inc.
33 Four Wheel Drive Road
Carbondale, CO 81623
cell) 970-309-5259 office) 970-704-0484
carla.ostberg(@gmail.com
June 9, 2018
Glenda Summers
moglen(cDcomcast. net
Onsite Wastewater Treatment System (OWTS) Use Permit Inspection
88 Holland Hills Road
Pitkin County, Colorado
Glenda,
As requested, CBO Inc. performed an Onsite Wastewater Treatment System (OWTS) Use Permit
inspection at 88 Holland Hills Road, Basalt, Colorado on April 23 and April 27, 2018. The legal
description of the 1.2-acre property is Lot 16, Holland Hills at Basalt Subdivision.
The permits and record drawings were provided by Pitkin County Environmental Health Department
(Parcel ID #2467-201-01-001). The subject OWTS consists of one 1000-gallon, two -compartment
concrete septic tank followed by a drywell, or seepage pit, with dimensions of 12' x 12' x 10' below the
inlet. This system served the original portion of the house. Pitkin County Health Department Permit
Number 76079 documents the system. The system was sized to accommodate a 3-bedroom residence.
In 1992, an additional drywell, or seepage pit, was added with a Bull Run valve for alternating. The
dimensions of the new seepage pit are 12' x 12' x 10' below the inlet. Individual Sewage Disposal
System Permit 92050 documents this addition. The system was sized to accommodate 3 bedrooms.
The permit received final approval on August 11, 1992.
In 1995, an addition to the system was permitted to accommodate additional bedrooms and living area.
A new 1000-gallon, two -compartment septic tank was added to the existing system. Individual Sewage
Disposal System Permit 95021 documents this addition. The system was sized to accommodate 6
bedrooms. The permit received final approval on October 2, 1996.
The 1976 portion of the system serves the original section of the residence. The septic tank is located
west of this portion of the residence. Both septic tank lids are accessible from grade. There is no clean
out between the house and the septic tank. Given the age, it is possible the sewer line from the house to
the septic tank is cast iron or clay. The inlet tee is made of clay. The outlet was PVC but was not
installed well and was cracked. Levels in the septic tank were normal to slightly over -full. Solids in the
septic tank warranted pumping.
On April 27, 2018 Altitude Septic ran a camera through the sewer line from the septic tank to the
seepage pit and it was found to be clogged and in disrepair. The Bull Run Valve was not operational at
the time our inspection. The seepage pit had 3-feet of water at the time of our April 23, 2018 inspection.
We measured 6 to 7' from the bottom of the seepage pit to the inlet pipe, which is inconsistent with the
depth of 10' stated in the permitting documents.
At the time of our visits, the ditch had just been turned on and we believe the water levels in the seepage
pit is likely being influenced by the ditch, although greater than 50-feet away. We recommend
considering lining or placing this ditch in a culvert. This may be difficult due to the existence of a pond.
This recommendation may require additional monitoring of levels in the seepage pit at different times of
the year to verify if the ditch is in fact influencing the seepage pit(s).
During our April 27, 2018 visit with Altitude Septic, they located and uncovered the 1992 septic tank.
Solids in the septic tank warranted pumping. A camera was run from the 1992 septic tank to the 1996
seepage pit. The line was found to be in good condition. There was no access to the 1996 seepage pit;
therefore, we were unable to evaluate the condition of seepage pit.
Altitude Septic replaced the sewer line from the 1976 septic tank to the 1976 seepage pit, pumped the
1976 septic tank, replaced outlet tee on 1976 septic tank, replaced sewer line from 1976 septic tank to
1976 seepage pit, uncovered lids to 1995 septic tank and added risers to make the lids accessible from
grade, and repaired Bull Run Valve so it is functional. If future rotation of the Bull Run Valve (to switch
seepage pits from the 1976 seepage pit to the 1996 seepage pit) is desired, this must be documented
and maintained for future reference.
Repairs Conducted:
• Pumped 1976 septic tank.
• Replaced outlet tee on 1976 septic tank.
• Replaced sewer line from 1976 septic tank to 1976 seepage pit.
• Uncovered lids to 1995 septic tank and added risers to make the lids accessible from grade.
• Repaired Bull Run Valve so it is functional.
Recommendations:
Consider containment of ditch as it is likely infiltrating into seepage pits. Verification will require
additional monitoring at different times of the year.
Monitor condition of 1976 septic tank.
Add effluent filters to outlet tees of septic tanks. If added, the effluent filters must be cleaned
annually, or as needed.
This report and a completed OWTS Use Permit Application must be submitted to the Pitkin County
Environmental Health Department. Applications may be submitted to Pitkin County Environmental Health
Department electronically. The following are links to the required OWTS Use Permit Application and
Checklist.
Application: htti)://www.i)itkincounty.com/DocumentCenter/HomeNiew/621
Application Checklist: httr)://www.i)itkincounty.com/DocumentCenter/Home/View/620
All questions regarding permit submission can be directed to Pitkin County Environmental Health
Department, 970-920-5070.
Disclaimer: This inspection is intended only as an evaluation of the present condition of the OWTS
based upon what was observed and the Licensed Inspector's expertise in onsite wastewater technology.
The Inspector has not been retained to warrant or guarantee the proper functioning of the system for any
period of time in the future. Because of numerous factors which may affect the operation of an OWTS,
as well as the inability of the Inspector to supervise or monitor the use or maintenance of this OWTS, this
report shall not be construed as a warranty by the Inspector that the system will function properly for any
particular prospective buyer, and the Inspector disclaims any warranty, either expressed or implied,
arising from the inspection of the OWTS or this report. The evaluation does not ascertain the impact the
system is having on groundwater.
Please call with questions.
Sincerely,
Carla Ostberg, MPH, REHS
NAWT Certified Inspector
Certification # 110441TC Exp. April 2018
f -
Y' F
-34
View of 1976 OWTS / arrow points to seepage pit 1976 septic tank
Clay inlet tee
outlet tee
I
Septic tank is aging and showing signs of deterioration
Seepage pit (3' of water in bottom)
Ditch runs to north side of property
Saturation of driveway below ditch
pond created by ditch
mat
View of outlet side of 1976 tank after tee was removed Inlet line to 1976 seepage pit (note sludge)
Outlet tee / note crack
Access to Bull Run Valve
'll
Pumping 1992 septic tank
16
Bull Run valve
i
s? +i
VO
ti
1992 septic tank after being located and dug up
Repairs
New outlet tee 1976 septic tank
Replacement ofsewer line between 1790septic tank and 1976seepage pit
New risers on 1992 septic tank
cast iron lids in driveway
i- OL C�
}G(Y-t Qc-f - Pr
-wry
1
.�O
I'
C
c��
r
l 441
Ault
V V
SUMMERS
PROPERTIES WEST, INC
MANAGEMENT
MAINTENANCE
LEASING
SALES
P.O. Box 12047
Aspen, Colorado 81612
(303)925-4446
M-l'
January 25, 1996
0
Betsy Kipp
Environmental Health Department
130 S. Galena Street
Aspen, CO 81611
RE: New Septic Tank
88 Holland Hills Road
Dear Betsy,
J A N 2 91996
n*ieeTA HEALTH
ASPEN 1 PITKEN
Pursuant to our recent discussions. My Architect and Plumbing consultant
both advise me that the only logical physical approach to my need to add
additional septic capacity is to install the new 1,000 Gal tank in the driveway,
with a reinforced roof, and connect it to the second dry well. This approach
is outlined on the attached sketch.
In my estimation, the flow would be approximately equal to both. The
original septic tank would still serve the two original bathrooms. The New
septic tank would serve the new master bath and the remodeled kitchen.
The current plan calls for relocating the washer and dryer to the new
upstairs pantry which could also be served by the new septic tank.
Physical logistics and existing site restrictions make connecting the two tanks
and getting the sewer from the new addition back into the old system a
daunting task. Hopefully you can approve this approach as originally
discussed and send me a brief note evidencing same. Please call me if you
need any additional information.
Thank you in advance.
Sincere
Mo oe G.
t C.
��
1440 5Cp FT
6�)50 40L)
AXIS ��
c� ;
s� c
y
r
10�,t�
0
&CL4 ' I, ODD C4L
G7-oP6L[ t) St f
�UT
I
�T s
Pitkin County Environmental Health Department
j-f KIN Onsite Wastewater Treatment System (OWTS)
COUNTUS
E PERMIT APPLICATION
76 Service Center Rd
Aspen, CO 81611
http://pitkincounty.com/248/Wastewater-Treatment
Application for Continued Use of an Existing OWTS
Parcel ID# (available from the Pitkin County Assessor's Office
2467 201 01 001
970-920-5160 or atF—http://pitkinassessor.org/assessor/search.asp
Purpose of Use Permit: PROPERTY TRANSACTION
REMODEL/
Property Address:
88 Holland Hills Road
Lot:
Block:
Filing:
Subdivision:
16
Holland Hills at Basalt
Residences:
I Other
apartment (2 bedrooms)
# of Bedrooms:
3 fixtures/uses:
Property Owner(s)':
Email Address:
Monroe George & Glenda Gayle Summers
moglen@comcast.net
Owner's Mailing Address:
City, State, Zip:
88 Holland Hills Road
Basalt
CO
81623
Home Phone:
Business Phone:
(970) 618-5286
*Contact information must be provided for the owner signing this application.
Primary Contact Person/Applicant (if not owner):
Company:
Contact/Applicant Mailing Address:
City, State, Zip:
Cell Phone:
Business Phone:
Fax Number:
Email Address:
carla.ostberg@gmail.com
Indicate Preferred Method of Payment
Check 1 ■ Credit/Debit r7 Cash
Licensed Systems Inspector: Phone Number: Email Address: Fax Number:
Carla Ostberg
(970) 309-5259
carla.ostberg@gmail.com 11
Mailing Address: City, State, Zip:
33 Four Wheel Drive Road
Icarbondale
jC0
181623
PLEASE READ BEFORE SIGNING:
I certify that the above information is complete and accurate and that I have provided complete and accurate information in all of the documents
included in my application package. I acknowledge that this department may revoke any permit I am issued if my application is found to contain any
inaccurate, false, or misleading information.
Owner Signature (Required):
Digitally signed by Glenda G. Summers
Glenda G. Summers Date: 2018.06.2309:02:14-06'00'
Date:
Applicant Signature:
Digitally signed by Carla Ostberg
Carla Ostberg
Date:
6/22/18
Date: 2018.06.2211:31:23 06'00'
Please allow 3-5 business days for processing of Use Permits. Save Form Clear Form Print Form
FOR OFFICE USE ONLY
Received by EH Staff:
Fee & Receipt #: Date:
Effective Date 1/12/2017